Loading...
HomeMy WebLinkAboutARVESON LT 8  flUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT IPHONE I []NEW NAM 'z/'R Y ,J' E Z 0 7T ZUP "ADE MAILING/ 7~/~ADDRESS ~ LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS I Well [ AbsorPtion area Dwelling PERMIT NO. DISTANCE TO: ~ Z Manufacturer Material ~ No, of compartments  Liq. capacity in gallons IF HOMEMADE: Inside length Width Liquid depth ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. O Z ~ Manufacturer Material Liquid capacity in gallons ~ DISTANCE TO: Well ~ Foundation Nearest lot line PERMIT NO. ~ No, of lines Length of~ach line Total length of lines Trench width Distance between lines  Top of tile to finish grade Material beneath tile Total effective absorption area Length Width Depth PERMIT NO, ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER REMARKS APPR OV E D DATE LEGAL 72-013 (Rev. 3/78) PERMIT NO. I ,3 I F'ALIT"T' ~]F ANCHORAGE DEPARTMENT ~' ~ALI'H AND ENVIRONMENTAL' 'ECTION 825 ~ JTREET~ ANCHORAGE~ AK. 264-4728 Ot~--SITE SELdER PERMIT 800251 ) APPLICANT LOCATION LEGAL GARY MELLOTT SHADY LANE L8 ARVESON SUBDIVISON i741-M SRA LOT SIZE ~49-~70 10000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS SOIL RATING (SQ FT?BR)= 100 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: [)EPTH= l[~ LENGTH= ~4 GRAVEL DEPTH= 4. 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF 8 TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). REQLI I RED SEPT I C TANK PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLHTION INSPECTIONS OF 8NY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. THO ( 2 > INSPECT IONS ARE REQU I RED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM 8 PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THAT l: I 8M FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS. SIGNED: RPPL I C RNT~R~Y ~ELLOTT PERFORMED FOR= dAT~ v CONTRACTIN %'ENt INE I S & ASSOC. 212 E. INTE~TIONAL ~I~PORT ROAD ANC~GE, ALASka99502 P~O N E ~ ~ b L~ DATE PERFORMED: ,'~ SOILS LOG PERCOLATION TEST LEGAL DESCRIPTION: SLOPE SITE PLAN , I COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? O P E Reading Date Gross ~ Net Depth tO ~ Net Time Time Water Drop ~1~O LATIO N RATE (minutes/inch) ' TEST RUN BETWEEN FT AND FT -/~ / . PERFORMED BY: (~,~'~1,~ ~ CERTIFIED BY: ~~'"'-'-- DATE: ~/,~ ,~d.~ GRE ' ANCHORAGE AREA BOR" Department of Environmental Quality 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION MAILING ADDRESS ~' /~A%'~¢7~ .~/". LEGAL DESCRIPTION PHONE z. Ol- ,~ ~e~o, SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH ~-~0) MANUFACTURER~.~P(b:~<~ ~f~'~/-,--/~O. MATERIAL~/-T¢' /'</~;<~..'~ i NUMBER OF COMPARTMENTS INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY. /<9Od) GALLONS. SEEPAGE PIT: NUMBER OF PITS / LINING MATERIAL ~17 ~t?.t~ BUILDING FOUNDATION~, ~0 ADDITIONAL ABSORPTION DIAMETER ___ OR WIDTH/~//~/¢ ' / bE N GT'/~-¢~- DEPTH ! CRIB SIZE: DIAMETE DEPTH ~, DISTANCE FROM: f f TOTAL EFFECTIVE NEAREST LOT LINE ~O ABSORPTION AREA (WALL AREA) .SQ. FT. WELL: TYPE p~(~/l~, _L~/¥~))b. CONSTRUCTION BUILDING NEAREST FOUNDATION __, LOT LINE CESSPOOL , OTHER SOURCES APPROVED DISAPPROVED DEPTH DISTANCE FROM: NEAREST SEPTIC SEEPAGE SEWER LINE TANK __., SYSTEM REMARKS DISTANCES: INSTALLED BY: ~¢g,i ~ PIPE MATERIAL: LOT SLOPE: REMARKS: ~-4er~r~ I-~ ~e__b ~ Form PW-026 DIAGRAM OF SYSTEM DATE ~-~?~Z-~ /¢] '?,~" APPROVED ~--r d ' ~ )~~ G.A.A.B. GREATER ANCHORAGE AREA BOROLIGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6.050 ANCHORAGE. ALASKA 99502 TELEPHONE 279-8§86 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO. - INSTALLATION LOCATION., ~ ¢ ~ ~ ~A ¢~: ~ ~0~ . INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT_ TYPE AND SIZE OF FACILITY TO BE SERVED ~~ ~ ~ ~ ~ ., ~ FINANCED THROUGH ~ ~ TO BE INSTALLED BY SOIL TEST RESULTS ~ ~ ~ ~T ~ I COMPLETION DATE ANTICIPATED /~ ~ ~ Z OTHER NOTE: THIS PERMIT I$ NOT VALID WITHOUT ~OIL TES? FINAL IN~,PECTION= 3~4 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE /g~ O 0 TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT 2 (~ DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SI~PTIC TANK ~'~ ~ ~ ~SEEPAGE PIT 2 0 ~ DRAIN FIELD TO NEAREST LOT LINE. WELL TO 5E~IC TANK ~ I ' SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. (o' DRAIN FIELD 70 RIVEE, LA~E. STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AN[') INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGe: PIT FtT'rED WITH AIRTIGHT REMOVABLE GRAVEL BACKFILL DIAGRAM OF SYBTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2B-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE DATE APPLICANT'S Stq~;NATURE .~ Performed For Le~ai Description. Lot ~ Block This ~'o[n, ..-,enorts Soils ~ TUDOR ROAD, ANCHORA(]m'. ALASKA 99507 · TELEPHONE 333-8472 GARY MALLOTT Date Performed Subdivision ARW~SON Percolation Test 9-18-72 nenth "eet Soil Characteristics Rpad*~ nq : Gross Time l Net - i me Percolation Rate Hinute Proposed Installation. SeeDaae Pit ;~: Drain Field Deoth of Inlet Depth 7o !~ottom Of Pit Or Trench CnM~ENTS · , ' __.,k]O s_9~. ft. drainage area re.?~i, red im~r~ bedroom No bedrock or water table ~'~ihi_n h £+. ~f bottom of seepage pit Depth to H 20 Ne~ Drop, i~ I~E'- ' INSPECTION APPOINTMENTS D~ '1 TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSPECTO. B MUNICIPALITY OF ANCHOP, AGE MUNICIPALITY OF ANCHORAGE DEPT. OF t!2ALTH &  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROT~NMENTAL FLOTECTION', 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANITATION DIVISION JU~ 2 O 1980 Telephone 264-4720 DEr E/~/EI't REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SE'~EI'IR~I[1/~I~ DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER ' ' I'PHONE MAI LFNG ADDRF~S ' PROPERTY R ESI I~ENT (If different from above) PHONE l'?r "l l e. J__ ' PHONE 2. 'BI,LYER , M~LING ADDRESS ' ~ - ~ , - ~ ~ ~ PHONE 4,' R~AL~OR/AGENT I PHONE' MAI LING AD D~ ESS t * I STREET L~CATION ' - 6, TYPE OF RESI~NC~ SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF~BEDROOMS [] One [] Four [] Two [] Five [~ Three [] Six [] Other 7. WATER SUPPLY ~ INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give wel depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ I NDIVI DUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] IN DIVI DUAL/ON -SITE []PUBLIC UTILITY Connection Verified []Septic Tank or [].Holding Tank Size:, //<:~(JO If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA [] ONE [] TWO PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER NUMBER OF BEDROOMS [] THREE [] FIVE [] FOUR [] SiX DATE INSTALLED INSTALLER SOl LS RATING IMANUFACTURER MATERIAL 4; DISTANCESwELL TO: Sept c/Hold ng Tank Absorption Area to nearest Lot Line IAbsorption Area [Sewer Line [] OTHER Nearest Lot Line 5. COMMENTS DATE [~/APPROVED FOR -'~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED BY 72-010 (Rev. 6/79) Municipality Ancho ag I)[ PAfVTiVtEN1 Ot: HI Al.lit AND EN\/I;-~ONMFNTAL PROTECTION 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 June 23, 1980 Gary Mellott % Orville F. Lamson 3250 East 68th Avenue Anchorage, Alaska 99507 Subject: Lot 8 Arveson Subdivision Approval for the individual sewer and water facilities can not be granted until the following items have been completed: (1.~ The water analysis report be delivered to this department from Chem Lab, 5633 B Street, for our review. (2) A four(4) inch cast iron cleanout needs to be installed to the septic tank. This will need to be re-inspected by 'this department. , (3) The septic tank pumped with a receipt submitted to _.~/O~this department. (4) An adequacy test be performed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. This report needs to be submitted to this department for o~ review. If there are any further questions, please call this d~partment at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw • (4...e Municipality of Anchora y6 a 9 �o '' °L, c On-Site Water and Wastewater Progra ti r,1� iil ' % milli f, V' (907) 343-7904 { JUN 13 '1018 'All E T Y Certificate of On-Site Systems Apo S al c� h zi Parcel I.D. 015-273-13 Expiration Dat0e:6 Bag��-1 3 1. GENERAL INFORMATION Complete legal description Arveson, Lot 8 Location (site address) 11131 Shady Lane Anchorage, AK 99516 Current Property owner(s) Jusdi McDonald & David Doucet Day phone Mailing address 11131 Shady Lane, Anchorage AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: H Single Family (w/wo ADU) I I Duplex Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Three 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well x Individual H Individual Water Storage ❑ Holding Tank ❑ Community Class Well H Community ❑ Public Water System 11 Public Sewer ❑ WaiverNariance request for: Distance: Received by: OA 067/(77 7772/`2/ / Date: (c'/ -9 //tri COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5a4,,, Waiver Fee $ Date of Payment 62!ab Che Date of Payment Receipt Number 0q0N9,q0 Receipt Number COSA# 0,4jC 1 vi a-f Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Forge Engineering Phone (907) 522-7773 Name of Firm9 9 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, PE Date 6/18/18 OF Aq...c.,•• 0 1 liQ ) 0*: 49TH /\ ;* /� 6. DSD SIGNATURE -141-""L-e-- -- System ' , i2/1•-&,.� yj .. Michael E.Anderson .S stem #1 Approved for bedrooms /� System #2 Approved for bedrooms ��islF9E(438h f �,���`^!� 1 0PROfESS\ ' Disapproved ,,\����\�.t~ Conditional approval for bedrooms, with the following stipulations: ,\C\QPL11.Y or xi/it ti . ON-S17-E oy o W4sTER AND �' WATER c.: PROGRAM 64 . ,(,,.r �O\ItrF Y� :::---77.._._' -- (�� Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_r .- ': C If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Arveson, Lot 8 Parcel ID: 015-273-13 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) N Date completed 9/18/72 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 157* ft. Cased to >40* ft. Casing height (above ground) 12 in. FROM WELL LOG AT INSPECTION Date of test 6/11/18 Static water level ft. 138.5 ft. Well production g.p.m. 4.6 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 1 .01 mg/L Arsenic ND ug/L Date of sample: 6/6/18 Collected by: Forge Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 9/14/05 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) NA Date of pumping 6/12/18 Pumper A Plus Home Services C. ABSORPTION FIELD DATA Date installed 9/14/05 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 .0 System type Deep Trench Length 28 & 21 ft. Width 2 5 ft. Gravel below pipe 4.5-5.5 ft. Total depth 109/9 ft. Eff. absorption area 483 ft2 Monitoring tube Y Depression over field N Date of adequacy test 6/11/18 Results (Pass/Fail) Pass For 3 bedrooms Fluid depth in absorption field before test 19.5/23 in. Water added 666 gal. New depth 24/30 in. Elapsed Time: 1440 min. Final fluid depth 18.5/23 in. Absorption rate >= 450 d 9 P. N Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: >100' >100' ad lots On adjacent Septic tank/lift station on lot j Absorption field on lot >100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' >25' >75' Sewer/septic service line 25 Holding tank Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: 10' >5' Building foundation Property line >5 Absorption field >100' Water main >10 Water service line >10' Surface water Wells on adjacent lots >1001 ABSORPTION FIELD ON LOT TO: 2'** >10 1 ' > ' Property line Building foundation Water main Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS *Per MOA Records. **MOA Waiver #WR050102 C ‘ G. ENGINEER'S CERTIFICATION 'r �p• F A :9sl�� I certify that I have determined through field inspections and /*: 49 TH /'"\ ••*iy review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. /-( Michael E. Anderson, PE �j Michael E.Anderson j Engineer's Printed Name r • g 6/18/18 r#,«,�•. 4381-E . �,/ Date i sTepi�, - 1 g -11,,,,..�.r i� F�PROFESS\O '4.. COSA brown sheet 10-10-12.doc