HomeMy WebLinkAboutFIRE LAKE #2 BLK 2 LT 4u xr � ��� neyv— ks tw •, � .0 ,�.t U �' � �� � ,� �..- �.� r '� � '�.3�», � a .�; � r ��x "ems. s -"�* z � � x � �k sa � u fi 1 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171065 PID Number: 051-351-20 Dwelling: ■❑ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑■ Upgrade Name: Simon & Scott Chambers ABSORPTION FIELD ❑■ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 13811 Savage Dr. Eagle River, AK 99577 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 10 0.8 GPD/SF 91 /9.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.1/3.8 Ft. Gravel depth beneath pipe 6.0 Ft. Subdivision Block Lot Fire Lake #2 2 4 Fill added above original grade 1.5/2.0 Ft. Gravel length 2 @ 79 Ft. Township Range Section Gravel width 3 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1896 Ft z 2 12 Ft. Well >100' >100' N/A N/A >25' TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 13000 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Martin Construction Drainfield D3034 CO/MT Inspector J. Milette BENCH MARK (Assumed elevation) 100 ft Inspection �5` 9/15/17 9/19/17 Location and description ddates: 2nd 3rd 4th Bottom of siding at point A COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp OF 4 Conditional Approval: �'' e • •4 4;4 d�10 DateJW . .. . J s 4-9THo� * MICHAEL E. ANDERSON CC: - 4381.^ AV 4o4s���o.� Approvedt?,�j�(',�� Date 1 18 a�-i •••���AW �$��i'ROFESSION�®®�0' mspecuon meport_a-1-1z.uoc \ � / /3000 -GAL SEPTIC TANK 4"Inss lafion Over Line SV2 linaer Driveway 2CO SVi O F 0 � 2 CO O m ;�. C3 LOT FD FIRE LAKE #2, BLOCK 2 LOT 4 PERMIT # OSP171065 PID # 051-351-20 \ A B I \ EXISTING CLASS C WELL \ LOT 3/ FCO 25.4 25.7 SV1 25.0 35.0 SV2 35.6 43.5 2CO 38.8 44.7 C01 101.0 78.6 CO2 105.0 78.3 CO3 109.1 79.3 FD 144.2 115.5 MT1 176.1 148.2 C04 179.8 151.9 MT2 184.2 153.5 C05 188.2 157.3 la 2 x 79' LONG x 3' WIDE, 6' EFFECTIVE DEPTH ABSORPTION A ALTERNATE SITE ' I ADVANTEX SYSTEM W/ TRENCH 32'x3'x6' LOT 5 EFFECTIVE DEPTH NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND OF `� PROPOSED SEPTIC SYSTEM r �' • • • •� lI CO - CLEANOUT *49 71i9yt,I� ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2C0 -DOUBLE CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEAN( SYSTEMS. FS - FLOW SPLITTER VALVE '. Michael E. Anderson : / MH - MANHOLE +''Fc •.• CE 4381 , �� i 0 50 100 MT - MONITORING TUBE �tisrF�FOp w FEET 1 ROFESSIONP ,� 1 "=50' SV -SEPTIC VENT TH - TEST HOLE FIRE LAKE #2 B2 L4 PERMIT # OSP171065 PID # 051-351-20 TRENCH #1 94.5 FINISH GRADE ,-93.0 ORIGINAL GRADE O U 09 79' 83.9 77.0 NO GROUNDWATER 6/15/16 N zk 2 ~ TRENCH #2 02 X95.1 FINISH GRADE 77.1 NO GROUNDWATER 6/04/13 93.1 ORIGINAL GRADE 0 79' 83.3 r)E)r'1C11 C AO 01111 T os>toci°""iyor MUNICIPALITY OF ANCHORAGE moment On-Site Water& Wastewater Programt; PO Box 196650 4700 Elmore Road . Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ..- http://www.muni.orglonsite `' * . I partuncnt ems' On-Site Wastewater Disposal System Permit Permit Number: OSP171065 Effective Date: 5/12/2017 Work Type: Septic Renewal Expiration Date: 5/12/2018 Tax Code Number: 05135120000 Site Legal Address: FIRE LAKE #2 BLK 2 LT 4 G:0454 Site Mailing Address: 13811 SAVAGE DR, Eagle River Owner: CHAMBERS SIMON SCOTT & Lot Size in Sq Ft: 49658 Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 10 This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: (it(tili h1 0 L/ Date: E 5 Issued By: -c/e c ( s - r C Date: 5 1 MUNICIPALITY OF ANCHORAGEcp67 g (T.)Community Development Department Ph I.: 34 3-7904 Development Services Division x34347 fi' On-Site Water& Wastewater Program �Q ON-SITE SEWER/WELL PERMIT APPLICATION 01 6 B L c,n c. Parcel I.D. 051-351-20 Property owner(s) Simon Scott & Lynde Chambers Day phone 727-6414 Mailing address 13811 Savage Drive Eagle River, AK 99577 Site address Same Legal description (Sub'd., Block & Lot) Fire Lake #2, Block 2, Lot 4 Legal description (Township, Range & Section) Lot Size 49,658 Sq. Ft. Number of Bedrooms Ten APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank 0 Upgrade 0 Duplex (D) ❑ Holding Tank ❑ Renewal ❑x Multiple Dwellings 0 Privy 0 (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: / A NNV Waiver Fees: Date of Payment: 42III1 Date of Payment: Receipt Number: itJ fA Receipt Number: Permit No. OS19In(0 t05 Waiver No. Permit App_2- c: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 26, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 4, Block 2, Fire Lake Subdivision No. 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The absorption system on the subject lot has failed and must be replaced. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the proposed 10-bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic systems. The existing concrete septic tanks will be decommissioned in accordance with Municipal Code. In addition, the existing absorption trench system will be decommissioned in accordance with Municipal Code. Also identified on the plans are the locations of the existing Class C well on Lot 3 to the north which serves this lot. No conflicts exist between the proposed septic system and the wells on adjacent lots. Drainage arrows are shown indicating the current drainage patterns. The ground surface in the area of the proposed trench is virtually flat. The drainage patterns will be maintained after construction. The test holes placed on the lot indicated Silty Gravel with Sand (GM) in the absorption zone of the trench. The percolation rate was determined to be between 6 and 15 minutes per inch. No groundwater was encountered during the placement of the test holes and none has developed to date. We have designed the new trench with an application rate of .8 gallons per day per square foot. We are proposing to place a new 3,000 gallon septic tank along with 2-79' long trenches by 3' wide with a 6' effective depth. The total depth of the system will be 10' with the distribution line at 4' below the existing surface. A flow splitter valve will be placed to insure even flow to each trench. Insulation 4" thick will be placed over the sewer service line under the driveway. The ground surface on the lot in the area of the new trenches is flat. The trenches will Lot 4, Block 2, Fire Lake No. 2 April 26, 2017 Page Two be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 74(_„k4i Michael E. Anderson, P.E. Attachments • 11 ' 49th •° •T 14-42_4i .-7ea4,44 tet L MICHAEL E. ANDERSON j C n . .."::3;••••• No, CE-4381 ♦•,i:ROF SS ° 44• FIRE LAKE, SUBDIVISION NO. 2 LOT 4'; BLOCK 2 49,658 S.F. Abandon Existing I ® Absorption System in Accordance with w Existing Class C Municipal Code. Well '-1 LOT 3 Q , \ S89'56'00"E / 300.00' 1 c.. / / Ply-4" Insulation 3,000 Gallon Over Line Under Septic Tank Decommission Existing in cn Driveway Septic Tanks in Accordance with Municipal Code. `t 2C0 I c0 1en 2-79' Long x 3' Wide x 6' Effective Depth wAbsoprption Trenches. 1- oTH 1j0 ® M iBedroom Singleo12' FSVeLOT 4 b/,/, amily Home La 0 ALTERNATE SITE: 1; Mico Advantex Treatment System Co TH2® 1 with 32' Long x 3' Wide x 6' _ I 1 D Effective Depth Absorption Alt. site 111/1 b Trench. Application Rate 4 GPD/SF. _���...\wt� NOTE: N89.56'00'W 300.00' .•*-`� OF � � No Surface Slopes >25% Within ����P;•.................. .. 50' of the New Absorption LOT 5 a �:•' •••, ♦ Trenches. No Surface Water I{t /. ,� *♦. Within 100' of the Proposed i r 49th�f Septic System. •1 itiir. c • ` LEGEND O ';MICHAEL E. ANDERSON :i..I if SITE PLAN MT - Monitor Tube ♦ No. CE-4381 ..4) FCC - Foundation Clean Out ♦C TH - Test Hole ♦1.40%..._)-tt-/r �, •: SCALE 1" = 50' Co - Clean Out • % PROFESSICtP��� 2C0 - Double Clean Out FSV - Flow Splitter Valve LOT 4, BLOCK 2, FIRE LAKE NO. 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Ten Bedroom Home Deep Trench System Perc, Rate: 8 Min./Inch Decommission Exisitng 750 Gallon Concrete Application Rate: .8 GPD/SF Septic Tanks Per Municipal Code Place 3,000 Gallon Steel Septic Tank 6' Drainfield Rock 10 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 1,875 SF Absorption Area 1,875 SF/12 SF/LF = 156.25 LF Trench Length THEREFORE: Remove and Dispose of the Existing Concrete Septic Tanks in Accordance with Municipal Code. Place New 3,000 Gallon Steel Septic Tank and 2 - 79' Long x 3'Wide x 6' Effective Depth Absorption Trenches. Place Flow Splitter Valve to Insure Even Flow to Each Trench. Flowline in Trenches to be 4' Below the Existing Ground Surface. Total Depth to Be 10'. Insure 150' Separation Distance from Well on Lot 3 to the North. Natural Backfill 3'6" Geotextile Fabric 6" 4" Perforated PVC (Holes Down) 6'0" Drainfield Rock 3' I I TYPICAL DEEP TRENCH SECTION '414 1441 ,..•-•..�, (NO SCALE) • P\E• ... Air c9‘./ If NOTE: Grade Area Over Trench to Drain Away. / Pk 1+11.1. Minimum 6' Separation From Bedrock. : : 49th Minimum 4' Separation From Groundwater. • 1+• .1.1. • Minimum 100' Separation From Wells in the Area. •f,,=, MICHAELE ANDERSON i Minimum 100' Separation From Class C Well on Lot 4. �� %°•. No. CE-43e1 4�� Minimum 100' Se aration From Surface Water or Streams. . ,� •' .z-.. . ` '• P 1e+, • wasar ,1••1' MUNICIPALITY OF ANCHORAGE ovi�'r inkii�� DEVELOPMENT SERVICES DEPARTMENT ?• 1:' "'••':`45.:1� 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 '4. . $ i : 49th / SOILS LOG - PERCOLATION TEST I 1rL-1. . •44,44-, 101%1MICHAEL E. ANDERSON';C,N LOT L4, BLOCK 2, FIRE LAKE SUBDIVISION No. 2 •ei : No. cE-4381'• All LEGAL DESCRIPTION: � �!•�,�, . �� PERFORMED FOR: LYNDE CHAMBERS ,`'p E�+'�d DATE: 6/7/2016 PROJECT No.: vi*�m PARCEL ID#: TECHNICIAN: W. ROBERTS – DEPTH TEST HOLE # 2 (feet) 1 Y -` ORGANICS SLOPE SITE PLAN 2 '4 a 3 . •• - • • 4 :O • ! SEE SITE PLAN 6 - 4 .. 7 GRAVEL W/SAND { ' .4 AND SILT 8 : .• - . d•' • • • GM 9 - • • . .• WAS GROUND WATER ENCOUNTERED? NO 10 4 '.• IF YES @ WHAT DEPTH') DEPTH OF WATER AFTER MONITORING: NONE SEE SITE 1'L AN 11—\ ' : DATE OF MONITORING; 6/15/ICS 12 a:. GROSS TIME NET TIME DEPTH TO(INCHES) NET DROP 13 • DATE READING (MINUTES) (MINUTES) WATER (INCHES) 14 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 '..• •• 1 2:10 0.75" 16 s 2 2:40 30 5.00" 4.25" 3 2:41 0.50" 17 4 3:11 30 4.75" 4.25" 18— 5 3:12 0.50" 19 6 3:42 30 4.75" 4.25" 20— PERCOLATION RATE: 7.1 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3.5 FT. and 4.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I,MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFOR[y1ED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: c{ Z-4, — (7 Municipality of Anchorage gIFrg.egkk Z Development Services Department ,,�Q�.' +5' �+ • �r Building Safety Division �, 46,..,,,,k. r�0 On-Site Water and Wastewater Program / 49 4700 Elmore Road s � P.O. Box 196650 Anchorage.AK 99507 0 td www.ci.anchoraile.ak.us (907)343 7904 �r ��•.LARSE.SPURKLAND, i It.T.,-5,-... 1 co :Ir Soils Log - Percolation Test 1i'= c'� b I3. :.'. fs ! f;c t,4;.v s Performed For: LYNDE & SCOTT CHAMBER Date Performed: 5/� kii-N.,-,.. 7. Legal Description. Township, Range. Section: Slope Site Plan Depth r (Feet) OG/OL 2- ft A1* 3 . 4- 5- 6- 7- 8- 1901 - 5- 6- GM III 7- ��..•��ir 8- •• �.OF• q �0 ..";,:c;-...� •� .1 ��OUND WATER �- w z:` 7 UNTE D7 N O 49 TH s L 10 `� ... ...e.: .. .Y 6vmAT DEPTH? --- 0 Water Atter DRY p . E 11- MICHAEL E. ANDERSON .4 ng? 12- I+ :f.� CE-4381 .:4-L.-%.: Date 6/4/13 13 l4i pROFESS10�1*04• I 14- s li\,i,00Dl6. Reading Date Gross Time Net Time Depth to Water Net Drop 15- 5/24/13 1:43PM 0 MIN. 9.438" _.- 16- 16- BOH @ 16' 5.750". - 2:13PM. 30 MIN. . 9.625" 7- 5.813" 2:43PM. 30 MIN. 9.250" 1s 5.500"\--)---........_. 3:13PM, 30 MIN. 19- 20- 1 LPERCOLATION RATE $_Q min,::es ux i PERC HOLE DIAMETER 6. TEST RUN BETWEEN 4 FT ANI)4.5 FT COMMENTS PRESOAKED. PERFORMED BY: ANSON MOXNESS. I CERTIFY THAT THIS TEST PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GU LINES IN EFFECT ON THIS DATE. DATE: On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161052 Tax Code Number: 05135120000 Work Type: Septic Upgrade Permit Effective Dates: April 18, 2016 to April 18, 2017 Design Engineer: ANDERSON ENGINEERING Subdivision: FIRE LAKE #2 Site Legal Address: FIRE LAKE #2 BILK 2 LT 4 G:0454 Owner/Address: CHAMBERS SIMON SCOTT & LYNDE 13811 SAVAGE DRIVE EAGLE RIVER AK 995777509 Site Mailing Address: 13811 SAVAGE DR, Eagle River Lot Size in Sq Ft: 49658 Total Bedrooms: 7 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Proposed TH2 shall be completed prior to construction. If the results require drainfield revisions, an approved change order shall be acquired prior to construction. Test hole results shall be submitted with the inspection report. Receive Issued MUNICIPALITY OF ANCHORAGE • V Community Development Department Development Services Division On -Site Water & Wastewater Program Phone: 907 Fax: 907 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-351-20 i N if Property owner(s) Simon Scott & Lynde Chambers Day phone 727-6414 Mailing address 13811 Savage Drive Eagle River, AK 99577 Site address Same Legal description (Sub'd., Block & Lot) Fire Lake #2, Block 2, Lot 4 Legal description (Township, Range & Section) Lot Size 49,658 Sq. Ft. Number of Bedrooms Seven APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank ❑X Upgrade (D) Holding Tank 1:1Renewal ElDuplex Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 5(6 Date of Payment: No I Ito Receipt Number: (1QJ/6 Permit No. (35PI 105a Permit App.-: Waiver Fees: Date of Payment: Receipt Number: Waiver No. 0 of March 19, 2016 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 4, Block 2, Fire Lake Subdivision No. 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The absorption system on the subject lot has failed and must be replaced. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the seven -bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic systems. The existing concrete septic tanks will be uncovered, inspected and verified suitable for continued use. The absorption trench system will be decommissioned in accordance with Municipal Code. Also identified on the plans are the locations of the existing Class C well on Lot 3 to the north which serves this lot. No conflicts exist between the proposed septic system and the wells on adjacent lots. Drainage arrows are shown indicating the current drainage patterns. The ground surface in the area of the proposed trench is virtually flat. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Silty Sand with Gravel (SM) in the absorption zone of the trench. The percolation rate was determined to be between 6 and 15 minutes per inch. No groundwater was encountered during the placement of the test hole and none has developed to date. We have designed the new trench with an application rate of .8 gallons per day per square foot. We are proposing to place a 1,000 gallon septic tank in line with the existing concrete tanks. In the event the concrete tanks are found unacceptable a new 2,500 gallon septic tank will be installed. In addition to the new septic tank 2-55' long trenches by 3' wide with a 6' effective depth will also be constructed. The total depth of the system will be 10' with the distribution line at 4' below the existing surface. A new test hole will be placed prior to construction to verify the soils are consistent in the area and the alternate site can be constructed Lot 4, Block 2, Fire Lake No. 2 March 19, 2016 Page Two where it is currently proposed. Insulation 4" thick will be placed over the sewer service line under the driveway. The ground surface on the lot in the area of the new trench is flat. The trench will be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, w7t,c /j, aj --, Michael E. Anderson, P.E. Attachments VACANT 1 5 � Y °V 7 7 AREA MAP SCALE 1' = 100' N= 3„00,90.00S V O N 3 O X m O W c o V ME c J = U O O 0 z - v`E m = O O C 0 0c L.: CO LO �2 Q z 3„00,90.00S V O N E CO O E_ ME c J 0 U \ L - v`E m O J L.: CO LO :Dm V / c' e Oy 2 7 %o5 V� Q O O m= \\v r J ami 0�3 O O w \ U M UI C U — ® rn� C � X W ,96'491 3„00,90.00S V 1N3W3Sd3 .11lll n ,OL u E c O E_ ME c J 0 U R my - v`E . S 0 wcV mLL c' e Oy 2 c m j O %o5 V� :x Eur m= \\v r 1S`: ami 0�3 HniaQ HOVAVS E X d y c 00-0 N n� O = U m X¢ O E o rn m oaaia X j . c N++L V1 U )OL N G� a. �a a 3w U o m— — Yzo U O J E a c m � E o o� O y y 3 c m wcoo F- - 0 = U'01 Z F00< O LO O O M O J V MRMM c O � N O Q M . S 0 w U 0 0- V� :x O 1S`: O O \ M � O J w O = 4 � O m LO 3 C - N O 004 00 m m 3 U v j o � - n o o` HniaQ HOVAVS E X d y c 00-0 N n� O = U m X¢ O E o rn m oaaia X j . c N++L V1 U )OL N G� a. �a a 3w U o m— — Yzo U O J E a c m � E o o� O y y 3 c m wcoo F- - 0 = U'01 Z F00< O LO O O M O J Q M . S :W w U V� :x 1S`: LOT 4, BLOCK 2, FIRE LAKE NO. 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Seven Bedroom Home Deep Trench System Perc. Rate: 8 Min./Inch Verify Exisitng 750 Gallon Concrete Septic Tanks Application Rate: .8 GPD/SF Place 1,000 Gallon Steel Septic Tank 6' Drainfield Rock 7 Bedrooms X 150 GPDL8 GPD/SF (Application Rate) = 1,312.50 SF Absorption Area 1,316 SF/12 SF/LF = 109.68 LF Trench Length THEREFORE: Verify the Integrity of the Existing Concrete Septic Tanks for Continued Use. Place New 1,000 Gallon Steel Septic Tank and 2 - 55' Long x 3' Wide x 6' Effective Depth Absorption Trenches. Place Flow Splitter Valve to Insure Even Flow to Each Trench. Flowline in Trenches to be 4' Below the Existing Ground Surface. Total Depth to Be 10'. Insure 150' Separation Distance from Well on Lot 3 to the North. Natural Backfill 3'6" Geotextile Fabric 6 :--PVCed (Holes tDown) 6'0"1 1_1-�- Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 10' Separation From Class C Well on Lot 4. Minimum 100' Separation From Surface Water or Streams. GRE/ R ANCHORAGE AREA BOR GH �Dg Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 k_�`-I-) t - z�_-)1 _ c J / [ INSPECTION REPORT ON -SITES SEWAGE DISPOSAL SYSTEM NAME IJ�I <�NQ��YS'7� MAILING ADDRESS __/0�(kCJ'S7YUC/ /��il /_ PHONE � wZ7Z0 Z eeo LOCATION LEGAL DESCRIPTION/ __ F^`�C•L+ �/KG SEPTIC TANK: -7S0 GAG Coatrem '"kf DISTANCE 01 NUMBER OF FROM WELL MANUFACTURER MATERIAL(COMPARTMENTS INSIDE LENGTH INSIDE WIDTH__ _ LIQUID DEPTH — LIQUID CAPACITY 100 GALLONS. TILE DRAIN FIELD: i TOTAL LENGTH DISTANCE FROM WELL 140FOUNDATION_ bs=---NEAREST LOT LINE ZO t ___OF LINES--_[47 NUMBER OF LINES Z' DISTANCE BETWEEN LINES ___1_7I ___TRENCH WIDTH V IN. TOTAL EFFECTIVE ABSORPTION AREA 1-58—SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE ZN WELL:: TYPE ✓K4,( -GD_ BUILDING FOUNDATION CESSPOOL A DD D r1VFn DISTANCES: CONSTRUCTION JTA&Jaa-d NEAREST LOT LINE OTHER SOURCES DISAPPROVED—. INSTALLED BY: L-�Act G_vtSjvuCj SEWER LINE DEPTH: PIPE MATERIAL: 64 /� --_ PNi ONalf6E N Lp �Y17U1ft LOT SLOPE: REMIAR�KS: IVUC,4 #Z- IS rA W diSjr+W,m box Form EQ -032 NEAREST SEWER LINE.___ IN. ABOVE TILE - __ IN. —__ __ DEPTH ___ _ __—DISTANCE FROM: SEPTIC I SEEPAGE TANK 140L, SYSTEM REMARKS DIAGRAM OF SYSTEM oa y� �ickcl< I � �tit��w�` ro A N cI a � 1011 ��`Y .Z4'�•. VEaat� F Zoc �. , iuw `TSO QL..Serk"2e irµwc y3. ' IAOV Stec�. ¢� —DATE A6�r APPROVED G.A.A.B.