HomeMy WebLinkAboutFERGUSON LT 2Ferguson Lot 2 #051- 261- 30 MUNICIPALITY OF ANCHORAGE C DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME W'E V S4 1/'CIeSOxv PHONE 1 w ❑ UPGRADE MAILING ADDRESS f3 ( o x 15-;kC, T i & /V Ad LEGAL DESCRIPTION 7' 21 F46 K Cr 0501V Sip LOCATION NO. OF BEDROOMS Uy DISTANCE TO: Well Absorption area Dwelling PERMIT NO. EZ w r Manufacturer MateLialr— '5 / No. of compartments n iC y Liq. ca acity in gallons IF HOMEMADE: Inside length Width Liquid depth G yDISTANCE Jaz TO: Well Dwelling PERMIT NO. 2 F Manufacturer Material Liquid capacity in gallons O w= DISTANCE TO: Well Foundation Nearest lot liner PERMIT NO. J LL Z F zw No. of lines Length of eafbi ine Totallen% ! li es "/, 7 Trench w'dt inches Distance between lines G H Top of rile to finish grafi t Material beneath tile / �nehes Total effective abs prion area W Length Width Depth PERMIT NO. QH as w Type of crib Crib diameter Crib depth Total effective absorption area y DISTANCE TO: Well Building foundation Nearest lot line J Class Depth Driller Distance to lot line PERMIT NO. W DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS 10 SOIL TEST RATING ` INSTALLER REMARKS r o� APPRO ED DATTEE�� LEGAL 72-013 (Rev. 3/78) C7 TYPE OF SOIL HBSORBTION SYSTEM IS: TRENCH MHXIMUM NUM8ER 0F BEDROOMS � 4 SOIL RHTlNG (SQ FT/RR)� 125 THE REQUIRED SIZE OF THE SOIL 1-IBS0RPTION SYSTEM JS� ��R ::11 1 11 , -0 : � ���������� Khm 1? US lot 1=1 %, 1�, T. . FV- �������� el" THE LENGTH DIMENSION IS THE LENGTH (IN FEET) 0F THE TRFNCH OH oRHINFIELD, THE DEPTH OF H TRENCH OR PIT IS THE DISTHNCE BETWEEN THE SURFHCE OF THE GROUND HND THE BOTT0M OF THF EXCHVHTION (IN FEET) THERE lS N0 SET 1-1l0111 FOR TRENCHES lHE GRHVEL DEPTH IS THE MINIMUM DEPTH OF GRHVB, 8ETNEEN THE OUTFHLL PIPE HND THE 8OTTOM OF THE EXCHVHTION (IN FEET). I[:;!! 11-o 1 IF E W`I - 1: W 7 1`00 P-1 K 551 T 21 V0= �. lv "To As �oil ��.KJ No S: PERMIT F1PP1. I]::::H1, 4T HHS THE RESPONSIBILITY TO INFORM THIS DEPHRTMENT DURlNG THE INSTALLHTION lNSPECTIONS OF RNY WELLS HDJHCENT TO lMI5 PROPERTY HND THE NUMBER OF THRT THE WELL WlLL SERVE ~~� �`1,0(if < :�:*� ������IF.,: � 9 -1: 1( �) r A Ti Y I r? K F? H 171 L j T IN IfT0 BHCKFILLING OF HNY SYSTEM WITHOUT FINHL INSPECTIUN HND HPPRO;OL BY THIS DEPHRTMENT HlLL BE SUBJECT TO PROSECUTION 07, 147 10 owl 1 1 P7 X W 707 Fy Q �S U: � I�::: V�:�: V.1 :11���� 0 Et E GEO'li _CHNI CAL Et ®EVELk- 'MENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Earl Ellis 694-2774 SOIL LOG 688-2280 Soils Et Foundations Land Development Performed for: Name: Tel. No. Mailing Address: Legal Description: Depth (feet) Soil Characteristics 0 1 2 9. 10 12 13 QF y�8� *.° 1'01 °. 15 , •°e aq •• 16 •. ••.••. I °•.0.•Earl P .... .�� i¢ El ° N4 1745-E .�'-Z-'I Ground Water Encountered: Yes No If yes, what depth �cc���;``SS1 �� .�/ Proposed Installation: Seepage Pit Drain Field Comments: Performed by: Date: �P, a, o -n dV�J GU akD 12- k �4- cn. J U � t,�, LG, O -N, hC, ��C "71 VAW MAR 23 10083 Southceotral Diorict rffic e xi pt. of Nwuroli..—..., > LA M x rn M I 0 x m F- c er> > e. > P n 0 > rn tv ?a P. o ;00 o 70 70 v w " A ;c io w z A m 0 0 0 0 0 0 0 0 0 0 0 0 co CIS G, 110 . . . . . . . . . . . . 0 0 0 0 0 tv rD tTl tD rA kD In P71 PO I" PO ITI x ml �v m x Pri w 0 0 0 0 0 0 O 0 O 0 0 0 0 0 0 0 0 0 1 4 4 H 4 4 4 4 MAR 23 10083 Southceotral Diorict rffic e xi pt. of Nwuroli..—..., > LA M x rn M I 0 x m F- c er> > e. > P n 0 > rn tv ?a P. o ;00 o 83 :qh Ln tv co 110 MAR 23 10083 Southceotral Diorict rffic e xi pt. of Nwuroli..—..., > LA M x rn M I 0 x m F- c er> > e. > P n 0 > rn tv ?a P. o ;00 MAR 23 10083 Southceotral Diorict rffic e xi pt. of Nwuroli..—..., > m M x rn M I 0 x m F- c er> > e. > P n ;00 > M I'] tom 4Z� it e. p P ;00 o 83 :qh Ln co Received by: CASA to be released Date: niess otherwise requested by the engineer. 5. STATEMENT OF INSPECTION BY ENGINEER r f As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. t Name of Firm Anderson -Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineers Printed Name Michael E. Anderson, P.E. Date 9/24/2016 6. DSQ SIGNATURE System #1 Approved for l bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the *r 49TH Ilk following stipulations: s If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of ®n -Site Systems Approve! Checklist Legal Description: Ferguson, Lot 2 Parcel ID: 0517261-30 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 611/79 Sanitary seal (Y/N) Y Total depth 77 ft. Cased to 77 ft. FROM WELL LOG Date of test 6/1/79 Static water level Well production WATER SAMPLE RESULTS 30 ft. 10 Well Log (Y/N) N Wires properly protected (Y/N) Y Casing height (above ground) >12 in. AT INSPECTION 9/20/16 34 ft. 10.5 g.p.m. Coliform 0 colonies/100 mL Nitrate •817 mg/L Arsenic ND ug/L Date of sample: 9/15/16 Collected by: 907 Water Well B. SEPTIC/HOLDING TANK BATA Tank Type/Material Septic/Steel. Date installed 6/22/1979 Tank size 1,250 gal. Number of Compartments 2 Cleanouts (Y/N) Foundation cleanout (YIN) Y Depression over tank (YIN) N High water alarm (YIN) Date of pumping 9/26/16 pumper - JRs Pumping Y N C. ABSORPTION FIELD DATA Date installed 6/22/79 Soil rating (g.p.d./ftz or ft2/bdrm) 125 SF/BDRM System type Deep Trench Length 75 ft. Width 3 ft. Gravel below pipe 4 ft. Total depth 7.6 ft. Eff. absorption area 600 ftz Monitoring tube Y Depression over field N Date of adequacy test 9/15/16 Results (Pass/Fail) Pass For 2 bedrooms r Fluid depth is abs3rption field before test 39 in. Water added 600 gal. New depth 48 in. Elapsed Time: 1,440 min. Final fluid depth 39 600**in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons _ in. "Pump offlevel at Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Manhole/Access (Y/N) in. High water alarm level at Meets alarm 8 circuit requirements? Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100, On adjacent lots >100' Public sewer main >75 Public sewer manhole/cleanout > 100 Sewer /septic service line > Holding tank >75 Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5+ Property line >51 , Water main > Q Water service line >10 Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: , Property line > 10 Building foundation > 10 Water Service line >10' Surface water >100! Curtain drain None Noted Wells on adjacent lots >100' Absorption fie Surface water d >5, >100' Water main >10' Driveway, parking/vehicle storage >10' in. F. COMMENTS **Septic System is at the end of its useful life. Absorption is within the last 1" of its effective depth. G. ENGINEER'S CERTIFICATION 1 certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 9/24/2016 COSA brown sheet 10-10-12.doc 0 I, MICHAEL E. ANDERSONe: n CE-4381 •���a �I •........ = Municipality of Anchorage ?P�� SL, • - Development Services Department Building Safety Division =. On -Site Water and Wastewater Program 4700 Bragaw Street 5 P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-261-30 COSA # P I l Expiration Date: -7- 1. 1. GENERAL INFORMATION Complete legal description FERGUSON LOT 2 Location (site address) 20123 LAUGHLIN STREET, CHUGIAK, AK 99567 Current Property owner(s) DAVID & JANICE CROSS Day phone Mailing address Lending agency Mailing address 20123 LAUGHLIN STREET, CHUGIAK, AK 99567 Day phone Real Estate Agent ERIC DINSMORE Day pho Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems. Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 04/08/2011 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long aOW ,; system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen ' �.� ....:. encroachments deficiencies or discrepancies exist. 5. DSD SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: • „&i e%rte ti`s : k,Jtw�►t� -�-�-- w,yTER AND ' c" F' ,GRAM Attachments: %;`�� • •.... •'.l�®,;� COSA Checklist X Arsenic Advisory lT, Septic System Advisory Well Flow Advisory Nitrate Advisory Maintenance Agreements Supplemental Engineer's Report Other By: ✓° : Original Certificate Date: (Rev. 11105) / Municipality of Anchorage *A9 Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: FERGUSON LOT 2 Parcel ID: 051-261-30 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID # Date completed 6/1/1979 Sanitary seal (YM) Y Total depth 77 ft. Cased to 77 ft. FROM WELL LOG Date of test 6/1/1979 Static water level 30 ft. Well production 10 g.p.m. WATER SAMPLE RESULTS: Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 24+ in. AT INSPECTION 4/6/2011 `i# 6.15 g.p.m. Coliform NEG colonies/100mL Nitrate 14,16 mg/L Arsenic: t4V mgA Date of sample: 72011 Collected by: ArcTerra B. SEPTIC/HOLDING TANK DATA Tank Type/Material fttic/Steel Date installed 6/22/1979 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 41541 Pumper_Rs C. ABSORPTION FIELD DATA Date installed 6/22/1979 Soil rating (g.p.d./ftz or fe/bdrm)125 System type Trench Length 75 ft. Width 3 ft. Gravel below pipe 4 ft. Total depth 7.55 ft. (Measured 4/6/11) Eff. absorption area 600 fe Monitoring tube Y Date of adequacy test 4/6/11 Depression over field N Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test *44.4 in. Water added 1000 gal. New depth 48 in. Elapsed Time: 1335 min. Final fluid depth 43.8 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date -- D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 1001+ Absorption field on lot 1001+ Public sewer main 751+ Sewer /septic service line 251+ Animal containment areas 50'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 1001+ Holding tank 1001+ Manuretanimal excrete storage areas 1001+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 51+ Property line 51+ Absorption field 51+ Water main 101+ Water service line 101+ Surface water 1001+ Wells on adjacent lots 1001+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 101+ Building foundation 10'+ Water main 101+ Water Service line 101+ Surface water 1001+ Driveway, parking/vehicle storage 101+ Curtain drain 501+ (None Known) Wells on adjacent lots 100'+ F. COMMENTS *Assumed 4' effective and measured from bottom of lateral System operating in top portion of effective depth and/or sump/MT is showing more standing fluid than what is actually occurring in field given field layout with slope or biomat buildup in MT Field stayed in the test range for 2000 gal pre-soak and 1000 gal test w/out backing into ST G. ENGINEER'S CERTIFICATION i certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KENNETH M. DUFFUS Date 4/Os/2011 COSA Fee $490.00 Date of Payment 4—/q-0 Receipt Number Oc--5 t I C (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department a:. a Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage. ak.us (907) 343-7904 Septic System Advisory Certificate of On -Site Systems Approval # 111110 During a recent adequacy test on the septic system for Block , Lot 2 of Ferguson subdivision, 44.4 inches of standing water was observed in the absorption field. This indicates that approximately 93% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval SGS Ref.# 1111291001 Client Name ArcTerra Engineering and Surveying Printed Date/Time 04/13/2011 17:23 Project Name/# Ferguson Lot 2 Collected Date/Time 04/07/2011 12:15 Client Sample ID Ferguson Lot 2 Received Date/Time 04/07/2011 15:00 Matrix Drinking Water Technical Director Stephen C. Ede PWSID 0 Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 04/08/11 04/11/11 NRB Waters Department Total Nitrate/Nitrite-N 4.75 0.100 mg/L SM20 450ONO3-F B (<10) 04/12/11 AYC Microbiology Laboratory E. Coli Negative 1 100mL SM20 9223B A 04/07/11 DLC Total Coliform Negative 1 100mL SM20 9223B A 04/07/11 DLC s AS-BUILT _ AV G 14. L 1 N S -T- I hereby certify that I have surveyed the following described.' property_ � $ �� s✓ c� Imo.! ,:'C.; �, � :s 5�..•��„� 20 T'fit , � 1 Anchorage Recording Precinct, Alaska, and that the improve- ( rnents situated thereon are within the property lines and do not overlap or-encroach on the property lying adjacent thereto, that, `" , t no improv ments on property lyin adjacent thereto encroach � AME ge Atn - t on the premises In question and that there are no roadways 5'm cn sax, �v y 0, transmission e transmission lines or other, visiblq. easements on said property M: except as indicated hereon. d "' Dated at Eagle River, Alaska ` N6.8EM.5 this - day of A CJ U S 7` 200L 1t08ERT C. JOHNSON ,"plc, SCALE: , Registered, land Surveyor No. -LS Lf_ Box 77-0456, Eagle River, Alaska 99577 Phone (9,07) 694L2543