Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutBOREALIS LT 3Borealis
Lot 3
#015-203-11
Municipality of Anchorage Page 1 of _ Z
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: Slx301 GoZ5`f PID Number: bls— Z 03 —11 1
Name: J I111A "Uter
Wastewater System: ❑ New 'Upgrade
Address:
'4q00 ILP CtRct,6 �n1c.41. Rk °IgSt6'
ABSORPTION FIELD
Phone: /
384
No. of B Brooms:
❑ Deep Trench ❑ Shallow Trench 'c Berc Mound XOthef
LEGAL DESCRIPTION
Soil Rating: a� M*4 TW
Total Depth from original rade:
G', 1) rMlhc.
GPD/Sq. Ft.
Lot: Block: Subdivision:
BoiCeA LIS
Depth to pipe bottom from original grade:
3.b -' Lt. nt Ft.
Gravel depth beneath pipe
. Z 1 3Ft.
Township:
Range: ..�
Section:
Fill added above original grade:
r
Gravel length: !&(..1
t'> " (t Ft.
Ft.
i
WELL: n❑ �Jew ❑ Upgrade
E XI ST)F9 C.
Gravel width: t o,
Ft.
Number of lines:
Distance2 eenlines:
Ft.
Classification (Private, A,B,C): Total Depth: Cas
Total absorption area:
Pipe material: ASTM 03 034
t: LAS " q•' Ft.
360 SQ. Ft.
F l0 I A&G216
Driller: a Drilled: Static Water Level:
Installer: ' 1
'r i -ME S*,w►c.e
Date install d:
— 3 �I
Ft.
Yield:
Pump Set at:
Casing Height Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION DISTANCES
fR�Septic ❑ Holding US.T.E.P.
TO
Septic
Absorption
Lift
Holding, :Public/Private
'SewerLines
Manufacturer:
Capacity in gallons:
1600
From
Tank
Field
Station
Tank
C.l;p 0- s
Well-
Zoos+
ZODI-f
Zoot•t•Surfac
Material:
Number of Compartments:
loot+
1001t
1001+
—"
LIFT STATION
Water
Lot1
Line
�-
1
�
�+
�'
Size in oaunns:
i 500
I Manufacturer:
Aac.4lov�t.+i Taau G2txJLo .SYS i F
Foundation
Z 1+
IQ I
(Z Ii
"Pump on" level at:3,j
"Pumo off" level at:
High water alarm at:�
Curtain
1J oa
�j0
4
Pump/� Make & Model
a,U OSY 0S
Electrical Inspections performed by:
O. A
Drain
.
//n_r_ I
Remarks: L� ANNECTION EeTK/e_15Vu
BENCH MARK
wRS NctT
Se�-rlc- TAN. Exv/pi T 4 r �.
Location and Description:
TSA - Tot aF NaaaoL-6 L.Ao as
TH s Als jaao+ta'tlJl= rr t_i=sS
�►ff .5TKT) 0Oj
)iaTE ITT Psw 'Ovs 1!j G SApJP 1'"I tER CItF
Assumed Elevation:
1 C9O.O
SCF I�- yr S4fUALk&!_s Foe 0
=ENGII��$EAL
A
SCJ.
��� ; •'• '•..v i
.•49 �• �Ir�
• • • • • • • •
AI.IASjCA UJATE►Z
Inspections performed by: g ujh,CrewATE Dates:1st
2nd
• �JAMES P. WILIIAMS
3� 33-9jjs
Department Health and Human Seryices approval
c • NO. 9608 s
11�. �9•••, c.E.
of
.••'��
Flo
Reviewed and approved by: Date:
72-013 (Rev. 9/91) MOA 25
09/18/98 FRI 14:48 FAX 907 343 8214 BUILDING SAFTT DIV
r� r.�i_!E3$ ." :36' h•1 FPCH ARCTIC LIGHTS ELECT 037 ZXG 5381 n '
iNSPECTION REPORT
r0UzNICIPA? rrY OF ANCHORAGE, SUIL01ivO iIAFETY VVISIC N
3500 EAST TUDOR ROAD
IN-SPEC-1-10ti: Voicet:a dfr4 tN PECTl;E: _GAx• f.`T� .8 ''� IMI= ' 343-821 �.
NAME -1 rr c Lights Chgric . .......... Perm'st # 21 660
ADDRESS-. M Alphd QIYCIR _Rl�nne L_ 44EZ�96
LOT -g-BLQG!� „TRACT _.SUBDIUISON i30Lt&ha ,
C01FA 'LENTS or DIRECTIONS'.
Tft iS a 9 9ptIC s+j g*M Wntrai panel instalIRtiOn
NOTE: When i! apmallor! camp16t9d, PI**** fax approval to : 329«3246. Thanks
rmuch!1
.TN', E1P.C�! Final - ----`�uIF T� !<?!�: Y _fir.
NO NONCOMPLIANCE 0"EFIVE
j C01 RF-CTi0NR ESSENTIALS AS EXPLAINED ?ELO�N
MILL REEXAIIAINE T EXT lMPI=C`!'! lti 1 0Q,1'T N`'�-C•F. ►1NTtL..ltilv$PECTEt?
COMMENTS' _ f
Past -it' Fps y�Note 7E71
ff IPhone V
ImF,PFCTOR: � _, _._ .. ... DACE:2-r<�
WHEN CORRECTIONS ARE MADE LEASE CALL FOR REii�lSf-5Fi°•+TIC, N
W NOT REW)VE THIS NOTICE
N
0
D Percent Passing by Weight
N
w N W 4�- Un Cr �4 Co C0 O
27 O O O O O O O O O O O
v a o 0 0 0 8 o 8 o a
•
0
11
�D
0
0
IITI m 0
3" O � T � 7
o
2" C7 C o n - m
1/2" P �- • ? ❑
Q
,.� o fA
3/4"
" r
1/2"
3/8"
7 r
Vo. 4
� 0
#8 00
No. 10
a W ow
# 16 n�
No. 20 ¢ t-1 It CC]
0
#30 p �• co
No. 40 C/) in r) n-
#s0 7
No. 60
CA
#80 d W P'
No.100 CA p �
coy
No.200 p
a �f R°
n
� C
0.02mm ¢ CCD
C3'
n
CD
rM
0
o
tJ
o
su
Z
0
N
O
Z
0
'--•
O
Z
0
Oo
O
Z
0
0�
O
Z
0
v.
O
Z
0
.P
O
Z
0
W
O
Z
0
N
Z
0
••-•
o°
00
o
00
�i
N
W
o
o
9
^+ y
o
O
W
N
W
W
U,
T
00
A
Z)
0
1.
ry
y
MEMO
a
Gs
�•
N
(40')
H
Eml.
O
O
O
O
N>0
v
O
O
O
s
p
O
O
I++I
6
n
:D
rfo
00
momma
mmufN
'�®®®
O
®M®mmmm
®moi
-
--
m-m
mm
m®®
SOMME
�D
0
0
IITI m 0
3" O � T � 7
o
2" C7 C o n - m
1/2" P �- • ? ❑
Q
,.� o fA
3/4"
" r
1/2"
3/8"
7 r
Vo. 4
� 0
#8 00
No. 10
a W ow
# 16 n�
No. 20 ¢ t-1 It CC]
0
#30 p �• co
No. 40 C/) in r) n-
#s0 7
No. 60
CA
#80 d W P'
No.100 CA p �
coy
No.200 p
a �f R°
n
� C
0.02mm ¢ CCD
C3'
n
CD
rM
0
o
tJ
o
su
Z
0
N
O
Z
0
'--•
O
Z
0
Oo
O
Z
0
0�
O
Z
0
v.
O
Z
0
.P
O
Z
0
W
O
Z
0
N
Z
0
••-•
o°
00
o
00
�i
N
W
o
o
9
^+ y
o
O
W
N
W
W
U,
T
00
A
Z)
0
1.
ry
y
CJ
O
a
Gs
�•
N
(40')
H
II
cI
O
O
O
O
N>0
v
O
O
O
s
p
O
O
I++I
6
n
:D
rfo
00
O
�d r �
a IJ 00
vi p
000
J �
'-r
00
00
PROPERTY OWNER AGREEMENT
FOR THE MAINTENANCE OF AN
ON-SITE WASTEWATER DISPOSAL
SYSTEM
This agreement, dated _199, is made between the Municipality of
Anchorage Department of ealth and Human Se_rvices (DHHS) and the property
owner(s) of:
Lo f 3 Corea j� S 56(hilu1s1arL,
This agreement is made for the purpose of maintaining an on-site wastewater disposal
system on the subject property.
The property owners agree to the following:
Submit to the Municipality of Anchorage, on an annual basis, an inspection and
operation statement from a registered professional engineer. This inspection and
operation statement shall verify that the engineer has inspected all effluent and air
pumps, timers, and alarms, and that any deficiencies have been repaired and that the
system is functioning as designed.
(Signature)
(Si e)
(Printed Name)
M1, "M��ffi
(Printed Name)
----------------------------- Notarize Here
, ---_-----------------------------------
State f �(C' On this �,r�s day offs ����,
P.
personally appeared be ore e,
who is personally known to me
whose identity I proved on the basis of
whose identity I proved on the bath/affirmation of
to be the signer of the above document, and
i.
My
a credible witness
he/she acknowledged that he/she signed it. Notary Public
commission expires���/
MmAcipality of Anchorage �
Department of Health and Human Servicesjhc
825 "l-" Street
Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650
Mayor
http:i/www.ci.anchorage.ak.us
September 29, 1998
Jeffrey Garness, P.E.
Alaska Water & Wastewater Consultants, Inc.
7320 East Chester Heiights Circle
Anchorage, AK 99504
Subject: Waiver Request for Borealis Subdivision, Lot 3
Waiver Request #WR980062
Parcel ID #015 203 11
Permit #SW980254
Dear Mr. Garness:
Your request for a waiver of the required 10 feet horizontal separation from the
on-site wastewater disposal system to property line has been approved. The approved
separation distance is 3.0 feet.
This waiver approval applies to the existing on-site wastewater disposal system to
property line separation only. Any future upgrade to the on-site wastewater disposal
system will require all separation distances be met or another approval from this
department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-4744.
Sincerely,
Donna C. Mears
Civil Engineer
On -Site Water Quality Program
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR#L1_>Q0j
Ujaa,j PID# 015-203-11 HA# Permit # SW980254
Date Received: September 21, 1998
Legal Description: Lot 3 Borealis. Subdivision
Engineer: Jeff Garness, P.E, Alaaka Water & Wastewater ConsultantR. Inc.
7320 East Chester Heights Circle, Anchorage, Alaska 99504
Applicant: Jim Hunt
Waiver Requested: Lot line wiiver of 3 feet from the absorRtion field to the
east property line
Criteria: 1. Geology: Points
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2. Special Conditions:
3. Other:
Waiver is Granted: Waiver is NOT Granted:
List Conditions or Reasons for above:
Date: By:
Name of Reviewer
Rec #: 04066/5437 Amount: $ 115.00 Date Paid: Sept 21, 1998
Department of Health and Human Services U1"lr'L5
825 1" Street
Rick Mystrom, P.O. Box 196650 Anchorage. Alaska 99519-6650
Mayor
http:Uwww.ci.anchorage.ak.us
March 23, 1998
Jeff Garness, P.E.
Alaska Water & Wastewater Services
7320 East Chester Heights Circle
Anchorage, Alaska 99504
Subject: Waiver Request for Lot 3 Borealis Subdivision
Waiver Request #WR980003, PID 4015-203-11, HA980008
Dear Mr. Garness:
Your request for a waiver of the required 10 foot separation
between an on-site wastewater disposal system and a lot line has
been approved. The waived distance is 5 feet from the absorption trench
to the west property line.
This approval applies to the existing on-site wastewater disposal
system lot line separation only. Any future upgrade to the on-site
wastewater disposal system will require all separations be met or
another approval from this department.
If there any further questions or concerns regarding this waiver,
please call our office at 343-4744.
Sincerely,
Daniel J. Roth
On-site Services
ljw #7
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR# 980003 PID# 015-203-11 HA# 980008 Permit #
Date Received: January 19, 1998
Legal Description: Borealis Subdivision, Lot 3
Engineer: Alaska Water acid Wastewater
Jeffery Garness, PE, MS
Applicant: Jim Hunt
Waiver Requested: 5 feet from the Absorption trench to the West property line.
Criteria: 1. Geology: Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2 Special Conditions:
3. Other:
Waiver is Granted: X Waiver is NOT Granted:
List Conditions or Reasons for above: S E'F Ew/,/wEEI'ri S A rA rg6y L F1TE/p
DF YuST1F�c�TIuN
Date: 3 — %/ ` %Tl By: //4TN
Name of Reviewer
Rec #: 03470/6435 Amount: $ 115.00 Date Paid: January 19, 1998
Alaska Nater & Wastewater Consultants, Inc.
7320 East Chester Heights Circle — Anchorage — Alaska 99504
Phone (907) 337-6179 — Fax (907) 338-3246
September 18, 1998
Municipality of Anchorage
Department of Health & Human Services
P.O. Box 196650
Anchorage, AK 99519-6650
REFERENCE: Lot 3; Borealis Subdivision
Property line waiver request
SEF 2 1 JW
nwNIL IPALI I Y Ut AN(�owNAUk
ENVIRONMENTAL UAVIUS DIVISION
Request you issue a three foot property line waiver from the absorption field to the east
property line on the referenced property. We do not anticipate any adverse effects to
neighboring properties with the issuance of this waiver.
If you require additioppl information, please contact us.
►lm
JAG/gk
C . _ -`ilk -L?C" L----� Cry (o - LA L t i n - �'k \ �>C�U
PERMIT NUMBER:
SW984254 AS -BUILT DRAWING
aa' cc�p A" wit ALPHAIRLE
PWSI[] — HAalUS
2 f f 708 ""_-__� _-_.._-r.•-�
WATER LINE
(ASSUMED
LOCATION)
AIR COMPRES
2.2 PS va
3-
P�
KZMT3
MT41'
I
TH41
�451NG A 1
t
t IWU5U c B
I Mil
FCO
OLD SEPTIC I I
/ J SYSTEM I I
E EE EE EE EE EE EE EE
u
10' UTILITY EASEMENT
BOTTOMLESS IN1'ERMi1TANT
DOSING SAND FILTER
PARCEL ID NUMBER:
015-203-11
V 1500 GALLON
LIFT STATION
---- - ------
NOTES:
1) A CAP WITII A 1 1/4" HOLE.: WA
PLACED ON THE BOTTOM OF EACH
MONITORING 'TUBE.
2) 'THE UNE CONNECTION BETWEEN
UFT STATION AND EXISTING TRENCH
WAS NOT INSPECTED BY M
ENGINEER.
ALASKA WATER AND WAS'T'EWATER CONSULTANTS, INC.
7320 E. CHESTER HEIGHTS CIRCLE. ANCHORAGE. AK 99504
PHONE: (907) 337-6179/FAX: (907) 338-3246
LEGAL DESCRIPTION:
BOREALIS SUBDIVISION, LOT 3,
TYPE OF WORK:
AS—BUILT OF SEPTIC SYSTEM UPGRADE
PREPARED FOR: PHONE NUMBER:
JIM HUNT 384-3528/345-7217
DATE: DRAWN BY: SCALE: PAGE:
9/18/98 J.L.M./A. C. G. 1 = 40' 2 OF 2
. IxAfoJM CA=
- 96.52
...4 9.:..,.. 1.
.Y�• .N. .r1.y .'.M
-.JAMES P. WILLIAM$-
NO. 9608
Qfe^'•. C.E. .•���
{04p"profl.l\00(1\o
J
A
R
C
ST1
---
24.75'
15,50'
Sf2
-
16.00'
12.30'
MI -I
-._.--
16.00'
1225'
MT 1
1 B.75'
1:1.75'
-
MT2
24.75°
24.7S'
----
MT3
2'7.00'
46.25'
---
MT4
20.75'
42.30'
— -
V 1500 GALLON
LIFT STATION
---- - ------
NOTES:
1) A CAP WITII A 1 1/4" HOLE.: WA
PLACED ON THE BOTTOM OF EACH
MONITORING 'TUBE.
2) 'THE UNE CONNECTION BETWEEN
UFT STATION AND EXISTING TRENCH
WAS NOT INSPECTED BY M
ENGINEER.
ALASKA WATER AND WAS'T'EWATER CONSULTANTS, INC.
7320 E. CHESTER HEIGHTS CIRCLE. ANCHORAGE. AK 99504
PHONE: (907) 337-6179/FAX: (907) 338-3246
LEGAL DESCRIPTION:
BOREALIS SUBDIVISION, LOT 3,
TYPE OF WORK:
AS—BUILT OF SEPTIC SYSTEM UPGRADE
PREPARED FOR: PHONE NUMBER:
JIM HUNT 384-3528/345-7217
DATE: DRAWN BY: SCALE: PAGE:
9/18/98 J.L.M./A. C. G. 1 = 40' 2 OF 2
. IxAfoJM CA=
- 96.52
...4 9.:..,.. 1.
.Y�• .N. .r1.y .'.M
-.JAMES P. WILLIAM$-
NO. 9608
Qfe^'•. C.E. .•���
{04p"profl.l\00(1\o
J
Permit Number: SW980254
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On -Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Legal Description: BOREALIS LT 3
Design Engineer: Alaska Water & Wastewater Services
Owner Name: JIM HUNT
Owner Address: 4900 ALPHA CIR
ANCHORAGE , AK 99516-2252
( l __ (�o1?( )
Q i.t o,7 — 1
k )ZI_'il 6� " CA -'IV C\
Date Issued: Jul 22, 1998
Expiration Date: Jul 22, 1999
Parcel ID: 015-203-11
Site Address: 004900 ALPHA CIR
Lot Size: 16763 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
❑ Private Well ❑ Water Storage
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
THIS PERMIT ISSUED FOR THE CONSTRUCTION OF AN ALTERNATIVE WASTEWATER DISPOSAL SYSTEM.
THE ATTACHED PROPERTY OWNER AGREEMENT SHALL BECOME A PART OF THIS PERMIIT PACKAGE.
-aoom�e5s Intew'AaA
Received By: _k&n Ok.L �AgIWW4 Date:
Issued By: '�� ��:�d�i Date: 7- Z J • 78
Alaska Water & Wastewater
7320 East Chester Heights Circle — Anchorage — Alaska 99504
(907) 337-6179 — Fax (907) 338-3246
Consulting Engineers
June 15, 1998
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On -Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Sewer Upgrade for Lot 3, Borealis Subdivision
To whom it may concern:
The existing 4 bedroom house is served by an onsite septic system, and a community well. The
existing drainfield is still functional, however, the homeowner wants to upgrade the system.
Comments regarding the proposed upgrade are summarized as follows:
1. GENERAL: There are a number of site restrictions which limit the available spots to put the
new drainfield. These restrictions are summarized as follows:
• The location of the existing septic system/s
• The location of the community well
• The presence of impermeable soils at a depth of approximately 10 feet dictate that a shallow
type system be installed.
Given these restrictions, there is limited space on the lot to put the new drainfield; therefore, we
are proposing to install a bottomless, Intermittent Sand Filter (ISF). We also, request you issue a
3 foot lot line waiver from the east property line to the proposed sand filter.
2. SOILS: On May 7, 1998 a test hole was excavated and percolation test performed at the
area of the proposed septic upgrade. As can be seen from the attached soils log, there was an 18
inch organic layer. The soils below the organic layer was a SM layer with light gravel to a depth
of 6 feet, and then transition to a SM/ML layer to a depth of 16 feet (bottom of hole). At a depth
of 10 feet the soils became very dense with sidewalls smearing which we visually deemed as
impermeable. No ground water was encountered at the time of excavation.
3. TRENCH DESIGN: Bottomless Intermittent Sand Filter (ISF)
a. Percolation Rate: 40 minutes/inch
b. Allowable Application Rate for ISF: 2 gallons/day/ft2
c. Number of Bedrooms: 4
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 300 ft2
f. Effective Depth below pressure pipes: 2.5+ inches
g. Width: 10 feet
h. Length: 36 feet.
i. Effective absorption area = 360 ft2 (>225 ft2 OK)
j. Air Supply: Thomas Industries, Model 5070, "Anchorage Tank".
k. Air Supply Line: "Wasteflow" emitterline, 1/2 inch I.D, "Anchorage Tank".
1. Sand Material: Central Paving Products "Winter Road Sand"
m. Pea Gravel: 100% passing 3/8" sieve, less than 20% passing the 1/4" sieve, and
less than 1% passing the #8 sieve.
We are proposing to excavate down to a depth of 3.5 feet to 6 feet (maximum), place a minimum
of 6 inches of sand, install the air supply line, and cover it with 1.5 feet of sand. On top of the
sand, we will place 6 inches of 3/8 inch pea gravel, with the pressure laterals midway in the layer.
We will use a conventional lift station (Anchorage Tank), equipped with a programmable timer so
that flow can be intermittently dosed to the ISF.
4. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
5. TOPOGRAPHY: The lot slopes gently from south to north, and from east to west at less
than 15%. Approximately 30 feet to the north of the test hole MT pipe there is a 4 foot cutbank
which drops down to the road. The slope from the bottom of the new ISF to the bottom of the
cutbank is less than 25%. The ISF will be excavated into the side of a moderate hill. The
excavation depth at the deepest point will be 6 feet or less. In short, there are no concerns.
6. MATERIALS AND CONSTRUCTION PRACTICES: The materials used, and the
construction practices will comply with DHHS' "Intermittent Sand Filter Design, Installation &
Maintenance Manual". The contractor should read this document prior to construction. Copies
are available at the Municipal Onsite Services office (5th floor, 9th & L St.).
7. CLOSING: Given the site restriction, I think the ISF is the most viable option for this lot,
short of install a Recirculating Upflow Filter, which would be more expensive. I am open to any
suggestions from your department, which would be an improvement to the proposed design. I am
unaware of any adverse impacts this installation would have on adjacent wells or septic systems.
If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for your
assistance.
I
I
I
- - OMEGA CIRCLE
I -
I
I
!
!
I
I
I II
i II
LOT 15, BOREALIS LOT 14, BOREALIS LOT 13, BOREALIS
LOT 12, BOREALIS
I
I
I
LOT 11, BOREALIS
I
I II
I
I LOT 6, BOREALIS LOT 7, BOREALIS LOT 9, BOREALIS LOT 10, BOREALIS
SEE ATTACHED ADECI 1
/
WAIVER PAPERWORK LOT 8, BOREALIS SERVED COMMUNITY SERVED COMMUNITY
FOR THIS LOT, WATER AND PRIVATE WATER AND PRIVATE
SERVED�COMMUNITX !
/
SEWER SEWER
++ 1 WATER AND PRIVATE
/
SEWER
1
I
_ALPHAI CIRCLE
4 1
!
�
t
PROPOSED SEPTIC SYSTEM
1
LOT 3, B�REALIS (SEE DESIGN, PAGE 2 OF 3) I
LOT 4, BOREALIS.
St
SEE ATTACHED ADEC
-\ i
I LOT 5, BOREALIS WAIVER APPROVAL
FOR THIS LOT, I I LOT 2, BOREALIS LOT 1, BOREALIS I
! SERVED COMMUNITY SERVED COMMUNITY SERVED COMMUNITY
WATER AND PRIVATE WATER AND PRIVATE
WATER AND PRIVATE - - SEWER SEWER
SEWER
!
EXISI NG SEPTIC SYSTEM -e-'
LOT 5, BLK 1,
�� LOT 4, BLK 1, LOT 3, BLK 1,
/LOT 2, BLK 1,
LOT 1, BLK 11
TALUS WEST
TALUSVEST TALUS WEST
r TALUS WEST
TALUS* WEST
I
I
lQ01 WELL RADIUS WELL WELL I
l�
--
1 I I
I1\
TAUS DRIVE
--- _ - -/-1V
\
LOT 5, BLK 2,
LOT 4, BLK 2, I
I LOT 3, BLK 2,
LOT 2, HLK 2,
LOT 1, BLK 2, 1v.
TALUS WEST
TALUS WEST
TALUS WEST
TALUS WEST
TALUS WEST
PREPARED BY:
ALASKA WATER & WASTEWATER
:I.=7 A �o
LEGAL DESCRIPTION:
BOREALIS SUBDIVISION; LOT 3,:•
Q.... ........
TYPE OF WORK:
SITE PLAN
.. ....... ..
QO •� f y .' Garn as: .•
PREPARED FOR: PHONE NUMBER:
JIM HUNT 384-3528/345-7217
Q0 •. C 7953
��e~ ••p'••,...••'
\
DATE:
DRAWN BY:
SCALE:
PAGE:
6/8/98
J.L.M.
1 = 100'
1 OF 3
�4a rofessl0t'a
�'oo'000�©
NOTE
1. E AIR COMPRESSOR SHALL BE LOCATED IN THE GARAGE,
` THE CONTRACTOR SHALL PROVIDE A 0-10 PSI PRESSURE
GAUGE AT A LOCATION WHICH IS READILY ACCESSIBLE FROM
ALPHA CIRCLE I WITHIN THE HOUSE, NOTEi A 30 PSI GAUGE WILL NOT WORK.
1 2, THE AIR COMPRESSOR SHALL BE A THOMAS INDUSTIES
- -- — ---- MODEL 5070, AS SUPPLIED BY ANCHORAGE TANK. THE AIR
LINE SHALL BE 1/2 INCH DIA, HDPE (1 PIECE), INSULATED
+ WITH 1/2 INCH FOAM PIPE WRAP CR3 VALUE). INSIDE A 2
OO CLASS +•A++ W
PW$ID 21 + INCH SCK40 PVC JACKET. THE LINE SHALL BE BURIED TO A
�- RADlUS f MINIMUM DEPTH OF 3 FEET,
1708 3, THE CONTROL PANEL FOR THE STEP TANK SHALL BE
INSTALLED IN THE GARAGE.
uTllGAZno trurM W 8W66
1.25 INCH HDPE LINE SLOPED BACK
WATER SERVICE UNE ---_TO
LIFT STATION FOR DRAINAGE OF
LINE. NO LOW SPOTS WHICH WILL
GENERAL LOCATION)
ALLOW WATER TO COLLECT, ALL
' CONNECTIONS SHALL BE STAINLESS
STEEL 1.25 INCH HDPE, CONNECTS BANDS. WITHNOH SEINLESCLAMPS TEFL
TO EXISTING 4 INCH LINE.
/ AIR COMPFESSOR
AIR UNE
/
TH#1 -
LX1511N(A Mir JMT
4 MON
j�j
I I PROPOSED 10' X 36'
EXISTING TRENCH
III I I INTERMITTENT BOTTOMLESS
CO SAND FILTER (ISF)
INSTALL FC (
III
I I /m ° ° WrIsMT
J
III -
I� 3' LOT LINE WAIVER REQUESTED
—
/---
j I PROPOSED 1500 GALLON
S.T.E.P. SYSTEM WITH
EXISTING SEPTIC TANK,
TO ���.� / I I DUAL OUTLETS
AS DESIGNED BY ANCHORAGE TANK
BE ABANDONED COMPLETELYI
I EQUIPPED WITH A INTERMITTENT
i I I DOSING TIMER. CONTROL TIMER TO
/_j
r — — — — — — — — — — I B1 LOCATED WITHIN THE GARAGE,
10' UTILITY EASEMENT 10' UTILITY EASEMENT
EXISTING DRAINFIELD
THE CONTRACTOR IS RESPONSIBLE
HAVING THE WEST PROPERTY LINE
GED BY A REGISTERED LAND SURVEYOR
R TO CONSTRUCTION,
ALASKA WATER & WASTEWATER
BOREALIS SUBDIVISION; LOT 3,
OF WORK:
DESIGN OF SEPTIC SYSTEM UPGRADE (BOTTOMLESS SAND FILTER)
PARED FOR: PHONE NUMBER:
JIM HUNT 384-3528/345-7217
6/8/98 J.L.M. 1 = 30' 2 OF 3
°F'A�y a
' Je r Go . •e s;'
Av c 7953 �AeiP
s
—AIR LIKE COQ. 5FACW AT
A WM. 2 M f. OWNGO
"WA5fEFI.0W" fYM FROIA 12
ICY A aff1 GR fANK.-
3/ 4" 12A, 501, 40 FVC I.A1W5
( N r5, 9tU75. AN17 Fl.U5HN6
VALW5 FSR OWNGO M510IV)-,
36'
11/ 4" MBIA. 50140 HM -4" 171A. MOMfORING 11.E AT eAGN
17lSGHARGL UNR FROM CMR. PE;RFORAiRl %fWN fOP
51<;P f" MV MANIPOL12 OF W AM7 0151'R MON FIFF
INVW. (MLL 1/ 4 INGN VIA HaW
PLAN VIEW
��
6" LAYER OF 3/ B" FFA GRNWI.
W* fit PVC LAfeR&5 RMW
M117WAY IN 1W 5fRAIN-
(6RAVrI, MI.OW FK - 2.5" +)
2 rMf MIN. OF FLSR
AIR UNC 18" %LOW
f7 OF 5AM7—
MT 3/ 4" PVC LAiM5 OW -4)
7 f4IN& GRAD
3' MIN. OF COVER
Mf
PROFILE VIEW
10' x 36' W f0ALE5515F,
NO WWR ON M3OWM, PM55LW
PIPING IX51G V BY MNGO AW
5met? pYM1CkiOM TANK.
(
ALASKA WA'T'ER & WASTEWATER � ��,��.of •A�
\L DESCRIPTION:
BOREALIS SUBDIVISION, LOT 3,
OF WORK:
BOTTOMLESS SAND FILTER (ISF) DETAIL
PARED FOR: PHONE NUMBER:
JIM HUNT 384-3528/345-7217
6/8/98
J.L.M. I N.T.S. 1 3 OF 3
r���or
4 H
••• G••• •...... •••
• J f A.as:
o —7953 `4
�Q�npr0f essioao\c>
PHONE (907) 337-6179 • FAX (907) 339-3246
SOIL LOG - PERCOLATION TEST
LEGAL DESCRIPTION: BOREALIS SUBDIVISION; LOT 3,
PERFORMED FOR: JIM HUNT
DATE PERFORMED: 5/7/98
DEPT" TEST HOLE #1
(feet) ORGANICS
1
SM WITH
LIGHT GRAVEL
SM/ML
9 W/ LITTLE TO
NO GRAVEL
10 VISUALLY RATED
ASIMPERMEABLE
1 1 VERY DENSE WITH
SIDEWALL SMEARING
SOIL CLASSIFICATIONS
DATE
READING
IIIIIIIII
Nt I I II`9t
(MINUTES)
WA I CK LCVCL
READING
IYC I IJR%A
(INCHES)
5/7/98
II�111!11
(2d
HOUR PRESO
ALPHA CIRCLE
PROPOSED SEPTIC
N/N�.
3, HAREALIT'IH
12:27
67
MEN
12:57
30 MIN.
11
L7
3/4"__
r�B •
I;
60 MIN.
3 5/8"
10�
4
DATE
READING
SITE POLO N
Nt I I II`9t
(MINUTES)
WA I CK LCVCL
READING
IYC I IJR%A
(INCHES)
5/7/98
BEGIN PRESOAK
(2d
HOUR PRESO
ALPHA CIRCLE
PROPOSED SEPTIC
5/8/98
3, HAREALIT'IH
12:27
67
��LJT
IST
II I I
II
12:57
30 MIN.
11
L7
3/4"__
/
1:57
60 MIN.
3 5/8"
1 5/8"
4
1:58
XISTING SEPTIC SYSTEM
DATE
READING
CLOCrc
TIME
Nt I I II`9t
(MINUTES)
WA I CK LCVCL
READING
IYC I IJR%A
(INCHES)
5/7/98
BEGIN PRESOAK
(2d
HOUR PRESO
)
5/8/98
1
12:27
67
2
12:57
30 MIN.
5 1/4"
3/4"__
3
1:57
60 MIN.
3 5/8"
1 5/8"
4
1:58
(ADDED H20)
6"
5
2:28
30 MIN.
5 1/4
3/4"
6
2:58
30 MIN.
3/4"-
19 PERCOLATION RATE 4U (MIN./INCH)
20 TEST RUN BETWEEN 6.0 FT. AND_
COMMENTS: SOILS VERY DENSE BELOW 10 FEET. RECOMKNDJ TILT
PERFOMED BY ALASKA WATER & WASTEWATER I,
THIS WAS PERFORM D IN ACCORDANCE WITH ALL
DATE. DATE: / z- '?
FLHG. HULt UTA. o kIIVLM-01
.5 FT.
ABOVE 6 FEET BELOW GRADE
CERTIFY THAT I
IDELINES IN EFFECT ON THIS
`18910
Municipality of Anchorage"
On -Site Water and Wastewater Program a JUN
(907)343-7904
Certificate of On -Site Systems
Parcel I.D. 015-203-11
1. GENERAL INFORMATION
Expiration Date: (& _2 ! — l
Complete legal description BOREALIS; LOT 3
Location (site address) 4900 ALPHA CIRCLE *ANCHORAGE, AK 99516
Current Property owner(s) CHRISTOPHER BROWN
Mailing address
Real Estate Agent
Day phone 230-2416
4900 ALPHA CIRCLE 'ANCHORAGE, AK 99516
2. TYPE OF DWELLING:
© Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
Individual Well ❑
Individual Water Storage ❑
Community Class A Well
Public Water System ❑
WaiverNariance request for: N/A
Received
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual
Holding Tank
❑
Community
❑
Public Sewer
❑
COSA to be released to the engineer, urtle-ss otherwise requested by the engineer.
COSA Fee $ JAZ 6. Q,')
Date of Payment 612-2114
Receipt Number 0_�00f C�
COSA# 05cl(a12—W
Date:
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMEnQNSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Garness Engineering Group, Ltd. (GEG) Phone (907) 337-6179
Address 3701 E. Tudor Road, Suite 101, Anchorage AK 99507-1259 (
Engineer's Printed Name Jeffrey A. Garness Date � I ZZ 116
In conducting this evaluation, GEG orovided an engineering evaluation of the well and/or seotic
system in accordance with the guidelines and regulations established by the Municipality of
Anchorage and industry oractices. The reported results describe the condition of the system/s on the
dates of the evaluation. Seoaration distances were measured to readily identifiable features.
Hidden defects or encroachments may exist that were not identified during the evaluation. The
ooerational life of all wells and septic systems deoend on a variety of variables including, but not
limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of
construction (materials and workmanshio), and the water usage of the family utilizing the systems.
These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future oerformance of the systems,; therefore, GEG makes no warranty (express or
imolied) regarding the future performance of the well orseotic system. GEG makes no
representation whether an alternative well orseotic system can be installed on the wooerty in the
event either of the current systems fail The content of this report is for the sole benefit of the
oerson/party who retained GEG. Reliance uoon the information provided in this recent by any other
oerson or early, including but not limited to subsequent orooerty purchasers, is not authorized. In
short, GEG disavows any legal duty to anyone other than the oerson/party who paid for this moort.
RE cc 6 9,4
6. DSyDrS�IGNATURE
T System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved 'J
ON-S� Y
Conditional approval for bedrooms, with the following stipulati9WTER I'
Original Certificate Date: lc�
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 9-1-12.doc
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: BOREALIS; LOT 3 Parcel ID: 015-203-11
A. WELL DATA
Well type Cuss "A` If A, B, or C provide PWSID# 21 1708 Well Log (Y/N)
Date completed Sanitaryseal (Y/N)_ Wires properly protected (Y/N)
Total depth ft. Cased to ft. Casing height (abo round) in.
FROM WELL LOG AT I CTION
Date of test
Static water level
Well production " g.p.m. g.p.m.
WATER SAMPLE RES
Coliform colonies/100 ml. Nitrate mg./L. Collected 6y: GEG. Ltd.
Ar.Tenic: ug./L. Date of sample:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEP/STEEL Date installed 9/1-9/98
Tank size 1500 gal Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (YIN) YES Depression over tank (Y/N) NO High water alarm (YIN) N/A
Date of_pumping 10/14/2015 Pumper A+ HOME SERVICES
C. ABSORPTION FIELD DATA,' BE Ow Exi rNc RADEI
9/1-9/98 2.0 ISF
Date installed 1080 Soil rating (g.p.d./ftlor 1/bdrm 260 System type TRENCH
36 .. 100.25
Length 53 ft. Width 3 ft. Gravel below pipe 8.0 ft.
*4.16 360YES NO
Total depth 1 4sft. Eff: absorption area 848 ft Monitoring tube YES Depression over field NO
Date of adequacy test 6/21/16 Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test **21 in. Water added 689 gal. New depth 28 in.
Elapsed Time: 92 min, Final fluid depth 0 in. Absorption rate >= 600+ g.p.d,
Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE If yes, give date —
**SUMP IN 1980 TRENCH ONLY EXTENDS 4.83' BELOW INVERT. MT WAS INITIALLY DRY.
INTRODUCED 847 GALLONS UNTIL 21" OF LIQUID IN MT AND THEN BEGAN TEST.
—ISF WAS SURCHARGED ON 5/6/16. REQUESTED THAT OWNER GET FLOW DIVERTER SWITCHED TO
OLD FIELD
—TESTED 1980 TRENCH ONLY
—NORTHWEST MT IN ISF IS THE ONLY ONE THAT GOES TO THE BOTTOM OF THE PEA GRAVEL
IN SHORT, NEW MT'S SHOULD BE INSTALLED FOR FUTURE TESTING.
*SEE ATTACHED MAINTENANCE LOG BY A+ HOME SERVICES
D. LIFTSTATION **PER 1998 INSPECTION REPORT
Date installed 9/1-3/98 Size in gallons 1500 Manhole/Access (Y/N) YES
"Pump on" level at * in. "Pump off" level at * in. High water alarm level at
Datum
*
E. SEPARATION DISTANCES
Cycles tested * Meets alarm & circuit requirements? **YES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/ldft station on lot On adjacent
Absorption field on
Public sewer main
line
Animal containment areas
17,1
Public sewer manholaicieanout
Holding tank
Manure/animal excrete storage areas
.SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+ PRIVATE/ 200' TO CLASS "A" WELL
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line *3'/**6.5' Building foundation 10'+ Water main 10'+
Water service line & 10'+ Surface water 100'+ Driveway, parkingivehide storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+ PRIVATE/ ***159' TO CLASS "A" WELL
F. COMMENTS
*WR980062 **W980003 ***SEE ATTACHED ADEC WAIVER
® A SS��•D �aS� �+Po.s �'1j/ g�X t-oLa�"rod
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Data (9 'b2%i (s
(Rev. 11/(15)
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY OF ANCHORAGE
AND ��cn (S+a1jf_1P^
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
22Day of June— e— of 20_1(p,by and between Pebxra E76jjek— ,
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as
located at (legal description).
P��rea la's 1
2. Definitions.
Alteration. Any change to the design or function of an AWWTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On -Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included
in the original design which would allow the AWWTS to continue to
perform as designed.
Permit. An On -Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AWWTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AWWTS is in use or is operational or until the
property is sold or title is transferred by the owner and a new COSA is issued to the
new owner or transferee of the property.
4. Alterations, Installation and Removal of Additional Eauioment. Prior to
performing any alterations to an AWWTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AWWTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AWWTS
service and maintenance provider approved by the municipality and the
manufacturer of the A W WTS for the entire term of the AWWTS. In addition, it
shall be the responsibility of the Owner during the term of this Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay
for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and (5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules
and orders for the AWWTS.
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to this
information.
D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On -Site Systems Approval.
H. Owner agrees that the AWWTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AWWTS.
6. Nonwaiver. The failure of either party at any time to enforce a provision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to enforce each and
every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
a. Owner: �p a- �s-Wo(E'f
b. Municipality: Director. Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
9. Severabilitv. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
OWNER:
By: - - (signature) Date: c©
c{ (print name)
STATE OF ALASKA )
) ss.
THIRD JUDICIAL DISTRICT )
The foregoing nstrument was ackno ledged before me this l day of �
Re�eCC�, � S§a���Y'
NOTARY PUBLIC F09
My Commission expires:
WNICIPALITY:
ALASKA
5.1 M Pu
By: (signature)
U. PHANNMANONG
State ofAb*A
My Commbaim Expires May 20.2020
Date:
name) Title:
Municipality of Anchorage
Development Services Department 4^
— i Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519650
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015- d03 - I I COSA# n(., o 35R
1. GENERAL INFORMATION
Expiration Date: q i 1 — I — 0-7—
Complete legal description BOREALIS S/D: LOT 3
Location (site address) 4900 ALPHA CIRCLE * ANCHORAGE. AK 99516
Current Property owner(s) JIM HUNT Day phone 345-7217
Mailing address 4900 ALPHA CIRCLE * ANCHORAGE. AK 99516
Lending agency Day phone
Mailing address
Real Estate Agent Day phone
Mailing address
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL=
Individual Weil
❑
Individual On-site
I
0
Individual Water Storage
❑
Individual Holding tank
[]
Community Class 'A" Well
E
Community On-site
❑
Public Water System
❑
Public Sewer
El
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Onsite Systems
Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 8 if Db
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readilyldentiflable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will It confer any legal right whatsoever.
5. DSD' IG
SIGNATURE
Approved for _14-- bedrooms.
Disapproved.
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
ON-SITE •��c
MMD
m=
WASTEWATER
• nnnnn u• • G
By: 04ee• / Original Certificate Date: / — 0
OR_ 11M
..�,.. Municipality of Anchorage
Development Services Department
�J Buiknng Safety DI ision
On -Site Water 6 Wastewater Program
4700 Brogaw Sheet
P.O. Box 196850
Anchorage, AK 99519.6650
www.muni.«yonsite
(907)343.7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVA
Legal Description: BOREAUS S/D: LOT 3
A. WELL DATA
Well type CLASS A.
Date completed _
Total depth
Date of test
Static water level
Well production
COMMUNITY WATER
If A, B, or C provide PWSID# 211706
Sanitary seal
Cased to ft.
FROM WELL LOG
WATER SAMPLE RESULTS:
Conform coloniez/100 mi.
Arsenic:
B. SEPTIC/HOLDING TANK DATA
ft.
g.p.m.
Nitrate mg./L.
L
CHECKLIST
Parcel ID:
wen
property protected
Casing height (above ground) in.
AT INSPECTION
I
ft.
g.p.m.
hof sample: Collected by:
I
Tank T
ype/Material S.T.E.P./STEEL Date installed 9/3/1998
Tank size 1500 gal, Number of Compartments E Cleanouts (Y/N) YES
Foundation deanout (YIN) YES Depression over tank (YM) NO High water alar (Y/N) i YES
Date of pumping 7/20/2006 Pumper A+ HOME SERVICES
i
C. ABSORPTION FIELD DATA
9/3/199e
Date installed 9/10/1974 Sail rating .p.d tj�lbdrrl 2.0/200 System type Gsc.-xuamae VO4H
Length 36/156 ft. Width 10/4 A. Gravel below pipe 10.25/1.5 ft.
z.a3+/
Total depth 7.5-11.5 ft. Eft. absorption area3gwAzi ft' Monitoring tube YES Depression over field NO
Date of adequacy test 7/6/2006 Results (Pass/Fail) PASS For 14 bedrooms
Fluid depth in absorption field before test 0 in. Water added 605 gal. New'depth 0in.
I
Elapsed Time: 0 min. Final fluid depth 0 In. Absorption rate >- 600+ g,p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN H yes, give dela
r�
D. LIFT STATION
Data installed 9/3/1998 Size in gallons 1500 Manhole/Access (Y/N) YES
"Pump on" level at TIMERin.
Datum BOTTOM OF TANK
E. SEPARATION DISTANCES
"Pump ofP level at nMERn. High water alarm level at 45 in.
Cycles tested 3 Meets alarm & circuit requirements? YES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankAiR station on lot
Absorption field on
Public sewer main
Sewer /septic service
areas
COMMUNITY WATER
On adjacent lots
On adjacent
sewer manhote/deanout
Holding tank
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation
5'+
Property line 5'+
Absorption field
5'+
Water main
10'+
Water service line 10'+
Surface water
100'+
Wells on adjacent lob 100'+/200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line
13'
Building foundation
10'+
Water main 10'+
Water service line
10'+
Surface water
100'+
Driveway, parkinglvehide storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+/200'+
F. COMMENTS
* WR980062 I.S.F. COMPRESSOR RUNNING* 4.0 PSI ON 7
G. ENGINEER'S CERTIFICATION JXIC-1. , ...
I certify that I have deterrnMed through field inspections and t*
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
............................
date. P *-A 11 y Ga asr
Engineer's Printed Name JEFFREY A. GARNESS •� j9 `
Date f5 4 Jb oP�or••.w0
COSA Fee 21 / Waiver Fee $ _
Data of Payment htp Date of Payment
Receipt Number Receipt Number.
(Rev. 11/05)
. ALPHA CI RCL F,'.
N 41
N69 5Y—+L_. W
t•Kty0•• !20.00.... - —-.....__i—
.r
f
Vy 3L.0
\ Srrvp - I O r • 27.7. O I \
O;///s .I N 1( NouOpRAME• r4 S.P. SP I ,
N h' fD I .. .
..-._.._.__-..-__... ..:29.5... ' '[w Nr 3.7 - ._..:. --- ._.i....-.. .
_ro Si
tn ,
ivr
7.
l I i
j
ldr/L. ESM/:
_ — 120.00
As Built PLAT, /\2:.. .•.�(,.17v .. No Corners Us This Gate Book No. pa" 1No .
vett
I
1 herabv certify thst 1 haw surveyed the following dowibed property, Lot -6 __ wC ,
802EA J_ 5 D. Anchorage recording Precinct. Alaska, and that i �lp�� OF
O N
IM improvements situated thereon are within the property lines and do not Overlap or * • e ' ,I
encroach on the property lying adjacent thereto• that no Improvements On property /
tying adjacent thereto encroach on the premises In question and that there *ran roadways. / 491N * /
Cogs e«'/••N'•e«N«••• ...
transmission lines OI Other vis NYments On mid property except M indicated hereon. Cogs ii
I/ 7s s h.n,t 11Yd.n., I/
Anchotaga, Alaska 26 oc r. 1988 II a , * , 9 � 0 reor"44 3044 f
• ! 2-oL
RECER r/flED 2 Aub. ZO04; "J— �QPttglggkl _�!�
AMM
A+ HOME SERVICES, INC.
7501 E. 140th Avenue
Anchorage, Alaska 99516
345-1890
CUSTOMER
• Jim Hunt
4900 Alpha Circle
Block Lot
INVOICE #
30506
DATE
DESCRIPTION
I
AMOUNT
Pump Septic &, clean lift if needed
I
Iq
Fuel 5urcharge 7-
430
9103 1230 eallons. 2 stanadives 3 hoes It It It ` s
Tank located 10' from behind house
TOTAL
r1 REMARKS
U t L
I
�2$G
SeptiJcLGallons g.
Leach Area HoldinTank
Standpipes Time
❑ PROBLEM AREA— CALL FOR MORE INFORMATION
❑ NEEDSTO BE DONE AGAIN IN 6 MONTHS
J" Good Shape ❑ sludge buildup on bottom
❑ Floater on top
❑ Jim cap missing or ❑ Cut standpipe to 1' above ground
❑ Needs Septictrine
needs replacing
MUNICIPALITY OF ANCHORAGE
• DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # O l " 26� "�� HAA # A q_000 5
1. GENERAL INFORMATION /
Complete legal description a02
Location (site address or directions) 49.00 A 1-241 G aC.ISE:-
Property ownerDay phone
Mailing address' Ct f-CLf—'_ 4W 644 -
Lending agency LA Day phone
Mailing address. N
Agent N AR Day phone f'j
Address tJ 'a,
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank -
Community on-site
Public'sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of thionspection.
Name of Firm Alaia
7320
Address Ain
Engineer's signature
6. DHHS SIGNATURE
_.Y Approved for bedrooms.
Disapproved.
Phone 33.7--6179
Date IZI
.: OF q
to
•4 •.
�• •�•.•• •• N•..
••
7 .
•� 1 re " ar�; •
f .• to C .7953
!,i PROFESSION:,'
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
aq
Date 3 — ��' 70
CAUTION
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent.
professional engineer registered in the State of Alaska. The DHHS does this as acourtesy to purchasers of homes
and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-M (Rev. 1/91) Beck MOA #21
JIRONMENTAL SERVICES DIVISIL
Municipality of Anchorage JAN 1 a 1998
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division R E C E I V E
825 L Street, Room 502 • Anchorage, Alaska 99501 * (907) 343-4744
Health Authority Approval Checklist
Legal Description: �� "� S Parcel I.D.:
A. WELL DATA
ell type Co�'Ir'l I ) , or C, attach ADEC letter. ADEC water system number
Log�prese/N) Date completed
Total depth
Sanitary seal (Y/N)
FROM
Date of test
Static water level
Well production
WATER SAMPLE R TS:
Coliform
Da a of sample:
Cased to
Nitrate
Casing height (above grour
Wires properly cte (Y/N)
Collected by:
INSPECTION
Other
g.p.m.
B. SEPTIC/HOLDING TANK DATA `" ISr--L Ti44 j4-
\
Date installed 91-74Tank size- Number of Compartments 2- Cleanouts (Y/NLy�
Foundation cleanout (Y/N) lja� — Depression (Y/N) N© 4 High water alarm (Y/N) N IA -
Date of Pumping 4131'.713 -98 Pumper
�--�' C. ABSORPTION FIELD DATA 1 qQ�o -M,g,,�
Date installed ( C1 160 Soil rating (g.p.d./ft2 or ft2/bdrm) 2-0 System type l Vj5j6t4
It -7 a SUMP =
Length=,.. 53 Width- 3 Gravel thickness below pipe g .Total depth ft. .-0
M
Effective absorption area a . 642) Monitoring Tube present (Y/N)Depression over field (Y/N)
Date of adequacy test I 1519 Results (Pass/Fail) P �S ForUl
G� bedrooms
31! Immediate) after teal. water added in.:
Fluid depth in absorption field before test (in.); y g ( )
2t iE
(.�Q Q + 4
Fluid depth � r � a (ins) Minutes later: � � Absorption rate = g.p.d .
-0(1.vfp = / • 8 ( 4. NON 'IG.►a v/ n1 y ^(
Peroxide treatment (past 12 months Y/N If es, give date
72-026 (Rev. 3/96)* S)jo'j ew 6'-)Unffl
N t't�, '• S vm P Ooh Avcr APJf a0- - v 6-v Tb B07—MM OF- 7VZCW
D. LIFT-CTATION
Date installed
Manhole/Access (Y/N)
High water alarm level at* *Datum
Cycles tested
E. SEPARATION DISTANCES
SEPA ELATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank
Absorption field on lot
Public sewer main
Sewer /septic service line
Size in gallons
at*
k
On adjacent lots
On adjacent lots
Ir1:11M
Lift station
"Pump off" level at*
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation J-11- Property line 1514- Absorption field ufJV-h1aW PJ
Water main/service line V) ( T Surface water/drainage [�} � r Wells on adjacent lots %00 i' �
•Look- PuBu�
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TQ:
l
Property line • -� Building foundation (0 /"1" Water main/service line 10
�"
Surface water I o0 + Driveway, parking/vehicle storage area 4-
No•.z'�/ r
Curtain drainWells on adjacent lots
Ca I.&S "14
F. ENGINEER'S CERTIFICATION
I certify that I
in conforman
Signature
-* PaQv&S-rO
spections and review of Municipal re
in effect on this date.
i
/5q' -t-a
rX
Engineers Name
/ �� '�%,•�
f! ��
Date `1$ �8 F�, .,� .••'����
a �opA�FESS10
HAA Fee $ 3rD '
Date of Payment J
Receipt Number S
72-026 (Rev. 3/96)*
Waiver Fee $ �� c i 7 bo)
Date of Payment �b
Mv
Receipt Number 76 (6 _3
are
7320 East Chester Heights Circle —Anchorage —Alaska 99504 'IRONMENTAL SERVICES DIVISit.
Phone (907) 337-6179 — Fax (907) 338-3246 JAN r
Consulting Engineers
January 18, 1998
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On -Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Subject: HAA for Private Septic System. Lot 3, Borealis S/D.
To whom it may concern:
The subject lot has a 4 bedroom house on it which is served by a private septic system and a class
"A" community well. The results of the field investigation and adequacy tests are summarized as
follows:
A. SEPTIC TANK: The existing septic tank was installed in September of 1974 (approx. 23.5
years old). According to the M.O.A records, it is 1250 gallons, has two compartments and is
made of steel. Most tanks of this type typically have a structural life of approximately 20 years.
No warrantee is made regarding the future life of the septic tank.
B. SEPTIC SYSTEM ADEQUACY TEST: There are 2 septic systems on the lot. The first
system was installed in September of 1974. It is a 4 foot wide trench, 156 feet long (total length
of 4 segments), and has an effective depth of 18 inches. According to the homeowner, there are
no visible standpipes for this system. The second drainfield was installed around 1980 (there is
no date on the M.O.A inspection report). It is 3 feet wide, 53 feet long, and has an effective
depth of 8 feet. The only pipe for this system is a 4 inch sump at the end of the trench. Based
upon our field measurements it appears that the sump only extends about 69.5 inches below the
drainpipe invert (effective depth is 96 inches per the M.O.A inspection report). An adequacy test
was performed on this trench.
On 1/13/98 the liquid level in the trench was 20.5 inches deep. Nine -hundred gallons was
introduced into the sump over a period of 167 minutes. This caused the liquid level in the sump
to rise 44.5 inches, to a total depth of 65 inches (approximately 4.5 inches below the .drainpipe
invert). This corresponds to 20.2 gallons/inch. Nineteen hours and 41 minutes later the level had
dropped 19 inches, indicating an absorption of 384 gallons. This corresponds to an absorption of
468 gallons/day, which is less than 600 gpd as required for a 4 bedroom house. We decided to
retest the system using a less conservative approach.
On 1/15/98 the liquid level in the sump was 39 inches deep (30.8 inches below the drainpipe
invert). Five -hundred and fifty-three (553) gallons of water was introduced over a period of 97
minutes. This rose the level 30 inches (.8 inches below the drainpipe invert), which corresponds
to 18.4 gallons per inch. Sixty minutes later the level had dropped 1.8 inches, indicating that
approximately 33 gallons had been absorbed. This corresponds to an absorption of 795 gallon per
day. Based upon this data the system was deemed to be adequate for a 4 bedroom house (600
gallons per day).
NOTE: The adequacy of a septic system is influenced by numerous factors, including, but not
limited to, seasonal surface water infiltration, groundwater variations, septic system
maintenance (frequency of septic tank pumping, usage of biological additives), condition of
drain pipe and pipe joints (which can be damaged by seismic activity and deteriorate with age),
type of substances deposited in septic system (cigarette butts, sanitary napkins, misc. objects),
and the amount of water being introduced on a continual basis. Consequently, the results of this
adequacy test are only valid for the specific day of the test. Furthermore, because of the limited
nature of this investigation, it is possible that there are hidden defects which may not have been
detected. No warrantee is made regarding the future performance of this septic system
C. SEPARATION DISTANCE FROM ABSORPTION SYSTEM TO THE PROPERTY
LINE: According to the 1980 (?) inspection report, the separation distance from the trench to
the property line is 16 feet. Attached is a site plan which shows the actual location of the sump
(per field swing ties, and a survey which did not show the sump). Based upon our field
measurement, it appear that the trench is only about 6.5 feet from the lot line. To be
conservative, I am going to assume that the trench is 5 feet from the lot line. The current
situation has existed for approximately 17 years, with no known adverse impact. Given these
facts, we are requesting that the subject separation distance be waived to 5 feet. The $115.00
waiver fee was submitted with this package.
D. SEPARATION DISTANCE FROM 1980 TRENCH TO THE CLASS A WELL
WHICH SERVES BOREALIS S/D, ALPHA CIRCLE: The trench installed in 1980 (?) is
only 159 feet from the subject well. The required separation distance at that time was 200 feet.
Was this reduced separation distance approved by the M.O.A at that time, or was the need for a
waiver overlooked? Please provide direction from your department.
If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for your
assistance. A
Sincerely,
.E., M.S.
ESTIMA
ALPHA CIRCLE
i SUMP FOR 1980
SYSTEM
3
APPROX. LOCATION OF TRENCH
INSTALLED IN 1981.
�OF A
LOT LINE WAIVER, LOT 3, BOREALIS S/DQ . • • .•. • ..:r:�V
PREPARED FOR, JIM HUNTQ• • ••• ..
f A. Garn • s.
o -7953 `
PREPARED BY, ALASKA WATER & WASTEWATER ti
, �OQa'°ro f easlor�4�
DATEi 1/18/98 DRAWNi GARNESS SCALEt 1 = 30 �ppo 00
,1 EXISTING 4 BEDROOM HOUSE
EXISTING 1250
ALLON SEPTIC
TANK
a
f-
oe
W
a
3�
0
oe
a
H
W
3
APPROX. LOCATION OF TRENCH
INSTALLED IN 1981.
�OF A
LOT LINE WAIVER, LOT 3, BOREALIS S/DQ . • • .•. • ..:r:�V
PREPARED FOR, JIM HUNTQ• • ••• ..
f A. Garn • s.
o -7953 `
PREPARED BY, ALASKA WATER & WASTEWATER ti
, �OQa'°ro f easlor�4�
DATEi 1/18/98 DRAWNi GARNESS SCALEt 1 = 30 �ppo 00
SENT BY;Environ.Conservstion 3-18-98 4;38PM Div Spill Prev Resp-► 9073383246;# 2
- WALTER J, NICKEL, OOVERNOR
. OF ENVIRONMENTAL CONSERVATION
ISION OF ENVIRONMENTAL HEALTH
NKING WATER and WASTEWATER PROGRAM!
CORDOVA STREET Telephone: (907) 269-7519
:HORAGE, AK 99501 Fax: (907) 269-7650
:/Iww•wv.state.sk.us/dee/home/htm
March 9, 1998
r. Jeffrey Garness
aska Water and Wastewater
71 Brookridge Drive
whorage, Alaska 99504
PWS 0 211708, Borealis SCD, Waiver of Separation Distance between Class "A" well and
the Septic System on Lot 3, Borealis S/D
ADEC # 9821 -WW -043-106
Mr. Garness;
received your payment and information related to your request for a waiver between the Class
A" well on Alpha ,Circle and .Lot 3 Borealis Subdivision. I have read with interest the reasons
or granting the waiver.
submittal was complete, showing that a separation distance waiver con be granted.
ie level of NitrEdes is at 0.675ppm, per your test. Annual testing by the water system manager
required to see if this value increases.
you have any questions, please contact me.
a UTU.7
RECEIVED
MAR 191f9$
Municipality of Anchorage
Dept. Health & Human services
Respectfully,
William R. Rieth, P.E.
Environmental Engineer
P-,lnn--�4
c
Ata s kal Water & Wastewater
7320 East Chester Heights Circle — Anchorage — Alaska 99504
Phone (907) 337-6179 — Fax (907) 338-3246
Consulting Engineers RECEIVED
February 10, 1998 MAR 19 1999
Municipality of Anchorage
Dept. Health & Human Services
State of Alaska
Department of Environmental Conservation
Division of Environmental Health
Drinking Water & Wastewater Program
555 Cordova Street
Anchorage, Alaska 99501
o.a 7-A v/9 a
Subject: PWS # 211708, Borealis S/D. Waiver of Separation Distance from Well to
Existing Septic System on Lot 3, Borealis S/D.
To whom it may concern:
The subject property has a single family residence on it that is served by a class "A" public well
(PWS#211708). The owner of the property, Jim Hunt, retained Alaska Water & Wastewater to
perform the engineering services to obtain a Municipality of Anchorage Health Authority
Approval (HAA) for the septic system. During our investigation of the system, and the M.O.A
records, it was determined that the drainfield (installed in 1980) was less than 200 feet from the
community well. Based upon the M.O.A records, and our field measurements, the septic system
is about 159 feet away from the well. We have reviewed the ADEC and M.O.A files and were
unable to find any documentation indicating that a waiver was ever granted for this encroachment.
The M.O.A onsite services office (Dan Roth, 343-4744) informed us that an ADEC waiver will
need to be obtained before their department will issue a HAA for the septic system.
The standard approach for evaluating the contamination potential for a hypothetical
encroachment is to use the ADEC point system. Due to the fact that we are not dealing with a
hypothetical case, but rather a real world scenario in which the encroachment has existed for
almost 18 years, it seems pointless to evaluate the contamination potential based upon a
hypothetical point system. In short, the fact that the groundwater quality has yet to be effected ,
after 18 years, is proof that there is virtually no contamination potential. The groundwater
source for Borealis subdivision is a confined aquifer that is protected by tight overlying soils.
Attached is a 100 scale site plan which shows the location of the well. It is impossible to put a
septic system on lots 4, 5, 6, or 7 of Borealis subdivision and maintain the required 200 foot
separation distance; consequently, waivers have been granted in the past for the septic system
upgrades on lots 4, and 6. In the case for Lot 6, Borealis, a waiver was previously issued for a
separation distance of 122 feet to the crib system. If your department determines that a point
evaluation is necessary, please contact us and we will do whatever is necessary to satisfy your
requirements. Based upon the aforementioned facts we are requesting that the separation distance
from the subject well, to the septic system on Lot 3, Borealis subdivision be waived to 155 feet.
If you have any questions, or require additional information, please contact me at 337-6179, or
244-9612. Thank you for your assistance and consideration in this matter.
Sincerely,
M.S.
c.c Jim Hunt
EXISTING CLASS 'A' WELL.
ZPWSIDIit
211708
LOT 6, BOREALIS
SEE ATTACHED ADEC
WAIVER PAPERWORK
LOT 7, BOREALIS
LOT BOREALIS
FOR THIS LOT.
ALPHA IRCLE
LOT 5, BOREALIS
LOT 4, BOREALIS.
SEE ATTACHED ADEC
WAIVER APPROVAL
FOR THIS LOT,
LOT 3, BOREALIS
XISTING TRENCH ON LOT 3, BOREALIS S/D
F
A
CLASS A WELL
TO SEPTIC WAIVER: LOT 3,
BK 1, BOREALIS S/D
* ;' 4
.....
.. ......
PREPARED FOR:
JIM HUNT•
••••
• ••••.•••
QQ�'�•e
cess•• D
SERVICES
s •• C 795
�' +
PREPARED BY:
ALASKA WATER
& WASTEWATER
.,
, ••' ���
0
DATE: 2/10/98
DRAWN:
GARNESS
SCALE: 1' = 100'°app°fassl°��
�OOpc�o
Alaska Water & Wastewater
atelr
7320 East Chester Heights Circle — Anchorage — Alaska 99504
Phone (907) 337-6179 — Fax (907) 338-3246
Consulting Engineers
March -5; 1995
State of Alaska
Department of Environmental Conservation
Division of Environmental Health
Drinking Water & Wastewater Program
555 Cordova Street
Anchorage, Alaska 99501
Attn: Bill Reith, P.E.
AwkA) coPr
Subject: PWS # 211708, Borealis S/D. Waiver of Separation Distance from Well to
Existing Septic System on Lot 3, Borealis S/D.
Dear Mr. Reith:
I received the correspondence you sent, dated 2/18/98. Per our conversations which followed I
am providing information on the Borealis subdivision well log, recent nitrate/bacteria water
sample results, and soils/groundwater data in the vicinity of the septic system. This information is
summarized as follows:
1. WELL LOG: Per our review of the ADEC file for Borealis S/D, there is no drilling
log for the well located in Alpha Circle. Therefore, we are using the log for the well located in
Omega Circle and assuming that the geological profile is similar (a reasonable. assumption). The
driller's log states that water was not encountered until a depth of 101 feet, but that the static
water level was measured at 75 feet. This is an indication that the aquifer is confined. According
to the log, there is a strata of silt/clay from 37-71 feet, and a strata of gravel/clay from 71-101
feet. These soil layers will hinder the migration of pollutants into the confined aquifer which lies
below them. Over twenty years of exposure to the effluent discharged by the surrounding septic
systems has yet to impact the groundwater source. A number of these septic systems are closer
than the one on Lot 3, Borealis S/D.
2. WATER QUALITY: Per your direction, we pulled samples (from the hose bibb at
Lot 3, Borealis S/D) and had them analyzed for nitrates and bacteria. A copy of the results are
attached. No bacteria was encountered, and the nitrate level was 0.675 mg/l, well below the
allowable level of 10 mg/l.
3. SOIL/GROUNDWATER CONDITIONS ON LOTS 3 & 4, BOREALIS S/D:
Based upon our review of the records for Lot 3, at the M.O.A onsite services office, it appears
that the 1980 septic system upgrade was based upon the soils log performed in August of 1974
(copy of log attached). This test hole was excavated to a depth of 14 feet. No groundwater was
encountered, and tight ML soils were noted at 13-14 feet. The soils was rated for 225 square feet
per bedroom. The existing system is installed to a total depth of 15 feet per the M.O.A inspection
report. The tight soils should (have for the last 20+ years) prevented the migration of untreated
effluent from reaching the subject aquifer. It is uncertain whether the system is in compliance in
regards to the separation distance to groundwater, or impermeable soils. Regardless, the
installation was approved by the M.O.A in 1980.
When the septic system on the adjacent property, Lot 4, Borealis S/D, was upgraded, a waiver
was obtained from ADEC for a reduce separation distance to the subject class "A" well. The test
hole for this upgrade was excavated to depth of 15 feet (copy of log attached). Groundwater was
encountered at a depth of 12.75 feet on 5/8/93. Whether this test hole is representative for Lot 3
is uncertain.
CLOSING: Based upon the aforementioned data, and the fact that over twenty years of septic
system encroachment on this well have yet to adversely effect the groundwater quality, it is
reasonable to assume that there is virtually no potential for subsurface contamination of the well
by the existing septic system on Lot 3. The only other path of contamination would be over the
ground surface (daylighting sewage flowing towards the well). Due to the fact that the house (on
Lot 3) has a daylight basement, it is highly unlikely that the septic system could overflow and
migrate towards the well, since such an event would first require that the basement be flooded
with approximately four (4) feet of wastewater, an event unlikely to go unnoticed.
Based upon the aforementioned facts, and the information provided in our letter to ADEC, dated
2/10/98, we are requesting that the separation distance from the subject well, to the septic system
on Lot 3, Borealis subdivision be waived to 155 feet. If you have any questions, or require
additional information, please contact me at 337-6179, or 244-9612. Thank you for your
assistance and consideration in this matter.
Sincerely,
P.E., M.S.
c.c. Jim Hunt
T4 HI
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: lM
LEGAL DESCRIPTION:
1 E
1
[j2
3
1� r
4
5
6-
7
7
8 ��-
9
b
10
11
12
BOT�G�S S/
S i• I -E- w-�9 ra ✓ -�I
sa...au,
SH
GM
els i j �-
13-
14-
15
3 14 15 oTToM
�kot-
16-
17-
18-
191 16171819
20
(ENGINEi'$�S L)
DATE PERFORME1D1_'. "'5 — Pj. •' 3
Township, Range, Section:
SLUPE
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT I L
DEPTH? L 0
93 e
Depth to Water After
Monitoring? I g2,7-5 Date b . / 7•
ME
■■■■■■■■■■
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
; 163_
� g 3
' S0
7/p
S a
3
r
J. O
• o
L L 'p 7
2i'jz
z
F2;tL
5
y 3
S
I PERCOLATION RATE_t
(minutes/inch) PERC HOLE DIAMETER 6_
TEST RUN BETWEEN •5 FT AND 5 FT
COMMENTS(—'•o_
PERFORMED BY:4� I 1 GL-n.r� ?��•V` CERTIFY THAT THIS TEST WAS PERFORMED IN
0 VIAACCORDANCE WITH A L STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
7'. 1 0 ,n. I r. _._. _.
>
H
•r: h
ar
�
a
-;
v
!
rY Q
i b
i
!
!
t
s
1
{
I
a
1
i
�
o
z
-;
v
!
rY Q
i b
i
!
!
I
i
i
a
1
.AL CT&E Environmental Services Inc.
CT&E RefJ
980802002
Client Name
AK Water & Wastewater Services
Project Name/#
N/A
Client Sample ID
Lot 3 Borealis S/D
Matrix
Drinking Water
Ordered By
PWSID
0
Parameter Results
Nitrate -N 0.675
Waters Department Analyses
Client PO#
Printed Date/Time 02/25/98 16:46
Collected Date/Time 02/23/98 13:45
Received Date/Time 02/23/98 15:25
Technical Director: Stephen C. Ede
Released By
PQL Units Method
0.100 mg/L EPA 300.0
Allowable Prep Analysis
Limits Date Date Init
10 max 02/24/98 RMV
Total Coliform 0 col/100ml. SM18 92226 02/23/98 TMW
TONY KNOWLES, GOVERNOR
DEPT. OF ENVIRONMENTAL CONSERVATION
DIVISION OF ENVIRONMENTAL HEALTH
DRINKING WATER and WASTEWATER PROGRAM
555 CORDOVA STREET Telephone: (907) 269-7519
ANCHORAGE, AK 99501 Fax: (907) 269-7650
http://www.state.ak.us/dec/home/htm
March 9, 1998
Mr. Jeffrey Garness
Alaska Water and Wastewater
8471 Brookridge Drive
Anchorage, Alaska 99504
Re: PWS # 211708, Borealis S/D, Waiver of Separation Distance between Class "A" well and
the Septic System on Lot 3, Borealis S/D
ADEC # 9821 -WW -043-106
Dear Mr. Garness:
I received your payment and information related to your request for a waiver between the Class
"A" well on Alpha Circle and Lot 3 Borealis Subdivision. I have read with interest the reasons
for granting the waiver.
The submittal was complete, showing that a separation distance waiver can be granted.
The level of Nitrates is at 0.675ppm, per your test. Annual testing by the water system manager
is required to see if this value increases.
If you have any questions, please contact me.
Respectfully,
William R. Rieth, P.E.
Environmental Engineer
WRR/cf
/ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMFNTAL PROTF..CI-ION
ENVIRONMENTAL ENGINEERING
DIVISION
825 L. Street - Anchorage, Alaska 99501
Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME/
/
/1 e, e Aye, i./ t(<'•_L9 _
:'Y �I -` /J `C
ElNFW
UPGRADE
MAILING ADDRESS
LEGAL DESCRIPTION
r
L ...+� SJ if li.�e7-fjlf
LOCATIONe'
'1 /I e4) /� %/�h A �'t � r f�
NO. OF BEDROOMS
-7
Well
Absorption area
Dwelling
PERMIT NO.
DISTANCE TO:
i
UY
—
n~ Q
Manufacturer
—
Material
No, of compartments
W t -
ti
Liq. capacity in gallons
IF HOMEMADE:
Inside length
Width
Liquid depth
Y
DISTANCE TO:
Well
Dwelling
PERMIT NO.
JAZ
2 Z F
Manufacturer
Material
Liquid capacity in gallons
D
Lu=
DISTANCE TO:
WellFoundation
S
Nearest lot line
PERMIT NO,
J LL Z
No. of lines
Length of each line
Total length of lines
Trench width
Distance between lines
z w
"5 ,3
36 inches
H
Top of tile to finish )r de
Material beneath tile
e� /
Tot 1 effectiv�absorption area
i
0
_! b inches
�s Is 114OC/T -116 0
Length
Width
Depth
PERMIT NO.
w
(7
i t—
Type of crib
Crib diameter
Crib depth
Total effective absorption area
w °
Uj
DISTANCE TO:
Well
Building foundation
Nearest lot line
J
Class
Depth
Driller
Distance to lot line
PERMIT NO.
J
LU
�
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption area(s)
OTHER
PIPE MATERIAL
SOIL TEST RATING
t? 0 0
INSTALLERjj
-c)
,
[i
[J - r
REMARKS
%/
� �ft4, A-1Jdf
f
a
t
e.
7oW
(y(iu y��� GTlf TG <' C Vn r,�c�- 1J `y,..c' ,i%�.,yl� D -I
�`.'•-
,f ,-i
ryl/
of
All 2 ct
"
l P
0
APPROVED DATE LEGAL
tea, is
72-013 (Rev. 3/78)
1%
N ���I #::: I F=o F-1 L_ I -r *-rl f-11 F=" ���VA Ilk F;-� 1=1 13 [=-
~ DEPHRT NT OF HEALTH AND BNYIRONM[ 'HL PROTECTION
u25 'L' STREET, ANCHORAGE, HN. 99501
264-4720
�
p
K:l t4--=-. I -r I-= t4 E: FZ'-* F="E=- FR.* rl 1-7-
PERMIT NO. ( 800411 )
�
°
APPLICANT LEE MHUR0 SRA BOX 1676H ANCHORAGE 344-7887
LOCATION 4900 ALPHA CIRCLE, ANCHORAGE
LEGAL L] BOREALIS LOT SIZE 16800 SQUARE FEE'
W
TYPE OF SOIL ABSORPTION SYSTEM IS: DRAINFIELD
�
MAXIMUM NUMBER OF BEDROOMS = `4 SOIL RATING (SQ FT/BR)= 200
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
����1-i= 'N ���1:3 -T "= �;2- 15 ��n %of E: L_ ���-r "= ::L'!ff-
�
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET)'
r "
/ E-: ����!--- " t.4 1101 -r " I '-=. 15' "-- 01D F=E:E:-r'
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET)
��0 U I F -e. C U- �C F=" -r 10 -r n r4 K �I :::' F="= :IL;2!ff- 0 0 n U. L_ 0 N n
�
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE
�U-4 C-1 ;R I r-4 *H. F--* E: C_ -r I k--1�� ���� �������1���� __
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
�
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM I5
100 FEET FOR H PRIVATE WELL OR 150 TO 200 FEET FROM H PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTANCE FROM H PRIVATE WELL TO H PRIVATE SEWER LINE IS 25 FEET AND
h
TO H COMMUNITY SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
^
AVAILABLE TO INSURE PROPER INSTALLATION.
F"E: Ferl I -r ���I F- . ��0 E: irl 13 EE F7-', =-:: -1 . ����&Z-1
�
I CERTIFY THAT
1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF HWCHORHGE
� .
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE I REMODELED TO INCLUDE MORE THAN 4 BEDROOMS
� .
SIGN� cu+� __,�==���_________________________
� NT
» VAN
ISSUED BY_-�� ��-�___��� _----- __DHTE__ _-_ Y4.(
� ^~~
�
�� b~~ ^,
) �_Acr�
GREA _R ANCHORAGE AREA BOR 3H
nrtfl®l,Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME BOU 27—AAS r rNe MAILING ADDRESS PQ• 1316 A'fr t'33 99Z 8 PHONE 333- '?-207-
LOCATION /11001.18 0-19'01E LEGAL DESCRIPTION Lor 3 /3O'e"413
SEPTIC TANK:
DISTANCEcQ� NUMBER OF
FROM WELL � MANUFACTURER5�..?72FA- MATERIALI�LA- f7fL6'7 COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY S-0 GALLONS.
TILE DRAIN FIELD:
n TOTAL LENGTH
DISTANCE FROM WELL C"Oii'VY!? FOUNDATION -:24) NEAREST LOT LINE %� , OF LINES
NUMBER OF LINES 3-4 DISTANCE BETWEEN LINES TRENCH WIDTH IN. TOTAL EFFECTIVE
ABSORPTION AREA 932 SQ. FT. LENGTH OF EACH LINE !" l a7 / '0?50 !
�! ! DEPTH OF FILTER !l
DEPTH: TOP OF TILE TO FINISH GRADE (Z MATERIAL BENEATH TILE—/L IN. ABOVE TILE °i� IN.
WELL:
TYPE ��CONSTRUCTION
BUILDING
FOUNDATION
CESSPOOL
APPROVED
NEAREST NEAREST
LOT LINE , SEWER LINE
OTHER SOURCES
DISAPPROVED
DISTANCES: 44 5.hOZ4111
INSTALLED BY:
SEWER LINE DEPTH: 7
PIPE MATERIAL:110-,K' "d
woo" nelao2Aad
LOT SLOPE:
REMARKS:
Form EQ -032
V0.3
SEPTIC
TANK_
DEPTH DISTANCE FROM:
SEEPAGE
SYSTEM_
DIAGRAM OF SYSTEM,
-107
DK'a�lN F'IELil i 1-- --I I ---i
1 145 1 1
1 1150
if787►! ti ptlTs
h�usR urulvl I 1Ilk
1 I
fv i 1 20 1 I I
r r
lan
J
DAT_9116171 APPROVED-�1'Ll�d-� `�A
G.A.A.B.
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO.
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
�ai:io uM • A''
SEWAGE DISPOSAL SYSTEM — APPLICATION AND PERMIT
NAME OF APPLICANT -'�-{ -' " U' �- ��F33 99�� PHONE 3.33-q2(b7
Q (/'y MAILING ADDRESS
INSTALLATION LOCATIONp/
LEGAL DESCRIPTION 407- • 3 f ,02� /S S /p
INSTALLATION OF: SEPTIC TANK I/ SEEPAGE PIT DRAIN FIELD OTHER
TYPE AND SIZE OF FACILITY TO BE SERVED "j r'
FINANCED THROUGH TO BE INSTALLED BY „la' »AI
SOIL TEST RESULTS //`�f7 NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED SLC m 7V'
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE 12S-0 TYPE
SEEPAGE AREA SIZE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK /
FOUNDATION TO SEEPAGE PIT U / DRAIN FIELD /0 /
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK SEEPAGE PIT
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
IRO / / /
. DRAIN FIELD ` 0
SEEPAGE PIT
DRAIN FIELD ALSO CONSIDER AREA WELLS.
lay/
WATER MAIN TO SEPTIC TANK SEEPAGE PIT /°
DRAIN FIELD 0/
SEPTIC TANK, ( SEEPAGE PIT DRAIN FIELD
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
G.A.A.B.
OR
LICENSED DESIGNER
TYPE
DIAGRAM OF SYSTEM
1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE �--/4/7 APPLICANT'S SIGNATURE[,���*�`�-
FORM NO. EQ -01 6
X
to
G
i
1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE �--/4/7 APPLICANT'S SIGNATURE[,���*�`�-
FORM NO. EQ -01 6
(1RLAI LR AMMORAGL API A i30ROUGH
DEPARTMENT OF ENVIR0NMFNTAL. QU/'l.(7Y Case
3330 "C" Street
ANCHORAGE, ALASKA 99503
Performed For _ Borealis_ Inc_._ —_ _ Dated Performed ---.8-27-74
Legal Description: Lot_3 BlockSubdivision Borealis Sub.
This Form Reports Soils l_og- --- ---- X____ ----_----___----_---_-____Percolation Test
- Soil Test Aust Be Loyged To 4' Below Proposed Seepage System -
Depth
Feet Soi l Characteristics
1 Organics (PT) Roots etc.
Sand to silty. Sand (SP --SM)
2 — Sandy fraction meet. to fine yellowish
3— brown w/random gravels. Low
4 ! moisture content.
5-
6-
7-
8-- Silty sand to silt with fine sand
9— (SM -ML) light gray random
10— angular gravel to cabble size mat.
1 1 — Increase in silt fraction with depth.
12—
13—
14--- Bottom foot tight silt (ML)
Bot. of Ex.
Was Ground Water Encountered? No
If Yes, At What Depth?
Reading
I Date
—Gross—Time
Net Time
Depth to 1]20
Net Drop
Percolation Rate _ _ _ M nuce
Proposed Insf;allation: Seepage Pit _.Drain Field
Depth of I n I et Depth to Qottoo Pi t: or Trend
- -
----------------------------
C 0 M M E N T S : With consideration for the upper sands and increase silt with depth we recommend
no less than 225 sq. ft/bedroom. We would also recommend consideration of a supplementary
drain field. -
Test Performed BY Howard Grey__ Date Certified BY:
4
5. LEGAL DESCRIPTION
DATE KECEIVED
e. OF.f s
INSPECTION APPOINTMENTS
TIME'
TIME
TIME
DATE
DATE
❑ One PC Four ❑ Other
DATE
INSPECTOR
❑ MULTIPLE FAMILY
INSPECTOR
INSPECT
MUNICIPALITY OF ANCHORAGE
* ATTACH WELL LOG. A well log is required for all wells drilled
MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH &
since June 1975. For wells drilled prior to that date, give well
DEPARTMENT OF HEALTH& ENVIRONMENTAL PROTEATIMMENTAL PROTECTION
•
825 L Street - Anchorage, Alaska 99501
0?YEAR
FEB 2 7 1981
ON-SITE SYSTEM WAS INSTALLED.
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720 RR17C EE vv EE PSREQUEST FOR APPROVAL OF INDIVIDUAL
WATER AND SEAICfLfTWER F
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTY OWNER
PHONE
5
MAILING ADDRESS
' �. �E ✓ P,^ oPLCAe*S
PROPERTY RESIDENT (If
different from above)
PHONE.
ACAOJT
2. BUYER
PHONE
iO
A eA* 7�
MAILING ADDRESS
! U11r
3. LENDING INSTITUTION
PHONE
aw
i - t2.
MAI LING A ESS
Itil.�l�'i`d�s 4N W4F T
4. REALTOR/AGENT
1046 te? o1jo
z tFA Re.ihAX 442 -274f
PHONE
MAILING ADDRESS
5. LEGAL DESCRIPTION
0 )06 p
e. OF.f s
STREET LOCATION
00 04
6. TYPE OF RESIDENCE
NUMBER OF,BEDROOMS
�I► SINGLE FAMILY
❑ One PC Four ❑ Other
❑ Two ❑ Five
❑ MULTIPLE FAMILY
❑ Three ❑ Six
7. WATER SUPPLY
❑ INDIVIDUAL*
* ATTACH WELL LOG. A well log is required for all wells drilled
14 COMMUNITY
since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
0?YEAR
DKINDIVIDUAL/ON-SITE**
ON-SITE SYSTEM WAS INSTALLED.
❑ PUBLIC UTILITY
�P A
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79) ���
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE ❑ OTHER
❑ TWO ❑ FOUR ❑ SIX
2. WATER SUPPLY
❑ INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑ INDIVIDUAL/ON -SITE
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATE INSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size:_ If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL C�
4. DISTANCES
WELL TO:
Septic/Holding TanT
sorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
LAY APPROVED FOR BEDROOMS
CC7 CONDITIONAL APPROVAL (letter must accompany certificate)
❑ DISAPPROVED
DATE
BY
72-010 ( Rev. 6/79)
MUNICIPALLTY OF ANCHORAGF
4. D`EPART'ME.WV ..,= l�,EALT+.t At4D . Y RO-NMENTAL .IROTEV,WN
825 L Street,.Anchor.age, Alaska 995.01
279-2511,, ext. 224, 225
Date Received: March 30,
1977'
lst Inspection: Time 1:,Sn pn2 2nd Inspection: Time
Date L/- /-17 p Date
inspector Inspector
REQUEST FOR APPROVALOFINDIVIDUALSEWER AND WATER' FACILITIES
-i
1. Lending Institution Request:
Mailing Address: Phone:
2. Property Owner: Donald/Edith Hall Phone:
344-281.8
Mailing Address; Star Route A Box 1576H 99507
3.' Legal Description: Lot.3 Borealis Subdivision
4. Single Family Residence: (x) Number of Bedrooms: 4'
Multiple Family Residence: ( ) Number of Bedrooms:
5. Well Data: Type Community Depth Well
Log Filed ( )
Construction Bacterial Analysis
6. Sewage Disposal System: On-site system (x) Public Utility E
Permit # Installed 1975 Installer'
Septic Tank Size Manufacturer
Absorption Area Soils Rate Material
7. Distances: Well, to Septic Tank to Absorption
P
-Area
to Sewer Lines Nearest Lot Line
Absorption' Area to Nearest Lot Line
MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
DEPARTMENT OF ENVIRONMENTAL QUALITY ENVIRONMENTAL PROTECTION
AR
'?®- f�Gt s�� a --zs�i MAR �')' U 1911
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES RECEIVED
1. Type of Inspection: CMRO VA FHA CONV XX
2. Property Owner: Donald $ Edith Hall
3
2
5
C:
M
Mailing Address: SRA Box 1576-H Anchorage, 99507 Day Phone 344-2818
Name of Buver: None at Present
Mailing Address: Day Phone
Name of Lending Institution: None at Present
Mailing Address: Phone
Name of Realtor or Agent: Mike Messick, Dynamic Realty, Inc.
Mailing Address: 501 W. Northern Lights Blvd. 99503 Phone 279-7611
Legal Description: Lot 3, Borealis Subd.
Location: 4900 Alpha Drive ,(Huffman Rd. to Talus Drive, Talus Drive to
Alpha Drive.
Type of Facility to be inspected: House No. Bdrms. 4
Water Supply
Type of Supply: Public Utility Community Individual
If Individual, number of dwellings presently served
If Individual, depth of well N/A
Sewage Disposal System
Type of System: Public Utility Individual (on-site) XX
If Individual, date of installation 1975
W14
YEQ-037 (1174)
I
Department Worksheet:
Department Worksheet:
TICK'
R&M CONSULTANTS, INC. 5029 CORDOVA ■ PDX 6081 R ANC11M AG1_ ALASKA 9950 E l�.}\9 -y QB."i �y�[090---
rE CI. C1rISr5 <�. 14,i N//=, d6�+ ( F
PL-ANNL— l7ls
';URVLVDRS'
May 2, 1977 R&M No. 751511
Mr. Donald
SRA Box 1576H
Anchorage, Alaska 99507
Re: Percolation Test on Existing Disposal System, Lot 3, Borealis
Subdivision, Anchorage, Alaska
Dear Mr. Hull:
On April 29, 1977, at your request, our office conducted a percolation
test on the septic system located on the above described lot.
The following table represents the level of the liquid in the drainfield.
The depth of liquid in the drainfield was initially 4.4 feet above the
bottom of the stand pipe. For the test, the liquid level was measured
from the bottom of the stand pipe.
Summary of Measurements
Level of Liquid Meter Reading
Time In Septic Tank(feet) in Gallons Remarks
0:00 4.40 3930.2(initial) As arrived
0:20 5.25 4055.3 Begin Test
0:55 4.45 4055.3(Final) 125.1 gallons
in 55 min(2.27 gpm)
The meter used during the test was a Rockwell 5/8" standard water meter.
The meter had previously been calibrated by R&M Consultants, Inc.
Since the house on the lot concerned was occupied, it can be assumed
that the leachfield in question was at its normal degree of saturation.
If it is assumed that the existing four bedroom residence will house
eight people, the average daily load on the disposal system can be
expected to be 600 gallons per day, or 0.42 gpm.
Since the existing disposal system accepted 125.1 gallons in 0:55 minutes
or 2.27 gpm, I would conclude that the leachfield is presently perform-
ing in a satisfactory manner for the attached residence.
ANCHORAGK FAIRBANKS JUNEAU VAI.111-Z WASIL-I_A
May 2, 1977
Mr. Donald Hull
Page -2-
If you should have any questions concerning this test or this letter,
please do not hesitate to call.
Very truly yours,
R & M CONSULTANTS, INC.
DOS 1E �5 mJ'�
Donald E. Bruggers
Geotechnical Engineer
DEB/gld
Municipality
Of
Anchorage
1 '113
k �?
POUCH 6-650
ANCHORAGE, ALASKA 99502
(907) 279-2511
GEORGE U SULL WAN,
MA YOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(825 "L" Street)
April 5, 1977
Mr. Donald Hall
Star_ Route A Box 1576H
Anchoraae, Alaska 99507
Subject: Lot 3 Borealis Subdivision
Before this department can approve vour reauest for
sewer and water approval, a percolation test must be
performed.
Your sewer system consist of a drainfield. This then
would involve vour contacting R & M Engineerina and
telling them you need a pPrcnlation test on your
drainfield. which serves an existina home.
If the test fails to meet the adequacv test, then an
upgrade will be needed.
If there are any further questions, please contact this
office at 279-2511, extension 224 or 225.
Sincerely,
►\ 44"uA P'X�
Robert C. Pratt, R.S.
Sanitarian
RCP/ljh
^i U
a2
' ��� �(AOAAGE AyEA
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received l';E;'"', "
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
S Gov.
1. Approval requested by: 3r = 1 i S Tr,f-.
Mailing Address: Phone:
2. Property Owner: "i ar l Phone:
Mailing Address:
3. Legal Description: Lot �, korealis Stjbdivisi«w
4. Location: ircic
5. Type of facility to be inspected No. of bedrooms
6. Well Data:
A. Type coolm'. s stelii
C. Construction pp rnved
7. Sewage Disposal System:
A. Installed `�� p'C— 1"7�
C. Septic Tank: 1. Size
B. Depth
D. Bacterial Analysis
B. Installer
2. Manufacturer
D. Seepage Pit: 1. Absorption Area 2. Material
E. Disposal Field: Total length of lines
8. Distances:
A. Well to: Septic tank , Absorption area Sewer Lines ,
Nearest lot line Other contamination
B. Foundation to septic tank Absorption area
C. Absorption area to nearest lot line
EQ -034 (1/74) Page 1 of two pages
GREATER ANCHORAGE AREA BOROUGH...,
1 Department of Environmental Quality
ry; 3330 "C" St., Anchorage, Alaska 99503 - 274-4561
M.
«11t1NY ..
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA FHA CONV_
2. Property Owner: L,rrPcI i S LaC _
Marlin Address: � 3.42�z�i3 or -
9 %�(� x e _f�s3 Day Phone 333--q12G7
3. Name of Buyer:
Mailing Address: Day Phone
4. Name of Lending Institution: l�e�a l Or T5<ccy�
Mailing Address: Phone
5. Name of Realtor or Agent:
Mailing Address:
Phone
6 . Legal Description: ,moo l
Location:
7. Type of Facility to be inspected: _kesjdeaC e- No. Bdrms . Z
8. Water Supply
Type of Supply: Public Utility A Individual
If Individual, number of dwellings presently served j
If Individual, depth of well fL$,
9. Sewage Disposal System
Type of System: Public Utility Individual (on-site)
If Individual, date of installation Sep . I el. 7-
etHca
EQ -037 (1/74)
Page 2 of two pages - Re A for Approval of Individual r & Water Facilities
Legal --Description Lot 3, Borealis Subdivision
Comments
Approved -Ilp�„c c ¢r� r�� Disapproved Date 12/9/74
Approval.,Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date