HomeMy WebLinkAboutMOUNTAIN PARK ESTATES BLK 8 LT 21 AA AASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION DIVISION OF WATER WASTEWATER DISCHARGE AUTHORIZATION PROGRAMS September 26, 2008 Lars Spurkland, P.E. Spurkland Engineering 203 West 15th Avenue, Suite 203 Anchorage, Alaska 99501 0 555 CORDOVA ANCHORAGE, AK 99501 Phoae:(907)269-7519 Fax: (907) 269-3487 http://www.state.ak.us/dee/ Re: Mountain Park Estates, Block 8, Lot 20 & 21 -Hillside Area, South Anchorage - Final Operational Approval for Domestic Wastewater Treatment and Soil Absorption System-ADEC Plan Tracking Number 7318 Dear Mr. Spurkiandi On September 25, 2008, the Department received the correspondence and record drawings for an onlot wastewater treatment system with a new 2,000 gallon septic tank, an Advantex Treatment System and a new bed type soil absorption system (20'x 37.5'=750ft2) for the 5 bedroom Duplex (750 gallons /day) at the above location. In addition an older failing existing wastewater system was decommissioned per the Uniform Plumbing Code, Appendix K. The new 2000 gallon septic tank and the Advantex system with two AX -20 pod, was installed to improve the effluent quality for disposed of effluent into the onsite soil absorption system which has a length of 37.5 feet. The disposal system is located on lot 20 with the duplex on lot 21. Lots 20 & 21 are owned by the same person and must remain dependent upon each other and not be separated due to any development that may occur. Percolation tests were run on the site material with 36.9 minutes per inch being determined in the area of the soil absorption field. The City of Anchorage would allow an application rate of 2 gallons/day /ft2 but a factor of safety has been applied which decreased the application rate to 1 gallon/day/ft2 resulting in a field of 750 ft2. The use of the Advanced Treatment System must maintain a continuous maintenance agreement. The list below has the current contact information identified, for the system to continue to allow operations, until it is replaced in the future: Advantex Representative is Tom Varney at (907) 272-3543 Owner is Donna Stichler at (907) 345-6771 Engineer is Lars Spurkland at (907) 279-3916 Pumper Service Mike Blakeslee (A+ Home Services (907) 345-1890) Plumbing Repairs Mike Blakeslee (A+ Home Services) Electrical Repairs Ed (Ed's Electric (907) 272-4591 Should these numbers or individuals change the owner must, provide updated infonnation to the Department. A copy of final operational approval with the maintenance agreement should be recorded with the property records. The Department has reviewed the final correspondence, certification of construction, and record drawings submitted for the onsite wastewater disposal and treatment system and per the Wastewater Regulations 18 AAC 72.240 final operational approval for the proposed system is hereby issued. Please use the referenced plan number in correspondence regarding this system. This approval does not imply the granting of additional authorizations nor obligate any state, federal or local regulatory body to grant required authorizations. Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18 AAC 15.195- 18 AAC 15,340 or an informal review by the Division Director in accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division Director, 555 Cordova Street, Anchorage, Alaska 99501, within 15 days of receiving the decision. A4judicatory hearings requests must be delivered to the Commissioner of the Department of Environmental Conservation, 555 Cordova Street, Anchorage, Alaska 99501, within 30 days of the decision. If a hearing is not requested within 30 days, the right to appeal is waived. Thank you for your cooperation, If you have any questions please do not hesitate to _. ..... contact me at 269-7519. Respectfully, William R. Rieth, P.E. Environmental Engineer Enclosure: As stated cc: William Smyth, WW, w/o enc. ----.� . �, have bash reviewed and are ❑ approved, conditionally approved (saeattached,candltions), �� .�. . t rrt s CATH 7canstruddOrl'bas not started wlthln two yisars of the wraval dite, thli carMate In Yald Arid newpfani end spociftgatform. most be submitted forrevf•w and spprovAl before cv*ruefan. 3. APPROVED CHANaE ORDERS Change (conaaetardor ma. orducrlpdve rsfawas) Approved by , Date APPROVAL YO OPERATE no'APPFIOVAL TO OPERATE" sscifon mutt be Completed and signed by the Cepartment tefore this system is made ava,7abIs for use. T+^e corstruc'!!an of the dam,ettfc ,vas!3,.1 a!sr disposal $' am was completed on (des). The sys!un to hereby g-stvsd �r!erfm approval to op4rat!ta'ar go daye fatia.�trg Its ccmp.'atton dale. ilY TrTLa CAT 9 As-buflt pars sutrni"ed durirg the °nlsrim appraval pe ad, or an frspec!!on * ere Csparlrrert, "as Xmffrrmsd ',�'srs!em Nes carstn,c!sd accardirg !d tie approved pars. 7` s e;ss!em ''s rereby grar!ed t;rd approval b opsr&%Ire Ma p GR= ~,TER ANCHORAGE AREA BOROU HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM ;,. ;: MA,,NO PHONE_ LEGAL ~/,- .~ ~ _ .MATERIAL_ ~¢¢£ ~-~'- ,~'~//~F(,fZ,I/L: COMPARTMENTS GALLONS. INSIDE ·LENGTH ~ NS DE WIDTH_ (xO DEPTHS, .- LOCATION SEPTIC TANK: D~STA.CE FROM WELL_ LI©UID CAPACITY /~'~:~:'~-~'~? SEEPAGE SYSTEM: NUMBER OF PITS LINING MATERIAL NEAREST LOl LINE_ SEEPAGE PIT: OUTSIDE DIAMETER ORW,DTH IZ, LENGTH /X-,OEPT"-6-, DISTANCE FROM WELL__ /~,~/'~? BUILDING FOUNDATION--.' -, TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) c ~'~-~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL_ NUMBER OF LINES_ ABSORPTION AREA FOUNDATION_ DISTANCE BETWEEN LINES_ SQ. FT. LENGTH OF EACH LINE NEAREST LOT LINE TRENCH WIDTH_ TOTAL LENGTH OF LINES iN. TOTAL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE_ DEPTH OF FILTER MATERIAL BENEATH TILB IN. ABOVE TILE__ WELL: LOT LINE NEAREST SEWER LINE_ ? DISTANCE FROM ,? WATER , BUILDING FOUNDATION._ I SAMPLE SEPT,C /7:: SEEPAGE /~:;_, cesspooL. TANK SYSTEM , NEAREST OTHER SOURCES _ DIAGRAM OF SYSTEM DISTANCES: &,::. ' ~: ,") .?~,, APPROVED_ HEALTH AUTHO:IT~ DATE GAAB-HD-2 GREATEL 327 Eagle St. ANCHORAGE AREA HEALTH DEPARTMENT Anchorage, Alaska 99501 ROUGH 279-2511 Case No. SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICANT (,,U,{A ~ RESIDENCE ADDRESS. ~(~/ dt/~,U/¢ LEGAL DESCRIPTION APPLICATION TO INSTALL: SEPTIC TANK TO SERVE THE FOLLOWING FACILITY FINANCED THROUGH PERCOLATION TEST RESULTS MAILING ADDRESS (-~'q{)( ~f/g2}/~ /{U[~: PHONE NO.~-~ LOCATION OF INSTALLATION ~/~}'- ~'/~ , SEEPAGE PIT '"'~, DRAIN FIELD TO BE INSTALLED BY ANTICIPATED DATE OF COMPLETION BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT ,OTHER THIS IS TO SERVE AS DISTANCES: bf:. 77L: 'To ~)z~, ~i,P+~J ~ , PERMIT TO INSTALL A AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED , SEPTIC TANK SIZE /,~-~--(-~ TYPE (~2~JS;~EEPAGE AREA DIAGRAM OF SYSTEMEZ 'l / Health Authority I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. DATE APPLICAN'[S SIGNATURE TELEPHONE: 272.4f 14 ALASKA GEOLOGICAL CONSULTANTS ENGINEERING GEOLOGY '~Y MINING ¢~ GEOPHYSICS I~ GROUNDWATER ¢r PETROLEUM 2227 SPENARD ROAD ANCHORAGE. ALASKA 99503 May 15, 1969 Mr. Bill Hand 4901 Chena Avenue Anchorage, Alaska Re: Percolation Test, Lot 2b, Block 8, Mt. Park Estates Subdivision Dear Mr. Hand: This letter is to certify that a percolation test has been conducted on the above-mentioned property. The test was performed in a 12" x 16" x 10" deep test pit in the bottom of the proposed absorption field. Location of the test pit, the log of the test pit and percolation data are shown on the attached sheet. This test was made in accordance with the Greater Anchorage Area Borough Health Department specifications as prescribed in Appendix B of the National Plumbing Code, 1962 Revision. Very truly yours, BGP:js ALASKA GEOLOGICAL CONSULTANTS Bruce Go Purcell Attach. [~IV ..................... DATr.' .............. CHKD, BY ........... DATE .............. SHEFZT NO ........... OF JOi'] NO II 4-' / DAli E-RECEIVED ~NSPECTION APPOINTMENTS TIME T~ME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSPECTO MUNICIPALITY OF ANCHORAGEpRoTECq~,/i:~iCiPALiTY OF ANCHORAG~ DEPARTMENT OF H~ALTH & ENVIRONMENTAl  825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL i:,~:oTEC'F~ON ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please allow ten {10) days for processing. PHONE 1. pROPERTY OWNER MAILING ADDRESS PHONE ~R~PERTY RESIDENT (tf different from above) MAI~ING ADDRESS 3, "LENDING INSTITUTION MAI L~NG ADDRESS _ ~ ~ PHONE MAIUNG ADDRESS ~ 5, LEGAL DESCRIPTION sT.. T L OATION 6. TYPE OF RESIDENCE SINGLE FAMILY MULTIPLE FAMILY ['~L[ ~>):- ~¥ 7, WATER SUPPLY ;~ INDIVIDUAL~' COMMUNITY [] PUBLIC UTILITY NUMBER OF~BEDROOMS [] One [~ Four Two [] Five Three [] Six [] Other__ * ATTACH WELL LOG. A well Icg is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available.) 8, SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS [] ONE [] THREE [] FIVE [] OTHER E~] TWO [] FOUR [] SIX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 2. WATER SUPPLY INDIVIDUAL COMMUNITY PUBLIC UTILITY Connection Verified 3, SEWAGE DISPOSAL SYSTEM []INDIVIDUAL/ON -SITE F-IPUBLIC UTI LITY Connection Verified [~]Septic Ta~gl~ or [~]Holding Tank Size:. t(~' If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4, DISTANCES WELL TO: Absorption Area to nearest Lot Line PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING MANUFACTURER MATERIAL ~____. ~__, Septic/Holding Tank Absorption Area ISewer Line INearest Lot Line 5. COMMENTS ~PPROV ED FO R _~_.__ B ED ROOMS I~ CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPRQVED ) / DATE I BY / ? 72-010 (Rev. 6/79) th~; r,~epti, c t. aNk ,ql~,]/O'( j!e4chJ, n;l ~i'ii;2 'i } )~ C "~ '~'' Uil:h a ]fOC:.?iil, t ' ii }/ 1 't;~;.,~ ,.~3 tills (>Fi hhc: 'rec(':lj~L an,'! vc{f.L.f~i~:<] :.)'-, n ~:'r.:,.j .... :' "'-,,4720,, ('tlt'(;Jl(~E ' ' , '. ' ',q, ('::;~L;('. C; ]_] t?li': .... ~: '/' ' j~t Z it. ,, ,,,{..I.(. , , ]>.{ CCI C(:IIt:klL'V -2,). ;;.[,':C,~;C'i: }:D.C. Tobben Spurkland P.E. 8155 Cranberry St. Anchorage, Alaska 99502 Phone (907) 243-5302 Lorraine.~lyj Century ~;'-~eeper 8050 Old Seward Highway Anchorage, Alaska 99502 Dec. 4, 1981 Legal Location Residence Owner Water System Sewer System SEWER ADEQUACY TEST Lot 20 and 21 , Block 8 Mountain Park Estate On Ridgeview 5 bedroom duplex Hand Onsite Well Two Systems See drawing below. System 1 Tank Concrete 1200 gal Absorption Log Crib 12x12x6 Installation Date System 2 Concrete 1650 gal Log Crib 12x12x6 Aug. 1969 Tobben Spurkland P,E, Lots 20 and 21 Block 8 Mountain Park Estate Date of Test Test Procedure Test Result Dec. 2,3, and 4 1981 System was inspected on Dec 2 and found as described above.The tanks were pumped and on Dec. 3 water was added to both tanks in increment of 250 gal. The following readings of the liquid depths were taken. Water Crib 1 Crib 2 0 34½ 54½ 250 38½ 57 500 43½ 67 750 45½ -- After 24 hours 39 52 During a 24 hour period system no. 1 had absorbed 443 gal and system no. 2 had absorbed more than 500 gal. System no 1 serves a two bedroom appartment and system 2 serves a three bedroom appartment. Both systems meet the Municipal requirements.