HomeMy WebLinkAboutNORTH WOODS BLK 3 LT 25Northwoods
Block 3
Lot 25
#051-731-57
UBMITTA
Municipality of Anchorage4
On -Site Water and Wastewater Program • (907) 343-7904 ;Fee")02f0
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number O S Ply / 222 PID Number: 0 5/7315 7
Dwelling: Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New p Upgrade
Name:
4'II4HC sr ,44'f OCJtC
ABSORPTION FIELD — FX/ST/i✓C
Address
22 P S3 AVC/2THWaC4 s Q/e.
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
❑ Other
Phone/' Q �i / ''7 ?
�j (J GI � (� / J f
Number of Bedrooms
3
Soil Rating
GPD/SF
Total depth from original grade
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
Subdivision / Block Lot
Ft
Ft.
/1/0 & T 11 N v 0 0 0 'j 3 c2.5
Fill added above original grade
Gravel length
Township Range Section
FL
Ft.
Gravel width
Beds: Number of Lines
Distance between lines
SEPARATION DISTANCES
Ft.
Ft.
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total absorption area
Fe
Number of trenches
Dist. between trenches
Ft.
Well
.)
NQ
TANK ',Septic • S.T.E.P. II Holding Other
AM
AM
/V,Q
Manuffa)cturerr�e
Surface Water
�1N/fa
t
if
q n ,f UlCapacity
40V c.- " 0Z4 o 6 7744/,c1 /000 Gal.
/W
W
fey
Qty
Material
Number of compartmentsnt
Lot Line
/d -<
is /..r-
1.F
/
.•-•0
NA
�c
S r C✓ii.
G
Foundation
5 14
lit
LIFT STATION EK/s rVs/G
�0
/0
Manufacturer
Capacity
Curtain Drain
_
-
_
--
Gal.
Remarks / �
uJ (.4/tll� i /s /s1LGE�4
Pump on level at
Pump off level at
High water alarm at
/�1//✓
(m (moi
in.
in.
in.
Pump make and model
Electrical Inspections performed by
Installer
Tank to
PIPE MATERIAL House to tank �vc- drantl&d /�✓Y+
q� '1 /' p v�-r
j) �✓T, a3A/,17h w/ iC/�
')
!I 3U>
Drainfield CO/MT
Inspector ,f� , t y. �
1 -`
BENCH MARK (Assumed elevation) /00 ft
Inspection a
dates: 13 (5/24%//S �J),-,13
' 2.�//S'
Location and description
"54 i..< cooz SILL
4�
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
Engineer's Stamp
niv,. •..m0
Er2 .t' •%?
$s . r ; it'
i'm
Approved Date Z -2-1
>.'sdg gW
a � ,s ; r.,tov. -v.
L44.miaII:v;-
Inspection Report_9-1-12.doc
AS -BUILT MEASUREMENTS
DCD1
ST1
ST2
DC❑2
A B
47
49
53.5
56
22
24
29
32
5X Slope
57. Slope
Existing
Lift Station
New 1000 Gallon
Septic Tank w/DCD's
Decommissioned Old
Septic Tank
PER UPC
Septic
0
5% Slope
Septic
0
Key Box
NORTHRIM
ENGINEERING *(�
PO Box 770724
Eagle River, Alaska 99577
907.694. 7028
NORTH WOODS S/D
BLOCK 3 LOT 25
WASTEWATER RECORD
REPLACE SEPTIC TANK
1" = 40'
RECORD
LAYOUT
Dote:
9/1/15 2 of 3
%
IN3H33V1d3d NNVl
33Id❑ad >INVI 3I1d3S
rn
8
I/S SI❑❑M
❑NIMVK I?J033?I
,S6 a uoi}nna
3
9-
0
\\
19'66 a uon ona
-5
&
gnouta13 uo fl tpuno3
\
&
186 B uoi}ona13
uoil nes 1-di3
•
On -Site Water and/or Wastewater System
Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151282
Tax Code Number: 05173157000
Work Type: SepticTank Upgrade
Permit Effective Dates: August 19, 2015 to August 18, 2016
Design Engineer: NORTH RIM ENGINEERING
Subdivision: NORTH WOODS
Site Legal Address. NORTH WOODS BLK 3 LT 25 G:1459
Owner/Address:
ST AMOUR MARK A & RUTH R
22853 NORTHWOODS DRIVE CHUGIAK AK 995675461
Site Mailing Address: 22853 NORTHWOODS DR, Chugiak
Lot Size in Sq Ft: 20046
Total Bedrooms: 3
This permit is for the construction of:
N Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 0 5/— 73/— 5 7
Property owner(s) mark ,c -t-, 4r�zo W -
Mailing address 02 Psi N,.,,{ -k -00c t.t
Site address
A Jr:
Day phone CeS"—‘73(
Legal description (Sub'd., Block & Lot) A./a,r or,d t 8..? tC Z
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
(IE all that apply)
Absorption Field ❑
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
teg
APPLICATION IS AN:
Initial
Upgrade
Renewal
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 21 G - Waiver Fees:
Date of Payment: $11y1/S
Receipt Number: ©511 b D
Permit No. OP 151Z$2
Permit App_9-1-12.doc
Date of Payment:
Receipt Number:
Waiver No.
Th'IM
ENGINEERING
Date: 8/11/15
To: MOA On -Site Services
MEMO
Steve Eng, PE, PH
(907) 694-7028 tel
SteveEngPE@gmail.com
Subject: North Woods S/D, Block 3 Lot 25
Septic Tank Failure
Number of Pages: 4
The subject septic tank has failed, the owner thinks may be in danger of collapse. Please expedite
a permit so the tank can be replaced. The tank baffles appear broken along with general tank
failure. Please review as soon as possible.
If there is need for additional information or clarification please give me a call.
Thanks -Steve
I\ERTIHRIM
ENGINEERING
North Woods S/D, Block 3 Lot 25
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: This is an existing 3 -bedroom, single family home. Most of
the neighboring lots are developed. The current septic tank has failed- the Bed/Lift
Station is still useable. These lots are large and are served by public water system. No
adverse impacts are expected from tank replacement. Easement is present on the lot. The
septic tank is almost collapsing- recommend expediting.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
• New 2- compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet.
• 5' minimum between the tank and bed. 10' to property lines.
• 4' of cover or insulation is required for tank; an equivalent of 1" insulation for
1' foot soil cover. Minimum of 2' soil with insulation.
• Tank & solid pipe must be set on well compacted, stable soil.
• 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation
wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two
adjacent opposing cleanouts between the tank and the absorption field, not more than
10' from the tank positioned to provide cleanout access towards the tank and towards
the absorption field.
• All cleanouts must extend to at least ground level.
• In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
• Insulation must be placed over any pipe installed under driveways or parking areas.
• Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
• Sewer Service Line is minimum 2% slope.
• Septic Tank to be pumped every two years or when required.
• Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal)
DESIGN NOTES:
1. Existing Bed/Lift Station Remains In Place.
2. Sewer Service Line minimum 2% slope.
3. Replace Septic Tank/Decommission Old Tank Per UPC.
4. Lots Served by Public Water System.
5. No Conflicts Within 200'.
5% Slope
5% Slope
Existing
Lift Station
New 1000 Gallon
Septic Tank w/DC❑'s
Decommission Old
Septic Tank
PER UPC
Septic
0
57. Slope
Septic
0
Key Box
00
3
4
NOR THRIM =4
ENGINEERING $tt
PO Box 770724
Eagle River, Alaska 99577
907.694.7028
NORTH WOODS S/D
BLOCK 3 LOT 25
WASTEWATER DESIGN
REPLACE SEPTIC TANK
= 40'
PLAN
LAYOUT
Dote:
ET:
8/11/15 2 of' 3
.5
cs
,§
0)
/
Foundation Cleanout
g Cleanouts Between Septic Tank & Trench
/
J
3
0C CU
/\
j
}
2
\
0
d
0 Cr
of
*K
on Compacted,
3' Cover,
F
SEPTIC TANK
so
2 �
c
2
r
3
i
.]d
TANK REPLACEMENT
72-013 (1/91) MOA 25
Municipality of Anchorage Page of
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: _✓W 01-7- (Co j PID Number. ' 11 ISS
Name it
tzv t�
Wastewater System: ❑New iJpgrade
q���
Address: 2 �• -�• --t-� t-lP�
2-7-63
ABSORPTION FIELD
Phone:643s nf^ ,., .
No. of rooms:
0 Deep Trench 0 Shallow Trenched 0 Mound 0 Other
LEGAL DESCRIPTION
Soil Rating:
4%)."4" GPD/Sq. Ft.
Total Depth from original grade/
'/'1!`
Lot: Block: Subdivision:
l'• -t 4:V=1 -V -ice'
Depth to pipe bottom from originalgrade:
Ft.
Gravel depth beneath pipe r
eAG Ft.
Township:
Range:
Section:
Fill added above original grade: r
l
1 'S Ft.
Gravel length: /
, Ft.
WELL: ❑ New ❑ Upgrade
Gravel4apth:10,1 ft.i t}} t
.Z Ft.
Number Hines:
I Distance bet ren lines:
Ft.
Classificationic���(Private, A,B,C):
iYt l- 1 ti. t4 l
Total Depth:
Ft.
Date Drilled:
Cased To:
Ft.
Static Water Level:
Ft.
Total absorption area:
I (-J 7i` SQ. Ft.
IInns�taalllller�:a /a /,..,.yam
C2CC, C.�- 44 l fZ' .
Pipe mateTial:- ,C �e
16.1*r1'1 -T.:/SQ.34 v
Date installed: /_ �1 �7
+/�l'-d !ice
.+1q/q-7---
Driller:
Yield:
Yield:
GPM
Pump Set at:
Ft.
Casing H ight Above Ground:
Ft.
��„ f 1 i� % ^ C TANK
SEPARATION DISTANCES
0 -optic 0 Holding 0 S.T.E.P.
To
From
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
Public/Private
Sewer Lines
Manufacturer:
Capacity in gallons:
��
1 Cll/�--2./
Well
1-}-
1 Alter
,,.(.
t+
Material:
Number of Compartments:
Surfac
Water
I6b1-t'
12:;-4--
1(00'
-1-
—
—
LIFT STATION
Lot
Line
�/ �
!O/
�/
l2'
t
i
�-
Size in gallons:
�)
Manufacturer:
IG{-i-cr -ere T'i1-l-1 lL'
Foundation
.02._.C..//�
�/
- `
t
cip,
'Pump on" level at:
Z8 a
'Pump off level at:
le"
High water alarm at:
Zit_n
�'-T�
Curtain
Drain
-" 1‘40
-Y•40(
----i\-1
�l� ti
Pump Make &Model
Elec rical Inspections performed by:
flp i --47-P'-G ,.‘-t,FG-re-1 C -----
'Pump
Remarks: jC1�j'r11.}(q 1L 1ts1i--rlf
BENCH MARK
I
om. \`--4-11-6 -11— -��
Location and Description:
—2 -X ISTt r�� c-
/)I4% 1-- .
t4te--
Assumed Elevation: I SDo
r Ft.
EN
tdir ar
rli�e• eaee•e•e.q 0i,
7 ea
f* i �y �. •.
8
/ oeoefiaa•es` see .ed.6•®
%
S 1 S ENGINEERING
17034 Eagle River LoopRoad, No. 204
Inspections performed by: Eagle River, Alaska 99577 Dates: 1st 17--
.
2nd'IP
e 906906.0 G9 . as
♦ F ; ROG R . SHAFER :-6 B
I® �"J(�ee No.8215 64®
®Lea s*. es•41• �eis�®®
Leaps*.-®_
Department of He and HumanServices approval
Reviewed and approved by: Date %- 24 -92
72-013 (1/91) MOA 25
Permit No 1‘1
Page
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: O 4u1oe 1-4 -
PID No• (%11-1--1-.
fir1 )oo-
GoZ t-tk)
(A—
IDZ�Co3NTZ
• A 1 "- 10
to/Iq��iZ
Gol
OUST: (oc,c,
S.T. Ft s i7
lnri:�Gi. VE'
r-l64r4 soa Q" -
L -r r Sr ftaJ
t 'f1or.1
72-013 A (2/91) MOA 25
011111 PAC
ELECTRIC
LICENSED BONDED INSURED
Industrial - Commercial - Residential
July 13, 1992
S & S Engineering
1704 Eagle River Loop, No, 204
Eagle River, A1217.5ka 99577
3655 Ruth Drive
99687-9201
(07) 373,4767
FAX 373.7035
This letter i8 Veilify that Harry Myr • NORTH PAC ELECTRIC,
perforwed electrical wiring services (wircithE :!.(itt station at
Lot 25, Bleck 3, Northwor,d Sub -Divi ion
Eag1.2. River, Alaka
If lufther infornvation is nest7,d, contact iixy at 373-4767.
Sincerely,
„elfw ylve',....-
MaL-ilyn E. whalsn
office Manager
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE lS`tc 3'cc 4,l
DEPARTMENT OF HEALTH AND HUMAN SERVICES -7/�
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT '7/8
PERMIT NUMBER:SW920163
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:HARVITT CHARLES L &
OWNER ADDRESS:22853 NORTHWOODS DR
CHUGIAK, ALASKA 99567
PARCEL ID:05173157
LEGAL DESCRIPTION: NORTH WOODS BLK 3 LT 25
LOT SIZE: 20046 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
DATE ISSUED: 6/30/92
EXPIRATION DATE: 6/30/93
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THIS BED SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH THE
APPROVED REVISED ENGINEER'S DESIGN DATED 6/23/92.
RECEIVED BY:
DATE: ?(/ 1/7Z
DATE
(/z
DATE : 7/ 1
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
June 23, 1992
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 L Street
Anchorage, Alaska 99501
REFERENCE: Northwoods Subdivision, Block 3, Lot 25
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
Request you issue a permit to upgrade the septic system
serving the referenced property.
Two test holes were excavated and percolation tests were
performed in the area of the proposed upgrade. Attached is
the proposed upgrade design.
This property is served by a Community water system. There
are no protective well radii which encroach upon the property.
As can be seen from the site plan this lot is large enough for
another future upgrade. We do not anticipate any adverse
effects on neighboring properties by the installation of the
proposed septic upgrade.
If you have any questions or require additional information
for your review, please contact us.
Sincerely,
ROGER J. SIAFER, P.E.
RJS/LSU/lsu
17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577
v0409L Sandal -IS 3/V
I" ; 40'
SCALE
UPGRADE
Y
SEPTIC
AREA
NORTHWOODS DRIVE
}
PREVIOUSLY ABANDONED TRENCH
V1831180 NO1S30
0
O
s
0
m
m
w
Co
N
xr
m
r
O
(r)
(J)
O
W
r
N
CI
-71
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG - PERCOLATION TEST
�Vi -rr
-N o-rii c' �-�.t .
LEGAL DESCRIPTIOrE-A?LO(4•Township, Range, Section:
SLOPE
DA
"0.R pp ryry-
TE PERFORMED: �4`a \ `Z G --
—
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
.9 H
(FEE -11---
0.
0.
. 0
c
n 1'
COMMENTS
GM
o. N
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
J6
DepthManic to W?ter-{iNer�� 4/161'
Monitoring? 1��1t�G Date.
S
L
0
P
E
SITE PLAN
-r
I
1/4N
to/ 2 , c -z -
Reading
Date •
Gross
Time
Net
Time
Depth to
Water
Net
Drop
,�, ^^�A,
�,,
'moi
-CC:
Y
& iti
- 10:WAt1.
r'
co Y-4-"
ID
cot -I i•J
CiW
si '
g
/2•
{0 :2t>
(•�y
1/�•rU%
?1l4:
t
%3I "
1/,,r
I D:40
I.
6,P 1¢..
Y2 n
PERCOLATION RATF(/v
(minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND 4
F
PERFORMED BY- S R S F±N.GtNEF_RlNG
CERTIFY THAT THIS TEST WAS PERFORMED IN
70 4 Eagle River Lo�oi Road
t�e,4 }
ACCORDANCE WITH agrTAIver/NA18SUrNir UID LI N EFFECT ON THIS DATE. DATE -
72 -008 (Rev. 4/85)
(--24 GIS
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: �4I u C I� ' ' - O I 1 ,
LEGAL DESCRIPTIONLGY'�IG L--�
Township, Range, Section:
SLOPE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
D EPTI1
(FEET)
`s
•14
•
1‘. 11/
•
•
•
r • ct
t.
•
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water Alter
Monitoring?
SITE PLAN
N
S
L
0
P
E
Date ta 61' ! !/
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
PcV.-----P12(
�-
10tospz�
1
(to -a -KZ
-z
,I
ID: i .
IU1-li1-S
lo: 26
„
4-
fa
l l
(O
10'.YII
PERCOLATION RATE I `, (minutes/inch) PERC HOLE DIAMETER
• ' TAND +
TEST RUN BETWEEN
COMMENT T2"' V--161---) •
T
PERFORMED BY -
S & S ENGINEERING
I
p17I0R34, pE7aFgqleN River�7I,�(,� Loopn�R��orad NEP
ACCORDANCE WITH t6Viiita lilaS 14 51/7 UID N EFFECT ON THIS DATE.
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE'
NIUIVIl..I1 / LI 1 Y Ur AINUhON/Mat
Dr ATMENT OF HEALTH AND HUMAN SER` ' S
Environmental Health Division
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name
DISTANCES
Address
5tz- 3 g22)e 2 -
Phone(s) Permit No.
oei3- 41-3 sty n L4-4
No. of Bedrooms
FROM TO
SEPTIC
TANK
ABSORPTION
FIELD
WELL
WELL
1^c7*
LEGAL DESCRIPTION
Lot
2S
Block
Subdivis n
LOT LINE
S
Township, Range. Section
-1-1s
FOUNDATION
2 S
TANKS
SEPTIC ❑ HOLDING
Manulacturer
Material
❑ TRENCH
Depth to pipe bottom from
original grade
Capacity in gallons
I f0 -r2
No. of Compartments
2
TYPE OF SYSTEM
❑ BEDW. DRAIN ❑ OTHER
Fill added above original grade
Gravel length
Total absorption area
Number of lines
1
installer
3,5FT
CI OFT
1D, p FT
la L(.9) SQ FT
Soil rating
2) 2 SQ FT
Total depth from original grade
Gravel depth beneath pipe
Gravel width
Distance between lines
Pipe material
?nrrMT7)2034-
Date Installed
WELLS WELLS
C✓r�j FT
Z,0 FT
610 FT
ti/jA FT
❑ PRIVATE 'OTHER (Identify)
Classification (A,B.C) \\ Total Depth Cased to
12iA-oa1)5 FT FT
Installer
Date Installed:
REMARKS:
2t »
S & 5 ENGINEERING
CRR 196)C
Municipal anEAelitEiRisM kytAKs99577
AS -BUILT DIAGRAM (Show location of well, septic system. property lines, foundation,
driveway, water bodies, etc.)
Scale: t" zLS(c)
Inspections Perfor ed by:cl—
Date: (p.
certify that This inspection was performed according to all
r Inter'
J I AUL.)
Health Department Approval: i�
ff 2
72-013 (3/85)
Date .6
'1
ENGINE
RS SEAL
r
PERMIT NO:
DATE ISSUED:
APPLICANT:
ADDRESS:
CONTACT PHONE:
LEGAL DESCRIP:
LOT SIZE:
_LJIIF ff�������
DEPARTMEOF HEALTH AND ENVIRONMENT -PROTECTION
��
825 L STREET, ANCHORAGE, AK 99501 /rAt^
264~4720 ~'
860144 UPGRADE
05/29/86
CHARLES HARVITT
SR 3 BOX 7526 NORTHWOODS DR
CHUGICK, AK 99567
688-9423
SUBDIVISION;: NQRTHWOODS
SECTION: 4 TOWNSHIP: 15N
20046 (S.FT" OR ACRES)
LOT: 25
RANGE: 1W
I certify that:
1. I am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality of Anchorage (MOA) and the State of Alaska.
2. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria of this permit,
3. I will adhere to all MOA and State of Alaska requirements for the set back
distances from any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
IF A LIFT STATION IS INSTALLED •IN AN AREA COVERED BY MOA BUILDING CODES,
THEN (1) AN ELECTRI ,RivIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS
WILL NOT BE APPROVEtYWITHOL[ AN ELECTRICAL INSPECTION REPORT; AND (3) THE
ELECTRICAL WORK ML3T BE DO CENSED ELECTRICIAN,
SIGNED 411111!���� 5� DATE: ^/�^�_
APPLICANT: C-F-
�� �� ��_��
RVITT
SIGNED
ISSUED BY
^�
u��mo /�'�_542.nz Ze15 r
DATE:
_
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
ROBERT A. SHAFER
May 21, 1986
Mun.LcLpat.L y o4 Anchonage
Depantnen. o4 Heath and Human Senv.Lees
825 L Stneet
Anchorage, Atasfza 99501
ATTENTION: Robby Robinson
REFERENCE: Lot 25; Btacfz 3; Nonthwoods Subdivision
Mn. Chuck Hanv,Ltt, S -tan. Route 3, Bax 7526, Nan.hwoods Dkive, ChugLalz,
Atasfza 99567, made app! anon thnaugh u3 4on. a Health Authontity Appnavat
on May 9, 1986. Dun.Lng pen4anmanee o4 the adequacy test a satunaved
condition existed within the trench. A6 a result we had a monitoking
tube Lvsta ted appnox.Lmatety 15 4ee-t penpend cutan 4nam the -trench and
gnaund wa-ten was monJtoned ate a pezJod o4 one week at 92 4eet. The
on.Lg.Lna2 so.L,2 tog dated June 16, 1981 neeonded a waters tenet at 10 fleet.
A penm.Lt was .issued attow.Lng a total depth o4 tkeneh o4 6 fleet. However,
at the time we per4onmed this test the total depth o4 the tneneh measured
at appnax-i-matety 7 fleet. We ane unable to detenm,Lne whether add-Ltlanat
4itt had been added on t-4 the trench was oven excavated.
The results would Indicate a waters levet at appnox.Lmatety 21/2 fleet below
the bottem o4 the existing Trench. Since this condition .i.s in non-comptiance
a penm.it appt.Leatt.on is attached 4on an upgnade a4 this system. As
soon as the upgnade wonfz has been completed the appticattan 4on a Health
Authan.ity Appnaval wiet be processed.
CIVIL ENGINEER
694-2979
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
MAY 231986
RECEIVED
14 we may be a4 4unthen assistance please contact us.
S.Lncen:ety,
T A. SHAFER, P.E.
S/ss
cc: Chuck Hanvitt
.J
4-5
1 s`
SRB 196X EAGLE RIVER, ALASKA 99577
`-(
1-t?\X.?
K1`�1r-�Gt
d1 c1 J.
use A 5 I \nl k . c R --An t•J
1/Z
' _'t
g L-G,t,J61 ( /i9')
1
S & S ENGINEERING
SR B 196X
EAGLE RIVER, AK 99577
MAY 2 11986
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG - PERCOLATION TEST
shsiv, w
Y
1457 ° r 00.tg-
Y�
61 Y [�`W.
S•Q/'lq t n���P.nr
DATE PERFORMED:` -'14,4. -' 8�
LEGAL DESCRIPTION: I. 25 , 3 NI,uR.,-Tt,l-v.kx,p5 Township, Range, Section:
SLOPE
oh.t-.t
1
2
3
4
5
7
8
9
10�
11
12
13
14
15
16
17
18
19
20
121E PL -t.
(F E'E T4
COMMENTS
5
CAM —2—c
(iL )
C1�ri(7F-�
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
lb
Depth to Water After
Monitoring? Date.
S
L
O
P
E
T 1st- �,,\4 sem. LJ'
SITE PLAN
\v N
110
7.1,7
\//
N'
fi
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
5-37- 810
'3', &S P
S 9//6
—
2
-31/SP
/P mho.
`7 -'-AL`
/ r �/Jb .,
3
3;ZSP
r/
011UJ5jt;
/ 9L."
5
'r
7"
r'/,6 "
Y3,SsP
4t,'
r'
9 7/)&,/9.5%
5/I/o "
1
4
1'`'oS10
i/5-/7
ii: /J-/'
11
(p /6„
9//,"
i/
PERCOLATION RATE _It_ (minutes/inch) PERC HOLE DIAMETER ta
TEST RUN BETWEEN T FT AND 5- FT
PERFORMED BY' led
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELI
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
EFFECT ON THIS DATE. DATE
JUN 5 1986
MUNICIPA
72-013.(Rev. 3/78)
.Tr. ' DEPARTMENT OF HEALTH & ENVIRONMENTAL. PROTECTION
- ►(, �ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/I'LL INSPECTION REPORT
NAME n
"F') iv i BEr 14 ! i
PHONE
3(16 ----ibis
----t—NEW
❑ UPGRADE
MAILING ADDRESS —
STK 120x 1/oc($1{ gr50'7
LEGAL DESCRIPTION ,, /
L. ,..5-- /3 -5 Alok 71}&) 0 cD-2,--S S/Z_
LOCATION,NO.
O r LspinC1-& .� R . +
S Com_ )<_
OF BEDROOMS
DISTANCE TO:
Well
Absorption area
Dwelling
PERMIT NO.
I- 2
w Q
m �
Manufacturer
(/� lei
Material
No, of compartments
rteto
Liq.Jcapacity in g
V r
IF HOMEMADE:
Inside length
Width
Liquid
q depth
�,.q
z
D , CE TO:
Well
Welling
PERMIT NO. /
a
2
fact
nufacturer
�
Material
Li �--apacity in gallons
ii
DISTANCE TO:
Well / /
�`{imfi�hi/� /,. ,o4t..
Foundation ,,)
Nlij - /A
Nearest lot line
/`j
PERMIT NO.
'7
6-/Z),57,5-
2
w
No. of lines I
Length f a h I ne
Total len th of lines
,�/=/�
Trench w th
inches
Distance between lines
jnes
FMaterial
O
Topof tile to finishgrade
(a )s ,
the
inches
Total effective parea ,
r�/lee//1`
in
Length \,-
Width !1,[_1
Depth
PERMIT NO.CSi
a F
Q-
Lu °-
Type of crib
Crib diameter
Crib depth
Total/effective absorptio ea
ui
w
TANCE TO:
Well
Building undation
Nearest Io;J.i e
W
Class �
/�j7/7Jb�dn.,Y//" 7gr)LQT
Depth
Driller
Distance to lot line
PERMIT NO. —
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption area(s)
OTHER
PIPE MATERIALSIA/
�L/ J
ct/ �5 �(Gr _wi)z-
SOIL TEST RATING
/ Lc-- -C/. -74/Z;eir 11,1
o
INSTALLER
L kee C____
o v e
a
REMARKS /14,1 /MONO&
7
-
r�
o
(.L>Rs -772/ a 7 G'�/-�i��
Fes,- .,i), ---/z. sai
,�A-
��'�
�'
G
APPROV D LEGAL
VL.L -1 C?
Ifi<-'('. 7 DATE VG�� �l Gcc/
72-013.(Rev. 3/78)
9 " ,11 , y M.-- Ar.. o zr �/^
DEPARTMENT i �HEHLTH AND ENYIRONMENTHL� .OTECTION
`r'
825 'L STREET/ ANCHORAGE, HE 99501
264~4720
PERMIT NQ ( 810557 )
P_O (�
APPLICANT FRANK BETHHRD STR BOX 1698K
LOCATION PETERS CREEK
LEGAL L 25 B 3 NORTH WOODS S/D
TYPF OF SOIL ABSORPTION SYSTEM IS: TRENCH
q9507 345-1615
LOT SIZE 200r0 SQUARE FEET
MAXIMUM NUMBER OF BEDROOMS = ] SOIL RATING (SQ FT/BR)= 195'
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
�
��F���1� �
� ����3��= �� ����vEEAL
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD.
THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
����17.7: EEC. 7E -3E: 1: g2'; 1FF-7u rA 6-‹ a'. ��C.En PI��������
`
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THISDEPHRTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY-NELLS.HDJHCENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES' THAT THE WELL WILL SERVE.
~_— "TWO IPAS:F="F=FIRDPA:S FIR:1E FZEDIDUIF2E:CH
BACKFILLING OF ANY SYSTEM WITHOUT^FINHL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTIOU
MINIMUM DISTANCE
BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL
MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND
TO A COMMUNITY SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTHLLHTIQR
�E2 ri 1- I ��: 117.- �����
I CERTIFY THAT
1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CQDEa
3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS
SIGNED:
APPLICANT FRANK BETHARD
ISSUED BY
�^'�� g�
�DHTE_��_�a-Y4.0
Applicant:
UNICIPALITY OF ANCHORAGE
Department Health and Environmental\-2rotection
825 L Street, Anchorage, AK. 99501
264-4720
* * * HANDWRITTEN PERMIT * * *
WELL AND/OR ON-SITE SEWER PERMIT
Mailing Address: 54/g /6 94:,t
;'42
Location:
Legal Description: cS/r
Type of Soil Absorption System Is:
Trench: Drainfield:Seepage Bed: Holding Tank:
Maximum Number of Bedrooms: Soil Rating(sq.ft/br)
Phone Number:
of Size:
0, ©o
The Required Size of the Soil Absorption System Is:
DEPTH LENGTH 7C101., GRAVEL DEPTH WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet). Al\
* REQUIRED SEPTIC(HOLDING) TANK SIZE = Gn U GALLONS * *
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
* # * TWO(2) INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final inspection and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 3 1
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence ism emoed,9to include more that jbedrooms.
Signed:
Ap2icant
swP/024(1/81)
Issued by:
Date:
PERFORMED FOR:
_,JIUNICIPALITY OF ANCHORAGE \-.-'
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Pouch 6550, Anchorage, Alaska 99502 2762221
SOILS LOG — PERCOLATION TEST
F rain k l3ea laA
LEGAL DESCRIPTION:
PERCOLATION
TEST
DATE PERFORMED: k -16 _91
1—of 2 5 131 k 3 North woods Ei :
LovutA 4k64
SLOPE
WAS GROUND WATER S
ENCOUNTERED? P.5 1
O
IF YES, AT WHAT
DEPTH?
P
E
tO
SITE PLAN
L
ati
1
1
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
3 314
19//6
o
0
33,4
o
4 `/2
6//6
to
to
41k
3/4
5 A
646
Zo
10
5A
3/4
6
646
30
10
6
3/9
7 `/2
64
b 0
30
7 I/2
1 Y2
PERCOLATION RATE
q
//� TEST RUN PETWEEN
COMMENTS t 5- IJ 7 ft . __AA _AA 06-7,4
PERFORMED BY:
/6
4 1FT AN,utes/inch)
FT
1
•
*Ad 3 3j
CER T:FIED BY:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I D #
1. GENERAL INFORMATION
HAA # OiZc\ 1-0)1
Complete legal description Lot 25; Block 3; Northwoods Subdivision
Location (site address or directions) 22853 Northwoods Drive
Property owner Harvitt Day phone 688-9+-23
Mailing address
Lending agency Day phone
Mailing address
Agent Sharon Minsch — RE/MAX OF EAGLE RIVER Day phone 694T4200
Address 16600 Centerfield Drive, Suite 200, Eagle River, Alaska 99577
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
3
XXX
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
xxx
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA 7121
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm S & S -ENGINEERING Phone
17034 Eagle River Loop Road No. 204
Address Eagl
Engineer's signature Date I ����Z
6. DHHS SIGNATURE
X Approved for 3 bedrooms.
Disapproved.
tea.474.1.4hv
.; �E OF. 4 4'11vs
„
/ '• s7 •4. a9
of* / 491►t ,� b� * 0
••°g NN
stn S ROGEIR J. No.8S5AFER ...4:10" �": w?
"
14"ildPRO FESSt°N;e7
e/11Pts.1:100"v
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
By• ��%1.s.{�Q.
Date 7 - 2 ¢ - '2
CAUTION
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025 (Rev. 1/91) Back MOA 921
Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: 4vg1-1-11A-I•cc5
Parcel I D I��I��
A. WELL DATA
Well type If A, B, or C, attach ADEC letter. ADEC water system number -19.�1IT7 21-06
/
Log present (Y/N) Date completed Driller
Total depth Cased to Casing height
Sanitary seal (Y/N) Wires properly protected (Y/N)
Date of test
Static water level
Well flow
Pump level
FROM WELL LOG
gpm
AT INSPECTION r
zTs
t")Z D
co 0
9Pm• •
<a
F-3 z
O
Zn
0 m
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot 200' On adjacent lots
Absorption field on lot 'j ; On adjacent lots
Public sewer main Public sewer manhole/cleanout
Sewer service line Petroleum tank
WATER SAMPLE RESULTS:
Coliform Nitrate Other bacteria
Date of sample: Collected by
B. SEPTIC/HOLDING TANK DATA
Date installed - l46
Tank size !Ooo
Cleanout N) 7 Foundation cleanout (Y N) LI Depression ( Y
High water alarm (Y/N) IJ'•P
Date of pumping %Jq1„---
Compartments
Alarm tested (Y/N)
Pumper 1 i�r✓t (I,jGI
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot
On adjacent lots 2 Foundation
To property line 20 Absorption field 42 Water main/service line I b (4-
Surface water/drainage bb
72-026 (Rev. 7/91) Front
CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons
Ven
-4-)9 1
Manufacturer
Manhole/Acces
N)
High water alarm level
"Pump on" level at o- "Pump off" level at le
��" Cycles tested
Meets MOA electrical code (Y N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot
D. ABSORPTION FIELD DATA
On adjacent lots
/r
Surface water (dd +
Date installed �l2 Soil rating O. System type •
Length -2(p Width Gravel thickness b•S Total depth 2
Total absorption area 2--.11=1 Cleanouts prese
Depression over field (Y
Results (pass/fail)
Peroxide treatment (past 12 months) (Y
Date of adequacy test
for
k•1
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot
To building foundation
bedrooms
If yes, give date
On adjacent lots �d -I- Property line 2. -
To
To existing or abandoned system on lot
1D` -1 -
On adjacent lots2Jb � Cutbank ' Water main/service line (D /
gib'
Surface water j66 � Driveway, parking/vehicle storage area
Curtain drain lL-- C'1/-ir •
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect Qra�clate of this inspection.
ig470 vVvAW
e °9OOfA000R 40 / u
0
t3" e9 oo m
0 tiz 493 °Y as{ d
00%,X0000000000 00000 aB00 p 0 0
s0 a 000000 8ba a$®B
0�\ ft©GE J.. HAFER / &9'
4 e No,8 15 r
0114;....
°(N6.411'.:1'
g�t�'8�00 eo11% PROF °°04.°''c'w
e000°°
s & 5 ENGINEERING
Signature 17t5�q Cay'ver l.00l) Road No.20d
Engineer's Name yie River, Alaskal99577
Date —1 � \ —1 -92--
1 76.4`
HAA Fee $ /
Date of Payment 7/4?2 ,/
Receipt Number ata p `J-4-4/4>
72-02fi (Ray. 3/011 Back MOA 21
Waiver Fee: $
Date of Payment
Receipt Number
r� �..`.�i 7 i ��::�. :i I, rj (6.1 ` �' 1M'
, 1 ' i` (� �ti;� �� i' 1 I
OJ J Lr a i LL.::, U( IF !.r I .: t' K`)ti
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE DISTRICT OFFICE
800 E. DIMOND BLVD., SUITE 3-470
ANCHORAGE, ALASKA 99503
FOR: Roger Shafer
S & S Engineering
April 6, 1992
PWSID # 213001
WALTER J. NICKEL, GOVERNOR
(907) 349-7755
My review of the records on file in this office reveals that the Northwood Subdivision Class
"A" Public Water System, is in compliance with the routine coliform bacteria sampling
requirements listed in Table C, and with the inorganic sampling requirements listed in
Table B of 18 AAC 80.200.
Sincerely,
Sc-( Byron Roys
Project Engineer
BR/cf
b y C.D.
A
I•
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date May 9, 1986
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 25; Block 3; Northwoods Subdivision Unit #1
Location (address or directions)
7526 Northwoods Drive
(b) Applicant Name Chuck Harvitt Telephone: Home 688-9423 Business same
Applicant Address SR 3, Box 7526, Northwoods Drive, Chuaiak, Alaska 99567
(c) Applicant is (check one): Lending Institution ❑ ; Owner/builder ®; Buyer 0 ; Other 0 (explain);
(d) Lending Institution Alaska -Mutual Bank Telephone
Address Anchorage, Alaska
(e) Real Estate Company and Agent none/refinancing
Address
Telephone
(f)
•
1412.
the HAA to the following address:
S S P.ngi nperi ng
SRP 196X
Eagle Rivpr, Alaska 99577
2. TYPE OF RESIDENCE
Single -Family ® Multi -Family 0 ' Other
Number of Bedrooms 3
3. WATER SUPPLY
Individual Well 0 Community IC] Public 0
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite i Public 0 Community 0 Holding Tank 0
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
72-025 (11/84)
Page 1 of 2
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm S & S ENGINEERING Telephone 6'- 2-?? 9
SR B 196X
Address
Date
EAGLE RIVER, AK 99577
6. DHEP APPROVAL
Approved for
Approved
Terms of Conditional
(4)
/2--4bd'drooms by
Disapproved
Approval
Rol cA R. Shag
.a ka. 1474 40--or-
0,,,<%,°,..., * •<
PS - To se...eee0'je �.144,,, _Pita FEBS‘C314r
Conditional
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11/84)
A. WELL DATA
Well Classification
A
MUNICIPALITY OF ANCHORAGE (MOA
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720 ���
Legal Descrip ion. 25
r912-er
Well Log Present (Y/N)
Total Depth Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
u[ri. 'Jr f7CNLlr1 64
ENVIRONMENTAL PROTECTION
N G 6 1986
If A, B, C, D.E.C. Approved 7N)
Date Completed Yield
h of Grouting
Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
Zara Ik
To Nearest Edge of Absorption Field on Lot
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer Line To Nearest Public Sewer
Cleanout/Manhole
To Nearest Sewer Service Line on Lot
Water Sample Collected by ; Date
Water Sample Test Results
Comments
ire, 21363v1
B. SEPTIC/.14-etatNG TANK DATA
Date Installed 1 —1\—g) Size No. of Compartments -2—
Standpipes
StandpipesN) Air -tight CapsON)
N)
Depression over Tank (Y/TP
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High -Water Alarm (Y/N) rI� Ix
Separation Distances from Septicg Tank:
To Water -Supply Well
To Property Line
2e�( 4-
12-0
-
I
To Water Main/Service Line
Course
Comments
l�
Foundation Cleanout (Y/N
Date Last Pumped \—'
for
Temporary Holding Tank Permit (Y/N)
To Building Foundation
To Disposal Field
)i4
1,0 I
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata 0I6/L
Date Installed (0 —6-- ` lo
Width of Field
Type of System Design t):7 -,A,
Length of Field
Depth of Field
Gravel Bed Thickness
Square Feet of Absorption Area � Standpipes Present 4DN)
Depression over Field (Y/f Jp Date of Last Adequacy Test
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water -Supply Well To Property Line
To Building Foundation rLCo To Existing or Abandoned System on
Lot \ ; On Adjoining Lots 'tan 1-{-
To Water Main/Service Line r> ` To Cut ank (if present) I P
To Stream/Pond/Lake/or Major Drainage Course N A
To Driveway, Parking Area, or Vehicle Storage Area X01
Comments A. 121,--4 Wl -rev .),). Pt.) i f? -1 A -ME Sx 1S�trJG 1� �� Capt w�5
•t-taJ r.0 --ro
N - S• f G ,M WP -5 \
D. LIFT STATION
Date Installed Dimensions
Size in Gallons Manhole/Access (Y/N)
"Pump On" Level at "Pump Off" Level at
High Water Alarm Level at Vent (Y/N)
Tested for Pumping Cycles during Adequacy Test. Meets MOA
Electrical Codes (Y/N)
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify tgat Ihae check�eEklNfiied, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed sitsttt C' DateJUN 51986
ComparApLE_R[V I(99577 MOA No Xr--3
Receipt No '72)9 eltoa.
Date of Payment G--(.0-6
UC
Amount $
Page 2 of 2
72-026 (11/84)
• h.ri
,r
I •Y
C -
-
L LL/L
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE/WESTERN DISTRICT OFFICE
437 "E" STREET, SUITE 303
ANCHORAGE, ALASKA 99501
DATE: May 16, 1986
PWS I.D.# 213001
BILL SHEFFIELD, GOVERNOR
Telephone: 1907)
Address:
274-2533
To Whom it May Concern:
According to records on file in this office the NORTHWOODS
Water System is in compliance with the State Drinking
Water Regulations
Sincerely,
Steven ,- ng, PE
District Engineer
Time'
Timei_.
;e
Date
Date
Date
Inspector
Inspector
Inspector
Comments
eV 3 .110 -44 -44N-
9 -c 2-- ---16r-1)'2
6.420
Conditional Approval
Date Sewer Installed
Permit No.
Septic Tank Size
Holding Tank Size
Soils Rating
Well To Absorption Area
Well to Tank
Well Log Received
APPLICANT FILLS OUT LOWER .HALF ONLY
Property Owner Uethard Construction, inc.
SPA Pox 1698-K, Anchorage, AK 09507
Mailing Address
Phone
345-1615
Buyer Charles L.- and Evelyn L. Harvitt
7432 SW Miles Place, Portland, OR 07219
Address
Lending Institution Alas ka. Mutual
Denson and Minnesota
Address
Phone
Realty Co. & Agent PE%`M2-Y Properties, Inc. attn: Will Eason ,
2702 Gamhell St., suite 101, Anchorage, AK 9950/
Address
Phone
T76--2.761
Legal Description Lot 25, Block 3, Tlorthwoods
NIIN North Woods Drive
Street Location
Type,gf Residence
C? Single Family
❑ Multiple Family No.
❑ Other
3
of Bedrooms
Water Supply
lcIndividual ATTACH WELL LOG. A well log is required for all wells drilled since June
Community 1975. For wells drilled prior to that date, give well depth (attach log if
❑ Public Utility available.
Sewage Disposal
ti Individual Year Individual
❑ Public Utility When
❑ Holding Tank
- 1981
Installed:
Connected to Public Utility
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
ALASKA CfUIROn1n6nTAL COfTROL sCnUICCs, inc.
engineering & 6nuironmental Studies
MUNICIPALITY OF ANCHORAGE
CP HE,';='i
ENVIE is+'-1JfA. iO E TDC`
E 1=S tt 1982
RECEIVED
January 29,1892
Mr. Les Bucholz
Department of Health and Environmental Protection
Pouch 6-650
Anchorage, Alaska
99502
Attn: Les Bucholz
Dear Les:
On the 29th day of January 1982, Alaska Environmental Control
Services Inc. inspected the on-site sewage system for 5 homes
located at Northwoods Subdivision.••Lolock 3
Lott 100 Block 3
Lot 13 Block 1
Lot 16 Block 4
Lot 12 Block 1
In my inspection I found a cap missing, and final grade,
needed for Lot 12 Block 1. All construction of the sewage
systems, except for Lot 12 meets Municipality of Anchorage
code. All had dry sump pipes.
If you
have any gue§:ti ase contact me.
�opp <Qa aQoc�Qc"�7. Sincerely;
.V1 4Jw. O i'� � �a�
I
g000
00
opt) o
,s �,, C. Rid, dr. ; �, �; eroy C. Reid Jr., PhD, PE
lvt,QaQ
nZ:f ice. 22 1. . t�`f President
• 6 C0 `-
RUFESSl3 1
1220 UJest 25th Auenue • Anchorage, Alaska 99503 0 (907) 276-1361