Loading...
HomeMy WebLinkAboutHENKINS BLK 2 LT 7 unicip lity of nchor ¢ Department of Health and Human Services 825 "L" Street Torn Fink, Mayor P.O. BOX 196650 Anchorage, Alaska 99519-6650 343-4744 August 3, 1992 Alaska Housing Finance Corporation PO Box 101020 Anchorage, Alaska 99510-1020 Subject: Lot 7 Block 2 Henkins Subdivision Permit ~SW910223, PID ~051-292-10, The subject permit, issued August 1, 1991 by this office for a single family well and/or on-site wastewater system, has expired as of Auagust 1, 1992. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be .sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $200.00 for an on-site wastewater permit; $75.00 for a well permit and $275.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sincerely, / J J~n Smi~, P. E.~/ ~rogram.~anager On-site Services enc: Copy of Permit MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW910223 DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES OWNER NAME:ALASKA HOUSING FINANCE CORP OWNER ADDRESS:P.O. BOX 101020 ANCHORAGE, ALASKA 99510-1020 DATE ISSUED: 8/01/91 EXPIRATION DATE: 8/01/92 PARCEL ID:05129210 LEGAL DESCRIPTION: HENKINS BLK 2 LT 7 LOT SIZE: 20038 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: Tom Fink, Mayor ] unicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 August 1, 1991 Lou Butera, P. E. Eagle River Engineering Services PO Box 773294 Eagle River, Alaska 99577 Subject: Waiver Request for Lot 7 Block 2 Henkins Subdivision Waiver Request ~WR9100033, PID~ 051-292-10, SW910223 Dear Mr. Butera: Your request for waiver of the required 10 foot separation between a septic system and a lot line has been approved. waived distance is 0 on the (front) north property line abutting the road right-of-way (Old Glenn Highway). The This approval applies to the existing septic system lot line separation only. Any future upgrade to the septic system will require all separations be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services Concur: /~ ~"¢ohn Smith, P.g,~/ Program Manager On-site Services ljw#7 Registered Civil Engineer July 22, 1991 John Smith, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Lot 7, Block 2, Henkins Subdivision Narrative Dear Mr. Smith, The proposed septic upgrade will have very limited impact on adjacent properties for the following reasons: 1. The area has % acre lots and a community water system allowing sufficient room for septic sites. Most lots front the highway reservation and therefore have replacement areas. 2. Immediate neighboring lots have septic systems or wells in place. 3. Reserve space is adequate, due to absorption capacity. Soils are very adequate. 4. Drainage will not be effected and is not a major consideration in our design. We are requesting a zero lot line setback to the front (North) lot line to allow placement away from a community well to the South. The property to the North is a highway reservation, and placement of the septic system will not impact the area. Existing leachbed was excavated into and there is no significant septic deterioration of the soil surrounding the leachfield. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. . ~ EXISTING LEACHBED TI] BE ADANDDNED, / ~- / r--- EXISTING 1000 GAL TANK TB BE /~.~" / / REMDVED ANND REPLACED WITH AN / ~' /... /..~ / / ANCHBRAGE TANK 1250 GAL SEPTIC / ~ ~' /~0' / / TANK/LIFT STATIDN. - ~ ~ ~ ~/~ / / ~~NEIGHBBR'S LEACHBED / ~ ~ ~ .... / ~/ ~CANT CLAS 'A' WELL ~ - TEST HOLE · - ~ONITOR TUBE o - SE~ER CL~NOUT ~ - ~ELL ........... PROPOSED L~CHFIELD NO KNOWN CURTAIN DRAINS ~ EASEMENT SEPTIC SITE PLAN ~so[ ~( _~ LEGAL: LOT 7 BLOCK 2 HENKINS SUBDIVISION OWNER: A.H.F.C. CONTRACTOR: N/A JOB ff 9~-0~11 DAT[: 07/~9/9~1 SCALE 1" = ~0' EAGLE RIVER ENGINEERING SERWCES P.O. Box 773294 EAGLE RIVER, AK. 99577 EAGLE RIVER ENGINEERING SERVICES P. O. Box 773294- EAGLE RIVER, ALASKA 99577 Phone 694-5195 SHEET NO. OF CALCULATED BY L .B. DATE 07/22/91 CHECKED BY DATE SCALE Soil rating iSP~ __... : - . . ~501=~37~squar~feet '~ i i '~ i Y wide~system.i..2.J'..gravet, i :-~ ~ ~ i i i i ....... ,,~f ::':.t ,:.~. .... ~. i i i'.'.'..'..'.'.'..., i i ....... ......... LEGAL: SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LOT 7, BLOCK 2, Henkin~ Subdivision Ao GENERAL 1. The well and septic plan are for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified or modified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. Bo TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 3.5' at any point. 4. The sewer line is to replace the existing sewer line that leads to the existing bed. 5. The trench gravel is to be covered with typar fabric material. 6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leach field. 7. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH = 3.5' GRAVEL DEPTH = 2.5' TRENCH LENGTH = 48' TRENCH WIDTH = 5' SOIL RATING = 1.2 GPD/ft2 BEDROOM CAPACITY = 3 SEPTIC TANK SIZE = 1,250 gallon Anchorage Tank with lift station wired by licensed electrician. Twenty-four (24) hours notice required for aH inspections. NOTE: Insulate with 35psi burial foam and 6" soil mounded above grade. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1,._,~'~ 2 3 4 5 6 7 8 9 SLOPE SITE PLAN 10 11 12 13 14 15 16 17- 18- 19- 20 WAS ~ROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH7 Gross Net Depth to Net Reading Date Time Time Water Drop .~ .- ~ ~e~" ~_~" PERCOLATION RATE ~' ~'' (minutes/inch) TEST RUN BETWEEN ~,~ FT AND '~ , FT COMMENTS DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ( ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE [~NEW LEGAL DESCRIPTION LOCATION NQ. OF BEDRQQMS Well Absorption area / Dwelling ~ PERMIT~O, ~ ~ DISTANCE TO: '~ / ~ ~ Manufacturer C~ Ma~C, No. of c~partments Liq. capacity in gallons Inside length Width Liquid depth /~)~O IF HOMEMADE: ~ _ ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. O z ~ Manufacturer Material Liquid capacity in gallons ~ Well Foundation Nearest lot line PERMIT NO.  Z No. of lines Length of each line Total length of lines Trench width Distance between lines ~ inches ~ -- Top of tile to finish grade Material beneath tile Total effective absorption area ~ inches PERMIT NO, m Length ~ / Width i~,/ Depth ~ T~rib C~,er C~ d~;th Total ~ { Well ~ B~ilding fau~dation Nearest lot line ~ DISTANCE TO: ¢~ z ~ ~ Class Depth Driller Distance to lot Hne PERMIT NO. ~ DISTANCE TO: Building foundation Sewer line / Septic tank r Absorption area(s) OTHER PIPE MATERIALS SOI~ T[ST BATING INSTALLER REMARK8 OVED DATE LEGAL PERMIT NO. ( p-;,mq?¢. -.-, - "~1'1- "' '- ' _ RPPLICRNT BL LHR__N,.RU_-.TIC HOMES LOCRT I ON LE.~HL L7 B2 :HENKINS TYPE OF '~AIL MB_,URFTIUN z,Y_,TEM IS: DRBINFIELD r-li_i~-~ I C: I [ ~LIT"~ iliF t=~-~CH F~I3E DEPBRTMENT OF' HEBLTH BND ENVIRONMENTBL PROTECTION 825 'L' STREET, 8NCHOR8GE, BK. 9950~ 264-4?20 SE~4ER F'iF-~r.~ I T PO BOX 594 ERGLE RIVER 99577 MRXIMUM NLIME:ER OF BEDROCMS = 2; 694-9555 LOT SIZE 999999 S~]LIRRE FEET SOIL RRTING (SD FT/BR)=~,¢'=._, THE REG!UIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS: [-"E PT H = 5 L E !'-.! G Tt I---'. 5-1 13 F-: I--] "-.-' E L DEPTH= 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE EXCRVBTION (IN FEET). THE TRF~-~C:I ! klIDTH IS 5. ~30~3 FEET_ THE GR~VEL DEPTH IS THE MINIMUM DEPTH OF GR~VEL BETWEEN THE OUTFBLL PIPE ~ND THE 80TTOM OF THE EXCBV~TION (IN FEET). t~-:F'~J.l_~ T RE[) SEPT I £: TRf-~i-~ S I ZE= 1888 PERMIT RPPLICRNT HRS THE RESPONSIBILITb' TO INFORM THIS DEPRRTMENT DURING THE INSTRLLRTION INSPECTIONS OF RN'T' WELLS RDJRCENT TO THIS PR_PERTh' '1] ' ' RND THE NUMBER OF REc, IDENCEm THBT THE WELL WILL SERVE. T 14 i]l ,:: '-: _ Z t, I I'-~SF"E£:T I ;]I'-IS RI~:E REL--~-~L~ I BEC:, BRCKFILLING OF FIN~' _~_.TEM WITHOUT FINRL INSPECTION FIND BPPROVI-]L BY THIS DEPRRTMENT WILL BE qUBJECT TO PROSECUTION. MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS t00 FEET FOR R PRIVRTE WELL OR i50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEET 8ND TO ~ COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MB9 BPPLY. SPECIFIC8TIONS 8ND CONSTRUCTION DIBGRBMS 8RE BVBIL8BLE TO INSURE PROPER INST8LL8TION. PEF.:f'I I T E)<F' I RES DEC:EMBER I CERTIFY THI=IT 1: IRM FRM!LIBR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPRLITY OF RNCHORRGE. 2: I WILL INSTRLL THE SYSTEM IN RCCORDFtNCE WITH THE CODES. 3: I UNDERSTFIND THRT THE ON-SITE SEHER SYSTEM MR'¢ REQUIRE ENLRRGEMENT IF THE sRESIDENCEI,-,NED :_ IS INCLUDE MORE TH N , , RPPLICRNT RL LNR_,JN,. RU_,TIU HCME=, ISSUED B'T' -- ...... [:'RTE___ ~ [] SOILS LOG PERFORMED FOR: LEGAL DESCRIPTION: 3 4 ~5 6 7 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST [] PERCOLATION TEST SLOPE FE PLAN 10 11 12 13 14 15 16 17 18 19 2O COMMENTS ENCOUNTERED? O IF YES, AT I/VRAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE TEST RUN BETWEEN CERTIFIED Fj AND I// ' v (minutes/inch) -- FT DAT E~/~I~ I ' ApPLIC'"NT FILLS OUT UPPER HALf'ONLY Prop_erty Dwner Phone Alan A. Larson~ Helga Larson 694-2509 'Mailing Address P.O.Box 594, ]~agle River AK ZipCode 99577 Buyer Unknorm Address Zip Code Lending Institution Phone Unkn own Address Zip Code Realty Co. & Agent Phone l~ommonwealth Area, Inc. Realtors (Helga) 694-9555 Address P.O. BOX 249, Eagle River AK zip Code 99577 Legal Description Lot 7, Block 2 Henkins Sub Street Location Henkins Dr. Type Of Residence ~Single Family [] Multiple Family No. of Bedrooms ,-, [] Other Water Supply [] Individual ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. KCommunity For wells drilled prior to that date, give well depth (attach log if available). Public Utility [~(Individual Year Individual Installed: [] Public Utility When Connected to Public Utfldy: [] Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Date Date Date Date --f'Z'_ / Inspector Inspector Inspector Inspector Field Notes: J U L 0 1 1983 r: ............. ~: of Ar.,chorage" "Dspt. cf ........ ( /,~'PROVED BEDROOMS ~,~ tCONDITIONS OF APPI~,~m~g.,,T~al ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* DATE __ 7-- ~'"'- ,t If Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received 2/:' "~ Well to Tank Septic / Tank Size