HomeMy WebLinkAboutJUNIPER VALLEY BLK 4 LT 2Juniper Valley
Block 4
Lot 2
#050-751-47
�sr« & COLE
oecoaos
4P.O. Box 670269, g
RLL VA�IWATER WELLS
www.suilivanwaterwells.com
Pump Installation Log
Well Drilling Permit Number: SW 070263 Date of Issue 9-26-07
Parcel Identification Number: 050-751-47
ILegal Description
Juniper Valley Lot 2 Block 4
Pump Installation Date: 8-4-15
Pump Intake Depth Below Top of Well Casing: 480
Pump manufacturer's Name: Grundfos
Pump Model: SSQE35-450
Pump Size: 1.5
Pitless Adapter Burial Depth: N/A
Pitless Adapter Installer: N/A
Disinfected Upon Completion? ® yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments:
Pump Installers Name: Sullivan Water Wells
Property Owner Name & Address
Spinell Homes
1900 W. Northern Lights Blvd 6200
Anchorage, AK 99517
feet
r,
feet
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Municipality of Anchorage V MAYO 4 Lu,
Community Development Department Page of
On -Site Water and Wastewater Program
4700 Elmore St. ° P.O. Box 196650 Anchorage, AK 99519-6650 ° http://www.muni.org/onsite ° (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SWO70263 PID Number: 050-751-47 ® New El Upgrade
Name:
JEFF & SUSAN LAKOMSKI
ABSORPTION FIELD
®Deep Trench El Shallow Trench El Bed ❑ Mound
Address
PO BOX 771445, EAGLE RIVER, AK 99577
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
1.2 GP D/SF
10 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
6 Ft.
Gravel depth beneath pipe
4 Ft.
Subdivision Block Lot
JUNIPER VALLEY 4 2
Fill added above original grade
unk Ft.
Gravel length
47 Ft.
Township Range Section
Gravel width
2Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
375 + Ft
1
NAFt,
Well
TANK ❑ Septic 0 S.T.E.P. ❑ Holding ❑ Other
100'+
100'+
NA
NA
25'+
Manufacturer
Anchorage Tank
Capacity
1250G,1.
Surface Water
100'+
100'+
NA
NA
NA
Material
Steel
Number of compartments
2
Lot Line
5'+
10'+
NA
NA
FoundationLIFT
STATION
5'+
10'+
NA
NA
Manufacturer
Capacity
Curtain Drain
NA
*50'+
NA
NA
Anchorage Tank
1250 Gal.
Remarks *None known. Existing well. No house built.
Pump on level at
in.
Pump off level at
in. I
High water alarm at
in.
No components installed in STEP. System built per
design with final inspection, elevations & as -built
Pump make and model
Electrical Inspections performed by
pending owner notice to proceed.
Installer
PIPE MATERIAL House to tank D3034 Tank to D3034
drainfield
R.P.C.
Drainfield D3034 COIMT D3034
Inspector ArcTerra Consulting, Inc.
BENCH MARK (Assumed elevation) --ft
Inspdates: 1 ° 10/2/2007 d 10/03/2007
Location and description
2
3'd Pending 4'"
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
/ Y' _ r
'"� OF �:44
Conditional Approval: .':.��'Z�''' Date ��'r� ,rr-'P��,a••°°°�,���
-� _�
F[3147N`. •��
°ao�n`3
it i U,
aenoaas0y0 000 0o xo
Y
F UI
ell V,&V .,w.
eli a j �..e. °
.0,
vvv® .0,O Kang , rv{. Uui 4�
CE
7116 le 'A
�� 9F� `6
e(i Date
ApproCE
p a`F�"" P�'
AO 11?
Inspection Report_1-1-12.doc
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.orglonsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SW070263 PID Number: 050-751-47 0 New ❑ Upgrade
Name:
ABSORPTION FIELD
Spinell Homes
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
1900 West Northern Lights Blvd
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
GPD/SF
8 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4 Ft.
Gravel depth beneath pipe
- 4Ft.
Subdivision Block Lot
Juniper Valley 4 2
Fill added above original grade
- 0 FL
Gravel length
47 Ft.
Township Range Section
Gravel width
Ft
Fc
Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
-
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
376 Ft=
1
NIA Ft.
Well
111.8
149.0
118
N/A
25+
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,000Gal.
Surface water
100+
100+
N/A
N/A
Material
Steel
Number of compartments.
2
Lot Line
83
100+
83
NIA
NA
Foundation
122
164
N/A
N/A
LIFT STATION
Manufacturer
Orenco
Capacity
250Gal.
Curtain Drain
50+
50+
NIA
NIA
Pump on level at
Pump off level at
Her waTer�larm at
Remarks * See Inspection report by Arc Terra. PES
40 in.
36 in.
}
��" 5in.
performed a record survey to close out permit for
Owner. This report IS for what PES found. For all other
Pump make and model
P2005-1
Electrical Inspections perform by
twikVA,0l�1ti
info see Arcterra's Report
PIPE MATERIAL Hou eto Tankto"
drainf
Installer
Unknown
Drainfel O/MT 3034
Inspector PES
BENCH MARK (Assumed elevation) 100ft
Inspection i
1s 6/6/2016 6/28/2016
Location and description
dates: 2�a
Garage FF
sb 4,n
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
oT�\NN,
+s O� q��
Conditional Approval: Date
!4�,
••" •
��ey0
�,:S
W.�n'
A r - ed Date
InspectidLi F3cffSbrt_1-1-12.doc
Municipality Anchorage
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
�lrenr
c ,
Department
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSV161085 COSA#: OSC161305 Permit#: SW070263
PID#: 050-751-47
Legal Description: Juniper Valley Block 4 Lot 2
Engineer: Pannone Engineering Services
Applicant: Spinell Homes
The following separation distance waivers are approved.
1. 29 feet between the drainfield and a 25 percent or greater slope.
This waiver approval applies to the existing drainfield only. Any future upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver.
❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected
adjacent property.
X Adjacent properties are not affected by this waiver.
...............................................................................
Waiver is Granted: / X Waiver is not Granted:
Date: �o ( Approved by:
a e of Reviewer
................................................ .............................
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panenaak.com
July 26, 2016
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. 0. Box 196650
Anchorage, Alaska 99519
Subject: Juniper Valley, Block 4, Lot 2
Septic System to Steep Slope
Waiver Request
Ladies and Gentlemen:
I am writing to �X= est a sfeparat�n dis nce waiver between the proposed septic system and a slope of
greater than 25feet (29').
�� n ? h Q
The soils in this area ar ypicall rologic Soils Group A which contains organics underlain by
poorly graded gravel and s Record information shows a percolation test on the proposed
lot and found a percolation rate of one point five minutes per inch (1.5 mpi). The soil
composition and percolation rate confirms the soil classification of HSG A.
Due to the nature of and drainage capacity of the soils found in the area (HSG A) the designed
infiltration line of 45% for septic system installation on steep slopes should be used instead of
the assumed/worst case soil classification infiltration line of 25%. The slopes and soil types
enable installation of any conventional system without the system effluent "daylighting"
further down the slope of the hill provided bury depth requirements are met.
Granting this waiver will not pose a threat to the safety of this lot or the surrounding lots.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
Please contact me if you have any comments or concerns.
Sincerely,
Steven R.
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments:
-Site Plan
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
�o'la
ALLoy, TRENCH
x 4 E x 8'TD) Yn/
'Al.
� I
I
M
\��
1,250 al STEP TANK
TRUE NORTH SCALE : t"= 50'I
\LS TI 1 49.0 LOT 2
V 111.8 \
\ DRIVEWAY C1
\
\ WELL E
\ NOl
\ A
\ I
V B 3BR /
\ \ SFD /
\ \ Al
NOTES:
RECORD DRAWING
DRAWN I NJC
SITE PLAN
PANNONE ENG SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
JUNIPER VALLEY, BLOCK 4, LOT 12
SPINELL HOMES INC.
3945 MARIAN DR.
EAGLE RIVER, AK 99577
/
{.�
A
B
FC
20.9
6.1
C 1
87.9
86.0
T1
123.8
1225
LS
1317
129.9
M1
164.3
171.3
M2
206.1
212,4
NOTES:
RECORD DRAWING
DRAWN I NJC
SITE PLAN
PANNONE ENG SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
JUNIPER VALLEY, BLOCK 4, LOT 12
SPINELL HOMES INC.
3945 MARIAN DR.
EAGLE RIVER, AK 99577
/
{.�
7/27/2016
Scale
•
P.I.D. NO
Ali. re
050_-_751-47
_
h OAA
CE 8149 .•
PERMIT N0.
SW070263
1 OF 2
SPECIAL PROVISIONS TO SPECIFICATIONS
NGINEERING AND SURVEYING DESIGNED AND INSPECTED STYSTEM. PES IS
VENTING WHAT WAS FOUND DURING SITE INVESTIGATIONS.
SEWER GRAVEL 6"
ABOVE PIPE INVERT
4" m PERF PIPE NO%
FILTER FAERIC�j I
c SRPt,ON
25 `N,1lTNUR uPs NEI I SEWER
sR E Ns � GRAVEL
4pGo 5 ANeVL ' _
Op,
—5c]
o FILTER FABRIC m
o_ -p o o o �
SEER GRAVd o" ABOVE PIPE INV �
a
2
r s / z
x1.125' m DRAINPIPE 110.1 THO. -2
R/OL
_.. 875
?�I
6.1021GP�
46,'SEWER GRAVEL
0L SP
lzsoq sTE.ali 470 I
TANK NEW
PROFILE
-2.0
m ga
Ski
- NO GROUND WATER
ENCOUNTERED
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 3(450 gpd)
TANK SIZE: 1250g S.T.E.P
PERC RATE: <1.5 MPI
SOIL RATING: 1.2 GPD/SF ABBREVIATIONS
AREA ROD: 375 SF w w WATER LINE / TH TEST HOLE
SYS. TYPE: DEEP TRENCH 4.O'E0 WELL RADIUS (P) PROPOSED
MIN LENGTH: 47.0 LF
(E) EXISTING
USED: — ss ss — NEW SEPTIC CO CLEAN OUT NO.
47LFx2.0'Wx4.0' E.D., 8.0' TD MT MONITOR TUBE NO.
TOTAL AREA: 376 SF TYYPC TYPICAL
NOTES: PL'11`!1\ONE ENG SVC, LLC y` • Date
6/2016
RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 �P '•• Scale 7/27/2
PHONE (907) 272-8218 FAX (907) 272-8211
*• ••* NTS
...... :. P.LD. NO
JUNIPER VALLEY, BLOCK 4, LOT 12 050-751-47
SPINELL HOMES INC. PE
DRAWN NJC 81'9 RMIT No.
3945 MARIAH DR. SW070263
SITE PLAN EAGLE RIVER, AK 99577 Sheet
2 OF
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SW070263
Legal Description: JUNIPER VALLEY BLK 4 LT 2
Design Engineer: 0070 ARC TERRA ENGINEERING & SU
Owner Name: JEFF & SUSAN LAKOMSKI
Owner Address: 1600 S EADS STREET #704S
ARLINGTON , VA 22202-2907
Date Issued: Sep 26, 2007
Expiration Date: Sep 25, 2008
Parcel ID: 050-75147
Site Address:
Lot Size: 155074 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
❑ Water Storage
a� pro
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Date: q y-7
Issued By: �n Date: L"
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWERMELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. n50 1S1 _ 41
Pro erty owners) 14
r j fcu4'1 b
wsk'l
phone
p
Mailing address 1 X01iri3 NIG,k{ 91 ur-F Zip Code Q4S-7-1
Site address
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
Lot Size / g- , 01 qSq. Ft.
THIS APPLICATION IS FOR (® all that apply):
Absorption Field
IBJ
Septic Tank
CR
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
IM -1
Number of Bedrooms
Code 94 Y - 7i
1-2-
Number
Z
3
THIS APPLICATION IS AN:
Initial
❑
Upgrade
❑
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of
authorized agent)
PermitlRush Fees:;4/zso. Waiver Fees: 40aE
Dateof Payment: 2ya7 Date of Payment: 40O p 3 3 ecei t Number. Q 3 '3
Receipt Number. p
(Rev. 11/05)
-'a ....;.0'
September 24, 2007
ACTERRA
ENGINEERING AND SURVEYING, INC.
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Septic Permit—juniper Valley, Block 4, Lot 2
Gentlemen:
The owner has requested we proceed forward to obtain a septic permit for the
proposed 3 -bedroom residence on the subject lot. Per our discussion with you
previously, we are requesting a 35' wastewater system to slopes greater than 25
percent waiver at this time. The requested separation reduction requested with
this waiver is based on the criteria outlined in the MOA Memorandum of April
7, 2004.
On September 12, 2007 two testholes were performed for the proposed system.
The results of these tests are attached. With exception of the terraced portions of
this lot with slopes of 8-127o, the general slope of this lot is from east to west at a
grade of approximately 35-5070.
We have designed our system utilizing the recent testholes that were excavated
for the proposed 3 -bedroom house. We propose to install one 2' wide 47' long
trench. Water was not encountered during the excavation or during monitoring.
The lot will be served by an existing, individual well, located on the southern
portion of the lot.
There are no public or private wells within 200' of our proposed system location
except as noted. There is no surface water within 100' of the proposed system,
except as noted and there are no known curtain drains within 50'.
RE: juniper Valley 134, L2
September 24, 2007
Page 2 of 2
We do not expect there to be any adverse effect on adjacent jots by the
development of this system. If you have any questions, please contact me at 868-
3792/FAX 868-3793.
Respectfully submitted,
ArcTerra Engineering & Surveying, Inc.
Kenneth M. uffus, P.E
Attachments: On -Site Well and Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/ Percolation Tests
Owner/ Contractor Specs
20141 VrARIIIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793
WASTEWATER DISPOSAL SYSTEM DETAILS / SITE PLAN
JUNIPER VALLEY SUBDIVISION BLOCK 4. LOT 2 050-751-47
BL 0 C K 4
LOT 2
PACE 2 OF 3
.. KENNET....cl . ./
�1
z- e epi
\\\\\\ A'bfE3310N�•'
a..�u.e., r cconr _ RW M 1•eel\JuniDH
TRENCH PLAN
ABBREVIATIONS_
BOH . BOTTOM OF HOLE
CO • CLEANOUT
FCD • FOUNDATION CLEANOUT
LF . LINEAR FOOT
MT . MONITORING TUBE
MH . MANHOLE
PREPARED FOR:
JEFF & SUSAN LAKOMSKI
10443 HIGH BLUFF DRIVE
EAGLE RIVER. AK 99577
786-3566
FIELD BOOKS
"SECTION".
ro��
9wwmr.
, 4
DRAY .
SEE PRIMARY SYSTEM
/
q,_
PROPOSED
Asanr.
SHEET 3 of 3. 9 4YL . 2'W 4'D
TRENCH.
I
^O
vS
BRED
RESERVE
SYSTE
PRESSURIZED
TOTAL DEPTH 10' MAX.
FROM ORIGINAL GRADE
I
ACRD fU:
HOUSE
_
/
JOB "'
CJI
10' \
1 56 LF 1-1/4"
I
/
PVC PRESSURIZED
'
MT
�
E%ELLG
I
�
�
THo7-2
�
c /
1\ TH0077-1
Iiv//IIT1\� "� JQ /
CO
\
0 fC0
MH
lF
p PIPE
PIPE 4..
SOLI P SOLID PIPE
CO
1250 GAL S.T.E..
\
.I
\
GRAVEL D/M
Ap'
P
�
MONUMENT
Trn
K
JUNIPER
VALLEY
SUBO.
PACE 2 OF 3
.. KENNET....cl . ./
�1
z- e epi
\\\\\\ A'bfE3310N�•'
a..�u.e., r cconr _ RW M 1•eel\JuniDH
TRENCH PLAN
ABBREVIATIONS_
BOH . BOTTOM OF HOLE
CO • CLEANOUT
FCD • FOUNDATION CLEANOUT
LF . LINEAR FOOT
MT . MONITORING TUBE
MH . MANHOLE
PREPARED FOR:
JEFF & SUSAN LAKOMSKI
10443 HIGH BLUFF DRIVE
EAGLE RIVER. AK 99577
786-3566
FIELD BOOKS
COw TEM.
9wwmr.
, 4
DRAY .
CI
sTAww:
NA
04ECKCD: KMO
Asanr.
NA
DATE:
09/24
m rat:
pno:
SE704
ACRD fU:
JOB "'
06-113
34. L2\06-1130—S9D1iC D9v9n.o.9
1
GRAPHIC SCALE
0 20 40
SCALE: 1 40'
'ii.J3��11�11
4� 4Np S� een
i AX 99111.11"1
LOT 1
WASTEWATER DISPOSAL SYSTEM OVERALL PLAN Permit No.
JUNIPER VALLEY SUBDIVISION BLOCK 4, LOT 2 Swoxxxx
JUNIPER VALLEY SUBO.
LOT 3
— MARIAN DRIVE—9
— —
f—
NO PUBLIC MTNIN 2005 OF
PROPOSED SYSTEM. NO PRIVATE
WELLS M IN 0' PROPOSED
�. SYSTEM EXCEPT
20 20 %CEPT AS NOTED.
GRAPHIC SCALE
p 50 100
SCALE: 1 100'
PAGE 1 OF 3
% OF AL4
.4 9 T.H*1
�E LSQFS DESIGN DETAILS
3 BDRM X 150 CPD- 450 CPD
450 CPD/1.2 GPD PER SO. FT. (1.5 MIN/IN.)- 375 SO. FT
375 SO. FT/2 x 4 D (Rock) - 47 FT. TRENCH
USE 1 TRENCH- 47 (L) X 2' (W) X 4' (D) - 10' O.C.
Total depth of system is 10' mox. from original grade.
471 / 30 HOLES - 1.6' SPACING W/ 3/16* HOLES
Holes faced down or with manufactured caps & capped ends.
NOTES.
1. INSTALL 1250 GALLON S.T.E.P. do INSULATE IF < 4' COVER.
2. INSULATE TRENCH WITH 2" HD BURIAL FOAM IF < 3' COVER.
3. CONTRACTOR WILL ENSURE MAXIMUM 2% SLOPE INTO SEPTIC TANK.
4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS. SEPTICS. LOT LINES. FOUNDATIONS AND ALL OTHER SETBACKS.
PREPARED FOR:
JEFF do SUSAN LAKOMSKI
10443 HIGH BLUFF DRIVE
EAGLE RIVER. AK 99577
786-3566
........ - . ......
TKENN'011DU V '
CE- 16 4• �
�
..
1 .1 �z�4 . T� /
%FESS1011" /
`%!
FIELD BOOKS
casuTEO,
wuwmr. 0703/48
MAen: I
srMlwc NA
O"Emm: KMO
Aseuar. fJq
DATE' 09/24/
D.c. ME!
a°° SE704
AM nL,
JOB Nu' 06-113
\WELL h SEPTIC — riled By Lego)\Juniper Volley\84. L2\08-1130—Septic Dsefgn.dwq
s
llii.']��11�11
�Bti �ii�/�g011
L
74 � srfn-sTj6
MIZ
lii]��11t1
ARXERRA NC.
ENGUNEERING AND
l\�!3JI1/��
n„p se-
t
SOILS PERCOLATION TEST
Performed for. Jeff & Susan Lakomski Date Performed: 9 1 07
Project: Iutiler Valley loch d i n(2 TEST HOLE p T1107-1
Depth
(Feet) SEE ATTACHED SITE PLAN
..^t I FOR HOLE LOCATION
Drg/OL
GP/SP—trace of silt
SU — damp
B.O.} I.
ROLE PRESOAKED
PRIOR TO TEST
Was Ground water encountered? NO
Depth to water after monitoring? DRY
What depth? NA
Date? 9/19/07
Reading
Datc
Gross
Time
Net
Time
Depth to
Water
Net
Dro
1
9/19/07
10)
T'
2
1:10
10 min
DryT'
3
*
1:11
7"
4
1:21
10 min
Dry
7"
5
*
1:22
7"
6
1:32
10 min
1/16"
6 15/16"
7
+
1:33
T'
g
1:43
10 min
2/16"
6 14/16"
9
+
1:44
T.
-
10
1:54
10 min
2/16"
6 14116"
11
*
1:55
7"
12
2:05
10 min
2/16"
6 14/16"
+
Water
Added
Percolation Ratc j.4 (minfin) Pere Ilole Diameter 6"
Test Run Betwcen 6 feet and 7 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
�sTERM
ARGlERRA
iY1r ENGINEERING AND SURVEYING, INC.
i Oft
t t fnrrarN
SOILS PERCOLATION TEST
Performed for. ,Leff & Susan Lakomski Date Performed:09 1 07
Project: IuniDer Valley Block a j,ot2 TFST HOLE # T1107-2
Depth SEE ATTACHED SITE PLAN
(Feet)
r^ l FOR HOLE LOCATION
Drg/OL
GP/SP— trace of silt
SNI—damp
B.O.H.
17-
18-
19 -
HOLE PRESOAKED
20- PRIOR TO TEST
was Groundwater encountered? NO
Depth to water after monitoring? DRY
what depth? NA
Date? 9/19/07
Reading
Datc
Gross
Time
Net
Time
Depth to
Water
Net
—Drop
1
9/19/07
1:00
7
2
1:10
10 min
3/16"
6 13/16"
3
•
1:11
T'
4
1:21
10 min
5/16"
6 11/16"
5
+
1:22
7"
6
1:32
10 min
6/16"
610/16"
7
•
1:33
T'
-
8
1:43
10 min
5/16"
6 11/16"
9
Y
1:44
7
10
1:54
10 min
5/16"
611/16"
11
•
1:55
7
12
2:05
10 min
6/16"
6 10/16"
*
Water
Added
Percolation Rate 1.5 (min/in) Perc Hole Diameter 6"
Test Run Between 6 feet and 7 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
i
ARCIERRA
ENGINEERING AND SURVEYING, INC.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS
LEGAL DESCRIPTION: JUNIPER VALLEY 134, L2
GENERAL:
1. The scope of this project includes the installation of a septic tank and/or
drainfield to serve a single-family residence on the referenced property as
delineated on the attached Municipality of Anchorage (MOA) permit and site
plan. Construction shall be in accordance with the approved site plan and
design drawings; MOA permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
2. ArcTerra Engineering & Surveying, Inc. (ArcTerra) assumes no responsibility of
the accuracy of the as -built survey provided by the owner or owner's
representative.
3. The owner or contractor is responsible to notify the engineer of any discrepancies
noted on the design plans or drawings prior to commencing work. These
discrepancies could be, but not limited to, possible encroachments, surface water,
varying soils, unplatted easements, types or use of dwellings on or adjacent to
property, nearby public wells, etc.
4. The contractor shall be responsible for locating any necessary underground
utilities, easements, property lines and surface water. The owner and/or
contractor shall ensure, if deemed appropriate, that a registered land surveyor
prior to construction flags all setbacks. The contractor shall be responsible for
verifying all pertinent separation distances and component layout.
5. Unless specifically agreed otherwise, the property owner shall be responsible for
final grading areas subsequently depressed from soil settling. On all leachfield
mound systems, the property owner shall be responsible for ensuring a
satisfactory vegetation growth over the mounded area.
6. The MOA Development Services Department On -Site Water & Wastewater
Program must certify contractors installing wastewater disposal systems.
Owners installing their own systems must also receive prior approval from said
MOA Department.
SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION:
1. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded with proper material and compacting
to prevent damaging, settling or shifting of the tank.
3. All standpipes on the septic tank shall extend a minimum of 12 inches above the
final grade.
4. Septic tanks installed with less than 4 foot of cover shall be insulated. The
contractor will ensure that the fill over the tank does not exceed the burial depth
rating.
5. A foundation cleanout shall be installed one to four feet from the building
foundation. In the line between the tank and the leachfield there shall be two
JUNIPER VALLEY B4, L2
September 24, 2007
Page 2 of 3
adjacent cleanouts (unless an effluent pumping system exists within the septic
tank). These cleanouts shall be located on undisturbed soil not more than 10 feet
from the tank. The second cleanout, in line, shall be to clean toward the septic
tank.
6. Final grading over the septic tank shall be such that a positive slope exists away
from the septic tank.
7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe
besides the tank extending to the bottom of the tank to above grade to monitor
ground water.
8. All tanks shall be anchored when there is not enough adequate soil cover to resist
buoyancy forces in high -groundwater areas.
9. All holding tanks and lift stations shall have an audible and visual alarm inside
the residence.
10. All lift stations shall be wired in compliance with the Uniform Electrical Code
and all MOA guidelines.
11. The contractor shall remove the old tank, or abandon it in compliance with the
Uniform Plumbing Code. The contractor is solely responsible for the
abandonment procedure.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the sidewalls of the
excavaction become smeared, they must be raked or scratched (roughed -up)
before gravel (sewer rock) placement.
2. Once the sewer rock is installed, the distribution pipe is installed level with the
perforations facing downward. Gravel is then to be placed over the distribution
pipe to provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native soil
backfill. Ensure the silt barrier covers the entire gravel surface before placing
backfill.
4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the
locations shown on the design, and extend a minimum of 12 inches above final
grade. The portion of the monitoring tube extending through the gravel shall be
perforated from the bottom of the trench to the invert of the distribution pipe.
This is equivalent to the effective depth of the gravel as noted on the design.
5. Backfill over the final gravel layer must not be less than twenty-four inches.
Insulation must be installed when the backfill depth is less than thirty-six (36)
inches. The finish grade over the trench must be mounded to prevent the
formation of a depression after settling.
6. All advanced technology waste water disposal systems (Advantex, Biocycle,
Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained
and monitored per manufacturer's specifications and MOA requirements.
MINIMUM MATERIAL SPECIFICATIONS:
1. A MOA approved septic tank manufacturer must construct any septic tank
proposed for installation.
2. The following pipe materials are MOA approved for use in septic system
installations:
Type of Pip Perforate s6d
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793
JUNIPER VALLEY B4, L2
September 24, 2007
Page 3 of 3
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder,
Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be
installed between the final leachfield gravel layer and the native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than
37o passing the #200 sieve. If deemed necessary, a sieve analysis should be
performed.
7. When sand is being used as a filter material, its gradation specification must
conform to current MOA or ADEC requirements.
INSPECTIONS:
Typically there will be three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
1. The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
2. The second inspection must be conducted after the placement of the sewer rock,
distribution lines, standpipes, and cleanouts, but before the placement of the silt
barrier, insulation, or any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required, especially with the
installation of multiple trenches, sand filters, pressurized distribution systems, etc. The
inspecting engineer is to be contacted at least 24 hours prior to the start of construction.
If necessary, a pre -construction meeting will take place on-site. The inspecting engineer
will not coordinate, direct or control in any way the contractor's activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and attached plans and in accordance with the attached MOA permit. All
materials, components, and construction practices shall comply with the MOA's and the
State of Alaska's latest ordinances, regulations, or policies regarding wells and septic
systems. The failure of the inspecting engineer to notice a material or construction non-
compliance does not relieve the contractor of his/her responsibility to correct such
deficiency. There will be no contractual arrangement existing between the contractor
and ArcTerra. ArcTerra shall be the owner's representative and will inspect the work as
stated above to document the contractor's activities. Final acceptance of the contractor's
work rests with the owner and the MOA.
ArcTerra shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these construction documents.
ArcTerra's inspecting engineer will not be responsible for the construction means,
methods, and techniques, sequence, procedures or the safety precautions incident to this
project.
BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER
WASTEWATER SYSTEM (S), THE PROPERTY OWNER, AND/OR WELL DRILLER ACKNOWLEDGE HAVING READ AND ACCEPTED HESE
SPECIFICATIONS.
20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868.3791 • FAX (907) 868-3793
i
N
JN
Q 00
IN
Q W
0
L.
EGiION
61n. !
n
W :
a
O
O
Q
y
J
C6
�
y
a
U
J
0
a
J
J
�
_
!
Q
S
U
p
v>a
W
>
C
tJ
li
a
A 1
01
N
O
MUNIGIPA�I"(Y 01
t
W
m
PK
W
W
(7
L.
EGiION
61n. !
W :
=
C6
y
J
0
a
z
w
ud
Z
3
n
u
p
v>a
a
G
C
B
�CI
A 1
ren
A 67 _
A
MUNIGIPA�I"(Y 01
t
PK
EN�IRO;;�A�,11A�
�.J
�•
l,,
r��E�ts. �
�' �YIF
st
i.t i
•i:
H.
:.t
A
z
-
W
a
w
p
�
vz VHi
W
3
A
w d
L.
EGiION
61n. !
t
�nll
%Z
J
Ili
z
p
a
p
w
z
i
rA
=
0
tt
tr :
st
i.t i
H.
w
O
O
O
0
0
0
0
0
0
o
0
F
[�
E'
[-
f'•
Ew
H
F
�
H
[q
o
0
A
0
o
0
p
p
0
w
w
w
w
w
w
w
w
w
w
w
w
w
cFt
w
w
w
O
O
O
o
0
0
0
p
0
0
0
x
x
x
x
rx
x
x
x
9
a
W
w
w
w
w
w
w
w
w
w
w
w
t
�nll
%Z
J
Ili
z
p
a
p
w
z
i
rA
o
0
A
0
o
0
p
p
0
0
0
0
w
w
cFt
w
w
w
U.
U.
z
w
o
0
0
0
0
0
0
0
0
0
0
0
p
w
w
w
w
w
w
w
w
w
A
w
w
c°,
z
t
�nll
%Z
J
Ili
z
p
a
p
w
z
i
rA
Parcell.D.
050-751-47
6/V �- v
e1Z
Municipality of AnchoraOn-Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems
1. GENERAL INFORMATION
Expiration Date: I -
Complete le*.description Juniper Valley, Block 4, Lot 2
Location (site address) 3945 Mariah Dr.
ET
Current Property owner(s) Spinell Homes Inc. Day phone
Mailing address 1900 W Northern Lights Blvd #200 Anchorage, AK 99517
Real Estate Agent Day phone
2. TYPE OF DWELLING:
Ix Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
Individual
Il
Individual Water Storage
❑
Holding Tank
I]
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request
Received by: A /t-kf j / Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $li�•c(r�j Waiver Fee $
2
Date of Payment 7 Date of Payment
Receipt Number 07LO6 Receipt Number
COSA# OSC/6i3oJ' Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that n y investigation, based on procedures outlined
in the Certificate of On -Site. Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater
disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply
and/or. wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at
the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordancTwith MoA COSA
guidelines and regulations. The reported results describe the performance of the system under the conditions encounteredat t. the test,
and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend or tloogl foil
condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. Thes n88i¢ ns
are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee fu ure
performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warrant/
for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed
above.
Name of Firm Pannone Engineering Services LLC
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
6. DSD SIGNATURE
System #1 Approved for LZ bedrooms
System #2 Approved for bedrooms
Disapproved
Phone (907) 272-8218
Date 6/18/2016
• 16ven . 06r riorie
Conditional approval for bedrooms, with the following stipulations:
By rA Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet ° c
If more than 1 septic system is on the lot:
COSA Checklist #? of
Structure served by this system
Certificate of On-Site Systems
Approval Checklist
Legal Description: Juniper.Valley, Block 4, Lot
Parcel ID: 050-751 -47
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Well Log (Y/N) Y
Date completed 6/17/1983 Sanitary seal (Y/N) Y
Wires properly protected (YIN) Y
Total depth 520 ft. Cased to 254 ft.
Casing height (above ground) � 2+ in.
FROM WELL LOG
` AT INSPECTION
Date of test 6/17/1983
6/6/2016
Static water level 260 ft.
214 ft.
Well production 16.7 g.p.m.
5.0+ 9-
p.m-WATER SAMPLE RESULTS:
Coliform Neg colonies/100 mL Nitrate ND mg/L
Arsenic -ND ug/L Date of sample: Z/6/2016
Collected by: PES
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material S.T.E.P./Steel
Date installed 10/3/2007
Tank size 1,250 gal. Number of Compartments 2—.
Cleanouts (YIN) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N)
N High water alarm (Y/N) N
Date of pumping New* Pumper N/A
C. ABSORPTION FIELD DATA
10/3/2097 z z
Date installed - Soil rating (g.p.d./ft or ft /bdrm}
1.2 GPD/SF Deep Trench
System type
Length 47 ft_. Width- 2
ft. Gravel below pipe A ft.
Total depth 10 ft. Eff. absorption area 376 ftz Monitoring tube YDepression over. field N
Date of adequacy test New Results (Pass/Fail) PASS For 'bedrooms
Fluid depth in absorption field before test New in. Water added New gal. New depth New in.
Elapsed Time: New' min. Final fluid depth New in.
Absorption rate >= 450+ g p d
Any rejuvenation treatment (past 12' mo.) (YIN & type) No
If yes, give date
D. LIFT STATION
Date installed 10/3/2007 Size in gallons 1;250
"Pump on" level at 42 ' in. "Pump off level at 40 in.
Datum Bottom of Tank Cycles tested pqe�*
Manhole/Access (Y/N) X
High water alarm'level at 45 in.
Meets alarm & circuit requirements? Yes
E. - SEPARATION DISTANCES
-WELL ON LOT TO:
Septic tank/lift station on lot 100+ On adjacent lots 100+
Absorption field on lot 100+ On adjacent lots 1bb+
Public sewer main 75+. Public sewer manhole/cleanout 100+
Sewer/septic service line 25+ Holding tank 100+
Animal containment areas 50+ Manure/animal excrete storage areas 1 OQ+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5+ Property line 5+ Absorption field +
Water main 10+ Water service line 10+ Surface water 100+
Wells on adjacent lots 100+ -
ABSORPTION FIELD ON 40T TO:
Property line 10+ Building foundation 10+ Water main -
r'
Water Sevice line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+
Curtain drain 50+ Wells on adjacent lots 100+
F. COMMENTS
Building was just built on the property. 5eptio'has never been in use. .
*At date of well flow test tank was empty. **Slope waiver on file
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and.
review of Municipal records that the above systems ale in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven PanTrone
Date 6/18/2016
ti
COSA canary sheet 2.6-IS.doc
PLAT NO. 82--49
JUNIPER VALLEY SUBDIVISION
LOT 2 g BLOCK 4
AS -BU I LT
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
GASTALD I LAND
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
I
SURVEYING, LLC
JEFF A. GASTALDI, R.LS.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
2000 E DOWUNG RD.. SUITE" 8
COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 89507
APPS ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-5454
UNDER NO CIRCUMSTANCES: SHOULD ANY DATA
GRID
DATE
HEREON BE USED FOR CONSTRUCTION OR FOR
3/30/2016
ESTABUSHING BOUNDARY OR FENCE LINES.
SE705
ANCHORAGE RECORDING DISTRICT, ALASKA
F.B.
JOB NO.
JVS24
NOTE: NO CORNERS SET THIS DATE
1,11-601
BUILDING DETAIL
SCALE: 1 "=20'
.P F:>•OF•••q� 4S
a ••f.♦
.....
Jeffery A. Gaelaldl l g 0
LS -6091 1 O
�O7eaalona�l-°c �'�