Loading...
HomeMy WebLinkAboutJUNIPER VALLEY BLK 4 LT 2Juniper Valley Block 4 Lot 2 #050-751-47 �sr« & COLE oecoaos 4P.O. Box 670269, g RLL VA�IWATER WELLS www.suilivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW 070263 Date of Issue 9-26-07 Parcel Identification Number: 050-751-47 ILegal Description Juniper Valley Lot 2 Block 4 Pump Installation Date: 8-4-15 Pump Intake Depth Below Top of Well Casing: 480 Pump manufacturer's Name: Grundfos Pump Model: SSQE35-450 Pump Size: 1.5 Pitless Adapter Burial Depth: N/A Pitless Adapter Installer: N/A Disinfected Upon Completion? ® yes ❑ no Method of Disinfection: Chlorine 50 PPM Comments: Pump Installers Name: Sullivan Water Wells Property Owner Name & Address Spinell Homes 1900 W. Northern Lights Blvd 6200 Anchorage, AK 99517 feet r, feet Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Municipality of Anchorage V MAYO 4 Lu, Community Development Department Page of On -Site Water and Wastewater Program 4700 Elmore St. ° P.O. Box 196650 Anchorage, AK 99519-6650 ° http://www.muni.org/onsite ° (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SWO70263 PID Number: 050-751-47 ® New El Upgrade Name: JEFF & SUSAN LAKOMSKI ABSORPTION FIELD ®Deep Trench El Shallow Trench El Bed ❑ Mound Address PO BOX 771445, EAGLE RIVER, AK 99577 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2 GP D/SF 10 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6 Ft. Gravel depth beneath pipe 4 Ft. Subdivision Block Lot JUNIPER VALLEY 4 2 Fill added above original grade unk Ft. Gravel length 47 Ft. Township Range Section Gravel width 2Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 375 + Ft 1 NAFt, Well TANK ❑ Septic 0 S.T.E.P. ❑ Holding ❑ Other 100'+ 100'+ NA NA 25'+ Manufacturer Anchorage Tank Capacity 1250G,1. Surface Water 100'+ 100'+ NA NA NA Material Steel Number of compartments 2 Lot Line 5'+ 10'+ NA NA FoundationLIFT STATION 5'+ 10'+ NA NA Manufacturer Capacity Curtain Drain NA *50'+ NA NA Anchorage Tank 1250 Gal. Remarks *None known. Existing well. No house built. Pump on level at in. Pump off level at in. I High water alarm at in. No components installed in STEP. System built per design with final inspection, elevations & as -built Pump make and model Electrical Inspections performed by pending owner notice to proceed. Installer PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield R.P.C. Drainfield D3034 COIMT D3034 Inspector ArcTerra Consulting, Inc. BENCH MARK (Assumed elevation) --ft Inspdates: 1 ° 10/2/2007 d 10/03/2007 Location and description 2 3'd Pending 4'" COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp / Y' _ r '"� OF �:44 Conditional Approval: .':.��'Z�''' Date ��'r� ,rr-'P��,a••°°°�,��� -� _� F[3147N`. •�� °ao�n`3 it i U, aenoaas0y0 000 0o xo Y F UI ell V,&V .,w. eli a j �..e. ° .0, vvv® .0,O Kang , rv{. Uui 4� CE 7116 le 'A �� 9F� `6 e(i Date ApproCE p a`F�"" P�' AO 11? Inspection Report_1-1-12.doc Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.orglonsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SW070263 PID Number: 050-751-47 0 New ❑ Upgrade Name: ABSORPTION FIELD Spinell Homes ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 1900 West Northern Lights Blvd ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 GPD/SF 8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4 Ft. Gravel depth beneath pipe - 4Ft. Subdivision Block Lot Juniper Valley 4 2 Fill added above original grade - 0 FL Gravel length 47 Ft. Township Range Section Gravel width Ft Fc Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption - Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 376 Ft= 1 NIA Ft. Well 111.8 149.0 118 N/A 25+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,000Gal. Surface water 100+ 100+ N/A N/A Material Steel Number of compartments. 2 Lot Line 83 100+ 83 NIA NA Foundation 122 164 N/A N/A LIFT STATION Manufacturer Orenco Capacity 250Gal. Curtain Drain 50+ 50+ NIA NIA Pump on level at Pump off level at Her waTer�larm at Remarks * See Inspection report by Arc Terra. PES 40 in. 36 in. } ��" 5in. performed a record survey to close out permit for Owner. This report IS for what PES found. For all other Pump make and model P2005-1 Electrical Inspections perform by twikVA,0l�1ti info see Arcterra's Report PIPE MATERIAL Hou eto Tankto" drainf Installer Unknown Drainfel O/MT 3034 Inspector PES BENCH MARK (Assumed elevation) 100ft Inspection i 1s 6/6/2016 6/28/2016 Location and description dates: 2�a Garage FF sb 4,n COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp oT�\NN, +s O� q�� Conditional Approval: Date !4�, ••" • ��ey0 �,:S W.�n' A r - ed Date InspectidLi F3cffSbrt_1-1-12.doc Municipality Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program �lrenr c , Department **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV161085 COSA#: OSC161305 Permit#: SW070263 PID#: 050-751-47 Legal Description: Juniper Valley Block 4 Lot 2 Engineer: Pannone Engineering Services Applicant: Spinell Homes The following separation distance waivers are approved. 1. 29 feet between the drainfield and a 25 percent or greater slope. This waiver approval applies to the existing drainfield only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. X Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: / X Waiver is not Granted: Date: �o ( Approved by: a e of Reviewer ................................................ ............................. Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panenaak.com July 26, 2016 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. 0. Box 196650 Anchorage, Alaska 99519 Subject: Juniper Valley, Block 4, Lot 2 Septic System to Steep Slope Waiver Request Ladies and Gentlemen: I am writing to �X= est a sfeparat�n dis nce waiver between the proposed septic system and a slope of greater than 25feet (29'). �� n ? h Q The soils in this area ar ypicall rologic Soils Group A which contains organics underlain by poorly graded gravel and s Record information shows a percolation test on the proposed lot and found a percolation rate of one point five minutes per inch (1.5 mpi). The soil composition and percolation rate confirms the soil classification of HSG A. Due to the nature of and drainage capacity of the soils found in the area (HSG A) the designed infiltration line of 45% for septic system installation on steep slopes should be used instead of the assumed/worst case soil classification infiltration line of 25%. The slopes and soil types enable installation of any conventional system without the system effluent "daylighting" further down the slope of the hill provided bury depth requirements are met. Granting this waiver will not pose a threat to the safety of this lot or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 Please contact me if you have any comments or concerns. Sincerely, Steven R. Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: -Site Plan Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 �o'la ALLoy, TRENCH x 4 E x 8'TD) Yn/ 'Al. � I I M \�� 1,250 al STEP TANK TRUE NORTH SCALE : t"= 50'I \LS TI 1 49.0 LOT 2 V 111.8 \ \ DRIVEWAY C1 \ \ WELL E \ NOl \ A \ I V B 3BR / \ \ SFD / \ \ Al NOTES: RECORD DRAWING DRAWN I NJC SITE PLAN PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 JUNIPER VALLEY, BLOCK 4, LOT 12 SPINELL HOMES INC. 3945 MARIAN DR. EAGLE RIVER, AK 99577 / {.� A B FC 20.9 6.1 C 1 87.9 86.0 T1 123.8 1225 LS 1317 129.9 M1 164.3 171.3 M2 206.1 212,4 NOTES: RECORD DRAWING DRAWN I NJC SITE PLAN PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 JUNIPER VALLEY, BLOCK 4, LOT 12 SPINELL HOMES INC. 3945 MARIAN DR. EAGLE RIVER, AK 99577 / {.� 7/27/2016 Scale • P.I.D. NO Ali. re 050_-_751-47 _ h OAA CE 8149 .• PERMIT N0. SW070263 1 OF 2 SPECIAL PROVISIONS TO SPECIFICATIONS NGINEERING AND SURVEYING DESIGNED AND INSPECTED STYSTEM. PES IS VENTING WHAT WAS FOUND DURING SITE INVESTIGATIONS. SEWER GRAVEL 6" ABOVE PIPE INVERT 4" m PERF PIPE NO% FILTER FAERIC�j I c SRPt,ON 25 `N,1lTNUR uPs NEI I SEWER sR E Ns � GRAVEL 4pGo 5 ANeVL ' _ Op, —5c] o FILTER FABRIC m o_ -p o o o � SEER GRAVd o" ABOVE PIPE INV � a 2 r s / z x1.125' m DRAINPIPE 110.1 THO. -2 R/OL _.. 875 ?�I 6.1021GP� 46,'SEWER GRAVEL 0L SP lzsoq sTE.ali 470 I TANK NEW PROFILE -2.0 m ga Ski - NO GROUND WATER ENCOUNTERED DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 3(450 gpd) TANK SIZE: 1250g S.T.E.P PERC RATE: <1.5 MPI SOIL RATING: 1.2 GPD/SF ABBREVIATIONS AREA ROD: 375 SF w w WATER LINE / TH TEST HOLE SYS. TYPE: DEEP TRENCH 4.O'E0 WELL RADIUS (P) PROPOSED MIN LENGTH: 47.0 LF (E) EXISTING USED: — ss ss — NEW SEPTIC CO CLEAN OUT NO. 47LFx2.0'Wx4.0' E.D., 8.0' TD MT MONITOR TUBE NO. TOTAL AREA: 376 SF TYYPC TYPICAL NOTES: PL'11`!1\ONE ENG SVC, LLC y` • Date 6/2016 RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 �P '•• Scale 7/27/2 PHONE (907) 272-8218 FAX (907) 272-8211 *• ••* NTS ...... :. P.LD. NO JUNIPER VALLEY, BLOCK 4, LOT 12 050-751-47 SPINELL HOMES INC. PE DRAWN NJC 81'9 RMIT No. 3945 MARIAH DR. SW070263 SITE PLAN EAGLE RIVER, AK 99577 Sheet 2 OF MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW070263 Legal Description: JUNIPER VALLEY BLK 4 LT 2 Design Engineer: 0070 ARC TERRA ENGINEERING & SU Owner Name: JEFF & SUSAN LAKOMSKI Owner Address: 1600 S EADS STREET #704S ARLINGTON , VA 22202-2907 Date Issued: Sep 26, 2007 Expiration Date: Sep 25, 2008 Parcel ID: 050-75147 Site Address: Lot Size: 155074 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy All construction must be in accordance with: 1. The attached approved design. ❑ Water Storage a� pro 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: q y-7 Issued By: �n Date: L" Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. n50 1S1 _ 41 Pro erty owners) 14 r j fcu4'1 b wsk'l phone p Mailing address 1 X01iri3 NIG,k{ 91 ur-F Zip Code Q4S-7-1 Site address Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size / g- , 01 qSq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field IBJ Septic Tank CR Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage IM -1 Number of Bedrooms Code 94 Y - 7i 1-2- Number Z 3 THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of authorized agent) PermitlRush Fees:;4/zso. Waiver Fees: 40aE Dateof Payment: 2ya7 Date of Payment: 40O p 3 3 ecei t Number. Q 3 '3 Receipt Number. p (Rev. 11/05) -'a ....;.0' September 24, 2007 ACTERRA ENGINEERING AND SURVEYING, INC. Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Permit—juniper Valley, Block 4, Lot 2 Gentlemen: The owner has requested we proceed forward to obtain a septic permit for the proposed 3 -bedroom residence on the subject lot. Per our discussion with you previously, we are requesting a 35' wastewater system to slopes greater than 25 percent waiver at this time. The requested separation reduction requested with this waiver is based on the criteria outlined in the MOA Memorandum of April 7, 2004. On September 12, 2007 two testholes were performed for the proposed system. The results of these tests are attached. With exception of the terraced portions of this lot with slopes of 8-127o, the general slope of this lot is from east to west at a grade of approximately 35-5070. We have designed our system utilizing the recent testholes that were excavated for the proposed 3 -bedroom house. We propose to install one 2' wide 47' long trench. Water was not encountered during the excavation or during monitoring. The lot will be served by an existing, individual well, located on the southern portion of the lot. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system, except as noted and there are no known curtain drains within 50'. RE: juniper Valley 134, L2 September 24, 2007 Page 2 of 2 We do not expect there to be any adverse effect on adjacent jots by the development of this system. If you have any questions, please contact me at 868- 3792/FAX 868-3793. Respectfully submitted, ArcTerra Engineering & Surveying, Inc. Kenneth M. uffus, P.E Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/ Percolation Tests Owner/ Contractor Specs 20141 VrARIIIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793 WASTEWATER DISPOSAL SYSTEM DETAILS / SITE PLAN JUNIPER VALLEY SUBDIVISION BLOCK 4. LOT 2 050-751-47 BL 0 C K 4 LOT 2 PACE 2 OF 3 .. KENNET....cl . ./ �1 z- e epi \\\\\\ A'bfE3310N�•' a..�u.e., r cconr _ RW M 1•eel\JuniDH TRENCH PLAN ABBREVIATIONS_ BOH . BOTTOM OF HOLE CO • CLEANOUT FCD • FOUNDATION CLEANOUT LF . LINEAR FOOT MT . MONITORING TUBE MH . MANHOLE PREPARED FOR: JEFF & SUSAN LAKOMSKI 10443 HIGH BLUFF DRIVE EAGLE RIVER. AK 99577 786-3566 FIELD BOOKS "SECTION". ro�� 9wwmr. , 4 DRAY . SEE PRIMARY SYSTEM / q,_ PROPOSED Asanr. SHEET 3 of 3. 9 4YL . 2'W 4'D TRENCH. I ^O vS BRED RESERVE SYSTE PRESSURIZED TOTAL DEPTH 10' MAX. FROM ORIGINAL GRADE I ACRD fU: HOUSE _ / JOB "' CJI 10' \ 1 56 LF 1-1/4" I / PVC PRESSURIZED ' MT � E%ELLG I � � THo7-2 � c / 1\ TH0077-1 Iiv//IIT1\� "� JQ / CO \ 0 fC0 MH lF p PIPE PIPE 4.. SOLI P SOLID PIPE CO 1250 GAL S.T.E.. \ .I \ GRAVEL D/M Ap' P � MONUMENT Trn K JUNIPER VALLEY SUBO. PACE 2 OF 3 .. KENNET....cl . ./ �1 z- e epi \\\\\\ A'bfE3310N�•' a..�u.e., r cconr _ RW M 1•eel\JuniDH TRENCH PLAN ABBREVIATIONS_ BOH . BOTTOM OF HOLE CO • CLEANOUT FCD • FOUNDATION CLEANOUT LF . LINEAR FOOT MT . MONITORING TUBE MH . MANHOLE PREPARED FOR: JEFF & SUSAN LAKOMSKI 10443 HIGH BLUFF DRIVE EAGLE RIVER. AK 99577 786-3566 FIELD BOOKS COw TEM. 9wwmr. , 4 DRAY . CI sTAww: NA 04ECKCD: KMO Asanr. NA DATE: 09/24 m rat: pno: SE704 ACRD fU: JOB "' 06-113 34. L2\06-1130—S9D1iC D9v9n.o.9 1 GRAPHIC SCALE 0 20 40 SCALE: 1 40' 'ii.J3��11�11 4� 4Np S� een i AX 99111.11"1 LOT 1 WASTEWATER DISPOSAL SYSTEM OVERALL PLAN Permit No. JUNIPER VALLEY SUBDIVISION BLOCK 4, LOT 2 Swoxxxx JUNIPER VALLEY SUBO. LOT 3 — MARIAN DRIVE—9 — — f— NO PUBLIC MTNIN 2005 OF PROPOSED SYSTEM. NO PRIVATE WELLS M IN 0' PROPOSED �. SYSTEM EXCEPT 20 20 %CEPT AS NOTED. GRAPHIC SCALE p 50 100 SCALE: 1 100' PAGE 1 OF 3 % OF AL4 .4 9 T.H*1 �E LSQFS DESIGN DETAILS 3 BDRM X 150 CPD- 450 CPD 450 CPD/1.2 GPD PER SO. FT. (1.5 MIN/IN.)- 375 SO. FT 375 SO. FT/2 x 4 D (Rock) - 47 FT. TRENCH USE 1 TRENCH- 47 (L) X 2' (W) X 4' (D) - 10' O.C. Total depth of system is 10' mox. from original grade. 471 / 30 HOLES - 1.6' SPACING W/ 3/16* HOLES Holes faced down or with manufactured caps & capped ends. NOTES. 1. INSTALL 1250 GALLON S.T.E.P. do INSULATE IF < 4' COVER. 2. INSULATE TRENCH WITH 2" HD BURIAL FOAM IF < 3' COVER. 3. CONTRACTOR WILL ENSURE MAXIMUM 2% SLOPE INTO SEPTIC TANK. 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS. SEPTICS. LOT LINES. FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FOR: JEFF do SUSAN LAKOMSKI 10443 HIGH BLUFF DRIVE EAGLE RIVER. AK 99577 786-3566 ........ - . ...... TKENN'011DU V ' CE- 16 4• � � .. 1 .1 �z�4 . T� / %FESS1011" / `%! FIELD BOOKS casuTEO, wuwmr. 0703/48 MAen: I srMlwc NA O"Emm: KMO Aseuar. fJq DATE' 09/24/ D.c. ME! a°° SE704 AM nL, JOB Nu' 06-113 \WELL h SEPTIC — riled By Lego)\Juniper Volley\84. L2\08-1130—Septic Dsefgn.dwq s llii.']��11�11 �Bti �ii�/�g011 L 74 � srfn-sTj6 MIZ lii]��11t1 ARXERRA NC. ENGUNEERING AND l\�!3JI1/�� n„p se- t SOILS PERCOLATION TEST Performed for. Jeff & Susan Lakomski Date Performed: 9 1 07 Project: Iutiler Valley loch d i n(2 TEST HOLE p T1107-1 Depth (Feet) SEE ATTACHED SITE PLAN ..^t I FOR HOLE LOCATION Drg/OL GP/SP—trace of silt SU — damp B.O.} I. ROLE PRESOAKED PRIOR TO TEST Was Ground water encountered? NO Depth to water after monitoring? DRY What depth? NA Date? 9/19/07 Reading Datc Gross Time Net Time Depth to Water Net Dro 1 9/19/07 10) T' 2 1:10 10 min DryT' 3 * 1:11 7" 4 1:21 10 min Dry 7" 5 * 1:22 7" 6 1:32 10 min 1/16" 6 15/16" 7 + 1:33 T' g 1:43 10 min 2/16" 6 14/16" 9 + 1:44 T. - 10 1:54 10 min 2/16" 6 14116" 11 * 1:55 7" 12 2:05 10 min 2/16" 6 14/16" + Water Added Percolation Ratc j.4 (minfin) Pere Ilole Diameter 6" Test Run Betwcen 6 feet and 7 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. �sTERM ARGlERRA iY1r ENGINEERING AND SURVEYING, INC. i Oft t t fnrrarN SOILS PERCOLATION TEST Performed for. ,Leff & Susan Lakomski Date Performed:09 1 07 Project: IuniDer Valley Block a j,ot2 TFST HOLE # T1107-2 Depth SEE ATTACHED SITE PLAN (Feet) r^ l FOR HOLE LOCATION Drg/OL GP/SP— trace of silt SNI—damp B.O.H. 17- 18- 19 - HOLE PRESOAKED 20- PRIOR TO TEST was Groundwater encountered? NO Depth to water after monitoring? DRY what depth? NA Date? 9/19/07 Reading Datc Gross Time Net Time Depth to Water Net —Drop 1 9/19/07 1:00 7 2 1:10 10 min 3/16" 6 13/16" 3 • 1:11 T' 4 1:21 10 min 5/16" 6 11/16" 5 + 1:22 7" 6 1:32 10 min 6/16" 610/16" 7 • 1:33 T' - 8 1:43 10 min 5/16" 6 11/16" 9 Y 1:44 7 10 1:54 10 min 5/16" 611/16" 11 • 1:55 7 12 2:05 10 min 6/16" 6 10/16" * Water Added Percolation Rate 1.5 (min/in) Perc Hole Diameter 6" Test Run Between 6 feet and 7 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. i ARCIERRA ENGINEERING AND SURVEYING, INC. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: JUNIPER VALLEY 134, L2 GENERAL: 1. The scope of this project includes the installation of a septic tank and/or drainfield to serve a single-family residence on the referenced property as delineated on the attached Municipality of Anchorage (MOA) permit and site plan. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 2. ArcTerra Engineering & Surveying, Inc. (ArcTerra) assumes no responsibility of the accuracy of the as -built survey provided by the owner or owner's representative. 3. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 4. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 5. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 6. The MOA Development Services Department On -Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two JUNIPER VALLEY B4, L2 September 24, 2007 Page 2 of 3 adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. 7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high -groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed -up) before gravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: Type of Pip Perforate s6d Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793 JUNIPER VALLEY B4, L2 September 24, 2007 Page 3 of 3 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 37o passing the #200 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or ADEC requirements. INSPECTIONS: Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non- compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and ArcTerra. ArcTerra shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. ArcTerra shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. ArcTerra's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER WASTEWATER SYSTEM (S), THE PROPERTY OWNER, AND/OR WELL DRILLER ACKNOWLEDGE HAVING READ AND ACCEPTED HESE SPECIFICATIONS. 20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868.3791 • FAX (907) 868-3793 i N JN Q 00 IN Q W 0 L. EGiION 61n. ! n W : a O O Q y J C6 � y a U J 0 a J J � _ ! Q S U p v>a W > C tJ li a A 1 01 N O MUNIGIPA�I"(Y 01 t W m PK W W (7 L. EGiION 61n. ! W : = C6 y J 0 a z w ud Z 3 n u p v>a a G C B �CI A 1 ren A 67 _ A MUNIGIPA�I"(Y 01 t PK EN�IRO;;�A�,11A� �.J �• l,, r��E�ts. � �' �YIF st i.t i •i: H. :.t A z - W a w p � vz VHi W 3 A w d L. EGiION 61n. ! t �nll %Z J Ili z p a p w z i rA = 0 tt tr : st i.t i H. w O O O 0 0 0 0 0 0 o 0 F [� E' [- f'• Ew H F � H [q o 0 A 0 o 0 p p 0 w w w w w w w w w w w w w cFt w w w O O O o 0 0 0 p 0 0 0 x x x x rx x x x 9 a W w w w w w w w w w w w t �nll %Z J Ili z p a p w z i rA o 0 A 0 o 0 p p 0 0 0 0 w w cFt w w w U. U. z w o 0 0 0 0 0 0 0 0 0 0 0 p w w w w w w w w w A w w c°, z t �nll %Z J Ili z p a p w z i rA Parcell.D. 050-751-47 6/V �- v e1Z Municipality of AnchoraOn-Site Water and Wastewater Program (907)343-7904 Certificate of On -Site Systems 1. GENERAL INFORMATION Expiration Date: I - Complete le*.description Juniper Valley, Block 4, Lot 2 Location (site address) 3945 Mariah Dr. ET Current Property owner(s) Spinell Homes Inc. Day phone Mailing address 1900 W Northern Lights Blvd #200 Anchorage, AK 99517 Real Estate Agent Day phone 2. TYPE OF DWELLING: Ix Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Il Individual Water Storage ❑ Holding Tank I] Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request Received by: A /t-kf j / Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $li�•c(r�j Waiver Fee $ 2 Date of Payment 7 Date of Payment Receipt Number 07LO6 Receipt Number COSA# OSC/6i3oJ' Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that n y investigation, based on procedures outlined in the Certificate of On -Site. Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or. wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordancTwith MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encounteredat t. the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend or tloogl foil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. Thes n88i¢ ns are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee fu ure performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warrant/ for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE System #1 Approved for LZ bedrooms System #2 Approved for bedrooms Disapproved Phone (907) 272-8218 Date 6/18/2016 • 16ven . 06r riorie Conditional approval for bedrooms, with the following stipulations: By rA Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet ° c If more than 1 septic system is on the lot: COSA Checklist #? of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Juniper.Valley, Block 4, Lot Parcel ID: 050-751 -47 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y Date completed 6/17/1983 Sanitary seal (Y/N) Y Wires properly protected (YIN) Y Total depth 520 ft. Cased to 254 ft. Casing height (above ground) � 2+ in. FROM WELL LOG ` AT INSPECTION Date of test 6/17/1983 6/6/2016 Static water level 260 ft. 214 ft. Well production 16.7 g.p.m. 5.0+ 9- p.m-WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate ND mg/L Arsenic -ND ug/L Date of sample: Z/6/2016 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material S.T.E.P./Steel Date installed 10/3/2007 Tank size 1,250 gal. Number of Compartments 2—. Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping New* Pumper N/A C. ABSORPTION FIELD DATA 10/3/2097 z z Date installed - Soil rating (g.p.d./ft or ft /bdrm} 1.2 GPD/SF Deep Trench System type Length 47 ft_. Width- 2 ft. Gravel below pipe A ft. Total depth 10 ft. Eff. absorption area 376 ftz Monitoring tube YDepression over. field N Date of adequacy test New Results (Pass/Fail) PASS For 'bedrooms Fluid depth in absorption field before test New in. Water added New gal. New depth New in. Elapsed Time: New' min. Final fluid depth New in. Absorption rate >= 450+ g p d Any rejuvenation treatment (past 12' mo.) (YIN & type) No If yes, give date D. LIFT STATION Date installed 10/3/2007 Size in gallons 1;250 "Pump on" level at 42 ' in. "Pump off level at 40 in. Datum Bottom of Tank Cycles tested pqe�* Manhole/Access (Y/N) X High water alarm'level at 45 in. Meets alarm & circuit requirements? Yes E. - SEPARATION DISTANCES -WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 1bb+ Public sewer main 75+. Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 1 OQ+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Absorption field + Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ - ABSORPTION FIELD ON 40T TO: Property line 10+ Building foundation 10+ Water main - r' Water Sevice line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Building was just built on the property. 5eptio'has never been in use. . *At date of well flow test tank was empty. **Slope waiver on file G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and. review of Municipal records that the above systems ale in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven PanTrone Date 6/18/2016 ti COSA canary sheet 2.6-IS.doc PLAT NO. 82--49 JUNIPER VALLEY SUBDIVISION LOT 2 g BLOCK 4 AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE GASTALD I LAND PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. I SURVEYING, LLC JEFF A. GASTALDI, R.LS. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, 2000 E DOWUNG RD.. SUITE" 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 89507 APPS ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES: SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR 3/30/2016 ESTABUSHING BOUNDARY OR FENCE LINES. SE705 ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. JVS24 NOTE: NO CORNERS SET THIS DATE 1,11-601 BUILDING DETAIL SCALE: 1 "=20' .P F:>•OF•••q� 4S a ••f.♦ ..... Jeffery A. Gaelaldl l g 0 LS -6091 1 O �O7eaalona�l-°c �'�