Loading...
HomeMy WebLinkAboutMCMAHON #2 BLK 5 LT 4MCMAHON-42 Block 5 Lot 4 #017-361-34 Development Services Department Building Safety Division On -Site Water & Wastewater Program G! 8L 4700 Elmore Road P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor www muni orq/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW Date of Issue: Parcel Identification Number:(9t7- 3G I.3 q Legal Description Foe�70wner � Name & AdTs: �)✓1 CA a _ �>�kTL 12 S� L 59S�L Pump Installation Date: V//Z'//` Pump Intake Depth Below Top of Well Casing: Cif,e/ feet Pump Manufacturer's Name: g__05�(<tl" Pump Model: es/2- Pump Size !Z hp Pitless Adapter Burial Depth: /0 feet Pitless Adapter Manufacturer's Name: 94&a 4i\a50^r Pitless Adapter Installer: ed 74 Well Disinfected Upon Completion" N -Yes ❑ No Method of Disinfection: Comments: Pump Installer Name: AW*P!5 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Inspection Report_t-1-12.iCG� Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151130 PID Number: 017-361-34 ❑ New ❑✓ Upgrade Name: Donald & Carla Williams ABSORPTION FIELD ✓❑ Deep Trench ❑Shallow Trench ❑Bed ❑Mound Address 13001 Norak Pl. ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 1.0 GPD/SF 12 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6 Ft. Gravel depth beneath pipe 6Ft. Subdivision Block Lot McMahon #2 5 4 - Fill added above original grade 0 Ft. Gravel length 50 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines I N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 600 Ftz 1 N/AFt. Well 140.3 132.6 N/A N/A 100+ TANK O Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity I 1,250Gal. Surface water 100+ 100+ N/A NIA Material Number of compartments Lot Line. 25.3 10.4 N/A N/A STEEL 2 NA Foundation 6.6 11.3 N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain N/A NIA N/A N/A Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer to­ PIPE MATERIAL House to tank 3034 Tdrainfield n eld 3034 A+ Home Services Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 100ft Inspection dates: t 6/4/2015 2w 6/4/2015 Location and description 3" 6/5/2015 e Back door threshold COMMUNITY DEVELOPMENT DEPARTMENT 0PROVAL Engineer's Stamp At Conditional Conditional Approval: Date • .... ���Q°(�G. ��* 49 T—H �/. n . F�annorae` CE 8149 Approved .W`7–�,S ��>,��'vlypt.,+� Date Inspection Report_t-1-12.iCG� \ l M WELL (E) i SEPTIC AREA (E) �l. 0 Q 0 o' w 0 0 ZF Wim= W_=W� i _132.1 � V ' DRIVEWAY —WELL (E) <) r \ v -L.QT 4 " O \ z � W- DRIVEWAY EWAY \ M2 l� 11 40R A OUSE (E) UPGRADED DRAIN FIELD NEW / 5OLF x 2.5'W x 6.0'ED x 12.0'TD L 10.4 TH-1 I / PREVIOUSLY ABANDONED - - SHED \ L \ SNED DRIVEWAY DRAIN FIELD (E) REMOVED ANY PART ENCOUNTERED WITHIN 12' OF NEW DRAIN FIELD AND REPLACED WITH SAND 1 WELL (E) DRAIN FIELD (E) IN FAILURE —RE -USE AS 4BR RESERVE WITH THE (FUTURE) ADDITION OF i 12LF x 3'W x 6.0'ED x 10.0'TD (NIC) I 1000g SEPTIC TANK I -DECOMMISSIONED PER CODE INSTALLED 1,250g SEPTIC TANK NEW WITH DC & DV - \ W z 1 �o 1 I \ 0 \ z SEPTIC AREA (E) \77 / / 0 - / o I / . WELL (E) RI i KUTCHER DRIVE f \I NOTES: PANNONE ENG IVC LLC �`�OF A ',,k Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 �(�p�r4S�+l', s/u/2o15 PHONE (907) 272-8218 FAX (907) 272-8211 ig�p 'lb.t scale McMAHON #2, BLOCK 5, LOT 4 DONALD & CARLA WILLIAMS 13001 NORAK PLACE PLAN ANCHORAGE, AK 99516 {7 �/ 1"=50' P.I.D. NO .,.*-017-361-34 inone� PERMIT NO. OSP151130 2 OF A B T1 21.1 59.3 T2 21.8 58.8 DC 22.2 58.8 DV 22.7 58.9 M1 13.0 47.1 C1 14.6 48.2 M2 40.3 16.9 C2 40.4 17.7 NOTES: PANNONE ENG IVC LLC �`�OF A ',,k Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 �(�p�r4S�+l', s/u/2o15 PHONE (907) 272-8218 FAX (907) 272-8211 ig�p 'lb.t scale McMAHON #2, BLOCK 5, LOT 4 DONALD & CARLA WILLIAMS 13001 NORAK PLACE PLAN ANCHORAGE, AK 99516 {7 �/ 1"=50' P.I.D. NO .,.*-017-361-34 inone� PERMIT NO. OSP151130 2 OF SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS. 2. SCOPE OF WORK: DECOMMISSIONED EXISTING SEPTIC TANK PER CODE AND INSTALLED NEW 1250g SEPTIC TANK AND SOIL ABSORPTION SYSTEM. _ 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18. FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. NO AN APPARENT WATER TABLE WAS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE. - - - - - _ - - FILTER FABRIC - 4" 0 DRAIN PIPE - - DRAIN ROCK 6" ABOVE PIPE INV TH-1 ABBREVIATIONS - R. 1. RIGID INSULATION TANK SIZE: 1250 SEPTIC CU -0.5 R DCO DOUBLE CLEAN OUT LEGEND DIP DUCTILE IRON PIPE DV DIVERTER VALVE. SOIL RATING: 1 GPD/SF TH TEST HOLE FS FLOW SPLITTER AREA ROD: 600 SF FC FOUNDATION CLEAN OUT BFG W - WATER LINE/ -5A � - - T - # WELL RADIUS FG FINISH GRADE - - C# CLEAN OUT NO. -TOPSOIL sM/ 6.0 sw-- TS&V �— SS NEW SEPTIC MONITOR TUBE NO. NIC NOT 1N CONTRACT - 87.0 - - SECTION 6.0 L w w m m 00 0 0 w0 w - o FILTER FABRIC o o �w z w o 4"m DRAIN PIPE 0 :F womWw o >_ DRAIN ROCK 6" u n n n nn n n n ABOVE PIPE INV In In 93.7 I 1,2509 SEPTIC TANK NEW -PROFILE DESIGN PARAMETERS PRIMARY SEPTIC. SYSTEM - - NO. BEDROOM: 4 (600 gpd) ABBREVIATIONS - R. 1. RIGID INSULATION TANK SIZE: 1250 SEPTIC CU COPPER - DCO DOUBLE CLEAN OUT PERC RATE: <1 MPI DIP DUCTILE IRON PIPE DV DIVERTER VALVE. SOIL RATING: 1 GPD/SF TH TEST HOLE FS FLOW SPLITTER AREA ROD: 600 SF FC FOUNDATION CLEAN OUT BFG BELOW FINISH GRADE SYS. TYPE: DEEP TRENCH 6.0'EDTANK-CLEAN-OUT OG ORIGINAL GRADE MIN LENGTH: 50 LF T - # N0. FG FINISH GRADE - - C# CLEAN OUT NO. -TOPSOIL TS&V AND VEGETATE USED: - M# MONITOR TUBE NO. NIC NOT 1N CONTRACT 50 LFx2.5'Wx6.0' E.D.; 12.0' TD TOTAL AREA: 600 SF - - - NOTES: PANNONE F,NG-SVC, LLC RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 DRAWN BY: NJC DESIGN DETAILS McMAHON #2, BLOCK 5, LOT 4 DONALD & CARLA WILLIAMS 13001 NORAK PLACE ANCHORAGE, AK 99516 7/30/2015: - '•'Fy%I Scale •.••. *1/ NTS P.I.D. NO -atT`351-34 roen R� Pannone PERMIT NO. - CE 8149 OSP151130 P�'PR�OFESSIOVE Sheet X OFES -. 3 OF 3 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151130 Tax Code Number: 01736134000 Work Type: Septic Upgrade Permit Effective Dates: June 02, 2015 to June 01, 2016 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: MCMAHON #2 Site Legal Address: MCMAHON #2 BLK 5 LT 4 G:2835 Owner/Address: WILLIAMS DONALD W & CARLA J 13001 NORAK PL ANCHORAGE AK 995162848 Site Mailing Address: 13001 NORAK PL, Anchorage Lot Size in Sq Ft: 30150 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage ld'3-d 37 3� All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: If the existing 3 bedroom system is not decommissioned but a diverter valve is used, a note must be made on the Inspection Report stating that if the fourth bedroom is added, only the system designed for 4 bedrooms shall be tested for any future COSAs. 6151j.s Change QW er �vfa f D�fh e 7-1-rc icK 12' -ho 9ef 9ruvc�y �Irvw S r0M 7%A 1S Received Issued By: 6 MW_1r IM MUNICIPALITY OF ANCHORAKIBITTA` MAY 18 2015 Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-361-34 Propertyowner(s) Donald & Carla Williams Day{phone Mailing address 13001 Norak PI., Anchorage, AK 99516 Site address 13001 Norak PI. Legal description (Sub'd., Block & Lot) McMahon #2, Block 5, Lot 4 Legal description (Township, Range & Section) Lot Size 30,150 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑x Initial F-1 Single Family (SF) 19 (w/wo ADU) Septic Tank Upgrade ❑x Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or Permit/Rush Fees: Date of Payment: _ Receipt Number: _ Permit No. Permit App_:; :'-._c, Waiver Fees: Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services uc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(cDpanen¢ak.com June 2, 2015 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Rd. P. 0. Box 196650 Anchorage, Alaska 99519 Subject: McMahon #2, Block 5, Lot 4 Septic System Upgrade Permit Request Ladies and Gentlemen: I am writing request a permit to construct an upgrade four (4) bedroom septic system on this property. Currently the lot is developed. The existing drain field is in failure and will be re -used as a reserve, with a future addition to accommodate an additional bedroom. An upgrade drain field will be constructed. The existing 1000g septic tank will be decommissioned per code and a 12508 septic tank will be installed. This lot and the surrounding lots are served by private wells. There are no wells within 100' of this system. Soils. P.E.S. performed one test hole in the vicinity of the drain field in May of 2015, and groundwater was monitored for seven days. Ground water was not observed to a depth of 18.0 feet below the ground elevation in the test hole monitor tube after the seven day monitoring period. It is my opinion, based on the results of the soils tests and overall soils appearance; an application rate of 1 gallons/day/square feet should be used for a conventional wastewater system. 1. Soil Absorption System Design. a. See Sheet 2 of the design package. 2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 3. Topography: The existing topography slopes generally from west to east in the area of the septic system, with a slope of approximately 2% in the immediate area of the upgrade. There are no steep slopes within 50' of the proposed drain field location. 4. Drawing Markings: The Drawings are marked "For MoA Review Only'. When written notification that the review is complete and that there are no further comments is received from MoA On -Site Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no surrounding wells within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 u J M WELL (E) AtA`� i �'\ \ SEPTIC AREA (E) 11 J 0 0 0 CEw Of 0 DRIVEWAY l II WELL (E) , j1 48R 11.2 HOUSE —LOT 4 a o y ��. SH \N z \N�� ��-- W_—DRIVEWAY \ SHED 1 DRIVEWAY) UPGRADE DRAIN FIELD (P) POLE x 2.5'W x 6.0'ED x 11-.O'TDFf / TH-1 / \ PREVIOUSLY ABANDONED — DRAIN FIELD (E) REMOVE ANY PART ENCOUNTERED WITHIN 12' OF DRAIN FIELD (P) AND REPLACE WITH SAND j 1 WELL (E) 3 i DRAIN FIELD (E) IN FAILURE - RE -USE AS 4BR RESERVE WITH THE (FUTURE) ADDITION OF i '- 12LF x 3'W x 6.0'ED x 10.O'TD (NIC) w 1000g SEPTIC TANK (E) DECOMMISSION PER CODE w , INSTALL 12nOg SEPTIC TANK (P) W� WITH DCO :�. -S z ( SEPTIC AREAA(E) 777 WELL (E) 1� x i ! [ KUTCHER DRIVE I NOTES: s�t��n�\\ Date PANNONE ENG SVC, LLC or-. a4 �i 6/2/2015 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r'��' •'"qS 1� PHONE (907) 272-8218 FAX (907) 272-8211 /ig�`p �y+/) Scale . / 4 / ..... .. .. . / R.I.D. No McMAHON #2, BLOCK 5, LOT 4.... .. ... 77-T61-34 DONALD & CARLA WILLIAMS / St .. ..even R. Pannone / PERMIT NO. 13001 NORAK PLACEl��P�cJ CE 8149��/ OSP151130 PLAN ANCHORAGE, AK 99516 ii1PF�PROFESSIONPV� Sheet SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS. 2. SCOPE OF WORK: DECOMMISSION EXISTING SEPTIC TANK PER CODE AND INSTALL NEW 1250g SEPTIC TANK AND SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. FILTER FABRIC 4" 0 DRAIN PIPE DRAIN ROCK 6" ABOVE PIPE INV TH-1 --OSR -iT�Aa I -TEA - LEGEND DM =L W WATER LINE/ -5.0 - - WELL RADIUS I SM/ sw — SS NEWSEPTIC 7.0 SECTION L e.a w w m m 'o 0 0 o a FILTER FABRIC a o w w w z 4" 0 DRAIN PIPE z w w 00 0 0 M DRAIN ROCK 6" M ABOVE PIPE INV i-aIF- L___j j� L — 12508 SEPTIC %' -x�v a _ PROFILE DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) ABBREVIATIONS - R.I. RIGID INSULATION TANK SIZE: 1250 SEPTIC CU COPPER DCO DOUBLE CLEAN OUT PERC RATE: <1 MPI - DIP DUCTILE IRON PIPE DV DIVERTER VALVE SOIL RATING: 1 GPD/SF TH TEST HOLE FS - FLOW SPLITTER AREA ROD: 600 SF FC FOUNDATION CLEAN OUT BFG BELOW FINISH GRADE SYS- TYPE: DEEP TRENCH 6.0'ED OG ORIGINAL GRADE MIN LENGTH: 50 LF T# TANK CLEAN OUT NO. FG FINISH GRADE C# CLEAN OUT NO. - TS&V TOPSOIL AND VEGETATE USE: - _ M# MONITOR TUBE NO. - NIC NOT IN CONTRACT 50 LFx2.5'Wx6.0' E.D., 11.0' TD TOTAL AREA: 600 SF NOTES: 77���� �'+T�T �{� Ptll`l19G1V1'.. ENG SVC, LLC P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-82 ��QF q \\l - �gsll1 P. fF9 7F{ -�� ..... .. .. .. •. ...... . .. .... . . Date s/z/zo15 CONSTRUCTION NI NTS McMAHON #2, BLOCK 5, LOT 4 P.LD. NO 361-34 DONALD & CARLA WILLIAMS S St R- Pannone / CE 8149 PERMIT NO. 13001 ANCHORAGE, NORAK PLACE AK 99516 9.•, clir 1 0 ESSI OSP151130 DESIGN DETAILS sheet 2 OF 3 READING SOILS LOG - PERCOLATION TEST CLOCK TIME TEST HOLE 1 WATER LEVEL READING NET DROP 1 SLOPE ` \\1 ITE I LAN \ OR ORGANICS 1.25 --- 1 � � 2 7.25(DRY) /3 GM SILTY GRAVEL I TH-1 --- \ g a DRIVEWAY 10:45 5 MIN 7.25(DRY) 6.D0 6 - x 4BR 10:45 --- TH HOUSE --- 7 (E) j � 5MIN 7.25(DRY) 6.00 8 �T 4 wl 10 SHEuI 11 SM/ SILTY SAND/ DRIVEWAY \ \ aED 12 SW SAND. w \ DRIVEWAY �- 13 WAS GROUND WATER SLOPE 14 ENCOUNTERED? N 15 IF YES, AT WHAT TH DEPTH? -DRY x 1s 17 DEPTH TO WATER AFTER MONITORING? -DRY 18 DATE: 5115/15 BOH DATE PERFORMED: 05/08/15 PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 5 FT AND 6 FT COMMENTS: Test hole excavated by A+ HOME SERVICES. Prec hole was presoaked. Test run for at least one hour. Last 3 readings reported PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUID7L�IINNES IN EFFECT ONTTHE OF THIS TEST. NOTES: �rDATE PL-11�I1VONE ENG SVC, LL,C P.O. BOX 102954 ANCHORAGE, AK 99510 ���QF Q \�l S�� • Cgsl�+ �*f Date x/2/2015 FOR CONSTRUCTION Scale PHONE (907) 272-8218 FAX (907) 272-8211 %6j�p �.�.: .*�/ ..... .... NTS P.I.D. NO McMAHON #2, BLOCK L, LOT 4 .. ...... .. .. .. 017-361-34 DONALD & CARLA WILLIAMS Steven R Pannone CE 8149 PERMIT NO. 13001 NORAK PLACE .•<?% f.. +l`li�\ OSP151130 SOILS LOG ANCHORAGE, AK 99516 Sheet DFES 3 READING DATE CLOCK TIME NET TIME WATER LEVEL READING NET DROP 1 05/08/15 10:35 --- 1.25 --- 2 10:40 5 MIN 7.25(DRY) 6.00_. s 10:40 --- 1.25 --- 4 10:45 5 MIN 7.25(DRY) 6.D0 5 10:45 --- 1.25 --- 8 11:50 5MIN 7.25(DRY) 6.00 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division > 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 d ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name DISTANCES oRF TO SEPTIC ABSORPTION WELL Address FROM TANK FIELD 2-Le-2—Lo obi Phone(s) Permit No. No. of Bedrooms WELL , pp \ 'ir- C%:> LOT LINE LEGAL DESCRIPTION Lot q Block S bdi Suvision t, M "-D to It FOUNDATION 'k-- ` + Township, Range, Section AS-BUILT DIAGRAM (Show location of well, septic system, property lines, foundation, driveway, water bodies, etc.) TANKS 64 SEPTIC ❑ HOLDING ' l t +7 Manufacturer , 1 specify yin-�gallons VO D Material No. of Compartments Z l TYPE OF SYSTEM TRENCH ❑ BED ❑ W. DRAIN ❑ OTHER Depth to pipe bottom from - Total depth from original grade original grade FT Q FT Fill added above original grade - Gravel depth beneath pipe 0 FT to FT Gravel length Gravel width 4t Q 5& FT +2, Total absorption area Distance between lines ^ 445 L.0 SQ FT D FT c VS Number of lines ' Soil rating I \zjb SQ FT Pipe material 'pV t -34 Installer S`r� ^ I I Date Installed 10 � 4 -tet co FIF WELLS fvf i..�10 • k ^ un L. PRIVATE El OTHER (Identifvl _ C W S O Classification (A,B,C) Total Depth Cased to .r�'� f D if15Tt/`lLei FT FT Installer Date Installed: iAS >?: REMARKS: (� ( Scale: ` I Inspectlonormed by: ENGINEERS SEAL gS i-2rS ° } t Date: 1 ��� �%reF_q�i 00 % 1 z�,5 4�s' Z75` E9 ' ryry SF, GIS4E¢ING �t q,��95nyI�®orf D610 2Q4 cedily that this inspection was performed according to all a: _ Municipal aneoril. M rirf alliptifis ifale? R<o. L2'v �S� Ltd Health Department Approval: Date: �1 n '°'U,•� ��`'';;,;' <'Dri 72-013 (3/85) ~ Signed: DATE: �Dwner) JOHN ��ESS lssued 8y: DATE: MUN1C1PA1..ITY OF ANCHORAGV- I' Health & I- ITE SEWER 1 'FIE PERMIT Permit Number: 90028 Upgirade Uate lssued: 09/11/90 Engineer Designed Day Phone: Dwner Name: JOHN kRESS Owner Address: 2626 GLENWOOD ST, 786-1489 ANCHURA�E,AK 99508 J � Parce] I�: 017~+�,�f�� Lot Lega]: Subdivision: MC MAHON 412 Loix 4 Block: 5 Section: 29 Township: 12N Range4 3W Lot Size 30150 (sq,Ft. or acres) Max Bedrooms: This Permit: 3 Total Capacity: 3 SEPTIC TANK: Minimum total septic tank capacity: 1�000 gallons, Each septic tank haveleast 2 Depth to top of septic tank(s) < 4.0 must at compartments" feet requires insulation over Lank(s), INSTALL PER ENGINEERS ATTACHED PLAN` NOTIFY DHHS PRIOR TD EACH INSmCTION. THIS PERMIT IS ISSUED FOR THE EXISTING 3 BEDROOM SINGLE FAMILY DWELLING ONLY AND EXPIRES ON 12/31/90, I CERTIFY THAT: 1. I am /amilWar, with the or on-site sewers and wells as set !orth by the Municipality o� Anchorage (MOA) and the State o� Alaska. 2. I will install Lhe system in accordance with all MOA codes and regulations; and in compliance with the design criteria o this permit. 3, I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well�j wastewater disposal system or public sewerage system on this or any adjacent or, nearby lot" 4, I understand that this permit is valid for a maximum o[ 3 bedrooms. I that the o{ the iotal system is 3 bedrooms and also understand capacity any enlargement will require an additional permit" ~ Signed: DATE: �Dwner) JOHN ��ESS lssued 8y: DATE: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST (ENG INEER'S'SEAL) N Y> y05��> OU JU6Y4iB:ll 119 <0.�<e �. +f YJ r. aev ea •oao e° , V PERFORMED FOR: ,MP `.J 0/1 Pj l\ (<C, DATE PERFORMED: LEGAL DESCRIPTION: /�'r/-I) I&KS- A&c AA jHCA.) /W,j ; TON DEPTH (FEET) r ti 2 r n � r 3 °. 0 4- 5 5 6 ° a -o ' 0o 7 u 13- 14- 15- 16- 17 314151617 18- 19- 20- COMMENTS 81920COMMENTS — ;tion: SITE PLAN INN ■■ A .■M■ MEFAN ■■I.■ MEMO ■ENE ORION MEMO WAS GROUND WATER ENCOUNTERED? �C) s L IF YES, AT WHAT O DEPTH? P - '- E Depth to Water After Monitoring? &— Dale: 0 Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN —G)FT AND FT PERFORMQ&q:Ei33�££,,i''{E$,F(i1C ��Jj (ry�� ryry�p�d� I CERTIFY THAT TH S TE T WAS PERFORMED IN ACC0RDA IWtL�TnlEEOANII op U MPAFRIDELI N EFF;CT ON THIS DATE. DATE: Eagle River, A asks 72-008 (Rev. 4/85) NAME z LOCATION �\ GRE,.. , ER ANCHORAGE AREA BW JGH00""! Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM t� MAILING ADDRESS /1900 'X04 e�Q` PHONE, 5 LEGAL DESCRIPTION L/ tl?(f SEPTIC TANK: DISTANCE `} NUMBER OF FROM WELL MANUFACTURER_ MATERIAL .-� / COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY/a-YJ GALLONS. TILE DRAIN FIELD : jjjf_td )))1""""""l,p///+++,,L,_L DISTANCE FROM WELL FOUNDATION NUMBER OF LINES DISTANCE BETWEEN LINES TOTAL LENGTH NEAREST LOT LINE OF LINEjf 4t /6 J TRENCH WIDTH— IN. TOTAL EFFECTIVE ABSORPTION AREA �`C5 SQ. FT. LENGTH OF EACH LINE f DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE :% MATERIAL BENEATH TILE—.1—SA. ABOVE TILE WELL: i� TYPE_ f� CONSTRUCTION BUILDING NEAREST NEAREST SEPTIC FOUNDATION LOT LINE , SEWER LINE , TANK_ CESSPOOL . OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: INSTALLED BY: 5 SEWER LINE DEPTH: PIPE MATERIAL: `-Z? LOT SLOPE: REMARKS: Form EQ -032 `/ I N. EPTH DISTANCE FROM: SEEPAGE SYSTEM_ DIAGRAM OF SYSTEM 1 ' G.A.A.B. � � . DEPARTMENT Or HEHAH HND ENVlRONMENTHL PECTION ^ 2516 E�� TI RD./ HNCHORHGE3 HK� *�9507 . 276-2221 ^' ' � ����, ��_�����'o . � PERMIT NO ( �6559 ) ` HPPLICHNT JOH' ESS ' 1800 MCKIN�EY HVE �77�5�96 � � Ci L: NORHK PLHCE / � � � i L�� ��IZE�� ]�150 SQUMRE FEET LEGHL L4 B5 MCMHHON'5UB� �* � �� ' ` ' . `'/' TYPE OF SOIL HBSORBTION SYSTEM IS: TRENCH' MHXIMUM NUMBER OF BEDROOMS (SQ T/BR)= 150 THE REQUIRED SIZE OF THE SOIL HBSORPTI(IN SYSTEM IS: ��P" A 4 A =:- �C�-D �1"11 C� -I- I—P -=. zoos, fill If: Vol Rvu TE. 1, Ell �F" -T- &A�= THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND HND THE BOTTOM OF THE EXCHVHTION (IN FEET) THERE IS NO SET WIDTH FOR TRENCHES. THE GRHVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE HND THE BOTTOM OF THE EXCHVHTION (IN FEET). 10MEATTU 1 IFTIMICIA STUM-1- :1, (11 lT" I? IWO Ul 9 a �����Nil �� BHCKFILLlNG OF HNY SYSTEM WITHOUT FINAL INSPECTION AND HPPROVHL BY THIS DEPHRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTHNCE BETWEEN H WELL HND HNY ON—SITE SEWHGE DISPOSAL SYSTEM IS 100 FEET FOR H PR -1.` -.4 -'ITE WELL OR 200 FEET FOR H PUBLIC WELL WELL LOGS HRE REQUIRED HND MUST BE RETURNED TO THE DEPARTMENT WITHIN ]0 DHYS OF THE WELL COMPLETION. SPECIFICHTIONS HND CONSTRUCTION DIAGRAMS ARE HYHILHBLE TO INSURE PROPER INSTRLLHTIOhl. low ERRI A! 141 1: 0- MIR U 1 RD I C INH E,---. "ru K Fol F=- O -v I �=o-, L -P FEE' I CERTIFY THHT 1: I HM FHMILIHR WITH THE REQUIREMENTS FOR ON ----SITE SEWERS HND WELLS HS SET FORTH BY THE MUNICIPHLITY OF HNCHORHGE. 2: I WILL INSTHLL THE SYSTEM IN HCCORDHNCE WITH THE CODES- ]: I UNDERSTAND THHT THE ON --SITE SEWER SYSTEM MHY REQUIRE ENLHRGEMENT IF THE RESIDENCE IS REMODELED TO I NCL E MORE THAN ] BEDROOMS. SIGNED~�~ This log represents subsurface soil conditions within McMahon Subdivision Lot 4 Block 5 DW N: o o F.B. Sanitary Sewer Sy Stean GRID CKD R&M CONSULTANTS 1i�iC Dp �. 7/21/76 EH °,v..». a.° a,,,.a a off .A A e.°A. John Kress PROJ.N0 656272 SCALE Anchorage, Alaska DWG.NO. A–01 Test Pit 1 f 0° a ti ORGANIC MATERIAL This log represents subsurface soil conditions within McMahon Subdivision Lot 4 Block 5 DW N: o o F.B. Sanitary Sewer Sy Stean GRID CKD R&M CONSULTANTS 1i�iC Dp �. 7/21/76 EH °,v..». a.° a,,,.a a off .A A e.°A. John Kress PROJ.N0 656272 SCALE Anchorage, Alaska DWG.NO. A–01 Test Pit 1 7/20/76 0° a ti ORGANIC MATERIAL `• � . —_ — ---51 — SILT W/SOA1E TR SAND U' SANDY SILT – SILTY SAND W/TR ORGANIC MATERIAL 41 SAND W/SOME SILT TR GRAVEL ro•• 6.5' GRAVELLY SA14D W/TR SILT (SP) b• - - -• - SAND b4/SOME TR GRAVEL :•: (SP) o 11' 5 G0 .0-0. Gravelly Sand (SP) o"g �'•a 15' TD NO WATER IN TEST PIT This log represents subsurface soil conditions within McMahon Subdivision Lot 4 Block 5 DW N: o o F.B. Sanitary Sewer Sy Stean GRID CKD R&M CONSULTANTS 1i�iC Dp �. 7/21/76 EH °,v..». a.° a,,,.a a off .A A e.°A. John Kress PROJ.N0 656272 SCALE Anchorage, Alaska DWG.NO. A–01 o NJ- R &M C0-,4SJLTAN-rS, INC. 249 EAST 51 ST. AVE.- SOX 6087 - ANCHOPAGE. AK.995O2 - P.M. 907279-0483 - TLX. 00023360 July 22, 1976 R & M No. 656272 Mr. John Kress 1800 McKinley Avenue Anchorage, Alaska RE: Test Hole and Soil Log Report for Sanitary System McMahon Subdivision Lot 4 Block 5 Section 28 T -12N R3W Dear Dir. McKinley: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of July 10, 1976 and those procedures outlined in a letter dated July 15, 1975, by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test pit was put down within subject site for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor -mounted Backhoe.and the test pit was extended to a total depth of 15 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test pit while drilling. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R& M CONSULTANTS, INC. James W. Rooney Vice President JWR/ddp xc: GAAB ANCHO=IAGE FAIRBANKS - - JUNF-AU • 00 hgl M 900oo rj ----� LO D z Z o� a QO 2KQ •� fm1 ti V gni LO 6 FU pews W Ica / �. ° � �.q`•Bpee t ••n••o b7s ti • • �7 ry } O ! Y 1 � LIJ � s e •_ tlr • J A LL. ILJ y' • B OU. J —M► coW al :2 A m I J:tea® M,90.00N 00 hgl M 900oo rj ----� m� �•LU fff z Z o� a QO 2KQ •� fm1 ti V gni LO 6 FU pews W ` / ° � N CD °' LIJ m O UO a� s J —M► coW al :2 I 00 hgl M 900oo rj ----� L�f � 11.E � s s n m 4 D t ` r f Jj 1 z G) n D z l/'i.`` ` t D o '\ 1 �! � - - � G3 +� r 1" h+ n > y q 0 - m v S 1 l m z z O 1 C 1 rO v` m r r,. :: n Parcel I.D. 017-361-34 Municipality of Anchorage On -Site Water and Wastewater Program 'c (907)343-7904 sne e.rx Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Expiration Date: / / — 7 I Complete legal description McMahon #2, Block 5, Lot 4 Location (site address) 13001 Norak PI. Current Property owner(s) Donald & Carla Williams Mailing address Real Estate Agent Day phone 13001 Norak PI. Anchorage, AK 99516 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Fx_1 Individual n Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment 1311145 c Date of Payment Receipt Number 09C'.i35WZ Receipt Number COSA # i5C✓i 51 1,�Co Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under theconditionsencountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sale benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Address P.O. Box 100217, Anchorage Alk. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE 1 .y System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Phone (907)272-8218 Date 0/11/2015 Conditional approval for bedrooms, with the following stipulations: By: Original Certificate Date: j / - Ls f The�.Munici)S�fty�1[if chorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSH Checklist X Nitrate Advisory .�. Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet � - , If more than 1 septic system is on the lot: COSA Checklist # + of Structure served by this system I Certificate of On -Site Systems Approval Checklist Legal Description: McMahon #2, Block 5, Lot 4 Parcel ID: 0 17-361 -34 CWYA :110 17-34 0 Well type Private If A, B; or C provide PWSID # Date completed 10/30/1976 Sanitary seal (Y/N) Y Total depth 100 ft. Cased to 100 ft Date of test Static water level Well production FROM WELL LOG 10/30/1976 Well Log (Y/N) .Y Wires properly protected (Y/N) Y Casing height (above ground) 12+ in. AT INSPECTION 6/10/2015 Unknownft 67 3 2.1 g.p.m. — ft. WATER SAMPLE RESULTS: Coliformcclonies/100 mL Nitrate i�mg/L Arsenic 1 ug/L Date of sample: '� Collected by: S B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Date of pumping New Depression over tank (Y/N) N Pumper N/A Date installed 6/4/2015 Cleanouts (Y/N) Y High water alarm (Y/N) N C. ABSORPTION FIELD DATA Date installed 6/5/2015 Soil rating (g.p.d./ftz or fe/bdrm) 1 GPD/SF System type Deep Trench Length 50 ft. Width 2.5 ft. Gravel below pipe 6 ft. Total depth 12 ft. Eff. absorption area 600 if Monitoring tube Y Depression over field N Date of adequacytest New Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test New in. Water added New gaL New depth New in. Elapsed Time: New min. Final fluid depth New in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) No If yes, give date M J D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons Manhole/Access (YIN) in. "Pump off" level at in. High water alarm level at Cycles tested Meets alarm & circuit requirements? E. SEPARATION -DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ Absorption field on lot 100+ Public sewer main 75+ Sewer /septic service line 25+ Animal containment areas 50+ SEPTIC/HOLDING TANK ON LOT TO: On adjacent lots 100+ On adjacent lots 100+ Public sewer manhole/cleanout 100+ Holding tank 100+ Manure/animal,excrete atorageareas 100+ Building foundation 5+ Property line 5+ Water main 10+ Water service line 10+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION l certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven R. Pannone Date 6/11/2015 COSA canary sheet_2-6-15.doc Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 10+ 2 0 Municipality of Anchorage Community Development Department Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 151400 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 5, Lot 4 of McMahon #2 subdivision. This inspection revealed a nitrate concentration of 8.97 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. 0 0 vv o 0 N N 22 �ja O A m� rnAD Vl (N/1Nm G N -.� •o o m a z x ° D 3 O a NORAK PLA — — m — — ELMORE. STREET 3M-sr6 n' ° , I 3nv =O =S smwa -4a. Sfa q a M Y a e 60. ° �. 'c m 3asaQws mq � °meq®a. 7f-. 3ac -ter - e°i O am m q-giiG g� � �a9�cyiSe 3° -` M. p q X = and ZC. a 00 a a a a p m o_ vm, n,t`uo z o �' S3s�som' • a m ° Z a Tm oo tr 2z°`m"o o= a,a 3.. a qao s9 qr S q iV c 0 n "140 ea CL a + 0 1 ' uA r a M' <nV o ° a w a.. rt =O Qq rw oZo� v3 aS .ar.7 to �a O p ® a0 7 q Ym 0 0 vv o 0 N N 22 �ja O A m� rnAD Vl (N/1Nm G N -.� •o o m a z x ° D 3 O a NORAK PLA — — m — — ELMORE. STREET MUNICIPALITY OF ANCHORAGE • DEPARTMENT OF HEALTH i£ HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.# 0\-I — 6ln\ " )q HAA # 1. GENERAL INFORMATION Complete legal description Location (site address or directions) V3, I N 0 -ra- V, L--) la. ce Property owner Dyo,2,( P V ,1 11 + ac vz-r g Day phone a& Mailing address / 30 0 'F7 14 - Lending agency Mailing address. Agent Address Unless otherwise requested, HAA will be held for pickup. V 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual well t"' Community well Public water Day phone Day phone NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: 6" Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025(Rev.1/91) Front MOA#21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as.of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe; functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm - �v 4� l o-, v t t ✓ Phone �:7q ` Srl 16 Address Engineer's signature 6. DHHS SIGNATURE l� Approved for Disapproved. 2 Conditional approval for Additional Comments bedrooms. Date bedrooms, with the following stipulations: The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an ii dependent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: 111, plt Parcel I.D. l L� A. Well Data Well type If A, B, or C, attach ADEC letter. ADEC water system number jj __NA. Log present (Y/N) y Date completed I �/-A0I �� Driller UV11vt-licl ./" Total depth too Cased to Casing heights Sanitary seal (Y/N) Wires properly protected (Y/N) FROM WELL LOG Date of test Static water level Well flow Pump levell SEPARATION DISTANCES FROM WELL TO: AT INSPECTION q rR rri g.p.m. �� g.p.m. C oo NO rrl w Septic/holding tank on lot � l V 0 ; On adjacent lots i 14 a Absorption field on lot > &C ; On adjacent lots ~l 1 L1 O Public sewer main NIA Public sewer manhole/cleanout !/A Sewer service line �> So Petroleum tank q 10 WATER SAMPLE RESULTS: r Coliform / Nitrate s, L"> 63 Other bacteria Or Date of sample: 7! c�3 /a _3 Collected by: B. SEPTIC/HOLDING TANK DATA Date installed 16 l ® Tank size" Compartments 411 Cleanouts (Y/N) ' Foundation cleanout (Y/N) Depression(Y/N) High water alarm (YIN) / /A Alarm tested (YIN) g t -//A Date of pumping f la 3 Pumper G,1J dwk [. S SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot ! l q L On adjacent lots ® L/O Foundation 81. To property line } 1 i? Absorption field Water main/service line > Eo Surface water/drainage 72-026(3/93)`Front CONTINUED ON BACK PAGE C. LIFT STATION 4 V 0 vtt Date installed Manufacturer Size in gallons Manhole/Access (Y/N) Vent(Y/N) High water alarm level "Pump on" level at Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot D. ABSORPTION FIELD DATA On adjacent lots "Pump off" Level at Cycles tested Surface water Date installed j 0 �� � g D Soil rating (GPD/Ft2) '� System types r �L i Length -3 6 Width ' Gravel thickness Total depth Total absorption area Y =; %7, Cleanout present (Y/N) Depression over field (Y/N) Date of adequacy test 6/1 1 /q-'5 Results (pass/fail) for T� Bedrooms r Water level in absorption field before test �� �% After test b Peroxide treatment (past 12 months) (Y/N) SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot On adjacent lots —a If yes, give date Property line !> 10, To building foundation '7�7 ;i--- To existing or abandoned system on lot On adjacent lots 1>i/ V c� Cutbank N 0 w -_ Water main/service line > 9L) Surface water N` to V 4;-�- Driveway, parking/vehicle storage area > 9 O Curtain drain t\) to E. ENGINEER'S CERTIFICATION 1 certify that 1 have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. HAA Fee $ ` 6 « Waiver Fee $ Date of Payment 7 -�-A' S� Date of Payment Receipt Number la-zf xs-Z t <l/Q,0 Receipt Number_ 72-026 (3103)' Back MUNICIPALITY OF ANCHORAGE • Department of Health & Human Services DIVISION OF ENVIRONMENTAL SERVICES •� 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D. # (n 1 - i� ' " — HAA # 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 4;.Block 5; McMahon Subdivision Addition Location (address or directions) 13001 Norak Place, Anchorage, Alaska (b) Property owner John Kress Telephone: (home) 277-5482 Business 7R6-1 4RA Mailing Address 2626 Glenwood Street, Anchorage, Alaska 99508 (c) Lending Institution Mailing Address (d) Real Estate Company and Agent Address Telephone Telephone (e) Mail the HAA to the following address: (or check here E�, if hold for pick up.) List contact person and day phone number below: S & S ENGINEERING/694-2979 17034 Eagle River Toop Road Suite 204 Eagle River Alaska 99577 2. TYPE OF RESIDENCE Single -Family 0 Number of bedrooms 3 3. WATER SUPPLY Individual Well KX Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site ® Public ❑ Community ❑ Holding Tank ❑ Note: if community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7788) Page 1 of 2 Z 10 Z abed NOU9 (99/L A@8) 96o-ZL -�joM s,aaauibuo jeuoissaload ay} ui suoissiwo ao saoAn aol apsuodsw lou si abeaogouy }o Aj!jedioiunW all'panssi si aleoilpao e aao}aq elep azo leue ao suoiloadsui lonpuoo lou op SHHa 10 saa (oldw3 'sluawaiinbei alels pue leaapa} uieliao Alsiles olaapao ui suoilnipsui buipuaj aiagl pue sawog }o saasupind of Asolinoo e se sigl saop SHHCI aq.L 'u�seIy }0 9lelS aq} ui paaalsibai aaauibua Ieuoissaloid luepuedepui ue (q anoge g ldea6eaed ui uanib suoileluasaadaa agl uodn Aluo paseq paleoilpoo Ienoadcly fluoglny 1-11129H sanssi (SHHG) saoina9S uewnH pue glleaH }o luawliedaa abeaogouy}o Alijedloiunw aql lenoaddy leuoilipuo0 }o swial Jeuoilipuo0 panoaddesi(j \, panoaddy 0/ area � ,� (q swooapa � y�Jo} panoaddy r IVAOdddV SHH(3 .9 Y / 9124 11c66 z',1313I'd `aaniM ajFie3 --- t'M'ok eo cloo 3n1 t ssaaPpy n —�`� � auolda�al `l�L; (3S\i'�N3 5 3 S (uaid }o aweN 'uoiloadsui sigl }o alep all uo Joa}}a ui suoiJelnbei pue 'saoueuipio 'sapoo 91215 PUB jeclioiunW ale glint aoueildwoo ui si walsAs [esodsip aaleMalseM ao/pue Alddns aaleM alis-uo all 'uoiloadsui PUB uoilebilsanui (w woal pue saki} abeaogouy }o Aj!padioiunW aql woal pauielgo uoiJe(wop aql uo paseq Jell (}iaan aagl.)n} I 'ulaaag paleoipui ainJonals }o adAl pue swooapaq to .iagwnu all ao} alenbape pue peuoiloun} 'a}es sl (ualsL S lesodsip jaleMalseM Ao/pue /\Iddns jaleM alis-uo aql legl smogs Jenoaddy Alijoglny glleaH sigl }o uoileEiilsanui AW Jell AI!AE)n I 'Molaq UMogs alep uoilepiIen aql }o se pue olaaaq Paxil}e leas (w Aq poilpeo sy NOLLifIM»03M1 9NV *Ilya 1-108h213 3"?I:! `30.1-331 '31IOLI MSM ONICIAM+d Mild ONIH33NION3 'S e �°�\�5�°: MUNICIPALITY OF ANCHORAGE (MOA) "G yo Health Authority Approval (HAA) °FP��L� ` CHECKLIST - FEBRUARY 1984 �'- ��� 343-4744 P P Legal Description: L10T moi- t3u�'LiL S A. WELL DAT& Well Classifidation .Yr►%_-)+y(k->yati If A, B, C, D.E.C. Approved (Y/N) r'l Well Log Present ®/N) Date Completed 10 -22o-'1 V Yield Z O QPA& Total Depth100-L6" Cased to 4D�� Depth of Grouting g' �a"gbl Static Water Level Pump Set At VK - Casing Height Above Ground 1Z Sanitary Seal on Casing 6%) y Electrical Wiring in Conduit (DN) Depression Around Wellhead (YQ SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot �boti� ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot Db ; On Adjoining Lots oa a- To Nearest Public Sewer Line P To Nearest Public Sewer Cleanout/Manhole To Nearest Sewer Service Line on Lot LS�� Water Sample Collected by S4 S Ln ; Date 10 `-C (D Water Sample Test Results 5AeT156�'��� Comments B. SEPTIC/HOLDING TANK DATA Date Installed � 0-4 `t,o Size 100 C� No. of Compartments Z Standpipes (9N) N/Air-tightCaps ON) N Foundation Cleanout/N) Depression over Tank (Y/@) �1 I Date Last Pumped Pumping/Maintenance Contact on File (Y/N) alp ; for r►1 Holding Tank High -Water Alarm (Y/N) K Temporary Holding Tank Permit (Y/N) SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water -Supply Well O'I L. _ To Building Foundation To Property Line IV t To Disposal Field To Water Main/Service Line C> To Stream, Pond, Lake or Major Drainage Course \ b0 Comments 72-026 (Rev. 7/88) Front Page 1 of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 1Sa'/�� Type of System Design �ef�s-ae x1 Date Installed 4 --cl o Length of Field Width of Field :S Cit Depth of Field c, Gravel Bed Thickness LO, Square Feet of Absortion Area 4S L'4 Statndpipes Present &N) Depression over Field (Y& Date of Last Adequacy Test N Results of Last Adequacy Test ►J �A— SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water -Supply Well \ nod k— To Property Line To Building Foundation \nTo Existing or Abandoned System on Lot _ l2\'t" ; On Adjoining Lots To Water Main/Service Line i r:>\ r To Cutback (if present) To Stream, Pond, Lake, or Major Drainage Course \ r> o 1-4— To Driveway, Parking Area, or Vehicle Storage Area 3 0 �- Comments D. LIFT STATION Date Installed Size in Gallons "Pump (fin" Level at High Water Alarm Tested for Meets MOA Electric Dimensions Manhole/Access (Y/N) "Pump Off" Level at ent (Y/N) _ Pumping Cycles during Adequacy Test. **Check Permitted Bedroom Rating Against HAA Request** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in eff inspection. & 5 ENGINe.KWNG 17034 gaggle Illnrer Loop Road N9, 294 Signed ---Eagle fiver, Al ROW 99tiZZ � c J ti Company Date MOA No. _ 02 asy Receipt No. �35z) Receipt No. Date of Payment �~ �°) — Waiver Fee: $ Amount: $ 17000 Date of Payment 72-026 (Rev. 7/88) Back Page 2 of 2 �4ate of this 4uf°'l, 5 ❑ PUBLIC WATER SYSTEM I.D.# I 1 I I I I I '16 PRIVATE WATER SYSTEM Name Phone No. Mailing Address 1��Pf(;7 1, (G et Cf57-7 City StateZip Code � DIE SAMPLE DATE: Mo. Day Year SAMPLE TYPE: R�-Routine ❑ Check Sample (for routine sample with lab ref. no. 1 ❑ Treated Water ❑ Special Purpose ❑ Untreated Water SAMPLE Time Collected NO. LOCATION Collected By 1 ►� rg g� I �: 4s 2 1M� 3 4 5 1 Fs si shows this Water SAMPLE to be: atisfy ctory nsatisfactory ❑ Sample too long in transit; sample should not b6over 30 hours old at examination to indicate reliable results. Please send new sample via special delivery mail. Date Received Time Received Analytical Method: Membrane Filter ` No. of colonies/100 ml. Lab Ref. No. Result* Analyst 90.4086 .Z M BACTERIOLOGICAL WATER ANALYSIS RECORD / READ INSTRUCTIONS Membrane Filter. Direct County Coliformn00 ml BEFORE Verification: LTB uuu COLLECTING SAMPLE Final Membrane Filter Results / CollformhOO ml Reported By= — Date —70 Time: lam% a.m. p.m. TNTC = Too Numberous To Count PART ONE OF TWO OB = Other Bacteria REMAINDER TO FOLLOW of J g4 LABORATORIES CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. 5633 B STREET E ANCHORAGE, ALASKA 99518 • TELEPHONE (907) 562-2343 FEDERAL TAX I.D. #92-0040440 ANALYSIS REPORT BY SAMPLE fox Work Order # 29020 Date Report Printed: OCT 10 90 @ 09:25 Client Sample ID:14 B5 MC14AHON #2 PWSID :UA Collected OCT 4 90 @ 18:45 his. Received OCT 5 90 @ 14:00 his. Preserved with :AS REQUIRED Client Name S & S ENGI14EERING Client Acct SNSENGP P.O.# NONE RECEIVED Req # Ordered By : R. SHAFER Analysis Completed :OCT 5 90 Send Reports to: Laboratory Supervis x HEN C. EDE 1)S & S ENGINEERING Released By I(,f— 2) Special / Instruct: Chemlab Ref #: 904086 Lab Smpl ID: 1 Matrix: WATER Allowable Parameter Tested Result Units Method Limits ----------------------------------------------------------------------------------------------------------- NITRATE-N 1.8 mg/l EPA 353.2 10 Sample ROUTINE SAMPLE. Remarks: SA14PLE COLLECTED BY RAY. 1 Tests Performed See Special Instructions Above UA=Unavailable ND= None Detected See Sample Remarks Above NA= Not Analyzed LT=Less Than, GT=Greater Than DF.�NDFVFryDF Ht! 2� 9 a o O y J E MUNICIPALITY OF ANCHORAGE \9 �W DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 NUMBER OF BEDROOMS REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for. processing. , 1. PROPERTYOWNER,/ 30ffN _ I� • ,26-5 S PHONE 4-513 - //-5 MAILING ADDRESS S A)Cq 9`3s�oZ Three ❑ Six PROPERTY RESIDENT (If different from above) PHONE /009,4K P1 -a -C -e 3 giq-s37L 2. BUYER PHONE ❑ PUBLIC UTILITY depth (attach log if available.) MAILING ADDRESS 3. LENDING 1 STITUTION !� SANK C PHONE L/4$lCO &-F 0 124 ,w G�C.G If system is over two (2) years old an adequacy tet is required MAILING ADDRESS_ S' by this Department. (Z- 13 944. NGld 4. REALTOR/AGENT PHONE ti MAILING ADDRESS( 5. LEGAL DESCRI TION E0 i 5 Lo C. - S� ly% !,4rfo v Sd Z Na 1W STREET LOCATION owwq-K A- r4z� 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS SINGLE FAMILY ❑ One ❑ Four ❑ Other ❑ Two ❑ Five ❑ MULTIPLE FAMILY Three ❑ Six 7. WATER SUPPLY - Q INDIVIDUAL* *.ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE SYSTEM ,DISPOSAL s� INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date -1 If system is over two (2) years old an adequacy tet is required ❑ PUBLIC UTILITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONL. INSPECTION APPOINTMENTS DATE RECEIVED TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE >' SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE 9� THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PEGR-�MIT NUMBER /10�� DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ;'�eINDIVIDUAUON -SITE ❑PUBLIC UTILITY Connection Verified PEQJMITNUMBE R DATT(.FF INS ALI ED d/ / INSTAL ER `�b Septic Tank or ❑Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING - D TYPE 7 -fly JG /t loDl) M , FACTUR�R )r -e- L, TOTAL PTIONAREki 0 MATERIAL 4. DISTANCES WELLTO: Se t' /Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS Ll ` 1 O UW 6--APPROVED FOR BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE BY (Title)( LEGAL DESCRIPTION 72-010 (Rev. 3/78)