Loading...
HomeMy WebLinkAboutNORTH WOODS UNIT 4 BLK 17 LT 7MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231261 Work Type: Septic Upgrade Tax Code Number: 05106448000 Site Legal Address: NORTH WOODS UNIT 4 BLK 17 LT 7 G:1460 Site Mailing Address: 23409 BLUE SKIES DR, Chugiak Owner: COX CHRISTOPHER Design Engineer: HDL ENGINEERING CONSULTANTS This permit is for the construction of: Effective Date Expiration Date Lot Size in Sq Ft Total Bedrooms: �ncnt S i° U � J t)Ppai-trnent 9/19/2023 9/18/2024 29081 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: ' 5.5 LA -t-0 R -D L. Issued By: 1 L Date: Date: Z- 4 MUNICIPALITY OF ANCHORAGE Development Services Department - Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 05106448000 Property owner(s) Christopher Cox Mailing address Site address 23409 Blue Skies Dr. , Chugiak, AK 99567 Day phone 907-687-4236 Legal description (Sub'd., Block & Lot) North Woods Sub Unit 4, Block 17 , Lot 7 Legal description (Township, Range & Section) Lot Size 29,081 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field 0 Initial ❑ Single Family (SF) El ADU) Septic Tank 0 Upgrade El(w/wo (D) El Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. )�v4z,k / Mark Fondren, PE (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: 00236I� Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc ANCHORAGE, ALASKA SCATTERED SITES - SITE 4 NORTH WOODS UNIT 4 BLOCK 17 LOT 7 ISSUED FOR REVIEW PLAN SET NUMBER: AKA-22-ANC ANTHC PROJECT NUMBER: AKAC3K-1276SSS RUSSIA A L E U T I A N OF BRISTOL BAY CO O K I NLE T NORTON SOUND NOME KOTZEBUE BARROW JUNEAU FAIRBANKS CANADA ARCTIC OCEAN GULF ALASKA I S L A N D S BERING SEA CHUKCHI SEA KODIAK BETHEL UNALASKA Su s i tna Koyu k u k Yukon Yuk o n Kus k o k w i m Ri v er Riv er Rive r River Tanana R i v e r Rive r Kobuk Col vi l l e R i ver Co p p e r River River ST. LAWRENCE ISLAND ST. MATTHEW ISLAND NUNIVAK ISLAND PRIBILOF ISLANDS SEC 27, T13N, R3W, SEWARD MERIDIAN ANCHORAGE TOTAL SHEETSOF USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\General\ANC-G-STGENL-4.dwg LAYOUT: COVER PRINTED: 9/15/2023 3:19:06 PM 1 15 4500 DIPLOMACY DRIVE ANCHORAGE, ALASKA, 99508-3440 PHONE: (907) 729-3600 FAX: (907) 729-4090 http://www.dehe.org A L A S K A N A T I V E TRIBAL HEALTH CONSORTIUM DIVISION OF ENVIRONMENTAL HEALTH AND ENGINEERING SHEET LIST TABLE G-001 GENERAL LEGEND G-002 GENERAL NOTES & DESIGN CRITERIA G-003 DESIGN SPECIFICATIONS G-004 DESIGN SPECIFICATIONS G-005 DESIGN SPECIFICATIONS C-001 CIVIL LEGEND C-101 SITE PLAN C-102 PROFILE C-301 SECTION SSSD-301 SEWER SERVICE AND CLEANOUT - ABS PIPE SSSD-400 SEWER SERVICE LINE TRENCH SSSD-512 IM-1060 - 1000 GALLON SEPTIC TANK - ABS PIPING SSSD-567 ANCHORAGE SEPTIC TANK Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231261, Curtis Townsend, 09/19/23 GENERAL NOTES: THESE DRAWINGS HAVE BEEN DEVELOPED FOR CONSTRUCTION BY CONSTRUCTION CONTRACT METHODOLOGY. CONSTRUCTION SPECIFICATIONS HAVE ALSO BEEN DEVELOPED SPECIFICALLY FOR THIS PROJECT. TOGETHER, THE DRAWINGS AND CONSTRUCTION SPECIFICATIONS CONSTITUTE A COMPLETE AND INSEPARABLE SET OF CONSTRUCTION DOCUMENTS, INCLUDING ALL NECESSARY CONSTRUCTION AND MATERIALS SPECIFICATIONS TO ENSURE THE PROJECT AS CONSTRUCTED MEETS THE DESIGN INTENT. ANY CHANGES TO CONSTRUCTION METHODS OR MATERIALS SHALL BE APPROVED IN ADVANCE BY THE RESPONSIBLE REGISTERED PROFESSIONAL. VICINITY MAP SCALE: 1" = 2640' ABBREVIATIONS ABS ACRYLONITRILE BUTADIENE STYRENE ADEC ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION ALUM ALUMINUM ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APPRO X APPROXIMATE ARV AIR RELEASE VALVE AS ASPHALT AVEC ALASKA VILLAGE ELECTRIC COOPERATIVE AVG AVERAGE AWWA AMERICAN WATER WORKS ASSOCIATION BH BORE HOLE BLDG BUILDING BMP BEST MANAGEMENT PRACTICE BOH BOTTOM OF HOLE BTU BRITISH THERMAL UNITS CFM CUBIC FEET PER MINUTE CL CENTERLINE CO CLEANOUT CONC CONCRETE CMP CORRUGATED METAL PIPE DCCED DEPARTMENT OF COMMERCE AND ECONOMIC DEVELOPMENT DIA DIAMETER DI DUCTILE IRON DIST DISTANCE DWV DRAIN WASTE VENT EG EXISTING GROUND/GRADE ELEC ELECTRIC ELEV ELEVATION FF FINISHED FLOOR FG FINISHED GROUND/GRADE FLG FLANGE FM FORCE MAIN FPS FEET PER SECOND FPT FEMALE PIPE THREAD GA GAUGE GALV GALVANIZED GPD GALLONS PER DAY GPM GALLONS PER MINUTE HDPE HIGH DENSITY POLYETHYLENE HORZ HORIZONTAL HP HORSEPOWER HUD DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT HWL HIGH WATER LEVEL ID INSIDE DIAMETER I/I INFILTRATION/INFLOW INV INVERT IPS IRON PIPE SIZE LB POUNDS LF LINEAR FEET LPS LOW PRESSURE SEWER LPSS LOW PRESSURE SEWER SERVICE MAX MAXIMUM MH MANHOLE MIN MINIMUM MLLW MEAN LOWER LOW WATER MPT MALE PIPE THREAD NFS NON FROST SUSCEPTIBLE NPSH NET POSITIVE SUCTION HEAD NSF NATIONAL SANITATION FOUNDATION NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OSHA OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION PE POLYETHYLENE PERC PERCOLATION PEX CROSS-LINKED POLYETHYLENE PP POWER POLE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PERCOLATION TEST PVC POLYVINYL CHLORIDE REPS RESIDENTIAL EFFLUENT PUMPING STATION ROW RIGHT OF WAY SDR STANDARD DIMENSIONING RATIO SL SLOPE SS SEWER SERVICES OR STAINLESS STEEL STA STATION SUBD SUBDIVISION SWPPP STORM WATER POLLUTION PREVENTION PLAN SWT SWEAT TDH TOTAL DYNAMIC HEAD THD THREADED TYP TYPICAL UHMW ULTRA HIGH MOLECULAR WEIGHT VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE WST WATER STORAGE TANK WTP WATER TREATMENT PLANT SECTION 11, T11N, R3W, SEWARD MERIDIAN, ALASKA, USGS QUAD: ANCHORAGE A-8 PROJECT LOCATION GLE N N HIG H W A Y LOOP B I R C H W O O D OLD G L E N N H I G H W A Y GENERAL SYMBOLS 0 1" 2" X X-XXX X X-XXX X-XXX X X 0 10000'20000' HORZ. SCALE VERT. SCALE VIEW TITLE X XX"-XX' XX"-XX' VIEW TITLEX XX"-XX' DRAWING TITLE OR SECTION TITLE DRAWING TITLE OR SECTION TITLE WITH VERTICAL AND HORIZONTAL SCALE SECTION INDICATOR DRAWING OR PHOTO/IMAGE ELEVATION INDICATOR CALL OUT BUBBLE ARCHITECTURAL GRAPHIC SCALE ENGINEERING GRAPHIC SCALE BREAK LINE KEY NOTE INDICATOR (REFERS TO NOTE ON SAME SHEET) REVISION INDICATOR # MATCH LINE, SEE X-XXX MATCH LINE VIEW NUMBER VIEW NUMBER SHEET NUMBER SHEET NUMBER SHEET NUMBER VIEW NUMBER VIEW NUMBER VIEW NUMBER SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\General\ANC-G-STGENL-4.dwg LAYOUT: GENERAL LEGEND PRINTED: 9/15/2023 3:20:03 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W G-001 1 5 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC GENERAL LEGEND 15 2 SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\General\ANC-G-STGENL-4.dwg LAYOUT: GENERAL NOTES & DESIGN_CRITERIA PRINTED: 9/15/2023 3:19:35 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W G-002 2 5 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC GENERAL NOTES & DESIGN CRITERIA 15 3 1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THESE PLANS AND THE BIDDING AND CONTRACT DOCUMENTS TITLED "ANCHORAGE, ALASKA SCATTERED SITES - SITE 4 NORTH WOODS UNIT 4 BLOCK 17 LOT 7" DATED AUGUST 2023. 2. SCOPE OF WORK a. PROVIDE ALL LABOR, EQUIPMENT, MATERIALS, AND SUPERVISION REQUIRED FOR CONSTRUCTION OF A COMPLETE ON-SITE SANITARY SEWER SYSTEM INCLUDING SEWER PIPING, SEPTIC TANK, AND SUBSURFACE DISPOSAL SYSTEM AS SHOWN ON THE PLANS, THESE SPECIFICATIONS, AND IN ACCORDANCE WITH MUNICIPALITY OF ANCHORAGE (MOA) AND/OR ADEC REQUIREMENTS. b. COMPLETELY REMOVE AND DISPOSE OF EXISTING SEPTIC TANK. c. REMOVE PORTIONS OF EXISTING LEACH FIELD IN VICINITY OF PROPOSED SYSTEM AS SPECIFIED IN DESIGN CRITERIA AND ON PLANS. d. MARK UP CONSTRUCTION PLANS TO REFLECT FIELD CHANGES, ELEVATIONS, AND SWING-TIES OF CONSTRUCTION. SUBMIT "RED LINE" DRAWINGS TO ENGINEER AT COMPLETION OF THE PROJECT. 3. ALL WORK SHOWN IN THIS PLAN SET SHALL BE INCLUDED IN THE BASE BID LUMP SUM ITEM FOR "CONSTRUCT ON-SITE SANITARY SEWER SYSTEM," UNLESS NOTED OTHERWISE, AND SHALL INCLUDE ALL LABOR, EQUIPMENT, MATERIAL, AND SUPERVISION REQUIRED TO PROVIDE A COMPLETE AND WORKING SYSTEM AND RESTORE THE SITE TO ITS PRE-CONSTRUCTION CONDITION. 4. THESE PLANS ARE BASED ON TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY ANTHC IN SUMMER 2022. THE CONTRACTOR SHALL VERIFY SITE CONDITIONS, DIMENSIONS, AND DETAILS PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES AND/OR UNKNOWN CONDITIONS WHICH AFFECT THE PROJECT ARE FOUND, THE CONTRACTOR SHALL NOTIFY ANTHC AND THE PROJECT ENGINEER. THE CONTRACTOR MAY BE REQUIRED TO PROVIDE MINOR LAYOUT CHANGES IN THE FIELD BASED ON ACTUAL SITE CONDITIONS. VERIFY ALL CHANGES WITH ANTHC AND THE PROJECT ENGINEER PRIOR TO PROCEEDING 5. A GEOTECHNICAL INVESTIGATION WAS PERFORMED ON JUNE 21, 2023 BY HDL. GROUNDWATER LEVELS INDICATED ON THE PLANS MAY VARY DEPENDING ON TIME OF YEAR. THE CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING NECESSARY TO INSTALL IMPROVEMENTS IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AT NO ADDITIONAL COST TO THE OWNER. 6. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 7. NOT ALL UTILITIES MAY BE SHOWN ON THE PLANS. CONTRACTOR SHALL FIELD VERIFY EXISTING UTILITIES BEFORE CONSTRUCTION. CONTRACTOR SHALL PROTECT UTILITIES AT ALL TIMES DURING CONSTRUCTION, AND REPAIR DAMAGES IN ACCORDANCE WITH THE RESPECTIVE UTILITY COMPANIES REQUIREMENTS. 8. CONTRACTOR SHALL INSTALL ALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS, AND INSTALLATION DRAWINGS, UNLESS INDICATED OTHERWISE. 9. CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, STATE AND FEDERAL OCCUPATIONAL SAFETY & HEALTH REGULATIONS, U.S. ENVIRONMENTAL PROTECTION AGENCY, ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION, AND ALL OTHER FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS PERTAINING TO THIS PROJECT. ANY WORK PERFORMED BY THE CONTRACTOR CONTRARY TO SUCH LAWS OR REGULATIONS SHALL BE MET AT THE CONTRACTOR'S SOLE RISK AND EXPENSE. 10. WORK SHALL BE PERFORMED WITH SKILLED CRAFTSMEN SPECIALIZING IN THE REQUIRED WORK. INSTALL ALL MATERIALS IN A NEAT, ORDERLY, AND SECURE FASHION, AS REQUIRED BY THE CONTRACT DOCUMENTS AND COMMONLY RECOGNIZED STANDARDS OF GOOD WORKMANSHIP. 11. ALL EXCAVATIONS SHALL BE SLOPED AND SHORED AS REQUIRED FOR SAFETY OF PERSONNEL AND TO ENSURE THAT EXISTING STRUCTURES, UTILITY POLES, AND UNDERGROUND UTILITIES ARE NOT COMPROMISED. UTILIZE PORTABLE TRENCH SHIELDS OR OTHER SUPPORT SYSTEMS IN COMPLIANCE WITH RELEVANT OSHA REGULATIONS. 12. CONTRACTOR SHALL PROTECT ALL MONUMENTS AND PROPERTY CORNERS. DAMAGED/MOVED MONUMENTS AND CORNERS, WHETHER OR NOT THEY ARE SHOWN ON THE DRAWINGS, SHALL BE PROPERLY SURVEYED AND REPLACED IN THEIR PRECONSTRUCTION CONDITION. SUBMIT SURVEY FIELD BOOK TO PROJECT ENGINEER AFTER CONSTRUCTION IF ANY MONUMENTS ARE IMPACTED. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR THE OVERALL CARE OF PROPERTY USED TO STAGE MATERIALS AND EQUIPMENT DURING CONSTRUCTION. FUEL, OIL, HYDRAULIC FLUID, AND OTHER PETROLEUM OR COMBUSTIBLE PRODUCTS SHALL BE STORED AND MAINTAINED AT A LOCATION ACCEPTABLE TO THE OWNER'S REPRESENTATIVE. 14. ALL EQUIPMENT OWNED BY THE CONTRACTOR SHALL BE KEPT IN GOOD REPAIR AT ALL TIMES. ALL POWERED EQUIPMENT SHALL BE INSPECTED BEFORE AND AFTER EACH USE FOR ANY FUEL, HYDRAULIC OIL, OR COOLANT LEAKS. THE USE OF ANY POWERED EQUIPMENT WITH KNOWN LEAKS IS PROHIBITED. SITE CLEAN-UP OF ANY ACCIDENTAL PETROLEUM LEAKS OR SPILLS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REMEDIATED IMMEDIATELY UPON DISCOVERY. ANY SPILL, REGARDLESS OF SIZE, MUST BE REPORTED TO THE OWNER'S REPRESENTATIVE AS SOON AS PRACTICAL. IN ADDITION, CONTRACTOR SHALL COMPLY WITH ALL ADEC REQUIREMENTS IN 18 AAC 75. 15. REFUELING OR OTHER FLUID HANDLING ACTIVITIES MAY HAVE SPECIAL RESTRICTIONS IN SENSITIVE AREAS, SUCH AS WITHIN 100 FEET OF DRINKING WATER WELLS. ACCEPTABLE LOCATIONS FOR SUCH ACTIVITIES SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE. AN ADEQUATE SUPPLY OF ABSORBENT PADS SHALL BE KEPT ON SITE TO FACILITATE INITIAL REMEDIATION OF SMALL PETROLEUM SPILLS. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK WITH ANY OTHER CONTRACTORS IN THE VICINITY, HIS SUBCONTRACTORS, THE OWNER, AND STATE AND FEDERAL AUTHORITIES. 17. ALL ITEMS SHOWN ARE NEW UNLESS SPECIFICALLY INDICATED AS EXISTING. INSTALL ALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS, AND INSTALLATION DRAWINGS UNLESS INDICATED OTHERWISE. SEPTIC SYSTEM GENERAL NOTES 1. CONTRACTOR SHALL ABIDE BY MUNICIPALITY OF ANCHORAGE WASTEWATER REGULATIONS, AMC 15.65. 2. CONTRACTOR SHALL VERIFY THAT ALL SEPARATION DISTANCES FOR SEPTIC TANK AND DRAINFIELD LOCATIONS STATED IN PLANS AND SPECS HAVE BEEN MET. 3. CONTRACTOR SHALL FURNISH ALL ON-SITE SEPTIC RELATED SUBMITTALS FOR APPROVAL PRIOR TO BEGINNING WORK. 4. CONTRACTOR SHALL SEQUENCE HIS CONSTRUCTION TO MAINTAIN WASTEWATER SERVICE TO THE BUILDINGS FOR THE GREATEST EXTENT POSSIBLE. CONTRACTOR WILL BE ALLOWED A SINGLE, EIGHT (8) HOUR WINDOW IN WHICH TO MAKE FINAL CONNECTION BETWEEN THE BUILDING AND EXISTING SEWER CONVEYANCE PIPING. 5. HDL WILL APPLY FOR MOA WASTEWATER PERMIT AND WILL APPLY FOR APPROVAL OF THE SYSTEM FROM MOA AFTER CONSTRUCTION. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH MOA AND/OR ADEC REGULATIONS. 6. WITHIN 5 WORKING DAYS OF COMPLETION OF THE PROJECT THE CONTRACTOR SHALL PROVIDE A SET OF RED-LINED DRAWINGS TO THE ENGINEER. DRAWINGS SHALL SHOW AS-BUILT MEASUREMENTS OF THE COMPLETE SYSTEM INSTALLATION. ALL SWING-TIE MEASUREMENTS SHALL BE TAKEN TO THE NEAREST 1/10 FOOT. TAPE SHALL BE HELD TAUT TO PROVIDE AS ACCURATE A MEASUREMENT AS POSSIBLE. 7. VERTICAL ELEVATION MEASUREMENTS SHALL BE TAKEN BASED ON THE FINISHED FLOOR OF THE BUILDING AT THE FOLLOWING POINTS, AT A MINIMUM: a. INLET AND OUTLET OF TANKS; TOP OF PIPE; EACH CLEANOUT b. BEGINNING; MIDPOINT; AND END OF EACH DRAINFIELD AT: ELEVATION OF BOTTOM OF DRAINFIELD BEDS, ELEVATION OF BOTTOM OF LATERAL PIPES, ELEVATION OF FINISHED GRADE 8. CONTRACTOR SHALL SUBMIT SEPTIC SYSTEM DOCUMENTATION TO THE ENGINEER IN ACCORDANCE WITH SPECIFICATION SECTION 01 78 39 AND AMC 15.65. 9. SEWER ROCK AND FILTER SAND MUST MEET MUNICIPALITY OF ANCHORAGE SPECIFICATIONS. 10. THE SEWER ROCK MUST BE RAKED LOOSE AND NOT COMPACTED BY EQUIPMENT. PROJECT RESTORATION NOTES 1. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO PRE-CONSTRUCTION CONDITION OR BETTER. CONSTRUCTION DEBRIS SHALL BE REMOVED FROM THE PROJECT AREA AND DISPOSED OF AS DIRECTED BY THE OWNER. CONTRACTOR SHALL EXERCISE DUE CARE TO AVOID DISTURBING AREAS OUTSIDE THE WORK LIMITS. 2. DISTURBED AREAS OUTSIDE TRAVELED WAYS SHALL BE STABILIZED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 3. ALL DISTURBED AREAS OR SLOPES SHALL BE RE-GRADED, COMPACTED, AND SEEDED AS DETAILED IN THE SPECIFICATIONS. 4. THE CONSTRUCTION SITE, STAGING AREAS, STORAGE AREAS, AND MOBILIZATION AND DEMOBILIZATION ROUTES SHALL BE RESTORED TO THEIR ORIGINAL CONDITIONS PRIOR TO CONSTRUCTION ACTIVITIES. ANY LEFTOVER MATERIALS SHALL BE REMOVED FROM THE SITE. ALL EXCAVATED MATERIAL SHALL BE USED AS BACKFILL OR REMOVED FROM THE SITE AND THE SURFACE PROFILE SHALL BE GRADED AS SHOWN IN THE PLANS. GENERAL NOTES 1. STATE OF ALASKA ADEC ONSITE WASTEWATER SYSTEM INSTALLERS MANUAL, JANUARY 2016. 2. ADEC WASTEWATER DISPOSAL REGULATIONS 18 AAC 72, NOVEMBER 2017. 3. MUNICIPALITY OF ANCHORAGE WASTEWATER REGULATIONS, AMC 15.65. 4. MUNICIPALITY OF ANCHORAGE STANDARD SPECS 2023 (MASS) REFERENCES DESIGN CRITERIA 1. SOIL ABSORPTION SYSTEM · 4 BEDROOM HOUSE. DESIGN FLOW RATE: 150 GAL/DAY/BEDROOM. TOTAL DESIGN FLOW: 600 GAL/DAY · GEOTECH MEMO SUBMITTED SEPARATELY WITH PLANS INCLUDES HDL TEST PIT LOG & PERC TEST INFORMATION · HDL TEST PIT TP-01 EXCAVATED ON JUNE 21, 2023 (SEE SHEET C-101 FOR LOCATION). SOIL FROM 4.0 - 12 FT BELOW GROUND SURFACE (BGS) CLASSIFIED SM; TARGET RECEIVING SOILS AT 6 FT BGS. PERCOLATION TEST CONDUCTED IN BENCH NEAR TP-01 AT 5 FT BGS HAD PERCOLATION RATE OF APPROXIMATELY 1.6 MIN/IN. · BASED ON PREVIOUS DESIGN FOR SITE SOIL ABSORPTION SYSTEM & ADJACENT PROPERTIES - WE PROPOSE TO USE MORE CONSERVATIVE PERCOLATION RATE. RECORD INFORMATION PERC RATES ARE IN 6 - 15 MIN/IN RANGE (SEE GEOTECH MEMO). · DURING EXCAVATION NO GROUNDWATER WAS OBSERVED IN TP-01 TO 13.3 FT; ON JUNE 29, 2023 GROUNDWATER WAS NOT OBSERVED IN HDL TP-01 GROUNDWATER MONITOR TUBE. · SEASONAL HIGH GROUNDWATER ESTIMATED AT 12.3 FT BGS BASED ON ADJUSTMENT FACTOR OF 1 FT FOR JUNE (TABLE 1, AMC 15.65). · BED SYSTEM APPLICATION RATE: 0.5 GAL/SQ FT (TABLE 2, AMC 15.65) · BED SYSTEM ABSORPTION AREA REQUIRED: (4 BEDROOMS * 150 GAL/BEDROOM/DAY) / (0.5 GAL/SQ FT) = 1200 SQ FT · BASED ON SITE AREA AVAILABLE - 30' WIDE BED REQUIRES LENGTH = [ SQ FT / (24 FT)] = 40 FT · A 30'X40' BED SOIL ABSORPTION SYSTEM (SAS) IS PROPOSED · WATER SERVICE LINE ONSITE WAS LOCATED 10.8' AWAY FROM NORTHWEST MONITOR TUBE OF BED SAS. PROPOSED SAS TO BE INSTALLED APPROXIMATELY 7 FT SOUTH OF EXISTING SYSTEM TO BE FURTHER FROM WATER SERVICE LINE. · REMOVE EXISTING BED SAS IN THE AREA OF PROPOSED SAS. BOTTOM OF THE PROPOSED SAS WILL BE APPROXIMATELY 1 FT LOWER THAN BOTTOM OF EXISTING SAS. · RECEIVING SOILS OF PROPOSED SAS SHALL BE FREE FROM SIGNS OF EFFLUENT PLUGGING AND MAJOR STAINING. AT THE DIRECTION OF ENGINEER, ADDITIONAL EXCAVATION AND IMPORTED MOA FILTER SAND MAY BE REQUIRED IF SAS RECEIVING SOILS SHOW SIGNIFICANT SIGNS OF EFFLUENT INFLUENCE GREATER THAN 1 FT BELOW EXISTING SAS. IF ADDITIONAL EXCAVATION AND/OR FILTER SAND IS REQUIRED, CONTRACTOR IS TO BE COMPENSATED ON A T&M BASIS BY ANTHC. · EXISTING SEWER ROCK TO BE HAULED OFF SITE DUE TO LACK OF DISPOSAL AREA ON SITE 2. SEPTIC TANK · MINIMUM SEPTIC TANK SIZE FOR 4-BEDROOM HOME IS 1250 GALLONS · PROPOSE TO INSTALL ANCHORAGE TANK 1500 GALLON EPOXY COATED STEEL TANK OR EQUAL · SINCE WATER TABLE WAS NOT OBSERVED TO 13.3 FT, BUOYANCY RESTRAINTS ARE NOT INCLUDED IN DESIGN SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\General\ANC-G-STGENL-4.dwg LAYOUT: DESIGN SPECS 1 PRINTED: 9/15/2023 3:20:34 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W G-003 3 5 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC DESIGN SPECIFICATIONS 15 4 ON-SITE SEPTIC SYSTEM PART 1 - SUBMITTALS A. THE CONTRACTOR SHALL SUPPLY MATERIAL, PRODUCT DATA, SHOP DRAWINGS, OR TECHNICAL DATA SHEETS FOR THE FOLLOWING ITEMS TO DEMONSTRATE COMPLIANCE WITH THE SPECIFICATIONS: 1. BEDDING MATERIAL 2. SEWER ROCK 3. SEED 4. TOPSOIL 5. GEOTEXTILE FABRIC 6. PIPE AND FITTINGS 7. SEPTIC TANK 8. RIGID INSULATION B. CONTRACTOR SHALL PROVIDE “CERTIFIED SEED” REPORT, OR FOUR SIGNED COPIES OF A REPORT CERTIFYING THAT EACH LOT OF SEED HAS BEEN TESTED BY AN APPROVED LABORATORY WITHIN 9 MONTHS OF DATE OF APPLICATION. INCLUDE NAME AND ADDRESS OF LAB, DATE OF TEST, LOT NUMBER FOR EACH KIND OF SEED, AND RESULTS OF TEST AS TO NAME, PERCENTAGES OF PURITY AND GERMINATION, AND PERCENTAGE OF WEED CONTENT FOR EACH KIND OF SEED FURNISHED. C. THE CONTRACTOR SHALL SUBMIT INSTALLATION RECORD DRAWINGS TO ENGINEER PROMPTLY AFTER COMPLETION OF THE ON-SITE SANITARY SEWER SYSTEM. ENGINEER WILL SUBMIT DRAWINGS TO MOA FOR APPROVAL. PART 2 - MATERIALS USE MATERIALS THAT CONFORM TO ADEC REQUIREMENTS AND THE FOLLOWING: A. BEDDING MATERIAL USE CLEAN AGGREGATE FREE OF FRIABLE MATERIALS AND DEBRIS; MEETING THE FOLLOWING GRADATION FOR BEDDING MATERIAL WHERE SHOWN ON THE PLANS. SIEVE DESIGNATION % PASSING 1”100 3/4”80-100 #4 20-75 #8 12-60 #30 2-30 #200 *0-6 B. SEWER ROCK USE MATERIAL MEETING THE FOLLOWING GRADATION WHERE SHOWN ON THE PLANS. SIEVE DESIGNATION % PASSING 2”100 1 12"95-100 1"0-100 3/4"0-10 1/2"0-5 #200 0-1 C. DRAIN FIELD GEOTEXTILE NON-WOVEN FABRIC NON-WOVEN FILTER FABRIC SHALL HAVE THE FOLLOWING CHARACTERISTICS: 1. MINIMUM PERMITTIVITY (ASTM D4491) = 0.50 SEC -1 2. MAXIMUM APPARENT OPENING SIZE (ASTM D4751) = 0.20 - 0.21 MM (US SIEVE #70) D. MOA FILTER SAND USE MATERIAL MEETING THE FOLLOWING GRADATION FOR MOA FILTER SAND WHERE SHOWN ON THE PLANS. SIEVE DESIGNATION % PASSING 3/8”100 #4 95-100 #100 0-4 E. PIPE AND FITTINGS 1. ALL PIPING SHALL BE IN ACCORDANCE WITH CONSTRUCTION DOCUMENTS CONFORMING TO THE SIZE AND CLASS SHOWN AND SPECIFIED HEREIN. 2. POLYVINYL-CHLORIDE (PVC) SEWER PIPE SHALL CONFORM TO ASTM D3034 (TYPE PSM POLY VINYL CHLORIDE (PVC) SEWER PIPE AND FITTINGS, SPEC FOR), SDR-35. FILLED PVC OR STYRENE RUBBER PIPE WILL NOT BE ALLOWED. JOINTS FOR PVC SEWER PIPE SHALL CONFORM TO ASTM D3212 (JOINTS FOR DRAIN AND SEWER PIPES USING FLEXIBLE ELASTOMERIC SEALS). SCHEDULE 40 AND SCHEDULE 80 PVC SHALL CONFORM TO THE REQUIREMENTS OF ASTM D1785 3. ACRYLONITRILE-BUTADIENE-STYRENE (ABS) SEWER PIPE SHALL CONFORM TO ASTM F628, SCHEDULE 40. F. RIGID INSULATION BOARD 1. RIGID BOARD INSULATION: INSULATION SHALL BE 2-INCH THICK RIGID BOARD INSULATION FURNISHED IN MINIMUM 2-FOOT WIDE SHEETS AND SHALL HAVE THE FOLLOWING MINIMUM REQUIRED PHYSICAL PROPERTIES. a. COMPRESSIVE STRENGTH (ASTM D1621): 40 PSI (5% DEFORMATION) b. THERMAL CONDUCTIVITY (ASTM C177): K-VALUE =0.20 @ 25 DEGREES FAHRENHEIT c. WATER ABSORPTION (ASTM D2842): 1% (BY VOLUME @ 96 HRS) d. APPROVED PRODUCTS: DOW HI-40 OR EQUAL. G. TOPSOIL 1. TOPSOIL SHALL CONSIST OF A NATURAL FRIABLE SURFACE SOIL WITHOUT ADMIXTURES OF UNDESIRABLE SUBSOIL, REFUSE, OR FOREIGN MATERIALS AND SHALL BE REPRESENTATIVE OF NATURALLY AVAILABLE SOILS AT OR NEAR THE PROJECT SITE. THE MATERIAL SHALL BE FREE FROM ROOTS, CLODS, HARD CLAY, ROCKS GREATER THAN 1 INCHES IN DIAMETER, NOXIOUS WEEDS, TALL GRASS, BRUSH, STICKS, STUBBLE OR OTHER LITTER, AND SHALL BE FREE DRAINING AND NON-TOXIC. USE TOPSOIL MEETING THE FOLLOWING GRADING REQUIREMENTS SPECIFIED BELOW: SIEVE DESIGNATION % PASSING 1”100 1/2"- #4 75-100 #16 50-95 #200 20-80 H. SEED 1. MUST MEET THE APPLICABLE REQUIREMENTS OF THE STATE OF ALASKA SEED REGULATIONS, 11 AAC 34, ARTICLES 1 AND 4. 2. THE FOLLOWING IS MASS SCHEDULE A MOWABLE SEED MIX. SPECIES PROPORTION MIN. % SPROUTABLE* BY WEIGHT ANNUAL RYEGRASS 5%77% (LOLIUM MULTIFLORUM) KENTUCKY BLUEGRASS KENAI 30%77% (POA PRATENSIS ‘KENAI’) ALENE 25%77% (POA PRATENSIS) BOREAL FESCUE 40%77% (FESTUCA RUBRA ‘BOREAL’) *% SPROUTABLE IS PRODUCT OF %PURITY AND %GERMINATION. 3. ACCEPTABLE MANUFACTURES INCLUDE THE FOLLOWING a. ALASKA MILL AND FEED b. POLAR SUPPLY COMPANY c. OR APPROVED EQUAL APPROVED SUBSTITUTION I. SEPTIC TANK 1. SEPTIC TANKS SHALL BE STEEL OR HDPE PLUS FITTINGS AND FIXTURES AS NECESSARY. THE TANKS SHALL BE OF CAPACITY AS INDICATED ON THE DRAWINGS AND SHALL MEET ALL REQUIREMENTS OF THE MOA AND/OR ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION (ADEC). AS SUCH, THE TANK SHALL HAVE TWO COMPARTMENTS WITH 24" DIAMETER MANHOLE OPENINGS, AND WATER TIGHT RISER SYSTEMS. ACCEPTABLE MANUFACTURES ARE LISTED BELOW. a. GREER b. ANCHORAGE TANK c. OR, APPROVED EQUAL 2. ALL TANKS SHALL COMPLY WITH THE UNIFORM PLUMBING CODE AND WITH IAPMO IGC 262-2013 SPECIFICATION FOR CORRUGATED THERMOPLASTIC TANKS. 3. ALL TANKS SHALL HAVE SUFFICIENT STRUCTURAL INTEGRITY TO WITHSTAND BEING PUMPED DRY WITHOUT INCURRING STRUCTURAL DEFORMATION (I.E. RIB COLLAPSE). 4. ALL RISERS SHALL BE WATERTIGHT, AVAILABLE IN 6-INCH OR 12-INCH INCREMENTS AND BE ABLE TO EXTEND TO GRADE FROM THE MAXIMUM BURIAL DEPTH. A GASKET SHALL BE USED IN TANK-TO-RISER AND RISER-TO-RISER CONNECTIONS. RISER COVERS SHALL BE LOCKABLE. 5. THE INLET INVERT ELEVATION TO THE FIRST COMPARTMENT SHALL BE AT LEAST 2 INCHES ABOVE THE LIQUID SURFACE. IN EACH SEPTIC TANK COMPARTMENT, THE INLET TEE, ELBOW, OR BAFFLE SHALL EXTEND A MINIMUM OF 20-25% OF THE LIQUID DEPTH IN INCHES BELOW THE LIQUID SURFACE, WHILE THE OUTLET TEE, ELBOW, OR BAFFLE FROM EACH COMPARTMENT SHALL EXTEND BELOW THE LIQUID LEVEL TO A DEPTH EQUIVALENT TO APPROXIMATELY 35% OF THE LIQUID DEPTH. INLET AND OUTLET TEES OR BAFFLES AND CONNECTIONS PROVIDED WITH THE POLYETHYLENE TANKS SHALL BE 4-INCH DIAMETER PIPE. INLET INVERT SHALL BE AT LEAST 2 INCHES ABOVE THE OUTLET INVERT. THE INLET AND OUTLETS OF THE TANKS SHALL BE GASKETED TO PROVIDE A LEAK-PROOF SEAL BETWEEN THE TANK AND 4-INCH INLET AND OUTLET PIPING. 6. ENTIRE STEEL TANK SURFACES, INSIDE AND OUT, SHALL BE COATED WITH MUNICIPALITY OF ANCHORAGE APPROVED COATING. 7. THE CONTRACTOR SHALL FURNISH SHOP DRAWINGS AND TECHNICAL DATA SHEETS TO THE ENGINEER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. THE SUBMITTALS SHALL CLEARLY SPECIFY THE MATERIALS OF CONSTRUCTION, EQUIPMENT COMPATIBILITY, AND SHOP DRAWINGS FOR THE UNIQUE PACKAGE BEING SUPPLIED. SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\General\ANC-G-STGENL-4.dwg LAYOUT: DESIGN SPECS 2 PRINTED: 9/15/2023 3:20:28 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W G-004 4 5 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC DESIGN SPECIFICATIONS 15 5 PART 3 - EXECUTION 3.1 EARTHWORK A. PROTECT SUBGRADES FROM SOFTENING, UNDERMINING, WASHOUT AND DAMAGE BY RAIN OR WATER ACCUMULATION. IF NECESSARY, INSTALL AND MAINTAIN A DEWATERING SYSTEM TO KEEP SUBGRADES DRY UNTIL IT IS NO LONGER NEEDED. B. STORAGE OF EXCAVATED MATERIALS 1. SEGREGATE EXCAVATED MATERIALS AS SHOWN ON THE PLANS. 2. STOCKPILE MATERIALS AWAY FROM EDGE OF EXCAVATIONS. C. EXCAVATION 1. PERFORM ALL EXCAVATION OF EVERY DESCRIPTION AND WHATEVER SUBSTANCE ENCOUNTERED INCLUDING ROCK AND PERMAFROST. EXCAVATE ONLY THE EXTENT INDICATED ON THE DRAWINGS, AND AS STAKED IN THE FIELD. ALL EXCAVATED MATERIALS SHALL BE PLACED AT A DISTANCE FROM THE TRENCH SECTION WHICH CONFORMS TO STATE AND/OR FEDERAL SAFETY CODES. 2. DO NOT BEGIN EXCAVATION UNTIL ALL MATERIALS, EQUIPMENT, AND PERSONNEL ARE PRESENT TO COMPLETE THE WORK IN THE MOST EXPEDIENT MANNER. D. BEDDING 1. PIPE SHALL BE PLACED IN BEDDING MATERIAL AS SPECIFIED AND AS SHOWN ON THE DRAWINGS. 2. WHERE BEDDING MATERIAL IS AVAILABLE FROM THE EXCAVATION, USE CARE TO SEPARATE IT FROM UNSUITABLE MATERIAL. PLACE BEDDING MATERIAL IN LIFTS NOT TO EXCEED TWELVE INCHES (12 ”), AND COMPACT TO NINETY-FIVE PERCENT (95%) OF MAXIMUM DENSITY. 3. PLACE BEDDING MATERIAL SO THAT IT DOES NOT FREE FALL FOR A DISTANCE GREATER THAN TWO FEET (2') ABOVE THE BASE OF EXCAVATION. E. BACKFILLING 1. BACKFILL MATERIAL SHALL BE OBTAINED FROM THE EXCAVATION. 2. PROMPTLY BEGIN BACKFILL OPERATIONS, BUT NOT BEFORE COMPLETING THE FOLLOWING: a. AS-BUILTING THE LOCATIONS OF NEW AND EXISTING PIPING AND UNDERGROUND UTILITIES FOR RECORD DOCUMENTS, b. REMOVING TRASH AND DEBRIS, c. REMOVING TEMPORARY SHORING, BRACING, AND SHEETING d. COMPACTING BEDDING MATERIAL TO LIMITS SPECIFIED AND SHOWN ON THE PLANS. 3. PLACE BACKFILL IN LIFTS AND COMPACT IN SUCH A MANNER THAT NINETY-FIVE PERCENT (95%) OF MAXIMUM DENSITY IS OBTAINED AS MEASURED IN ACCORDANCE WITH ASTM D1557, UNLESS OTHERWISE SPECIFIED. USE MECHANICAL MEANS TO ACHIEVE REQUIRED DENSITY, COMPACTION BY FLOODING WILL NOT BE ALLOWED. 4. FINAL GRADING OF FINISHED SURFACES SHALL MATCH PRECONSTRUCTION DRAINAGE PATTERNS, EXCEPT WHERE NOTED ON PLANS. 5. DISPOSAL OF EXCESS MATERIAL SHALL BE AT CONTRACTORS EXPENSE AT CONTRACTOR FURNISHED DISPOSAL SITE, AS APPROVED BY ENGINEER. 3.2 TOPSOIL A. PLACEMENT OF TOPSOIL SHALL NOT OCCUR UNTIL THE PROJECT AREA HAS BEEN INSPECTED AND APPROVED BY THE ENGINEER. B. USE STRIPPED TOPSOIL FROM EXCAVATIONS. IF SUFFICIENT QUANTITY OF ON-SITE TOPSOIL IS NOT AVAILABLE FURNISH TOPSOIL MEETING SPECIFICATIONS. C. ON AREAS TO RECEIVE TOPSOIL, THE COMPACTED SUBGRADE SOIL SHALL BE SCARIFIED TO A 2-INCH DEPTH FOR BONDING OF TOPSOIL WITH SUBSOIL. TOPSOIL THEN SHALL BE SPREAD EVENLY TO A THICKNESS OF 12 INCHES AFTER COMPACTION AND GRADED TO THE ELEVATIONS AND SLOPES SHOWN. TOPSOIL SHALL NOT BE SPREAD WHEN FROZEN OR EXCESSIVELY WET OR DRY. D. TOPSOIL SHALL BE PLACED IN ALL DISTURBED AREAS WHERE VEGETATION EXISTS PRIOR TO CONSTRUCTION, UNLESS OTHERWISE NOTED. E. MAINTAIN AREAS COVERED BY TOPSOIL UNTIL SUBSEQUENT SEEDING IS ACCOMPLISHED. REPAIR AND REESTABLISH GRADES TO SPECIFIED TOLERANCES WHERE COMPLETED OR PARTIALLY COMPLETED SURFACES BECOME ERODED, RUTTED, SETTLED, OR WHERE THEY LOSE COMPACTION DUE TO SUBSEQUENT CONSTRUCTION OPERATIONS OR WEATHER CONDITIONS. COMPLETE ANY REPAIRS OR TOPSOIL REPLACEMENT, INCLUDING DAMAGE OR LOSS RESULTING FROM WINTER SHUTDOWN, WITHOUT EXTRA COMPENSATION. 3.3 SEEDING A. AFTER GRADING IS COMPLETED AND BEFORE BEGINNING SEEDING, AREAS SHALL BE CULTIVATED TO PROVIDE A REASONABLY FIRM BUT FRIABLE SEEDBED. CULTIVATED AREAS SHALL BE RAKED OR CLEARED OF STONES TWO INCH (2”) IN DIAMETER AND LARGER, WEEDS, PLANT GROWTH, STICKS, STUMPS, AND OTHER DEBRIS OR IRREGULARITIES WHICH MIGHT INTERFERE WITH SEEDING. B. APPLY SEED MIX AT 5 LBS PER 1,000 SQUARE FEET. APPLY FERTILIZER AT A RATE TO PROVIDE TWO (2) POUNDS ACTUAL NITROGEN PER THOUSAND (1,000) SQUARE FEET OF AREA. C. AFTER SEEDING, PROMPTLY REPAIR SURFACES THAT ARE GULLIED OR OTHERWISE DAMAGED BY REGRADING AND RESEEDING AS NEEDED. WATER AND MAINTAIN SEEDED AREAS IN A SATISFACTORY CONDITION UNTIL FINAL INSPECTION AND ACCEPTANCE OF THE WORK. RESEED ANY AREAS NOT SHOWING EVIDENCE OF SATISFACTORY GROWTH WITHIN 3 WEEKS OF SEEDING. D. SEED APPLICATION SEASON SHALL BE BETWEEN MAY 15 AND AUGUST 15 3.4 PIPES AND FITTINGS A. DELIVERY, STORAGE AND HANDLING 1. DO NOT STORE PLASTIC STRUCTURES, PIPE AND FITTINGS IN DIRECT SUNLIGHT. 2. PROTECT PIPE, FITTINGS AND SEALS FROM DIRT AND DAMAGE. B. PIPE GRADE AND ALIGNMENT 1. PIPING SHALL BE LAID AT THE GRADE AND ALIGNMENT SHOWN ON THE DRAWINGS. INSTALL PIPING AS INDICATED. NOTIFY ENGINEER IF CONFLICTS WITH OTHER UTILITIES REQUIRE MODIFICATIONS. 2. MINIMUM PIPE SLOPE FOR 4" DIAMETER GRAVITY PIPING SHALL BE (1/4" PER FT). MAXIMUM PIPE SLOPE SHALL BE 20%. TEN FEET PRIOR TO SEPTIC TANK AND TEN FEET AFTER TANK SHALL NOT EXCEED (1/4" PER FT) SLOPE. 3. DURING THE PROGRESS OF THE WORK, CONTRACTOR SHALL PROVIDE INSTRUMENTS SUCH AS TRANSITS, LEVELS, LASER DEVICES, AND OTHER FACILITIES FOR TRANSFERRING GRADES FROM OFFSET HUBS OR FOR SETTING OF BATTER BOARDS OR OTHER CONSTRUCTION GUIDES FROM THE CONTROL POINTS AND BENCH MARKS PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL PROVIDE QUALIFIED PERSONNEL TO USE SUCH INSTRUMENTS AND WHO HAVE THE DUTY AND RESPONSIBILITY FOR PLACING AND MAINTAINING SUCH CONSTRUCTION GUIDES. 3.5 RIGID INSULATION BOARD & FROST PROTECTION A. MINIMUM DEPTH OF BURY FOR RESIDENTIAL WASTEWATER SYSTEM COMPONENTS IN THE ANCHORAGE AREA SHALL BE 2.5 FEET (2.5') OF COMPACTED SOIL COVER WITH 2" OF RIGID INSULATION BOARD AS SPECIFIED ON THE PLANS FOR FROST PROTECTION. INSULATION IS NOT NEEDED WHERE COMPACTED SOIL COVER IS 4.5 FEET (4.5') OR MORE AS SPECIFIED ON PLANS. B. INSULATION BOARD SHALL BE PLACED ON A PREPARED SUBGRADE SHAPED TO THE LINES AND GRADES SHOW ON THE DRAWINGS AND PROVIDE A SMOOTH SURFACE ON WHICH TO PLACE THE INSULATION. C. INSULATION JOINTS SHALL BE STAGGERED SO THAT AN OVERLAP OF AT LEAST ONE FOOT IS OBTAINED. D. CONTRACTOR SHALL REPLACE OR REPAIR ANY PANELS BROKEN, CRUSHED, OR CRACKED AT NO COST TO THE OWNER. E. INSULATION BOARD SHALL BE COVERED WITH SELECTED BACKFILL MATERIAL CONTAINING NO ROCKS GRATER THAN 2-INCHES, PLACED IN 12-INCH LIFT, SPREAD, AND COMPACTED FOR THE FULL WIDTH OF THE INSULATION LAYER PRIOR TO PLACING SUBSEQUENT LIFTS. PLACING AND SPREADING, AND ALL COMPACTION SHALL BE ACCOMPLISHED IN SUCH A MANNER AS NOT TO DAMAGE THE INSULATION BOARD. 3.6 SEPTIC SYSTEM DECOMMISSIONING A. COMPLY WITH ALL ADEC REQUIREMENTS RELATED TO DECOMMISSIONING AND ABANDONMENT OF SEPTIC SYSTEMS. B. COMPLETELY PUMP OUT EXISTING SEPTIC TANK PRIOR TO BEGINNING REMOVAL OPERATIONS. DISPOSE OF SEPTAGE AT ADEC/ENGINEER APPROVED LOCATION. C. EXCAVATE AND REMOVE EXISTING SEPTIC TANK. REPLACE EXCAVATED MATERIAL AND PLACE ADDITIONAL FILL MATERIAL TO MATCH NATIVE. FILL SHALL HAVE NO STONES LARGER THAN 3-INCHES IN ANY DIMENSION. COMPACT TO 95% MAXIMUM DENSITY. CAP THE OPEN END OF LEACH FIELD AND LEAVE EXISTING LEACH FIELD PIPING IN PLACE. SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\General\ANC-G-STGENL-4.dwg LAYOUT: DESIGN SPECS 3 PRINTED: 9/15/2023 3:20:28 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W G-005 5 5 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC DESIGN SPECIFICATIONS 15 6 PART 4 - INSPECTIONS & SEPARATION DISTANCES A. ONSITE INSPECTIONS 1. CONTRACTOR SHALL NOTIFY ANTHC AND ENGINEER 24 HRS IN ADVANCE OF ANTICIPATED CONSTRUCTION SCHEDULE FOR ALL INSTALLATIONS. CONTRACTOR TO NOTIFY ENGINEER 8 HRS PRIOR TO EACH INSPECTION STEP TO COORDINATE OBSERVATION BY ENGINEER AND/OR MOA. 2. ENGINEER SHALL CONDUCT ON-SITE INSPECTIONS DURING INSTALLATION OF SOIL ABSORPTION SYSTEM (SAS) ACCORDING TO AMC 15.65.070. WE PROPOSE THE FOLLOWING INSPECTIONS FOR PROPOSED SAS: a. PRE-CONSTRUCTION TO VERIFY LAYOUT AND PLANS b. AFTER EXCAVATION TO OBSERVE BOTTOM OF HOLE c. AFTER PLACEMENT OF DRAIN ROCK UNDER LATERALS AND MONITOR TUBES ARE INSTALLED d. AFTER FINAL BACKFILL 3. ENGINEER SHALL CONDUCT A MINIMUM OF TWO INSPECTIONS FOR THE INSTALLATION OF SEPTIC TANK a. AN INSPECTION SHALL BE CONDUCTED AFTER TANK IS SET WITH DISTRIBUTION PIPING AND CLEANOUTS INSTALLED, BUT PRIOR TO BACKFILL. b. TANK SHALL BE INSPECTED AFTER BACKFILL TO VERIFY FINAL GRADING, ELECTRICAL EQUIPEMENT INSTALLATION, AND LOCATIONS OF ALL STANDPIPES. B. AS-BUILT SURVEY 1. AN AS-BUILT SURVEY IS TO BE COMPLETED BY ANTHC AFTER THE CONSTRUCTION OF THE ON-SITE WASTEWATER SYSTEM HAS BEEN COMPLETED. THE SURVEY IS TO INCLUDE THE FOLLOWING. a. ALL STRUCTURES, DRIVEWAYS, PARKING AREAS, SEPTIC SYSTEM STANDPIPES, AND WATER WELLS ON LOT. b. ALL RESIDENTIAL WELLS WITHIN 100' OF LOT LINES SHALL BE INCLUDED, AND ALL PUBLIC WATER WELLS WITHIN 200' OF LOT SHALL BE INCLUDED. c. ALL SURFACE WATER BODIES, STREAMS, AND LAKES SHALL BE INCLUDED WITHIN 100' OF LOT. 2. AS-BUILT SURVEY IS TO BE PERFORMED BY ANTHC ONE WEEK AFTER CONTRACTOR COMPLETES WASTEWATER SYSTEM, AND COMPLETED SURVEY PROVIDED TO HDL WITHIN TWO WEEKS AFTER COMPLETION OF WASTEWATER SYSTEM CONSTRUCTION. COMPLY WITH STATE OF ALASKA REGULATIONS FOR MINIMUM SEPARATION REQUIREMENTS BELOW. IF CONTRACTOR DISCOVERS A CONFLICT BETWEEN THE DESIGN AND REQUIREMENTS BELOW, CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY FOR RESOLUTION. WHERE THE LOCATION OF THE ONSITE SEWER SYSTEM IS NOT CLEARLY DEFINED BY THE DIMENSIONS ON THE DRAWINGS, THE SYSTEM SHALL NOT BE CLOSER HORIZONTALLY THAN 10 FEET TO A WATER SUPPLY MAIN. WHERE GRAVITY FLOW SEWER LINES CROSS ABOVE OR BELOW WATER LINES, THE SEWER PIPE SHALL HAVE A MINIMUM VERTICAL SEPARATION OF EIGHTEEN (18) INCHES AND THE SEWER PIPE SHALL BE FULLY ENCASED IN HDPE PIPE FOR A DISTANCE OF TEN (10) FEET ON EACH SIDE OF THE CROSSING. THE SEPTIC TANK AND DRAIN FIELD SHALL MAINTAIN HORIZONTAL SEPARATION DISTANCES OF: 1. 100 FT. FROM A PRIVATE WELL; 200' FROM PUBLIC WELL. 2. 100 FT. TO THE ANNUAL MEAN HIGH WATER LEVEL OF RIVERS, LAKES, STREAMS AND SPRINGS 3. 10 FT. TO THE HOUSE FOUNDATION AND WATER LINES (SEE ABOVE) 4. 5 FT. MINIMUM BETWEEN SEPTIC TANK AND DRAIN FIELD (ACCORDING TO MOA 15.65.205) MINIMUM SEPARATION DISTANCES TABLE FROM ADEC ONSITE INSTALLERS MANUAL IS PROVIDED BELOW AS A REFERENCE. WHERE THERE ARE CONFLICTS BETWEEN THIS TABLE & MUNICIPALITY OF ANCHORAGE CODE THE MUNICIPALITY OF ANCHORAGE CODE 15.65 SHALL PREVAIL. SEPARATION DISTANCE REQUIREMENTS SITE STRUCTURES WATER POWER AND COMMUNICATION ELECTRIC PED ELECTRIC METER THERMISTOR TELEPHONE BOOTH CABLE PED ELECTRICAL VAULT SANITARY SEWER TOPO AND VEGETATION HYDRANT WATER VALVE WATER WELL WATER MANHOLE WATER VALVE VAULT SEWER MANHOLE CLEANOUT SEPTIC VENT SEWER LIFT STATION SEPTIC TANK ARCTIC BOX LIGHT POLE POWER POLE ELECTRIC TRANSFORMER TELEPHONE PEDESTAL ANTENNA FUEL POWERED GENERATOR HYDRO POWERED GENERATOR WIND POWERED GENERATOR RUNWAY LIGHT TAXIWAY LIGHT SLOPE ARROW BOLLARD FUEL TANK PROPANE TANK GATE POST MONITOR WELL SIGN TEST PIT THERMOSYPHON TM E W W W A CO E FG HG WG L S TP V E EM TB C ST AB B FT G MW PT DRAINAGE CHANNELSTREET LIGHT RIP RAP STRAW BALE GRAVEL ROAD OR DRIVEWAY WATER ELEVATION THAW PORT NATURAL DRAINAGE CB CATCH BASIN AIR RELIEF VALVE CONTROL VALVESSEWER VALVE VAULT PULL BOXPB EXPANSION JOINT LINE LABELS OH/E CULVERT WATER SANITARY SEWER TOPOGRAPHY AND VEGETATION POWER AND COMMUNICATION WS SS SITE WATER SERVICE SEPTIC SEWER SERVICE X X FENCE LINE MAJOR CONTOUR MINOR CONTOUR OVERHEAD POWER LINE 220 219 CABLE TV BURIED FIBEROPTIC BURIED F F UG NATURAL GAS LINE CATV FO BELOW GROUND SANITARY SEWER TP-XX SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\Civil\ANC-C-SPSITE-04.dwg LAYOUT: CIVIL LEGEND PRINTED: 9/15/2023 3:20:16 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W C-001 1 4 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC CIVIL LEGEND 15 7 FOUND 5/8" REBARX PROPERTY LINE EASEMENT CC UG COMMUNICATION LINE UG/E UG POWER LINE TREE LINE 800.0'SPOT ELEVATION G NATURAL GAS METER 1500 GALLON STEEL EPOXY COATED SEPTIC TANK ANCHORAGE TANK OR EQUAL SS EM SKI ES DR I VE 12" DIAMETER DRIVEWAY CULVERT TP TP TP TP VV V GROUND FLOOR FF = 413.4' DECK FF = 422.0' APPROX. LOCATION UG COMMUNICATION LINE & UG POWER LINE +/- 2' BRICK RETAINING WALL +/- 2' BRICK RETAINING WALL MULTI STORY WOOD FRAME HOUSE SHED CLEANOUT VERTICAL BEND -3.2' BELOW GRADE JB APPROX. LOCATION UG WATER SERVICE LINE PAVED DRIVEWAY 15' TELEP H O N E & E L E C T R I C E A S E M E N T +/- 2' BRICK RETAINING WALL SP CO ST S T V V SS SS SS S S S S SS SS SS S S S S 0+79 0+ 0 0 0+ 2 0 0 + 4 0 0 + 6 0 405 41 0 415 403 403 404 406 407 408 409 411 412 413 414 416 417 418 419 416 413 405 410 415 406 407 408 409 411 412 413 414 416 41 7 418 CO HDL TP-01 30' RADIUS TEST PIT 1986 TEST PIT APPROX. LOCATION S S S S S S CO CO REMOVE EXISTING SEPTIC TANK EXISTING BED SAS 8.6' SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\Civil\ANC-C-SPSITE-04.dwg LAYOUT: SITE PLAN PRINTED: 9/15/2023 6:28:06 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W C-101 2 4 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC SITE PLAN 15 8 0 10' 20' 3 0 ' 40' 6 ' O C CO-01 CO-02 ST-01 NOTES 1. REMOVE EXISTING BED SAS (OUTSIDE FOOTPRINT OF DRIVEWAY) AND HAUL DRAIN ROCK & CONTAMINATED SOILS OFFSITE. 2. REMOVE EXISTING SEPTIC TANK 3. PROPOSED SEPTIC TANK AND SOIL ABSORPTION SYSTEM TO BE MINIMUM OF 10' FROM WATER SERVICE LINE 4. CONTRACTOR TO CONSTRUCT BED SOIL ABSORPTION SYSTEM (SAS) WITHOUT TRACKING EQUIPMENT OVER BOTTOM OF SAS DURING CONSTRUCTION. ONE WAY TO ACCOMPLISH THIS IS WORKING FROM ONE SIDE OF SAS TO THE OTHER. 5. INSTALL CLEANOUTS ON ENDS OF LATERALS AS REQUIRED BY MUNICIPALITY OF ANCHORAGE (AMC 15.65.210 E5). SWING TIE DATA FROM TO DESCRIPTION DESIGN DISTANCE AB NEW SEPTIC SYSTEM RISER 40.8' NEW SEPTIC SYSTEM RISER 16.9' NEW SEPTIC SYSTEM RISER 44.3' NEW SEPTIC SYSTEM RISER 23.7' CLEANOUT 5.0' CLEANOUT 29.8' NEW MONITOR TUBE 75.8' NEW MONITOR TUBE 43.9' NEW MONITOR TUBE 61.6' NEW MONITOR TUBE 55.7' NEW MONITOR TUBE 89.5' NEW MONITOR TUBE 79.6' NEW MONITOR TUBE 99.8' NEW MONITOR TUBE 71.8' A B A B A B A B A B A B A B ~ 6 . 9 ' 2 2 ' CONSTRUCT SAS MIN OF 22' FROM DITCH ELEVATION CHANGE FROM INVERT OF LATERAL TO DITCH IS APPROXIMATELY 4' C - 3 0 1 A 1 MAJOR STRUCTURES ID STATION DESCRIPTION CO-01 0+02.9 DOUBLE CLEAN-OUT, SEE SSD-301 ST-01 0+19.1 1500 GALLON STEEL EPOXY COATED SEPTIC TANK ANCHORAGE TANK OR EQUAL CO-02 0+30.0 DOUBLE CLEAN-OUT, SEE SSD-301 SOIL ABSORPTION SYSTEM 30'X40' (10) LATERALS MIN 17' LONG SPACED 6' O.C. AND 3' FROM EDGE FIELD VERIFY UTILITY EASEMENT PRIOR TO CONSTRUCTION EL E V A T I O N EL E V A T I O N 390' 400' 410' 420' 430' 390' 400' 410' 420' 430' A0+00 A0+10 A0+20 A0+30 A0+40 A0+50 A0+60 A0+70 A0+79 EG : 4 1 3 . 3 ' EG : 4 1 2 . 6 ' EG : 4 1 2 . 4 ' EG : 4 1 2 . 5 ' EG : 4 1 2 . 4 ' EG : 4 1 1 . 9 ' EG : 4 1 1 . 4 ' EG : 4 1 0 . 8 ' EG : 4 1 0 . 1 ' SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2023 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\Civil\ANC-C-SPSITE-04.dwg LAYOUT: PROFILE PRINTED: 9/15/2023 3:20:11 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W C-102 3 4 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC PROFILE 15 9 · SEASONAL HIGH GROUNDWATER ESTIMATED AT 12.3' BASED ON DEPTH OF TEST PIT. · PROVIDE A MINIMUM 2.5' OF BACKFILL OVER 2" OF INSULATION FOR FROST PROTECTION OR 4.5' OF SOIL COVER WHERE NOT INSULATED. · PLACE INSULATION OVER SEPTIC TANK SO IT EXTENDS 2.0' PAST EDGE OF SEPTIC TANK ON ALL SIDES · SCH 40 ABS CLEANOUT WITH 90 DEGREE LONG SWEEP ELBOW AT END OF EACH LATERAL TYP. NOTES 1 2 3 MAJOR STRUCTURES ID STATION DESCRIPTION CO-01 0+02.9 DOUBLE CLEAN-OUT, SEE SSD-301 ST-01 0+19.1 1500 GALLON STEEL EPOXY COATED SEPTIC TANK ANCHORAGE TANK OR EQUAL CO-02 0+30.0 DOUBLE CLEAN-OUT, SEE SSD-301 GRADING TABLE ID DESCRIPTION ELEV AB A SEPTIC TANK 405.3 B TANK BEDDING 404.3 C COVER / FILL VARIES D BOTTOM OF 1.5' SEWER ROCK 406.0' E BOTTOM OF 4" LATERALS 407.0' F TOP OF SEWER ROCK 407.5' 1ST FF ELEV = 413.4' ST - 0 1 CO - 0 2 CO - 0 1 FG EG / FG 4' RISERS 24" Ø INSULATED SEE SSSD-567 PROFILE - SCATTERED SITES - SITE 4 - NORTH WOODS UNIT 4 BLOCK 17 LOT 7A11" = 5' 1500 GALLON SEPTIC TANK 10' LONG, 64"Ø 2" INSULATION 32 4" SCH 40 PVC SUPPLY LINE 4" LATERALS SCH 40 PVC PERFORATED PIPE 2" INSULATION (ENTIRE BED) AND 2.5' OF SOIL COVER MIN 2" INSULATION 2 SCH 40 ABS 10' PRIOR TO TANK 2% SLOPE 20% SLOPE MAX 9"7" D E F 10' AFTER TANK 2% SLOPE FG 1 12" OF SEWER ROCK BELOW LATERALS AND MIN 2" OF SEWER ROCK ABOVE LATERALS >4' TO SEASONAL HIGH GROUND WATER TABLE >6' TO IMPERMEABLE SOILS OR BEDROCK GEOTTEXTILE FABRIC STA 0+48 FG = 412.0' EG = 412.0' STA 0+76 FG= 410.4' EG= 410.4' 4 4 TYPICAL LEACH FIELD SECTION - SITE 4A1N.T.S. 1. GROUNDWATER LEVEL ASSUMED 12.3 FT BELOW GRADE BASED ON DEPTH OF TEST PIT. 2. SLOPE WALLS AS REQUIRED FOR SAFETY. 3. CONTRACTOR SHALL NOTIFY THE ENGINEER AND ANTHC 24 HOURS PRIOR TO EXCAVATING FOR THE INSTALLATION OF THE SYSTEM TO VERIFY SUBSURFACES MEET MOA REQUIREMENTS; TO COORDINATE DOCUMENTATION FOR SUBMITTAL. 4. CONTRACTOR TO CONSTRUCT BED SOIL ABSORPTION SYSTEM WITH OUT TRACKING EQUIPMENT OVER SOIL ABSORPTION SYSTEM. 5. INSTALL CLEANOUTS ON ENDS OF LATERALS AS REQUIRED BY MUNICIPALITY OF ANCHORAGE (AMC 15.65.210 E5). NOTES 3' 6' 3'6' 6' 12" SEWER ROCK BELOW LATERALS 2.5' MIN BACKFILL FROM EXCAVATION 12" MIN 4" LATERALS SCH 40 PVC PERFERATED PIPE GEOTEXTILE FABRIC INSTALLED OVER SEWER ROCK 2" INSULATION INSTALLED OVER GEOTEXTILE FABRIC 18" SEWER ROCK MIN 2" ABOVE TOP OF PIPE 4" MONITOR TUBE AT EACH CORNER OF THE SOIL ABSORPTION SYSTEM BED. PERFORATED IN THE SEWER ROCK ONLY. MOUND SOIL MIN 6" ABOVE EXISTING GRADE TO ACCOUNT FOR SETTLING 1 1' *2 4' MIN VERTICAL SEPARATION TO SEASONAL HIGH GROUND WATER TABLE 6' MIN VERTICAL SEPARATION TO IMPERMEABLE SOIL OR BEDROCK CAPPED MONITOR TUBES IN EACH CORNER NATIVE SAND SHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 MR K D A T E DE S C R I P T I O N PROJ MGR: DRAWN BY: DRUMS ENG: PROJ ENG: PLAN SET: SHEET TITLE Division of Environmental Health and Engineering IN I T BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MFONDREN PRODUCT: AutoCAD 2016 - English FILE: H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\CAD\Drawings\Site 4\Civil\ANC-C-SPPRFL-04.dwg LAYOUT: SECTION PRINTED: 9/15/2023 3:20:16 PM 0 1" TOTAL SHEETSOF AN C H O R A G E , A L A S K A SC A T T E R E D S I T E S - S I T E 4 NO R T H W O O D S U N I T 4 BL O C K 1 7 L O T 7 IS S U E D F O R R E V I E W C-301 4 4 J. ERHARDT C. BOWMAN M. FONDREN AKA-22-ANC SECTION 15 10 1 2 SEE NOTE 2" SEWER ROCK ABOVE LATERALS 6' SCH 40 ABS CLEANOUTS WITH 90 DEGREE LONG SWEEP ELBOW AT EACH END OF LATERALS TYP. EXISTING GRADE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231261, Curtis Townsend, 09/19/23 Geotechnical Memo, Cox Residence - North Woods Unit 4 B17 L7 July 17, 2023 2 rate, based on the last measurement, was approximately 8 minutes per inch. See the 1986 Percolation Test Log for additional soil and percolation test information. In September 1997, KND Engineering performed a percolation test between 4 feet and 5 feet bgs on the neighboring lot approximately 175 feet northeast of TP-01 and approximately 2 feet higher in elevation than the Site. The test pit generally encountered silty sand and gravel with cobbles up to 4 inches in diameter. The percolation test on the neighboring lot generally followed MOA methodology for fast percolation tests. KND took a measurement of the water level drop to the nearest 1/16 inch every 10 minutes. The measured percolation rate, based on the last measurement, was approximately 13.33 minutes per inch. See the 1997 Percolation Test Log for additional soil and percolation test information. A percolation rate of 8 minutes per inch informed the current bed system design and the current system has lasted almost 30 years. Per MOA Code Chapter 15.65.210, Table 2, the historic percolation test performed at the Site and the neighboring lots indicate that the soils fall within the 6 to 15 minutes per inch category. Based on MOA Code, soils with a percolation rate of 6 to 15 minutes per inch may use an application rate of 0.5 gallons per day (gpd) per square foot for design of a bed system. Design of the bed system at the Site will utilize an application rate of 0.5 gpd per square foot. We appreciate the opportunity to provide this service. If you have any questions, please feel free to contact Jeremy Dvorak at jdvorak@hdlalaska.com or 907.564.2121. Attach: Limitations (2 Pages) Boring Log Key (1 Page) Test Pit Log (1 Page) Grain Size Distribution Curve (1 Page) 1986 Percolation Test Log 1986 (1 Page) 1997 Percolation Test Log 1997 (1 Page) Site Plan (1 Page) CC:Mark Fondren, PE (HDL) Mark Landon (ANTHC) H:\jobs\18-021 ANTHC Term Contract 18-TC-161654 (ANTHC)\58 - Well and Septic Designs - 6 Anchorage Homes\03 - Si Info\Site 4 - Cox (North Woods Unit 4 B17 L7)\Geotech\18-021-58 Site 4 Perc Memo.docx GEOTECHNICAL LIMITATIONS Use of Report 1.HDL Engineering Consultants, LLC (HDL) prepared this report on behalf of, and for the exclusive use of our Client for the stated purpose(s) and location(s) identified in the Proposal for Services and/or Report. Use of this report, in whole or in part, at other locations, or for other purposes, may lead to inappropriate conclusions; and we do not accept any responsibility for the consequences of such use(s). Further, reliance by any party not expressly identified in the agreement, for any use, without our prior written permission, shall be at that party’s sole risk, and without any liability to HDL. 2. If substantial time has elapsed between submission of this report and the start of work at the site, or if conditions have changed because of natural causes or construction operations at or adjacent to the site, we recommend that HDL be retained to review this report to determine the applicability of the conclusions considering the time lapse or changed conditions. Standard of Care 3. HDL’s findings and conclusions are based on the work conducted as part of the Scope of Services set forth in the Proposal for Services and/or Report, and reflect our professional judgment. These findings and conclusions must be considered not as scientific or engineering certainties, but rather as our professional opinions concerning the limited data gathered during the course of our work. If conditions other than those described in this report are found at the subject location(s), or the design has been altered in any way, HDL shall be so notified and afforded the opportunity to revise the report, as appropriate, to reflect the unanticipated changed conditions. 4. HDL’s services were performed using the degree of skill and care ordinarily exercised by qualified professionals performing the same type of services, at the same time, under similar conditions, at the same or a similar property. No warranty, expressed or implied, is made. Subsurface Conditions 5.The generalized soil profile(s) provided in our Report are based on widely-spaced subsurface explorations and are intended only to convey trends in subsurface conditions. The boundaries between strata are approximate and idealized, and were based on our assessment of subsurface conditions. The composition of strata, and the transitions between strata, may be more variable and more complex than indicated. For more specific information on soil conditions at a specific location refer to the exploration logs. 6. Unanticipated soil conditions are commonly encountered and cannot be fully determined by merely taking soil samples or advancing borings. Such unexpected conditions frequently require additional expenditure to attain a properly constructed project. Therefore, some contingency fund is recommended to accommodate such potential extra costs. 7. In preparing this report, HDL relied on certain information provided by the Client, state and local officials, and other parties referenced therein which were made available to HDL at the time of our evaluation. HDL did not attempt to independently verify the accuracy or completeness of all information reviewed or received during the course of this evaluation. 8. Water level readings have been made in test holes (as described in the Report) and monitoring wells at the specified times and under the stated conditions. These data have been reviewed and interpretations have been made in this Report. Fluctuations in the level of the groundwater occur due to temporal or spatial variations in areal recharge rates, soil heterogeneities, the presence of subsurface utilities, and/or natural or artificially induced perturbations. The water encountered in the course of the work may differ from that indicated in the Report. 9. HDL’s services did not include an assessment of the presence of oil or hazardous materials at the property. Consequently, we did not consider the potential impacts (if any) that contaminants in soil or groundwater may have on construction activities, or the use of structures on the property. 10. Recommendations for foundation drainage, waterproofing, and moisture control address the conventional geotechnical engineering aspects of seepage control. These recommendations may not preclude an environment that allows the infestation of mold or other biological pollutants. Compliance with Codes and Regulations 11. We used reasonable care in identifying and interpreting applicable codes and regulations. These codes and regulations are subject to various, and possibly contradictory, interpretations. Compliance with codes and regulations by other parties is beyond our control. Additional Services 12. HDL recommends that we be retained to provide services during any future: site observations, design, implementation activities, construction and/or property development/redevelopment. This will allow us the opportunity to: i) observe conditions and compliance with our design concepts and opinions; ii) allow for changes in the event that conditions are other than anticipated; iii) provide modifications to our design; and iv) assess the consequences of changes in technologies and/or regulations. BORINGLOGKEY COMPONENT PROPORTION (Visual) Term Range Trace 0 ‐ 5% Little 5 ‐ 15% Some  15 ‐ 30% And 30 ‐ 50% SAMPLE TYPES Symbol Description SS Split Spoon MSS Modified Split Spoon G Grab ST Shelby Tube DP Push Sample C Core SOIL CONSISTENCY Description N‐Value Pocket Pen. Very Soft <2 <0.25 Soft 2 ‐ 4 0.25 ‐ 0.5 Medium 4 ‐ 8 0.5 ‐ 1.0 Stiff 8 ‐ 15 1.0 ‐ 2.0 Very Stiff 15 ‐ 30 2.0 ‐ 4.0 Hard >30 >4.0 RELATIVE SOIL DENSITY Description N‐Value Very Loose 0 ‐ 4 Loose 5 ‐ 10 Medium Dense 11 ‐ 30 Dense 31 ‐ 50 Very Dense >50 NOTES: Visual soil descriptions performed in accordance with ASTM D2488 Lowercase USCS abbreviation indicates field classification Uppercase USCS abbreviation indicates laboratory classification ABased on the material passing the 3-in. (75-mm) sieve BIf field sample contained cobble or boulders, or both, add "with cobbles or boulders, or both" to group name CGravels with 5 to 12% fines require dual symbols: GW-GM well-graded gravel with silt GW-GC Well-graded gravel with clay GP-GM poorly graded gravel with silt GP-GC poorly graded gravel with clay D Cu=D60/D10, Cc=(D30) 2 /(D10xD60) EIf soil contains ≥ 15% sand, add "with sand" to group name FIf fines classify as CL-ML, use dual symbol GC-GM, or SC-SM GRAIN SIZE Size Class Inches mm Boulders >12 inches >300 Cobbles 3 to 12 75 ‐ 300 Gravel Coarse  3/4 ‐ 3 19.0 ‐ 75 Fine 3/16 ‐ 3/4 4.76 ‐ 19.0 Coarse 1/16 ‐ 3/16 2.0 ‐ 4.76 Medium 1/64 ‐ 1/16 0.42 ‐ 2.0 Fine 1/256 ‐ 1/64 0.074 ‐ 0.42 Silt and Clay <1/256 <0.074 Sand Summary of the Unified Soil Classification System (from ASTM International Standard D2487)A Soil Classification Group Symbol Group NameB Coarse‐grained Soils (More than 50% retained on No. 200 sieve) Gravels (More than 50% of coarse fraction retained on No. 4 sieve) Gravels with < 5% finesC Cu≥4 and 1≤Cc≤3D GW Well‐graded gravelE Cu<4 and/or [CC<1 or CC>3]D GP Poorly graded gravelE Gravels with > 12% finesC Fines classify as ML or MH GM Silty gravelE,F,G Fines classify as CL or CH GC Clayey gravelE,F,G Sands (50% or more of coarse fraction passes No. 4 sieve) Sands with < 5% finesH Cu≥6 and 1≤Cc≤3D SW Well‐graded sandI Cu<6 and/or [Cc<1 or Cc>3]D SP Poorly graded sandI Sands with > 12% finesH Fines classify as ML or MH SM Silty sandF,G,I Fines classify as CL or CH SC Clayey sandF,G,I  Fine‐grained Soils (More than 50% passes the No. 200 sieve) Silts and Clays (LL<50) Inorganic PI>7 and plots on or above "A" lineJ CL Lean clayK,L,M PI<4 or plots below "A" lineJ ML SiltK,L,M  Organic LL ‐ Oven dried/LL ‐ Not dried <0.75 OL Organic clay/siltK,L,M,N/O Inorganic PI plots on or above "A" line CH Fat clayK,L,M PI plots below "A" line MH Elastic siltK,L,M Organic LL ‐ Oven dried/LL ‐ Not dried <0.75 OH Organic clay/siltK,L,M,P/Q Highly Organic Soils Primarily organic matter, dark in color, and organic odor PT Peat Silts and Clays (LL≥50) GIf fines are organic, add "with organic fines" to group name HSands with 5 to 12% fines require dual symbols: SW-SM well-graded sand with silt SW-SC well-graded sand with clay SP-SM poorly graded sand with silt SP-SC poorly graded sand with clay IIf soil contains ≥15% gravel, add "with gravel" to group name JIf Atterberg limits plot in hatched area, soil is a CL-ML, silty clay KIf soil contains 15 to < 30% plus No. 200, add "with sand" or "with gravel", whichever is predominant LIf soil contains ≥ 30% plus No. 200, predominantly sand, add "sandy" to group name MIf soil contains ≥ 30% plus No. 200, predominatly gravel, add "gravelly” to group name NPI ≥ 4 and plots on or above "A" line OPI < 4 or plots below "A" line PPI plots on or above "A" line QPI plots below "A" line BOH 13.3 gp-gm sm gm S-1 S-2 S-7 S-3 S-4 S-5 S-6 GRAB GRAB GRAB GRAB GRAB GRAB GRAB 13.3 ORGANIC MAT Poorly-graded GRAVEL, (gp-gm); fine to coarse; subangular to subrounded, little sand; fine to coarse; trace to little silt; brown, dry, with cobbles Moisture =12.3% SAND, (sm); fine to coarse; some gravel; some silt; brownish gray, moist; Moisture =22.7% with cobbles P200 =28.5%, Sa =42.7%, Gr =28.8%, Moisture =9.9% Moisture =7.2% P200 =29.2%, Sa =47.0%, Gr =23.8%, Moisture =10.6% Moisture =7.6% GRAVEL, (gm); fine to coarse; some to with sand; fine to coarse; little to some silt; brownish gray, moist; Moisture =6.6% Notes: Installed 2-inch diameter slotted PVC pipe to a depth of 13.3 feet bgs for groundwater monitoring. No groundwater encountered. Performed percolation test at approximately 5 feet bgs. 0.0 0.3 4.0 5.0 7.0 12.0 Equipment Type: CAT 308C Location: ~27 feet S of W clean out Lat/Long: Total Depth: 13.3 feet Date: 6/21/2023Field Crew: Dakota Diggers, LLC PROJECT NUMBER: 18-021-58.4 PROJECT: Cox Residence - North Woods Unit 4 B17 L7 CLIENT : ANTHC Sa m p l e Sample Data De p t h ( F e e t ) Sa m p l e T y p e US C S Cl a s s i f i c a t i o n Fr o z e n Z o n e Ground Water Data Sa m p l e # Geologist: S. Huff So i l G r a p h i c 0 1 2 3 4 5 6 7 8 9 10 11 12 13 LOG OF TEST PIT TEST PIT # TP-01 6/21/23 SUBSURFACE MATERIAL Sheet Number 1 of 1Sheet Number 1 of 1Sheet Number 1 of 1Sheet Number 1 of 1 Depth in (ft.) Time Date Symbol B U S C S L O G O F T E S T P I T 1 8 - 0 2 1 - 5 8 . 4 L O G S . G P J H D L M O D I F I E D . G D T 7 / 1 0 / 2 3 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0.0010.01 0.1 110 100 medium 6 D30 16 20 30 40 50 1.5 6 GRAIN SIZE IN MILLIMETERS PE R C E N T F I N E R B Y W E I G H T coarse fine coarse 42.7 47.0 1.35 0.901 50.8 25.4 0.085 0.079 200 D100 D60 GRAVEL SAND SILT OR CLAY 4 TP-01 TP-01 LL PL D10 4 1 60 fine DEPTH 5.0 DEPTH 7.0 HYDROMETERU.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 28.5 29.2 3/4 1/2 3/8 3 %Gravel %Sand %Silt %Clay TP-01 TP-01 100 1403 2 COBBLES 28.8 23.8 DEPTH 5.0 DEPTH 7.0 8 10 14 Specimen Identification Specimen Identification Classification CuPI Cc GRAIN SIZE DISTRIBUTION 3335 Arctic Blvd Ste 100 Anchorage, AK 99503 Telephone: 907-564-2120 Fax: 907-564-2122 Project: Cox Residence - North Woods Unit 4 B17 L7 Client: ANTHC Project Number: 18-021-58.4 US _ G R A I N _ S I Z E 1 8 - 0 2 1 - 5 8 . 4 L O G S . G P J H D L M O D I F I E D . G D T 7 / 1 0 / 2 3 I Municipality of Anchorage Page ~ of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: !~"'¢ O"~ 1 PID Number: O21 O~ ~ ~ Nar. e: ~ ~~ Wastewater System: ~ New ~ Upgrade AddressYO~ ~O~9~I Cku~ ABSORPTION FIELD Phone: ~% No. of~edrooms: ~ Deep Trench U Shallow Trench ~Bed ~Mound ~Other Total Depth from original grade: LEGAL DESCRIPTION SoilRating: O,~ GPD/Sq. Ft. V~ 4~ ~ Lot: ~ BIock:~ ~ ~ ~Oo~Subdivisi°n: ~ Depth~l~to pipe bottom/~fr°m~-°riginalCrade: Ft. Gravel depth beneCho~ pipe Ft. TownshiB:~[~. Range:~t ~ Section~ ~ Fill~l~added abovet o°riginal~ grade:o~ Ft. Gravel length: ~O Ft. WELL: Q New ~ Upgr~ Gravel width~, Numbe~lines: Distanc~%tweenlines: Ft, Ft. Classificati°n (Private' A'B'C): ~ tal D . Cased To: Total absorp~t~a: Pipe materiah t. Ft. SQ. Ft. Drillor: Static Water Levoh Installo[: Dato installoO: Yield:/ Pump Set at: Casing Height Above Ground: TAN K GPM Ft. Ft. SEPARATION DISTANCES ~Septic ~ Holding ~ S.T.E.P. TO Septic Absorption Lift Holding Public/Privat~ Man~ Capacity in gallons: Material: Number of Compartments: Surface Water +t~' +~' ~¢' LIFT STATION Li~e ~O' ~¢ +~, S ze nga one: Manufacturer: Foundation ~ ~. ~ "Pump on" level at: ~evel at: High water alarm at: Curtain ~u~ ~ ~ctri~l I~p~ti Drain ~ ~' ~O1 ~ ~' p one performed by: Remarks: 5~ I~L~ ~ ~~ BENCH MARK Location and Description: Assumed Elevation: " J OO¢ Fl, ,~ENGINEER'S SEAL Department of Heal.nd Human ServiceS approval ¢,r~ ~"~*~ ", '"'S0/ 72-013 {Rev. 9/91) MOA 25 Permit No. '~0~1 Page Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: PID No.: 72-013 A I2/91 ~ MOA 25 ENC-.~IEER'S SEAL MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW930391 DESIGN ENGINEER:CONSTRUCTING ENGINEERS, INC. OWNER NAME:NORTHWOODS INC OWNER ADDRESS: 0510644800088 DATE ISSUED: 9/22/93 EXPIRATION DATE: 9/22/94 PARCEL ID:05106448 LEGAL DESCRIPTION: NORTH WOODS UNIT IV BLK 17 LT 7 LOT SIZE: 29081 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS ISSUED BY: ~---'~'~-~ / HENRY WILSON 9601 BUDDY WERNER DR.: ANCHORAGE, AK 995]6 (907) 346-2000 Constr En !ngineers rveyors CHARLES A. LANDERS HC83 BOX 192-A, MYRTLE DR. EAGLE RIVER, AK 99577 (907) 694-9098 September 13, 1993 Municipality of Anchorage On-Site Services Division PO Box 196650 Anchorage, AK, 99519 Attn: John Smith, P.E. re: Submittal for Septic Permit, L7 B17 Northwoods Sub Gentlemen: Attached are plans for a new wastewater absorption system for the subject lot. The lot previously had a soils tests performed which is the basis for the design. Although we were not the engineers which performed the test, the test did meet the MOA requirements for water monitoring. The soils test does not indicate a presence of ground water, but the owner is wishing to be most conservative, and considering the history of ground water issues in the subdivision, he wishes to install a bed system. Although the normal requirements for area around the test hole require 60' diameter coverage, and since the test holes indicate consistent soil characteristics on the lot, we ask for approval as shown on Drawing 93-Sl-09-6. If you have any questions, please contact me at 694-9098. Respectfully submitted, Chuck Landers Constructing Engineers i ABSORPTION SYSTEM DESIGN SITEPLAN--PROPOSED ABSORPTION SYSTEM DETAILS OF BED ABSORPTION SYSTF, M LOT 7t BLOCK 17t NORTI'IWOODS SUB~ PREPARED FOR: PAUL MEYERS PO BOX 670485 CHUGIAK, AK, 99567 688-1236 SCALE: l" = 100' DRA%4N BY CAL CONSTRUCTING ENGINEERS346-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, Al(, 99516 9-13-93 D~ING # ~-S1-~-6 ABSORPTION SYSTEM DESIGN DETAILS dv~ v v ~1 ABSORPTION AREA CALCULATIONS: 3 Bedrooms x 150gpd/bedroom = 450 gpd (soils rating : 0.5 gpd/sf) 450 gpd % 0.5 gpd/sf = 1000 sf area Bed design: use 24'W x 42'L bed (minimum) w/ 4 ea 4" perf pipes @ 6' centers, each 36' in length. IMPACT ON ADJACENT LOTS: This lot is served by a public water system. The proposed absorption system is located such that there is no adverse impact to any adjacent lot. There are no wells, private or public, within 200' of the proposed system. DESIGN DETAILS--PROPOSED ABSORPTION SYSTEM BED ABSORPTION SYSTEM LOT 7v BLOCK 17v NORTHWOODS SUB, ~" PREPARED FOR: PAUL MEYERS PO BOX 670485 CHUGIAK, AK, 99567 688-1236 NOT TO SCALE DRAWN BY CAL CONSTgUCTING ENGINEERS346-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, AK, 99516 9-13-93 DRAWING # 93-S2-09-6 5/8" Rebar set or found each corner unless otherwise shown / / ! hereby certify that a survey of Lot~? BLock 17~OR~WOODSSubdivJsion was made on SEPTEMBER 8, 1993 and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on property Lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as shown hereon. It is the responsibility of the owner to determine the existence of any easements/ covenants or restrictions which do not appear on the recorded subdivision plat. Under no circumstances should any data hereon be used for construction or for establishing boundary or fence lines, Dated in Anchorage, AK, SEPTEMBER 13, 1993 CONSTRUCTING ENGINEERS PLOT PLAN/LOT SURVEY 9601 Buddy Werner Dr Anchorage, AK, 99516 346-2000 694-9098 SO.El'= ~0' SURVEYOR'S SEAL i MON 1 ~, : '~ I CiEOI~Ci£ I,~ I LMOTH Munlelp~qllly e! AnGhorage DEPARTMENT OF HEALTH & HUMAN SERVICES 826"L" Street, Anchorage, Alaaka 89502.0650 SOILS LOG '-" PERCOLATION TEST ' ..... SLOPE $~T~ PLAN 6 ? 8 10 11 .12 13 14 15 17 q$ 19 "I -/ WAS GROUND WATER IF Y~S~ Al' WHAT Net OmP MUNICIPALITY OF ANCHORAGE 'AA,I Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-064-48 1. GENERAL INFORMATION Expiration Date: /0 —'3 - Z —,12Z-- Complete 2Z Complete legal description NORTH WOODS UNIT 4 BLK 17 LT 7 Location (site address) 23409 Blue Skies Drive Chugiak AK 99567 Current property owner(s) ANDREW TAYLOR Day phone (210)723-6239 Mailing address Real estate agent 23409 Blue Skies Drive Chugiak AK 99567 Jean Santiago 2. TYPE OF DWELLING: Fx� Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 Day phone 907.414.0179 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic El Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5Oc/ -7 1 Date of Payment Receipt Number 002-0 Oy6 '/ 7 d COSA # O SC 2 0131 3 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Eklutna Engineering, LLC Phone 907.355.9820 Address 19162 Mountain Rd Chugiak AK 99567 Engineer's Printed Name Curtis Townsend, PE ��®�®,��ate 7/7/2020 6. DSD SIGNATURE System #1 Approved for - bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms .�� OF ��•; ............. �ur1b T • • Date ��'��' •. No. CE 11904 AW ��pROfEgSiON� a-�- bedrooms, with the following stipulations: \ZY OF �A,, WATER AND J WASTIE_V_"ATER oz^ JJ �J��iIyF�T SERU�G�� �,.. i By: ��� Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic c Advisory Well Flow Advisory Other Ann�'C �8 4, COSA Checklist blue sheet Legal Description: NORTH WOODS UNIT 4 BLK 17 LT 7 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) In. Date of flow test for COSA Static water level eginning of test ft. Comments P BLIC WATER B. TANK DATA Age of tank(s) 27 years Tank type/material septic Isteel Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping 7/25/2019 Parcel ID: 051-064-48-000 Structure served by this system Well production at time of lesC gpm Water sto=cted olume gallons Well dis'coliform test? ❑ Yes ❑ No Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance complete Age of lift station y Lift station material Comments. D. ABSORPTION FIELD DATA Which system tested (date installed) 1993 Adequacy test date 6!29,2020 ❑ ALL standpipes present per record drawing Results Q✓ Pass For 3 bedrooms Total measured depth from grade 4.29 ft (max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade 4.25 ft (min) Water added 968 gal ❑ N/A — pressurized field 1/4 New depth in ❑ Monitor tubes go to bottom of effective. If not, state 240 depth into effective 1/2" Elapsed time min p ❑ Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate ' 450 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) _ Gallons introduced gallons If yes, enter date Comm ents/Deficiencies:_NORTHWEST AND SOUTHEAST CLEAN OUTS MISSING. THERE ARE STILL (2) OTHER CLEANOUTS PROVIDING ACCESS COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0✓ Yes Community Sewer Manhole/Cleanout > 100' 1`7 Yes if No ft M Yes if No Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25'F,7( Yes if No Absorption Field on Lot > 100' r✓ Yes if No ft Holding Tank > 100' [71 Yes if No Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' Yes if No P/ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F71 Yes if No ft ❑✓ Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 121 Yes if No ft Surface Water > 100' ft ft ft ft ft Q✓ Yes if No ft Property Line > 5' 0✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' F� Yes if No ft Private Wells > 100' F✓ Yes if No. Water Main > 10' 0✓ Yes if No ft Community Wells > 200' Q✓ Yes if No Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ED Yes if No ft If absorption field is under driveway comment below Property Line > 10' 1✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' Water Service Line > 10' 171 Yes if No ft Community Wells > 200' Surface Water? 100' Q Yes if No ft F. ENGINEER'S COMMENTS Monitor tube doesn't extend fully into effective depth so it is difficult to accurately determine condition of bed. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet OF A�'..4k ..:'. .......... • Curtis To. vi 9 y� • Date CE Jig ®FlopROFES510\�P��`. ft ft [✓ Yes if No ft Z Yes :if No ft ENGINEER'$ Septic 'Tank Advisory Certificate of On -Site Systems Approval #OSC 201313 Subdivision: North Woods #4 Blk 17 Lot 7 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 27 years old. Typical replacement costs range from $8,000 to $11,000. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 year old steel tank MAY look like. ��� � Mailing Address P O Box 196650, * Ahchorage, Alaska 99519 6650 *,www muni org x MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY O~'~ O~-A~ROVAL FOR A SINGLE FAMILY DWELLING Par, c~el I.D. # ~ HAA# 1. GENERAL INFORMATION Complete legal description L. Location (site address or directions) Property owner Mailing address Lending agency Mailing address Agent Address Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~ TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: ing to the legality and status of system. If community well system, provide written confirmation from State ADEC attest- TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. ~ 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my inves.tigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ¢---~5J¢¢~' Address A-r,.c.J~,'~e%,- - Engineer's signature DHHS SIGNATURE Approved for ,-~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date ~;The MUnicipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority :Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA #21 Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: L '7- ~ 13~ ]v~v-~w oo<~< -i~ A, Well Data Parcel I.D. Well type Log present (Y/N) Total depth Sanitary seal (Y/N) If A, B, or C, attach ADEC letter. ADEC water system number Date completed Driller Cased to Casing FROM WELL LOG Wires properly prote AT 'ION Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM g.p.m. Septic/holding tank on lot Absorption field on lot Public sewer main Sewer service ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout. Petroleum tank WATER RESULTS: Coliform Date of sample: Nitrate Other bacteria Collected by: B. SEPTIC/HOLDING TANK DATA Date installed ~ o//~,> Cleanouts (Y/N) High water alarm (Y/N) Date of pumping Tank size ~ ooc~ Compartments Z Foundation cleanout (Y/N) ¥ Depression (Y/N) /',/~ Alarm tested (Y/N) ~ ~ ~ - ~"~'~ ~.- Pumper SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot ~ ~ On adjacent lots ~ ~oo' Foundation 7_.7-' To property line doc>' Absorption field ~ Water main/service line '~'~ Surface water/drainage 72-026 (3/93)' Front CONTINUED ON BACK PAGE Co LIFT STATION Date installed Manufacturer Manhole/Access (Y/N) Sudace water Size in gallons ~e Vent (Y/N) "Pump on" level at /~ I at High water alarm level ~ J t~.....~ e. cycres~e~ts tested Meets MOA electrical codes (Y/N) SEPARATION D~TION TO: Well o~ On adjacent lots D. ABSORPTION FIELD DATA Date installed ~ o )95 Length 5 o' Width Total absorption area Dateof adequacy test ~J Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) Soil rating (GPD/FF) o. ~' System type '~ ~'~' Gravel thickness I o._ Total depth Cleanout present (Y/N) ~' Depression over field (Y/N) Results (pass/fail) ~,J ,/~ for IV ~ After test ~/~ If yes, give date, Bedrooms SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot To building foundation On adjacent lots Surface water +Z.oo On adjacent lots Property line To existing or abandoned system on lot Cutbank -~,5o ' Water main/service line Driveway, parking/vehicle storage area -{--~ Curtain drain E. ENGINEER'S CERTIFICATION I cer~fy that I have checked, verified, or conformed to all MOA and HAA guidelines in effect Signature Engineer's Name Date HMFee$ ~,~0~' ~ Date of Payment Receipt Number 72-026 (3/93)* Back Wa ver Fee $ Date of Payment Rece pt Number