HomeMy WebLinkAboutT12N R3W SEC 33 LT 45D-1On -Site Water and/or Wastewater System
Permit
Permit Number: OSP161044
Tax Code Number: 01819222000
Work Type: SepticTank
Permit Effective Dates: June 14, 2016
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
to June 14, 2017
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: T12N R3W SEC 33
Site Legal Address: T12N R3W SEC 33 LT 45D-1 G:3034
Owner/Address: LEVIS PHILIP G & JUDITH
PO BOX 110134 ANCHORAGE AK 995110134
Site Mailing Address: 2940 E 142ND AVE, Anchorage
This permit is for the construction of:
N Disposal Field Y Septic Tank N Holding Tank
Lot Size in Sq Ft: 20167
Total Bedrooms: 4
N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received B
Issued By:
y
Date:
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department _ Phone: 907-343-7904
Development Services Division Fax: 90,7-343-7997
On -Site Water &Wastewater Program U® TTAI
ON-SITE SEWER/WELL PERMIT APPLICATION S MAR 14 2016 16
Gretchen 5tuller
Parcel I.D. 018-192-22
Property owner(s) Pholip & Judith Levis Day phone
Mailing address P.O. Box 110134, Anchorage, AK 99511
Site address 2940 E. 142nd Avenue
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T12N, R3W, Sec 33, Lot 45D-1
Lot Size 20,167 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
ig all that apply)
-
Absorption Field
❑
Initial ❑
Single Family (SF)
_X1
(w/wo ADU)
Septic Tank
Upgrade f
Duplex
❑-
(D)
Holding Tank
❑
Renewal F-1Multiple
Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Dis tance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
of property owner or authorized
Permit/Rush Fees: 4 a15
Date of Payment: 31101J6
Receipt Number: bsp 1 3s�' /
Permit No. r�5P1&1ej(
Permit App_-' :- :L�c�
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Pannone Engineering Services «c
Steven R. Pannone, Principal
Registered Professional Engineer
,E-mail: steve@paneneak.com
March 11, 2016
Subject: T12N, R3W, Sec 33, Lot 45D-1 -
Septic Tank Replace Permit Request
Design Narrative
This is a design narrative for a permit to install an upgrade 1500g S.T.E.P. tank to be issued for this
property. The existing tank is collapsing. It will be decommissioned per code. Currently the lot is
developed. The proposed system will utilize a replacement 1500 S.T.E.P. tank that will be connected to the
existing drain field. This lot and lot 45C-1 to the west are served by a class 'C' well PWSID: 217437. The
well is located ±115 feet from the existing tank, which ADEC approved at the time of the well registration.
PES contacted ADEC drinking water and talked to Justin Fenzl who stated that as long as we send them
the record drawing for their file after the tank has been replaced the distance approval will continue to
stand. The new tank will maintain this separation distance. The remaining surrounding wells are private.
There are no wells within 100 feet of this system.
1. Upgrade Tank Design.
a. See Sheet 1 of the design package.
2. Surface Water: There is no surface water within 100 feet of the proposed septic tank. The proposed
septic tank upgrade will maintain at least 100 feet from all surface water and drainage ditches.
3. Topography: The existing topography slopes from northeast to southwest at approximately 4% in
the vicinity of the system.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no surrounding wells within 100 feet of the proposed septic location.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
PROVISION
ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS. _
2. SCOPE OF WORK: INSTALL NEW 1,500g S.T.E.P. TANK AND DECOMMISSION EXISTING TANK PER CODE.
� m SAA
-3' RESERVE EAS
WELL (E)
142ND AVENUE
INS W� W
i
W-
DRAIN FIELD (E)
,ems
SEPTIC AREA (E)
MAA
OUS E 45D1
HOUSI z S
w /w
\� COLLAPSING 15008 S.T.E.P. TANK (E)
DECOMMISSION PER CODE
_ _INSTALL 1500g S.T.E.P. TANK (P)
10' UTILITY EASEMENT WITH DOUBLE CLEAN OUT BEFORE TANK
\—MAINTAIN 115' TO CLASS 'C' WELL
CLASS 'C' PWSID: 217437
WELL (E)
PWSID: 217437
�✓ i �i
DESIGN PARAMETERS
INSTALL NEW TANK
NO.BEDROOM:4
TANK SIZE: 1,500g S.T.E.P.
USE:
NEW 1,5009 S.T.E.P. TANK
NOTES:
TANK REPLACE
DRAWN BY:
DRM
PLAN
LEGEND
—W— WATER LINE/
WELL RADIUS
SS — NEW SEPTIC
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
T12N, R3W, Sec 33, LOT 45 D-1
PHILIP & JUDITH LEVIS
2940 E. 142ND AVENUE
ANCHORAGE, AK 99516
MA
ABBREVIATIONS
FC FOUNDATION CLEAN OUT
T# TANK CLEAN OUT NO.
C# CLEAN OUT NO.
DCO DOUBLE CLEAN OUT
OG ORIGINAL GRADE
E EXISTING
OF Date
.A..C,qia/10/zoie
���, '•�.9 �� Scale
*. *t✓/ 1"=50'
.... .. .. ... P.I.D. NO
-192-22
StevenR. Pannone j PERMIT N0.
CE8149 .•.�� „co,,,,,,,,,,,,
1 OF 1
THE STATE
"'ALASKA
'irrovERNOR BILL r4'it'AF.I{F R
Pannone Engineering Services
P.O. Box 10 0217
Anchorage, Alaska 99510-0217
Department of Environmental Conservation
Division of Water
Wastewater Discharge Authorization Program
555 Cordova Street
Anchorage, AK 99501
June 13, 2016
Re: Anchorage -T 12N, R 3W, Sec. 33, Lot 45D1 -Waiver of Separation Distance to a Class "C" Well in South
Anchorage-t112EC-Plan-Tracking_N--umber16_D_W-umber_W-165
Dear Mr. Pannone,
On January 10, 2016 the sample results arrive to complete the waiver request for the home at 2940 E
142D Ave. here in Anchorage. The waiver computation was checked and matches ones done earlier for
this lot.
The current sample for nitrate as nitrogen is listed as 0.452 mg/1. Which indicates that the concern is
lessening at this source.
Based upon the engineers submittal and his recommendation and his concern for public health not
four bedroom house is within accepted engineering practice,
A waiver as requested by the engineer is established. This is an older site with activities not expected to
increase in use for the four bedroom home. Should it be found that the site conditions endanger public
health or are a public health concern, the waiver will be rescinded.
This approval does not imply the granting of additional authorizations nor obligate any state, federal or
local regulatory body to grant required authorizations.
Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18
AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with 18 AAC
15.185. Informal review requests mum be delivered to the Division Director, 410 Willoughby Avenue,
Suite 303, P.O. Box 111800, Juneau, Alaska 99801, within 15 days of receiving the decision. Guidance
information on the informal review process may be found at bU:/fwww.dec.state.al,.us/commisb/`Review-
Guidance.hirn, Adjudicatory hearings requests must be delivered to the Commissioner of the
Department of Environmental Conservation, 410 Willoughby Avenue, Suite 303, P.O. Box 111800,
Juneau, Alaska 99801, within 30 days of the decision. 1f a hearing is. not requested within 30 days, the
right to appeal is waived.
Thank you for your cooperation. If you have any questions please do not hesitate to contact me at 269-
7519.
Respectfully,
Environmental Engineer
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPDSAL SYSTEM AND/OR WELL INSPECTION REPORT
PHONE
NEW
MAI LING ADDRESS
LEGAL DESCRIPTION
LOCATION
[~q. capac,tvmgaHonsl -IF~OMEMADE: DISTANCE TO' ~ell
Well
DISTANCE TO: L~e,g
No. of lines ~1~ of each line
Top of tile to finish g~ade
NO. OF BEDROOMS
PERMIT NO.
Liquid depth
PERMIT N~,
PERMIT NO,
/
Distance between lines
Total lengd~ of lines Trencl~ width
inches
Material beneath tile Total effective absorption area
inches
D0pth ~, ~' ~
Crib depth
Bu Id ng foundation
- .~O~-
Well
DISTANCE TO: I~-'~!
Depth Driller Distance to lot line
Building foundation Septic tank
DISTANCE TO:
Nearest lot line
OTHER
PIPE MATERIALS
SOl· TEST RATI '
DATE LEGA·
Department ~. Health and Environmental nrotection
825 Street, ~chorage, AK. .,501
264-4720
* * * HANDWRITTEN PERMIT * * *
Permit
JA~-.,~'~/OR ON-SITE SEWER PERMIT L~/f¢¢~¢/~¢-
Location:/~9~ ~$--~/ Phone Nu~er: r~-/~SZ
Type of Soil ~sorption System Is:
Trench: Drainfield: Seepage Bed: ~ Holding Tank:
Maximum Number of Bedrooms: J~ Soil Rating(sq.ft/br) ~
The Required Size of the Soil Absorption System Is:
DEPTH ~-~ LENGTH ,-~ ' . GRAVEL DEPTH _~ WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
* * REQUIRED SEPTIC(HOLDING) TANK SIZE =/~x~-~ GALLONS * *
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
* * * TWO(2) INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final inspection and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance frem a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31~ 1 9 * *
I certify that:
(1) I am familiar with the requirements for on--site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site
the residence is remodeled to
Signe~: ~ , I ..... ~
A ~
sewer system may require enlargement if
include mor~ that 3 bedroom.
SWP/024(1/81)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
1
( SP/S~~,)
2
3
9
10
11
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
12
13
IF YES, AT WHAT
DEPTH?
S
14
15-
16-
17-
18-
19-
20-
Reading Date
TEST RUN BETWEEN
Gross Net
Time Drop
Net Depth to
Time Water
(minutos/inch)
~ FT
COMMENTS )~(~ ~¢/~ ' / ~]~,
PERFORMED BY: L RO.~¢~ CERTIFIED
17~o~ st Cq~o~q
D A 1' E~?fi~/f'
ALASKA F dlROFIITleFITAL COFITROL SE huICe$, IFiL
~n~ineerinq $ ~nuironmcnlol $1udics
January 16, 1985
MUNICIP/\LITY OF ANCHORAQ[
D[PT. OF t lEALTFt &
ENVIRONMENTAL PROFECTION
Mr. Keith Bandt
Department of Health & Environmental Protection
825 L. Street
Anchorage, Alaska 99501
JAi,t 2,1,985
RECEIVED
Subject: Ti2N R3W Sec. 33, Gov. Lot 45
Dear Keith:
The attached as-built for the septic system on T12N R3W Sec
33, Gov. Lot 45 shows the dimensions of the bed to be 32' x
38'= 1216 sq.ft. However, the pipe separation in the bed is 6
feet which gives a total of 30 ft. The length is 38'. Thus
the absorption area is 30 ' x 38' = 1140 sq.ft. The required
area is 196 x 1.5 x 4 ~ 1176 sq.ft. Th% error was caused by
measuring between each pi~e rather than center to center and
letting the side wall be too far from the pipe.
In our opinion, the excavated area of the bed is the deciding
factor. Our opinion is based upon the fact that the gravel
under the pipe is very permeable and offers little or no
resistance to the flow of effluent. All'the effluent will
flow directly to the soils interface unless the bed is not
level. In that case, some ponding will occur until such
irregularities are filled. At that point, the effluent will
spread evenly across th~ excavated area and percolate in the
soil.
While we are very careful, for the most part, Co ensure
center-to- center distances are used, this one slipped
through.
to the smell area involved, 36 sq.ft of
We
recommend
that
due
absorption area, field that the system.be accepted as sufficient to
meet the needs of the home. It ~s ~n unnecessary expense to
require the be exposed and the 36 sq.ft of absorption
area added. Also, due to the excavation techDiques driving
on/near the~ bed, and other factors, it is highly probable more
harm than good would occur from Juch addition.
Approved by: Sincerely,
~L~.y~. Reid Jr.,* PhD, PE Ron ~E. Godden
Presi~nt Environmental Engineer
Operation Manager
1200 UJcsl 33rd Auenue, Suile [~, Anch0ro% AIosb 99503,(907) 561-5040