HomeMy WebLinkAboutT12N R3W SEC 33 LT 207ANCHORAGE AREA BOROUgh'TI
DJ:rARTMENT OF ENVIRONMENTAL OUALf~
3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
MAILING
NAME ~///P/~/~' ~--~-~/~ ADDRESS
LOCATION /~/~-:-~//'~ /~'~j~("~..d~. LEGAL DESCRIPTION
SEPTIC TANK: /f/~7-~ .-~'.~'~' __/f~r~ ~,~.C/~-/7/,,/.~ ~.~/~)
DISTANCE FROM WELL /'P~ /
LIQUID CAPACITY/'~/"--/~;'~ GALLONS.
NUMBER OF d~
MATERIAL --~.-~'~--~"- COMPARTMENTS '
~P,.P-~d~- ~P~-~ ~-'~ '~"~'~J~/~ LIQUID
INSIDE LENGTH INSIDE WIDTH DEPTH
SEEPAGE SYSTEM: SEEPAGE PIT: .~)K'/./J~7.'f/~-~ --//~/~'~'~-~ P~P~'
NUMBER OF PITS
LINING MATERIAL
NEAREST LOT LINE
OUTSIDE DIAMETER / OR WIDTH ~, LENGTH ~ DEPTH
~/'~/z~'~-~-~/~z~/~--~ DISTANCE FROM WELL ./~-?/) / BUILDING FOUNDATION~''
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SQ. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELt ~ ~~NEAREST LOT LINE
NUMBER OF LINES ./'~DISTANCE BETWEEN LINES \ TRENCH~
ABSORPTION AREOLA SQ. FT. LENGTH OF EACH LINE
TOTAL LENGTH
, OF LINES , .
IN, TOTAL EFFECTIVE
DEPTH: TOP OF TILE TO FINISH GRADE
DEPTH OF FILTER MATERIAL BENEATH TILE
IN. ABOVE TILE--
WELL:
LOT LINE
.~'//~ ~;~ DISTANCE FROM
TYPE ,..,~,~,~/z/,,~..?~.~"' , DEPTH ~' / , BUILDING FOUNDATION
p~/~. NEAREST ~ SEPTIC ~ SEEPAGE
~ ' , SEWER LINE~ ~ ,TANK /~ , SYSTEM
WATER
_SAMPLE /;f~ , NEAREST
/~/~"(~ OTHER '~'.Y ,/'/~, .
· CESSPOOL~'~'',/-d~/'~'~/-~, SOURCES'"c~:'#'J/
DISTANCES:
DATE
DIAGRAM OF SYSTEM
APPROVED ~'~' ~
G.A.A.B.
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMIT NO.
MAIL]N(; ADDRESS . PHONE
NAME OF APPLICANT
INSTALLATION LOCATION ~/>
TYPE AND $]ZE Of faCILiTY TO be SERVED
FINANCED THROUGH TO BE INSTALLED BY
. , /~
SOIL TEST RESULTS ~ ~
FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION,
SEPTIC TANK SIZE /'~//~///~/ TYPE ~r~_~ SEEPAGE AREA SIZE ~//~ TYPE
DIAGRAM OF SYSTEM
MINIMUM DISTANCES, REQUIREMENTS
SEPTIC TANK TO SEEPAGE PIT WALL. /~/~/
DRAIN FIELD
TO NEAREST LOT LINE.
SEPTIC TANK,
· SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
___, SEEPAGE Pit
DRAIN FIELD
CAST IRON ]NTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION-
I CERT)FY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO, 28-68 AND THAT THE ABOVE
i ~ DATE RECEIVED
· INSPECTION APPOINTMENTS
TIME TIME
,NSPECTO i NSPECTtI:~/ ~\" I NSPECT¢~ /
) DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
825 LStreet-Anchorage, Alaska 99501 AU~ 2 ~ 9~0
ENVl RON~ENTAL SANITATION DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be proce~ed. Please allow ten (10) days for processing.
1. PROPERTY OWNER PHONE
MAI LING ADDRESS
PROPERTY~NT {If different from above) PHONE
PHONE
5. LEGAL DESCRIPTION
6. TYPE OF RESIDENCE
,~ SINGLE FAMILY
[] MULTIPLE FAMILY
7. WATER SUPPLY
INDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTI LITY
NU~MBER OF~BEDROOMS
~ One [] Four [] Other
~ Two [] Five
./~ Three [] Six
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available,)
8. SEWAGE DISPOSAL SYSTEM
~ INDIVIDUAL/ON-SITE**
[] PUBLIC UTI LITY
YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS ·
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[~ COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVIDUAL/ON -SITE DATE INSTALLED
[~PUBLIC UTILITY ,;;-~,~ ~ ~
Connection Verified INSTALLER
[]Septic Tank or []Holding Tank
Size: I~-~ (~ If Tank is homemade SOILSRATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPT,ON AREA MATER,AL
5. COMMENTS
/
~ONDITIONAL APPROVAL (letter must~npany certificate)
72-010 (Rev, 6/79)
October 2, 1980 R&M No. 051001-70
Mr. Ronald K. Russell
Post Office Box 10-1521
Anchorage, Alaska 99511
Re:
Adequacy Test on Existing Sanitary Sewer System; Consisting of a
Septic Tank with a Seepage Pit; T12N, R 3W, Sec. 33, Lot 207 N~&S~
Anchorage, Alaska
Dear Mr'. Russell:
Per your request of August 28, 1980, Dan Cooper of R&M Consultants con-
ducted a test of the sanitary sewer system on the above described property.
The test indicates acceptance rates determined under conditions at the time
tested. Actual system performance over long periods of time depend on
factors which cannot be evaluated by this test thus our office cannot
warrant the suitability or fitness of the system for either an extended period
of time or for user demand in excess of the expected flow noted herein.
Factors affecting system performance include:
O
O
Actual use demand on the system;
Fluctuations in groundwater levels;
Physical conditions of the septic system, leach field, trench or
seepage pit and soil.
It should be noted that while a septic tank and seepage pit disposal system
is one of the most reliable methods of sewage treatment and disposal it is
nearly certain that the leach field or seepage pit will fail sometime during
the useful life of the structure. Studies indicate leach fields, trenches and
pits have a life expectancy of ten to twelve years under optimum conditions.
All septic systems have a finite hydraulic loading capacity which can be
expected to decrease with time.
Mr. Ronald Russell
.October 2, 1980
Page. 2
Because the house on the lot is occupied, we assume that the seepage pit
was at its normal degree of saturation. During this test the liquid level in
the septic tank was monitored as water was added to the system. The
measurements are summarized in the following table:
FIRST DAY
Date: September 29j 1980
Remarks:
No standpipe to seepage pit.
Water Added To Septic Tank
Liquid Level Measurements Taken From Top Of Standpipe
TIME GALLONS TOTAL LIQUID
ADDED GALLONS LEVEL
2:45 0 0 3:55
2:57 50 50 3:45
3:08 50 100 3.4
3:21 50 150 3.35
3:33 50 200 3.3
3:45 50 250 3.25
3:55 50 300 3.2
4:05 50 350 3.15
4:15 50 400 3.1'
4:25 50 450 3.1'
4:35 50 500 3.05'
Remarks: Standpipe has no cap. This could cause freezing of the system
during cold weather due to induced draft through the building vent stacks.
Mr. Ronald Russell
October 2, 1980
Page ,3
Date: September 30, 1980
SECOND DAY
GALLONS TOTAL LIQUID
ADDED GALLONS LEVEL
10:32 0 0 3.45'
10:43 50 50 3.45'
10:54 50 100 3.4'
11:03 50 150 3.35'
11:13 50 200 3.3'
11:23 50 250 3.3'
11:34 50 300 3.2'
11:44 50 350 3.2'
11:54 50 400 3.15'
12:04 50 450 3.1'
12:14 50 500 3.05'
Date: October 1, 1980
THIRD DAY - Septic Tank Level 3.45'.
The meter used during the test was a Rockwell 5/8" standard water meter
which had previously been calibrated by R&M Consultants, Inc.
The total daily load for the three bedroom residence is four-hundred fifty
(450) gallons; surge capacity is three-hundred sixty (360) gallons.
The Municipality requires the system to accept a surge capacity of 80% of the
total daily load at a rate of ten (10) gallons per minute, tested for a two
day period and to accept the total daily load in twenty-four (24) hourS.
Mr. Ronald Russell
Oct.ober 2, 1980
Page ,4
Failure Criteria is as follows:
1. Water rises excessively in septic tank at or before 80% of total
added.
2. Effluent overflowing system.
3. Water level does not return to within one inch of static level.
load
The first day of testing, the system accepted five-hundred (500) gallons in
one-hundred ten (110) minutes which is more than 100% of the total daily
load.
The second day of testing, the system accepted five-hundred (500) gallons
in one-hundred two (102) minutes which is more than 100% of the total daily
load.
The static water level on the third day had returned to within one-inch of
the initial static water level.
We therefore conclude that the system is disposing of effluent at an adequate
rate for a typical three bedroom residence.
We appreciate this opportunity to be of service to you. please contact us if
you have any questions concerning this test or if we can be of additional
service.
Very truly yours,
R&M CONSULTANTS, INC.
Richard S. Giessel
Senior Engineer
DC: RSG/jatb
GREATER ANCHOPAG.~ AREA BOROUGH
Department of Environmental quality
3500 Tudor Road, Anchorage, Alaska 99507 279-8686
Date Received
Date of Ins~ection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Prooertv ~ner: ~~
Legal Description: .~~/~. /~. 3~,
Phone
Phone
Type of Facility to be Inspected:
Number of Bedrooms: ~
Well Data:
A. T~e
C. Constructf on/~,~'~/~,z~/z~~
B. Depth 0~,/-/~
_ D. Bacterial Anelysis
Or ' s.
7. Sewage Disoosal System:
O. Septic Tank: 1.
D, Seepage P&%: 1. S~ze 2.
E. Disposal Field:
8. Installer -------
Manufacturer~'~.~-~..J3'~
Material ~/-,6~-~'
Total Length of Lines ~/~ .
Distances:
/ /
Area ~/~
Absorption
Sewer
Lines
Other
Contamination
B. Foundation to Septic T~nk
C. Absorotion Area to Nearest Lot Line ' --
'*R%quest for Approval of ~,ldivfdua] Sewer & Water Facilities
Page Two
Approval Valid for One Year From Date Signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request' for appreval to be a true
and accurate representation of the subject sewer and water fac~!tties located at:
Signed Dage