HomeMy WebLinkAboutUS SURVEY 3200 LT 2U55 #3200
Lot 2
#090-041-04
Municipality of Anchorage
Community Development Department Page 1 of 3
On-Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSPXXXXXX PID Number: 090-041-04 ❑ New ❑ Upgrade
Name:
Marilyn Lybarger
ABSORPTION FIELD
❑ Deep Trench ❑✓ Shallow Trench ❑ Bed -❑ Mound
Address
177 Comfort Ln. Indian, AK 99540
❑ Other
Phone
Number of Bedrooms -
Soil Rating
Total depth from original grade
-
4
- 0.8GPD/SF
- 4Ft.
LEGAL DESCRIPTION - -
Depth to pipe invert from original grade
- - 2 Ft.
Gravel depth beneath pipe -
2Ft.
Subdivision Block Lot
US Survey #3200 - - 2
Fill added above original grade
0 Ft
Gravel length - -
53 (2) Ft.
Township Range Section
-
Gravel width
5Ft
Beds: Number of Lines
N/A
Distance between lines
N/A Ft
SEPARATION DISTANCES
- To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
-)5 1S'F
2
10.1 Ft.
Well
107.8
108.2
N/A
N/A
91.9
TANK I] Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Existing
Capacity
I 1,5000al.
Surface Water
123.5
103.9
N/A
N/A
Material
Number of compartments
Lot Line
80.1
11.5
N/A
N/A
Steel
2
NA
Foundation
10.3
38.0
N/A
N/A
LIFT STATION
Manufacturer
Capacity -
Curtain Drain
50+
50+
N/A
N/A
Gal.
RemarksThis record drawing is based of the 4/27/2016 -
Pump on level at -
in.
Pump off level at
in-1
High water alarm at
in,
survey as-built. This record drawing is also for the
purpose of documenting the currently undocumented -
Pump make and model
Electrical Inspections performed by
system. Drain field covered with 2" of insulation.
ISJSWIM
PIPE MATERIAL House to tank Tankto
Installer '
drainfield
v'r MIMN
- Drainfeld CO/MT-
Inspector l/�N `LN�
BENCH MARK (Assumed elevation) 'POOR
Inspection „ -
1
Location and description - - -
dates: : O� rn _
Man door threshold by garage -
3rd
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
Conditional Approval: Date
•��everi '•l5annorae f/
` 81?
Approv k,w�_ Date
Inspection Report _1-1-12.doc
inn' s1
OFFSET
CAM
LOT 2
M M
07
A
B
Ti
13.4
43.9
T2
13.8
41.0
C1
93.4
90.5
M1
92.0
89.5
C2
100.9
94.0
M2
100.8
93.5
C3
54.4-
40.0
- C4 -
68.4
49.6
inn' s1
OFFSET
CAM
LOT 2
M M
07
fl �,
TRUE NORTH SCALE 1"= 50'
1,500 GAL STEEL
SEPTICII TANK (E)
WELL E
11.5
c7
1
110.4 c2 w
(AIV D%E c4 M2
\
11
2 EACH SHALLOW TRENC
53'L x 5'W x 2'ED x 4'TD
NOTES:
RECORD- DRAWING OF
EXISTING UNDOCUMENTED
DRAWN I NJC
SITE PLAN
PANNONE ENG SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
US SURVEY #3200, LOT 2
MARILYN LYBARGER
177 COMFORT LN.
INDIAN, AK 99540
7/6/2016
Scale
1"=50'
P.I.D. NO
X90-041-04
PERMIT NO.
OSPXXXXXX
Sheet
2 OF
4BR
SFD 1
WELL E
B
108.2
-
DRIVEWAY
fl �,
TRUE NORTH SCALE 1"= 50'
1,500 GAL STEEL
SEPTICII TANK (E)
WELL E
11.5
c7
1
110.4 c2 w
(AIV D%E c4 M2
\
11
2 EACH SHALLOW TRENC
53'L x 5'W x 2'ED x 4'TD
NOTES:
RECORD- DRAWING OF
EXISTING UNDOCUMENTED
DRAWN I NJC
SITE PLAN
PANNONE ENG SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
US SURVEY #3200, LOT 2
MARILYN LYBARGER
177 COMFORT LN.
INDIAN, AK 99540
7/6/2016
Scale
1"=50'
P.I.D. NO
X90-041-04
PERMIT NO.
OSPXXXXXX
Sheet
2 OF
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 4(600 gpd)
TANK SIZE: 1,500g
SOIL RATING: 0.8..GPD/SF
AREA ROD: 750 SF
SYS. TYPE: SHALLOW TRENCH
5'W x 2'ED (RF=0.7)
LENGTH: 106 LF x 5/0.7 =757 SF
USE:
2 EACH 53LFx5'Wx2' E.D., 4.0' TO
TOTAL AREA: 757 SF
NOTES:
RECORD DRAWING OF
EXISTING UNDOCUMENTED
SYSTEM
I NJC
SITE PLAN
PROFILE
ABBREVIATIONS
2" R.I.
TEST HOLE
WELL RADIUS (P)
PROPOSED
- FILTER FABRIC
EXISTING
NEW SEPTIC Co
CLEAN OUT NO..
4" 0 DRAIN PIPE
MONITOR TUBE NO. ,
TYP
-
DRAIN ROCK 6" ABOVE PIPE INV
GEORGE PUTNAM
TH#1 3/22/1994
2.0
OR
- -I.o
1 it �InE=Tr�YE
EL. as a-. yl EL. esa
-
SM
DRAIN ROCK
-4.0
EL 8L9
El 8]8
�
SM
-s.0
SM
-10
elx
NO GROUND WATER MONITORED
-
SECTION
z
0Q
7 0
m
0 0
z
0
ow
w w IC
o
L`
wPIPE
z
wK
6"
3
EL. lal;-
E INVI
"PIPE
---I
96 9I:
-1EL
1,500 GAL o
EL 9e.z EL a9.9
wase
t,
TANK (E)
E<. aza DRAIN ROCK
53.0 OF EACH
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 4(600 gpd)
TANK SIZE: 1,500g
SOIL RATING: 0.8..GPD/SF
AREA ROD: 750 SF
SYS. TYPE: SHALLOW TRENCH
5'W x 2'ED (RF=0.7)
LENGTH: 106 LF x 5/0.7 =757 SF
USE:
2 EACH 53LFx5'Wx2' E.D., 4.0' TO
TOTAL AREA: 757 SF
NOTES:
RECORD DRAWING OF
EXISTING UNDOCUMENTED
SYSTEM
I NJC
SITE PLAN
PROFILE
ABBREVIATIONS
WATER LINE / - TH
TEST HOLE
WELL RADIUS (P)
PROPOSED
- (E)
EXISTING
NEW SEPTIC Co
CLEAN OUT NO..
MT
MONITOR TUBE NO. ,
TYP
TYPICAL
PANNONE ENG SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
US SURVEY #3200, LOT 2
MARILYN LYBARGER
177 COMFORT LN.
INDIAN. AK 99540
Date
7/13/2016
Scale
1"=50'
P.I.D. NO
-690=041-04
PERMIT NO,
OSPXXXXXX
Sheet
3 O 3
Mtmicipalfty of Anchorage
Department of Health and Human. Services
825 " L" Street 44
Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650
Mayor
343-4744
May 18, 1995
Marilyn R. Lybarger
HC 52 Box 8802
Indian, Alaska 99540
Subject: US Survey 3200 Lot 2
Permit #SW940132, PID #090-041-04
The subject permit, issued May 18, 1994 by this office for a
single family well and/or on-site wastewater system, has
expired as of May 18, 1995.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as -built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
cerely,
am Cross, P.E.
rogram Manager
On-site Services
enc: Copy of Permit
cc: Lantech
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW940132
DESIGN ENGINEER:LANTECH
OWNER NAME:LYBARGER MARILYN R
OWNER ADDRESS:HC 52 BOX 8802
INDIAN, AK 99540
PARCEL ID:09004104
LEGAL DESCRIPTION: US SURVEY 3200 LT
LOT SIZE: 98175 (SQ. FT.)
NUMBER OF BEDROOMS: 5 THIS PERMIT: 5
2
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED: 5/18/94
EXPIRATION DATE: 5/18/95
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH THE REVISED
DESIGN SUBMITTED_9Qi 5/10/94.
RECEIVE
ISSUED
DATE: ` J
DATE: / /
RECEIVED
Permit No. MAY 121994 Pageof
W.O. 94L1118
Municipality of AnchoraWnicipality of Anchorage 4/8/94
DEPARTMENT OF HEALTH AND ftV"th,L ftTIr"?i,a�VIces Date
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchorage, AK 99519-6650• Tel: 343-4744
On—Site Wastewater Disposal System/Well Inspection Report
Legal Description: LOT 2 U.S.S. SURVEY 3200 PID No.
SITE NARRATIVE
LOT 2 U.S.S. Survey 3200 is bordered by TRACT B-1 (undeveloped) to the north, U.S.S. 1868 (undeveloped)
to the south, LOT 1 U.S.S. Survey 3200 (residential) to the east, and LOT 3 U.S.S. Survey 3200 (residential)
to the west.
The lot topography is general characterized by sloping in a south easterly direction with a drainage stream
flowing through the property and exiting on the south west side. Lot 1 has a well house located approximately
35' from the property line. Lot 3 appears to have no conflicting on—site services or topographical features.
The site parameters considered for the development of this lot are identified on the Site Plan.
The client's proposed lot development is a 1200 square foot addition increasing their total number of bedrooms
to five (5). The existing well and unrecorded septic system are inadequate and will be abandoned and removed.
Two test pits were dug on 3/22-23/94. A perched water table was encountered in test pit #2 ®8.0'.
Monitoring tubes were placed in each test pit and rechecked on 3/25 & 4/2. Test pit no. 1 generally consisted of
SANDY SILT with GRAVEL (SM) to approx. 4' below the existing ground surface underlain by SANDY GRAVEL with SILT
to approximately 8'. Fractured rock with sand and silt was encountered to the end of the test pit, approx. 10'.
On 4/2/94 1" of water was recorded in the monitering tube, approx. 10' below the existing ground surface.
This test pit had a percolation rate of 7 minutes per inch between 4' and 5' below the existing ground surface.
The second test pit
generally consisted of SILT with SAND and GRAVEL
(ML)
to approx. 8.5' below the existing
ground surface with
a percolation
rote of 45 minutes per inch between
4.2'
and 4.7' below the existing ground
surface. The percolation
test hole
was saturated overnight and the test
was
run on 3/23/94.
The obsorbtion field
size is based
on 15 min/inch. Replacement field size
is
based on 45 per inch.
The monitering tubes were checked on 5-6-94 and no water was observed.
■
LAND & CONSTRUCDDN SUR4£vORS-PLANNERS-ENGINEERS
440 WEST 9ENSCN BLVD. Y 103
ANCHORAGE, ALASKA 99503 (907) 562-5291
EBL COMP Fie I....
Permit No. Pageof
Municipality of Anchorage W.0, 941_1118
DEPARTMENT OF HEALTH AND HUMAN SERVICES Date
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, AK 99519-6650• Tel: 343-4744
On—Site Wastewater Disposal System/Well Inspection Report
Legal Description: LOT 2 U.S.S. SURVEY 3200 PID No.
en
C-
01
01
SITE PLAN
RECEIVED
MAY 12 1994
OT Z NEIGHBORS
L WELL HOUSE Municipality of Anq*
Rl OMO' ept. Health & Human S
USS 3200 /
/
/
EXISTING WELL INSTALL GREASE TRAP
1OD' RADUIS IN KITCHEN WASTE
TO BE ABANDONED LINE. \
1
PROPOSED WELL / /
1/
100' RADUIS /1 e G
HOUSE
/ I /
/ IAITI
DDD/ME E
PROPOSED
WELL LOCATION
\ l;
\\\ i SGRA ( ROAD \ _ EXISTG //iNSrn��TRod/ //
\ 7S 9'p01, E SYSTEM / srFvFk
USS A 8680P�D II \ \ \ DRAINAGE
UNOEVE STREAM —
\ DRAINAGE STREAM /
\100' RADUIS /
LEGEND: SET FIND
\
5/8"RB W/CAPD 5/8" RB ®
3.25" AL.MON. MONUMENT &
HUB & TACK O
\
OVERHANG- ®
— _ —
' •
CLEANOUTS
WOOD DECKS-
CONCRETE- 0
MONITOR TUBES
ASPHALT- =
SEE CROSS
GRAVEL- [
SECTION DETAIL
SEPTIC STANDPIPES- QS
(���
CONTOUR
INTERVAL: 2
WATER WELL-
APPRX. TEST PIT 1
LAND & CONSTRUCTION SURVEY S-PLANNERS-ENGINEERS/�
—
LOCA110N
4 NEST BENSON BLVD. A 103
SCALE.
1 — 50
DRAINAGE
ANCHORAGE, N.ASKA , 99503 (907) 562-5291
rage,
arvice
s
CD
o Lo
n �
)) O
O M
100'+ CONTRACTOR '0
€TELD VERIFY DISTANCE
`CA 1
�9
ASSUME 0.0' ELEV
_ AT STATION i*ODS
�
\
W
4 P�� OFq�gsa®
y*'••gTH •�•�®
>i
?Y �GREG6IGVM. PUTN AMS
is ••� CE 7892 � •
o® dere �•••••••••�®\�
�� °'�rofesslo�o♦�
TE ,`®®®cas♦
EBE CCNP 11 1080.ONG
Permit No. Pageof
Municipality of Anchorage W.O. 941_1118
DEPARTMENT OF HEALTH AND HUMAN SERVICES Date 5/10/94
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, AK 99519-6650• Tel: 343-4744
On—Site Wastewater Disposal System/Well Inspection Report
Legal Description: LOT 2 U.S.S. SURVEY 3200 PID No.
MANIFOLD
PIPE
INSTA> -m4v. .'C
MONITOR TUBE —
PERFORATED IN
`-R $l3on�PIST1W 0.Ylord
5' WIDE
SWALLOW
TRENCH
FINISH GRADE
SOND
SOLID
PIPE
MANIFOLD 4" PERFORTATED PIPE
PERF PIPE 24" MIN,
PIPE PERF DOWN
HOLES DOWN
LAID LEVEL
SEPTIC
.
___
I
ilkllY7i
CLEANOUT: AT
MONITORING
2
BEGINNING OF TRENCHES
TUBE- CAPPED
AND AT EACH END 10'
PERFORATED IN SEWER
ROCK, SOLID ABOVE.
3/4" TO 1.5'
SEWER ROCK
66.5'
PLAN VIEW NTS
3/4" - 1.5"
SEWER ROCK
PROFILE (TYP)
MONITOR TUBE - CAPPED.
PERFORATED IN SEWER
ROCK, SOLID ABOVE.
BACKFILL
2" INSULATION
6" GRAVEL
I 4" PERFORATED PIPE
LAID LEVEL WITH
HOLES DOWN AND
I
CAPPED ON END.
SIDEWALL OF
TRENCH
3/4" - 1_5"
SEWER ROCK
5.0'
B'
WATER
TABLE
IMPERMF_ABLE
2" BLUE LAYER
�- BOARD
INSULATION
END CAP
24'
ASSUMPTIONS: RECEIVED
1. FIVE (5) BEDROOMS
2. ACCEPTING SOIL RATING: MAY 12 1994
190 SO. FT./BDRM
3. NO GROUND WATER AS OF 5-6-94 Municipality of N<t�:n.:
REQUIRMENTS: Dept. Health R Humil." S�
1. 1500 GALLON SEPTIC TANK
2. ABOSORPTION BED
TOTAL AREA: 950± SO. FT.
3. PLACE BOTTOM OF ABSORPTION BED AT 4.0' BELOW
EXISTING GROUND SURFACE, INSTALL 2" BLUE FOAM BOARD
INSULATION AND USE 24" MIN. OF NATIVE SOIL BACKFILL.
4. WASTE LINE FROM KITCHEN INTO GREASE TRAP IS OPTIONAL.
TYP. CROSS
SECTION NTS
_ANO & CCNSTRUCVON SURVEYORS-RUNNERS-ENCNEERS
440 WEST BENSON BLVD. R 103
ANCHORAGE. ALASKA 99503 (907) 562-5291
'o -M6 A I2ry11 Hw n
E9E CPAP Eia_ IC80.OXC
MONITOR TUBE —
PERFORATED IN
IUTS - CAPPED
ROCK. SOLID ABOVE.
FINISH GRADE
SOND
PIPE
PERF PIPE 24" MIN,
HOLES DOWN
1500 GAL
SEPTIC
___
TANK
Rnon
3/4" - 1.5"
SEWER ROCK
PROFILE (TYP)
MONITOR TUBE - CAPPED.
PERFORATED IN SEWER
ROCK, SOLID ABOVE.
BACKFILL
2" INSULATION
6" GRAVEL
I 4" PERFORATED PIPE
LAID LEVEL WITH
HOLES DOWN AND
I
CAPPED ON END.
SIDEWALL OF
TRENCH
3/4" - 1_5"
SEWER ROCK
5.0'
B'
WATER
TABLE
IMPERMF_ABLE
2" BLUE LAYER
�- BOARD
INSULATION
END CAP
24'
ASSUMPTIONS: RECEIVED
1. FIVE (5) BEDROOMS
2. ACCEPTING SOIL RATING: MAY 12 1994
190 SO. FT./BDRM
3. NO GROUND WATER AS OF 5-6-94 Municipality of N<t�:n.:
REQUIRMENTS: Dept. Health R Humil." S�
1. 1500 GALLON SEPTIC TANK
2. ABOSORPTION BED
TOTAL AREA: 950± SO. FT.
3. PLACE BOTTOM OF ABSORPTION BED AT 4.0' BELOW
EXISTING GROUND SURFACE, INSTALL 2" BLUE FOAM BOARD
INSULATION AND USE 24" MIN. OF NATIVE SOIL BACKFILL.
4. WASTE LINE FROM KITCHEN INTO GREASE TRAP IS OPTIONAL.
TYP. CROSS
SECTION NTS
_ANO & CCNSTRUCVON SURVEYORS-RUNNERS-ENCNEERS
440 WEST BENSON BLVD. R 103
ANCHORAGE. ALASKA 99503 (907) 562-5291
'o -M6 A I2ry11 Hw n
E9E CPAP Eia_ IC80.OXC
RECEIVED
Permit No. Pageof
MAY 12 1994 W.O. 931_1118
Municipality of Anqiorage
unrgi 1' ¢
DEPARTMENT OF HEALTH AD.��m�RCES Date
ENVIRONMENTAL SERVICES DIVISION
erwces
P.O. Box 196650 Anchorage, AK 99519-66500 Tel: 343-4744
On—Site Wastewater Disposal System/Well Inspection Report
Legal Description: LOT 2 U.S.S. SURVEY 3200 PID No.
NOTES:
1 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ON-SITE WASTEWATER TREATMENT AND
DISPOSAL REGULATIONS OF THE EPA DESIGN MANUAL.
2 INSTALL NEW 1500 GAL SEPTIC TANK AS SHOWN ON THE DRAWINGS. RECORD INLET AND OUTLET
ELEVATIONS OF THE TANK. TANK SHALL BE PLACED ON UNDISTURBED NATIVE SOIL. PLACE OUTSIDE
PROTECTIVE WELL RADIUS.
3 ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO ITS INCORPORATION
INTO THE SYSTEM.
4 CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATER WAYS,
SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING
SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. NOTIFY THE ENGINEER OF ANY OBSERVED
CONFLICTS PRIOR TO CONSTRUCTION.
5 NOTIFY THE ENGINEER 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF TWO
INSPECTIONS ARE REQUIRED. THE FIRST INSPECTION SHALL BE OF THE SUBGRADE, PRIOR TO PLACING
SAND FILETER. THE SECOND INSPECTION SHALL BE AFTER THE PLACEMENT OF GRAVEL, DISTRIBUTION
PIPING, STANDPIPES, TANK, AND OTHER COMPONENTS AS SPECIFIED.
6 CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED -LINED, AS -BUILT DRAWINGS SHOWING ALL DATA
AS SPECIFIED IN THE ON-SITE WASTEWATER TREATMENT AND DISPOSAL REGULATIONS WITHIN 30 DAYS OF
THE FINAL INSPECTION. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE
AS-BUILTS SHALL BE USED TO DOUBLE-CHECK THE ENGINEER'S INFORMATION PRIOR TO SUBMITTAL TO DHHS.
7 STAKE ALIGNMENT OF SYSTEM WITH MARKERS SHOWING THE PROTECTIVE DISTANCES FROM WELLS AND
OTHER BODIES OF WATER PRIOR TO BEGINNING INSTALLATION.
g A SOILS LOG MUST BE PROVIDED OF THE TRENCH WALLS AND BED OF SUBSURFACE DISPOSAL FIELD IF THE SOILS
DIFFER FROM CONDITIONS UPON WHICH THE PERMIT WAS BASED.
9 ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE
ENGINEER.
10 SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MIN. SLOPE, AND 3:1 MAX SLOPE, AND IN SUCH A MANNER THAT
PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN
SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION.
11 ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR
ENGINEER -APPROVED EQUAL. .♦e®®®®`,
12 MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, F:OFA:�4
TRASH AND CONSTRUCTION DEBRIS. ®,`P•• ON
13 RECORD THE FINISH GROUND ELEVATION OVER TOP OF BED. / * :/4 �7.�L,1�7O
LAND k CONSMUCi SURVEYMt PLMNMS-ENQNEERS
440 WEST BENSON BLVD. $ 103
ANCHORAGE, ALASKA 99503 (907) 562-5291
ESE CMP rne. IDSD.DWG
• ae
PERFORMED FOR
LEGAL
®'POgE IiJ�ERr °SEB. •��+
RECEIVED ,�: ?s�
Municipality of Anchorage /�Y
DEPARTMENT OF HEALTH & HUMAN SERVICES, 2 1994 r'
825 "L" Street, Anchorage, AlaskanD 9MOOrOFWY Of Anchora ''�? °SEC R'
SOILS LOG — PERCOLAWN IYW & Human Se 'c r'°° CE 7892
aP.r' DATE PFRFOR14ED:
2 V.S,S SotJey 32-v° Township, Range, Section:
(FEET) I D. pkv iL SQ" I J
wf� rowed
'�rr�a.2 rirgbn'� c S
W" Y C-K-ztje I
w;'wx s',4 (sm
W; [4.1,
G Af () �vST Q r'r'
COMMENTS
SLOPE
bit t FLAN
WAS GROUND WATER I
ENCOUNTERED? NO
S
IF YES, AT WHAT L
DEPTH? O 20
P
E
Depth to Water After p
MonitodngT Date:
n
PERCOLATION RATE 7 (minutes/inch) PERC HOLE DIAMETER 8
TEST RUN BETWEEN )' FT AND 5 FT
PERFORMED BY: CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
+� Municipality of Anchorage �y
DEPARTMENT OF HEALTH & HUMAN SERVICES �•� ' • •'
T 825 "L" Street, Anchorage, Alaska 99502-0650
Pt' co • M. PUT?4AM e �?
SOILS LOG — PERCOLATION TESTS CE > 78s2
PERFORMED FOR: DATE PERFORP4ED: �� �h •Ri
LEGAL DESCRIPTION: LoA 2 0. 3.5. Suroev g2DO Township, Range, Section:
DEPTH SLOPE SITE PLAN
(FEET) INTI—I
3-
6-
II
6 C�L>
7
9
r�
11
12
13
14
15
16
17
18
19
20
>z^� 4 511 �I '2�[tro
Jt¢ WAS GROUND WATER
ENCOUNTERED? des
S
T WHAT (orf- L
J P
E
r ae f ;
Date: % qy
IF YES, A
DEPTH?
Depth to Wale
Monitoring?
PERCOLATION RATE �- (minutes/inch) PERC HOLE DIAMETER
TESTRUNBETWEENJ=-FT AND �� FT
COMMENTS Ilona-6J`Fn rl W%I!-G,' °P- 0.,F , AI,� -)Y-IC-r,C"
�j ,
I
PERFORMED BY: 1 CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
II
MAMpAMIT 3)M11j17CD 'U0M7'&KQ
1201 Ramona St. 99515 ANCHORAGE* ALASSSA
,344-7714 wclsl -11 S aLc--�
(0gL)-oj4\-01A
SIX INCH WATER WELL DRILLED ----------OUT TO THE DEPTH OF 205 feet.
DRILLED AT THE RATE OF 524.0) PER FOOT. Steel casing seated out to 4J ft.
PROPERTY
OWNER
''1r• Tom Lybarger
653-7726
'afl�l-Y
-
DRILLER
Bernie
Claus of Rampart
Drilling Works.
WELL LOG:
0 - 17'
Coarse
gravel & small boulders. 30$ silty material.
17 - 29' CingLomerate. A broken weathered fractured rock material.
29 - 40' Bedrock. A fairly soft sedimentary rock. Casing driven to 40 ft.
40 - 205' Bedrock. A very hard sedimentary rock. 1/2 gpm water yield
showing by 65 ft. From thin fissures & cracks in the bedrock. By 165 ft
a total of 2 gpm was showing out of granular type rock. From 173 to 176 ft.
an additional 2 gpm was showing coming out of a porous type rock. At this
depth, 4 gpm was produced at short duration pumping (30 minutes) then the
production dropped down to about 3 gpm. By 205 ft., (196-199) production
increased to a total of steady 8 gpm. (Two hours of pumping.) During short
term pumping (30 minutes) gpm indicated a steady ten.
A 1/2 horse submersible pump should be installed at the 160 ft. level. But
a 3/4 horse pump, if used, should be installed at about 180 ft. 25 ft. off
bottom. The water has been pump almost crystal clear, but will pump a slight
amount of silt in the first two hours, on installation of sub pump.
Water recovery is back up to within 35 ft. of surface.
No mob or demob cost. This Well paid for in full with 30 ft. no charge.
COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING.
This Water Well guaranteed & certified by Rampart Drilling.
WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF ----------
THANK YOU VERY MUCH.
BERNIE CLAUS OF RAMPART DRILLING WORKS
DATE June 17, 199h
SERVICE CHARGE 0 F lyn% PER MONTH WILL BE ASSESSED ON PAST DUE ACCOUNTS.
7/0 (�\O t Ce
(11;
;'0RUV1
Municipality of ranchorUL z I 201 On -Site Water and Wastewater Progr(907)343-7904 f r Ac
5�
Certificate of On -Site Systems Approval
Parcel f:D. 090-041-04 - Expiration Date: l
1. GENERAL INFORMATION
Complete legal description US Survey #3200, Lot 2.
Location (site address) 177 Comfort Lane
Current Property owner(s) Marilyn R Lybarger Day phone
Mailing address
Real Estate Agent
552 W Tam Oshanter Drive. Pheonix, AZ 85023
2. TYPE OF DWELLING:
x1 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
0
Individual
0
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request
Received by: Date: -711 Y l d10 ( (0
COSA to be released to the engineer, unless otherwise requested by the engineer, -
COSA Fee $ Waiver Fee $
Date of Payment 1 AL1 ifo Date of Payment
Receipt Number u tRl�1 Receipt Number
COSA# Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown b€low, kverify that my4n4eStibatlon, Used on procedures outlined
in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater
disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply
and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at
the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA COSA
guidelines and regulations. The reported results describe the performance of the system under the conditions encountered I the time of the test,
and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend ,nn 1F1E•local oil';
condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the syst*
4m. ese yoriditions
are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do At gbarahiee future_,
performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot$rovide any warranty
for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed
above.
Name of Firm Pannone Engineering Services LLC
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
6. DSD SIGNATURE
System #1 Approved for `1 bedrooms
System #2 Approved for bedrooms
Disapproved
Phone (907) 272-8218
Date 7/11/2016
S}even R. ririorie
CE -8149 i
Conditional approval for bedrooms, with the following stipulations:
By: 1` Original Certificate Date: / 7� [ -C
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet f c
If more than 1 septic system is on the lot:
COSA Checklist # -L_of +_
Structure served by this system
Certificate. of Ori=Site Systems Approval Check itt
Legal Description: US Survey #3200, Lot 2.parceLlDc 090-041-04
A. WELL DATA
Well type Private If A, B, or Cprovide PWSID # Well Log (YM) Y
Date completed 6/17/94 Sanitary seal/N Y -
(Y ) _ Wires properly protected (YIN)
Total depth 205 ft. Cased to 40 ft. Casing height (above ground)
FROM WELL LOG AT INSPECTION
Date of test 6/17/94 4/20/16
Static water level 35 ft 33
W611 production 8 g.p.m. 7.9+ 9 P m-
WATER SAMPLE RESULTS:
Coliform Ne9 colonies/100 mL Nitrate -0.110 mg/L
Arsenic NU ug/L Date of sample: 6/24/16 Collected by: PES
B. SEPTIC/HOLDING TANK DATA
TankType/Material Septic/Steel Unknown
installed
Tank size 1500 gal Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (YM) Y Depression over tank (Y/N) N High water alarm( (Y/N) N
Dateofpumping t V ��) Pumper 7 -f �ii�i (S�A �J
C. ABSORPTION FIELD DATA
Unkng" z 0:8 g.p.d/sf
Date installed Soil rating (g:p.d./ft2 or ft /bdrm) System type Shallow Trench
Length 53 3.7 ft. Width id�� ft. Gravel below pipe 2 ft
Total depth_ ft. , absorption of lea flz Monitoring tube Y— Depression over field
.4120/20x1: Y
Date of adequa y tot + - %Results (Pass/Fail) For 4_: badrooms
Fluid depth in absorption field before test 0/ Q in. Water added:687 gal. New depth 0 0 in.
Elapsed Time;, 90 min: Final fluid depth 0 ,O in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at_
Datum
Size in gallons - Manhole/Access (Y/N)
in. "Pump off' level"at in. High water alarm level at in.
_ Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES,
WELL ON LOTTO: '
Septic tank/Ilft station on lot 100+ On adjacent lots 1-00+
Absorption field on lot 100+ On adjacent lots 100+
Public sewer main 75+ Public sewer manholelcleanout 100+
Sewer /septic service line 25+ Holding tank "0+ -
Animal containment areas 50+ Manure/animal excrete storage areas 100_ -+
SEPTIC/HOLDINGTANK ON LOTTO:
Building foundation 5+ Poperty line 5+ Absorption field 5+ -
Water main 10+ Water service line 10+ Surface water 100+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Property line 10+ Building foundation 10+ Water main 10+
10+ 100+
Water Service line Surface water Driveway,,parking/vehiclestorage-
Curtain drain 50+ Wells on adjacent lots 1.00+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections' and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date,'
Engineer's Printed Name Steven Pannone
Date 7/1,1 L2016
COSA canary sheet -2-6-1 5.doc
o 0
FIND ALUM PIPE
UTILITY POLE J79*50'00""
- 330.Op
FND BRASS OAP
UTILITY POLE
+� Lot 2 _
USS 3200 r
O N /
2 /
� w
oON,
IN /IN
oPq0
/ LOG HOUSE
I Z Well
'''
0 EATING ME
® RISERT 1100' RADIUS
/
PORCH ?<4, re25•�y EMENT
PAD
/VN71�ed1 b \ +02.4'
'19,00"W GRAVEL DRIVEWAY I
1337 ®"--R�Rs
i \ EXISTING WELL \
-\
100' RADIUS
FND REIRM
W/ CAP
DRAINAGE
STREAM /
100'
RADIUS / GRAPHIC SCALE
a u sDMMMMMMMO
so 120
( IN FEET )
I hereby certify that I have surveyed the
following described property. "LOT 2, USS
3200' Anchorage Recording District, Alaska,
and that the improvements situated 'thereon
are within the property lines and do not
overlap or encroach on the property lying
adjacent thereto except as indicated hereon,
that no improvements on the property lying
adjacent thereto encroach on the premises
in question and there are no roadways,
transmission lines, or other visible
easements on said property except as
indicated hereon.
28 Apr 2016
FOR: PARAGON PROPERTIES
dfaska06 (907) 242-5287
�r aonsDve[iax su7vcys
c7.. {?41'86t SN203 SCALE DATE DRAWN BY
Axborlpe, Akye O0.I
P0344-D50Ci 1" = 60' 4/27/2016 AMV