ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191062 I PID Number: 090-022-06
Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑■ Upgrade
Name:
Terra Nelson
ABSORPTION FIELD
E] Deep Trench 0 Shallow Trench E] Bed ❑ Mound
Address
PO Box 483 Girdwood AK 99587
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
(907) 202-3101
3
4.0 GPD/SF
+2 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+2.6 Ft.
Gravel depth beneath pipe
0.6 Ft.
Subdivision Block Lot
US Survey 3202 22
Fill added above original grade
5.3 Ft.
Gravel length
25 Ft.
Township Range Section
Gravel width
5.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
125 Ft
1
Ft.
Well
>100'
>100'
N/A
N/A
>25
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding Other
Manufacturer
Orenco / Advantex (FAP)
Capacity
11500 Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
Fiberglass
2
NA
Foundation
>10'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
Remarks Trench is insulated.
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
Wilco Contractors
Drainfield D3034. CO/MT
Inspector J. Williams
BENCH MARK (Assumed elevation) 100 ft
Inspection ection 1s' 4/1/19 d 4/2/19
Location and description
2
3'd 4`h
Bottom of siding.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
Conditional
OF
Approval: Date T
.
see hP Vt_V,2 T_r,-c�-7 o/
9th ••s.....�
U/
q / ✓
^C( IrC2X�l /'YLU (,(/j d
... :. ............
' ;-
G. L Jap �LGGrC �., l�(J/'/��2�:
®.uu....um..I..nu..........unu.....un
��n'; MICHAEL E. ANDERSON f ii a
% No. CE-4381 �� w
4 C�
Approved �i�R Date 5 /� X0:2 7
�
C" •°°•.°° 7/9/19 .°••' J�5
�e t01VPROFESS���®+��
iaNcl�uvi 1 r UPUI i_V- i- 1 c.uuc
US SURVEY 3202 LOT 22 - BIRD CREEK PARCEL
PERMIT # OSP191062
/
/
50' BLM RESERVATION FOR ROADWAY
AND PUBLIC UTILITY PURPOSES
RECORDED IN VOLUME 150, PG 309
-,LPT 2
\
\ T CENTEkLINE STREAM
LO23
\ ! \ a
\ ALTERNATE SITE
v
\ OVERHEAD POWER LOT 22 /t ��t
\ f r t 2 °' -1-- /
25' LQIgG x 5' WIDE x 0:5' /
Ey�FFECTIV�/E°DEPTH
\ .FABSORPn ION TRENCH,_
100rSTREA
.SET -BACK'
r
r —
_, ........ .., .� / r 001 ! ` r
r. Myr nnhz X500 GA1 AdUAYVTEX
t 'r'_ 'r''1 A-RTA`NK'v�i/Ak,X POD
ter` •'r
N.
— EXTEL`1T'C'7� FTLLi ter.,. it lgyl _ _ _ _ \
vtv _r _ ` ✓iii /�r'' t /2�ELL
aoM H
RADIUS
LOT 21
'EXISTING WELL
L v.
RIGHT-OF-WAY EASEMENT
\\ \\ � ` `\�\moo\ \` RECORDED IN DOCUMENT
v v { vvvvvv " ANO. 2006-036798-0
\ ` LOT 1
ENGINEERING
49th
MICHAEL E. ANDERSON
No. CE -4381 ,e• �q, 719/19 .•'°
���e
• i'
\
t
e
PLAN AS -BUILT
0 100 200
1 EN FEET
1"=100'
20S�
21.9
14.6
MH1
35.6
19.9
LEGEND
CO — CLEANOUT
2CO — DOUBLE CLEANOUT
FCO — FOUNDATION CLEANOUT
FS — FLOW SPLITTER VALVE
MH — MANHOLE
MT — MONITORING TUBE
SV — SEPTIC VENT
TH — TEST HOLE
67.3
66.7
US SURVEY 3202 LOT 22
PERMIT # OSP191062
�— 70.0 FINISH GRADE
MOA APPROVED FILTER SAND
2" INSULATION
67.3
--66.7
62.9 (West) 63.7 (East)
64.7 ORIGINAL
GRADE
25'
GROUNDWATER @ 62.2 3/12/19
53.7
PSE, OF
e fiAw
d•, 49th '
r
MICHAEL E. ANDERSON
PROFILE AS -BUILT ����=.. No. CE -4381 r
4!25!19• ••°�
¢NGINEENINC
(NO SCALE)
,f VESSICt�®®
N40° 40' 00"E 330.00'S40° 40' 00"W 159.22' (C)
N
4
9
°
0
1
'
0
0
"W
3
3
0
.
0
1
'N40° 40' 00"E 161.05' (C)N40° 40' 00"E 330.00'N
4
9
°
2
0
'
0
0
"W
3
3
0
.
0
0
'
N
4
9
°
2
0
'
0
0
"W
3
3
0
.
0
0
'
S
EW
A
R
D
H
I
G
HW
A
Y
C
E
N
T
E
R
L
I
N
E
1
1
4
.
2
'
SHED
1
7
1
.
9
'20.2'5
0
'
B
L
M
R
E
S
E
R
V
A
T
I
O
N
F
O
R
R
O
A
DW
A
Y
A
N
D
P
U
B
L
I
C
U
T
I
L
I
T
Y
P
U
R
P
O
S
E
S
R
E
C
O
R
D
E
D
I
N
V
O
L
U
M
E
1
5
0
,
P
A
G
E
3
0
9
CONNEX
CENTERLINE
STREAM
14%5%CHICKEN COOP
LOT 14
U.S.S. 3680
LOT 15
LOT 13
LOT 23
LOT 21
LOT 2
LOT 22
U.S.S. 3202
50' BLM RESERVATION FOR
ROADWAY AND PUBLIC
UTILITY PURPOSES
RECORDED IN VOLUME 150,
PAGE 309
AT MH
MH
24.2'40.2'20.1'16.0'
24.2'4.1'NOTES:
1.THIS DRAWING SHALL NOT BE MODIFIED FOR USE AS A PLOT PLAN WITHOUT
THE EXPRESSED WRITTEN CONSENT OF LCG LANTECH.
2.SNOW AND ICE MAY CONCEAL MINOR SURFACE FEATURES.
3.THE PLAT FOR LOT 14 DOES NOT FORM A CLOSED FIGURE, THE DIMENSIONS
SHOWN HERE ARE THE EXTENSION OF THE SIDE LOT LINES TO THE CENTERLINE
OF THE PLATTED SEWARD HIGHWAY PER U.S. SURVEY 3680. THE ACTUAL
DETERMINATION OF THE SOUTH WESTERLY PROPERTY LINE (BORDERED BY THE
SEWARD HIGHWAY) IS BEYOND THE SCOPE OF THIS SURVEY.
4.LOT 14, U.S. SURVEY 3680 IS SUBJECT TO BLM PATENT RESERVING
RIGHT-OF-WAY PER BOOK 703, PAGE 775.
5.THERE IS AN AGREEMENT TO PROVIDE SHARED ACCESS RECORDED IN
DOCUMENT NO. 2014-027845-0.
LOT 22, U.S. SURVEY 3202 &
LOT 14, U.S. SURVEY 3680
SEPTIC STANDPIPE
WATER WELL
FENCE
LEGEND:
DRAWN DATE:
DRAWN BY:
SCALE:
CHECKED BY:
5/7/2019
SC
ADS/SC
1" = 60'
PLAT:
WORK ORDER:18152
USS 3202 AND USS 3680
FB/PG: 811/68-69
GRID:SW4760
LEGAL
ORDERED BY:TERRA NELSON
EXCLUSIONARY NOTE: IT IS THE OWNERS' RESPONSIBILITY TO DETERMINE
THE EXISTENCE OF ANY EASEMENTS, COVENANTS, RESTRICTIONS OR
RIGHT-OF-WAY TAKINGS WHICH DO NOT APPEAR ON THE RECORDED
SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION, FOR ESTABLISHING PROPERTY
LINES, OR FOR PLOT-PLAN PURPOSES.
250 H Street
Anchorage, Alaska 99501
Survey Department
Phone: 562-5291
Mainline
Phone: 243-8985
AECC 668
COMPUTED (C)
HOUSE DETAIL
SCALE: 1" = 20'
EXISTING HOUSE
(SEE DETAIL)
RIGHT-OF-WAY EASEMENT
RECORDED IN DOCUMENT
NO. 2006-036798-0
UTILITY
POLE
(TYP)
DESCRIPTION:
EXISTING
HOUSE
AT - ADVANTEX TANK
MH - MANHOLE
SURVEY CERTIFICATION: LCG LANTECH, INC HAS CONDUCTED A PHYSICAL
SURVEY OF THE PROPERTY AS SHOWN ON THIS DRAWING AND CERTIFIES
THAT THE IMPROVEMENTS SITUATED THEREON EXIST IN THE LOCATIONS
AS SHOWN AT THE TIME OF SURVEY.
AS-BUILT
H`c%PALITT MUNICIPALITY OF ANCHORAGE
...\OF ill l r
On-Site Water&Wastewater Program ��� `M S
PO Box 196650 4700 Elmore Road
044/
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997
/ http://www.muni.org/onsite
Department
�NCMONAVE
On-Site Wastewater Disposal System Permit
Permit Number: OSP191062 Effective Date: 3/27/2019
Work Type: Septic Upgrade Expiration Date: 3/26/2020
Tax Code Number: 09002206000
Site Legal Address: US SURVEY 3202 LT 22 T1 ON R1W SEC 10 G:4760
Site Mailing Address:
Owner: NELSON TERRA B Lot Size in Sq Ft: 108900
Design Engineer: FORGE ENGINEERING Total Bedrooms: 3
This permit is for the construction of:
El Disposal Field El Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
1. In order to close out this permit, the well permit (OSP151193) shall be closed out by providing the following:
a) Well log
b) Pump install log
c)Water sample results for total coliform, nitrates and arsenic.
2. The drainfield shall be entered at the midpoint, as shown on the site plan, to comply with AMC
15.65.355H.2, allowing two foot separation to seasonal high groundwater.
n 1
Received By: ( � f � �/' � i Date: 1
Issued By: R Date: 31 Ir
MUNICIPALITY OF ANCHORAGE
•
. it
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On-Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 090-022-06
Property owner(s) Terra Nelson Day phone (907) 202-3101
Mailing address PO Box 483 Girdwood AK 99587
Site address NHN Seward HWY. Bird Creek, AK
Legal description (Sub'd., Block & Lot) US Survey 3202 Lot 22
Legal description (Township, Range & Section)
Lot Size 108,900 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field ❑x Initial ❑ Single Family (SF) ❑X
(w/wo ADU)
Septic Tank ❑X Upgrade ❑X
Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
2 nnlino hlo T Ai inininol (`nr•Icc-14/L,f2,Q,
V v
(Signature of property owner or authorized agent)
Permit/Rush Fees: 5c15 Waiver Fees:
Date of Payment: 31 a b 119 Date of Payment:
Receipt Number: 00 9.--11 t) Receipt Number:
Permit No. OY \ctIolog, Waiver No.
Permit App_:- :..,c
4i• .
' GE
l N G I N E E R I N G
PO BOX 240773
ANCHORAGE,AK 99524
522-7773 677-7766(FAX)
March 19,2019
MOA Development Services Dept, On-Site Water& Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: US Survey 3202 Lot 22—NHN Seward Highway
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot has septic system on the property that protrudes onto the adjacent
property to the southwest. The intention is to upgrade to a permitted septic elsewhere on the lot,
so we are submitting this permit application for the construction of a new septic system. The
attached site plan identifies the location of the home as well the septic location and alternate sight.
No conflicts exist between this proposed system and any other well or septic system,whether on
this lot or adjacent lots.
The ground surface on the lot slopes toward the north steeply near the front of the lot, but the
slopes are much milder towards the center of the lot. It is in that flatter area that the new proposed
septic system is located. There are no slopes greater than 25%within 50 feet downslope of either
the primary or alternate site. Contours are shown on the site plan showing the grade and direction
of flow. Stormwater drainage will not impact this septic system. The new trench will be
constructed parallel to the slope as much as possible.
A percolation rate of 1-5 minutes per inch was obtained from the test-hole used for this design.
However,this rate did not seem indicative of the soils encountered in the test hole so a percolation
rate of 30 minutes per inch was considered for sizing the trench to ensure adequate absorption.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all
wells and surface water, and more than 5' away from the septic tank. The alternate site is located
greater than 6' away from the primary site.
Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic
design. If this design is followed, there will be no adverse impacts to adjacent properties.
sookr tttv
Sincerely, `i+ � `.•'�` •+�
cy �
Michael E.Anderson, PE i t? 49 r,
�..N.MM•
•
+` =MICHAEL E. ANDERSON f C
,�f'ty�. NO. cE-4381 r .�'I
♦./14''�.,.� 3/19/19 •' c`'�r
•14*`p&,SS;;Lam.
//
//
// // // // // //
2CO
2001000
FEET
1"=100'
3-BDRM HOME
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
US SURVEY 3202 LOT 22 - BIRD CREEK PARCEL
SLOPES > 25%
SLOPES > 46%
S
E
AW
A
R
D
H
I
G
HW
A
Y
3/14/19
CENTERLINE STREAM
OVERHEAD POWER
RIGHT-OF-WAY EASEMENT
RECORDED IN DOCUMENT
NO. 2006-036798-0
50' BLM RESERVATION FOR ROADWAY
AND PUBLIC UTILITY PURPOSES
RECORDED IN VOLUME 150, PG 309
100' STREAM
SET-BACK
DECOMMISSION EXISTING
SEPTIC SYSTEM PER
MOA CODE
NOTE:
THE LOCATION OF THE EXISTING SEPTIC
AREA IS ESTIMATED.
1500-GAL ADVANTEX FAP TANK
WITH AX20 POD. PROVIDE
MANUFACTURER'S
RECOMMENDED TIE DOWN
SUPPORTS TO PREVENT
FLOATION.
25' LONG x 5' WIDE x 0.5'
EFFECTIVE DEPTH
ABSORPTION TRENCH
2CO
EXISTING WELL
100' WELL
RADIUS
TH#1
EXTENT OF FILLCOCO
MT
MT
ALTERNATE SITE
15%10%10%
US SURVEY 3202 LOT 22
DESIGN FACTORS:SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: 16 - 30 MIN/IN
APPLICATION RATE: 4 GPD/SF
SHALLOW TRENCH SYSTEM
1500-GAL ADVANTEX/FAP TANK
TYPICAL TRENCH SECTION
(NO SCALE)
4" PERFORATED PVC
(HOLES DOWN)
DRAINFIELD ROCK5'
6"
2'
6"
1'
NOTES:
1.GRADE AREA OVER TRENCH TO DRAIN AWAY
2.PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3.CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 2' ABOVE GRADE
FLOW LINE ELEVATION: 2' 6" ABOVE GRADE
TOP OF TRENCH: 5' ABOVE GRADE
450 GPD / 4 GPD/SF /5' WIDE = 22.5 LF TRENCH REQUIRED (25 LF SPECIFIED)
3/14/19
MOA APPROVED SAND
2'
NOTE:
EXCAVATE PAST THE OVERBURDEN TO
RECEIVING SOILS AND BUILD UP WITH MOA
SAND. MAINTAIN 2' ABOVE THE HIGHEST
ORIGINAL GRADE ELEVATION WITH THE BOTTOM
OF THE TRENCH.
2" INSULATION
3:1
PLACE 4' TOPSOIL AND
REVEGETATE MOUND
NIL SOILS LOG AND PERCOLATION TEST ?�` 49th S�
GE 0 -�-s
lip
NEIN!\�1 N G .� E, ANIpERSON tai
�11 i� No. CE-4381 =
LEGAL DESCRIPTION: US SURVEY 3202 LT 22 TION RIW SEC 10 •
�A, 31.419 „N... '•d
PERFORMED FOR: TERRA B. NELSON ,��.P�hi.55 •4•
DATE: 3/5/19 PROJECT No.:
PARCEL ID#: 09 0-022-06 TECHNICIAN:
J. I`1 I L.L E T T F Professional Engineers Stamp:
DEPTH TEST HOLE l
(feet) _ '
1 -111 OB SLOPE SITE PLAN
2
3
4 I GM W/ INCONSISTENT SEE SITE PLAN
5 --1 POCKETS OF ML& SM i
6 -I ,i
7
8 i
9
WAS GROUND WATER ENCOUNTERED? YE S
10-1 WAS
YES @ WHAT DEPTH? 7'
DEPTH OF WATER AFTER MONITORING: 2.5' O
11BOH DATE OF MONITORING 3/ 2/I c.;
12 DEPTH TO
DATE READING GROSS TIME NET TIME WATER NET DROP
13 (MINUTES) (MINUTES) (INCHES) (INCHES)
14 3/5/19 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 1 2:57/3:07 10 0/216 216
2 8:09/8:19 10 0/2- 216
16 3 8:21 /8:31 10 0/2 s 216
17 4 8:33/8:43 10 0/24- 216
18 5 8:45/8:55 10 0/2 s 216
19 6 8:57/4:07 10 O/2 s 216
20
PERCOLATION RATE: 4.4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 1 FT. and 2 FT.
COMMENTS:
MI'T
;NICTPALITY OF ANCHORAGE
ADV.,kNCED WASTEWATER TREATMENT SYSTEM.
MAINTENANCE AND REPAIR tom, E-NIENT
THIS MMINT EN.11"ANCE AND REPAIR AGREEMENT, herein the"AGRCEMENT " niade and
4-b
entered into as of this Day of of 20 by and between
heretic thei TER and the Nf.unicipalitv of
"OWN
Anchorage, herein the '`MU'NICIP.A'I'....,]"'lY"". ill accordance with Ancli-orage Municipal Code
(AMC) 15,65.365. In con.sIderation of the mutual covenants contained h.ereln, the parties to this
Agreement agree as follows,.
1.Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWT ),
described as Advantex Treatment System
located -at (legal description)
US Survey 3202 L22 T1 ON R1 W Sec 10
-s and Alterations.
2. Maintenance, Re an
(',Owner is required to read, understand and initial each,sectioll)
Throti-ahout the term of this Agreement, -the Owner shall enter into_a service aoreernent
withan AW'WTS service and maintenance provider approved by the Wnicipality or the
m,aj-.iu._fiactti,rer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic efflu.ent in
accordance with the equ. iprnerWs approval for operation ill the Municipality.
W
It shall. be the responsibility of the Owner during the term of this Ac-freernent to pay for all
6
YKI -n
repalr(s),.rnainteriaiice, aqjustment(s), replacefilerit costs, and 'nspect'o costs. This
includes an annual maintenance -fee (typically $400 to $600).
Owner agrees that only maintenance and, repair personnel approved by the N/lunicipality
or the manufacturer's representative will inspect and make any, necessary maintenance,
V
repairs or permitted alterations to -the syste.n.i..
Owner acknowledcTes that regular maintenance of anAWW'TS reduces the potential
failure of the systern, which could include sewage backup &r1d. costly repairs or draInfield
replacement.
(rev, 0 I - 5/18/2018
Page 1. of 3
Caw en�_ antenance and
r acknowledges that the Municipality request records of m,,i
repairs from the manufacturer's representative or maintenance provider.
Owner acknowle dues that the fine for -failincy to maintain and repair an AW'WTS n-iay be
assessed its accordance With. AMC 14.60.0' )0.
ac -L to test and insp
Owner frees to grant the M inicipa.Iil�,,, reasonable access ect the
AW*W'IS. The Municipality will. give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property -w.1.11 not occur without a. new
Certificate of On -Site Systems Approval.
Owner agrees that, the AWWTS installation and maintenance requirements as provided
by the AIA/WT S vendor installer and approved. by the Municipality are the governing
guidelines for the construction, maintenance ai-d repai.r of the Owner's AWWTS.
Owner agrees to maintain remote monitoring of th.e AW*WTS as required by the
AW TS approval,
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title., and shall continue
While the AWWTS is operational or taitil title is transferred.
4. Nonwalkrer. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a, waiver of the provisions, nor in any wav affect
the validity of the.A(Yreemelit. or any part hereof, or the right of the Municipality
thereafter to enforce every provision. hereof.
5, Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any atternP t to amend this a(freement by either an
-
unauthorized- representative or unauthorized. in.ea-ns shall. be void.
6, Jurisd-iction: Choice of Law. Any civil action. arising :from. this Agreeme I i:it shall be
brow ht in. the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall.govern the rights and obli.vations of the
parties under this Agreement.
7. Severabl*!Lty. Any provisions of this Agreernent decreed Rivralid by a court of comp, eteiat
jur isdiction shall not invalidate the remaining provisions of the Agreement.
/
1
(re'Paoe 2 of 3
v, 0 51 ' , 8 2 0 18-) C)
OWNER. � l
Bi9'0
�/ I si nature) Date: l �� �lel. U ( g
Te,firCt d(Dn (print name)
STATE OF ALASKA )
) ss.
THIRD JUDICIAL DISTRICT )
The foregoing instrument was acknowledged before me this day of `I "1 dl ,
rC�� ,
2011 ,by-Te c r-o\ 6. Nets611 •`---
� SEE GA i,.
tifi----, /4/Y.." ''..A>A1's
NO A Y 'UB IC FOR 'KA S : ay..••e,,
My Commission expires: - i -7-12) , :•Nn OG�Qi%
4,o'!i• '• OF P.'`,
MUNICIPALITY:
By: I 11 a(signature) Date: 3 11
R�0tcc , Cg,,,y-a (print name) Title:
•
(rev. 05/18/2018) Page 3 of 3
N40° 40' 00"E 330.00'S40° 40' 00"W 159.22' (C)
N
4
9
°
0
1
'
0
0
"W
3
3
0
.
0
1
'N40° 40' 00"E 161.05' (C)N40° 40' 00"E 330.00'N
4
9
°
2
0
'
0
0
"W
3
3
0
.
0
0
'
N
4
9
°
2
0
'
0
0
"W
3
3
0
.
0
0
'
S
EW
A
R
D
H
I
G
HW
A
Y
C
E
N
T
E
R
L
I
N
E
1
1
4
.
2
'
SHED
1
7
1
.
9
'20.2'5
0
'
B
L
M
R
E
S
E
R
V
A
T
I
O
N
F
O
R
R
O
A
DW
A
Y
A
N
D
P
U
B
L
I
C
U
T
I
L
I
T
Y
P
U
R
P
O
S
E
S
R
E
C
O
R
D
E
D
I
N
V
O
L
U
M
E
1
5
0
,
P
A
G
E
3
0
9
CONNEX
CENTERLINE
STREAM
14%5%90'100'100'110'110'84'
CHICKEN COOP
LOT 14
U.S.S. 3680
LOT 15
LOT 13
LOT 23
LOT 21
LOT 2
LOT 22
U.S.S. 3202
11
8
'
94'
1
0
8
'
92'
88'
86'
84'
82'78'94'
112'88'90'86'
88'
98'
92'
50' BLM RESERVATION FOR
ROADWAY AND PUBLIC
UTILITY PURPOSES
RECORDED IN VOLUME 150,
PAGE 309
24.2'40.2'20.1'16.0'
24.2'4.1'EXISTING
HOUSENOTES:
1.THIS DRAWING SHALL NOT BE MODIFIED FOR USE AS A PLOT PLAN WITHOUT
THE EXPRESSED WRITTEN CONSENT OF LCG LANTECH.
2.SNOW AND ICE MAY CONCEAL MINOR SURFACE FEATURES.
3.THE PLAT FOR LOT 14 DOES NOT FORM A CLOSED FIGURE, THE DIMENSIONS
SHOWN HERE ARE THE EXTENSION OF THE SIDE LOT LINES TO THE CENTERLINE
OF THE PLATTED SEWARD HIGHWAY PER U.S. SURVEY 3680. THE ACTUAL
DETERMINATION OF THE SOUTH WESTERLY PROPERTY LINE (BORDERED BY THE
SEWARD HIGHWAY) IS BEYOND THE SCOPE OF THIS SURVEY.
4.LOT 14, U.S. SURVEY 3680 IS SUBJECT TO BLM PATENT RESERVING
RIGHT-OF-WAY PER BOOK 703, PAGE 775.
5.THERE IS AN AGREEMENT TO PROVIDE SHARED ACCESS RECORDED IN
DOCUMENT NO. 2014-027845-0.
LOT 22, U.S. SURVEY 3202 &
LOT 14, U.S. SURVEY 3680
SEPTIC STANDPIPE
WATER WELL
FENCE
LEGEND:
DRAWN DATE:
DRAWN BY:
SCALE:
CHECKED BY:
11/21/2018
SC
ADS/SC
1" = 60'
PLAT:
WORK ORDER:18152
USS 3202 AND USS 3680
FB/PG: 811/68-69
GRID:SW4760
LEGAL
ORDERED BY:TERRA NELSON
SURVEY CERTIFICATION: LCGLANTECH, INC HAS CONDUCTED A PHYSICAL
SURVEY OF THE PROPERTY AS SHOWN ON THIS DRAWING AND CERTIFIES
THAT THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE
PROPERTY LINES AND NO ENCROACHMENTS EXIST OTHER THAN NOTED.
EXCLUSIONARY NOTE: IT IS THE OWNERS' RESPONSIBILITY TO DETERMINE
THE EXISTENCE OF ANY EASEMENTS, COVENANTS, RESTRICTIONS OR
RIGHT-OF-WAY TAKINGS WHICH DO NOT APPEAR ON THE RECORDED
SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION, FOR ESTABLISHING PROPERTY
LINES, OR FOR PLOT-PLAN PURPOSES.
250 H Street
Anchorage, Alaska 99501
Survey Department
Phone: 562-5291
Mainline
Phone: 243-8985
AECC 668
COMPUTED (C)
HOUSE DETAIL
SCALE: 1" = 20'
EXISTING HOUSE
(SEE DETAIL)
RIGHT-OF-WAY EASEMENT
RECORDED IN DOCUMENT
NO. 2006-036798-0
POWER
POLE
(TYP)
DESCRIPTION:AS-BUILT
Q � Q V} !e Q
J�
0
U
�r
O
1
0
LO
N N>
(y
CD
1
4
N �
LP �■
QT
�^
r
N
L.L.
U
Qy
� �
r
O
Q � Q V} !e Q
J�
0
U
U t.
U >1
N N>
_
L.L.
cu
U U
t
�
N
L
N
cn
+�+
WO
6J
"O
Q
O
OU
7
y
0
cn
U
J
i••.
4.%
G7 R
6
i�
y
tu
3
�
w
�
�
�
ocn
Q.
C7
Q
c
o
CD
`
w
U
i
Q
o
O
�
R
3
m
O0
-a
O
°
-o
s.
.c
ca
o
A
as
cz
R
�•
m
a
�+
y
[�
L
2
�n
L
bIJ
CA
U
L
010
c¢
a.
�
o
s -u
w
y
sz
CA
o..
co
°'
O
L
>,
En n
CA
U
c3
=
61
N
R
_
N
N
c r�
O
L
•�
I�
L
a�
..
a�
3
Q
�
y
�,
•�
�
�,
•U
o
L_
a
.y
.� a�
' --
N .U+
z �7-
o
U
LZ
"'
V)
�_
S
0
0
o
O
0
S
C
OA
U
.�
cri
W
�O
T
o
s
a•
o
v
�.
v.
OU
u
❑.N
O
L
in
OL
0
w
O
s
v
-o
a
o
U
o
Z
a
i.�
0
3
'>
¢
Y=
,_
v
0
a�
-a
O
ca
U
O
a
v
Q
-v
0
a
Q
v,
u
v
o
..
NLn
o
[`1
❑
"G
V
U
0
'O
vi
cl,
C
od
y
O
ami
GTS
c3
o
�
q�j
O
o
N
O
a
v �,
v
p¢¢
F
N
O
V
a
y
¢
a
c
c
3
do
o
w
o
coCZ
v
'o
EEn
Cc
co
3
a
U
v
va�
v
i
U
v
L.
0
E
o
a
w
o
a.
o
o
o
o
ti
U
Cc
o
td
o'
W
U
4-
v
cn
U
I-
v
U
0
�,
v
cn
as
En
o
0
0
v
3
c
v
�
th
3
4
I.-
ao
O
o
-a
cn
3
o
y
`�
¢
to
3
U
p
O
Q
V O
'a
V
0
C
y
E
.�
-0
X
id
❑
C'sQ!
ti
a
v
v�
ay
s
o
W
0
v)
' --
N .U+
z �7-
o
v O
LO
o
=cv�
N O
' --
N .U+
z �7-
o
W
V
a
a
E-'
CLOD
w
w
W
H
w
a
W
z
P -
.a
�
w.
o
J
U
^
C
w
0
v
w
E
a
L
v
Q
G7
V;
3
Q
cn
ab
�oc�
L
O N
a.
O
m z
o
cn
y
I�
0
U
m
0
C*
ID
tiL6
o �
N O
rn �
to
a
Z 10
lit, IBl�tll90'k�lEla4fi
z
O
U
F-
v F-
Z
� QU
0
D
LU
n cn
O
L LL
CL
z°
o
�
a
`
�
_
r
N
LLJ
U
UJ
/
N
rY1
1
H
mor, J
/ C�
0
•�
O0 7
N
%
��C? yid
?
UN
En
LL
/ m Q
oa;
o— m
/ PJ ry
a •�
LC ow
mm�rn
co
A
CL
OA
o m
up
❑
ce
m
m
m y v
a
ct
co Q
LrJnI
>
> >
a
E
n m
E
Om
O
Z 10
lit, IBl�tll90'k�lEla4fi
z
O
U
F-
v F-
Z
� QU
0
D
LU
n cn
O
L LL
CL
z°
cf
�
`
N
1
0
•�
�
%
?
i
N
d d
CL
o m
❑
m
m
m y v
a
LrJnI
>
> >
a
E
n m
E
Om
O
V
a
O D
4 y
u a
LlJ
LLw
w
cf
Job No. i6 -3.o5
M -W Orilling, Inc.
*P.O. Box 110389# Anchorage, AK 99511♦
0907-345-4000 � 907-345-3287 Fax♦
GROUNDWATER WELL LOG
Well Owner: Terra Nelson
Legal Description: US survey 3202 Lt 22 Tso N R3.w Sec zo
Drill Method: Air Rota
Casing Size: 6"
Well Completion: Open end
Screen/Perforation description:
Use of Well; Domestic
CONSTRUCTION
Hole Size: 6" Hole Depth: 3o6'
Cased to: 52.46' Material: A53B Wall: 0.250
X Screen Perforated Method:
Urout Notes: (3 ) Sack(s) of Bentonite
Well Development:
Air Surge
Well Disinfected:
Yes Method:
Yield test at 3
GPM for s
Method: Air Lift
Start Date:
3/21/2os6
Test Pump Date:
n/a
bleach
hour(s) with s00% of drawdown (DD) from static level(SWL).
Static Water Level (SWL): 26'
Completion Date. 4/2/2oi6
Final Pump Install Date: 5/10/2o3.6
WELL LOG
Depth in feet from top
of feet
casi_°
Details of formations penetrated, size of material, color and miscellaneous details.
TO
3
Ca s i n g Stick Up
3
_ TO
Pad fill gravel
�5
To
37
Gravel: cobbs silk, dark grey"
37
To
42
_G ravel:grey, silty! wet
42
TO
-
5o ----------
Gravel: silty, grey,
5o
TO
3o6
Bedrock: water seepage in sporadic fractures
TO
TO
TO
TO
TO
President , MAW Oril[1ng,_Incz__
TO
W4 A Certified Master Groundwater CanfMctat ----- ____
TO
VVATER WA ITY TESTING—
TO
TO
---�+At:-des-_-_k�---M91L------ __
TO
� rsQrtiic 3 ug/L
9/30/13
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: _______________ Date of Issue: ____-____-____
Parcel Identification Number: ____-____-____
Legal Description Block Lot Property Owner Name & Address:
Pump Installation Date: _____-_____-_____
Pump Intake Depth Below Top of Well Casing: __________ feet
Pump Manufacturer’s Name: ___________________________
Pump Model: _____________________________________
Pump Size: ____________hp
Pitless Adapter Burial Depth: _________ feet
Pitless Adapter Manufacturer’s Name: _________________________
Pitless Adapter Installer: ____________________________
Well Disinfected Upon Completion? Yes No
Method of Disinfection: _____________________________
Comments:
Pump Installer Name: __________________________________
Company: ___________________________________________
Mailing Address: ______________________________________
City: ___________________ State: __________Zip: _________
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
X
Ort -Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151193
Tax Code Number: 09002206000
Work Type: Well Initial
Permit Effective Dates: January 15, 2016
to January 14, 2017
Design Engineer:
Subdivision: US SURVEY 3202
Site Legal Address: US SURVEY 3202 LT 22 T1ON R1 W SEC 10 0:4760
Owner/Address: NELSON TERRA B
4401 MARS DR ANCHORAGE AK 995073720
Site Mailing Address:
Lot Size in Sq Ft: 108900
Total Bedrooms: 3
This permit is for the construction of:
N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing
Special Provisions: The septic system shall be approved by the On-site Water and Wastewater
Program prior to installing the well pump.
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907 -
Fax:
ON-SITE SEWERNVELL PERMIT APPLICATION
Parcel I.D. 6 70 OPoZ OC-QQ1)
Property owner(s) 710(04 41e,4Oti- / Day phone
Mailing address P6 sox l3 Iii/'�r✓aid ,4R 995g9
Site address
Legal description (Sub'd., Block & Lot) _3-262 / 'j' .2.2
Legal description (Township, Range & Section)
Lot Size (O 206 Sq. Ft. Number of Bedrooms S
APPLICATION IS FOR:
all that apply)
Absorption Field 9
Septic Tank ❑
Holding Tank 9
Privy 9
Private WeII
Water Storage 9
APPLICATION IS AN:
Initial
Upgrade
Renewal
0
0
TYPE OF DWELLING:
Single Family (SF) El-
(w/wo ADU)
Duplex (D) 0
Multiple Dwellings ❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: $9./5 Waiver Fees:
Date of Payment: (o/Z�//5 Date of Payment:
Receipt Number. *Receipt ' Receipt Number:
Permit No. 4SP1514 Waiver No.
Permit App_9-1-12.doc
January 14, 2015
Planning and Development Services
On -Site Water and Wastewater Program
Municipality of Anchorage
4700 Elmore Road
Anchorage, Alaska 99507
Re: 05P151193 for Terra Nelson
Legal Desc: US Survey 3202 LT 22, T10N R1W, Sec 10
To Whom it May Concern:
An approved COSA will be acquired after the new well has been permitted, constructed, and received
operational approval. Please see attached email from James Crewdson dated December 14`h, 2015.
Terra Nelson
907-202-3101
/
/ \ \
�, \
al (Qi, \
S9?r. \ or 2 N
2''996.0 N e�,rti �G•A/C \
a°98 \ cS q \
�'9�,y��J \92� SGeO N
J /
LOT 23
4 0 629Qti \
,
6
s90 29 N
2 '6
'IC*
F`y29
3?96rmo.
J
8312T
LOT 13�0�9
to.
\b07G
O
11.0\ ,
1 Story Frame House on Piles
Top fdn= 122.7
aY / 6>e F
k%
a24
• 9 °O
S"'000°///�0
Geo J
LOT 14 USSI3680
52,718.6sf
1.21 Acres
g:
Corner not set or found
Point falls on highway
Qa
f1/4
aoe
LEGEND
Found 2 1/2" Aluminum Cap Monument
a Found Rebar with 1 1/2" Aluminum Cap
• Found 5/8" Rebar
(R) Record per Plat No. 92-8, Auriga Subdivision
(R1) Record per U.S. Survey 3202
(R2) Record per U.S. Survey 3680
(M) Measured
EASEMENTS OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON.
$s,
Set lath on
ry
.0
fOr CS.
g)
t;i3 e)
o
li1tWell (Propo ed) LOT 21
V14cad
od
9' x 22' CEA Easement
(Serial No. 2008-036798-0)
o \ /
/
property line \
at top of slope
ACYo along Seward Highway
oris \
sor
o° ser\
69° „
h o4'Sy CY
�
•C OF••: 111
% fir• •49th /\ * 0
BGG /1 •-/
/X c /
iI 4% Fred Walatka: u of
ow
i `"at • 3255 - S ••
e�
$ �opess1oNA� ��•
•
Fb 07-2, pg 6-7 12 1 j S
BE
LOT 15
LOT 14
SCALE: 1"= 100'
Note: Staking prior to construction
REVISED 12-17-2015 (
PROPOSED CONSTRUCTION
I hereby certify that I have surveyed the following described
property: LOT 22, U.S. SURVEY 3202 and
LOT 14, U.S. SURVEY 3680
Anchorage Recording District, Alaska, and that the
improvements situated thereon are within the property lines and
do not overlap or encroach on the property lying adjacent
thereto, that no improvements on property lying adjacent thereto
encroach on the premises in question and that there are no
roadways, transmission lines or other visible easements on
said property except as indicated hereon.
Dated at Anchorage Alaska
This 9th
(907-248-1666)
day of June 2014
FRED WALATKA & ASSOCIATES
Engineers and Surveyors
;r.
--;141111111W[01111111"111111:
-
{$193
:ReoQllldtnlDiet .3ot , r rIo age
r . 6Y5%2(loli 2 29 PM Pe ei ;of
IIIINII1111111111 I�ViNit IIIIE IIIIIIIUIII0l iI
EC i,49.. q Ioa
tilt/ xc
{
r�gUolege AlAsl'i# } ., 94.0f0 14 0,4
45`J% p4 0,':
Int tea Im S et'��,
+Ttttalt
'fit Alma Geta
to naiad to a lard t'olootaaararr *IS Ata of Craw of Ate* 1. tier (ti OWL moi),
is the
raeeaaded 4i aealeadame 11, ado (T4 itst. W). owl tha aqs boatal threfe,
tee *bola
eed la V. 1. An* ate. 9aa, Maw as Oa Lasted
WS* aft NS Crook Maebe,
estatalig1.Ti won
Now Us TT. that Om is.
Om row ottani Us
kata alatriv`y„*''*ys r toVflSOiDnoaktii STATER. ,Wa :ea
thor dal t arrintrt,Wet as_ .11abtri. BOLO aTTOka Wad
TTSCICTIOGTO PBL
=MD A'APitt
tor *taboo a* amnia
1. thud . Mt davit W. OraUSI atm 4,1 V to the 11. IL e1 the
A 4 etsta-ol-ey *um tor tho
Landsaaroa pguanslheranddire**oby th• Act at�u 151 3*bat. 3003.
Mon
MYioaar •ai al alicartaart peogiewee, saws art atm* aroma sad
t MIPS Irai tho salsa as p abs � Ow'ar lilt a ,T. r highway
MQwrlgnaw e Os 0a, amble alosaaattn, his" for a Niateia aLao
ahaaart 7i. 1901. t1 Ns. Tao, 49 tt. i. can Lad
7e Waraee asthtebad at
it Bums at thelaw of Jar rta t w e
g Tat orm. MrydYeWydlatiratedYs ryshpiiiaK
sad GS Sat at the ass to a Maar*
0. r ia¢ hat ho Aaiat � re.Air
griginom
Led
. adisi mumeslab .Laarlr'tuav Starr as
w
•
•
•
Boat 708
PROBE TN[ OnS w
Zac yan
Please return to:
82.
Joseph M. Moran. Esq.
MEEDES, SCHAIBLE. STALEY
DeLISIO, INC.
nEE:0776
943 W. Sixth Avenue
Anchorage. AK 99501
Thank you.
Amwa .nm r", r m, r m or.. .r.
010772._ ..
t►IECWi °�'
M4(»4ORACE REO
DISTRICT -
Iw
1113011'11- -
LOUE81EOtYMOVES -1CTR
r.apRESi F.:Sr ?$a
-}{. 1 -`1142.
SpurtAand Engineering
Environmental Consulting and Design
Municipality of Anchorage
Development Services Department
On Site Water and Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99519
Subject: Septic System Inspection
US SURVEY 3202 LOT 22
Ladies and Gentlemen:
May 19, 2014
The owner of the above referenced property would like to apply for a land use permit to build a
three bedroom single family residence. The property has an MOA approved septic system that
was installed in 1976 to service a restaurant. The onsite file contains a permit application, a soils
log and percolation test results, and an inspection report. The septic system consisted of a 750
gallon septic tank, a 1000 gallon septic tank and 36 feet of deep trench absorption field with 8
feet of effective depth.
The septic system was inspected on May 19, 2014. Tank clean outs and a trench sump were
located. The tanks appear to be full to the outlet levels and the trench sump was 70 inches deep
and dry.
Based upon this information, the existing septic system appears to meet current minimum
standards for a 3 bed room single family residence.
If you have any questions or concerns, please contact me at 279-3916.
Si�acere y, r PSE.Q F ,A, <. , i•41 -i
' i7 vt
..ilTF J
ars`Sp kland, F.E.
Civil Engineer
•
SPURKLAND. E ,01
160 ' C7i
203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspuridand r(Qgcienet
Page 1 of 3
Crewdson, James A.
From: Crewdson, James A.
Sent: Friday, December 04, 2015 2:08 PM
To: Walsh, Sharen A.
Cc: Frost, Jack L.; Calhoun, Sonnet L.; Schutte, Christopher M; Rivera, Felix; Oswald, Tammy R.;
Wockenfuss, Deborah M.
Subject: RE: Letter from a Concerned Municipality Resident
Sharen,
The following history regarding well and septic on the subject property is what I'm finding in On -site's records.
History:
• 1976: On-site issued a permit to construct a septic system serving a "bar and cafe" at the subject property
on 8/10/76. The system received final operational approval on 8/30/76.
Note: although On -site's scope of regulation probably never officially included commercial properties,
occasionally we will find where On-site was in fact involved with one. This is more common prior to the
1980's.
• 2014: Lars Spurkland/Spurkland Engineering (deceased) appears to have been retained by the owner to
inspect the septic system. In his report dated 5/19/14 he states the "existing septic system appears to
meet current minimum standards for a 3 bed room single family residence". While his report is
encouraging that the system may be approvable; it doesn't indicate that an adequacy test was performed
on the septic system drainfield, which is one of the requirements for a Certificate of On-site Systems
Approval (COSA). Per AMC 15.55 and 15.65, a COSA is required prior to the transfer of ownership for
residential properties served by a well and/or septic system.
Note: a COSA doesn't appear to have been submitted to On-site.
• 2015: Terra Nelson applied for an on-site private residential well permit (OSP151193) on 6/23/15. Review
comments were issued and emailed to her at tnelson0880(domail.com on 7/8/15. Per On -site's records,
she doesn't appear to have responded to the review comments.
Commentary:
• On-site has discussed the issues with the owner and/or her fiance at the front counter on multiple
occasions. I don't believe any of the discussions were in a documented meeting.
• Deb Wockenfuss handled some of these discussions. I don't know the details of those discussions.
Thanks
Jay
James "Jay" Crewdson, P.E.
Civil and Environmental Engineer
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
Location: 4700 Elmore Road
Mail: P.O. Box 196650, Anchorage, AK 99519
v. 907.343.7908 f. 907.249.7601
12/4/2015
GREA1Lk ANCHORAGE AREA BOROtiH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
Gem, $ ` r.
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME %/!/'C ForrFA/ MAILING ADDRESS Si& Bax /Ityr 4. 4,rcfi PHONELa /�/ /
Sfryt
LOCATION EGAL DESCRIPTION //��[1 /WOC /0 !�(7j /� �"/�r
SEPTIC TANK:
DISTANCE
FROM WELL/ T MANUFACTURER r /ZQen- MATERIAI
INSIDE LENGTH
tt S 360
INSIDE WIDTH LIQUID DEPTH
7sof
NUMBER OF /U��
COMPARTMENTS
LIQUID CAPACITY GALLONS.
TILE DRAIN FIELD: qq77
DISTANCE FROM WELLp2&D
FOUNDATION /() NEAREST LOT LINE
/0/
NUMBER OF LINES (`� DISTANCE BETWEEN LINES /j'/� TRENCH WIDTH
ABSORPTION AREA ' SQ FT LENGTH OF EACH LINE 3`-'�
/ DEPTH OF FILTER,,
DEPTH: TOP OF TILE TO FINISH GRADE / MATERIAL BENEATH TILE _L4ABOVE TILE � IN
WELL: No 2,2,11E D wic//
f 057i0i4-
TYPE CONSTRUCTION DEPTH DISTANCE FROM:
TOTAL LENGTH,
OF LINES
TOTAL EFFECTIVE
/lmv6a Due- it -V//
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION LOT LINE SEWER LINE TANK SYSTEM
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED
REMARKS
DISTANCES'
INSTALLED BY• C//Ae/P S1,-771
SEWER LINE DEPTH
PIPE MATERIAL'
LOT SLOPE I/C�
REMARKS
Form EQ -032
fO
��SDIAGRAM OF SYSTEM
N
DATE3O177 APPROVED
G.A.A.B.
ofc
/ . 3- r /moo (-�o. o
GREATER ANCHORAGE AREA BOROUGH r
DEPARTMENT OF ENVIRONMENTAL. QUALITY
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
SEWAGE DISPOSAL SYSTEM — APPLICATION AND PERMIT
NAME OF APPLICANT
d A c, c/( Fr,e, e
INSTALLATION LOCATION
LEGAL DESCRIPTION
INSTALLATION OF: SEPTIC TANK
''&/ y/
MAILING AD DR E SS547/ 99)C /f/i"
PHONE7Vt 25-9/
Aro & t
TYPE AND SIZE OF FACILITY TO BE SERVED
SEEPAGE PIT - DRAIN FIELD
I
/ Q / c/cJ
TO BE INSTALLED BY 1 -� c'k ��o` /Y->�y,C4
�ncxA U
FINANCED THROUGH
SOIL TEST RESULTS
iro
, OTHER7/I C,C
fru-
COMPLETION DATE ANTICIPATED i o /" CJ -t; r..f A/
NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
FINAL. INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL. BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE / 07-0
TYPE
SEEPAGE AREA SIZE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK
TO NEAREST LOT LINE.
SEEPAGE PIT DRAIN FIELD
WELL TO SEPTIC TANK SEEPAGE PIT
DRAIN FIELD ALSO CONSIDER AREA WELLS
WATER MAIN TO SEPTIC TANK SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK. . SEEPAGE PIT DRAIN FIELD
TO RIVER. LAKE. STREAM.
o- DIAGRAM OF SYSTEM
TYPE / eevcrt
ri✓ y—'c'
7
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
OR
LICENSED DESIGNER
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER A
DESCRIBED SYSTEM 15 IN ACCORDANCE WITH SAID CODE.
DATE (�
—7 ,C
APPLICANT'S SIGNAT
ORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
Sanitary Sewer Test Hole
Benny Garcia
Bennies Paradise Seward Hwy
DWN: MAIZ
CKD:
DATE:
SCALE: 1"=3'
V
RSM CONSULTANTS, INC.
T.H. 1 7/31/76
ORGANIC MATERIAL 1'
SILT W/SOME GRAVEL
& TR SAND
6.5'
SILTY SAND W/TR GRAVEL
& OCCASIONAL COBBLES @13'
13'
SILTY SAND
W/SOME GRA\pC
18:5' T:D.
NO WATER TABLE W.D.
This log represents subsurface';
soil conditions within Bennies •
Paradise. Seward Highway
F. B.
GRID
PROJ.NO. 656277
DWG. NO.
r 0' �
RaM CONSULTANTS, INC.
248 EAST 51 ST. AVE. • OOX 8007 • ANCHORAGE, AK. 02002 • P.N. 807278. 0423 • TLX. 0E10.2 3130
August 5, 1976 R & M No. 656277
Benny Garcia
Bennies Paradise
Seward Highway
Anchorage, Alaska 99507
RE: Test Hole and Soil Log Report for Sanitary System
Bennies Paradise Seward Highway
Dear Mr. Garcia:
We are submitting herewith the test boring results and our comments
regarding soil conditions encountered at the subject site. This investigation
was performed in accordance with your request of July 27, 1976 and those
procedures outlined in a letter dated July 15, 1975, by Mr. Rolf Strickland
of the Greater Anchorage Area Borough Department of Environmental Quality.
A single test hole was put down within the subject site area for the
purpose of defining general subsurface soil conditions for the proposed
sanitary system. Excavation was accomplished with an auger type drilling
rig and the test hole was extended to a total depth of 18.5 feet below
ground surface. The final log prepared for the test hole has been
included in Drawing A-01.
Ground water was not encountered in the test hole while drilling.
We appreciate being given this opportunity to be of service to you.
Should you have any questions with regard to the above, please do not
hesitate to contact us.
Very truly yours,
R & M CONSULTANTS, IINNC. )
(7,41:AALLA C-1
James W. Rooney
Vice President ,ll5
i.'
JWR/ddp
xc: GAAB
ANCHORAGE FAIRBANKS JUNEAU
TIME
10:00
10:01
10:02
10:03
10:04
10:05
10:06
10:07
10:08
10:09
10:10
10:15
10:20
10:25
10:30
10:40
10:50
11:00
PERCOLATION TEST
BENNY GARCIA
R & M NO. 656277
ELAPSED
TIME
0
1
2
7
8
9
10
15
20
25
30
40
50
60
60 Minutes
DROP IN
INCHES
. 5
.5
0
.25
.25
0
.75
. 25
. 25
.75
. 5
. 5
5.50" Total Drop
7 / /14 /NA/6JY