Loading...
HomeMy WebLinkAboutUS SURVEY 3202 LT 22 T10N R1W SEC 10U55 3202 Lot 22 #090 - 022 - 06 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191062 I PID Number: 090-022-06 Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑■ Upgrade Name: Terra Nelson ABSORPTION FIELD E] Deep Trench 0 Shallow Trench E] Bed ❑ Mound Address PO Box 483 Girdwood AK 99587 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 202-3101 3 4.0 GPD/SF +2 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +2.6 Ft. Gravel depth beneath pipe 0.6 Ft. Subdivision Block Lot US Survey 3202 22 Fill added above original grade 5.3 Ft. Gravel length 25 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 125 Ft 1 Ft. Well >100' >100' N/A N/A >25 TANK ❑ Septic ❑ S.T.E.P. ❑ Holding Other Manufacturer Orenco / Advantex (FAP) Capacity 11500 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A Fiberglass 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Trench is insulated. Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Wilco Contractors Drainfield D3034. CO/MT Inspector J. Williams BENCH MARK (Assumed elevation) 100 ft Inspection ection 1s' 4/1/19 d 4/2/19 Location and description 2 3'd 4`h Bottom of siding. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional OF Approval: Date T . see hP Vt_V,2 T_r,-c�-7 o/ 9th ••s.....� U/ q / ✓ ^C( IrC2X�l /'YLU (,(/j d ... :. ............ ' ;- G. L Jap �LGGrC �., l�(J/'/��2�: ®.uu....um..I..nu..........unu.....un ��n'; MICHAEL E. ANDERSON f ii a % No. CE-4381 �� w 4 C� Approved �i�R Date 5 /� X0:2 7 � C" •°°•.°° 7/9/19 .°••' J�5 �e t01VPROFESS���®+�� iaNcl�uvi 1 r UPUI i_V- i- 1 c.uuc US SURVEY 3202 LOT 22 - BIRD CREEK PARCEL PERMIT # OSP191062 / / 50' BLM RESERVATION FOR ROADWAY AND PUBLIC UTILITY PURPOSES RECORDED IN VOLUME 150, PG 309 -,LPT 2 \ \ T CENTEkLINE STREAM LO23 \ ! \ a \ ALTERNATE SITE v \ OVERHEAD POWER LOT 22 /t ��t \ f r t 2 °' -1-- / 25' LQIgG x 5' WIDE x 0:5' / Ey�FFECTIV�/E°DEPTH \ .FABSORPn ION TRENCH,_ 100rSTREA .SET -BACK' r r — _, ........ .., .� / r 001 ! ` r r. Myr nnhz X500 GA1 AdUAYVTEX t 'r'_ 'r''1 A-RTA`NK'v�i/Ak,X POD ter` •'r N. — EXTEL`1T'C'7� FTLLi ter.,. it lgyl _ _ _ _ \ vtv _r _ ` ✓iii /�r'' t /2�ELL aoM H RADIUS LOT 21 'EXISTING WELL L v. RIGHT-OF-WAY EASEMENT \\ \\ � ` `\�\moo\ \` RECORDED IN DOCUMENT v v { vvvvvv " ANO. 2006-036798-0 \ ` LOT 1 ENGINEERING 49th MICHAEL E. ANDERSON No. CE -4381 ,e• �q, 719/19 .•'° ���e • i' \ t e PLAN AS -BUILT 0 100 200 1 EN FEET 1"=100' 20S� 21.9 14.6 MH1 35.6 19.9 LEGEND CO — CLEANOUT 2CO — DOUBLE CLEANOUT FCO — FOUNDATION CLEANOUT FS — FLOW SPLITTER VALVE MH — MANHOLE MT — MONITORING TUBE SV — SEPTIC VENT TH — TEST HOLE 67.3 66.7 US SURVEY 3202 LOT 22 PERMIT # OSP191062 �— 70.0 FINISH GRADE MOA APPROVED FILTER SAND 2" INSULATION 67.3 --66.7 62.9 (West) 63.7 (East) 64.7 ORIGINAL GRADE 25' GROUNDWATER @ 62.2 3/12/19 53.7 PSE, OF e fiAw d•, 49th ' r MICHAEL E. ANDERSON PROFILE AS -BUILT ����=.. No. CE -4381 r 4!25!19• ••°� ¢NGINEENINC (NO SCALE) ,f VESSICt�®® N40° 40' 00"E 330.00'S40° 40' 00"W 159.22' (C) N 4 9 ° 0 1 ' 0 0 "W 3 3 0 . 0 1 'N40° 40' 00"E 161.05' (C)N40° 40' 00"E 330.00'N 4 9 ° 2 0 ' 0 0 "W 3 3 0 . 0 0 ' N 4 9 ° 2 0 ' 0 0 "W 3 3 0 . 0 0 ' S EW A R D H I G HW A Y C E N T E R L I N E 1 1 4 . 2 ' SHED 1 7 1 . 9 '20.2'5 0 ' B L M R E S E R V A T I O N F O R R O A DW A Y A N D P U B L I C U T I L I T Y P U R P O S E S R E C O R D E D I N V O L U M E 1 5 0 , P A G E 3 0 9 CONNEX CENTERLINE STREAM 14%5%CHICKEN COOP LOT 14 U.S.S. 3680 LOT 15 LOT 13 LOT 23 LOT 21 LOT 2 LOT 22 U.S.S. 3202 50' BLM RESERVATION FOR ROADWAY AND PUBLIC UTILITY PURPOSES RECORDED IN VOLUME 150, PAGE 309 AT MH MH 24.2'40.2'20.1'16.0' 24.2'4.1'NOTES: 1.THIS DRAWING SHALL NOT BE MODIFIED FOR USE AS A PLOT PLAN WITHOUT THE EXPRESSED WRITTEN CONSENT OF LCG LANTECH. 2.SNOW AND ICE MAY CONCEAL MINOR SURFACE FEATURES. 3.THE PLAT FOR LOT 14 DOES NOT FORM A CLOSED FIGURE, THE DIMENSIONS SHOWN HERE ARE THE EXTENSION OF THE SIDE LOT LINES TO THE CENTERLINE OF THE PLATTED SEWARD HIGHWAY PER U.S. SURVEY 3680. THE ACTUAL DETERMINATION OF THE SOUTH WESTERLY PROPERTY LINE (BORDERED BY THE SEWARD HIGHWAY) IS BEYOND THE SCOPE OF THIS SURVEY. 4.LOT 14, U.S. SURVEY 3680 IS SUBJECT TO BLM PATENT RESERVING RIGHT-OF-WAY PER BOOK 703, PAGE 775. 5.THERE IS AN AGREEMENT TO PROVIDE SHARED ACCESS RECORDED IN DOCUMENT NO. 2014-027845-0. LOT 22, U.S. SURVEY 3202 & LOT 14, U.S. SURVEY 3680 SEPTIC STANDPIPE WATER WELL FENCE LEGEND: DRAWN DATE: DRAWN BY: SCALE: CHECKED BY: 5/7/2019 SC ADS/SC 1" = 60' PLAT: WORK ORDER:18152 USS 3202 AND USS 3680 FB/PG: 811/68-69 GRID:SW4760 LEGAL ORDERED BY:TERRA NELSON EXCLUSIONARY NOTE: IT IS THE OWNERS' RESPONSIBILITY TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS, RESTRICTIONS OR RIGHT-OF-WAY TAKINGS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION, FOR ESTABLISHING PROPERTY LINES, OR FOR PLOT-PLAN PURPOSES. 250 H Street Anchorage, Alaska 99501 Survey Department Phone: 562-5291 Mainline Phone: 243-8985 AECC 668 COMPUTED (C) HOUSE DETAIL SCALE: 1" = 20' EXISTING HOUSE (SEE DETAIL) RIGHT-OF-WAY EASEMENT RECORDED IN DOCUMENT NO. 2006-036798-0 UTILITY POLE (TYP) DESCRIPTION: EXISTING HOUSE AT - ADVANTEX TANK MH - MANHOLE SURVEY CERTIFICATION: LCG LANTECH, INC HAS CONDUCTED A PHYSICAL SURVEY OF THE PROPERTY AS SHOWN ON THIS DRAWING AND CERTIFIES THAT THE IMPROVEMENTS SITUATED THEREON EXIST IN THE LOCATIONS AS SHOWN AT THE TIME OF SURVEY. AS-BUILT H`c%PALITT MUNICIPALITY OF ANCHORAGE ...\OF ill l r On-Site Water&Wastewater Program ��� `M S PO Box 196650 4700 Elmore Road 044/ Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 / http://www.muni.org/onsite Department �NCMONAVE On-Site Wastewater Disposal System Permit Permit Number: OSP191062 Effective Date: 3/27/2019 Work Type: Septic Upgrade Expiration Date: 3/26/2020 Tax Code Number: 09002206000 Site Legal Address: US SURVEY 3202 LT 22 T1 ON R1W SEC 10 G:4760 Site Mailing Address: Owner: NELSON TERRA B Lot Size in Sq Ft: 108900 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: El Disposal Field El Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. In order to close out this permit, the well permit (OSP151193) shall be closed out by providing the following: a) Well log b) Pump install log c)Water sample results for total coliform, nitrates and arsenic. 2. The drainfield shall be entered at the midpoint, as shown on the site plan, to comply with AMC 15.65.355H.2, allowing two foot separation to seasonal high groundwater. n 1 Received By: ( � f � �/' � i Date: 1 Issued By: R Date: 31 Ir MUNICIPALITY OF ANCHORAGE • . it Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 090-022-06 Property owner(s) Terra Nelson Day phone (907) 202-3101 Mailing address PO Box 483 Girdwood AK 99587 Site address NHN Seward HWY. Bird Creek, AK Legal description (Sub'd., Block & Lot) US Survey 3202 Lot 22 Legal description (Township, Range & Section) Lot Size 108,900 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ❑X Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with 2 nnlino hlo T Ai inininol (`nr•Icc-14/L,f2,Q, V v (Signature of property owner or authorized agent) Permit/Rush Fees: 5c15 Waiver Fees: Date of Payment: 31 a b 119 Date of Payment: Receipt Number: 00 9.--11 t) Receipt Number: Permit No. OY \ctIolog, Waiver No. Permit App_:- :..,c 4i• . ' GE l N G I N E E R I N G PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) March 19,2019 MOA Development Services Dept, On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: US Survey 3202 Lot 22—NHN Seward Highway Septic system design Dear On-Site Services Engineer: The owner of the above lot has septic system on the property that protrudes onto the adjacent property to the southwest. The intention is to upgrade to a permitted septic elsewhere on the lot, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home as well the septic location and alternate sight. No conflicts exist between this proposed system and any other well or septic system,whether on this lot or adjacent lots. The ground surface on the lot slopes toward the north steeply near the front of the lot, but the slopes are much milder towards the center of the lot. It is in that flatter area that the new proposed septic system is located. There are no slopes greater than 25%within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. A percolation rate of 1-5 minutes per inch was obtained from the test-hole used for this design. However,this rate did not seem indicative of the soils encountered in the test hole so a percolation rate of 30 minutes per inch was considered for sizing the trench to ensure adequate absorption. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located greater than 6' away from the primary site. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. sookr tttv Sincerely, `i+ � `.•'�` •+� cy � Michael E.Anderson, PE i t? 49 r, �..N.MM• • +` =MICHAEL E. ANDERSON f C ,�f'ty�. NO. cE-4381 r .�'I ♦./14''�.,.� 3/19/19 •' c`'�r •14*`p&,SS;;Lam. // // // // // // // // 2CO 2001000 FEET 1"=100' 3-BDRM HOME NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND US SURVEY 3202 LOT 22 - BIRD CREEK PARCEL SLOPES > 25% SLOPES > 46% S E AW A R D H I G HW A Y 3/14/19 CENTERLINE STREAM OVERHEAD POWER RIGHT-OF-WAY EASEMENT RECORDED IN DOCUMENT NO. 2006-036798-0 50' BLM RESERVATION FOR ROADWAY AND PUBLIC UTILITY PURPOSES RECORDED IN VOLUME 150, PG 309 100' STREAM SET-BACK DECOMMISSION EXISTING SEPTIC SYSTEM PER MOA CODE NOTE: THE LOCATION OF THE EXISTING SEPTIC AREA IS ESTIMATED. 1500-GAL ADVANTEX FAP TANK WITH AX20 POD. PROVIDE MANUFACTURER'S RECOMMENDED TIE DOWN SUPPORTS TO PREVENT FLOATION. 25' LONG x 5' WIDE x 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH 2CO EXISTING WELL 100' WELL RADIUS TH#1 EXTENT OF FILLCOCO MT MT ALTERNATE SITE 15%10%10% US SURVEY 3202 LOT 22 DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 16 - 30 MIN/IN APPLICATION RATE: 4 GPD/SF SHALLOW TRENCH SYSTEM 1500-GAL ADVANTEX/FAP TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK5' 6" 2' 6" 1' NOTES: 1.GRADE AREA OVER TRENCH TO DRAIN AWAY 2.PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3.CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 2' ABOVE GRADE FLOW LINE ELEVATION: 2' 6" ABOVE GRADE TOP OF TRENCH: 5' ABOVE GRADE 450 GPD / 4 GPD/SF /5' WIDE = 22.5 LF TRENCH REQUIRED (25 LF SPECIFIED) 3/14/19 MOA APPROVED SAND 2' NOTE: EXCAVATE PAST THE OVERBURDEN TO RECEIVING SOILS AND BUILD UP WITH MOA SAND. MAINTAIN 2' ABOVE THE HIGHEST ORIGINAL GRADE ELEVATION WITH THE BOTTOM OF THE TRENCH. 2" INSULATION 3:1 PLACE 4' TOPSOIL AND REVEGETATE MOUND NIL SOILS LOG AND PERCOLATION TEST ?�` 49th S� GE 0 -�-s lip NEIN!\�1 N G .� E, ANIpERSON tai �11 i� No. CE-4381 = LEGAL DESCRIPTION: US SURVEY 3202 LT 22 TION RIW SEC 10 • �A, 31.419 „N... '•d PERFORMED FOR: TERRA B. NELSON ,��.P�hi.55 •4• DATE: 3/5/19 PROJECT No.: PARCEL ID#: 09 0-022-06 TECHNICIAN: J. I`1 I L.L E T T F Professional Engineers Stamp: DEPTH TEST HOLE l (feet) _ ' 1 -111 OB SLOPE SITE PLAN 2 3 4 I GM W/ INCONSISTENT SEE SITE PLAN 5 --1 POCKETS OF ML& SM i 6 -I ,i 7 8 i 9 WAS GROUND WATER ENCOUNTERED? YE S 10-1 WAS YES @ WHAT DEPTH? 7' DEPTH OF WATER AFTER MONITORING: 2.5' O 11BOH DATE OF MONITORING 3/ 2/I c.; 12 DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROP 13 (MINUTES) (MINUTES) (INCHES) (INCHES) 14 3/5/19 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 2:57/3:07 10 0/216 216 2 8:09/8:19 10 0/2- 216 16 3 8:21 /8:31 10 0/2 s 216 17 4 8:33/8:43 10 0/24- 216 18 5 8:45/8:55 10 0/2 s 216 19 6 8:57/4:07 10 O/2 s 216 20 PERCOLATION RATE: 4.4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 1 FT. and 2 FT. COMMENTS: MI'T ;NICTPALITY OF ANCHORAGE ADV.,kNCED WASTEWATER TREATMENT SYSTEM. MAINTENANCE AND REPAIR tom, E-NIENT THIS MMINT EN.11"ANCE AND REPAIR AGREEMENT, herein the"AGRCEMENT " niade and 4-b entered into as of this Day of of 20 by and between heretic thei TER and the Nf.unicipalitv of "OWN Anchorage, herein the '`MU'NICIP.A'I'....,]"'lY"". ill accordance with Ancli-orage Municipal Code (AMC) 15,65.365. In con.sIderation of the mutual covenants contained h.ereln, the parties to this Agreement agree as follows,. 1.Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWT ), described as Advantex Treatment System located -at (legal description) US Survey 3202 L22 T1 ON R1 W Sec 10 -s and Alterations. 2. Maintenance, Re an (',Owner is required to read, understand and initial each,sectioll) Throti-ahout the term of this Agreement, -the Owner shall enter into_a service aoreernent withan AW'WTS service and maintenance provider approved by the Wnicipality or the m,aj-.i­u._fiactti,rer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic efflu.ent in accordance with the equ. iprnerWs approval for operation ill the Municipality. W It shall. be the responsibility of the Owner during the term of this Ac-freernent to pay for all 6 YKI -n repalr(s),.rnainteriaiice, aqjustment(s), replacefilerit costs, and 'nspect'o costs. This includes an annual maintenance -fee (typically $400 to $600). Owner agrees that only maintenance and, repair personnel approved by the N/lunicipality or the manufacturer's representative will inspect and make any, necessary maintenance, V repairs or permitted alterations to -the syste.n.i.. Owner acknowledcTes that regular maintenance of anAWW'TS reduces the potential failure of the systern, which could include sewage backup &r1d. costly repairs or draInfield replacement. (rev, 0 I - 5/18/2018 Page 1. of 3 Caw en�_ antenance and r acknowledges that the Municipality request records of m,,i repairs from the manufacturer's representative or maintenance provider. Owner acknowle dues that the fine for -failincy to maintain and repair an AW'WTS n-iay be assessed its accordance With. AMC 14.60.0' )0. ac -L to test and insp Owner frees to grant the M inicipa.Iil�,,, reasonable access ect the AW*W'IS. The Municipality will. give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property -w.1.11 not occur without a. new Certificate of On -Site Systems Approval. Owner agrees that, the AWWTS installation and maintenance requirements as provided by the AIA/WT S vendor installer and approved. by the Municipality are the governing guidelines for the construction, maintenance ai-d repai.r of the Owner's AWWTS. Owner agrees to maintain remote monitoring of th.e AW*WTS as required by the AW TS approval, 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title., and shall continue While the AWWTS is operational or taitil title is transferred. 4. Nonwalkrer. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a, waiver of the provisions, nor in any wav affect the validity of the.A(Yreemelit. or any part hereof, or the right of the Municipality thereafter to enforce every provision. hereof. 5, Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any atternP t to amend this a(freement by either an - unauthorized- representative or unauthorized. in.ea-ns shall. be void. 6, Jurisd-iction: Choice of Law. Any civil action. arising :from. this Agreeme I i:it shall be brow ht in. the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall.govern the rights and obli.vations of the parties under this Agreement. 7. Severabl*!Lty. Any provisions of this Agreernent decreed Rivralid by a court of comp, eteiat jur isdiction shall not invalidate the remaining provisions of the Agreement. / 1 (re'Paoe 2 of 3 v, 0 51 ' , 8 2 0 18-) C) OWNER. � l Bi9'0 �/ I si nature) Date: l �� �lel. U ( g Te,firCt d(Dn (print name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this day of `I "1 dl , rC�� , 2011 ,by-Te c r-o\ 6. Nets611 •`--- � SEE GA i,. tifi----, /4/Y.." ''..A>A1's NO A Y 'UB IC FOR 'KA S : ay..••e,, My Commission expires: - i -7-12) , :•Nn OG�Qi% 4,o'!i• '• OF P.'`, MUNICIPALITY: By: I 11 a(signature) Date: 3 11 R�0tcc , Cg,,,y-a (print name) Title: • (rev. 05/18/2018) Page 3 of 3 N40° 40' 00"E 330.00'S40° 40' 00"W 159.22' (C) N 4 9 ° 0 1 ' 0 0 "W 3 3 0 . 0 1 'N40° 40' 00"E 161.05' (C)N40° 40' 00"E 330.00'N 4 9 ° 2 0 ' 0 0 "W 3 3 0 . 0 0 ' N 4 9 ° 2 0 ' 0 0 "W 3 3 0 . 0 0 ' S EW A R D H I G HW A Y C E N T E R L I N E 1 1 4 . 2 ' SHED 1 7 1 . 9 '20.2'5 0 ' B L M R E S E R V A T I O N F O R R O A DW A Y A N D P U B L I C U T I L I T Y P U R P O S E S R E C O R D E D I N V O L U M E 1 5 0 , P A G E 3 0 9 CONNEX CENTERLINE STREAM 14%5%90'100'100'110'110'84' CHICKEN COOP LOT 14 U.S.S. 3680 LOT 15 LOT 13 LOT 23 LOT 21 LOT 2 LOT 22 U.S.S. 3202 11 8 ' 94' 1 0 8 ' 92' 88' 86' 84' 82'78'94' 112'88'90'86' 88' 98' 92' 50' BLM RESERVATION FOR ROADWAY AND PUBLIC UTILITY PURPOSES RECORDED IN VOLUME 150, PAGE 309 24.2'40.2'20.1'16.0' 24.2'4.1'EXISTING HOUSENOTES: 1.THIS DRAWING SHALL NOT BE MODIFIED FOR USE AS A PLOT PLAN WITHOUT THE EXPRESSED WRITTEN CONSENT OF LCG LANTECH. 2.SNOW AND ICE MAY CONCEAL MINOR SURFACE FEATURES. 3.THE PLAT FOR LOT 14 DOES NOT FORM A CLOSED FIGURE, THE DIMENSIONS SHOWN HERE ARE THE EXTENSION OF THE SIDE LOT LINES TO THE CENTERLINE OF THE PLATTED SEWARD HIGHWAY PER U.S. SURVEY 3680. THE ACTUAL DETERMINATION OF THE SOUTH WESTERLY PROPERTY LINE (BORDERED BY THE SEWARD HIGHWAY) IS BEYOND THE SCOPE OF THIS SURVEY. 4.LOT 14, U.S. SURVEY 3680 IS SUBJECT TO BLM PATENT RESERVING RIGHT-OF-WAY PER BOOK 703, PAGE 775. 5.THERE IS AN AGREEMENT TO PROVIDE SHARED ACCESS RECORDED IN DOCUMENT NO. 2014-027845-0. LOT 22, U.S. SURVEY 3202 & LOT 14, U.S. SURVEY 3680 SEPTIC STANDPIPE WATER WELL FENCE LEGEND: DRAWN DATE: DRAWN BY: SCALE: CHECKED BY: 11/21/2018 SC ADS/SC 1" = 60' PLAT: WORK ORDER:18152 USS 3202 AND USS 3680 FB/PG: 811/68-69 GRID:SW4760 LEGAL ORDERED BY:TERRA NELSON SURVEY CERTIFICATION: LCGLANTECH, INC HAS CONDUCTED A PHYSICAL SURVEY OF THE PROPERTY AS SHOWN ON THIS DRAWING AND CERTIFIES THAT THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO ENCROACHMENTS EXIST OTHER THAN NOTED. EXCLUSIONARY NOTE: IT IS THE OWNERS' RESPONSIBILITY TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS, RESTRICTIONS OR RIGHT-OF-WAY TAKINGS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION, FOR ESTABLISHING PROPERTY LINES, OR FOR PLOT-PLAN PURPOSES. 250 H Street Anchorage, Alaska 99501 Survey Department Phone: 562-5291 Mainline Phone: 243-8985 AECC 668 COMPUTED (C) HOUSE DETAIL SCALE: 1" = 20' EXISTING HOUSE (SEE DETAIL) RIGHT-OF-WAY EASEMENT RECORDED IN DOCUMENT NO. 2006-036798-0 POWER POLE (TYP) DESCRIPTION:AS-BUILT Q � Q V} !e Q J� 0 U �r O 1 0 LO N N> (y CD 1 4 N � LP �■ QT �^ r N L.L. U Qy � � r O Q � Q V} !e Q J� 0 U U t. U >1 N N> _ L.L. cu U U t � N L N cn +�+ WO 6J "O Q O OU 7 y 0 cn U J i••. 4.% G7 R 6 i� y tu 3 � w � � � ocn Q. C7 Q c o CD ` w U i Q o O � R 3 m O0 -a O ° -o s. .c ca o A as cz R �• m a �+ y [� L 2 �n L bIJ CA U L 010 c¢ a. � o s -u w y sz CA o.. co °' O L >, En n CA U c3 = 61 N R _ N N c r� O L •� I� L a� .. a� 3 Q � y �, •� � �, •U o L_ a .y .� a� ' -- N .U+ z �7- o U LZ "' V) �_ S 0 0 o O 0 S C OA U .� cri W �O T o s a• o v �. v. OU u ❑.N O L in OL 0 w O s v -o a o U o Z a i.� 0 3 '> ¢ Y= ,_ v 0 a� -a O ca U O a v Q -v 0 a Q v, u v o .. NLn o [`1 ❑ "G V U 0 'O vi cl, C od y O ami GTS c3 o � q�j O o N O a v �, v p¢¢ F N O V a y ¢ a c c 3 do o w o coCZ v 'o EEn Cc co 3 a U v va� v i U v L. 0 E o a w o a. o o o o ti U Cc o td o' W U 4- v cn U I- v U 0 �, v cn as En o 0 0 v 3 c v � th 3 4 I.- ao O o -a cn 3 o y `� ¢ to 3 U p O Q V O 'a V 0 C y E .� -0 X id ❑ C'sQ! ti a v v� ay s o W 0 v) ' -- N .U+ z �7- o v O LO o =cv� N O ' -- N .U+ z �7- o W V a a E-' CLOD w w W H w a W z P - .a � w. o J U ^ C w 0 v w E a L v Q G7 V; 3 Q cn ab �oc� L O N a. O m z o cn y I� 0 U m 0 C* ID tiL6 o � N O rn � to a Z 10 lit, IBl�tll90'k�lEla4fi z O U F- v F- Z � QU 0 D LU n cn O L LL CL z° o � a ` � _ r N LLJ U UJ / N rY1 1 H mor, J / C� 0 •� O0 7 N % ��C? yid ? UN En LL / m Q oa; o— m / PJ ry a •� LC ow mm�rn co A CL OA o m up ❑ ce m m m y v a ct co Q LrJnI > > > a E n m E Om O Z 10 lit, IBl�tll90'k�lEla4fi z O U F- v F- Z � QU 0 D LU n cn O L LL CL z° cf � ` N 1 0 •� � % ? i N d d CL o m ❑ m m m y v a LrJnI > > > a E n m E Om O V a O D 4 y u a LlJ LLw w cf Job No. i6 -3.o5 M -W Orilling, Inc. *P.O. Box 110389# Anchorage, AK 99511♦ 0907-345-4000 � 907-345-3287 Fax♦ GROUNDWATER WELL LOG Well Owner: Terra Nelson Legal Description: US survey 3202 Lt 22 Tso N R3.w Sec zo Drill Method: Air Rota Casing Size: 6" Well Completion: Open end Screen/Perforation description: Use of Well; Domestic CONSTRUCTION Hole Size: 6" Hole Depth: 3o6' Cased to: 52.46' Material: A53B Wall: 0.250 X Screen Perforated Method: Urout Notes: (3 ) Sack(s) of Bentonite Well Development: Air Surge Well Disinfected: Yes Method: Yield test at 3 GPM for s Method: Air Lift Start Date: 3/21/2os6 Test Pump Date: n/a bleach hour(s) with s00% of drawdown (DD) from static level(SWL). Static Water Level (SWL): 26' Completion Date. 4/2/2oi6 Final Pump Install Date: 5/10/2o3.6 WELL LOG Depth in feet from top of feet casi_° Details of formations penetrated, size of material, color and miscellaneous details. TO 3 Ca s i n g Stick Up 3 _ TO Pad fill gravel �5 To 37 Gravel: cobbs silk, dark grey" 37 To 42 _G ravel:grey, silty! wet 42 TO - 5o ---------- Gravel: silty, grey, 5o TO 3o6 Bedrock: water seepage in sporadic fractures TO TO TO TO TO President , MAW Oril[1ng,_Incz__ TO W4 A Certified Master Groundwater CanfMctat ----- ____ TO VVATER WA ITY TESTING— TO TO ---�+At:-des-_-_k�---M91L------ __ TO � rsQrtiic 3 ug/L 9/30/13 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion?  Yes  No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. X Ort -Site Water System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151193 Tax Code Number: 09002206000 Work Type: Well Initial Permit Effective Dates: January 15, 2016 to January 14, 2017 Design Engineer: Subdivision: US SURVEY 3202 Site Legal Address: US SURVEY 3202 LT 22 T1ON R1 W SEC 10 0:4760 Owner/Address: NELSON TERRA B 4401 MARS DR ANCHORAGE AK 995073720 Site Mailing Address: Lot Size in Sq Ft: 108900 Total Bedrooms: 3 This permit is for the construction of: N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing Special Provisions: The septic system shall be approved by the On-site Water and Wastewater Program prior to installing the well pump. MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On -Site Water & Wastewater Program Phone: 907 - Fax: ON-SITE SEWERNVELL PERMIT APPLICATION Parcel I.D. 6 70 OPoZ OC-QQ1) Property owner(s) 710(04 41e,4Oti- / Day phone Mailing address P6 sox l3 Iii/'�r✓aid ,4R 995g9 Site address Legal description (Sub'd., Block & Lot) _3-262 / 'j' .2.2 Legal description (Township, Range & Section) Lot Size (O 206 Sq. Ft. Number of Bedrooms S APPLICATION IS FOR: all that apply) Absorption Field 9 Septic Tank ❑ Holding Tank 9 Privy 9 Private WeII Water Storage 9 APPLICATION IS AN: Initial Upgrade Renewal 0 0 TYPE OF DWELLING: Single Family (SF) El- (w/wo ADU) Duplex (D) 0 Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: $9./5 Waiver Fees: Date of Payment: (o/Z�//5 Date of Payment: Receipt Number. *Receipt ' Receipt Number: Permit No. 4SP1514 Waiver No. Permit App_9-1-12.doc January 14, 2015 Planning and Development Services On -Site Water and Wastewater Program Municipality of Anchorage 4700 Elmore Road Anchorage, Alaska 99507 Re: 05P151193 for Terra Nelson Legal Desc: US Survey 3202 LT 22, T10N R1W, Sec 10 To Whom it May Concern: An approved COSA will be acquired after the new well has been permitted, constructed, and received operational approval. Please see attached email from James Crewdson dated December 14`h, 2015. Terra Nelson 907-202-3101 / / \ \ �, \ al (Qi, \ S9?r. \ or 2 N 2''996.0 N e�,rti �G•A/C \ a°98 \ cS q \ �'9�,y��J \92� SGeO N J / LOT 23 4 0 629Qti \ , 6 s90 29 N 2 '6 'IC* F`y29 3?96rmo. J 8312T LOT 13�0�9 to. \b07G O 11.0\ , 1 Story Frame House on Piles Top fdn= 122.7 aY / 6>e F k% a24 • 9 °O S"'000°///�0 Geo J LOT 14 USSI3680 52,718.6sf 1.21 Acres g: Corner not set or found Point falls on highway Qa f1/4 aoe LEGEND Found 2 1/2" Aluminum Cap Monument a Found Rebar with 1 1/2" Aluminum Cap • Found 5/8" Rebar (R) Record per Plat No. 92-8, Auriga Subdivision (R1) Record per U.S. Survey 3202 (R2) Record per U.S. Survey 3680 (M) Measured EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON. $s, Set lath on ry .0 fOr CS. g) t;i3 e) o li1tWell (Propo ed) LOT 21 V14cad od 9' x 22' CEA Easement (Serial No. 2008-036798-0) o \ / / property line \ at top of slope ACYo along Seward Highway oris \ sor o° ser\ 69° „ h o4'Sy CY � •C OF••: 111 % fir• •49th /\ * 0 BGG /1 •-/ /X c / iI 4% Fred Walatka: u of ow i `"at • 3255 - S •• e� $ �opess1oNA� ��• • Fb 07-2, pg 6-7 12 1 j S BE LOT 15 LOT 14 SCALE: 1"= 100' Note: Staking prior to construction REVISED 12-17-2015 ( PROPOSED CONSTRUCTION I hereby certify that I have surveyed the following described property: LOT 22, U.S. SURVEY 3202 and LOT 14, U.S. SURVEY 3680 Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage Alaska This 9th (907-248-1666) day of June 2014 FRED WALATKA & ASSOCIATES Engineers and Surveyors ;r. --;141111111W[01111111"111111: - {$193 :ReoQllldtnlDiet .3ot , r rIo age r . 6Y5%2(loli 2 29 PM Pe ei ;of IIIINII1111111111 I�ViNit IIIIE IIIIIIIUIII0l iI EC i,49.. q Ioa tilt/ xc { r�gUolege AlAsl'i# } ., 94.0f0 14 0,4 45`J% p4 0,': Int tea Im S et'��, +Ttttalt 'fit Alma Geta to naiad to a lard t'olootaaararr *IS Ata of Craw of Ate* 1. tier (ti OWL moi), is the raeeaaded 4i aealeadame 11, ado (T4 itst. W). owl tha aqs boatal threfe, tee *bola eed la V. 1. An* ate. 9aa, Maw as Oa Lasted WS* aft NS Crook Maebe, estatalig1.Ti won Now Us TT. that Om is. Om row ottani Us kata alatriv`y„*''*ys r toVflSOiDnoaktii STATER. ,Wa :ea thor dal t arrintrt,Wet as_ .11abtri. BOLO aTTOka Wad TTSCICTIOGTO PBL =MD A'APitt tor *taboo a* amnia 1. thud . Mt davit W. OraUSI atm 4,1 V to the 11. IL e1 the A 4 etsta-ol-ey *um tor tho Landsaaroa pguanslheranddire**oby th• Act at�u 151 3*bat. 3003. Mon MYioaar •ai al alicartaart peogiewee, saws art atm* aroma sad t MIPS Irai tho salsa as p abs � Ow'ar lilt a ,T. r highway MQwrlgnaw e Os 0a, amble alosaaattn, his" for a Niateia aLao ahaaart 7i. 1901. t1 Ns. Tao, 49 tt. i. can Lad 7e Waraee asthtebad at it Bums at thelaw of Jar rta t w e g Tat orm. MrydYeWydlatiratedYs ryshpiiiaK sad GS Sat at the ass to a Maar* 0. r ia¢ hat ho Aaiat � re.Air griginom Led . adisi mumeslab .Laarlr'tuav Starr as w • • • Boat 708 PROBE TN[ OnS w Zac yan Please return to: 82. Joseph M. Moran. Esq. MEEDES, SCHAIBLE. STALEY DeLISIO, INC. nEE:0776 943 W. Sixth Avenue Anchorage. AK 99501 Thank you. Amwa .nm r", r m, r m or.. .r. 010772._ .. t►IECWi °�' M4(»4ORACE REO DISTRICT - Iw 1113011'11- - LOUE81EOtYMOVES -1CTR r.apRESi F.:Sr ?$a -}{. 1 -`1142. SpurtAand Engineering Environmental Consulting and Design Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Subject: Septic System Inspection US SURVEY 3202 LOT 22 Ladies and Gentlemen: May 19, 2014 The owner of the above referenced property would like to apply for a land use permit to build a three bedroom single family residence. The property has an MOA approved septic system that was installed in 1976 to service a restaurant. The onsite file contains a permit application, a soils log and percolation test results, and an inspection report. The septic system consisted of a 750 gallon septic tank, a 1000 gallon septic tank and 36 feet of deep trench absorption field with 8 feet of effective depth. The septic system was inspected on May 19, 2014. Tank clean outs and a trench sump were located. The tanks appear to be full to the outlet levels and the trench sump was 70 inches deep and dry. Based upon this information, the existing septic system appears to meet current minimum standards for a 3 bed room single family residence. If you have any questions or concerns, please contact me at 279-3916. Si�acere y, r PSE.Q F ,A, <. , i•41 -i ' i7 vt ..ilTF J ars`Sp kland, F.E. Civil Engineer • SPURKLAND. E ,01 160 ' C7i 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspuridand r(Qgcienet Page 1 of 3 Crewdson, James A. From: Crewdson, James A. Sent: Friday, December 04, 2015 2:08 PM To: Walsh, Sharen A. Cc: Frost, Jack L.; Calhoun, Sonnet L.; Schutte, Christopher M; Rivera, Felix; Oswald, Tammy R.; Wockenfuss, Deborah M. Subject: RE: Letter from a Concerned Municipality Resident Sharen, The following history regarding well and septic on the subject property is what I'm finding in On -site's records. History: • 1976: On-site issued a permit to construct a septic system serving a "bar and cafe" at the subject property on 8/10/76. The system received final operational approval on 8/30/76. Note: although On -site's scope of regulation probably never officially included commercial properties, occasionally we will find where On-site was in fact involved with one. This is more common prior to the 1980's. • 2014: Lars Spurkland/Spurkland Engineering (deceased) appears to have been retained by the owner to inspect the septic system. In his report dated 5/19/14 he states the "existing septic system appears to meet current minimum standards for a 3 bed room single family residence". While his report is encouraging that the system may be approvable; it doesn't indicate that an adequacy test was performed on the septic system drainfield, which is one of the requirements for a Certificate of On-site Systems Approval (COSA). Per AMC 15.55 and 15.65, a COSA is required prior to the transfer of ownership for residential properties served by a well and/or septic system. Note: a COSA doesn't appear to have been submitted to On-site. • 2015: Terra Nelson applied for an on-site private residential well permit (OSP151193) on 6/23/15. Review comments were issued and emailed to her at tnelson0880(domail.com on 7/8/15. Per On -site's records, she doesn't appear to have responded to the review comments. Commentary: • On-site has discussed the issues with the owner and/or her fiance at the front counter on multiple occasions. I don't believe any of the discussions were in a documented meeting. • Deb Wockenfuss handled some of these discussions. I don't know the details of those discussions. Thanks Jay James "Jay" Crewdson, P.E. Civil and Environmental Engineer Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program Location: 4700 Elmore Road Mail: P.O. Box 196650, Anchorage, AK 99519 v. 907.343.7908 f. 907.249.7601 12/4/2015 GREA1Lk ANCHORAGE AREA BOROtiH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 Gem, $ ` r. INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME %/!/'C ForrFA/ MAILING ADDRESS Si& Bax /Ityr 4. 4,rcfi PHONELa /�/ / Sfryt LOCATION EGAL DESCRIPTION //��[1 /WOC /0 !�(7j /� �"/�r SEPTIC TANK: DISTANCE FROM WELL/ T MANUFACTURER r /ZQen- MATERIAI INSIDE LENGTH tt S 360 INSIDE WIDTH LIQUID DEPTH 7sof NUMBER OF /U�� COMPARTMENTS LIQUID CAPACITY GALLONS. TILE DRAIN FIELD: qq77 DISTANCE FROM WELLp2&D FOUNDATION /() NEAREST LOT LINE /0/ NUMBER OF LINES (`� DISTANCE BETWEEN LINES /j'/� TRENCH WIDTH ABSORPTION AREA ' SQ FT LENGTH OF EACH LINE 3`-'� / DEPTH OF FILTER,, DEPTH: TOP OF TILE TO FINISH GRADE / MATERIAL BENEATH TILE _L4ABOVE TILE � IN WELL: No 2,2,11E D wic// f 057i0i4- TYPE CONSTRUCTION DEPTH DISTANCE FROM: TOTAL LENGTH, OF LINES TOTAL EFFECTIVE /lmv6a Due- it -V// BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE SEWER LINE TANK SYSTEM CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES' INSTALLED BY• C//Ae/P S1,-771 SEWER LINE DEPTH PIPE MATERIAL' LOT SLOPE I/C� REMARKS Form EQ -032 fO ��SDIAGRAM OF SYSTEM N DATE3O177 APPROVED G.A.A.B. ofc / . 3- r /moo (-�o. o GREATER ANCHORAGE AREA BOROUGH r DEPARTMENT OF ENVIRONMENTAL. QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM — APPLICATION AND PERMIT NAME OF APPLICANT d A c, c/( Fr,e, e INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK ''&/ y/ MAILING AD DR E SS547/ 99)C /f/i" PHONE7Vt 25-9/ Aro & t TYPE AND SIZE OF FACILITY TO BE SERVED SEEPAGE PIT - DRAIN FIELD I / Q / c/cJ TO BE INSTALLED BY 1 -� c'k ��o` /Y->�y,C4 �ncxA U FINANCED THROUGH SOIL TEST RESULTS iro , OTHER7/I C,C fru- COMPLETION DATE ANTICIPATED i o /" CJ -t; r..f A/ NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL. INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL. BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE / 07-0 TYPE SEEPAGE AREA SIZE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK TO NEAREST LOT LINE. SEEPAGE PIT DRAIN FIELD WELL TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD SEPTIC TANK. . SEEPAGE PIT DRAIN FIELD TO RIVER. LAKE. STREAM. o- DIAGRAM OF SYSTEM TYPE / eevcrt ri✓ y—'c' 7 CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER A DESCRIBED SYSTEM 15 IN ACCORDANCE WITH SAID CODE. DATE (� —7 ,C APPLICANT'S SIGNAT ORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE Sanitary Sewer Test Hole Benny Garcia Bennies Paradise Seward Hwy DWN: MAIZ CKD: DATE: SCALE: 1"=3' V RSM CONSULTANTS, INC. T.H. 1 7/31/76 ORGANIC MATERIAL 1' SILT W/SOME GRAVEL & TR SAND 6.5' SILTY SAND W/TR GRAVEL & OCCASIONAL COBBLES @13' 13' SILTY SAND W/SOME GRA\pC 18:5' T:D. NO WATER TABLE W.D. This log represents subsurface'; soil conditions within Bennies • Paradise. Seward Highway F. B. GRID PROJ.NO. 656277 DWG. NO. r 0' � RaM CONSULTANTS, INC. 248 EAST 51 ST. AVE. • OOX 8007 • ANCHORAGE, AK. 02002 • P.N. 807278. 0423 • TLX. 0E10.2 3130 August 5, 1976 R & M No. 656277 Benny Garcia Bennies Paradise Seward Highway Anchorage, Alaska 99507 RE: Test Hole and Soil Log Report for Sanitary System Bennies Paradise Seward Highway Dear Mr. Garcia: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of July 27, 1976 and those procedures outlined in a letter dated July 15, 1975, by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the subject site area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with an auger type drilling rig and the test hole was extended to a total depth of 18.5 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole while drilling. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, IINNC. ) (7,41:AALLA C-1 James W. Rooney Vice President ,ll5 i.' JWR/ddp xc: GAAB ANCHORAGE FAIRBANKS JUNEAU TIME 10:00 10:01 10:02 10:03 10:04 10:05 10:06 10:07 10:08 10:09 10:10 10:15 10:20 10:25 10:30 10:40 10:50 11:00 PERCOLATION TEST BENNY GARCIA R & M NO. 656277 ELAPSED TIME 0 1 2 7 8 9 10 15 20 25 30 40 50 60 60 Minutes DROP IN INCHES . 5 .5 0 .25 .25 0 .75 . 25 . 25 .75 . 5 . 5 5.50" Total Drop 7 / /14 /NA/6JY