Loading...
HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 24CEogle River Vail Y Ranchettes Lot 24C #050- 2 2 3 - 11 Municipality of Anchorage Development Services Department n,~ u~ ...~' ~ Building Safety Division On-Site Water & Wastewater Pr°gram' 4700 Bragaw St' ~ 1 P.O. Box 196650 Anchorage, AK 99519-6650 ~ ~- www.ci.anchorage.ak.us (907) 343-7904 0 P of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: 0SP1010`36 PID Number: 050-22,3-11 Name: CHRIS PAULEY Wastewater System: [] New · Upgrade Address: 18709 WHIRLAWAY DR, EAGLE RIVER, AK, 99577 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 694-2506 4 [] Deep Trench · Shallow Trench [] Bed E]Mound []Other LEGAL DESCRIPTION so,, ,ating: 0.8 GPO/Sq. Ft. Tot°, Depth frOmsEEO,iginO,DwG.grade: Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: - 24C EAGLE RIVER VALLEY RANCHE-FFES SEE DWG. Ft. 4 Ft. Township: Range: Section: ~ill added above orlginol grade: Grovel length: - - - SEE DWG. Ft. 76 (57 & 39) rt. J Gravel width: Number of lines: Dietanc~ between lines: WELL: [] New [] Upgrade 5 Ft. 2 O+ Ft. Classification (Private, A,B,C): Total Dept~b;~ Cased TO:(BEDROCK) Total absorption area: Pipe material: ? ~¢¥~-~/~ Ft. Ft. 760 SO. Ft. D 5054/ F-810 Driller;. Date Drilled: Static Water Level: Installer;. Dote installed: Ft. PACIFIC SERVICES 6/1 6-18/2010  I Pump Set At: Casing Height Above G .... d: cP.I rt. Ft. TAN K SEPARATION DISTANCES · Septic [] Holding [] S.T.E.". [] Other* T~.~'~-......~To Septic Absorption Lift Holding Public/Private Manufacturer;, Capacity in gallons: Tank Field Station Tank Sewer Lines GREER TANK 1250 Material: Number of compar'[ments: Well 100'+ 100'+ - - 25'+ STEEL 2 Sa.ace Water 100'+ lO0'+ - - - LIFT STATION _ _ _ Size in gallons: j M~rl~ Lot Line 5'+ Foundation 5'+ 10'-{- -- -- -- "Pump on" level at: ~at: High water alarm at: Curtain Drain = NONE KNOWN . Purnp~ Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: *WAIVER GRANTED #0SP101041. BOTYOM OF SIDING, SW CORNER OF HOUSE NOTE: OLD 'FRENCH AND TANK WERE ABANDONED A~sumed Elevation: IN PLACE PER UPC. 100.00 Ft. ENGINEER'S SEAL Inspections performed by: GEG, Ltd. Dates: 1st 6/16/2010 3rd 6/18/2010 ~ ' ¢ ,~, '-.0-~. r-, TU Development Services Department Approval '*' '~:':' '% '~'~' '/J2 Conditional approval: Date: ~^~J//~r 'PERMIT NUMBER: AS BUILT DRAWING PARCEL ID NUMBER: OSP1 01 0,56 - 050-22,5-11 NOTE: OLD TANK AND TRENCH WERE ABANDONED EXISTING WATER MAIN IN PLACE PER UPC. I WATER KEY BOX-x EXISTING CRIB (APPROXIMATE ~ ~ :~.~..~ -- x~ LOCATION) RESERVE CONNECTED SITE AS] -'""~ ~ ~ ~ ~ \\\ II \\ A B C I · \ ~ /-- D~BL4 FCO 14.89 5.25 55.27 ] 5' LOT LINE \ ~,4.'¢'-:DBL3 DBL1 13.60 7.46 37.90 WAIVER --.,- ~__',~M .... I GRANTED - FD.SV'"~'X? I / I DI~I/"II~ Tn / ~ ~ NEW 1250 GALLON ......... ST1 DBL2 14.43 6.72 37.65 :3 --CONSTRUCTION / X',o~ST1 SEPTIC TANK I I /- ST1 23.24 15.06 49.14 J '~_~-"~'o,~ I ST2 30.93 21.79 55.85 I' i~-c~", I ~ FCO~ I DBL552.9423.6257.45 ]l__k~.~ 0o3 p q co1 B AL_____~i~]i] DBL4 34.40 24.09 57,94 I: I I I I~1 I I FD ,35.05 24,54 58.26 '] I I I I FS 44.93 24.20 42.90 I I I I EXISTING f IMT2 b IMT1 4 BEDROOM C01 _44.11 24.29 41.17 ! I.~ I I HOUSE MT1 51.70 34.48 30.43~ TH#1 II I I c C02 60.54 47.52 25.79 I I I I rh ' '"~" "i ,;, ' I-"C04 L~,Ic02 T .' :. .. · CO5 59.53 ,39.80 50.90 ri ~ / .... I '"'? ' ":'" ": MT2 64.97 46.49 44.41 / ~ ~ .' 2"'!~' ' NEW DRAINFIELDS~~'--FENCE LINE WHIRLAWAY ROAD I I GARN'ESS ENGINEERING GROUP, Ltd. PREPAREDCHRIsF°R:PAULEY PHONE 694--2506NUMBER: I PAGE2 N.MBER:oF ,5 LEGAL DESCRIPTION: DRAWN BY: IAI/ CE;-79,5,5 ..' EAGLE RIVER VALLEY RANOHETTES; LOT 240 A,J,G, DATE: less' TYPE Of WORK: AS-BUILT DRAWING OF NEW SEPTIC SYSTEM 6/28/2010 A B C FCO 14.89 5.2,3 35.27 DBL1 1,3.60 7.46 `37.90 DBL2 14.4,3 6.72 37.65 ST1 25.24 15.06 49.14 ST2 50.95 21.79 55.85 DBL5 52.94 23.62 57.45 DBL4 54.40 24.09 57.94 FD 55.05 24.54 58.26 FS 44.95 24.20 42.90 C01 44.11 24.29 41.17 MT1 51.70 34.48 30.4,3 C02 60.54 47.52 25.79 C03 59.53 `39.80 50.90 MT2 64.97 46.49 44.41 C04 71.79 56.22 40.,37 (Rev. 01/05) AS BUILT DRAWING OSP1 O10,36 - 050-223-11 ST1 F FIN~2GRADE = 99.31-99.3,:7, TOP OF TANK IN r=l I r=l /--- TOP OF TANK WEST TRENCH MT CO / EAST TRENCH FINAL GRADE -- MT CO /--FINAL GRADE = 96.89-97.62 GRADE / 97.07-98.45 0 TH#I = 94.00 FABRIC TH# 1 FABRIC INVERT OF PIPE INVERT Of PIPE = 92.00 = 92.00 I 5' t OF BO~OM OF I' TRENCH = 88.00 TRENCH = 88.00 RELATIVE ELEVATION OF Bo'FrOM Of TESTHOLE = 82.00 (DRY) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 * PHONE (907)337-6179 * FAX (907)338-3246 * WEBSITE: www.gamm~Benginemitng.com PREPARED FOr: I PhOne NUMBER: PAGE NUMBER: CHRIS PAULEY I 907-694-2506 ,3 OF ,3 LEGAL DESCRIPTION: DRAWN BY: EAGLE RIVER VALLEY RANCHETTES; LOT 24C A.J.G. DATE: TYPE OF WORK: PROfILe AS-BUILT OF NEW SEPTIC SYSTEM I 6/28/2010 (Rev. 01105) On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101036 Tax Code Number: 05022311000 Work Type: Septic Upgrade Permit Effective Dates: May 27, 2010 to May 27, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivlslon: EAGLE RIVER VALLEY RANCH[-. I ~ ES Site Legal Address: EAGLE RIVER VALLEY RANCt-lt: i 1 ES LT 24C G:0054 Owner/Address: PAULEY RICHARD E & PATRIClA L 18709 WHIRl. AWAY RD EAGLE RIVER AK 995778334 Site Mailing Address: 18709 WHIRLAWAY RD, Eagle River Lot Size in Sq Ft: 17955 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections dudng the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either. A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: FINISH GRADES SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM THE DRAINFIELD. Permit includes waiver OSP101041 allowing the drainfield to be 5 feet from the west proper~ line. Munic a of Anchorage ,~.a ~,. P,O. Box 196(~50 · 4700 ~lmore Road ~~"- · IJepar tment Anchoraqe, Alaska 99519-6650 · (g07) 343-7904 · Fax {907) 343-7997 htr p:l/www.munLorg/O nslte Development ,Services Department On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** WP~: OSP101041 HA#:~ Permit~: OSP101036 PID#: 050-223-11 Legal Description: Eaqle River Valley Ranchettes, Lot 24C Engineer: GEG Applicant: Chris pauley Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 5 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: ~ Waiver Is not Granted: Date' ~7/2010 Approved by: +'~Na m~e of Reviewer Rec#: (~61727 Amount: ~;200.00 Date Paid: 5119/2010 **** VARIANCE/WAIVER REVIEW **** Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERI'lIT APPLICATION FOR ~, SINGLE FAHILY DWELLING - Property owner(s) CHRIS PAULEY Day phone 694-2506 Mailing address 18709 WH1RLAWAY ROAD. EAGLE RIVER. AK Site address Zip Code 99577 Legal description (Sub'd, Block & Lot ) EAGLE RIVER VALLL='Y RANCHETTE$: LOT 24C Legal description (Township, Section & Range) LotSize 1'7~, ¢~55 Sq. Ft. N/A Number of Bedrooms 4 THIS APPLICATION IS FOR ( []all that apply): Absorption Field Septic Tank Holding Tank PriW [] Pdvate Well [] Water Storage [] THIS APPLICATION IS AN:  Initial Upgrade [] Renewal I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. CARNESS ENGINEERINC CROUP, Ltd. Permit/Rush Fees: Date of Payment: Receipt Number. (Re',,. 11/05) Waiver Fees: Date of Payment:.,.~//"J / / o Receipt Number:, GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS- May 17,2010 MunicipalRy of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for Eagle River Valley Ranchettes S/D; Lot 24C, To whom it may concern: The existing 4 bedroom house is served by public water and a private septic system. The septic system is in a state of failure and needs to be upgraded. We are proposing that a new 1250 gallon septic tank and dual 5-wide trench type drainfields be installed. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius ofthis test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows thc soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet ofthe proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing, the test hole was excavated in a Iow area on the propen3t. The average topography in thc area is a 5 to 15 percent slope running generally east to west. There are no cutbanks within 50 feet downhill from the proposed drainfields. Since the test hole was excavated in a Iow lying area, we are proposing to base the drainfield elevation on the original grade at the test hole. See Ihe attached detail drawing for the proposed drainfields elevations. In short, there are no slope concerns. 5. LOT LINE WAIVER REQUEST: We request that a .5 foot lot line waiver be issued from the west property line to the proposed drainficld. We are unaware of any adverse effects on the neighboring property with the granting of this waiver. We are unaware Rfany adverse impacts this installation would have on adjacent wells or septic systems. any qci~Stions~t~Te contact us at 337.6179. Thank you for your assistance. ~ Jamess//~ P.E., M.S. NOTE: dttached is a site plan drawing a design drawing a detail drawing, and one soil log. which are all part of the design package for this septic system. (Contact G.E.G. Ltc~ for 7 page construction specification letter.) Ifyou have 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Wcbslte: www.gamcsscnginccring.com /[ ./ /.C .................................................................................. /.~.. ........................................................................ ~, r .......... ,I // (/' I ALL LOTS SERVED BY PUBLIC WATER.I J J I ALL LOTS SERVED BY PUBLIC WATER.J J J (~[ OESIGN. P~ 2 Or 3) ~ _J~"-" ~ ~ v~ ~ ~ v~ , J ~R ~TH/I WHIR~WAY ROAD I ALL LOTS SERVED BY PUBLIC WATER.I J, J, ~. EZZ ...................................................................... ,~ ......... EAGLE RIVER VALLEY RANCHE~ES,' LOT 24C J.L.M.~~X'~h'~ff~* ~Hq I¢ ~/. '..lYD.{ "~/ SlIE P~N FOR PEOPOSED S[PIIC UPGRAD[ 5/19/2010 I ~ '~ I ~~////~ ~T~ I HO~ I WHIR~WAY ROAD GARNESS ENGINEERING ~ROUP, Ltd: [~~ , CONSULTANTS & OENEUL CONTUCTORS CHRIS PAULEY 694-2506 2 OF 5 EAGLE RIVER VALLEY RANCHETTES; LOT 24C J.LM. ~gK OF PROPOSED SEPTIC UPGRAO[ FROU SEPTIC TANK ~ . ~KST. a, LX. FLOW SPU1TEJ I .xS' LONC I /, -/-"' ~4' CLE~NOUT ONITOR~NG TUBE I 38' LONC I I O.[ANOUT Z~ OUT ONITORIND TUBE BENCHMARK IS TOP OF DECK AT NORTHWEST CORKER OF HOUSE w t00,OO 4' OF tO' O.O.H. - 82.00 NO GROCSNDWAT[R GARNESS ENGINEERING GROUP, Ltd. ~gJ~ ~."l zj CHRIS PAULEY 694-2506 3 OF' 5 · CE-7955 .."~.'~'-/~/ ~ - ~[~CO~ON ~S~ , PERfORmED FOR: CHRIS PAUL~ DAIE:~~$t "-.~]~ ~EPIH ~ I IFI ATI N ~ ~w ~ o~ ~GH ~ CL GE OL SW HH i SP CH ~ s. o. SEE ~TT~CHED 1[1111 DEPIH TO D~IE GROUNDWATER D~ 5/12/2010 D~ 5/13/20~0 ~ ~/~/,~ 11 DAlE READING CLOCK NET IIHE WATEE LEVEL NET DEOP IIHE (HINUTES) READING (INCHES) 5/1~/20~0 ~ ~:27 - 6- - 12 HARDPAN 2 1:57 30 2' 4' 1~ 5 1:57 -- 6- - 4 2:27 30 2' 4' 14 5 2:27 - 6" - 6 2:57 50 2' 4' 15 16 17 18 19 PERCOLATION RATE 7.5 (MIN./INCH) PERC. H~E DIA. 6 .(INCHES) TEST RUN BETWEEN 4.0 FT, ~D 5,0 FT, 20 A FOUR HOUR PRESOAK WAS PERFORMED: ~ YES D NO SOILS LOGGED BY: ROB ~MPBELL PERCOLATION TEST PERFUMED BY: JODY MAUS COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFR~ A, ~RNESS, CERTI~ T~T THIS W~/PE~ORMED IN ACCORD~CE WITH ~L STATE ~D MUNIClP~ CUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER DRY 5/12/2010 DRY 5/13/2010 o~-~ ¢/~/,o CPRE:A'~Efl ;LT~U-~ZOflAG~. A.~I~A BOflOTtl~IJ~.~R ANCHORAGE AREA BORO~-G~.~i Departmn~,.t of Env~on~ental Qual~t~ I ~ ...... " INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTE~ NAME Jlnel y' izo~ ~.s ADDRESS II LOCATION...k)hf~:Zn~fl/ ,,.~'~' ~O~;l~ ~1'lN'r'- LEGAL DESCRIPTIONE~.~ ~!'l,~v'" ~._/~/,,j ~/,..~//~7'/~,3 ~7' ,~'~/d SEPTIC TANK: NUMBER OF DISTANCE FROM WELL ~l:~'~m(4 ~l~ MATERIAl, ,,~'~'~/Z ,S"ZZ.,~rL COMPARTMENTS LIQUID LIQUID CAPACITY j~O GALLONS. INSIDE LENGTH ~ INSIDE WIDTH ~ DEPTH SEEPAGE SYSTEM: NUMBER OF PITS LINING MATERIAL NEAREST LOT LINE SEEPAGE PIT: OUTSIDE DIAMETER ~ OR WIDTH ,~--.~ , DISTANCE FROM WELl ("/~'I~'/~/'fl. TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) LENGTH, .,~,ff ! , DEPTH · BUILDING FOUNDATION,~ '"f'. ,SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL TOTAL LENGTH ., FOUNDATION, . NEAREST LOT LINE :O~'~INES. ., NUMBER OF LINES ABSORPTION AREA TRENCH WIDTH IN. TOTAL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE~ WELL: DISTANCE FROM WATER TYPE-- ~''C~4~ DEPTH ,BUILDING FOUNDATION.~SAMPLE . NEAREST NEAREST SEPTIC SEEPAGE OTHER LOT LINE .. SEWER LINE ,TANK . SYSTEM · CESSPOOL, /~r,~/~; . SOURCES DIAGRAM OF SYSTEM DISTANCES: ~L. GREaTE~ ANChOragE ArEA BOruU~h DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 TELEPHONE 279.8686 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT .NSTALLAT.O. LOCAT,O. INSTALLATION OF: ~EPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH COMPL~ION DATE ANTICIPATED SEEPAGE PIT ~ DRA~N PIELD OTHER TO BE INSTALLED BY FINAL INSPECTION; 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION ElY THE HEALTH DEPARTMENT AUTHORI"rY WILL ElE EIUEIJECT TO PROSECUTION. ./ MINIMUM DISTANCES. REQUIREMENTS FOUNDATION TO SEPTIC TANK , FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL DRAIN FIELD / / SEPTIC TANK _~l TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD , SEEPAGE PIT DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD ~'"'~EpAGE AREA SIZE TYPE DIAGRAM OF SY~TE:M , SEEPAGE PIT ~ ALSO CONSIDER AREA WELLS, SEEPAGE PIT SEPTIC TANK, SEEPAGE pit TO RIVER, LAKE. STREAM. , . DRAIN FIELD CAST IRDN INTO AN~ ~H't' m; ;Fr~:[[~K AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 It~-~HrF. T~.~ ~l I~U~ =~tPNON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WIT~ AIRTIGHT REMOVABLE CAPS. ._~..__..---------- G~ R A V E_L,___EI_A C K F:'_.l L L CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF (:~REATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE 327 EAGLE STREET ANCHORAGE, ALAgKA'99501 . '' Feet Soil Characteristics 'Loeatiun Sketch {~as Ground Watex, 'Encoun~,e~-ed? ~.~ ~) %"es, At W~ Depth ........ Net Time Reading Date Gross Time Depth To H20 leer Drop Proposed 2nstal-l~tion{-Seepage Pl~ I/ Drain Field Depth'Of Inle~ ~' De-~h T~ -Boy .......... - ' ' Test Pcrfor~d Bj,t ' *' · Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS FoR A Parcel I.D. 050-225-11 1. GENERAL INFORMATION APPROVAL SINGL'E'"FAHILY DWELLING cos^ o 1/ Expiration Date: ~ Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address EAGLE RIVER VALLEY RANCHE'FrES S,/D; LOT 24C 18709 WHIRLAWAY DRIVE * EAGLE RIVER, AK * 99577 CHRIS PAULEY Day phone 694-2506 18709 WHIRLAWAY DRIVE * EAGLE RIVER, AK * 99577 Day phone BARBERA CRITTENDEN W/ PRUDENTIAL Day phone 689-1802 16655 CENTERFIELD DRIVE * EAGLE RIVER, AK * 99577 Unlessotherwiserequeste~ COSAwillbeheldbyDSD ~rp~kup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System · Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wasteWater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application; shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the '~ on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a tttorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MQA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE }.<~Approved for Disapproved. Conditional approval for bedrooms. ~,~- WATERAND :m.'E == W STEWATE :' bedrooms, with the fllowing stipulation~ ~ PROG~M .- ~' ~ ~] ~ ~ ) ), "~ Il )~~ ' Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) /-1,1 S~;;I IlL/ /-~U V |~:~UI ~ Maintenance Agreements Supplemental Engineer's Report' Other Original Certificate Date:, '/"//,- / ,.~ / / Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: EAGLE RIVER VALLEY RANCHETTES S/D; LOT 24C Parcel ID: 0~'~ ~..'2, ~,.~3-// A. WELL DATA [PUBLIC WATER ] Well type If A, B, or C provide PWSID# __ Well Log (Y/N) Sanitary seal (Y/N) Wires properly protected (Y/~...-~ Cased to ft. Casing he__round) in. FROM WELL LOG AT I.~CTION ft. ~ ft. ~~O~p.m. g.p.m. Date completed Total depth Date of test Static water level Well production cWo::oEr: SAMP~ ~ ug./L. Nitrate __ mg./L. Other bacteria __ Date of sample: Collected by: colonies/100 mi. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 6/16-18/2010 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping NEW Pumper Co ABSORPTION FIELD DATA [*BELOW FINAL GRADEI Date installed 6/16-18/2010 Soil rating ~or ft2/bdrm), 0.8 System type DUAL TRENCH (37 & 39) Length 76 TOTAL .ft. Width 5 ft. Gravel below pipe 4 ,ft. *8.9-9.6/ Total depth *9.1-10.s ft. Eft. absorption area 760 ft2 Monitoring tube YES Depression overfield NO Date of adequacy test NEW Results(Pass/Fail) PASS For - bedrooms Fluid depth in absorption field before test - in. Water added - gal. New depth - in. Elapsed Time: - min. Final fluid depth - in. Absorption rate >= - g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date - D. LIFT STATION Date installed "Pump on" level at Size in gallons Manhole/Access ~ ~ in. "Pump off" leveJ.~-~ High water alarm level at ,in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer_/s~ Ap, imat-C'Sntainment areas. On adjacent lots On adjacent lots ~eanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *5'+ Building foundation. 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ Water main. 10'+ Driveway, parking/vehicle storage 10'+ COMMENTS *WAIVER GRANTED, #0SP101041. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date COSA Fee $ ,,-~ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number ASBUILT HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: AND THAT NO ENCROACHMENTS EXIST EXCEPT AS IND!CAT'ED. IT IS THE RESPONS!r-51LITY OF THE OWNER TO DETERMINE TH,E EXISTENCE OF ANY EASEMENTS, COVENANTS., OR REf)TRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSf'r'RUCTION OF FENCE LINES, OR FOR ESTABLISHING BEYJND- ARY LINES. SCALE: DATE, GRID: