Loading...
HomeMy WebLinkAboutAUTUMN RIDGE LT 12Autumn Ridg #015- 054-15 Municipality of Anchorage Page Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343,7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW020263 PID Number: 01].5-054--1 5 Name: Crown Pointe, Inc. WastewaterSystem: New 5400 Abbott Road Anch., AK 99507 ABSORPTION FIELD 345-6277 Six (6) Deep Trench LEGAL DESCRIPTION .6 c.~,, 13 12 Autumn Ridge 3 F,. 10 1 r,. 77 Well: New ~ r~. Private 62 r,. 62 r,. 1,540 re ASTM D3034 PVC Alpine Drilling 9/11/2002 46 Ft. Sanders & Sanders 8/8-9/2002 Y""~: 15 G.. I~''"" ~'':F,. lc,..,, .~.,,~,. ~.o..d:2 F,. TANK SEPARATION DISTANCES [] Septic I-I Holding r"l S.T.E.P. D Other:. Fmm~ Septic Absorptior Lift Holding ~ublic/Pfivate Manulaclurer; ~apac~l¥ m ~al~on$: Tank Field Station Tank S~,,~rUr,, Anchorage Tank 2,000 We,, >100' >100' N/A N/A >25' Steel Two (2) s~.:.w.,~, >100' >100' N/A N/A ~~./~ ~,~o. LIFT STATION. a~..~,~,.,: - NONE ON LOT ~,~ >5' 4' N/A N/A Fo,.d.,o, >5' >'10' N/A N/A 'Pump on' level at: 'Pump O/r level al: [ H~gh wale, alarm al: c,,,~,o,,~ None Noted Pump Make & Model Electr~callnspecluonsperformeclby: See Lot Line Waiver. BENCH MARK Lower Level Floor. 100.0 Engineer's Stamp e -\ ........ :...v.. ~, c..-:.." . ";~r:_.'~. .- 49th . · Inspections performed by: MEA Dates: 1't 8/8/02 2"~ 8/9/02 Department of Health and Human Services approval %~4. '.. --..." _~.~ ~ Reviewed and approved by: &/z~ ../' /4fid /c::::)/'c/'-~Date: ¢- q' ~ ~ Permit Number. SW020263 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report PID Page 2 of 3 C4 TH 49 ~l,.-. FINCh: (~,PX) N 90'00'00#E 10' T. &: E. Six Bedroom Home ~ TH 48 iA S1 57.1 S2 I 71.4 C4 11 12.9 C5 J 74.7 M1 ~106.6 u21 75.1 WELL ~ ~'~ N 9CT00'00"£ 157.95' B 50.6 59.8 83.2 81.7 78.8 79.1 Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-79~4 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW020263 PID No.: 015-054-15 ~-86.3 2000, ~*ttOn~< 80.5 69.9 / / 64.0 IL~eo~c e x 1;lie 84,0 .Fo__bric ............. Orninf'ietd Rock 80.5 77' / 69.9 / PROFILE AS-BUILT Scale: 1" = 10' FRgl~ ALPINE DRILLING FAX NO. : 907 345 0202 $~n. 0@ 2003 Og:44P, H P1 Borehole Data: Soll Type, Thickne~ & Wa~cr Stm~ Municipality of Anchor. age Department of Health and Human Services 825 'L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 R/ck Mysttorl/ http:l/www.cLa nchomge.ak.us Mayor Permit l~umber:. #SW 020263 Date of Issue: 6-31.02 Parcel Identification Number:_016~64~16 Date Started: 9-71.02 Date Completed: 9-1'/-02, Is well located al approved p~mlt location? [] Yes [] Legal Description: Autumn Ridge Lot,,!2, Property Owner Name & Address: Ctowo Pointe Inc. PO Box 112313 Anchorage, Alaska 99511 ., ,,, Depth (ft) Method of Drilling [] air rotary [] cable tool From To t:tiek-.uo 0 ~ silt 2 3 silty gravel 3 52 gravelly silt 52 58 water sand & gravel 58 62 Casing type: Steel ~nmeter: _Umches ~epm: u.~ zeet Liaer Type:_ . Diameter: inches Depth: feet Casing sfickup above ground: _.2 feet Static water level (from ground level): 46 feet Pumping level: 62 feet after _2 hours pumping ~ gpm Recovery Rate: 15 gpm Method of Tcsting: glr. Well Intake Opening Type: [] Open End r-I Open Hole I-] Screened Sta~ feet Stopped feet [] Perforations Start feet Stopped feet Grout Type: bentgnite # 8 Volume: 1 Depth: Start O feet Stopped feet Pump: Intake Depth feet l~rmp size hp Brand Name __ Well Disinfected Upon Completion? [] Yes [] No Method ofDisinfectlon: chlodne tablets Comments: Well Driller:. Alpk~e Drilling 8. Eoterprisss Anchorage Alaska 99511 Attention: The well ddllex $hall provide a well log to the property' owner within 30 days of completion and the property MUNICIPALITY OF ANcHORA GE Development Services Deparfment On.Site Water & Wastewater Program 4700 South Bragaw Street P,O, Box 196650, Anchorage, AK 99519-6650 (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jul 31,2002 Expiration Date: Jul 31, 2003 Permit Number: SW020263 Legal Description: AUTUMN RIDGE LT 12 Design Engineer: 0014 Anderson Engineering Owner Name: Crown Pointe, Inc. Owner Address: PO Box 112313 Anchorage, AK 99511- Parcel ID: 015-054-15 Site Address: 009410 ZIEMLAK ClR Lot Size: 43925 SQ. FT. Total Bedrooms: 6 Permit Bedrooms: 6 This permit is for the construction of: [] D sposa Fie d [] SepfioTank [] Ho dingTank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWEPJVVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D.Ol '" Permit Number swOZ, OZ~'=J Property owner(s) Crown Pointe, Inc. Mailing address (1) P.O. Box 112313 Anchorage, AK 99511 Mailing address (2). Legal description (Lot, Block & Sub'd.). Lot 12, Autumn Ridqe Subdivision Legal description (Section, Township & Range) Lot Size 43~ 925 s~' Acres/Sq.Ft. Day phone 345.6277 .Zip Code Number of Bedrooms Six (6) THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I cedify that the above information is correct. I fudher cedify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: ,.~ Date of Payment:, Receipt Number: (Rev. 12/00) Waiver Fees: L Date of Payment: Receipt Number: :'i:.:.:;:-:! i;':~ :P.O.' BOX 240773 ~,": ::: :::!ANCHORAGE,: AK 9D524 ~:522'7773';.:!~!:?::: i.522-6779 (FAX) July 23, 2002 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 12, Autumn Ridge Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer:. The owner of Lot 12, Autumn Ridge Subdivision intends to construct a six-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new well and septic system and the parameters used in the design. Also identified on the plans are the test hole locations and the locations of the wells and septic systems on the adjacent lots. Drainage arrows are also shown and current drainage patterns will be maintained after construction. Spot elevations are also shown on the Site Pian. The test holes placed near the location of the proposed absorption trench and alternate site indicated silty sand and gravel with varying amounts of silt and a percolation rate varying from 15 to 35 minutes per inch. We are using an average application rate of .6 gallons per minute per square foot to design the new absorption trench. No groundwater was found dudng the placement of the test holes and none has been noted since. We are therefore proposing to construct a 3' wide deep absorption trench with 10' of drain field rock beneath the distribution pipe. The total depth of the trench will be 12' with the distribution line at 2' below the surface. The total length of the trench will be 75'. The ground surface on the lot slopes as shown on the attached Site Plan with fairly steep slopes in the area of the new trench. The new absorption trench will be constructed in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new trench will be constructed a minimum of 100' from the well on the lot. The system will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: Lot 12, Autumn Ridge July'23, 2002 Page Two The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 3,'7 2 '"N:'o~.. / DEDICATE TO F .+.~¢~' ..... i ..... 4O. lO8 ft. V~.x ' x. 2 _~ .>. / '". / '~¢5 ,/' .,..,-- \ \ ~ '.__3 -- ...... ---Sg,O49xsq. ftc. 2 ! '~ ~1-37. %-, 3 '/'"' ~ 31 "" "' ",IH- 3.~ .~ THIS PROJECT -. -. -.' ..~.. ' ' ",. ", '" 49th 3 AREA SYSTEM PLAN "' "' '"' -~""".. SCALE 1" = 100' I '- '- 110' 2O% 50! I .,.~0' X 2,000 Gallon Septic Tank Lonq X 3' Wide Six 0' Effective De Bedroom Absorption Trench Home Z ' ; SITE P=L6N "'~ I I '11 :~E~---~ ~o J LOT 12, AUTUMN RIDGE SUBDIVISION DESIGN FACTORS: Six Bedroom Home Perc. Rate: 15 to 35 MinJInch Avg. Application Rate: .6 GPDISF SYSTEM REQUIREMENTS: Deep Trench System 2,000 Gallon Septic Tank 10' Drain Field Rock 6 Bedrooms X 150 GPD 1.6 GPDISF = 1,500 SF of Absorption Area 1,500 SF/20 SF/LF = 75 LF Trench Length Therefore: Construct an Absorption Trench 75' in Length by 3' Wide With 10' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 2' Below Existing Ground. Total Depth of Trench to Re 12' Below Existing Surface. Cover Over Septic Tank a Minimum of 4' or 2" of Insulation and 2' of Cover NOTE: TYPICAL DEEP TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' From Lot Line. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 10' Separation From Water Service Line. Municipality of Anchorage ~,.~...~ ..... ./~....~.--/.].,. . Depa~ment 0f Health & Human Se~ices ~~.~ ' 825 L S~t, Anchorage, AK 99502-0650 ~ SOILS LOG - PERCO~TION TEST . . . ~ ~,~... ..- ~,~ Pe~orm~ For: Dob Klein Date Pe~orm~ Legal D~c~ption: Lot. 12. Autumn Ridge Su~ivision SLOPE SITE P~N 5 ~ .-. ~~ · .'.. . ' '7 g . Was Gmun~ater 9 E~unter~? No S If Yes, ~t Depth? . '. L · 10 Depth to Water O Afl~ Monitoring None P 11 ~ 'SM · Date: · 1~00 " "E Reading Date Gross Net Depth To Net 13me 'i~me Water ' .IDrop · ' -1 - 9-Dec 1:04 2.5" 2 1:34 .30 5" · 2.5" 3 . 1:34. ~.5" 4 2:04 30 4.5" 2" · 5 2:04 2.63' 6 2:34 30 4.63" I. · ".2" ' .12 14 ." 15 18 Bottom of Perc. 15 Min./Inch Perc.'Hole Diameter:: 6" .. Hole Test Run Between" 4 FL and 5 FL .. Comments: Percolation Cavity Presoaked Pri(~r tO Testing. ' Performed By: 'A. Harala. I, ' ' Cedify' That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 1/20/00 ~'~' ".. '-.'-,..' 'L-~ -' '.'v  Municipali~ of ~chorage · ..... ~. Depa~ment of Health & Human Se~ices ~~,~ 825 L Street, ~omge, AK 99502~650 . ¢. ~ ~ ~,ICH~L E. ~lg~aSC:l j SOILS LOG - PERCO~TION TEST ~ ~". CE - 4381 '~, ~;-. . ..'~>-;- . edo~ For: B,ob Klein '; Date Pedo~e~ ~ L~al Description: Lot 12~ Autumn Ridae_ Subdivision j SLOPE S~E P~N "5 : 9 ' 10 ¸.SM I i 'Was Groundwater · Encountered? If Yes, What Depth. Depth. to Water Aftbr Monitoring · Date: No None 1/22/00 's! 'L O P E 13 14 16 17 18 19 Fine Graded' Dense · B~ttom of Hole Reading Date Gross Net : Depth.To Net' Time Time Water · Drop · 1 -9-Dec 1:07 3,12". 2 1:37 30 4,12' ' 1' 3 1:38 3.06" 4 2:08 30 3.94' ,88'. 5 2:38 3.06" 6 ' 3:08 30 '4' · .94' ' Perc. 35 MJn~/Inch · · Perc. HoI(~ DiameterJ 6"' Test Run Between 4 Ft. and 5 Fl. '" comments: Percolation Cavity Presoaked Prior to Testing· -. ' '. Performe~l By: A._lJAca[~ I, }Z~ Cedify That'This Test Was Performed In Accordance With Ail State and Municipal Guidelines In Effect On This Date: 1/20/00 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 12, AUTUMN RIDGE SUBDIVISION GENERAL: The scope of this project includes the the procurement and placement of a new 2,000 gallon septic tank at the location shown on the site plan and the construction of a 75' long by 3' wide by 10' effective depth absorption trench also shown on the Site Plan. The total depth of the trench will be 12' below existing ground and the distribution pipe will be placed at 2' below the surface. All components of the absorption trensh must be constructed a minimum of 100' from the well on this and all adjacent lots. A minimum of 4' of fill must be placed atop the septic tank and 3' of fill atop the absorption trench. In lieu of fill 2" of direct bury insulation may be placed with 2' of fill atop the insulation. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. o Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. The 2,000 gallon septic tank must be procured from an approved septic tank manufacturer and installed at the location shown. o A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. Lot 12, Autumn Ridge July 23, 2002 Page 2 of 2 o A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. A silt barrier or geotextile fabdc must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The podion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield reck for a 5' wide trench. Contractor shall vedfy this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Lot 12, Autumn Ridge July 23, 2002 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve, INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-bdilt of the completed system. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) July 30, 2002 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 12, Autumn Ridge Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: We hereby apply for a lot line waiver to allow the alternate absorption trench on Lot 10, Autumn Ridge Subdivision to be constructed within 5' of the existing lot lines. The owner of the property intends to construct a six-bedroom home on the lot which will require a 75' long absorption trench. The lot is only 90' wide in the area of the proposed alternate absorption site. Soils encountered in the area are silty sands and gravel with percolation rates between 15 and 30 minutes per inch. This material is effective in the treatment of septic effluent and migration should be contained in a fairly limited area. Since the area to the south will never be developed no conflict will ever exist. We therefore recommend the lot line waiver be approved. Michael E. Anderson, P.E. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. l~ox 196650 Anchorage, AK 99519-6650 wv~v.ci.anchorage.ak.us (907) 343-7904 Waiver Review Worksheet WRg: WR030024 Date Received: 4/7/03 Legal Description: Auf~umq Ridoe Lot 12 Engineer: Michael E, Andemoq, PE Anderson Enalneerlna Applicant: Crown Pointe. Inc. PID#: 015,.o -15 HA~: HA030t21 Permitg: Waiver Requested: 4 feet from ab$omtlon field to nrooertv line Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: List Conditions or Reasons for above: Date: L~ .. ~-- 0 ~' By:~ Rec~: :~3417 Amount: $150.00 Date Paid: 4/7103 -'ANDERSON ENGINEERING P.O. BOx'240773 : ANCHORAGE, AK 99524' 522,7773 522'6779 (FAX) April 4, 2003 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 12, Autumn Ridge Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The absorption trench recently constructed on Lot 12, Autumn Ridge Subdivision was inadvertently placed within 4' of the west lot line. The line was not clearly marked dudng construction making accurate placement of the absorption trench difficult. Sufficient area exists on the property to the west for placement of an original and replacement absorption system. In addition, soils in the area consist of silty sand and gravel and absorb water at rates considered good for absorption of septic effluent. No conflicts will exist with the well to be placed on the well to the west. All required separation distances can be met between the new trench and all wells in the area. We therefore recommend a waiver be issued allowing the new trench to be located 4' from the south property line. Sincerely, Michael E. Anderson, P.E. Municipality of Anchorage.. Development SerVices Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 ~wvw.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-054-15 GENERAL INFORMATION Complete legal description Lot 12, Autumn Ridq~ Subdivision LocatiOn (site address or directions) ZiemlakCircle Expiration Date: T/l! Current Properly owner(s) Crown P, ointe, lnc. Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: Six {6) Day phone 727.8167 5400 Abbott Road Anchoracje. AK 99507 Day phone Day phone ,'FYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class ~ Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding tank [] [] Community On-site [--I [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Cedificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Cedificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for propedies served by Class A or B wells or a public water system, The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER o As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineerin.q Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. Phone 522.7773 Date 4~4~2003 ,.. bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory (R=v. 12~0) Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: 'Development Services Department · ' Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 3437904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: A, WELL OATA Well type Pdvate Date completed 9/1 !/2002 Total de)th ..6~ ;ft. Parcel ID: 015-054-15 Lot 12, Autumn Ridge Subdivision ff A, B, or C provide PWSID # Sanitary seal (Y/N)~_ Cased to ,~i% q. FROM WELL LOG Date of test 9/11/2002 Static water level 46 Well production t5 WATER SAMPLE RESULTS: Coliform 0 coloniesJl00 mi. Date of sample: 4/2/2003 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size .2~000 gal. Foundation deanout (Y/N).Y_ Date of pumping C. ABSORPTION FIELD DATA Date installed 8/912002 Length ~ Total depth 1~4 ff. Date of adequacy test Well Log (Y/N) Y Wires pmpady protected (Y/N) y Casing height (above ground) >24 AT INSPECTION ft. g.p.m. in. g.p.m. Nitrate~.~mg.A. Collected by: UFA Number of Compartments _2 Depression over tank (Y/N) N_ Pumper New Construction Date installed 8~U2002 Cleanouts (Y/N) Y High water alarm (Y/N) N 0 colonies/100 mi. Soil rating (g.p.d./ft~ or ~/bdrm) .6 GPD/SF System type Deep Trench It. Width 3 fl. Gravel below pipe 10 Eft. absorption area 1,54.0 ~ Monitoring tube Y_. Depression over field N_ Results (Pass/Fail) __ Fluid depth in absorption field before test in. Water added gal. Elapsed Time: ~ mtn. Final fluid depth in. Absorption rate >= Any rejuvenation, treatment (past 12 mo.) (Y/N & type) N For bedrooms New depth in. If yes, give date g.p.d. D. LIFT STATION Date installed "Pump on" level at ~ in. Datum E. SEPARATION DISTANCES Size in gallons "Pump ofT' level at ~ Cycles tested Manhole/Access (Y/N) in. High water alarm level at in. Meets alarm & circuit requirements? ~ SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main NIA Sewer/septic service line SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout N/A Holding tank N/A Absorption field >5' Surface water >100' Water main >10' Driveway, pa~Jng~ehicle storage >25' Properly line 4~ Water Service line >t0' Curtain drain None Noted F. COMMENTS "See Lol line Waiver Building foundation >l~ Surface water >I01)' Wells on adjacent lots >100' ENGINEER'S cERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with.MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson~ P.E. Date 4/,I/2003 HAA Fee $. Date of Payment Receipt Number (Rev. 12/00) Waiver Fee $ Date of Payment Receipt Number