HomeMy WebLinkAboutLAKEWOOD HILLS #2 LT 20A-2Lakewood Hills #2 Lot 20A-2 #015-134-97 Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: S D / D I.i I PID Number: 015-134-20 Name: MIKE SHARROCK Wastewater System: ❑ New ■ Upgrode Address: 10001 HILLSIDE DRIVE ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: (907) 346-4442 No. of Bedrooms: 6 ■ Deep Trench a Shallow french f] Bed 0 Mound OOther LEGAL DESCRIPTION Sat+ Rating: 0.8 Ft. Total Depth Nor„ o.:s.wl shear 10.83 MAX Ft. CPO/Sq. Lot: Block: Subdivision: Depth to p« Wit" Iron 069or0l swan: Goal Depth be th ppe: 20A — LAKEWOOD HILLS #2 1.6 MAX Ft. 9.2 Ft. Township: - Range: - Section: - So oddee etw« en9'"al shone: Gaal Iargth. 65' SEE DRAWING n. Ft. Dora width: Nvntwh of war owtonc. atwea" ww: WELL: ❑ New ■ Upgrade 2.5 Ft. 1 — Ft. clawhcatwn (pt., A6.c): fatal Depth: co«a To: Total obw vptbn a«: P.pe ^Mena° ASTM D -3034/F-810 PRIVATE 400 rt 282 n. 1196 so.1t.1 onar: Dote Draw: st.lKwatH Leal: Imtow: CATS EYE Data Iwtaad: 9/29/99 M -W DRILLING 8 13 99 250 n. Ywld:Pamp Set /4: Ga,.rd: Cow+q ho9ht "'a"' TAN K 2-3 cpu UNKNOWN n. 18"+ n. SEPARATION DISTANCES ■Septic 0Holding 0 S.T.E.P. To Septic Absorption Lift Holdingblit/pivot. Nohwtoctuhe: ANCHORAGE TANK Capacity in We"*: 2000 From Tank Field Station Tank S.«r Lias Well 100'+ too'+ - - 25'+ wt.na: STEEL N, e. a eo"go w"tw. 2 Surface too'+ too'+ - - - LIFT STATION Water Lot— &?a in pollens: leol«IIYa:w Line 5'+ 10'+ — — P awp en level at: vmp al ,tph wata atan ot: Foundation s'+ 10'+ — — — Curtainpvnp lbws ENctnca khpectanw palam.d hr: Drain NONE KNOWN BENCH MARK Remarks: L«atwn eM Dewcnptwn: TOP OF STAIRS ON DECK = 140.62 TH#1 & TH Q2 DRY ON 9/23/99 TO 16' & 17'. BOTTOM OF SEPTIC TANK = 127.94 MwmaA ENvolion: OLD WELL WAS ABANDONED 8Y M&W DRILLING. Ft' ENGINEERS 111 A OLD SEPTIC TANK WAS ABANDONED PER UPC (PER CATS—EYE). 000600 000 .. Inspections performed by: AWWC, INC. Dates: 1st 9/23/99 ....... .. ............ 2nd 9/24/99 Q Q 3rd 9/27/99 '. J f y Ga ss; 0 Department of Health and Human Services approval �4a� J! 7x53 Dater 04p°prones'*1*°^°oma Reviewed and approved by: 040poo�a n-els R«. 9/91) Nos 25 ALASKA WATER & WASTEWATEH CONSULTANTS, INC. May 16, 2001 Municipality of Anchorage Development Services Department On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Subject: Septic System Documentation for Lakewood Hills #2, L20A To whom it may concern: AWWC, Inc. was retained by the property owners in1998 to design a septic system for a proposed triplex on the subject lot. A design package was submitted to ADEC (copy of the site plan and soils logs are attached), however, approval to construct was withheld until issues were resolved with the water well and a requested waiver. AWWC, Inc. applied for, and received approval to construct a new class C well on the property (See the attached ADEC letter dated 2/26/99). It is our assertion that DEC engineer, Steve Pettis, then gave us verbal approval to proceed with the installation of the septic system. We have discussed this issue with Lindy Benabdelhak (269-7517) at ADEC, who then discussed it with Kevin Kleweno, P.E.. Given the confusion, and missing paperwork (specifically the certificate to construct the septic system) Mr. Kleweno requested only that we submit a copy of the as -built drawings to his department. The property was never converted to a triplex and is currently being sold. Based upon the information provided (well log, septic system as -built drawings, water samples, HAA paperwork), we are requesting that you issue an MOA health authority approval for the subject property as a six (6) bedroom single family dwelling. If you have any questipns, please contact me at 337-6179. .E., M.S. C.C. ADEC, Kevin Kleweno, P.E. 6901 Debatr Road, Suite 2-B • Anchorage, Alaska 99504 Ph: (907) 337-6179' Fax: (907) 338-3246 • Website: akwwc.com 301SI�IH iN3YOSY3 1�40ckl3 0 TH12 ALASKA WATER AND WASTEWATER CONS C. 6901 DEBARR ROAD. SURE 2B. ANCHORAGE, AK. 99 c PHONE: (907) 337-6179/FAX: (907) 338-324 LE OESCRIPAON: ' LAKEWOOD HILLS SUBDIVISION /2. LOT 20A • TY OF WORIQ , ....... . .......... DESIGN OF SEPTIC SYSTEM UPGRADE .... .... PI r FOR: , ' , PHONE - NBE7tol a rey or e . JOHN E. RYAN C/0 PAT SHARROCK 27 5985 QQ , '• 953 • `o DRAWN BY: PAGE: '. •'•••••••• f'co ir 11/20/98,, A.C.G.. 1 100' 2 0F dProffs oOc v W W 0 J J no \ oosTrw 9 I BEDROOM \ SWE-fANIY D6'E1DND NOTE OLD WELL \ — �•' �•+ DONEO II �TH11 „y2 • �TES'T NOUS I DREDM V. ALASKA WATER & WASTEWATER SCALF- C.J.G. CONSULTAN6901 DEBARK ROAD. WTF 29 • ANCHORAGE. Am 99506 SA41rE 907)337!179 • FAX 9071336-3246 1" = 50' REPARED FOR: PHONE NUMBER: PAGE NUMBER: MIKE SHARROCK (907) 244-5085 2 OF 3 EGAL OESCRIPDON: LAKEWOOD HILLS SUBDIVISION #2; LOT 20A, YPE OF WORK AS -BUILT DRAWING OF SEPTIC SYSTEM AND WELL UPGRADE Comess: OCT SQL ... '• ec4v WAS ARAN BY NkW ON 8/90 i F120.5123.4 I n+! 1TH 2 tt C01 18.1 81.0 MTl 12.4 57.8 CO2 82.7 9.3 MT2 58.1 1 8.0 A 8 C01 225.3 242.2 MTl 224.2 241.4 M7 77l (1 7lA 9 II �TH11 „y2 • �TES'T NOUS I DREDM V. ALASKA WATER & WASTEWATER SCALF- C.J.G. CONSULTAN6901 DEBARK ROAD. WTF 29 • ANCHORAGE. Am 99506 SA41rE 907)337!179 • FAX 9071336-3246 1" = 50' REPARED FOR: PHONE NUMBER: PAGE NUMBER: MIKE SHARROCK (907) 244-5085 2 OF 3 EGAL OESCRIPDON: LAKEWOOD HILLS SUBDIVISION #2; LOT 20A, YPE OF WORK AS -BUILT DRAWING OF SEPTIC SYSTEM AND WELL UPGRADE Comess: OCT SQL ... '• ec4v PERMIT NUMBER: AS -BUILT DRAWING PARCEL NUMBER: FINAL GRADE 138.2 - 137.5 5t1 512 TOP OF TANK TOP OF TANK ® OUTLET- 132.79' INLET— 132.83' INVERT OF BUNG INLET— 132.31' NSW 2000 6&LON I I %P,nC TANK INVERT OF BUNG OUTLET- 132.04' 80TTOM OFA TRENCH a 89.25 ALASKA WATER & WASTL'WATER CONSULTANTS, INC. 6901 DFRARR ROAD. SUITF 28 • ANCMORAGF. M 99SM • PN F (907)337.609 • FAX (907)338-371 PREPARED FOR: PHONE NUMBER: MIKE SHARROCK (907) 244-5085 LEGAL DESCRIPTION: LAKEWOOD HILLS SUBDIVISION y2; LOT 20A, TYPE OF WORK: PROFILE AS—BUILT OF SEPTIC SYSTEM UPGRADE FINAL GRADE 102.8 (AVG.) ORIGINAL GRADE 100.04-100.98 INVERT OF PIPE 98.45 MAX TOTAL DEPTH BELOW O.G. - 10.83 '10/2001 o pr ....... -N% ............ BY: C.J.G. QQQ NUMBER: 3 OF 3 '•, f e Gorness. 0o 7953 NJI 03/23/1999 12:00 3453287 M W DRILLING, INC PAGE 01 - M•W DRILUNG, Ino. ' P.O. a" 110676 a 1*"0 OW aawd mve av (907) s4HM ANCHOPAOL ALASKA 09011 a�143-F:1:17aTel, Location (address of: Township, Range, Section, if known; or distance main road rnr Jnh. r.kXr wnnn HIr.T.4y/n� M9• 1nnn1 urr.v.cn TF. no ANCHORAGE. ,A,)5,,, -- Sias of casing . -6 u Depth of Hota 5 D 0 feet Cued to 2 B 2 fsu Btatk: water W& a a0 k• tbelow) land surface. Finish of well (check one) open end ( ); screen ( ): Perforated ( X ). SVA. Well pumping test ate. itnl.a pe} ftW* (mtnute) for -1 --hours w1t1:.100% ft of drawdown from static lavel. DateofcompleNlon 13 AUG139T 1929_ WILL too Depth in feet from ground surface Give drtalla of formations perutraW. size of material, color and hardness 0 TO 2 2 TO 32 3_ 'ATO 42 42 TO tie 4 134 To 196 196 232 232 201 ,ip 261 To 270 27UTO 28v 230 Tp 36i ,nn5 To 3b7 367 TO 400 TO TO .MEDIUM GRAVEL: SILTY SAND: SILTY GRAVELt BROWN, SILTY GRAVEL: SANDYf WET, 3 GPM CLAYt SILTY BEDROCK: GREEN WITH WHITE LENSES, GNALL WATER a'EAPS I• SPORADIC FRACTURES UoI=CONTRACTOR puaLf� '/61 s v M R m Cc TF 1 DEPT. OF ENVIRONMENTAL CONSERVATION DIVISION OF ENVIRONMENTAL HEALTH DRINKING WATER and WASTEWATER PROGRAM 555 CORDOVA STREET ANCHORAGE, AK 99501 http://www.state.ak.us/dec/home/htm December 14, 1998 ;1 1 TONYKNOWLES, GOVERNOR Telephone: (907) 269-7521 Fax: (907) 269-7650 Jeffrey A. Gamess, P.E. Alaska Water & Wastewater Consultants, Inc. 7320 East Chester Heights Circle Anchorage, Alaska 99504 Subject: Lot 20A, Lakewood Hills Subdivision #2, Anchorage, Alaska, Septic System Upgrade to Multi -Family Use, ADEC Project Number 429, Domestic Wastewater Plan Review. Dear Mr. Gamess: This letter is in response to your submittal received in this office on December 7, 1998 requesting construction approval for a replacement septic system on the above -referenced property. The domestic wastewater disposal system is proposed to serve a 6 bedroom, single family dwelling that would be converted to a multi -family dwelling in the future. Your request to approve the wastewater disposal system for multi -family use would require waiving the 75 foot separation distance between the existing private well and the replacement sewer service line. Since 1985, this Department has delegated plan review authority to the Municipality of Anchorage for single family drinking water and wastewater systems. The Department is requiring submittal of plans to upgrade the entire property to a multi -family dwelling before the Department will consider the required separation distance waiver. Attached is a checklist of submittal items required for a Class C Public Water System plan review. State regulations have been modified to require fees for plan reviews and waiver requests. The fee required for this project is $200 for the drinking water system review, and $230 for the separation distance waiver review. These fees are in addition to the $295 already submitted for the domestic wastewater plan review. Jeffrey A. Garness, P.E. -2- December 14,1998 Thank you for your cooperation with this Department. If you have any questions, please contact me. Sincerely, Steven A. Pettis Env. Eng. Asst. II cc: Jim Cross, P.E., MOA/DHHS, w/o end m - \V -----;/1\ F I I A y I\ \ wR9.0 Rmw. R]UWW� Gfµ-0I11. DKMC w C�pICT[ / W al \ �o -- �P'� TQf Naa nRrowcR I r oncocRr r rinr.9., r[. PRoposm }IIDem J u• umI w I", 0DR h+x) W 9A• wo[ wIH IF a RE,w.XEWDR DIV I91aIm NOTE: PRIOR TO DRILLING THE NEW WELL THE DRILL •• ER e• I VERIFY TKAT THERE ME NO SEPTIC SNSTENS WITHIN 130 FEET OF THE PROPOSEp WELL LOCATION. NO YOB OR ADEC RECORDS COULD BE FOUND FOR THE SEPTIC SYSTEM ON THE IAT TO THE NORTH. I 9n I. 1) M WNwM011 9W11 Nw[ M 9/SI �� LK MOM 190' RRL L1RM.1011 wwR m•W�611RKIIpi� 9) M RIRIfN t m r w9i.1R{p ►IA49A. m M kan9 TanaRn ALASKA WATER AND WASTF.W rn1TTCTTTTAPTTc TTT!` iffA mne TNaf 4 CRIbN D—�I/ITN ioa RPM TMOIC eD1RI m USE M wits A ALASKA READING WATER & WASTEWATER CONSULTANTS, INC. F DRY 10/30/98 7320 E. CHESTER HTS. gRC1E •ANCHORAGE. AK. 99504 P.`�, •• ,900 (INCHES) 11/2/98 PERC. H PHONE ( 7) 337-6179 •FAX (907) J36 -J246 ,�X�0 O 1 SOIL LOG — PERCOLATION TEST 6• — 2 3:47 30 + :: 4 3/4• LEGAL DESCRIPTION: LAKEWOOD HILLS SUBDIVISION /2. LOT 20A. ••••• • ' ' .• •••• '"".•... PERFORMED 4 FOR: JOHNNY RYAN ......• J f A. UO e88 DATE PERFORMED: 10/30/98 Q(�A E-7953 OEM rest — TEST HOLE #1] .,� •p............ –4=4�-- -- 30 7= 4 1/2• ==_= --- ORG/LOAM °r...w� 2 SOIL CLdSSIFICATIONS • #i# GW Z.'. _ :: DRG - 3 ;iI !t • .. GP I MLw 0 EXISTIN C61 w GM SW MH 5-' SM •''•" SP CH \ r #! SILTY SAND W/ 1 + SM OH \ LIGHT GRAVEL SC 7 DEPTH TO' DATE GROUNDWATER THO } } I2 i 9 } {!1• SITE TH/2� — �} 00 10 ; kilt r _ 11 ., , . �0 ,. '' • 'LIE ' IS TIES 12 13 '' ' '' ....• : ;: . ;t; SP 14 '' • '' ::•: •• 15 '••' .... �. ..•.•. B.O.N. 17 ie 19 PERCOLATION RATE 6.7 (MINJINCH) PERC. HOLE.DIA. 6 (INCHES) 20' TEST RUN BETWEEN 5.5 FT. AND 6.0 FT. COMMENTS:PERFOMED'BY ALASKA WATER do WASTEWATER I, CERTIFY THAT THIS •WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS - DATE. DATE: DATE READING WATER LEVEL DRY 10/30/98 -' 15 11/6/98 DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 11/2/98 PERC. H WAS PR ED 5 HOU PRIOR TO NG 1 3:17 — 6• — 2 3:47 30 1 1/4• 4 3/4• 3 3:47 — 6' — 4 4:17 30 1 1/2' 4 1/2• 5 4:17 — 6• — – - 6--- –4=4�-- -- 30 1 1�2� 4 1/2• A'LASSA WATER & WASTEWATER CONSULTANTS INC. J20 p{EST�A dRd.E ' ANCHORAGE AX. 99504 P O� PHONE (907) 35%l79 • FAX (907 Jia -3246 SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: LAKEWOOD HILLS SUBDIVISION J2. LOT 20A ••• •••• ..•. PERFORMED FOR: JOHN E. RYAN ••• • •• • •• ••• •••••• A. Go sa; DATE PERFORMED: 10/30/98 e ey & !y C Go ` gt _ __ TEST HOLE #2 •^,''' _--- pyo ORG/LOAM 2—i • SOIL CLASSIFICATIONS Q : o GW r _ : ORG \ 3 + GP IML Q ExisnN c hilU GM CL �• u 4 : GC OL SW MH SP CH • SILTY SAND W/ S1 ' OH / 8 LIGHT GRAVEL SC I 7 TH# I 8 , i TH/2+ / 9 ! SITE PIAN L — t 1• ' 1 ' 10 . I •1 11 • • ,• 12 13 •'•'• SP 14 ...• 15 •' •••• 17 B.O.H. 18 19 PERCOLATION RATE N/A (MINJINCH) PERC. HOLE DIA. 8 (INCHES) 20 TEST RUN BETWEEN N/A FT. AND N/A FT. COMMENTS: WEST TEST HOLE PERFOMED BY ALASKA WATER do WASTEWATER I, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: DEPTH TO DATE GROUNDWATER DRY DATE READING _ ----fig'—y.— 10/30_/98 11/8/98 WATER LEVEL READING NET DROP (INCHES) DATE READING CLOCK TIME �T TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) _ E._TEST PERCO _HOLE�1 TION DA FOR j' • 'I Municipality of Anchorage On -Site Water and Wastewater Program ``- (907)343-7904 Certificate of On -Site Systems Approval Parcel I.D. 015-134-97 Expiration Date: 1. GENERAL INFORMATION Complete legal description Lakewood Hills #2; Lot 20A-2 Location (site address) 10001 Hillside Drive *Anchorage 99516 Current Property owner(s) Marcia Templin Mailing address Real Estate Agent 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 nX 4. TYPE OF WATER SUPPLY: ❑ Individual Well ❑ Individual Water Storage ❑ Community Class _ Well ❑ Public Water System ❑ WaiverNariance request for: N/A Day phone 632-2317 Day phone TYPE OF WASTEWATER DISPOSAL: Individual nX Holding Tank ❑ Community ❑ Public Sewer ❑ Received by: COSA to be releas d to the engine4, u ess otherwise requested by the engineer. COSA Fee $ 25 z -1O Date of Payment 3 —04C., Receipt Number Qq 12 L G COSA # d Sc I tog Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Garness Engineering Group, Ltd. (GEG) Phone (907) 337-6179 Address 3701 E. Tudor Road, Suite 101, Anchorage AK 99507-1259 Engineer's Printed Name Jeffrey A. Garness Date ! �7, �l � In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend on a variety of variables including, but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the systems; therefore, GEG makes no warranty (express or implied) regarding the future performance ofthe well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail. The content of this report is for the sole benefit of the person/party who retained GEG. Reliance upon the information provided in this report by any other person or party, including but not limited to subsequent property purchasers, is not authorized. In short, GEG disavows any legal duty to anyone other than the person/party who paid for this report. 6. DSD SIGNATURE System #1 Approved for `J bedrooms System #2 Approved for Disapproved Conditional approval for M bedrooms bedrooms, with the OFgNC ., j� ON-SITE WATER AND m WASTEWATER Cl) g ipu[?O ;RAM mac: 10., O� Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 9.1-12Aoc If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: LAKEWOOD HILLS #2; L20A-2 Parcel ID: 015-134-97 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 8/13/99 Sanitary seal (Y/N) YES Total depth 400 ft. Cased to 282 ft. FROM WELL LOG Date of test 8/13/99 Static water level 250 ft. Well Log (YM) YES Wires properly protected (Y/N) YES Casing height (above ground) 18+ in. AT INSPECTION 3/2/16 221.3 ft. Well production 2-3 g,p,m. 1.7+ g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 7.01 mg./L. Collected by: GEG. Ltd, Arsenic: NO ug./L. Date of sample: 3/16 B. SEPTIC/HOLDING TANK DATA 'PER 2001 HAA FCO IS LOCATED IN GARAGE (SEE ATTACHED PHOTO) Tank Type/Material SEPTIC/STEEL Date installed 9/23-27/99 Tank size 2000 gal. Number of Compartments 2 Foundation cleanout (Y/N) *1 ESES Depression over tank (Y/N) NO Cleanouts (Y/N) YES High water alarm (YIN) N/A Date of pumping 3/3/2016 Pumper NORTHLAND PUMPING C. ABSORPTION FIELD DATA *6ELow ExIs11NG GRAD Date installed 9/29/99 Soil rating (g.p.d./feo /bd 0_8 System type DEEP TRENCH Length 65 ft. Width 2.5 ft. Gravel below pipe 9.2 ft. Total depth *13.6+ ft. Eff. absorption area 1 196 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 3/2/16 Results (Pass/Fail) PASS For 5 bedrooms Fluid depth in absorption field before test 14 in. Water added 832 gal New depth 19 in. Elapsed Time: 120 min. Final fluid depth144 in. Absorption rate >= 750+ g,p.d, Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date — 2000+ GALLON PRE—SOAK WAS PERFORMED ON 3/1/16 SEE ATTACHED PHOTO SHOWING SETTING OF TESTHOLE NEAR THE DRAINIELD SEE ATTACHED EMAIL REGARDING SOIL COVER OVER DRAINFIELD D. LIFT STATION Date installed Size in gallons Manhole/Access "Pump on" level at in. "Pump ofr E. SEPARATION DISTANCES water alarm level at in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ Public sewer main 75'+ Sewer /septic service line 25'+ Animal containment areas 50'+ On adjacent lots 100'+ Public sewer manhole/cleanout 100'+ Holding tank Manurelanimal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water, 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehide storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS SEPTIC TANK IS LOCATED UNDER DRIVEWAY; IT DOES NOT APPEAR TO BE PART OF THE MAIN DRIVEWAY AND IS ASSUMED TO BE A "PULL OUT" SECTION; IT IS NOT RECOMMEND TO DRIVE OR PARK OVER THE SEPTIC TANK G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are In conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 317-4/G (Rev. 11/05) Municipality of Anchorage o pGE sG, Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # OSC161084 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 20A-2 of Lakewood Hills #2 subdivision. This inspection revealed a nitrate concentration of 7.01 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. David Garness From: 'Marcla Templin <marcia.templin@gmail.com> Sent: Friday, March 18, 2016 11:37 AM To: David Garness Subject: Re: Lakewood Hills #2; Lot 20-2A David, We have lived in the home at 10001 Hillside Drive (Lakewood Hills #2; Lot 20-20A) since 2001. We never experienced any freezing problems with the septic system - it performed flawlessly. Regards, Marcia Templin On Fri, Mar 18, 2016 at 11:30 AM, David Gayness <David(a�garnesseneineerine.com> wrote: Marcia, The MOA issued a comment sheet regarding the COSA for the subject property. As we talked about previously there was a deficiency regarding settling of the testhole near your drainfield. Per conversation with Tim at the MOA on-site department on 3/18/2016, we need an email or letter from you stating that you have not received any freezing problems. In short, if you would please respond to this email stating that you have not had any freezing problems with your septic system, the MOA will approve your COSA. If you would please give me a call if you have any questions, thank you. David J. Garness, EIT Consultant Garness Engineering Group, Ltd. 3701 E Tudor Road, Suite 101 Anchorage, Alaska 99507 Phone: 907-337-6179 Fax: 907-338-3246 Website: www.gamessengineering.com i 1 Lot 4 1 I / I 20' UTILITY EASEMENT i / N 89'56'00"E 280.15' z 10.1'02.1' SHED rn — DECK RAOIUS V { PROTECTIVE 3.0'x13.3° CANT ASPHALT WELL DRIVEWAY 8.0'02.0'I GREENHOU`. tib N I \ 1.2' CANTS as^ 2 STORY RESIDENCE w/ re FULL BSMT. \ '.,� RETAINING S 9'56100"W 90.0 '' j WALLS I I tiR X PORCH''.' CONCRETE ,: GRAVEL• PATIO DivEWAv i = I F— i SEPTIC PIPES ' r I U) I z I I Lot 20A-1 m 1 ( v 1 0 ;0 I I m I I ,LA� co ... N 4456'00"E 21.21' I 1 I N 45'04'00"W 21 21' SEPTIC PIPES Z Lot 20A-2 0 a 1.82 Acres I I I 0 I I I I I I o I -1---------------- "W I t I S 89.50'21 99.82' f I I 1 � Lot 21 A PLOT PLAN _ AS BUILT X SCALE 1" - 50' GRID SW 2540 Project No. 16-060/AII Lot 5 Lot 1 6.2'x16.2' SHOP Lot 2 T&E EASEMENT Lang & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 49515-3049 (907) 522-6476 Phone Registered Land Surveyors (907) 522-4625 voxes' F A��aq kenOlangsurvey.com / jonathanOlangsurvey.com I hereby certify that I have surveyed the following described props�Q •. S��oo LOT 20A-2, LAKEWOOD HILLS #2 (PLAT 2001-93)j Anchorage Recording District, Alaska. and that the Improvements situated thereonare ........ .:.... within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, fronamisalon lines o- 3ther visibler KENN G. ... easements on said property except as indicated hereon.Qr 41. Imo; Dated this the VD S 520 Day of h1pRrv� 2��,:•_, at Anchorage, Alaska i• �•' It is the responsibility of the owner to determine the existence oz any easements, a0 �� L covenants, or restrictions which do not appear on the recorded subdivision plat. Lot 3 MONUMENTATION N 89°56'00'E M2 50.00' (R a M) pNOYt 3NlJb NETTLETON p SUBD. J i I B/OINT UNSUBDiVIDED 12N4R3W � Q�fSt4 61 4 I M1 I N ss°56'00'E 280.00' (R) M5 SEE NE CORNER DETAIL A. 513 �oO\� iV .. N 69156'00'E 280.15' (M) — — _ �f4tt992S �D N p CEN k 10 H/B INT s/A JO 1N 1 FOUND 2 1/2' BRASS FOUND 2 1/2' BRASS N 20' UTILITY EASEMENTS Q� CAP MON 30 FEET CAP MON. 1.0 FOOT I ?' BELOW GRADE IN BELOW GRADE IN 0 S I I MON. CASE a MON. CASE I < 1 N �9°56'00' ZOA�2 Lot i M3 M4• v 79.149 s.t. dd m 1 saaoM3 S9S° 1.817 AcresOOD yEWOOD(2? 1 m �19 U) I v' I z i •`'�`^ 20A-2 2OA-2 I W 8. $$ 1 w92DA-1l 2OA� 1 08 89 I N MSI. O� 83 Z 5202-5 5202-S f f 20A-- t 8 0; ^`" 2001 2001 N '-� tp V s --I I ON NN I 67.355 s.t. io na a� 2 1/2' ALUM. CAP ON 2 1/2' ALUM. CAP ON J 1 W o g o 1 1.551 Acres - g g 80 Lor 2 Z 2 1 /2' x 30' ALUM. PIPE 2 1 /2' x 30' ALUM. PIPE _ r.i �^ z Q SET FLUSH WITH GROUND SET FLUSH WITH GROUND Z S 44°56'00'W 1 I � 1 2121' I o Q 1451- YELL" MAMC C" Z. 1 8B I G3°'I I S 4z0.24'C,O"E 1 �— — ODONL � a'W � 1 u, _ y Z REF 10 Q I 3 I z = MON NW K® L Q 1 1 $ i Coft Let 3 q 9�j �q B/B INT m FOUND I' STEEL PIN sG 1'085S 6 -s a60 "J (j V" I 50.00' 180.00 99.82') ��' MON � SLT AT ALL CORKM NOT 0�—RECOIST w I S 89°50'2t'W 279.82' (M) FOUND 3' BRASS CAP MON. OTHUTWME S 89°58'00'W ZBO.00' (R) I 10' TELECCMMUNICAMON FLUSH WITH GROUND ocscRM Gate ENT 1 8A Q FOUND I' STEEL PW 1 (DEDICATEDND ELECTRICAL BY THIS PLAT) off: /3 M I I I SEE SW LOT CORNER DETAIL Ti*ne_.__ J .�— � UNSUBDIVIDED Requ¢¢ted ByLot 21A M2 1) ACCESS 15 LIMITED ON HILLSIDE DRIVE TO A COMMON DRNEWAY FOR LOTS 2OA-I AND 2OA-2. 2) THE EXISTING SEPTIC SYSTEM ON LOT 20A-2 FALLS WITHIN THE 10' TELECOMMUNICATION 8 ELECTRICAL EASEMENT DEDICATED BY THIS PLAT ALONG THE EAST BOUNDARY AND IS NOT CONSIDERED AN ENCROACHMENT. REPLACEMENT OF THIS SEPTIC SYSTEM WITHIN THE EASEMENT IS NOT ALLOWED. 'S CERTIFI LEGEND ® - MONUMENT (SEE MONUMENTATION) 01, OTHER MONUMENTATION (AS DESCRIBED) (R) -RECORD (PER PLAT No. 71-314) (C) COMPUTED (FROM PLAT No. 71-314) (M) MEASURED B/D INT BEARING /DISTANCE INTERSECTION -BEARING / BEARING INTERSECTION X - NOTHING FOUND OR SET 1, Kenneth Lang, Profes!s1!?tjaKand Surveyor, do hereby certify that THIS is a true and correct roprosentation. of lands actually surveyed and that the distances and bearings are shown correctly and that all permanent exterior monuments, all other monuments and tot corners have been set and staked, or if final completion is assured by subdivision agreement, they will be set as specified in sold subdivision agreement. Lot comers set by: N/A Monuments set by: N/A PLAT APPROVAL Plat approved by the Municipal Platting Authority this -'2 -,tL day of TJI-. 20-9 � I. J, Y40L L ui torficial APPROVALS os Platting Officer Munieipcl Surveyor 7 Environmental Protection`f�G 4�`, t Lot 20A -I STEEL PIN FOUND HELD FOR SEARING r— INT , SW CORNER DETAIL NO SCALE TAX CERTIFICATION OF�% All real property taxes levied by the Municipality of Anchorage A (!�� on the area shown on this plat have been paid in full, and if Q : approval is sought between January t and the tax due date, there is on deposit with the chief financial officer an amount sufficient to pay estimated real property tax for the current year. •.XENNE a. A t.ANO,horized Official Date V LS -5202 ACCEPTANCE OF DEDICATION CERTIFICATE OF OWNERSHIP AND DEDICATION I (we), hereby certify that I (we) hold the herein specified property interest In the property described hereon. I (we) hereby dedicate to the Municipality of Anchorage all areas depicted for use as public utility easements, streets, alleys, thoroughfares, parks, end other public areas shown hereon, a slope reservation easement sufficient to contain cut and fill slopes of 1.5 feet horizontal for each 1 foot vertical (1.5 to 1) of cut or fill for the purpose of providing and maintaining lateral support of the eonstruMod streets. Thera to rocervod by the grantors, their hairs, successors and assigns, the right to use such areas at any time upon providing and maintaining other adequate lateral support, as approved by the Municipality. I (we), hereby agree to this plat, and to any restrictions or covenant appearing hereon and any such restriction or eaveng t hall be binding and enforceable against present and succeasi",,owners//,f subd!ded prop�rfy. MICHAEL G SSH'ARROCK DANA L. SHARROCK 10001 HILLSIDE DRIVE 10001 HILLSIDE DRIVE ANCHORAGE, ALASKA 99516 ANCHORAGE, ALASKA 99516 (907) 346-3323 (907) 346-3323 Notary Acknowledgement 9 Notary Acknowledgement for subscribed and \0..........�4L %- ( op ��7r ec:NOTARY16E Y :. PUBLIC.1 FOUND SPRUCE STUMP - o - NOTHING SE( cl _ BY BEARING/BEARING 1 /iEW' ICIARY INTERSECTION 1 Lot I Lot 20A-2 1 Signature HAMPTON MLS PLAT t3 SUBDIVISION NE CORNER DETAIL Scafe: I' • 10' 24 TAX CERTIFICATION OF�% All real property taxes levied by the Municipality of Anchorage A (!�� on the area shown on this plat have been paid in full, and if Q : approval is sought between January t and the tax due date, there is on deposit with the chief financial officer an amount sufficient to pay estimated real property tax for the current year. •.XENNE a. A t.ANO,horized Official Date V LS -5202 ACCEPTANCE OF DEDICATION CERTIFICATE OF OWNERSHIP AND DEDICATION I (we), hereby certify that I (we) hold the herein specified property interest In the property described hereon. I (we) hereby dedicate to the Municipality of Anchorage all areas depicted for use as public utility easements, streets, alleys, thoroughfares, parks, end other public areas shown hereon, a slope reservation easement sufficient to contain cut and fill slopes of 1.5 feet horizontal for each 1 foot vertical (1.5 to 1) of cut or fill for the purpose of providing and maintaining lateral support of the eonstruMod streets. Thera to rocervod by the grantors, their hairs, successors and assigns, the right to use such areas at any time upon providing and maintaining other adequate lateral support, as approved by the Municipality. I (we), hereby agree to this plat, and to any restrictions or covenant appearing hereon and any such restriction or eaveng t hall be binding and enforceable against present and succeasi",,owners//,f subd!ded prop�rfy. MICHAEL G SSH'ARROCK DANA L. SHARROCK 10001 HILLSIDE DRIVE 10001 HILLSIDE DRIVE ANCHORAGE, ALASKA 99516 ANCHORAGE, ALASKA 99516 (907) 346-3323 (907) 346-3323 Notary Acknowledgement 9 Notary Acknowledgement for subscribed and \0..........�4L %- l: sworn to beforeme this _{� day of l+=r• ,, 20 ��7r ec:NOTARY16E Y :. PUBLIC.1 -Ndt//dry P#I116-for the Stafe of Alaska 6(y Commission Expires RIND _ Notary Public for the'Stota•of Alaska FAY Commission Ex. 11 /iEW' ICIARY THiS 1 Signature Title PLAT t3 Ryan' Investments LLC~ 24 1713 Momingt(de Court Anchorage, Alaska 99501 6 The Municipality of Anchorage hereby accepts for public uses and for public purposes the real property dedicated an this plat including, but not limited to the easements, rights-of-way, alleys, roadways, thoroughfares and parks shown hereon. Dated of Anchorage, Alaska this 70' day of Tj7- 2061 G V •Attest: MVctpal Clark „gym Mayor of Anchorage I Vicinity Map Scale: 1" = 1 Mile I 9 Notary Acknowledgement JQ`tiPSHAAri,y//o Q @: je:: '••oma; I 12 __ NOTARY`. for Subscribed andy sworn to before me this ,, day of 20C,/, os '�`• T1iC -Ndt//dry P#I116-for the Stafe of Alaska 6(y Commission Expires RIND _ I Vicinity Map Scale: 1" = 1 Mile I LAKEWOOD HILLS, ADDN. #2 CONTAINING 3,368 Acres A SUBDIVISION OF LOT 20A, LAKEWOOD HILLS #2 (Plat No. 71-314) LOCATED WITHIN THE SW 1/4, SEC 13, T12N, R3W, S.M., ALASKA Lang & Associates, inc. Registered Land Surveyors GRID: 2540 SCALE: 1" = 10 DRAWN: JCL SHEET 1 OF 1 CHECKED: KGL 00%- F3 Anchorage, Alaska 99515 (907) 522-6476 1907) 522-4625 Fax 0' DATE: JUNE 2001 PROJECT #: 00-133 JOB FiLE: K00133FP/FQ.crd, CASE #: S-10645 9 g 10 1 II I 12 I � AB061'r RIND _ I THiS 1 16 15 PLAT t3 24 6 UPPER DVALCY OVAI.E! RWa FRDAt 1 T 12 N 21 22 23 24 z c LAKEWOOD HILLS, ADDN. #2 CONTAINING 3,368 Acres A SUBDIVISION OF LOT 20A, LAKEWOOD HILLS #2 (Plat No. 71-314) LOCATED WITHIN THE SW 1/4, SEC 13, T12N, R3W, S.M., ALASKA Lang & Associates, inc. Registered Land Surveyors GRID: 2540 SCALE: 1" = 10 DRAWN: JCL SHEET 1 OF 1 CHECKED: KGL 00%- F3 Anchorage, Alaska 99515 (907) 522-6476 1907) 522-4625 Fax 0' DATE: JUNE 2001 PROJECT #: 00-133 JOB FiLE: K00133FP/FQ.crd, CASE #: S-10645 Municipality of Anchorage ` Development Services Department Building Safety Division On -Site Water & Wastewater Program . 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 tw CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR -A SINGLE FAMILY DWELLING - Parcel I.D. WELLING'Parcell.D. 015-134-20 HAA# 1-1 OI Ox -r _ 1. GENERAL INFORMATION Expiration Date: 9 - - o0 / Complete legal description' LAKEWOOD HILLS SUBDIVISION #2; LOT 20A Location (site address or directions) 10001 HILLSIDE DRIVE, ANCHORAGE, AK 99516 Current Property owner(s) MIKE SHARROCK Day phone 346-4442 Mailing address 10001 HILLSIDE DRIVE, ANCHORAGE, AK 99516 Lending agencyDay phone Mailing address' Real Estate Agent Day phone Mailing address Unless otherwise requested, HAA will be held by DSD /or pickup. 2. NUMBER OF BEDROOMS: 6 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4.' STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, l verify that my Investigation, based on procedures outlined In the Health AuthorityApproval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of sinicture Indicated herein. I further verify that based onthe Information obtained from the Munldpality ofAnchorage files and from my Investigation inspection,the on-slte water supply and%r wastewater disposal system is(are) in compllance with all applicable Municipal and State codes; ordlnanoes,'and regu/ations in effect at tie time of Installation.. . Name'of Finn; ALASKA, WATER '& :WASTEWATER CONSULTANTS, 'INC. phone .337-6179. AddrassN 6901 DEBARR ROAD,:SURE 26 s ANCHORAGE, AK 99504 Engineer's Printed Name : JEFFREY. A. GARNESS, P.E. Date D1, Engineers Comments:oo�o !non cducting this evaluation, AWKV, Inc. attempted to provide a thorough, - `�, QF 0 44 conscientious engineering anaWs of the system in accordance with ADEC and MOA DSD Guidelines 6 Regulations. :T he reported results desatbed the performance of the system under the oondNons encountered at the time of the test and separatfon D e distances measured to readily Iden tifabis fee tures. The opera tonal life of all wefts and Q septic systems depend on the local soils condition, groundwaterlevals that may DD fluctuate during the year, and the Crater usage of the famlybeing served by the system. V"' : D These conditions are outside the iiontrol ogre evaluator of the System. Satisfactory test OQ e f e _ ass; results do not guarantee future system, ayg dQ of CE -7953 : ep g performance of the tem, nor do N u varitee that u SFO there are no hidden detects or encroachments. AWWC, Ina can thoreforenot provide . • ...... anywarranyorfuture estimate ofhowlongMesystem willowntinuetomeetthe X00°Profess°�o`� operational requirements of the ADEC or MOA DSD. The content orthis report is for the sole benefit of the ownerfisted above. Any reliance upon or use of this report by any other person or paryIs riot authorlred, nor wffl R confer any legal tight whatsoever. 5. DSD SIGNATUREtliNl�tttffff/�i.- Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Manitenance Agreements Supplemental Engineer's Reort Other • ON-SITE WATER AND WASTEWATER : PROGRAM By: 449� 4!)' /a"�r Original Certificate Date: 6-1-01 Vtw.l2=) Municipality of Anchorage • �' Development Services Department Building Safety DMsion Onsite Water 8 Wastewater Program 4700 South Bregaw SL P.O. Box 196650 kichorage, AK 9951944 wwwxLarichorags.ak.us (907)943-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: LAKEWOOD HILLS SUBDIVISION N2: LOT 20A Parcel ID: 015-134-20 A. WELL DATA Well type PATE UA. B, or C provide PWSIDX N A Date completed 8/13/99 Senitaryseal (Y/N) YES Total depth 400 R Cased to 282 fL FROM WELL LOG Date of test 8/13/99 Static water level 250 1L Wen production 2 — 3 g.p.m. WATER SAMPLE RESULTS: Conform 0 colonlesl100 ml. Nitrate 3.74mgJL. Well Lop (Y/N) YES Wires properly protected (YM) YES Casing height (above ground) 18+ in. AT INSPECTION NEW fl g.p.m. Other bacteria _0.00lonlesM00 ml. Date of sample: P-5-18"01 Collected by: AWWC. INC. B. SEPTICIHOL.DING TANK DATA Tank Type/Matertal STEEL Date Umstelled 9/29/99 Tank size 2000 get. Number of Compartments 2 Cteariouts (Y/N) YES Foundation deanout (Y/N)OYES Depreaslon aver tank (Y/N) NO High water alarm (Y/N) N/A Data of pumping 4/17/2001 Pumper ISAAC'S Date installed 9/29/99 Sop reting .p d fe/bdml) O_8 System type TRENCH Length 65 R Width 2.5 R Gravel below pipe 9.2 fL Total depth r � R Eft. absorption area 1196 M Monitoring Vibe `ES Depression over Held N0 Date of adequacy test NEW DRAINFlELD Results (Pass/Fall) For 6 bedrooms 781apsed depth in absorytion field before teat_ UL Water ad -Wow depth _in. Time: uid depth _ Im. Absorption rate m 9.pd. Any re)uvenation treatment (past 12 mo.) (YM d, type) NONE KNOWN If yes. give data — D. UFT STATION Date installed Size in gallons 'Pump on' level at_ in. E. SEPARATION DISTANCES High water alarm level at Cycles Meets alar & circuit requiremerb?_ SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanMIft station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A On adjacent lots 100'+ On adjacent kft 100'+ Public sewer manhole/deanout N/A Sewer /septic service One 25'+ Holding tank N/A SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation 5'+ Property One 5'+ Absorption field 5'+ Water main N/A Water service One 10'+ Surface water 100'+ Wells on adjacent Tots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property One 100+ Building foundation 10'+ Water main_ N/A Water service One 100+ Surface water 100'+ Driveway, parldngNehlde storage 5'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION g,;re Ur I certlly that I hem determined through field inspection and * ' X review of MurUdpat records that the above systems are In ........ . . ............ conformance with MQA HAAguidellnes In effect on this date. e A. Gameaa' Engineer's Printed a JEFFREY A. GARNESS 7953 • �aF Data O�•,�dp......... •.�o HAA Fee S -IL _00 Date of Payment -5 Receipt Number a a� (Rev.12=) Waiver Fee $ Date of Payment Receipt Number 1 •moi mol O f� TONYKNOWLES, GOVERNOR 00 0 0 0 0 p 00 DEPT. OF ENVIRONMENTAL CONSERVATION C . D DIVISION OF ENVIRONMENTAL HEALTH �p DRINKING WATER and WASTEWATER PROGRAM T. I 1---e* (907) 269-7521 555 CORDOVA STREET ANCHORAGE, AK 99501 http://www.state.ak.us/dec/home/htm e el, Fax: (907) 269-7650 February 26, 1999 RECEIVED MAR 1 1999 Mr. Jeffrey A. Garness Municipality of Anchorage Alaska Water &Wastewater Consultants, Inc. Dept. Health & Human Services 7320 East Chester Heights Circle Anchorage, Alaska 99504 Subject: Lot 20A, LakewooSource e Well,Hills Subdivision ADECProject umberr4Alaska; Water Systemstem 429, Construction Approval. Dear Mr. Garness: This letter is in response to your submittal received in this office on February 19, 1999 requesting construction approval for a new Class C Public Water System source well to serve a six bedroom, multi -family dwelling on the above -referenced property. From the submitted information, it appears that the location of the well meets the concerns of this Department regarding separation distances outlined under State Drinking Water Regulations (18 AAC 80.030). Therefore, the Department is granting construction approval of the Class C Public Water System source well in accordance with 18 AAC 80, subject to the following requirements. 1. Well construction shall be in accordance with AWWA Standards A100 and meet the minimum construction standards outlined under State Drinking Water Regulations (18 AAC 80.015). 2. Separation distances between the proposed well location and the property located immediately north (S 'h, SW 1/4, NW 1/4, Section 13, T12N, R3W) shall be physically verified prior to well construction. 3. Decommissioning of the existing private well shall be in accordance with 18 AAC 80.015(d). A Construction and Operation Certificate constituting this approval is enclosed. This approval does not imply the granting of additional authorizations, nor obligate any federa6 state, or local regulatory body to grant required authorizations. 2 February 26, 1999 Mr. Jeffrey A. Gamess, P.E. Thank you for your cooperation with this Department. If you have any questions, please contact me. Sincerely, Steven A. Pettis Env. Eng. Asst. II SP/cf cc: Jim Cross, P.E., MOA/DHHS, w/o end STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION CONSTRUCTION AND OPERATION CERTIFICATE FOR PUBLIC WATER SYSTEMS /SDG --c- Prsj.cf tt,/2f A. APPROVAL TO CONSTRUCT Plans for the construction or modification of C 5 S C �w l cJc4-t' e � Sy 6-E-�. # y Lo f o A public water system located in 50L w t I l, Lakewood lf-, fI s — Alaska, submitted in accordance with 18 AAC 80.100 �e, have been reviewed and are by /Mask < kAJ 4 r a,"dh/ approved. 0 conditionally approved (see attached conditions). TITLE DATE BY If construction has not started within two years of the approval date, this certificate is void and new plans and specifications must be submitted fotreview and approval before construction. B. APPROVED CHANGE ORDERS Date: Change (contract order number or descriptive reference): Approved by: C. APPROVAL TO OPERATE The "APPROVAL TO OPERATE" section must be completed and signed by the Department before this system is made available for use. public water system was completed The construction' of the on (date) The system is hereby granted interim approval to operate for 90 days following the completion date. DATE TITLE BY As-built/record drawings, submitted to the Department, or an inspection by the Department, has confirmed that the domestic wastewater disposal system was constructed in substantial conformance with the approved plans. The system is hereby granted final approval to`operate. DATE TITLE BY Distribution: !. Retain original for project file 2. Make copies for distribution MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On -Site Sewer/Well Permit Application n i 2) . —� �ij — An NOTE: Application must be filled out completely. SI LE FAMILY DWELLING Parcel Identification Number ALa Cl CN Property Owner Name P-4 �(- Day Phone Mailing Address Legal Description Zip Code C�q_2__�kL1 Lot Size n afollowing: Inspec ns wil1con j by: Number of Bedrooms: Approved Engineering FirmMunicipality (permit fee in licec � to Does your house contain anyt Tub, Swimming Pool, Therapy Pool, Jac ez _-'k �> or Water Softener Unit? If yes, which one?r t ny Q uLA This application is for: Sewer Only Sewer and Well Sewer"Upgrade,_ Welll I certify that the above information is correct. I further certify that this application is being ma f inCg:1 F i19 R lin and in accordance with applicable Municipal codes. \ ^\cam v_r, ` L\ 1)n17 Properly Fees: 3 2 h r C)Z) Receipt # f��/ (�� �'�' Permit # 72-012 (Rev. 10/86) Municipality of Anchorage e DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Services Division Telephone: 343-4744 a ON-SITE SERVICES FEE DOCUMENTATION Date Paid: 7-1 Name of Payer: (Name An Ch( Mailing Address: (Off of Legal Description(s): Type of Payment: (Indicate Amount Paid) feafth Authority: i Excavator Permit: Sewer & Well Permit: Engineer Permit: _ Well Permit: Pumper Permit: _ Sewer Permit- - 2 C2J Well Driller Permit: Copy Request: 72-034 (Rev. 10/87) — Tank Manufacturer: (Waste Treatment) DISTRIRI Mint& Permit Number: OS -01111 #: holoi-� WAIVERS: 1' �4 17i s 1 y� c L_(Lot Line: #\T�\_ ��Well to Tank:dc<j c �L Well to Field lc� neo cam' n' Field to Surface Water Tank to Surface Wat Q� - o— � °s``y`a� SENTEC Inc. 7801 E. 36th Ave. Suite A Anchorage Alaska 99504 Phone (907) 333 6881 Fax (907) 333 10§5 July 16, 1995 70�- _ z0 Department of Health and Human Services Division of Environmental Services rT1 v .On -Site Services Section � m o P.O. Box 196650 Anchorage, AK 99519-6650 it's v, N o ® y RE: Sharrock Septic Upgrade Approval L20A Lakewood Hills No.2 Subd . 0 z Sir: Please find the attached application an upgraded drain -field system for the above property. DESIGN NARRATIVE The owners of this lot report that the existing drain field is not absorbing the sewage of the family. The proposed upgrade field will be located parallel to the existing field and tie into the existing tank. A small addition is planned pisiFfed for the house, so an alternate field location is shown and the design will allow for Four bedrooms. Lots in this subdivision are three to five acres in size. All wells and septic systems in the area are greater than 200 ft from the proposed field. The proposed improvements will have no negative affects on surrounding wells or septic systems. There will be no affect to drainage in the area, all water bodies and streams are greater than 200 ft away. There is adequate space on the lot to allow for an alternate drain field. If you have any questions, please give me a call. Very truly yours, { Gr M. s MunWpallfy of Anchorwio - DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 88502-OSW SOILS LOG — PERCOLATION TEST PERFORMED FOR: fn J kG 5 m A R no c_K DATE .LAI<( wpo10 LEGAL OESCRIPTION: U T' 7,o A. 14 tLLS >`/ o. ?_ Township. Range, Seatlon: D£PT14)O �. A,T,. SLOPE, SITE PLAN f p r wTl ITTf 7 ITTr-� 2- 3 3 4- 7 7 s N a LI 10- 11 0 11 i tz � 14 15 18 17 18 is 20 COMMENTS !3 rtcwu 5 +.,T w/ 1 A'qn 13rzo�N Sl�i GTt Av 6 WAS GROUND WATER ENCOUNTERED? �! S IF YES. AT WHAT L D£P��ZTH? �-A O P Mite E Depth to water r ✓ling? Na E Date: PERCOLATION RATE (mmutM/lnch) PERC HOLE DIAMETER 6 ., TEST RUN BETWEEN FT AND '4 FT PERFORMED BY: (_� 01 g cj= M Rm T .V A f^ . I _ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE—' 6 /.T 3 0/ S 72-00a (Rev. 4/85) 07/17/95 16:40 TX/RX NO.0443 P.001 0 i 3 a �■■��� .: r� ®rte PERCOLATION RATE (mmutM/lnch) PERC HOLE DIAMETER 6 ., TEST RUN BETWEEN FT AND '4 FT PERFORMED BY: (_� 01 g cj= M Rm T .V A f^ . I _ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE—' 6 /.T 3 0/ S 72-00a (Rev. 4/85) 07/17/95 16:40 TX/RX NO.0443 P.001 0 i 3 a Tia � � ..,;�:`•: a .. Muniafpatity of Anchorage DEPARTMENT OF HEALTH & HUMAN'SERVICES 825 •'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG —• PERCOLATION TEST" PERFORMED FOR: M 5 pf? V C DATE 1,,, Ak- 4ad o ti LEGAL DESCRIPTION: LOT �D Nb. Township, Range, Section: DEPTH tDX & ` SLOPE SITE PLAN L3R.,w�.1 Slyj 2 3 ) -� �. 4I 6 r �~ G R Avr- L 7 ' �• $ 1 I b 9 10 E1 12 b' G�Db*iE<T 13 N�L.E j 14 15 16 17 18 19 20 COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, ATWHAT DEPTH? MENEM ME IN MEM■ MErMI PERCOLATION RATE S6 (minutevincn) FERC HOLE DIAMETER TEST RUN BETWEEN 3 FTANO —/FT PERFORMED BY: C" G- i CERTIFY THAT THIS) TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: _ ' i n / '.) 5 _T 72.008 (Rev, 4i85) 41 07/17/95 16:40 TX/RX N0.0443 P.002 0 rermiT NO. rage OT W.O. 93234 Municipality of Anchorage Date 7/12/95 Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Bog 196650 • Anchorage, AK 99519-6650 • Tel: 343-4744 On—Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT 20A Lakewood Hills No.2 SUED. PID No. TBM - ASSUMED ELEV-100.0' - SOUTHEAST LOT CORNER MONUMENT CONNECT TO EXISTING PIPE ELEV - -90.2 \ 1 ABANDON FISTING DRAIN FIELD IN P�IACE/ 1 C ALTERNATE FIELD \ O CLEAN T \ 4 N / 1 OU 4- SOLID PVC (TYP) \ 1 G SEE 11 PROPOSED DE SYSTEM SF) 413dr XIS OODO 0 1.2 App. rat. = 500 Iron i ITFST LE \\ \ 4' PE\ PVC (TW) \ 1 DUSTING FIELD \ \ LT 20A OOD HII1S N0.2 SU80. 'Al_ 1 " = 20'\ o \\ U-) OFA (q��1 o O TEST .. ' rn \Ar 0 00 Q� . ••• 00 \\ O-T) f A GREGOR P �•y / \••a CE 7892 �.�ll� r MONITOR TU E 4���'r••••••••••• \ \ \ Professt ♦♦ ATE 141jL%"* Permit No. Pageof W.O. 95234 Municipality of Anchorage Date 7-12-95 Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Boz 196650 • Anchorage, AK 99519-6650 • Tel: 343-4744 On—Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT 20A Lakewood Hills No.2 SUBD. PID No. GEOTEXTILE FABRIC. SEE NOTE 13 3'-6" MIN. COVER (3'-0" MIN. RESTOR EXIST. GRADE AFTER CONSTRUCTION AFTER SETTLMENT) SEE NOTE 15 4" CLEANOUT 4' MONITOR TUBE1 � �X/SnNG \ \ SFp77C k N 4.5' -SEWER ROCK PER MUNICIPAL SPECS. SEE NOTE 10 2' MIN TRENCH WIDTH 4" PERF_ PVC (TYP) INVERT = 84.5' A TYPICAL SECTION N.T.S. Permit 1'4'O. Page_ot W.O. 95234 Municipality of Anchorage Date 7-12-95 Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, AK 99519-6650 • Tel: 343-4744 On—Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT 20A Lakewood Hills No.2 SUBD. PID No. NOTES:^ 1 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATION OF THE MUNICIPAL CODE AS CURRENTLY AMENDED. 2 SITE TOPOGRAPHIC SURVEY CONDUCTED ON 6-6-95. EXISTING STRUCTURES SHOWN ON SITE PLAN ALL LOTS IN SUBDIVISION SERVED BY INDIVIDUAL WELLS 3 ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO ITS INCORPORATION INTO THE SYSTEM. 4 CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATER WAYS, SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. NOTIFY THE ENGINEER OF ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION. 5 NOTIFY THE ENGINEER 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF THREE INSPECTIONS ARE REQUIRED. THE FIRST INSPECTION SHALL BE OF THE SUBGRADE, PRIOR TO PLACING SAND FILETER. THE SECOND INSPECTION SHALL BE AFTER THE PLACEMENT OF GRAVEL, DISTRIBUTION PIPING, STANDPIPES, TANK, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD INSPECTION SHALL BE AFTER THE WORK IS COMPLETED. 6 CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED -LINED, AS -BUILT DRAWINGS SHOWING ALL DATA AS SPECIFIED IN SEC. 15.65.F.2, 3, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN TEN DAYS OF THE FINAL INSPECTION. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE AS-BUILTS SHALL BE USED TO DOUBLE-CHECK THE ENGINEER'S INFORMATION PRIOR TO SUBMITTAL TO DHHS. 7 STAKE ALIGNMENT OF SYSTEM WITH MARKERS SHOWING THE PROTECTIVE DISTANCES FROM WELLS AND OTHER BODIES OF WATER PRIOR TO BEGINNING INSTALLATION. g ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER. 9 EXCAVATE THE ABSORPTION FIELD. BOTTOM OF EXCAVATION SHALL BE FREE OF ORGANICS AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE, AND END OF BED BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 10 PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE ROCK WITH NATIVE MATERIALS OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO f 1" PRIOR TO INSTALLING THE PERFORATED PIPE. 11 ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER -APPROVED EQUAL. 12 GEOTEXTILE SHALL BE MIRAFI 1405 OR ENGINEER -APPROVED EQUAL. LAP ALL JOINTS 2' MIN. 13 MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 14 SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MIN. SLOPE, AND 3:1 MAX SLOPE, AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MUNICIPAL SPECS. v,sQ ZZ) r,l/vim S�i� f� X / /7 a 7 No. 7678 Sold To C La eu"3(�e�& AWS Shipped To / g� Address__ RECEIVED JUN 51995 IViunic.paitty vi Hnchoragq Dept. Health & Human Services DATE SALESMAN TERMS F. O. B. VIA �4/ Y A Z E' f / 00 ze LO Y w I I IF O— i 2L r i 741729 ® Afton