HomeMy WebLinkAboutELMORE #2 BLK 9 LT 11Rick Mystrom,
Mayor
Mmficipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
ht~p:'/www.cianchorage.ak.us
343-4744
December 8, 1998
Mary C Britton
1531Northview Driev #8
Anchorage, Alaska 99504
2849
Subject: Lot 11 Block 9 Elmore #2
Permit ~SW970409, PID #018-173-23
The subject permit, issued Decemb'er 4, 1997 by this office for a
single family well and/or on-site wastewater system, has
expired as of December 4, 1998.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If y~ ~have any questions, please call this office at 343-4744.
rely,
J~me~ Cross, P.E.
P~/ogram Manager
O~-site Services
enc: Copy of Permit
cc: Phukan & Sorenson Consulting
PAGE I OF I
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREETt ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW970409
DESIGN ENGINEER:~HUKAN & SORENSON CONSULTING
OWNER NAME:MULLIS HARVEY D & BEVERLY J
OWNER ADDRESS:4301 E 147TH AVE
ANCHORAGE, AK 99504
DATE ISSUED:12/04/97
EXPIRATION DATE:12/04/98
PARCEL ID:01817323
LEGAL DESCRIPTION:
ELMORE ~2 BLK 9 LT 11
LOT SIZE: 39520 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
~-KMINIMUM~OFi2' INSpEcTIoNs ~RiNG ~bNSTRUCTIONMUST BE /
I~-['~INSTALLATION OF THE SYSTEM MUST BE DONE BY AN EXCAVATOR,/
iAPPROVED BY DHHS./
DATE:
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUM~ SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW970007
DESIGN ENGINEER:PHUKAN & SORENSON CONSULTING
OWNER NAME:MULLIS HARVEY D & BEVERLY J
OWNER ADDRESS:4301 E 147TH AVE
i~NCHORAGE, ALASKA 99516
DATE ISSUED: 1/13/97
EXPIRATION DATE: 1/13/98
PARCEL ID:01817323
LEGAL DESCRIPTION:
ELMORE #2 BLK 9 LT 11
LOT SIZE: 39520 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) liND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED kND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
--- ~.~ . _
~--:~t.'~ PHUKAN CONSULTING ENGINEERS & ASSOCIATES, INC.
Civil · Geotechnical · Surveying · Environmental
November 22, 1996
W.O. # 96153.1
Municipality of Anchorage
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK 99519-6650
Re:
ON-SITE SEWER/WELL PERMIT
Dear Sirs:
RECEIVED
At the request of Mary Britton, Phukan Consulting Engineers & Associates, Inc. (PCA)
performed a preliminary investigation at the property with the legal description of Lot 11,
Block 9, Second Addition to Elmore Subdivision. The purpose ofthe investigation was
to determine the suitability of the subject property for development and on-site
wastewater disposal. Two test pits were dug at the property. Their locations are shown
on the enclosed site plan. Both test pits revealed an organic mat to an eight inch depth
underlain by sandy silt from eight inches to 33 inches below the existing ground surface.
Below the sandy silt, from 33 inches to eight feet deep is sandy gravel with cobbles.
Ground water table was encountered at about seven foot depth in both test holes. Ground
water was then monitored at both locations from September 14 through October 18, 1996.
(Ref. attached Table). The highest water level was observed October 16 at Test Hole # 1,
where the water level was 73.5 inches below the existing ground surface.
A percolation test was conducted eight feet east of Test Hole # l, at a depth of four feet
within the sandy gravel layer. Test results indicated a percolation rate of 3.5 minutes per
inch. (Ref. attached test results). This is consistent with the visual soil classification and
observed percolation rates on neighboring lots.
Based on thc field investigation results, a five foot wide standard shallow trench disposal
system has been designed for the leach field. To insure a four foot separation distance to
ground water table, the base of the trench will be two feet below grade. The sandy silt at
this level will be removed and replaced with filter sand. The trench was sized for the
proposed three-bedroom house using an infiltration rate of one gallon per day per square
foot, and an application rate of 150 gallonspcr bedroom per day. A total infiltration area
of 450 square feet is proposed.
There is minimal probable impact from the proposed wastewater disposal system to
adjacent property. Wells are over 200 feet away from and up gradient of the proposed
absorption trench and will not be affected. Existing wastewater systems are over 100 feet
2702 Gambell, Suite 201 · Anchorage, Alaska 99503 · (907) 272-7111 I FAX 277-3177
Department of Health and ttuman Services
November 22, 1996
· Page 2
away and also, will not be impacted. Reserved space and drainage on adjacent lots will
not be affected.
It is concluded and recommended that the proposed wastewater disposal system when
constructed in accordance with the enclosed drawings and specifications, will not
adversely affect ground or surface water quality or punic health. As such, permit should
be given for the construction of the proposed septic system and a water well at the
property as indicated.
Should you have any questions, please do not hesitate to contact us.
Sincerely yours,
PIIUKAN CONSULTING ENGINEERS AND ASSOCIATES, INC.
Dr. Arvind Phukan, P.E.
Principal
Filc: 153Itt.doc aa
k~, .~..2.,..~ ~ ·
'O U N DATI O N
WALL
4" INSPECTION
PIPES
~CLEANOUT
MONITOR TUBE
4" PERFORATED
PIPE. O,GRADE
SEPTIC
TANK
ABSORPTION
TRENCH
)UNDATION
WALL
INSPECTION
-CLEANOUT
4" SEWER
PIPE 0-2%
GRADE
MONITOR
MIN. GRADE
qlTOR TUBE
CLEANOUT
GALLON
2 CHAMBER
SEPTIC TANK,
INSULATE TOP
OF TANK
CLEANOUT
INOTE.' CLEANOUT I
LOCATIONS AS ABOVE I
AND AT EACH END OFI
ABSORPTION TRENCH I
SEPTIC
MARY BRITTON
SYSTEM, AND CLEANOUT
LOCATION PLAN '
PHUIfAN CONSULTING ENGINEERS & ASSOCIATES. INC.
Clvil· Ceotechnic~l * Sur~eyin~ * Environmental
2702 Gambell, Suite 201, Anc.h. orage, AK 99503
Tele: (907) 272-7111 Fax. (907) 277-3177
w.o. 96153.1J~OMP. inLE 1535EC SCALE N/A DATE1/lO/97 J.RUIZ
SPECIFICATIONS FOR WASTEWATER DISPOSAL SYSTEM.
LOT 11. BLOCK 9. SECOND ADDITION TO ELMORE SUBDIVISION
Septic tank shall be Municipality of Anchorage approved, two compartment, installed
level, minimum volume 1000 gallons. Couplings on inlet and outlet shall be watertight.
Manholes shall be equipped with watertight gaskets. Tank and solid sewer pipe shall be
set on stable, well compacted soil.
Solid sewer pipe shall be PVC conforming to ASTM D3034. Perforated pipe shall be
PVC conforming to ASTM D303, ASTM F789 or ASTM FA10.
Insulation shall be at least two inches of direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Filter sand must be of naturally occurring material. Less than 4% must pass the No. 100
U.S. Standard Sieve and less than 2% must pass the No. 200 U.S. Standard Sieve.
Trench bottom must be level throughout.
Perforated pipe must be installed level with perforations do~vn.
Smeared trench bottom must be raked or scarified prior to washed rock placement.
Avoid compaction of absorption trench bottom and adjacent area.
Plumbing workmanship and materials shall conform to the Uniform Plumbing Code,
1994 edition and Municipality of Anchorage Standards and Specifications.
File: 153spec2.doc
4" MONITOR TUBE
PERFORATED WITHIN
WASHED ROCK ZONE
TOPSOIL
ORIGINAL GRADE
PERFORATED PIPE
0 GRADE
INSULBOARD
3/4"-2-1/2"
WASHED ROCK
EXCAVATE
SANDY SILT, REPLACE
WITH FILTER SAND TO
ELEVATION OF TRENCH
Z
BOTTOM
5.0'
WIDTH Of WASHED ROCK
AVOID COMPACTION OF
SANDY GRAVEL AND FILTER
SAND. LEVEL FILTER SAND
AT ELEVATION 2.0' BELOW
HIGHEST ELEVATION WITHIN
TRENCH FOOTPRINT
~C?GINAL
I MARY BRITTON
C SYSTEM, TRENCH CROSS SECTION
...... ~ AT MONITOR TUBE
· "~KAN CONSULTING ENGINEERS & ASSOCIATES, INC.
'~Civil * (;eotechnical · Surveying * Environmental
~ 2702. Gambell, Suite 201, Anc.h. orage, AK 99503
~ Tele. (907) 272-7111 Fax. (907) 277-3177
i..o. ? leo.,. F,~c ,,,.scclsc~ .xA {~,,c,,/,3/96 B~ J.RUIZ
-- ~-G~t, IEER'S SEAL}
Municipality ol Anchorage
DEPARTMENT OF HEALTH & HUMAN sERVICES
825 "L" Street. Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION 'TEST
DATE PER F ORNI ED: ''--~ ~' '~ / ~
pERFORMEO FOR: ~
, ~ ~, S~ti~: ~ sITE PLAN
LEGAL DESCRIPTiON: L~ II ~ e~ ~$~e~ S/OPE
11
13
14
WAS GROUND WATER
ENCOUNTERED' ~ S1
IF YES. AT wHAT , t_ O t~
DEPTH'
Drop
15
17-
18'
19
.:
CE-5227
pERCOLATION RATE '~..~.4~ _ [m,nutes.,incnl pERC HOLE OIAMETER ,,~4,
TEST RUN EETwEEN -~ o _ FTAND ~ '~' FT
~OMMENTS
~S(TEST WAS PERFORM:
pERFORMED : .... ~e,~ ON THIS DATF- DA ' -- .
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINE5 tm crrr.~T
TABLE 1:
Monitoring of Ground Water Table
Lot 11, Block 9, Second Addition to Elmore Subdivision
TEST HOLE # 1 TEST HOLE # 2
Ground Water Level Ground Water Level
DATE 3elow the Ground Surface Below the Ground Surface COMMENTS
09/14 6' 6" 7' 6" Rain
09/16 6' 6" 7' 6" Rain
09/17 6' 8~" 7' 10" Rain
09/18 6' 11" 8' 1½" Rain
09/19 6' 11" 8' Rain
09/21 6' 9" 8' Rain
09/25 6' 7" 7' 9~" Rain
09/28 6' 6~" 7' 9" Rain
10/02 6' 5 ½" 7' 8"
10/05 6' 2½" 7' 5"
10/08 6' 3" 7' 6"
10/11 6' 2- 7' 4½- -
10/16 6' 1½" 7' 4" Snow
10/18 6' 2" 7' 4%" Snow
: 153Table.doc
LOCATION OF WELL%.~.)t
STATE OF ALASKA
· DEPARTMENT OF NATURAL RESOURCES
DIVISION OF MINING & WATER MGMT
WATER WELL RECORD
r-IN , DE
Ds ,
LOCATION/SKETCH:
~EASURED
BOREHOLE DA?~.
Material Type ~'~]' Color
casing top I--Iground surface
Depth
· From To
,WEL~'OWNER:
WELL 4: DATE OF COMPLETION
Depth of hole:~__,~_ ft
Depth of casing:~....-- ft ~/~ I/.~ f ~'~
DEPTH TO STATIC WATER LEVEL:
J~"~ ft below~C~, top of casing
Date: '
ground surface
METHOD OF DRILLING: ~[] air rotary r-I cable tool
[] other
USE OF WELL: J~- domestic [] irrigation [] monitor
[] public supply ~] othet
CASING STICK-UP: ,~ ft. Diam: ~_~ in. {o,~ ft
Casing type: ..~ ' ,~ in. to ,f' Z-ft
WELL INTAKE OPENING TYPE: ~' open en<] [] screened
[] perforated [] open' hole
Depths of opemngs: ~ to ft
SCREEN TYPE: Diam: in,
Slot/Mesh Size: Length: ft
GRAVEL PACK TYPE:.
Volume u~ed: --Depth to top: -'
GROUT TYPE: a~M~y__~V o ~
Depth: from ft to ft
RECEIVED
DEVELOPMENT M -
Duration: '
DEC 2 1998 PUMPING LEV'EL AND YIELD:
~ ft after ~ hfs pumping ~ gpm
PUMP INTAKE D£1q'H: ft Horsepower:
WELL DISINFECTED UPON COMPLETION? ~ YES [] NO
CONTRACTOR INFORMATION:
REMARKS:
PLEASE MAIL WHITE COPY OF LOG TO:
DNRIDIVlSlON OF MINING & WATER MGMT
3601 C St, Suite 800
ANCHORAGE AK 99503-5935
Phone (907)269-8639, Fax (907]562-1384