Loading...
HomeMy WebLinkAboutT15N R1W SEC 8 LT 82T15N RIW 5E¢ 8 Lot 82 #051-0c)2-25 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101200 05109225000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: October 21, 2010 to October 21, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T15N R1W SEC 8 Site Legal Address: T15N R1W SEC 8 LT 82 G:1357 Owner/Address: COTHRON CLARK E & TONI L PO BOX 672566 CHUGIAK AK 995672566 l)~.'t. a r t~:z'~e:l~t Site Mailing Address: 20470 CRABTREE ST, Chugiak Lot Size in Sq Ft: 108900 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The Final Inspection Report will not be approved until the well in the easement is resolved and the well log (Sullivan?) has been submitted. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 · ON-SITE SEWER/WELL PERMIT APPLICATION U'~',',*.~c, ot, P/ol~.~! FOR A SINGLE FAMILY DWELLING /~,.~,'~: ~..~? 1~/ZOO Parcel ED. O,..¥ Property owner(s) CLARK COTHRON Dayphone 229-2177 Mailing address P.O. BOX 672066, CHUGIAK, AK Site address '~0 ~ '~ 0 ¢,~-~r¢~ .~'1~ Zip Code 99567 Legal description (Sub'd, Block & Lot ) LOT 82 Legal description (Township, Section & Range) Lot Size / (~.~ ~00 Sq. Ft. T15N. RlW. SECTION 8 Number of Bedrooms THIS APPLICATION IS FOR ( [~all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct, i further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. '°~ ......... ' .....'~ ......... c,r authori od agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) ,,,,¢.-.~ Lf~ Waiver Fees: Date of Payment: Receipt Number: Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchora,qe, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 htt p://www.m u ni.or.q/Onsite Development Services Department On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** WaiverS: OSP101200 COSA#: PID#: 054-092-25 Legal Description: T15N RIW Sec 8 Lot 82 Engineer: Garness Engineering Group Permit~: OSP101201 Applicant: Clark Cothron Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 35.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: Name of Reviewer~ Rec~: 008405 Amount: $200.00 Date Paid: 9/17/10 **** VARIANCE/WAIVER REVIEW **** GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS August 25, 2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for T15N, RIW, Section 8, Lot 82 To whom it may concern: The existing 3 bedroom house is served by a private well and undocumented septic system. The owner is required to relocate the house on the property due to not meeting zoning setback requirements. Attached is a site plan and design drawing which show the existing house location and the proposed relocated site. The owner obtained a well permit, but did not obtain a septic permit. Per the owner, the septic system consists of a septic tank that is being used as a holding tank. A test hole was recently excavated on the property that was logged by Robert A. Shafer, P.E. We are proposing to that a new 1000 gallon septic tank and a dual 5-wide trench type drainfields be installed. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the drainfield is a 2 to 8 percent slope running approximately south to north. There is a slope that exceeds 25 percent approximately 35 feet down hill from the proposed drainfields. We request a 35 foot waiver to the slope. Attached is a profile drawing that shows that at a 25 percent slope, orginating 2.5 feet above the top of the distribution line, the slope does not daylight 50 feet downhill from the trench. We are unaware of any adverse impacts with the granting of this waiver would create. We are If you have adverse impacts this installation would have on adjacent wells or septic systems. please contact us at 337-6179. Thank you for your assistance. P.E., M.S. Pres: NOTE: ~ttached is a site plan drawing, a design drawing, a profile drawing, and one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com I LOT 68, SECTION 8, LOT 67, SECTION 8, T15N, RlW T15N, RlW SERVED BY PRIVATE WELL SERVED BY PRIVATE WELL ~ AND SEPTIC SYSTEM. NO AND SEPTIC SYSTEM. NO ENCROACHMENT CONCERNS ENCROACHMENT CONCERNS i SCALE: 1" = 100' ~ / / I ~o , /~e~ EXISTING 3 BEDROOM I "u/u~: HOUSE TO BE RELOCATED : ON P.OPE.~ I X i z LOT 81B, SECTION 8, EXISTING HOLDING --~~;.-.,. '-:-::- .~:'~:~ ~?'~.~::'~ :,?~g';';'?~'".t "~ '~¥ ?-. ~ C :~' ALTERNATE SITE~ ~~ ~~...,.~ ;. ~...,,.-'~.- .-~Z :..,.?;'; '....,'~ ¢ :';'~' ','~.'~.~.~".~... ~.?.:' · · . ..... ~'-: MCKINLEY VIEW AVE. (UND~ELOPED) m RISU-TOM~ S/DII TRACT A LOT 96, SECTION 8, DIsH ~"av ~,n ~ ~ T15N R1W ..... - ........ /~ 4~ _~. ).~- SE~ED BY PRIVATE WELL SER~D BY PRIVATE WELL ~0 AND SEPTIC SYSTEM NO ~ ~ AND SEPTIC SYSTEM. NO - ~ ~ ~. ENCROACHMENT CONCERNS ENCROACHMENT CONCERNS ,9~.'~~ mI PREPARED FOR: IPHONE NUMBER: I PAGE NUMBER: 1,~ CObh.ON I 22 -2 7 o[ LEGAL DESCRIPTION: DroWN BY: X~A~' ]/.j' CE7795~ LOT 82, SECTION 8, T15N, RlW J.L.M. X'%.*. SITE P~N FOR SEPTIC SYSTEM UPGRADE 8/25/2010 Municipality of Anchorage Mark Begich, Mayor Building Safe Division P.O. Box 196650 ® 4700 Bragaw Street Anchoragc, Alaska 99519-6650 · (907) 343-8301o F,~x (907) 343-8200 h ttp://x~v muni.org July 28, 2003 Clark Cothron P.O. Box 672566 Chugach, AK 99567 Subject: On-Site Water and/or Wastewater Permit. Permit Number: SW020310 · ' ,~I'SNR:IW'SEC8 Lot 8~ Legal D escnptmn. ~L?~'~.,~:: .:~, .~,~,.~...~. ~ Dear Clark Cothron: An On-Site Water/Wastewater Permit, number SW020310, issued by this office for a single-family system, will expire on August 22, 2003. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as-built inspecti6n report must be sent to this office for review, approval and documentation. This as-built inspection report must be signed by the licensed Professional Engineer who inspected the installati°n Of the sYsteml AszbUilt inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and $150.00 for a well permit. If you h/~ve any questions, please call this office at 343-7904. ger ' ' On-Site Water and Wastewater Program Enc: Copy of permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Streel P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Aug 22, 2002 Expiration Date: Aug 22, 2003 Permit Number: SW020310 Legal Description: T15N R1W SEC 8 LT 82 Design Engineer: 0000 None Required Owner Name: Clark Cothron Owner Address: PO Box 672566 Chugach, AK 99567- Parcel ID: 051-092-25 Site Address: Lot Size: 108900 SQ~ FT. Total Bedrooms: 0 Permit Bedrooms: 0 This permit is for the construction of: ~] Disposal Field []] Septic Tank [~ Holding Tank ~ Privy Private Well Water Storage AII construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. ReceivedBy: 0 ~J~ ~ , ssu ed By: Z~"~'~f',,~//-~(~' ~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Property owner(s) M~iiJng address (1 Day phone Permit Number SW ~_..~2_~.~./O~ Mailing address (2). Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) Lot Size ) 6 $; ?Of~ ~ '?"/' Acres/Sq. Ft. THIS APPLICATION IS FOR: Sewer Only [] Sewer and Well [] Sewer Upgrade [] THIS PROPERTY CONTAINS: Hot Tub [] Swimming Pool [] Therapy Pool [] Zip Code Number of Bedrooms Well Only Water Storage Jacuzzi [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwe~nd~,~ in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: 330.20 BLM OLD CRA~ERRY Noo'.la'OO"W 2~,$.~_-_..,(Co,~p) 297.21 NOO°16'OS"W 32971 (7: 330.20 0