Loading...
HomeMy WebLinkAboutFASSLER LT 3Fussier Lot 3 #051-531-34 Municipality of Anchorage Page 1 of 3 Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 w .&anchorage.ak.us (907) 3437904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO10082 PID Number: 051-531-34 M": MM&M ContractingWastewater System: New Aaaass: P.O. Box 670495 Chu iak AK 99567 ABSORPTION FIELD °oa'" "'"n°°`aeeda"" : 688-1236 Three 3 Deep Trench LEGAL DESCRIPTION Ta Depth k.er.y.W9.aee. 1.2 Gpme 9.0 Ft. bock W: Subdw.m: DeDN b ptw bottom Man a1.w yraee: Cx Impin Cm ,, pp: 3 Fassler Subdivision 3.0 Ft. 6 FL Toawq: Rage: Sectors: F. waea abo.e aq+w ir+be: Dr.M Lmgm: 1 Ft. 39 Ft. Well: New 3 '' 1! 'N'/FL N/A A Ft. FL CWnft ban (Pm G. A B. C): TaW Depth: Cnee W. rdd obwPeon area: F" ma ami. Private 200 Ft.161 Ft. 468 Fe ASTM D3034 PVC pneer. Dara D U ; $b Waw Levet: k M4Mbf. Date MUYeee: Sullivan Water Wells 7/18/2001 147 Ft. MM&M Contracting 8/11-25/01 rave. PM Set M:Ca" AbeveCr : TANK 2 GPM Ft. >2 Fl SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To From Septic Tank Absorption Field Llft Station Holding Tank rivate sewerurro Anchorage Tank 1,000 we$ >100' >100' N/A N/A >25' m. Steel Two (2) S.Wewatn >100' >100' N/A N/A LIFT STATION — NONE ON LOT LW tine >5' >10, N/A N/A Dr. WLY Fe.rbeux, >5' >10' N/A N/A Pm w° M. .ata at ti. b in. INone Noted I I °inipMake &W N M"°°p'""ptr1ana0Dy c.1m,Dnb 22Insulation nsulation Over Septic Tank. BENCH MARK Top of Well Head. Amoned r:tembn: 100.0 FL ngineer s btamp ..•••��wa�a�4Ma �� 111 • ..'� 3 49th •s=♦♦� Inspections performed by: MEA Dates: 1" 8/11/01 2n0 1/19/0G y MICHAEL E. ANDERSON {� ♦♦,f%f+".O Department of Health and Human Services approval CE -43 81 • 11 �� ll/ � �' 2 2 � Reviewed b Date: �0") 1 IMM ES :'•• �r sta' • and approved : • rn PP Y ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) MEMORANDUM DATE: January 20, 2002 TO: Jeff Poet/Dan Roth FROM: A �/� Mike Anderson, P.E. �✓�1�-- SUBJECT: Lot 3, Fassler Subdivision Test Hole Locations The test hole locations shown on the septic system as -built are the actual surveyed locations of the holes. The locations shown on the septic system design were based on field measurements, which turned out to be inaccurate. The septic system absorption trench was constructed entirely within the 30' radius of Test Hole No. 1. We apologize for any confusion this may cause. Please let me know if you have further questions concerning the test hole locations on this lot. Municipality of Anchorage Page 2 of 3 DEVELOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519-6650-343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit N ber SWO10082 PID No. 051-531-34 _0�"_444_ 7II2 ® �Iternate TH1 Site 49tn-6V�'�I•�: I \ \ 1 i1eI1 M-CHAEL E. ANDERSON S, No. CE -4381 o 15 Ilgli FASSLER CIRCLE PLAN AS -BUILT SCALE 1" = 40' A B S1 36.6 27.1 S2 0.9 31.1 C4 8.9 48.4 M1 !43.3 45.7C5 9.5 30.7 49tn-6V�'�I•�: I \ \ 1 i1eI1 M-CHAEL E. ANDERSON S, No. CE -4381 o 15 Ilgli FASSLER CIRCLE PLAN AS -BUILT SCALE 1" = 40' Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW010082 v2 Ln L) 2 ' U PID No.: 051-531-34 e I r I fifle BOX 670=. CHUGEWALASO FROM ■ COU!,ffRY FSPIL-TY r.:v-vvrA MetiiOd'bfDisinfection: `iWi OWNER OF rA .1, All :S LEGAL DESCROTION:142a7 : 3. e I r I fifle PHONE NO. : 9076881239 • BOX 670=. CHUGEWALASO Weli Disinfea66 Upoirl Co;�pletion?.b'-Ie'ilb -DEPTkj * r.:v-vvrA PHONE NO. : 9076881239 • BOX 670=. CHUGEWALASO Weli Disinfea66 Upoirl Co;�pletion?.b'-Ie'ilb -DEPTkj * MetiiOd'bfDisinfection: `iWi OWNER OF .1, All ADDRESS:. - LEGAL DESCROTION:142a7 : 3. ;C- 4 , -rSeC.#L Z. DATF_ • PERMIT NUMBER:-0-LQJ-Lj-- Dite of is TAX IDENTIFICATION NUMBER:: . Is I locat&d at approved permit location? u Yes* C, Method of Dri ary.:u cable tool Depth- of well: Casing Type f-'Lr4F Wall T'hickn*es*s Diameter (a! Inches, depth Liner Type: Casing StickupAbove.Ground;' feet' Static Water Level; ---feet 7 Recover Rate: Method of Testing; '411 Well Intake Opening Type: 0 open.end (loped h6le Ci Screehed; t stan f6ei Stopped feet 4-Krforatjc*ni. Start, Z-fe-et p p e d Groui Type: Aer-J121- r. 4 "the propt A Human .Received Time' 6e c -27. :'#'A.*("' Dec. 27 2001 09:01AM P1 rtrr[r�g ogz. d .4 IT -ER:. -W -ELL -,S`-'-' ;�R6N%'E IMS -2750 t* Weli Disinfea66 Upoirl Co;�pletion?.b'-Ie'ilb -DEPTkj * MetiiOd'bfDisinfection: `iWi 6A 4 Jit #+-j4o 4, "the propt A Human .Received Time' 6e c -27. :'#'A.*("' Dec. 27 2001 09:01AM P1 rtrr[r�g ogz. d .4 IT -ER:. -W -ELL -,S`-'-' ;�R6N%'E IMS -2750 t* mita copy Of the -Well 109 to the Pr0W'WthOrIty..Munic.iI5ao�- uepartment I of Env . Ironmental Conservation. MatSu'Boi6 -DEPTkj 6A 4 Jit #+-j4o S OjA -Odcc V ..J 7 ia7 YA* mita copy Of the -Well 109 to the Pr0W'WthOrIty..Munic.iI5ao�- uepartment I of Env . Ironmental Conservation. MatSu'Boi6 MUNICIPALITY OF ANCHORAGE l Pol Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Apr 25, 2001 Expiration Date: Apr 25, 2002 Permit Number: SWO10082 Parcel ID: 051-531-34 Legal Description: 'FASSLER SUBDIVISION LOT 3 Design Engineer: 0014 Anderson Engineering Site Address: NHN FASSLER CIRCLE Owner Name: MM & M CONTRACTING Lot Size: 29639 SO. FT. Owner Address: PO BOX 995657 Total Bedrooms: 3 Permit Bedrooms: 3 CHUGIAK . AK 99567 - This permit is for the construction of: [✓� Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued Date: °r'35 a of Date: it2.50l Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 05-1 — 331 — 34 Permit Number SWO10082 Property owner(s)_MM&M Contractinq Day phone 688.1236 Mailing address (1) P.O. Box 670495 Chugiak, AK 995657 SITE Meilit address(2)YHA/ 8/455LER C1R6Lr_r Zip Code 99567 Legal description (Lot, Block & Sub'd.) Lot 3. Fasster Subdivision Legal description (Section, Township & Range) Lot Size 296 17 Acres/ THIS APPLICATION IS FOR: Number of Bedrooms Three (3) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. E Com„ (Signature of property owner or authorized agent) Permit Fees: Waiver Fees: Date of Payment: 4,13007 Date of Payment: Receipt Number: Receipt Number: (Rev. 12100) April 12, 2001 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street ' Anchorage, AK 99519-6650 Subject: Lot 3, Fassler Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 3, Fassler Subdivision intends to place a new 3 -bedroom home on 'the lot. We are therefore applying for a permit to'construct a septic system on the lot to serve the proposed home. The lot is currently served by.a'community water system. The attached Site Plan and backup documentation identify, the location and configuration of the new septic system and the parameters used in the design. It also shows the location of the water service line and the alternate septic site. Existing . drainage patterns are shown and will not be altered by the development of the lot. Two test holes were placed at the "proposed location for the new and alternate absorption trenches and revealed well -graded gravel with minor amounts of silt. No groundwater was noted in the test holes during excavation and none was noted during the monitoring period. The soil percolated at a rate of 1 minute per inch. Conditions are excellent for an onsite septic system. We are therefore proposing to place a 3' wide by 32' long by 6' effective depth absorption trench to treat the septic effluent. The pipe will be placed at 3' below the existing ground surface and the total depth,of the trench will be 9'. A minimum of 3' of cover will be placed over the bed to prevent frost penetration and possible freezing.' The ground surface on the lot slopes as shown on the'attached Site Plan with slight grades from south to north and west to east. The new trench will be constructed . parallel to the contours of the surface in conformance with Municipal requirements. Grading will be accomplished to assure surface drainage is away from the new trenches. The existing drainage pattern on the lot will not be affected during development. If the system is constructed In accordance with our design the following statements • apply:. 1. The system, If constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 'The lot is currently served by a community water system. Lot 3, Fassler Subdivision April 12, 2001 Page Two 2. The system, if constructed as designed, will have no adverse impact on existing . septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse Impact on reserve space, either surface or subsurface, on any lots located In the area. 4..The system, if constructed as designed, .will have no adverse Impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely; ee\\L\p,l s•� E��p Michael E. Anderson; P.E. ` �� OF Attachments .40 TH MICHAEL E.•ANCERSCN •,^--r CE -4381 unsubdivided (Vacant) 30 „ h - 30 n O O 1 � 33 1 �I� 609s I I •! C 33 4 I THIS PROJECT :•'~ / .�YlT -d :.• �- / / « � � i�yD tom. : g •j16p1 / / �:7 �\O � � _ n ME 22333 n ^^ ♦' 957.17 RDM' 14: LAST / 506 (72-f56) 19.85 •f ,. AREA MAP SCALE I"= I 00': �•' OF 4 4 e .......... o moi,• • � ^• �✓ �'•�_ ', ,49TH so r• MICHAEL E ANDERSCN :?: 0 ,i CE -4381 �H2 terna _ to U NOTE: This Subdivision and I those in the area are served by a community water system. There are no conflicts between the an�rfhosenin ��ietarealot . qq Z6'LEffectir ve SITE PLAN SCALE 1" = 40' \OGa" 1,Ion Septic Tank Three Bedroom House I I I I W v W J N N lat. OF.. Al Te .... 49 MICHAEL E. ANDERSON P ter'• CE - 4381 r s LOT 3, FASSLER SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Deep Trench System Perc. Rate: 1 MinAnch 1,000 Gallon Septic Tank Application Rate: 12 GPD/SF 6' Drain Field Rock 3 Bedrooms X 150 GPD 112 GPD/SF = 375 SF of Absorption Area 375 SF112SFILF = 3125 LF Trench Length Therefore: Construct an Absorption Trench 32' in Length by 3' Wide With 6' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground. Total Depth of Trench to Be 9' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. OF eg Minimum 6' Separation From Bedrock Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. 4 9.LH Minimum 10' Separation From Water Service Line. '0.../ ........ ... ... * �, 00 01 'p„ MICHAEL E. ANDERSCN J� CE • 4381 Ilk PROFES%jOLI��� ts\������� Natural 2.6., i Backfill -. - Geotextile 60 y :Fabric O' 4^ Perforated _ PVC (Slots Down) 6, Drainfield' ' Rock' L JR. - .3. 39 TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. OF eg Minimum 6' Separation From Bedrock Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. 4 9.LH Minimum 10' Separation From Water Service Line. '0.../ ........ ... ... * �, 00 01 'p„ MICHAEL E. ANDERSCN J� CE • 4381 Ilk PROFES%jOLI��� ts\������� 2 3 4 5 6 8 9 NA 13 R, 17 PERFORMED FOR: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST M R M CONTRACTING LEGAL DESCRIPTION: LOT 3 FASSLER SUBD TEST HOLE # PT / OL PERC.LEVEL WELL -GRADED GRAVEL -SAND -CLAY MIXTURES WITH COBBLES: GC WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH TO WATER AFTER MONITORING: DATE: BOTTOM OF HOLE COMMENTS: TEST HOLE PRESOAKED PRIOR TO TEST. NO S L 0 None E 4/12/01 40�_ OF A4 49 -LH Y e 0 .............. • MICHAEL E. ANDERSCN•Oro' CE • 4381 . �= DATE YLTk KiSMIff6V) �%1903/2001 G'L%` SITE PLAN 0% READING DATE O T DEPTH OF WATER NET DROP T0 2 2.00 N s 1 2.10 10 L 3 91/2 - to u 12" 2 u 10 21/2" 91/2" Recharge I I 1 0% READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 3 -April 2.00 12" 1 2.10 10 21/2" 91/2 - Recharge 12" 2 2.20 10 21/2" 91/2" Recharge I I 1 1 12" 3 2:30 10 21/2" 91/2" PERC RATE:i•I MIN./INCH PERC. HOLE DIAMETER: 6' TEST RUN BETWEEN 4.5 FT. AND 5.5 T. TEST PERFORMED BY: T.L. KIM13ROUGH 1, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES ON THIS DATE: 4IZ-0 2 3 4 5 6 7 8 9 PERFORMED FOR: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH S HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST M E M CONTRACTING LEGAL DESCRIPTION: LOT 3 FASSLER SUBO TEST HOLE # 1 SLOPE PT/OL PERC.LEVEL WELL -GRADED GRAVEL -SAND -CLAY MIXTURES WITH COBBLES: GC WAS GROUNDWATER ENCOUNTERED? NO 0 NO 10 IF YES, WHAT DEPTH? DEPTH TO WATER None 11 AFTER MONITORING: DATE: 4/12/01 17 BOTTOM OF HOLE S L 0 P E .e e0 OF A� S* P491"- i...u.... ....... t"'. ...: # •P *.MICHAEL E. ANDERSON �; r CE.4381=o �,,s�f9Fn..• DEPTH OF WATER T TO DATE PE�gRINEDiSS1'Zi >2001 °%vvw.% a SITE PLAN READING DATE 0 NET TIME DEPTH OF WATER T TO 1.15 N a 1 1.25 10 LOT 3 10" J J V, v N 6 2 Q V 10 2- W Recharge READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 3 -April 1.15 12- 1 1.25 10 2- 10" Recharge 12- 2 1.3S 10 2- 10" Recharge 12- 3 1 1.45 1 10 2' 1 10- PERC RATE: I MIN./INCH PERC. HOLE DIAMETER: 6' TEST RLN BETWEEN--L.5—FT. AND5.5 T. COMMENTS: TEST HOLE PRESOAKED PRIOR TO TEST. TEST PERFORMED BY: T.L. KIMBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 4-17--01 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 3, FASSLER SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 gallon septic tank at the location shown on the site plan. Work also includes the construction of a new 32' long X 3' wide X 6' effective depth absorption trench at the location shown. The distribution line in the trench will be placed at 3' below the existing ground surface. Total depth of the trench will be 9' below the existing ground surface. All components of the septic system must be placed a minimum of 10' from the water service line on the lot. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. -Lot 3, Fassler Subdivision April 12, 2001 Page 2 of 3 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class 'C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). - Lot 3, Fassler Subdivision April 12, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Permit Number: SWO10167 Legal Description: FASSLER SUBDIVISION LOT 3 Date Issued: Jun 06, 2001 Expiration Date: Jun 06, 2002 Parcel ID: 051-531-34 Design Engineer: 0014 Anderson Engineering Site Address: NHN FASSLER CIRCLE Owner Name: MM & M CONTRACTING Lot Size: 29639 S0. FT. Owner Address: PO BOX 995657 Total Bedrooms: 3 Permit Bedrooms: 3 CHUGIAK . AK 99567 - This permit is for the construction of: Disposal Field ❑ Septic Tank _ Holding Tank Privy Private Well F] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 7. �(—Q/ DELL ORILIP)? b✓)9A/TSTO/_fOv,6 wELL TO XafA77-( PROPFIPTY L WE 100' 7-0 714e E )`-ST of PERM 17'e 0 c, -FC [ 5'/7-4. 9 Received By: Issued By: 74J. -L LQ'j' Date: c -7-11i Date: 6—IC-0/ Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-531.34 Permit Number SW O /O /6 % Property owner(s) MM&M Contracting Day phone 688.1236 Mailing address (1) P.O. Box 670495 Chuoiak, AK 99567 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) _Lot 3, Fassler Subdivision Legal description (Section, Township & Range) Lot Size 21639 Acre Sq.Ft THIS APPLICATION IS FOR: Number of Bedrooms Three (3) Sewer Only ❑ Well Only ED Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit FeesA iD0 Waiver Fees: Date of Payment b°yaq a dt Date of Payment: Receipt Number: Receipt Number. (Rev.12*0) Unsubdivided (Vacant) THIS PROJECT Dx.u• s.oc &A . vZ o L�1-0— � / � � Mme• 5 .. M1'�- � � � M'37' ► 1 Gy •c o sY secs+ FAS a.•.o L_ se -s .. �o C� +, � — z�.xuT p 00 ,. j Ile ^I O p i J -a+ •q • .. � —_—__—__ n 60.!!! //•e7.e2 777-33 ss7.L7 MEADOW RIDGE' ��y�.�'n usr/ soe (7z -ns) _ 1Rb5_ — •—?0' 33 AREA MAP SCALE 1" =100': • Municipality of Anc On -Site Water and Wastewater (907) 343-7904 Certificate of On -Site Systems Parcel I.D. 051-531-34 1. GENERAL INFORMATION Complete legal description Fassler, Lot 3 N g 0 2016 Expiration Date: I 1 "s '1 b Location (site address) 24847 Fassler Circle Chugiak, AK 99567 Current Property owner(s) Josh Henthorne Day phone _ Mailing address Real Estate Agent 24847 Fassler Circle Chugiak, AK 99567 Becky Powell 2. TYPE OF DWELLING: ix Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Three Day phone 244-5881 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well El Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance Received by: (�Pd�(',a, i'h / '�/12Pi Date:? COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ r.Z 6 ' oy Waiver Fee $ Date of Payment G —30 - (�� Date of Payment Receipt Number 6 t Receipt Number. COSA# QSC!(oil27-/ Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE Date 6/30/2016 °�F.....Al I F, 491"`� System #1 Approved for bedrooms p:;�, eM15 ANDERSON y •. System #2 Approved for bedrooms 4®®T�9Fo -a $ Disapproved 0���a ®��,'° Conditional approval for bedrooms, with the following stipulations: Original Certificate Date: g - The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer. registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS:. COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSAbluesheeLE' ., c If more than 1 septic system is on the lot: COSA Checklist # Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: FaSSIer, Lot 3 A. WELL DATA Parcel ID: 051-531-34 Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y Date completed 7/18/01 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 200 ft. Cased to 161 ft. Casing height (above ground) >12 in. FROM WELL LOG AT INSPECTION Date of test 7/18/01 6/3/2016 Static water level Well production 147 2 ft. 156 ft. g.p.m. 2.25 g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate 8.02 mg/L Arsenic ND ug/L Date of sample: 6/16/16 collected by: And. Engineering B. SEPTIC/HOLDING TANK DATA TankType/Material Septic/Steel Date installed 8/11/01-1/19/02 Tank size 1,000 gal. Number of Compartments 2 Cleanouts (Y/N) , Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 1/2016 Pumper One Stop Pumping C. ABSORPTION FIELD DATA Date installed 1/19/02 Soil rating (g.p.d./ft2 or fe/bdrm) 1.2 GPD/SF System type Deep Trench Length 39 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth 9'25 ft. Eff. absorption area 468 fe Monitoring tube Y Depression over field N Date of adequacy test 10/5/15 Results (Pass/Fail) PAS�Sv/ For 3 bedrooms Fluid depth in absorption field before test 0 in. Water adde �" ✓a New depth 2 in. Elapsed Time: 20 min. Final fluid depth 0 in. Absorption rate >= 450 g.p.d. Any rejuvenation treatment (past 12 mo,) (Y/N & type) N If yes, give date D. LIFT STATION Date installed "Pump on" level at Size in gallons _ in. "Pump off' level at Datum Cycles tested E: SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main >75' Sewer /septic service line >25' >50' Manhole/Access (Y/N) _ in. High water alarm level at Meets alarm & circuit requirements? On adjacent lots >100, On adjacent lots >100, Public sewer manhole/cleanout >100, Holding tank >75' Animal containment areas Manurelanimal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO Building foundation >51 Property line >5 Absorption field >51 Water main 10' Water service line >10, Surface water 100' > Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10, Building foundation >10, Water Service line > Surface water >100 Curtain drain None Noted Wells on adjacent lots >100, F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Withael E. Anderson, P.E. Date 6/34/201 COSA brown sheet 10-10-12.doc Water main >10' Driveway, parking/vehicle storage >10' MICHAEL E. ANDERSON CE -4381 ._ in. Municipality of Anchorage Development Services Department =: x3,t2.; Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # OSC161271 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 3 of Fassler subdivision. This inspection revealed a nitrate concentration of 8.02 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical' methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test', and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Municipality of Anchorage On -Site Water & Wastewater Program (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I. D. 051-531-34 Expiration Date: 7- -1-3 1. GENERAL INFORMATION Complete legal description FASSLER LOT 3 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 24847 FASSLER *CHUGIAK, AK 99567 KYLE & DANA PATTERSON Day phone 24847 FASSLER *CHUGIAK. AK 99567 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: Day phone 441-1334 TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site E Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ Received by Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 9610 Date of Payment y I Receipt Number oq I j n a COSA# C�6L13 IU 14 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 : ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E Engineer's Comments: In conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational rife of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE _ Z System #1 Approved for 3 bedrooms. System #2 Approved for Disapproved. Conditional approval for L2 bedrooms. bedrooms, with the following 337-6179 Date 3 /3 OF owsiTE WATER AND Original Certificate Date: q — — 13 The<M"udeXl/ ,a, chorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon th rep a stations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev. 1110.5) V If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: FASSLER LOT 3 Parcel ID: 051-531-34 A. WELL DATA Well type PRIVATE If A, B. or C provide PWSID# N/A Date completed 7/18/01 Sanitary seal (Y/N) YES Total depth 200 ft. Cased to 161 ft. FROM WELL LOG Date of test 7/18/01 Static water level 147 ft. Well production 2 g.p.m. WATER SAMPLE RESULTS Coliform U colonies/100 ml. Arsenic:L ug./L. B. SEPTIC/HOLDING TANK DATA Nitrate t• 1 a mg./L. Date of sample: 3/19/13 Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 12+ in. AT INSPECTION 3/19/13 WEI II =3 Collected by: GEG. Ltd. Tank Type/Material SEPTIC/STEEL Date installed 8/11/01-1/19/02 Tank size 1000 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping (016/2014 2012 Pumper Sf►N1-9'*" D0MPz<J"' C. ABSORPTION FIELD DATA Date installed;/>>/Ot-i/i9/o2 Soil rating (g.p.d./ftor � 1.2 System type TRENCH Length 39 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth *9.25 ft. Eff. absorption area 468 ft2 Monitoring tube YES Depression over field NO Date of adequacy test **3/19/13 Results (Pass/Fail) PASS For E bedrooms Fluid depth in absorption field before test E in. Water added 2475gal. New depth 6 in. Elapsed Time: E min. Final fluid depth 0 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date - **PRE-SOAKED WITH 2000 GALLONS OF WATER ON SAME DAY PRIOR TO START OF TEST. D. LIFT STATION Date installed Size in gallons Manhole/Access (YM "Pump on" level at in. "Pump oft" level ' . High water alarm level at Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankfiift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Sewer /septic service line 25'+ Public sewer manhole/cleanout N/A Holding tank Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehic a storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S I certify that i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineer's Printe Name JEFFREY A. GARNESS Date /,13 /j? (Rev. »ros) Municipality of Anchorage Community Development Department p `_ Development Services Division < On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 131114 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 3 of Fassler subdivision. This inspection revealed a nitrate concentration of 7.1 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEM: FOR A SINGLE FAMILY DWELLING Parcel I.D. y5I •-*I-3q COSA# 014-056 1. GENERAL INFORMATION Expiration Date: / d - / S - b? Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address FASSLER SUBDIVISION, LOT 3 24847 FASSLER CIRCLE * CHUGAIK. AK 99567 ADAM SEAHOLM Day phone 748-1115 24847 FASSLER CIRCLE * CHUGAIK. AK 99567 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage (les and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system In accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identif able features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to moot the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole bonefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will H confer any legal fight whatsoever. S. DSD SIGNATURE `' Approved for bedrooms. Disapproved. 337-6179 Date :7 113/07- ........ 13 07- . . ...... .......... J f rnessr ' E-7953 a ••�Ij3/�� �_�Apdo 40OdPr0 /efs10(�jjfttl ( (ft Conditional approval for bedrooms, with the filowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Other ONSITE WATER AND •: WASTEWATER PROGRAM ••. BY: Original Certificate Date: 7-19—M (RW 71N5( Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragew Street P.O. Boz 198050 Anchorage, AK 99519-6850 www.murJ.org/o=W (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: FASSLER SUBDMSION, LOT 3 Parcel ID: OS1 - S --J 31 -.3 Ll- A- WELL DATA Well type PRIVATE If A. B, or C provide PWSID# N A Date completed 7/18/2001 Sanitary seal (YIN) YES Total depth 200 ft. Cased to 161 ft. FROM WELL LOG Date of test 7/18/2001 Static water level 147 ft. Well production 2 g.p.m. WATER SAMPLE RESULTS: Coliform (k colonies/100 ml. Nitrate*• le mgJL. Well Log (YIN) YES Wires property protected (YIN) YES Casing height (above ground) 18+ in. AT INSPECTION 6/26/2007 153 ft. 1.65+ g,p,m, Other bacteria 6 colonies/100 mi. Arsenic: NO ug./L. Date of sample: 6/25/2007 Collected by: GEG Ltd. B. SEPTIC/HOLDINO TANK DATA Tank Type/Material STEEL Date installed 8/11-25/2001 Tank size 1000 gal. Number of Compartments 2 Cleanouts (YIN) YES Foundation cieanout (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) N/A Date of pumping 6/28/2007 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA Date installed 5/1 1-29/20001 Soil rating .p.d. ft'/bdnn) 1_2 System type TRENCH Length 39 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth +9.41 ft. Eft. absorption area 468 fe Monitoring tube YES Depression over field NO Date of adequacy test 6/26/2007 Results (Pass/Fall) PASS For 3 bedrooms Fluid depth in absorption field before testD8' in. Water added 480 gal. New depth DRY in. Elapsed Time: 0 min. Final fluid depth DRY in. Absorption rate >= 450+ g,p,d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date D. UFT STATION Date installed "Pump on" level at —in. Datum E. SEPARATION DISTANCES Size in gallons Manhole/Access (YIN) "Pump ofr High water alarm level at in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankfliR station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parkingivehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's PrintedName JEFFREY A. GARNESS . Date 7: 1316-1 COSA Fee $ L-16 0. U U Date of Payment Receipt Number —^5 (� % C� //►7A/ (Rw. 11105) Waiver Fee $ Date of Payment Receipt Number -\ Municipality of Anchorage • Development Services Department ' j Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsitc (907) 343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 070250 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Lot 3 of Fassler subdivision. This inspection revealed a nitrate concentration of 7.18 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. SOS RcE# 1072943001 Client Name Garness Engineering Group, Ltd. Project Name/p passlcr L3 Client Sample ID Fassier L3 Matrix Drinking Water PWSID 0 All Dates/times arc Alaska Standard Time PrintedDate/lime 07/11/2007 14:51 Collected Date/time 06/252007 18:45 Received Daterrime 06262007 10:15 Technical Director Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results PQL Units Mcthod Container ID Limits Date Date [nit Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 0627/07 07/09/07 TK Waters Department Total Nitmtc/Nitritc-N 7.18 0.100 mg/L 511204500NO3-P D (<10) 07/03/07 1DS Microbiology Laboratory Total Coliform 0 coVIOOmL S%120 9222B A (<I) 0626/07 DLC 07/13/2007 11:05 9073449821 i■ man JRs Painping PO Box 773415 Eagle River, AK 99577 (907) 694-6454 1pilling information Adam Seaholm 24847 Fassler Circle Chugiak, AK 99567 (907) 68&2581 ob Site Information Adam 24847 Fassler Circle Chugiak, AK 99567 (907)688-2581 JRS SEPTIC Job Desatpaen: 1 DOOG P.O. Number: Terms: Below": Map Book: Crose Strews: Job Comments: Net 30 Karlia Homestead Road PAGE 01 Service Agreement Number: 023344 Order Date: 25 -Jun -2007 Service Date: 28 -Jun -2007 12:00 Technician: Dan Ta(%: 0 Job Type' New Map Grid: 24 tank and checked field Additlonal Location Comments Disgram: St0Ltarem2=3A4 bm0 Gallons Planned: 1000 ws on gray home w/ maroon -red trim. Gal. Actual: Hose Length: 2 Double Tank: O Pump System: 95 Baffles Inlet: ❑ Baffles Outlet: O Iaea :a Service Type Qty Price Each Tax? Extension Actual Septic Service 15K 1 $135.00 No $135.00 NonTaxable Total Taxable Total Tac Total Grand Total Estlnlaled Charges: $135.00 $0.00 $0.00 $135.00 Actual Charges: �� r Customer agrees to the terms and condiecns shown. THIS IS A BINDING AGREEMENT. Signature and Title of Customer Reproeenlatlw Accepted by JRs Pumping Date Date Accepted For your added convenience we accept American E)Preaa, Dicover, Visa and Mastw Card payments over the Phone. Aver 30 Days account will be turned over 10 COLLECTIONS. $30.00 Fa NS F Checks Returned. Municipality of Anchorage -� Development Services Department Building Safety Division ' On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 _ www.ci.anchorage.ak.us /d/1 X)4/t/-r (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051- 531- 34 HAA# Expiration Date:^ 1. GENERAL INFORMATION Complete legal description LE 3 F4ssl..,. SID Location(site,addrirssordirections) '2494_f &5s It... Circle.. 4 Current Property owner(s) -r.-, LyJot, Day phone (089 - O0b9 Mailing address Lending agency Mailing address 2yg47 FQsslt, G-cic Day phone Real Estate Agent Ton (ilk¢ Day phone 632-OS13 Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS:_ 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Weil 19 Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm SPURKLANO CMGuJE6R%N& Phone 2i9.391fo Address '701 w istl` Ave S,,:k.- 203 ,,+ Engineer's Printed Name `i'0956 Al SPyQK LANG Date 1u2-4' 2004 5. DSD SIGNATURE Approved for 3 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Note: The well for this property meets existing State and Municipal Codes. There are nitrates present. It is suggested that periodic testing be performed to Insure the wells continued suitabilih Current nitrate concentration Is 5.65 mg/I. EPA maximum concentration is 10.0 mg/l. More informs on on nitrates Is available from the On -Site Services Program, at 343-7904. Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date: (Rev. 01102) r.. Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343.7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Foss ler Lt .3 Parcel ID: 051- 53/- 3Y A. WELL DATA Well type tori 9 -Aft Date completed A7, 2001 If A, B. or C provide PWSID # = Sanitary seal (YIN) y Total depth iQ_ft. Cased to 151_ft. FROM WELL LOG Date of test -�) 16 1 200 1 Static water level 117- ft. Well production Z g.p.m. Well Log (YIN) i/ Wires properly protected (YIN) y Casing height (above ground) 2Qo in. AT INSPECTION 2 -111 2004 154 : ft. I.9 g.p.m. WATER SAMPLE RESULTS: Coliform--0--colonies/100 ml. Nitrate S•b mg./I. Other bacteria _colonies/100 mi. Arsenic: mg./I. Date of sample: IZ 2J 04 y Collected by: Lars Spma do l B. SEPTIC/HOLDING TANK DATA Tank Type/Material S heel Date installed 8')+f U01 Tank size Io0 0 gal. Number of Compartments Cleanouts (YIN) Y Foundation cleanout (YIN) L Depression over lank (YIN) A/ 'High water alarm (YIN) A/ Date of pumping V41 -0 `1 Pumper SO C. ABSORPTION FIELD DATA Dateinstalled S1111120ol Soil rating (g.p.d.lftZ or ft2/bdrm) I_Z System type Do cp Trtnt-� Length 39 ft. Width 3 ft. Gravel below pipe (0 ft. Total depth 10 ft. Eff. absorption area y�_fta Monitoring tube Depression over field !� Dale of adequacy test 12 Zt 2004 Results (Pass/Fail) P -M, For __3 bedrooms Fluid depth in absorption field before test 11 in. Water added1-10 gal. New depth I in. Elapsed Time: 0 min. Final fluid depth L in. Absorption rate >= 99C) g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) A/o If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) 'Pump on' level _ in. 'Pump off" level _ in. High water alarm level in. Datum Cycles to Meets alarm & ' uit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot i 100' On adjacent lots i 1100' Absorption field on lot � 10V On adjacent lots i /00' Public sewer main N/A Public sewer manhole/cleanout N� Sewer /septic service line 'r 25 Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 112. Water main Wells on adjacent lots )/00' Property line '? 10' Absorption field 7 5 ' o Water service line 710' Surface water /V SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line %/D' Building foundation 32' Water main N�A Water Service line i f0 Surface water N. 0. Driveway, parking/vehicle storage /o' Curtain drain N 0 • Wells on adjacent lots 7100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records. that the above systems are in conformance with MOA HAA guidelines in effec1 on ihis date. 1p"" �(//�j Engineer's Printed Name l nlobQ H SoL r 1�1hN[� Cita° Date HAA Fee 5 L 3� 3 0 Waiver Fee $ Date of Payment /!� / g' O ., Date of Payment Receipt Number .2, 9� Receipt Number (Rev. 12/01) e/ 12-23-03 12:0411 FRC4-CT1E ESI, SCS ENV SERVICES SCS RcEN 1048195001 Client Name Tohhen Spurkland P.E. Project Name/# Fa:slen. Lot 3 Client Sample 10 Fasslen. Lot 3 h1strix Drinking Water Sample Ranarks: ICT5515301 T-355 P.WGS F-TH All Dates?Imef are Alaska Standard Time Printed Date/Time 12/28/2014 13.25 Collected Dalt/Time 12212003 14:30 Received Dalerlime 122120d{7:30 Technical Director _,Stephen r de Released By It n.11s --- PQL Valla Metnd Commna lD AnowaWe Prep Aadysia Intt Pnameut Liroin Dace Dau watara• Department Nitrme N 5.65 0.100 Microbiology Laboratory Total Coliform . TNLC OB m;4 EPA 300D B (<-10) 1222/03 81A ccl/100m1 Sts12092226 A (<-1) 12.21.93 DKC Tobben SDurkland Tobben SDurkland P.E. 203 W 15th #203 Anchorase. AK 99501 Work Order: 1048052 Alpine Terrace Lt 2 B 3 Client: Tobben Spurkland P.E. Report Date: December 22, 2004 Enclosed arc the analytical results associated with the above workordcr. Laboratory Analysis Report 200 W. Potter Drive Anchorage, AK 99518-1605 Tel: (907) 562-2343 Fax: (907)561.5301 Web: http://%%ivw.sgscnvironmental.com As required by the state of Alaska and the USEPA, a formal Quality Assurance/Quality Control Program is maintained by SGS. A copy of our Quality Control Manual that outlines this program is available at your request. The laboratory ADEC certification numbers arc AK08-03 (DW), UST -005 (CS) and AK00971 (Micro). Except as specifically noted, all statements and data in this report arc in conformance to the provisions set forth by the SGS Quality Assurance Program Plan and the National Environmental Laboratory Accreditation Conference. If you have any questions regarding this report or if we can be of any other assistance, please call your SGS Project Manager a (907) 562-2343. The following descriptors may be found on your report which will serve to further qualify the data. PQL Practical Quantitation Limit (reporting limit). U Indicates the analytc was analyzed for but not detected. F Indicates an estimated value that falls below PQL, but is greater than the MDL. J The quantitation is an estimation. 4 Indicates the analyte is found in a blank associated with the sample. • The analyte has exceeded allowable regulatory or control limits. GT GrcatcrThan D The analyte concentration is the result of a dilution. LT Less Than ! Surrogate out of control limits. Q QC parameter out of acceptance range. M A matrix effect was present. JL The analytc was positively identified, but the quantitation is a low estimation. E The analyte result is high outside of calibrated range. Note: Soil samples arc reported on a dry weight basis unless otherwise specified SGS Environmental Services Inc. _ 1200 W. Potter Dr, Anchorage AK. 99518.1605 t (907) 562-2343 f (907) 561-5301 %mw.us.sgs.eom -SG$- SGS/CT&E ENVIRONMENTAL SERVICES Drinking Water Analysis Report for Total Coliform Bacteria READ e15TRUCT*W ON REVERSE GIDE BEFORE COLLECTING !AMPLE MUST BE COMPLETED BY WATER SUPPLIER 13 PM-"IC WATER SYSTEM IW F&FUVATE WATER SYSTEM 77 Q Sww R"uft ❑ Sww brvcua 13 Sand Raaub 200 W. POTTER DRIVE ANCHORAGE, ALASKA 99518 Tet: 907582-2343 Fax: 9075815301 Lob RN No. 1050235'V�- 111111111111 13 Send enoloa SAMPLE COLLECTION: •..r wwr. wy+�+ ..w nwr•wr r.r Dae.: Fb1 IV 12 200S er+ 0•r r.w Tl. : . 11.=A r Q1 PM 0 ..) Loca&w LE ?, rnSS1G� SAMPLE TYPE: Tmmporbd �,J_l to Lab By: fame as Collector Other. TO BE COMPLETTED BY LABORATORY o❑ Routine 13 Treated Water Y^Repeat Sample A<ntreatad Water (refer to tab no. ► ❑ Special Purpose Sample Recelvina: Date: �� / 2 CSS ❑ Sw" e 30 h0•+01d; ❑ RUSH SAMPLE Rnuae maybe va•liabla Tune: Itro Temp: ❑ 4e Nou Wakw Phone N: Delivery Me9wd: r For Locow" Fax Received By: Comm•wa ........................................................................................................................................... Bacteriological Water Anatole Record: Sent b ADEC urAowlo (PIA) REaOIYa: ANC FSK JUN AmyslalWW^� 1 �it J Total coworm - WtdTinr� Amhati E. Coo Sard b cNe t Amylkal McOwd: MEMBRANE FRYER RESULTS: Phoned 'Q faxed Q Dycl Count CabnbW00mL DaWnWw:_,��. Membrane Fitter vwnuaon S VAV'' ❑ MMO-MUG (PIA) Satisfactory { EC: ❑ Unsatisfactory ...�.. Reported By: DateMme: II14Ia�� avwr• (Yi Trre•r»la•r.»rf:w a•ew.e.+rw Form f FW 0053 17/17/03 .. o. - Jv A/ I Asa. ks�D" ✓ AS -BUILT F>fJl.r tt'Ei�e �T f...e-. w. Ern�-• ... C -MIA 1 hereby certify that I have surveyed the following described t, property: Lnr 3 II EV r -f F..•iio..2. TIS"lJ,KrWSr'r,.... ..... .x+,11.�� r or- At�t'ei> Anchorathat ve- ments situated hereon are within the prorid lines don :.'.�."� f>•'" •`ty`S.� dq y and t overlap or encroach on the property ly 1g property thereto, that `•yy - �'t` f „y y 1 k .�� 's no Improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways; * '�49 th� J"- - - transmission lines or other visible easements on said property. r �� except as indicated hereon. . ie `'ate Dated at Eagle River, Alaska ff s�! a d ` Ho..NUCion : J - 3 this &Y u.n..c2001 360- e �•., a:� `•,� 4 `• > • , t +�+ ROBERT C. JOHNSON SCALE: Registered Land Surveyor No 880-L5 4 j •• «✓ �' ., y o Box 77-0456, Eagle River, Alaska 99577 . �1'�'ai.%%, •o-' - Phone (907) 6942543 .. r ` Municipalityof AncHorage;; Development Services Department r Building Safety Division •,- { , On Site Water and,Wastewater Program ,, C„ ,,, < , P.O. Box 196650:Anchorage`AK.99519-6650 e • ., www.ct.anchorage;ak.us,', (907)343-7904 r> CERTIFICATE'OF-HEALTH AUTHORITY ;PPROVAL� ' f FORA'SINGLE FAMILY DWELLING' cy` Parcel I D 051-531-34 HAA# «-� J. p. , , Expiration Date: Z 1. GENERAL INFORMATION ^. Complete legal description Ar, Lot 3,FasslerSubdivision Location site address or ilirections Monron Street and Fassler Circle*,,J Current Property owner(s)MMBM Construction Day phone 1688.1236 is Mailing address , • P.O. Box 670495 Chugiak, AK 99567. " Lending agency Day phorie Mailing address,;... ' f Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER Three Three 3 .BE - 3. ;.TYPE OFrWATER SUPPLY:: ,TYPE OF WASTEWATER DISPOSAL , In Well ® Individual On-site Individual Water Storage - ❑ -Individual Holding tank' ❑ r_-ommunit Class`+ Well __ y ❑ t Community.On site ' ❑ i Public Water System' ❑ Public Sewer Q The Municipality of Anchorage Development Services Department (DSD) Issues Cert�cate's`of Heaitti Authority Approval (HAA) based,only upon;the representations given in paragraph 5 by an independent:professional civl engineer registered iii the State of Alaska. Certificates of Health Authority Approval are required for -M' transfer of title (except between spouses) for, properties senied by a single family.on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are. ` valid for 90 days from the date of issue for properties served by a private orClass C well and may be ressued with ' new water sample results less than 30 days old: (Certificates may be reissued for a period of up to one year with ` ... valid water samples.) �Cert�cates_'are. `valid for one year for properties served by Class A w B 'well s'or a •public:= water system. The Municipality of Anchorage is not responsible.for errors or omissions in, the, professional -„ engineer's work' . „ . 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affi; hereto and as'of the validation' date shown below, I verify that my investigation;',' based on'procedures'ou0ined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are') safe, functional and adequate for the numberpf bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the . Municipality of Anchorage files:and from my investigation and inspection, the on-site water supplyiandlor wastewater disposal system'is(are) in compliance with'aII applicable Municipal and Stale codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 •Address P.O.Box 240773'Anchoraae, AK 99524 i Engineer's Printed Name, Michael E.`Anderson, P.E. Date 1120102 f to •rf s��r, 49 TONNliZ E r,.... ...... ..: .. ..' R, , P f : MICHAEL E. AERSON O,i' CE -43811 NV. y`vi 5. DSD SIGNATURE p�Of��F , • ; ��vpm 3 . bedrooms. _ 444 4t�o�^ao oo•° :; Approved for i o Disapproved.,. t Conditional approval for bedrooms, with the following stipulations:. . Municipality of Anchorage ' Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 9951846650 www.ci.androrage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 3. Fasster Subdivision Parcel ID: 051331.34 A. WELL DATA Well type rte Date completed TnWM1 Total depth 200 ft. If A, B, or C provide PWSID # Sanitary seal (YIN) I FROM WELL LOG Date of test 71`1812001 Static water level 147 ft. . Well production 2 g.p.m. WATER SAMPLE RESULTS: Well Log (YAV) Wires properly protected (YIN) Y Casing height (above ground) >24 in. AT INSPECTION ft. Collars —L—colonies/100 mi. Nitrate 4.67 mg.A. Other bacteria 0 colonies/1W ml. Date of sample: iD211=1 Collected by: T.10mbmuph S. SEPTICIHOLDING TANK DATA Tanis TypefMateriat SeotidSteel Tank size 1.000 gal. Number of Compartments a Foundation deanout (YAd) Y Depression over tank (YIN) N Date installed 111`111= Cleancuts (YIN) Y High water alarm (YIN) N Date of pumping Pumper NowConsWction C. ABSORPTION FIELD DATA Date installed Bn112001 Soo rating (g.p.d.AP or ftAbdrn)12 GPDISF System type Deep Trench Length 39 ft. Width 1 ft. Gravel below pipe 6 ft. Total depth 10 ft. Eff. absorption area 468 fl Monitoring tube Y Depression over field N Date of adequacy test Results (PosslFail) For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: —min. Final fluid depth _ in. Absorption rate k g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date 0. LIFT STATION Date installed 'Pump on' level at _ in. Datum E. SEPARATION DISTANCES Size in gallons 'Pump otP level at _ in. Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lt@ station on lot 1100' Absorption field on lot >100' Public sewer main WA Sewer /septic service line >25' Manhole/Access (YM) High water alarm level at in. Meets alamr b davit requirements? On adjacent lots >IW On adjacent lots >1W Public sewer manhole%Jeancut WA Holding tank WA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Budding foundation >8 Property line� T Absorption field >S Water main WA Water service tine 110' Surface water MW Weds on adjacent lots >1W SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >17 Water Service line >I(r Surface water >100' Driveway. pargngtvehicte storage >10' Curtain drain None Noted Weds on adjacent lots 3,1110' F. COMMENTS G. ENGINEER'S CERTIFICATION I cer* that I have determined through field inspectlons and review of Munklpaf records that the above systems are in conformance with MOA HAA guidelines in effect on dile date. Engineer's Printed Name Michael E Anderson, RE 9 HAA Fee Date of Payment +3`75' /-ZZ-o Waiver Fee S Date of Payment Receipt Number l µL 94 Receipt Number (Rev. t?roo) ar V- X e.f�.....a....... A....'.� ... �i•,SSI\�r5ai� ��w.� JAN -03-02 03:05PM FROM -ME ENVIRONWNTAL SRV CT&E Environmental Services Inc. 9075615301 T-392 P.02/03 F-504 CME RcL# 1018674001 Client PON Client Name rson Engineering Printed Datenime 01/03/2002 9:00 Project Name/# Lo /Fassler Subd Hose Dtb Collected Datdrlme 12/28/2001 13:30 Client Sample ID Lot 7Fassler Subd Hose Bib Received Date/time 12/26/2001 14:25 512tria Drinfing Water Technical Director Stephen C. Ede Ordered By PWSID 0 Cor 3 GASsu� Released Oy Sample Remarks Parameter Resale Allowable Prep Analysis PQL Units Method Limits Date Date [nit Waters Department Nitrate•N 4.87 Microbiology Laboratory Total Coliform 0 0 n 4 Received Time Jan. 3. 3:01PN 0.200 m8/L EPA 300.0 (<10) 12/28/01 SCL coU100mL SM1892220 (<1) 1228/01 KAP JAN -03-02 03:05PU .jZ11� FROLKTIE ENVIRONIENTAL SRV 9075615301 T-392 P.03/03 F-504 ME Environmental Services Inc. Laboratory Division 200 W. Potter Drive DrinkingWater Analysis Report for Total Coliform Bacteria Anchorage, AK 99518.1605 Y P Tet 19071562.2343 READ INSTRUCTIONS ON REVERSE SIDE BEFORE COLLECTING SAMPLE Fax: (°07) 561.5301 MUST BE COMPLETED BY WATER SUPPLIER I TO BE COMPLETED BY LABORATORY ❑ PUBLIC WATER SYSTEM I.D. N ,d PRIVATE WATER SYSTEM ❑ Send Resaht ❑ Sendfneoice o 4 FAStii-PyLl 1-3 0, W. wa n.n. ,>u.YY au.r.YY. FW. N.r Y• N. ( y W SsndRerahr O Stndinroice a{.YW AY•.a C" R c^ SAMPLE DATE: Month Day Year An lysis shows this Water SAMPLE to be: Satisfactory ❑ Unsatisfactory ❑ Sample over 30 hours old, results may be unreliable Cl Sample too long in transit; sample should not be over 49 hotl-s old at examination to indicate reliable results. Please send new sample via special deliveryil. Date Received 27 Time Received 1qp Analysis Began \, l,v Analytical Method: Membrane Filter t2D MMO-MUG • Numberofcolonies/100m1. Result* Analyst 1018574 SAMPLE TYPE: .4u' Routine a Treated Water o Repeat Sample (for routine sample D Untreated Watts with lab ref. no. ) ❑ Special Purpose 'time Collected SAMPLE LOCATION Collected By /33x30 is /iigi3 ' rkue Prim Comments: �I 6 Date: LTJ .ach Fbks Jun ❑ Fazed Time: Client notified or unsatisfactory results: Phoned Date: BACTERIOLOGICAL WATER ANALYSIS RECORD Spoke with Time: MMO-MUG Result: Total Coliform E Ceti Membrane Filter: Direct Count �/ Coloniestt00ml Verification: LTB BGB COLIFIRM Fecal Coliform Confirmation _ Final Membrane Filter Results _ 0 Coliform/100 ml Reported By '— Date 17-ZCj Time /5-30 hrs •v BM Member of the SGS Group (Societe Generale de Surveillance) TNW- rw NY.m.I re C.Y" oa-a...a:(Ime ENVIRONMENTAL Received TImer-Jan • LIN 3:0jPWIA. ILLINOIS. MARYLAND. MICHIGAN. MISSOURI. NEW JERSEY. OHIO. WEST VIRGINIA SITE PLAN SCALE -1"=4W ' W J N Q