Community Development Department Page 1 of 3
On -Site Water & Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP151387
PID Number: 051-541-12 ❑ New ■Upgrade
Name: TROY LOWDERMILK
ABSORPTION FIELD
❑ Deep Trench ■ Shallow Trench ❑ Bed ❑ Mound
Address:
24947 MALCOME DRIVE *CHUGIAK,
AK 99567
❑ Other
Phone:
No. of Bedrooms:
Soil Rating:
Total Depth from original grade:
(907) 748-0156
3
1.2 GPD/Sq. Ft.
6 Ft.
LEGAL DESCRIPTION
Depth to pipe imart from original grade:
Gravel depth beneath pipe:
SEE DWG. Ft.
2 Ft.
Subdivision:
Block: Lot:
FlII added above original grade:
Gravel length:
PETERS GATE
2 4
SEE DWG.
30
Ft.
Fl.
Owns ip: anger
— —
ec ton:
—
Gravel width:
Beds Number of lines:
Distance between lines:
5 Ft.
—
it.
SEPARATION DISTANCES
Total absorption area,
214
amber of trenches:
1
Dist. between trenches:
—
To
Septic
Absorption
Lift
Holding
Public/Private
From
Tank
Field
Station
Tank
Sewer Lines
Sq. Ft
Ft.
Well
100'+
100'+
—
—
25'+
TANK ■Septic ❑S.T.E.P. ❑Holdin ❑Other
Manufacturer.
capacity:
Surface Water
100'+
1DO,+
—
—
ANCHORAGE TANK
1000
cal.
Lot Line
5'+
,o'+
-
-
N/A
Material:
Number of compartments:
STEEL
2
LIFT STATION
Foundation
5'+
10'+
—
—
Curtain Drain
NONE KNOWN
Manufacturer Iy:
cal.
'Pump on' level at:
'pump off I
High water alarm at:
Remarks: *SEE PERMIT REGARDING SEPARATION TO GLACIATION.
THIS IS A 1.5 BEDROOM UPGRADE TO CONVERT TO A 3Pump
Make &
Electrical inspections performed by:
BEDROOM SYSTEM.
PIPE MATERIAL
OLD TANK DECOMMISSIONED PER UPC
House to tank EXISTING Tank to D3034
drainfield
Installer ARM SERVICES,
LLC
Drainfield D3034 CO/MT D3034
Inspector GEG, Ltd.
BENCH MARK (Assumed elevation)
100.00 n,
Inspection
Location and Dewrlption:
Dates: 1st 12/11/2015 2nd
1/22/2016
3rd 1/22/2016 4th
BOTTOM OF TRIM AT FCO
ENGINEER'S SE
Community Development Department Approval
oo�o
0 4
o OF 4p
Conditional approval:
Date:
........ . ..................
A. rn ss. -
s:E-79
E— 79�Q
�
s ,ce0
«
Approve i rn.� lr
Date: `�� '
e''•i.�.2�x EoAo
0� aprafessla�°o
Inspection Report _1-1-12.dac
PERMIT NUMBER: PARCEL ID NUMBER:
OSPI51387 L RECORD DRAWING / 051-541-12
Zab4� �� tvcfi�f tnSfa e / TK-Ltt 1v SPlli r
C,�5J �t�Wa4.f� �12�51 1'%O is a 11nS kgt Iz
A B �+
m
DRCHUNE WITH /
SURFACE WATER
/ DOUBLE
EXISTING
CLEWOUTS
2 BEDROOM
DRAINFlELD � I
EXISTING CULVERT
NEW 1000 GALLON
SEPTIC TANK
PATH IF GLACIATION
INTINUES
VE
140 — —
GARNESS ENGINEERING GROUP, Ltd
- CIVIL & ENVIRONMENTAL ENGINEERS
3701 E. TUDOR ROA. SURE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179 • FAX (907) 33B-3846 • WEBSITE: wxw.gameven9lnaedng.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
TROY LOWDERMILK 748-0156 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
PETERS GATE; BLOCK 2, LOT 4 J.L.M./L.K.B.
TYPE OF WORK: DATE:
�- RECORD DRAWING 1/25/2016
u
\
GARNESS ENGINEERING GROUP, Ltd
- CIVIL & ENVIRONMENTAL ENGINEERS
3701 E. TUDOR ROA. SURE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179 • FAX (907) 33B-3846 • WEBSITE: wxw.gameven9lnaedng.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
TROY LOWDERMILK 748-0156 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
PETERS GATE; BLOCK 2, LOT 4 J.L.M./L.K.B.
TYPE OF WORK: DATE:
�- RECORD DRAWING 1/25/2016
u
PERMIT NUMBER: PARCEL ID NUMBER:
OSP151387 RECORD DRAWING 051-541-12
TOP OF TANK -
AT INLET = 94.36
INVERT OF BUNG
AT INLET = 93.72
INSULATION 2" THICK PER CONTRACTOR
FINAL GRADE = 98.1-98.64
ST2
TOP OF TANK
AT OUTLET = 94.46
NEW 1000 GALLON II
SEPTIC TANK INVERT OF BUNG
AT OUTLET = 93.68
TH#1 ORIGINAL GRADE
AT HIGHEST
POINT = 92.10
BOTTOM OF
TRENCH = 86.1
MT CO FINAL GRADE _
92.28-93.42
rFILTER FABRIC
RELATIVE ELEVATION OF
BOTTOM OF TH#1 = 80.10
DRY ON 1/12/2016
GARNESS ENGINEERING GROUP, Ltd
M = CIVIL & ENVIRONMENTAL ENGINEERS
3701 E TUDOR ROOD, SUITE 101 a MCHORODE M 995M a PHONE (9077) 337-6179 a FM (907) SSB -3246 a WEB . w .gamomeWlnaMng.aam
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
TROY LOWDERMILK 748-0156 3 OF 3
LEGAL DESCRIPTION: DRAWN BY:
PETERS GATE; BLOCK 2, LOT 4 L.K.B.
TYPE OF WORK: DATE:
�, RECORD DRAWING 1/25/2016
On -Site Water and/or Wastewater System
Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151387 1'2,15 /Z1po
Tax Code Number: 05154112000
Work Type: SepticTank Upgrade
Permit Effective Dates: December 09, 2015 to December 08, 2016
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: PETERS GATE
Site Legal Address: PETERS GATE BLK 2 LT 4 G:1262
Owner/Address: LOWDERMILK TROY EDWARD
24947 MALCOM DR CHUGIAK AK 995670000
Site Mailing Address: 24947 MALCOLM DR, Chugiak Lot Size in Sq Ft: 54014
Total Bedrooms: -9-3
This permit is for the construction of:
'(-N- Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: — -
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By
Cat rye v ->es 4o btz ewtvt s.
By Date:
Date: d f
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program
Mayor Dan Sullivan
On -Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcell.D. Ci�t-S4t -I *
Property owner(s) I Vw A'-JCAfd %tt
Mailingaddress :�Lla YAcdcolw1 Ott-, Lyi
Site address S c.✓„ -'L
Legal description (Sub'd, Block & Lot) I -Pn
Legal description (Township, Section & Range)
Lot Size Sq.Ft.
Day
L
Number of Bedrooms _iFF-3
APPLICATION IS FOR:
APPLICATION IS AN:
(sithatapply)rption
Initial ❑
Field
Absorption Field
nLr�J,/
Upgrade IBJ/
Septic Tank
Renewal ❑
❑
Holding Tank
Privy
❑
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify
applicable Municipal codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: -oll-0
Date of Payment: Ic' I/S—
Receipt Number: 07 LdLl
Permit No. O -CRI s1.3 S zL
'� L't'd `
TYPE OF DEWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance: —
is in accordance with
b°360acti Fees:
Date of Payment: /41
Receipt Number: 7 rgj
�---
Ne—
(Rev. 01/11)
col
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
January 12, 2016
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Attention: Jay Crewdson, P.E.
Ref: Proposed Drainfield Upgrade for Peters Gate S/D; Block 2, Lot 4
Mr. Crewdson:
The existing house is served by a private well and septic system. The septic tank was
recently upgraded with a 1000 gallon septic tank and paperwork was submitted for a
COSA for a 2 bedroom house. A recent appraisal of the house showed that the house is
actually a 3 bedroom residence. Based upon the documentation of the septic system,
the new septic tank meets the size requirement for 3 bedrooms, but the drainfield does
not meet this sizing requirement. We are proposing that a 1-1/2 bedroom sized
drainfield be installed to meet the sizing requirement. We are proposing that after the
double cleanouts (after the new septic tank), a new flow splitter be installed so it evenly
splits the flow between the existing drainfield and the new drainfiled. Comments
regarding the design are summarized as follows:
1. SOILS: See the attached soils log which show the soil classifications, groundwater
monitoring, and the percolation test results. The new drainfield will be installed within
the 30 foot radius of this test hole.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: During our site visits to the property in October, there was no
surface waters within 100 feet of the existing septic system and there was no visible
standing water found on property. While excavating the test hole, we found glaciating
water coming from the ditchline to the west flowing on to the property. Per our
conversations with you, this glaciated water is not deemed to be a surface water. It was
your recommendation that a berm or Swale be installed between the new drainfield and
the glaciation so that in the event of a drainfield failure, daylighting effluent would have
to travel 100 feet (or more) before reaching the glaciated area. As can be seen on the
design drawing, we have shown a Swale with a note addressing this issue. Based on
our conversation with you, a surface water waiver is not required. We are also
recommending that the homeowner contact the MOA Right -of -Way Department to
3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.00m
CO1
Page 2 of 2
address the need for the ditchline to be cleaned -out. It is our opinion that if the ditchline
were cleaned out of debris and regraded, with possibly a dirt block at the property line,
glaciation would most likely not occur on property in the future.
4. TOPOGRAPHY: As can be seen on the attached design drawing, the average
topography around the proposed drainfield is 15-20%.
We are unaware of any adverse impacts this installation would have on adjacent wells
or septic systems. If you have any questions, please contact us at 337-6179. Thank
you for your assiAtance.
.E., M.S.
3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338.3246 * Website: www. garnessengineering.com
GARNESS ENGINEERING GROUP, Ltd Ad---dr—`5Y-`-
WEENOM CIVIL &ENVIRONMENTAL ENGINEERSommo
December 9. 2015
6'51-`Vl-12
Municipality of Anchorage 2l S— 12�q 15
Development Service Departmentu/ 6-7ya�{
On -Site Water & Wastewater Program 17.
4700 Elmore Road ► OSP lS j3��
Anchorage, AK 99507
Ref: Proposed Septic Tank Upgrade for Peters Gate S/D; Block 2, Lot 4
To whom it may concern:
The existing 2 bedroom house is served by a private well and septic system. The septic
system consists of a 1,000 gallon septic tank and deep trench type drainfield. We recently
tested the drainfield and it passed an adequacy test; however, we found that the tank had
leaks in it and is not retaining a normal liquid depth. We are proposing to decommission
the old 1,000 gallon septic tank and install a new 1,000 gallon septic tank. We request a
permit be issued to replace the tank.
We are unaware of any adverse impacts this installation would have on adjacent wells or
septic systems. If you have any questions, please contact us at 337-6179. Thank you
3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
I
LOT 8, BLOCK 1; I
PETERS GATE S/D
AlI
I
N I
i SCALE: `,
/
I
I
LOT 7, BLOCK 1;
PETERS GATE SID
------------
DITCHLINE WITH I
SURFACE WATER -G'
•\
I
DITCHL WITH I
LOT S, BLOCK yRFACE TER
PETERS GATE SID
---------- I
♦ I
♦J
♦ I ♦
I
I
I
LOT 2, BLOCK 2;
PETERS GATE SM
I
I
II---------------
NEW--------------
LOT 3, BLOCK 2; 1
PETERS GATE S/D ,
NEW 1000 GALLON
EXISTING
DRAINFIELD
PROPOSED
GLACIATION
I 1
LOT 7, BLOCK 2;
PETERS GATE SID I
I I
I
I
— — — — — — — — — — — — — —
I
1
I
LOT B, BLOCK 2; 4100'yyE
PETERS GATE SID
-EXISTING 100P,/
3 BEDROOM I IONS
HOUSE
1 I
1 I
LOT5,B1LOCK2;
`♦ PETERS GATE S/D I
♦ I
1 � I
DITCHLINE _
CULVERr—MALCOM DRIVE_'_---
----- — — —z-===
--------------
I I
I LOT 3, BLOCK 3; ` � I
" PETERS GATE S/D ``♦ U
i / I ♦ ♦Iltw
r I �
'---•--------- — — — —
/ LOT 4A, BLOCK 3; ♦11
PETERS GATE SID YI LOT8, BLOCK 3;
APPROX. LOCAnM r 1M. N,F II PETERS GATE SID
1 it
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
DREPARED FOR: TROY LOWDERMILK
C!O BROOK STILTNER
PHONE NUMBER:
244-6742
PAGE NUMBER:
1 OF 2
_EGAL DESCRIPTION:
DRAWN BY:
PETERS GATE SID; BLOCK 2, LOT 4
J.L.M.
TYPE OF WORK:
DATE:
I SITE PLAN FOR PROPOSED DRAINFIELD UPGRADE
1/12/2015
13
e7
A'
I
N
I
SCALE:
1"=40'
I
RECOMMEND THAT THE
MOA ROAD MAINTENANCE
OUT
DEBRIS
DEPARTMENT
THE ITCH 50
THATRESTRICTED.
I
I
J
U I
I Q
I
Q
Ul
(n
i
i
i
------- ----
-DITCHUNE WITH
SURFACE WATER
EXISTING
2BEDROOM
GRAINFIELD
100'SETBACK
PROPOSED
1.5 BEDROOM
RECOMMENDTHAT ORAINFIELD-
MOA ROAD
MAINTENANCE
INSTALL A DIRT
BLOCK AT
PROPERTY (SEE
NOTE).
GLACIATION (NO
VISIBLE
10128/2015)
NOTE: THE CONTRACTOR SHALL HAVE
N
L
EST LOT LINE AND THE 100 FOOT
CK TO THE DITCHLINE ALONG THE
PROPERTY LINE FLAGGED BY A
TERED LAND SURVEYOR PRIOR
Y CONSTRUCTION. /
r
coi
NOTE: WE ARE RECOMMENDING THE
f-
/1 NEW 1000 GALLON
/ SEPTIC TANK
/ DOUBLE
/
CLEANOUTS
I INSTALL FLOW
I SPLITTER–,
I,
9A
• i".': '.ate__...
:R OF BEDROOMS: 112 OF 3 (UPGRADE)
NS PER DAY (GPD): 225
ILATION RATES: 1.08 GPD/SQ.FT.
)SED APPLICATION RATE: 1.2 GPD/SQ.FT.
1M DRAINFIELD SQ.FT.: 187.5 SQ.FT.
NFIELD DESIGN:
UM DEPTH: 8 FEET (@ DEEPEST POINT)
5 FEET
H. 30 FEET
APPROVED SAND FILTER: WA
TIVE: 2 FEET
:TION FACTOR: 0.7
.L SQ.FT.: 214 --
i
0
1 • . y��r - ��� EXISTING
•' "a. WELL–
\ --CONTRACTOR SHALL
ELL–
CONTRACTOR.SHALL INSTALL
1 SWALE SO THAT THERE IS A 1001
1 TRAVEL DISTANCE FROM ANY
PORTION OF THE GRAINFIELD TO
ANY VISIBLE GLACIATION.
HOMEOWNER CONTACT THE MOA TO
PHONE NUMBER:
APPROXIMATE PATH IF
C/O BROOK STILTNER
GEG, Ltd. HAS A 8 PAGE SPECIFICATION
RESOLVE THE ISSUE OF GLACIATION ON
2 OF 2 1
L EGAL DESCRIPTION:
GLACIATION CONTINUES
DRAWN BY:
LETTER THAT PERTAINS TO THIS DESIGN. TO
THEIR PROPERTY DURING
J.L.M.
TYPE OF WORK:
DATE:
COPYESDI THE LETTER CONTACT
OG.
WINTERTREEZING CONDITIONS.
– – _
1/12/2016
–
– – – — – _
–
BY P
GEG. BY PROCEEDING FORWARD WITH THIS
MALCOM DRIVE
INSTALLATION, THE ENGINEER, WELL DRILLER,
CONTRACTOR AND PROPERTY OWNER AGREE
THAT THEY HAVE READ THESE
EXISTING CULVERT
SPECIFICATIONS AND AGREE TO ACCEPT THE
TERMS AND CONDITIONS OUTLINED.
— — — — — — — — —
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
PREPARED FOR: TROY LOWDERMILK
PHONE NUMBER:
PAGE NUMBER:
C/O BROOK STILTNER
244-6742
2 OF 2 1
L EGAL DESCRIPTION:
DRAWN BY:
PETERS GATE SID; BLOCK 2, LOT 4
J.L.M.
TYPE OF WORK:
DATE:
a DESIGN OF DRAINFIELD UPGRADE
1/12/2016
0
CD
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
3701E. TUDOR ROAD,$UTE 101'AWHORAGE. AK 8950]' PMW(MI 337E170 -F (M) 3383246'NMTE. W gem—nolnemmp.com
SOIL LOG - PERCOLATION TEST
LEGAL DESCRIPTION: PETERS GATE S/D; BLOCK 2, LOT 4
PERFORMED FOR: TROYLOWDERMILK DATE: 1/5/2016
DEPTHORGANICS
(feet) _ _ TEST HOLE #1
1 } ¢l, SM (LOAM)
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
GP TO SP
WITH SOME
SILT
BEDROCK
SOIL CLASSIFICATIONS
DATE
os
GW
_ J
ORG
° r .GP
1/12/2016
2
6.5
ML
6"
GM
CL
GC
6.5
OL
6"
5
MH
.... .
•,• •.•
SP
6.5
CH
6"
SM
< <<,'
OH
8
6.5
0"
q
SC
DEPTH TO
GROUNDWATER
DATE
DRY
1/5/2016
DRY
1/7/2016
DRY
1/12/2016
2
6.5
DATE READING
CLOCK NET TIME
TIME (MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
1/5/2016 1
6"
"
2
6.5
0"
6"
3
6"
4
6.5
0"
6"
5
6"
"
6
6.5
0"
6"
7
6"
8
6.5
0"
6"
9
6"
10
6.5
0"
6"
11
6"
12
6.5
19 PERCOLATION RATE 1.08 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ENO
SOILS LOGGED BY: JODYMAUS PERCOLATION TEST PERFORMED BY: JODYMAUS
COMMENTS: PERCOLATION READINGS ARE WITHIN 1116 OF INCH.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP RFO MED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I f la iL
\\ r MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
I ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 2644720
ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME PHONE EW
�S T �i'L575 ❑UPGRADE
MAILING ADDwL--=.-T,
167LEGAL
DESCR
LOCATION �2
NO. OF BEDROOMS L,
O Y
DISTANCE TO: Well / sorpuon ar 6y
Dwelling
PERMIT
Olo to
Z
w
Manufacturer A^/
�/r-C'�7y
M vial �—
No. of compartments Z
ci gallloons
Liq. /p a
IF HOMEMADE:
Inside length
Width
Liquid depth
d V Z
DISTANCE TO:
Wall
D el ng
PERMIT NO.
S? 4
Manufacturer TT
Material
Liquid capacity in gallons
=
DISTANCE TO: Wall
ountlatior)� Nearest to n
PEf3pa{T On
C7
_, 2
w
No. of lines Length of ch line'
Total len n f nes Trench wi h
M
Distance between lines
f
H
Top of the to finish grade 4.
inches
Material beneath the
,�/
Total effective absorption e
inches
W
Length Width
th
PERMIT NO.
Qv F
W Q.
W
Type of crib Crib diameter
r' depth
Total effective absorption area
w
DISTANCE TO: Well
wilding foundation
Nearest lot line
W
Class Dep
Dril er
Distance to lot line
PERMIT NO.
3
DISTANCE TO: Building foundation
Sewer li
Septic tank
Absorption area(s)
OTHER
s
PIPE MATERIALS
v�
SOIL TEST RATING
�7
I L-.� IL
_
INSTALLER
�� QG[lLOF_
REMARKS
S[. STt7r7 DrtiL1. itDE(1[IA7;E�7
2 Bor.ya:
y F Al�
s��P •ti$-
ri« •� 9 t
r�i
Me«+ A. Mels
V.. . Nei
�F •
APPROVED S` „E. I E= 1 i DATE LEGAL
SRD I=
Y.ruLE RIVERLAS'4% i:-)N
/ 11ll;�g1 a T
n /7
MtJN I C I PAL I rrN' OF ANCHC]i-:zACGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET, ANCHORAGE, AK, 99501
264-4720
C3N— S I T E E3EWE R ,BSc W ELL PERM I T
PERMIT NO: 840696
DATE ISSUED: 08/15/84
APPLICANT: MYERS CONSTRUCTIOIN
ADDRESS: % S&S ENGINEERING
EAGLE RIVERE, AK. 99577
CONTACT PHONE: 694-2979
LEGAL DESCRIP: SUBDIVISION: PETERGATE
LOT r�
BLOCK: 2
SECTION: 11 TOWNSHIP:
15N FLANGE: 114
LOT SIZE: 1.42A (SO.FT. OR ACRES)
MAX BEDROOMS: 03
Listed below'are the options available to
you in designing
your septic
system. Choose the.option that best fits
- - - - - - - - - - - - - - - - - - - - -
your site.
-
TRENCH
- - - - - - - -
L EE: ID
- - - - - - - - - -
W _ DRink I N
DEPTH TO PIPE BOTTOM (FT.). 4.0.
4.0
4.0
GRAVEL DEPTH (FT.) 6.0
0.5
3.5
TOTAL DEPTH (FT.) 10.0
4.5
7.5
GRAVEL WIDTH (FT.) 2.5
17.0
.5.0
GRAVEL LENGTH (FT.) 32.0
34.0
41.0
GRAVEL VOLUME (CU.YDS.) 19.2
21.4
30.3
TANK SIZE (GALS) 1,000.0 **
1,000.0 **
1,000.0 **
SOIL RATING (S(I.FT./BR) 125
125
1125
** TANK MUST HAVE AT LEAST TWO COMPARTMENTS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
I certify that:
1. I am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality,of Anchorage (MOA) and the State of Alaska.
2. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria of this permit.
3. I will adhere to all MOA and State of Alaska requirements for the set back
distances from any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that this permit ;s valid for a maximum of 3 bedrooms and
any enlargement will require an additional permit.
IF AI[IFT•STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS
WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE
ELECTRICAL WORK. MUST BE DONE BY A LICENSED ELECTRICIAN.
SIGNED
APPLICANT
ISSUED B
Y
DATE:
: MYERS RUCTI N
DATE-
- --- - ---=------- '
SOILS LOG
MUNICIPALITY OF ANCHORAGE
1 • �+l DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION
825 L. Street, Anchorage, Alaska 99501 264-4720 TEST
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: pc-�LS DATE PERFORMED: e3 13
LEGAL DESCRIPTION: LOT B �- Ae. Z S E S/o
r7ys SLOPE SITE PLAN
E1{1 0P_67t wl \ L
1
i( ;•
2 ��% RefstQ1SN Sta.�n�'j sk"r — 0
�1
Date
Gross
Time
Net
Time
4-
Net
Drop
5
5-
6-
6
7-
7
c6b
8-
9
9-
10-
1011
11-
12-
12
13
13-,
' rC.1
s
14
15 µvt
16
t
17 ; *qPt.• .qa
18 a
19-
all
20 S• fio. 14371 r
WAS GROUND WATER
ENCOUNTERED? NJ O
IF YES, AT WHAT
DEPTH?
'11
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
i
F• .-bfev
t��f0~•••••••ie•••• Ea PERCOLATION RATE
40FESStaK (minutes/inch)
hp•►
TEST RUN BETWEEN FT A)IIB•t FT
PERFORMED s'8 � i "GINMRIHi
��%+'' CERTI F I E DATE�p
RIVER. ALASKA 29577
PH. 634-2970
72-008 (6/79) --
. f WATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geologicat a GeoP1hysical Surveys
Drilling Permit No.
LOCATION OF WELL (Ploa.e complete gime$ is, 1a or it.) A.D.L. No.
to Borough Subd:rioloa Lot Block lb. 'A4t r e. E.atI.R No. Townohl 111 11, Range E� Meridian
—ef�ef_ef� S� Is
ic.11 DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS
S. OWNER OF WELL:
Mr. Paul Myers
Address: P.O. Box 351
Street Address and Ano Of well Location
Chugiak, Ake
2. WELL LOG FeetBelo.
So, face
Malarial
0. WELL DEPTH: D. OA9TE OFCOMPLETION
.O N84
Typo Top Bottom
ft(flnol)
os, I d ers san ,grave , IS
"—
G. ❑Coble feet oterr ❑ Driven
greens one
❑Dug
Grey rock
❑ Awg"r QJotNd [:3 Barad ❑ other
T. USE: Do..otle (3 publicSupply❑ Induolr y
Brown rock water 60 64
❑ Irrigation ❑ Recharge ❑ Cemmerlcol
I Greenstone qu
❑ Test WNI ❑ other;
B. CASING. ❑ Tbreed.d n(w.lded
dia., 6 '-. 1 -2 -9 --ft. Depth III �_ lee./lt.
ado.. In. tom ft. Depth Stickup ft.
I. FINISH OF WELL:
Type' OlcI
SICtlM.ek Slce: Length:
F P 13`
set be+.e.o 11. and 11.
\�Q OF 0.0ZE
Boe Yfllting Brerel pock
t
10. STATIC WATER LEVEL: ft.
❑ ADore at ❑ Belo. Iona Dot rorfau
r
Equipment woad:,
a
16. WATER WELL CONTRACTORS CERTIFICATION:
II. PUMPING LEVEL below Iand surface and TIELD
It. offer —bre. ►a.aing g.P...
it. ellerhre. pumping—O.P.n,
12.GROUTING wall Oroul.d: Q Too ❑ No
Material: ❑ Neat Cement ❑ Other:
IS. pulePt (it available) HP C
a
Length of DLP Pip, It. tapodily 9p•., a
r
Subs,. ❑ ds, ❑ Contriflcol ❑ other
Id.REMA S: _
"Production of 1/2 GPM
IS. Water Tomporann --
Thin .all was orilbd under my Jurisdiction and this report la it., to the bast of my hn..l.dg. wed belief;
i -Magnuson_Dri22jmg AA 5385
Registered Busmen No., 00"577 License Numbs,
Addra"ePnO• Box 770504 Eagle River, Ak.
Signed:
I
• pars, 02• W WR (11/01)
R"
Distribution: WHITE•St.r.
oat,: Sept,
F Uc
Municipality of Anchorage
On -Site Water & Wastewater Program
(907)343-7904 K a
r f v fi
i CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 051-541-12 Expiration Date: f
1. GENERAL INFORMATION
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
PETERS GATE S/D; BLOCK 2 LOT 4
24947 MALCOLM DRIVE *CHUGIAK, AK 99567
TROY LOWDERMILK Day phone
24947 MALCOLM DRIVE *CHUGIAK, AK 99567
BROOK STILTNER Day phone 748-0156
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual On-site
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for: NSA - Distance:
Received by:v y Date:
COSA to be released the engineer, unless olheMW requested by the engineer.
COSA Fee $ �—zb , 3 t (Y
, • o
Date of Payment �� (2' 1 J
Receipt Number CJ 2 G
COSA # © SC- i S i 2-2?
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK, 99507
Engineer's Printed Name
Engineer's Comments:
JEFFREY A. GARNESS, P.E.
In conducting (his evaluation, GEG provided an engineering evaluation of the wall and/or septic system in accordance wifh the
guidelines and regulations established by the Municipality ofAnchorage and industry practices. The reported results describe the
condition of the systems on The date/s of the evaluation. Separation distances were measured to readily identifiable features.
Hidden defects or encroachments may exist That were not identified during the evalualion.The operational life of all wells and septic
systems depend on a variety of variables including, but not limited to, soil conditions, groundwater levels (that may fluctuate during
the year), quality of construction (materials and workmanship), and the water usage of the family ulifiang the systeMs. These
conditions can vary, and are outside the control of GEG. Satisfactory fast results do not guarantee future performance of the
systeMs; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system.
GEG makes no representation whether an alternative wall or septic system can be installed an the property in the event either of the
current systems fail. The content of this report is for the sole benefit of the persor✓p my who retained GEG. Reliance upon the
information provided in this repon by any olherperson or party, including but not limited to subsequent property purchasers, is not
authorized. In short, GEG disavows any legal duly to anyone other than the persoNparly who paid for this report.
6. DSD SIGNATURE
System #1 Approved for 3 bedrooms.
System #2 Approved for
Disapproved.
Conditional approval for
bedrooms.
Phone
337-5179
Date
®bf9FESS� �e
s
bedrooms, with the following stipulations:
ON-SITE r�
m.
?-s WASTEWATER
mac,
Original Certificate Date: ( 2 1. "-1!o
The Municipality or Anchorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTCHMENTS:
COSA Checklist_ Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
(Rev. 10112/12)
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: PETERS GATE; BLOCK 2, LOT 4 Parcel ID: 051-541-12
A. WELL DATA ISTORAGE TANK WAS BY—PASSED FOR WELL TEST
Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (YIN) YES
Date completed 9/$/1984 Sanitary seal (YIN) YES Wires properly protected (YIN) YES
Total depth 90 ft. Cased to 29 ft. Casing height (above ground) 12+ in.
FROM WELL LOG AT INSPECTION
Date of test 9/8/1984 10/28/2015
Static water level UNK ft,
Well production, 0.5 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml. Nitrate '1.63 mg./L.
Arsenic: ND ug./L. Date of sample: 10/27/15
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL
Tank size 1000 gal. Number of Compartments ?
9—
p.m-
Collected by: GEG. Ltd.
Date installed 12/11/2015
Cleanouts (YIN) YES
Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (YIN) N/A
Date of pumping NEW Pumper —
C. ABSORPTION FIELD DATA *BELOW nNAL GRADE NORTH SOUTH
g/1984 DEEP TRENCH
Date installed 1/22/2016 Soil rating .p.d./ rftl/bdrm) 1_2 System type SHALLOW—TRENCH
Length 21/30 ft. Width 2.5/5 ft. Gravel below pipe 6/2 ft.
Total depth 10.3 *6.2 ft., Eff. absorption area252 214ft2 Monitoring tube YES Depression over field NO
Date of adequacy test 10/28/2015 Results (Pass/Fail) PASS For **3 bedrooms
Fluid depth in absorption field before test 42.5 in. Water added 343 gal. New depthy5_25 in.
Elapsed Time: 190 min. Final fluid depth 58.5 in. Absorption rate ?_.: ' **300+ g,p,d,
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date —
**TESTED 1984 TRENCH ON 10/28/2015 FOR 2 BEDROOMS. ADDED ADDITIONAL TRENCH 2/2016
TO MAKE 3 BEDROOM SYSTEM
t
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N
"Pump on" level at in. "Pump off' level High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lot:
Absorption field on lot 100'+ On adjacent lots
Public sewer main 75'+ -
Sewer/septic service line, 25'+
Public sewer manhole/cleanout 100'+
Holding tank
Animal containment areas 50'+ Manurelanimal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+
Water service line 10'+ Surface water *103' Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
*SEE 2016 PERMITTED DESIGN COMMENTS REGARDING GLACIATION.
G. ENGINEER'S CERTIFICATION
i certify that i have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Pri ted Name JEFFREY A. GARNESS
Date 1 74/1&
(Rev. 11/05)
csflda of
m
49N "r-oJ
S�
A*VU,LI SEWARD & ASSOCIATES LAND SURVEYING 694-0829
1 HEREBY CERTIFY THAT i HAVE SURVEYED THE SCALE' -"!
FOLLOWING DESCRIBED PROPERTY- / J 3d t OF At 04
AND THAT NO E466ACHMErNTS EXIST EXCEPT AS �3o%f .v /v•' 54
INDICATED. IT IS THE RESPONSIBILITY OF THE i $
OWNER TO DETERMINE THE OCISTENCE OF ANY GRID= .........••••• 6
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI- 4y o....
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FS:4 t , s
ANY DATA HEREON BE USED FOR CONSTRUCTION /`387 ;t
OF FENCE LINES, OR FOR ESTABLISHING BOUND- ..+"
ARY LINES. DRAWNS z ydg+�
n,
\D
o
csflda of
m
49N "r-oJ
S�
A*VU,LI SEWARD & ASSOCIATES LAND SURVEYING 694-0829
1 HEREBY CERTIFY THAT i HAVE SURVEYED THE SCALE' -"!
FOLLOWING DESCRIBED PROPERTY- / J 3d t OF At 04
AND THAT NO E466ACHMErNTS EXIST EXCEPT AS �3o%f .v /v•' 54
INDICATED. IT IS THE RESPONSIBILITY OF THE i $
OWNER TO DETERMINE THE OCISTENCE OF ANY GRID= .........••••• 6
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI- 4y o....
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FS:4 t , s
ANY DATA HEREON BE USED FOR CONSTRUCTION /`387 ;t
OF FENCE LINES, OR FOR ESTABLISHING BOUND- ..+"
ARY LINES. DRAWNS z ydg+�
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
4107
a
y f
3u[f:
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. ()5/ -145 — /a COSA # bu l � l
Expiration Date: q — /P-- O 7
1. GENERAL INFORMATION
Complete legal description
P E L45k
S GAM
81- A CFC 2 j Z -07 -
oTLocation(siteaddress)
Location (site address)
/19ALCoLr✓l
Rr✓E CNft"i.4K
Current Propertyowner(s) Dayphone 24./9y
Mailing address
Lending agency
Mailing address
2G�9t.�7 �jLGdGrrt !�/Ti✓l Cffd�Y.¢k
Day phone
Real Estate Agent �i/� ! /G row/ Day phone %%l OZy4/
Mailing Address 6:4rce
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Z
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Weil ❑
Public Water System ❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding Tank ❑
Community On-site ❑
Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation,
based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure Indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm
Address
Engineer's Printed Name
Phone 702-e
Date e14
�...
.............
5. DSD SIGNATURE�' . 51e.aR W. Egg 2
to �.,�•,• PE 6:36 : v�
Approved for bedrooms. �d�Fo�nrcssr�;.����<�-�
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: ,,/ 14 '29�e-c_;?� Original Certificate Date: (4 — /a — 0-7
(Rev. 11105)
Municipality of Anchorage
• �' Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: ?Er15'e S 047-e 14 8L 0 e k a. ZarV Parcel ID: 05/--17-4 1-12
A. WELL DATA
Well type _r_ If A, B, or C provide PWSID # _ Well Log (Y/N) —Y
Date completed I2106y Sanitary seal (Y/N) 4— Wires properly protected (Y/N)
Total depth 10 ft. Cased to 2 7 ft. Casing height (above ground)in.
FROM WELL LOG AT INSPECTION TT
Date of test
Static water level ft.
Well production Q.5 g.p.m.
WATER SAMPLE RESULTS:
Coliform —.6—colonies/100 mL Nitrate /. , mg/L
Arsenic: 6,37? ug/L dale of sample:�S 7
B. SEPTIC/HOLDING TANK DATA
7
ft.
+ g.p.m.
Other bacteria _Q colonies/100 mL
Collected by lc .ri Lzr .
Tank Type/Material-GZE'E& /STEEL Date installed 9�y
Tank size — gal. Number of Compartments Z Cleanouts (Y/N)
Foundation cleanout (Y/N)4 V Depression over tank (Y//NN) High water alarm (Y/N) Al
Date of pumping I:y /Q 7 Pumper �. %e IT
C. ABSORPTION FIELD DATA
Date installed Soil rating (94444te or ft2/bdrm) /1 S System type TTIE.r/G' f/
Length .21 ft. Width Z. 5 ft. Gravel below pipe 4- ft.
Total depth Zo ft. Eff. absorption area2-572ft2 Monitoring tube 4__ Depression over field .L
s Results (Pass/Fail) Jr For 2 bedrooms
Date of adequacy test -&1
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time:/20 min. Final fluid depth in. Absorption rate >= 300 g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type)yxtk If yes, give date
D. LIFT STATION /J/I
Date installed
"Pump on' level at in.
Datum
E. SEPARATION DISTANCES
Size in gallons-
Manhole/Access (YIN)
'Pump off' levet at in. High water alarm level at in.
Cycles tested Meets alarm & circuit requ' ments?
SEPARATION DISTANCES FROM WELL ON LOT TO:
i
Septic tank/lift station on lot /0Q 4'
Absorption field on lot /do 'f
Public sewer main
r
Sewer /septic service line /Gtr?
Animal containment areas 0 rt
r
On adjacent lots /0Q t
On adjacent lots /Q0 it
Public sewer manhole/cleanout
Holding tank
(�
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
r,F
Building foundation S4' Property line !SO Absorption field /Q
Water main Water service line 2514 Surface water /00 f
Weiss on adjacent lots/00 �'f'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line SQ '� Building foundation/Q Water main / it
Water Service line 75 r Surface water /00 r Driveway, parking/vehicle storage z0
i
Curtain drain Wells on adjacent lots ZQQ fi
F. COMMENTS
(E.•ur•"�k%I
G. ENGINEER'S CERTIFICATION ;yAP •.•�f9?'
I certify that I have determined through field inspections and jo :491U '•. �
review of Municipal records that the above systems are in 110 •"' """"•
conformance with MOA COSA guidelines in effect on this date. •; 't .......
Slwjjn W.Eng
W
Engineers Printed /Q r7Name C Tgo- Ey( En/G ��� s, PE 6256
••F
Date 6/6 ^F •..........
COSA Fee $
Date of Payment II'tt,,D
Receipt Number
(Rev. 11105)
Waiver Fee $
Date of Payment
Receipt Number
II IV UTILITY EASEMENTS I I
LOT 3 -
POWER POLE
WOODEN
1
J
U
2
SEPTIC cLEAN0UT5—L\,',"'
8.1' X 16.2' SHED
,3ao
Q
LLJU�
o
41
�
fes'
'
W
in
LOT 4
1.24 Acres
Y
30.00'
l
;K.
I*'�z
STORY
FRAME
S� 6 WqL.
B P Cly,4y_.
N 89'57 4NZ 110.08—.
MALCOLM DRIVE
LOT 6
i ---
Q. 3
i LOT 5
PLOT PLAN _ AS BUILT X SCALE 1' - 40' GRID NW 1262 Project No. --_97-066
Lang & Associates, Inc. 11500 Dory! Avenue, Anchorage, Alaska 99515-3049
(907) 522-6476 Phone
Registered Land Surveyors (907) 522-4625 Fax
kglanglsOalaska.net / jclanglsOaloska.net � OF ,.•••••A. ,9sp`l�J�
1 hereby certify that 1 have surveyed the following described property.
P'
LOT 4, BLOCK 2, PETERS GATE SUBDIVISION (PLAT No. 74-146) o;�: 49� *`jQ/
Mahoroge Recording District, Alaska, and that the Improvements situated thereon an :...
...........
within the properly lines and do not encroach onto the properly adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed -b' ...• .•• _.. ..•.
promises and that then are no roadways, transmission lines or other, vielbl* KENNETH .UNG
easements on said property except as Indicated hereon.
Dated this the 3R= D of �? ZOp Q LS -5202
�— aY MLA _Z—. at Anchorage. Alaska �4 �Rp•151 L7f�j,•
It Is the rosponsibtilty of the owner to determine the exlsfence of any easements, ""0N
covenants, or restrictions which do not appear on the recorded subdivision plat.
Analytica International, Inc.
4307 Arctic Blvd.
Anchorage, AK 99503
Phone: 907-258-2155
Fax: 907-258-6634
Northrim Eng
Report Date:
5/22/2007
Attn: Steve Eng
Receipt Date.
5/8/2007
17237 Bear Paw Circle
Sample Date:
5/8/2007
Eagle River, AK 99577
Sample Time:
9:00:OOAM
907-694-7028
Collected By:
SA
Fax: 907-694-7026
Client Sample ID:
Peters Gate B2 14
Sampling Location:
Parameter Result Units Flags
s ISiRL
Client Project:
Northrim Eng
Sample Matrix:
Aqueous
COC #:
59379
PWS#:
Total Coliform <MRL CFU/IOOmL 1.0
Residual Chlorine:
5/8/2007 SG
Comments:
Lab#: A0705098 -01A
Flae Definitions:
MRL = Method Reporting Limit
MCL = Maximum Contaminant Limit
B = Present also in Method Blank
11= Exceeds Regulatory Limit
M = Matrix Interference
J = Estimated Value
D = Lost to Dilution
•• = RL higher than MCL; target not detected
TNC = Too Numerous to Count - result rejected
CF = Confluent Growth - result rejected
TCNG = Turbid Culture No Growth - rejected
Analysis Methal Prep
s MRL MCL Method Prep Analysis
Parameter Result Units Flags Date Date Analyst
4500-NO3E (Aqueous) - Nitrate Test was conducted by: Analytica - Anchorage
Nitrate asN 1.87 mg/L 0.50 /0 5/8/2007 5/8/2007 AJ
Lab#: A0705098-OIB
Analysis Method Prep
s MRL MCL Method Prep Analysis
Parameter Result Units Flags Date Date Analyst
200.8200.8 (Aqueous) - Family Well Water I Test was conducted by: Analytica - Thornton
Arsenic 0.379 ug/L 0.15 /0 200.8 5/1812007 5/18/2007 KB
Lab#: A0705098 -OIC
Analysis Method
Pre Prep
Analysis
Parameter Result Units Flags
s ISiRL
51CL Method Date
Date Analyst
92228 (Aqueous) - Membrane Filtration MF
Test was conducted by: Analytica - Anchorage
Bacteria, Other <MRL CFU/IOOmL 1.0
5/8/2007
5/812007 SG
Total Coliform <MRL CFU/IOOmL 1.0
/ 5/812007
5/8/2007 SG
Reported by: Claire Toon,
Laboratory Project Manager
Page 1 of 2
�s
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program . A I
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.enchorage.ak.us
(907)343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D._O151— Jbil— /'L HAA#
Expiration Date:
1. GENERAL INFORMATION
t
Complete legal description 1 o I H T3 (L 2
Location (site address or directions) yr9Y7 HAL pa
-
Current Property owner(s) co rg 4 t i si�., N �w ..rT ^ay phone
Mailing address,
;'-.:.-.
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Day phone
t olte13o.t t/,tr, „0 P L101 Day phone
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
7
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work.
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
211
❑
Individual Holding tank
❑
❑
Community On-site
❑
❑
Public Sewer
❑
7
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm f y4k.C&, T- 1
Address 7�0 3 t t'i 1 ✓ �-�t Zvi
Engineer's Printed Name 1 o wy-c S' ... V Ia Kd
5. DSD SIGNATURE
__IZ Approved for _ 1 bedrooms.
Disapproved.
Phone Q4 — 3j a
Conditional approval for bedrooms, with the following stipulations:
Additional Comments Note: The well for this property meets existing State and Municipal
Codes. There are nitrates present. It is suggested that periodic testing be per-
formed to insure the wells continued suitability. Current nitrate concentration is
7.55 me/1 EPA maximum concentration is 10.0 mg/1. More information on nitrates
is available from the On -Site Services Program, at 343-7904.
Attachments:
HAA Checklist X Maintenance Agreements
Septic System Advisory Supplemental Engineer's Report
Well Flow Advisory X_ Other
By: I y ��., / /!� Original Certificate Date: �4 -03
(Rev. 0103)
Municipality of Anchorage
' Development Services Department
Building Safety Division
On -Sita Water & Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 995196650
www.ci.anchorage.ak.us
(907)343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: L -a+ N aK 9- '�' (Zk 12 5 C Xr k Parcel ID: 061- ,5Y 1- 11-
A. WELL DATA
Well type -4L
If A, B, or C provide PWSID #N/A
Date completed iwlpy Sanitary seal (Y/N)
Total depth -Ia_ft.
Cased to A-CLft.
FROM WELL LOG
Date of test
Static water Level
0" it a ft&*A ft.
Well production
to. -S g.p.m.
WATER SAMPLE RESULTS:
Well Log (Y/N) Y
Wires properly protected (Y/N)
Casing height (above ground) IZ in.
AT INSPECTION
u / AP
-6(0 ft.
0-63 g.p.m.
Coliform _��colonies/100 ml. Nitratemg./l. Other bacteria N t� colonies/100 ml.
Arsenic: V/ mg./l. Date of sample: b ( 03 Collected by:
B. SEPTICIHOLDING TANK DATA /
Tank Type/Material L—e-. Stt1AAJ Date installed 4 { g Y
Tank size I&0Q gal. Number of Compartments %L Cleanouts (Y/N) x
Foundation cleanout (YIN) t Depression over tank (YIN) -L!- High water alarm (Y/N)
Date of pumping y 16 -0 3 Pumper . IZ
C. ABSORPTION FIELD DATA
Date installed Q : Soil rating (g.p er ft'lbdrm) - System type YAtt&& �
Length ft Width .2_ �� fl. Gravel below pipe 4P ft.
Total depth 1,(2_ ft. Eft. absorption area 2,6_Z-ftr Monitoring tube -�L- Depression over field N
Date of adequacy test y iy-v 3 Results (Pass/Fail) _" For a bedrooms
Fluid depth in absorption field before test pin. Water added 3ev gal. New depth LZ in.
Elapsed Time: 1A0 min. Final fluid depth _JL in. Absorption rate >= 300 g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) N 0 If yes, give date f/
D. UFT STATION
Date installed
'Pump on" level at_ in.
Datum
E. SEPARATION DISTANCES
gallons
off" level at _ in.
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot /;up t
Absorption field on lot
Public sewer main "A
Sewer /septic service line I" t
(Y/N)
water alarm level at
Meets alarm & circuit requirements?
On adjacent lots i,> 1 ao
On adjacent lots 'loo f
Public sewer manhole/cieanout N%A
Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation Property line 6 t Absorption field 15
Water main N �A Water service line a 5 t Surface water I O -C) +
Wells on adjacent lots 100 -�
in.
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10.0 Building foundation 3 O Water main %A
Water Service line A ±5- 4 Surface water 12!0— Driveway, parking/vehide storage 7-y 0
Curtain drain N l b Wells on adjacent lots �}/2/.o
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certffy that I have determined through field Inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name I a l,%e N �� r I�Lw ►a
. 1
Date
-00
HAA Fee $ 06
Date of Payment 10/134 3
Receipt Number ITIS -1 L,
(Rev. 12/07)
Waiver Fee $
Date of Payment
Receipt Number
nge,Ess'. --
r
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
Water Well Advisory
Health Authority Approval # 030276
During a recent Health Authority Approval on-site inspection and test of the
potable water supply well on Block 2, Lot 4 of Peters Gate subdivision, the
well's productivity was determined to be 0.33 gallons per minute. The
minimum well productivity required by this Department (AMC 15.55) for a
2 -bedroom residence is 0.2 gallons per minute. Although the subject well
currently exceeds this minimum requirement, all parties concerned are
advised that the production capacity of the well may fluctuate. Restriction
of non-critical water uses such as washing cars and watering lawns and
gardens may be required.
This advisory must be attached to all copies of the subject Health Authority
Approval.
f 86-23-03 MOM FROIhCTLF EM71RMLINTAL SRV BOTSCIS301 T -14E P.C2/C5 F-443
SGS
SGS Re.t.#
1033588001
Client Tame
Tobben Spurklard P.E.
Project NameAt
Various
Client Sample ID
Lot 4, Blk 2 Peters Gate
Mstris
Drinking Water
Sumple Renvrks.
All Date6MMes are Alaska Standard Tlme
Printed Date/rime 06/2312003 15:22
Collected DatwTlme 06/18.2003 11:00
Recelved DateMme 0611 003 15:32
Tecbnical nla*cto � Ste a C. Ede
Par4nwer Resin PQL Units Method Conuiner ID Allowebie Rep Arwlpia
Le9i•s Dete Dale Ind
Haters Department
Kitnte•N 7.55 0.100 mg1L EPA 300.0 B ("10) 06118'03 JS
VACroblology Laboratory
Taal Coliform 0
calilMmL 3%11892220 A (<-I) 061I1L'03 KAP
:;•
a
. Z
L
-
.I
YO /i T'i `Vnr i ct .
Cr,J
AS -BUILT
1 hereby certify that 1 have surveyed the follu,ving desmhec
pr[mpeny:�L 7 /GG1 7
LJ. •i' -a Fr fir/-
��� 5
Anchorage Recording Preankt. Alaska, and that the impruve•
menti situated thereon are within the proper,%. lines and du not
overlap or encroach on the property lying adlacrnt thereto, that
no improvements on property lyintl adjacent thereto encroach
On the pno roadwavi.
transmoiiiuntses li es or wher visible in qut-stitin and tcasementsat thereare on said propeits
trtcept as indicated hereon.
Oared at EaSle Rls•er. Alaska , •.'-
T
chs- 1C day of i9 �4 . f,1
t' KALE ROBERT C, JOHNSON p `
Re ERT
Sunc or N•
,':. " •'•'� &,t :,•C•i5,i, Eay!e River. Alaska 995,
•`4..,... .Mn ,... .•..
MUNICIPALITY OF ANCHORAGE
DIVISION OF Eh'VIROK4ENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Informatio Application Date Z/1/p 1x Cf
(a) Legal Des i t on (include lot, block, subdivision, section, township, range)
L' `c
Location (address or directions)
/ N 4tl
S1iZP7
(b) Applicants Name! R'141Q_rf Cd Is'T / Telephone - Home Business
Applicants Address SS 004q /7i6e >z.P
(c) Applicant is (check one) Lending Institution ; Owner/builder
Buyer [::::[ ; Other = (explain);
(d) Lending Institution -'l% 0-'�..i Telephone
Address
(e) Real Estate Co. b Agent iU v oa
Address
Telephone
1- ZID
(f) the HAA to the following address:
£ G.`101 N[ c"iiU\C�
rcr !i::UF��x
2. Type of Residence
Single -Family Multi -Family
Number of Bedrooms 2
3. Water Supply
Individual Well D�T Community
Other (describe)
Public =
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal
Onsite r5;�'T Public M Community M Holding Tank Q
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
Engineering Firm Providing Inspections Tests File Search Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure Indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
Name of Firm Telephone
SRO 106)c IN(s
Address VFa AIAo". �".!'%Vku.
Date—
. i
i�r: • ' .
•/. moi,• � •t� ,•�
(ENGINEER SEAL)
No. 1437-E •.'•.•
6. DHEP Approval
f��ic'•,,• •'�-,R
Approved
for
bedrooms By
Date
Approved
Disapproved Conditional
Terms of
Conditional
Approval
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE PWQUIRE-
MENTS. EMPLOYEES OF DUEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DHEP SEAL)
RR4/ej/D18
[Page 2 of 21 7-19-84
A. WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEAM AUTHORITY APPROVAL (HIAA)
CHECKLIST - FEBRUARY 1984
Legal
MUNICIPAL17Y OF ANCHO?.ACZ
DEPT. OF HEALTH &
E.WrON:AF-14 AL PR- Ci:TICi!
Nov 2
��CEIVED
Well Classificati U!d K If A, B, or C, D.E.C. Approved(Y/N)
Well Log Present f) Date Completed _ (7/8 174 Yiel Cd�
Total Depth 0 Cased to Z9 '&(e Depth of Grouting
Static Water Level Zr% Pump Set At CAL (.(
Casing Height Above Ground Sanitary Seal on Casing ( )
Electrical Wiring in Cmduit((Y D Depression Around Wellhead (� )
Separation Distances from Wall:
To Septic/Holding Tank o1 Lot /� f On Adjoining Lots /OD
To Nearest Edge of Absorption Field on Lot / 4- On Adjoining Lots 1677 <
To Nearest Public Sewer Line '4J M To Nearest Public Sewer
Cleanout/Manhole N 114 To Nearest Sewer Service Line on Lot
Water Sample Collected By 5 , 5 t, xic i Date
Water Sample Test Results C
Comments '
B. SEPTIC/HOLDING TANK DATA
Date Installed B Size /0490 No. of Caq=tments z
Standpips (Y L) Air -tight Caps am) Foundation Cleanout (Y )
Depression over Tank Date Las Pumped x J e W
Pumping/Maintenance Contract cn File Y ; for
Holding Tank High -Water Alarm (Y Temporary Holding Tank Permit Y
Separation Distances from Septics Tank:
To Water -Supply Wall /DU '�c To Building Foundation.
To Property Line d To Disposal Field
To Water Maiwtervice Line 30 To Stream, Pond, Lake, or Major Drainage
Course '0UL7 a.Je=
Comments /(ID n/e
Receipt $
Date Paid: 11-at-Fc+l
Amount:-WCS;:_
[Page 1 of 21
2-15-84
C. ABSORPTION FIELD MTA ^
Soils Rating in Abs tion Strata IZSAType of System Design (
Date Installed B 44' Length of Field Z
Width of Field 30 a Depth of Field /D
Gravel Bed Thickness Z ��
Square Feet of Absorption ea Z S 2 Standpipes Present Y �)
Depression over Field ( ) Date of Last Adequacy Test /V a �✓
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water -Supply Wall /M �-� To Property Line
To Building Foundation 30 To Existing or Abandoned System on
Lot iCJ O AJ E f On Adjoining Lots 30 To Water afaisr/Service Line � �f To Cutbank(if present) -oU o k J f
To Stream/Pond/Lake% Major Drainage Carse AJO n/ Agr
To Driveway, Parking Area, or Vehicle Storage Area jz /f
Ccrents 4uv Aajer
D. LIFT STATION
Date Installed Dimensions
Size in Gallons /Access (Y/N)
"Pump Qtr Level at Off" Level at
High Water Alarm Level at I — nt (Y/N)
Tested for Pumping Cycies during Adequacy Test. Meets MDA
Electrical Codes(Y/N)
Cc auents
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MDA HAA Guidelines in effect
on the date of tris inspection.
Signed S a18 "Itfewr bats
Calpany ;dLE P105k�� MDA No.
M/d5/s
[Page 2 of 21