ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP131464
PID Number: 018-271-18
Dwelling: 0 Single Family (SF)
❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New 0 Upgrade
Name:
SCOTT POWELL
ABSORPTION FIELD
❑ Deep Trench ❑ Shallow Trench K Bed ❑ Mound
Address
15320 CURVELL DR., ANCHORAGE, AK
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
0.7 GPD/SF
3.2 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
.5 Ft.
Gravel depth beneath pipe
0.5 Ft.
Subdivision
Block Lot
TI MBERLUX # 1
D 4
Fill added above original grade
2-2.5 Ft.
Gravel length
58 Ft.
Township Range Section
Gravel width
15 F]
Beds: Number of Lines
3
Distance between lines
5 Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank.
Line
870 Ft=
NA
I NA Ft.
Well
>100'
>100'
NA
>25'
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Capacity
Gal.
Surface Water
>100'
>100'
NA
Material
Number of compartments
Lot Line
>10'
>5'
NA
NA
Foundation
>10'
>5'
NA
LIFT STATION
Manufacturer
ANCHORAGE TANK
Capacity
500 Gal.
Curtain Drain
>50'
>50'
NA
Remarks EXISTING DRAIN FIELD ABANDONED
Pump on level at
25 in.
Pump off level atHigh
44 in.
water alarm at
22.5 in.
PER UPC REQUIREMENTS.
BAFFLES REPLACED
EXISTING CONCRETE TANK.
Pump make and model
ORENCO
Electrical Inspections performed by
MOA
PIPE MATERIAL House to tank 3034 Tank to SCH40
drainfield
Installer
A+ HOME SERVICES
Draintield SCH40 CO/MTF810
Inspector LARS SPURKLAND
BENCH MARK (Assumed elevation) 100 it
Inspeection to 2/5/14
2/7/14
Loscription
cation and de
ction
3'd 2/10/14
2�d
a
BOTTOM SIDING SW HOUSE CORNER
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
En q&%S"
At
Conditional Approval:
/fs d e_r Date
OF X i:1
�• y
i3bC-
vie '0
101,::
UKLADF..°�
H�i
Approved
Date
Vo A
nspecion epo
TH
SWING TIES
A
8
ST. C.O. C
165'
66.0'
S T. C.O. D
10.5'
64.5'
DBL. C.O. E
15.0'
61.0'
L.S. M.H. F
44.0'
38.0'
DF. MT. G
116.5'
35.0'
DF. MT. H
142.5'
67.0'
Eur.=101.8'
H2O IIEY.=9d4'
gam aEV.=9a9'
CURV
RABBIT CREEK ROAD
25 0 25 50 n 100 125 150
SCALE.• I' = 100 FT.
Monitor
2' Insulation
—Slit Barrier
NTI SCALE
NOT£.• THIS IS NOT A SURVEYED PUT. WELL A• SEPTIC
LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER
DEPARTMENT DOCUMENTATKIN. ALL LOCATIONS SHOWN ARE
APPROXIMATE.
r0 ELEKAXW
N TS
Eur.=.ax'
Filter Sand
5006 STEP TANK
0
SPURKLAND
U.
BENCH MARK BOTTOM SIDING SW HOUSE CORNER -W441j;: S V` *
ASSUMED ELEVATION 100'
SPURKLAND ENGINEERINGRECORD DRAWINGS
203 W 15TH. AVENUE TIMBERLUX #1 BM D LOT 5
ANCH. AK. 99501 JIM BOWS DATE: MARCH 5, 2014
(907) 279-3916 6240 E. 111 AVE., ANCHORAGE, AK 99516 SHEET: 1/1 GRID.3136
PERMIT #17SP131464 P1B # 018-271-18 TIMBERLUX#IBBL44SB, BWG
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131464
Tax Code Number: 01827118000
Work Type: Septic
Permit Effective Dates: December 18, 2013 to December 18, 2014
Design Engineer: SPURKLAND ENGINEERING
Subdivision: TIMBERLUX #1
Site Legal Address: TIMBERLUX #1 BLK D LT 4 G:3136
Owner/Address: POWELL SCOTT E & CATHALEEN M
13001 FLORAL LANE ANCHORAGE AK 995163140
Site Mailing Address: 15320 CURVELL DR, Anchorage
This permit is for the construction of:
N Disposal Field Y Septic Tank N Holding Tank
Lot Size in Sq Ft: 54973
Total Bedrooms: 4
N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907 -343 -
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 018-271-18
Property owner(s) SCOTT POWELL
Mailing address 15320 CURVELL DR., ANCHORAGE, AK 99516
Site address SAME
Day phone 575-7911
Legal description (Sub'd., Block & Lot) TIMBERLUX #1 BLOCK D LOT 4
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
IS all that apply)
Absorption Field ® Initial ❑ Single Family (SF) El
Septic Tank El Upgrade El
(w/wo ADU)
HoldingTank ❑ Renewal nn Duplex (D) ❑
° g - Multiple Dwellings ❑
Privy El (V agd/or D)
Private Well ❑ t6
Water Storage ElL)CC 2013
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
of property owner or authorized agent)
Permit/Rush Fees: Waiver Fees:
Date of Payment: /Z� 7�"3 Date of Payment:
Receipt Number: / 5�ry ,owos� Receipt Number:
Permit No. 65 P Ib 14�`( Waiver No.
permit App_9-1-12.doc
Environmental Consulting and Design
SEPTIC SYSTEM DESIGN
TIMBERLUX #1 BLOCK D LOT 4
Municipality of Anchorage December 16, 2013
Development Services Department
On Site Water and Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99519
Subject: Septic System Installation Permit Renewal
15320 Curvell Dr.
Ladies and Gentlemen:
I am writing to request a renewal of the septic system installation permit for the above referenced
property. The original permit application was submitted by Flattop Technical Services and
issued on August 13, 2009, permit # SW090149.
A site inspection was conducted on December 12th, 2013. Both test holes groiund water
monitors tubes were located. Ground water was observed at a depth of 7.5 feet in TH#1 and 9.5
feet in TH#2. The design as approved does not require any modifications.
If you have any questions or concerns, please contact me at 279-3916.
Sincerely,
ar purkland, P.E.
Civil Engineer
203 West 150h Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fag: (866) 354-1597, Lspurkland@gci.net
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 6 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Aug 13, 2009
Expiration Date: Aug 13, 2010
Permit Number: SWO90149 Parcel ID: 018-271-18
Legal Description: TIMBERLUX #1 BLK D LT 4
Design Engineer: 0019 FLATTOP TECHNICAL SERVICES Site Address: 015320 CURVELL DR
Owner Name: SCOTT POWELL Lot Size: 0 SO. FT.
Owner Address: POB 233252 Total Bedrooms: 0 Permit Bedrooms: 4
ANCHORAGE. AK 99523-0000
This permit is for the construction of:
❑-1 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Date: 61241 /'C"'9
Municipality of Anchorage
1.1 Development Services Department
Building Safety Division
On -Site Water and Wastewater Program `
4700 Elmore Road
P.O. Box 196650
Anchorage, Alaska 99507
www.muni.org/onsite
(907)343-7904
ON-SITE SEWERNVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. _ 01 & — 2 71 _ iF
Property owner(s)�-off Poc,,. p Day phone 2'rY-1997
Mailing address P•o. ea,i 23 2S Zip Code9952 ?
Site address /S3 20 ('ac r 4.N D ., { Zip Code
Legal description (Sub'd., Block & Lot) 1.4,1 y ls'/k `p� TS/ux # /
Legal description (Township, Range & Section)
Lot Size Sq. Ft.
Number of Bedrooms '7/
THIS APPLICATION IS FOR (0 all that apply):
THIS APPLICATION Is AN:
Absorption Field ®
Initial E3Septic
Tank ®
Upgrade 12
Holding Tank ❑
Renewal El
❑
Private Well ❑
Water Storage ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: S?,o Waiver Fees:
Date of Payment: S - / O — O Ci Date of Payment:
Receipt Number: _O 0 S_ cl q Ci Receipt Number.
(Rev. 11/05)
CML 6 ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS
TED MOORE, P.E. 14530 ECHO CANYON ROAD
PHJFAX: (907)345-1355 ANCHORAGE, AK 99516
E -Mail: tgmoore@gcl.net August 10, 2009
M.O.A. DSD
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide a design narrative in support of our application to upgrade the
wastewater disposal system serving the 4 -bedroom residence on Lot 4, Block "D", Timberlux S/D, Unit
# 1, located at 15320 Curvcll Drive. Soils logs, perc test results, a site plan, design drawings and
specifications are enclosed for your review.
As can be seen from the soils log for test hole 42, the native soil between 1.25 and 9.5 feet below ground
level is sandy gravel with a measured percolation rate of less than one minute per inch. Although no
groundwater was observed at the time the test hole was dug or during the ensuing week, relatively
shallow seasonal groundwater tables have been documented in the general area. According we propose
to construct a shallow bed -type absorption system with a two -foot thick sand filter to position the bottom
of the sewer gravel at a depth of 0.75 feet below original ground level.
Using a soil application rate of 0.7 gpd/sq. ft. as specified in the wastewater ordinance for filter sand, the
required absorption area for a 4 -bedroom residence is (4 x 150Y0.7 = 858 square feet. The proposed 15'
wide by 58' long soil absorption bed has a basal area of 870 square feet. The topography of the lot is
almost level, with about a 2% slope downwards towards the WNW.
In order to construct the system parallel to existing contours of the land and avoid conflict with an
existing shed, the south end of the absorption bed will extend into a platted 20 -foot wide "screening and
fencing easement". I discussed this configuration with Laura in the Municipal R.O.W. section and was
informed that such an easement is not a concern of theirs, so no R.O.W. easement would be required. I
also discussed this with Jeff Poet in your office and he concurred that there should not be any objection
to having a portion of the absorption bed extend into this easement.
According to Municipal records, the existing 1250 -gallon, single compartment, concrete septic tank was
installed in 1970 at a distance of approximately 90 feet from the well on the same lot. At that time the
required separation distance from a private well was 50 feet, so no waiver was or should be required for
continued use of the tank. A Municipal waiver was issued in 1992 allowing the more recent well on Lot
3 to be approved at a distance of 85 feet from this septic tank.
Since concrete tanks do not necessarily deteriorate rapidly with age, the property owner would prefer to
utilize this septic tank in conjunction with a new 500 -gallon lits station located outside the 100 -foot
protective radii of all wells. We propose to do so, providing an inspection of the tank conducted at the
time of bed construction reveals that the tank is still in sound condition, does not leak and has a
functional outlet baffle. If the existing septic tank is found to be no longer in acceptable condition, it
will be properly abandoned and replaced with a new 1500 -gallon STEP tank located more than 100 feet
from all wells.
The proposed system will have no significant impact on present or future water supply and wastewater
disposal systems serving adjacent properties, nor will it have any significant impact on reserved space -
surface and subsurface, or on drainage.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
rev l3?o-...c,
Ted Moore, P.E.
LOT 3
�\
CURVELLDRIVE — — — v - --�'
LOT 4, BLOCK "D"
TIMBERLUX #1
1 - ,
R = 100, WELL
V
, ` C
1 1
1 `♦ 1
1 •♦ 1
1 , 1
1 . 1
1
1,4-BDRMI
!HOUSE
R=100'
INSPECT Or ABANDON
EXISTING
CONCRETE TANK •i
INSTALL 500 -GAL. ,
LIFT STATION
or 1500 -GALLON
STEP TANK
CONSTRUCT 15' WIDE
x 58' LONG SOIL ABS. BED
m`
W. 0.8 GVL b 2.0 ISF SAND �—
T.H_T.H.
#2
r
---------------
20 SCREENING AND FENCING ESMT_ -----------
RABBR CREEK ROAD
FA
�.
9IH
#
......................
4 i
THEODORE F. MOORE
I_ CE -3589 1
L40fe
' N ♦'
I `
I
HOUSE
1
I I
I ,
I �
I
I '
WELL
I ,
I ,
I ,
LOT 5
I ,
I '
I .
,r
' SEPTIC
AREA
°
i
1.25" DIA. SCHED. 40 PVC
w 3/16" HOLES IN BOTTOM
SPACED 2' O.C.
-'---------------------
---------------
I
LOT 4, BLOCK "D", TIMBERLUX SID, ADD'N #1
SEPTIC SYSTEM UPGRADE
SITE PLAN
FLATTOP TECI INICAL SERVICES
1 INCH= 50 FEET
14530 ECI10 CANYON ROAD
DRAWN BY TFM
1
ANCI IORAGE, ALASKA'
WELD
I
W
I
f(un,
i ek
I
I
I
ci
CURVELLDRIVE — — — v - --�'
LOT 4, BLOCK "D"
TIMBERLUX #1
1 - ,
R = 100, WELL
V
, ` C
1 1
1 `♦ 1
1 •♦ 1
1 , 1
1 . 1
1
1,4-BDRMI
!HOUSE
R=100'
INSPECT Or ABANDON
EXISTING
CONCRETE TANK •i
INSTALL 500 -GAL. ,
LIFT STATION
or 1500 -GALLON
STEP TANK
CONSTRUCT 15' WIDE
x 58' LONG SOIL ABS. BED
m`
W. 0.8 GVL b 2.0 ISF SAND �—
T.H_T.H.
#2
r
---------------
20 SCREENING AND FENCING ESMT_ -----------
RABBR CREEK ROAD
FA
�.
9IH
#
......................
4 i
THEODORE F. MOORE
I_ CE -3589 1
L40fe
' N ♦'
I `
I
HOUSE
1
I I
I ,
I �
I
I '
WELL
I ,
I ,
I ,
LOT 5
I ,
I '
I .
,r
' SEPTIC
AREA
°
i
1.25" DIA. SCHED. 40 PVC
w 3/16" HOLES IN BOTTOM
SPACED 2' O.C.
-'---------------------
---------------
I
LOT 4, BLOCK "D", TIMBERLUX SID, ADD'N #1
SEPTIC SYSTEM UPGRADE
SITE PLAN
FLATTOP TECI INICAL SERVICES
1 INCH= 50 FEET
14530 ECI10 CANYON ROAD
DRAWN BY TFM
1
ANCI IORAGE, ALASKA'
AUGUST, 2005
NOTE: THIS IS NOT A SURVEYED PLAT.
ARE
2.5
5
15
5
2.5
1.25" DIA. SCHED. 40 PVC
..A. w 3116" HOLES IN BOTTOMS
58 SPACED 2.0' ON CENTER
....... ..................
...
.....5
. . . ..
O M.T.1
.................. . , .
, .......... _..
„ ............
O
M. T.!.
4' D-3034 FROM NEW
FDN. C.O.OR EXISTING "A"
Llw-
SEPTIC TANK
NEW 1500 -GALLON
STEP TANK (OR 500
GALLON LIFT TANK
(d existing concrete tank
found to be in good shape)
1.25" DIA. HDPE
OR SCHED. 40 PVC
PLAN VIEW
SCALE 1" = 10'
MONITOR TUBE
3
2.5 5
ORIGINAL GROUND _/ 2.8 I 2 .11 y,0' ISF FILTER SAND -
NATIVE GRAVEL 15
CROSS-SECTION "A -All
SCALE: 1" = 5'
15' -WIDE x 58' LONG SOIL ABS. BED
w. 0.8' WASHED GRAVEL 8 2.0' ISF
SAND UNDER DISTRIBUTION PIPES
AV
AV
49 m � it
........................
j
p : THEOOORE F. IIOORE i
., CE -3589 �A
1
ere ••.••• ��� , \ qb',E?ofe ss 10
SOIL COVER
RIGID INSULATION
5 , 2.5
FILTER FABRIC
0.8' WASHED
SEWER GRAVEL
1.25" DIA. SCHED. 40 PVC
w 3116" DIA. HOLES @ 2.0'
LOT 4, BLOCK "D", TIMBERLUX S/D # 1
SEPTIC SYSTEM UPGRADE
_ PLAN AND CROSS-SECTION
FLATTOP TECHNICAL SERVICESSCALD: AS SI [OWN
14510 ECI10 CANYON ROAD DRAWN BY: TFM
ANCI IORAGE, AK, 99516 AUGUST. 2009
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
TEST HOLE # 2 SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION:
_Lot 4,, Block •Di_Thmbedux SID
DATE PERFORMED: _July
28, 2009
PERFORMED FOR: _-Scott
Powell_
DEPT
(feet:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
17
18
19
VES
PL
SM Reddish sandy Wm
GP Clean, slightly silty sandy gravel
Dry
GP/GM Somewhat silty sandy gravel
Dry, thin lenses of SM
SM Bmwn/Blue sand
w. roots 8 sticks
B.H.
SLOPE
1%
Depth to Groundwater Date
_No Groundwater- 7128/09
_Monitor tube dry, 8/6/09-
-- -----_�-1-_�
QuoOF ®� A
Lip �• N1111111 "y
AOTHL�#A
��. 1/1/1 • • 111111111�1C`1.11•/1/1�/1'(Z 1�M
.}1/%"4ir'}1: •.1111 �1rrt
®it�1 �. HEODORE F. LIOCRE:
SITE PLAN
Date
_
Reading
Clock
Time
N
(m
7/27_
5-gallonpresoak-
.----#2 _
_11:34:20 __
1135:20
_
-
_
-
_
_11:36:20
11:36:40-
-
_—
_2nd 5-gallogs6ak-_
-11:40 -
--
-
-
--
- #1
_ #2
11:41 _1
1;42
--
--
--#3 —
-11:43 —
-
-11:43:30
-
---__--
i
LOT 4 BLOCK -W
T ABERLUX H
T.H:
#1
Ne
Time
inutes)
7 ..
1.
0.33
2%
Percometer
Net Drop
Reading
(inches)
--
- ---
_-_2E
21 3/8
—46/8-
5/8_18
--- 1
3518
-_163!4 _
= dry =.
--21.1/4
31/4-
-31/4-
83/8_
83/8_
27/8
63/4 --dry
PERCOLATION RATE
«1—
(minutesMch)
PERC HOLE DIAMETER 8
TEST RUN BETWEEN_2.25-FT
AND _2.75_-,
FT
COMMENTS:
PERFORMED BY FLATTOP TECHNICAL SERVICES. I _TAy,P eoplj� CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 6 /!O / 09
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
TEST HOLE # 1 SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: —Lot 4, Block'D',TlmbedUx SID
DATE PERFORMED: __July 28,.2009 -
PERFORMED FOR:
-.__Scott Powell _
DEPTH
PL
(feet)
Net Drop
(mches)
1 -
SM Reddish sandy loam
2-
GP Clean sandy gravel
3 -
SM Silty fine sand
4-
Damp, w. streaks
5-
-6-
6-
GP Sandy gravel
Dry
7-
e -
SM Brown/Blue silty sand
9
Damp, cohesive, w. old sticks
10"
GP/GM Somewhat silty Depth to Groundwater
11 + B.H. Gravel —No Gri
_Monitc
12 ---
13-
14
3-14 =
15-
16 -i
I
17
18 j
I
i
20-1 I
SITE PLAN
LOT 413LOCK'V
TIYBERLUX H
1%
T.H:
Date
NmN
48
54
T.N. i
#2 I
2%
Date
Reading
Clock
Time
Net Time
(minutes)
Percometer
Reading
Net Drop
(mches)
PERCOLATION RATE (minuteslmch) PERC HOLE DIAMETER -
TEST RUN BETWEEN FT AND FT
COMMENTS: -._-No percolation. test conducted because even better soils encountered in test hole #2.
PERFORMED BY FLATTOP TECHNICAL SERVICES. I_ J� %%Sp.a„L CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: B //O /09
e'fattop 7ecfinicalSemj=
14530 rF.cho Canyon 4jpa4 Anchorage, AX 99S16
Thone (907) 345-1355
Lot 4, Block "D", Timberlux S/D, Addition #1
15320 Curvell Drive
Wastewater disposal system
Specifications
1.0 General:
1.1 The scope of the project consists of inspecting an existing concrete septic tank and installing
either a 500 -gallon lift station or a new 1500 -gallon STEP tank that pumps effluent up into a new 15 -
foot wide by 58 -foot long soil absorption bed with 0.5 feet of washed sewer gravel and 2.0 feet of ISF
filter sand under the distribution pipes.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived. Prior to the start of construction the contractor shall arrangefor a land surveyor
to place survey laths to delineate the 100 -foot well radii for the Lot 4 and Lot 3 wells in the vicinity of
the existing septic tank and proposed STEP tank. The surveyor should also place survey laths at the
southeast corner of the lot and at 50' and 100' divtances from that corner along the south and east lot
lines.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work
around any buried utilities.
1.4 Unless agreed otherwise, the contractor shall be responsible for any tree clearing and
grubbing necessary to complete the project.
1.5 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.6 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, and seeding all areas disturbed by the construction.
2.0 Tanks:
2.1 The existing concrete septic tank shall be exposed to allow the engineer to inspect its
condition and to check for possible leakage around seams and to verify the condition of its outlet baffle.
If the tank is found to be in unsatisfactory condition it shall be properly abandoned per code by pumping
and backfilling with soil. The existing log crib seepage pit shall be properly abandoned per code.
2.2 If the existing tank is found to be in good condition with a functional outlet baffle, the
contractor shall install a new 500 -gallon, Municipally approved lift station outside the 100 -foot radius
around the well. if the existing septic tank is not in good condition it shall be properly abandoned and
replaced with anew Municipally approved 1500 -gallon STEP tank located outside the 100 -foot radius
around all wells. All tanks that are buried less than 4 feet shall be insulated with 2 inches of approved
burial type, rigid insulation.
2.3 All pipe connections to the tanks shall be equipped with waterproof mechanical couplings.
The waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot. A
foundation cleanout shall be installed within 4 feet of the building foundation, or a double cleanout
installed upstream of the septic tank.
2.4 The lift station shall be installed either in the separate 500 -gallon tank or in the second
compartment of the STEP tank. The lift station package shall be an "Orenco' system as supplied by
Anchorage Tank.
2.5 The contractor shall be responsible to obtain the necessary Municipal electric permit and
inspection, and shall provide a copy of the electrical inspector's report to the engineer overseeing the
construction of the wastewater disposal system.
2.6 The lift station shall be equipped with a watertight, insulated manhole riser and cover
extending a minimum of 6" above final grade with positive surface drainage away from the manhole.
The contractor shall be responsible for determining the necessary length of the manhole riser.
2.7 The on, off, and alarm floats shall be set at the elevations specified by the lift station
supplier, and their proper operations shall be verified by the contractor.
2.8 The discharge line from the lift station to the soil absorption system shall be 1.25" dia.
Sched 40 PVC or IIDPE.
3.0 Soil absorption system:
3.1 The soil absorption bed shall be constructed by excavating a 15 -foot wide by 58 -foot long
excavation to a depth of 2.8 feet below ground level on the uphill side of the bed.
3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be
raked to allow proper infiltration.
3.3 A total of 2.0 feet of ISF filter sand (with less than 2% passing the #100 sieve and 1%
passing the #200 sieve) shall be placed in the excavation and compacted by foot to create a level surface
at the level of the original ground at the location of the test hole monitor tube.
3.4 Next, a total of 0.8 feet of washed sewer gravel shall be placed on top of the sand with the
perforated distribution pipes laid level such that the pipe inverts are no less than 0.5 feet above the
bottom of the sewer gravel.
3.4 The distribution pipes shall be 1.25" diameter schedule 40 PVC with 3/16" holes drilled in
the bottoms at 2.0' spacing. Monitor tubes shall be of 4" diameter and installed in the locations shown
on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. Two
inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition
to the filter fabric.
3.6 Two feet of soil cover material shall be placed above the top of the insulation, of which the
top six inches is to be topsoil. Fill slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to
have the site finish graded after the backfill material has stabilized, and for placement of adequate seed
to promote rapid revegetation.
4.0 Inspections:
4.1 A total of 5 engineering inspections will be required during the course of the project: (1)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the compacted sand filter material has been placed, (4) after the sewer gravel is in
place and the distribution pipes have been laid and connected up to the STEP tank, but prior to
placement of insulation or filter fabric, and (5) after rough backfill and grading is complete. The septic
tank and STEP tank installation inspection shall be in conjunction with one of the other listed
inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far
in advance to ensure the availability of the engineer.
GREAtcR
r�
ANCHORAGE AREA BORL,JGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
r. INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM /�_ .. /2
qpiiiiiii i i _ . 0LS!H
I // - % / I C?trft--C-�� ✓J . / 12fAy .
11 -CV . LEGAL DESCRIPTION
SEPTIC TANK:,,
DISTANCE -1,a�" / NUMBER OF
q
FROM WELL _L— MANUFACTURER__QA-d51MATERIAL COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY 2-5:_7J GALLONS.
SEEPAGET:�%A2C� I / O h
NUMBER OF PITS --L—. DIAMETER —OR WIDTH L, LENGTHS DEPTH
/f ;E7
LINING MATERIAL /tiP�PJ'� CRIB SIZE: DIAMETER _DEPTH_DlSTANCE FROM: WELL.
TOTAL EFFECTIVE S
BUILDING FOUNDATION_, NEAREST LOT LINE . ABSORPTION AREA (WALL AREA) SQ. FT.
ADDITIONAL ABSORPTION
WELL:
Ir
TYPE v CONSTRUCTION
BUILDING NEAREST
FOUNDATION LOT LINE
CESSPOOL , OTHER SOURCES
APPROVED DISAPPROVED
DISTANCES:
INSTALLED BY: 50" —"
PIPE MATERIAL:
LOT SLOPE: _
REMARKS:
DEPTH
NEAREST SEPTIC
SEWER LINE , TANKS,
REMA
DISTANCE FROM:
SEEPAGE
SYSTEM lig
DIAGVtAM OF SYSTEM
DATE �t,V 15,0 APPROVED .• • •-�x�
A.A.B.
yam No. EQ -031
0
GREATER A CHORAGAREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330"C"STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4581
�o' OPM
PERMIT NO.
/ 3°
SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT
LEGAL DESCRIPTION
INSTALLATION OF: SEPTIC TANK SEEPAGE PIT
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
BOIL TEST RESULTS
COMPLETION DATE ANTICIPATED
TO BE INSTALLED BY
OTHER
NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE
TYPE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
�f
SEiFAGG-AMeT SIZE
��GLI
FOUNDATION TO SEEPAGE PIT f/0
„ DRAIN FIELD
-%%L "cj'—t^
SEPTIC TANK TO SLSP*6==FWALL /'
SEPTIC TANK4[EPAZih TS` `7 , DRRIN-FTELD'
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK /-SEEPAGS-PiT
DRA -FIELD ALSO CONSIDER AREA WELLS.
WAFSR-MAIN-M?EPTtCTAWK SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK, 06 I SEEPAGE PIT 0O /DRAIN FIELD 1661 00/
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. INSTA✓LL-ATION. `
/ll!7/G/�-tom /�Fi�✓,Uli%O C"I,
G.A.A.B.
OR
LICENSED DESIGNER -
1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE,
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE 8 f /D/7 APPLICANT'S SIGNATURE 14
FORM NO. EQ -019
TYPE
DIAGRAM OF SYSTEM
�' '
?b' i�nR
"77_5
NAME OF APPLICANT
MAILING ADDRESS .545 PHONE
INSTALLATION LOCATION
LEGAL DESCRIPTION
INSTALLATION OF: SEPTIC TANK SEEPAGE PIT
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
BOIL TEST RESULTS
COMPLETION DATE ANTICIPATED
TO BE INSTALLED BY
OTHER
NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE
TYPE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
�f
SEiFAGG-AMeT SIZE
��GLI
FOUNDATION TO SEEPAGE PIT f/0
„ DRAIN FIELD
-%%L "cj'—t^
SEPTIC TANK TO SLSP*6==FWALL /'
SEPTIC TANK4[EPAZih TS` `7 , DRRIN-FTELD'
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK /-SEEPAGS-PiT
DRA -FIELD ALSO CONSIDER AREA WELLS.
WAFSR-MAIN-M?EPTtCTAWK SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK, 06 I SEEPAGE PIT 0O /DRAIN FIELD 1661 00/
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. INSTA✓LL-ATION. `
/ll!7/G/�-tom /�Fi�✓,Uli%O C"I,
G.A.A.B.
OR
LICENSED DESIGNER -
1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE,
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE 8 f /D/7 APPLICANT'S SIGNATURE 14
FORM NO. EQ -019
TYPE
DIAGRAM OF SYSTEM
GAAB-HDI �' G�FATER ANCHORAGE AREA BOROUGH
HEALTH DEPARTMENT
/ 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
MAILINGNAME �� �J `I��f Lam` ADDRESS // U� S�—PHONEE 7a 3a
LOCATION P1/1SL'I! .LEGAL DESCRIPTION 107-'// 151t� 1/�%l/SC'���%�X
SEPTIC TANK:
�`� / `��L+xG'�-ry NUMBER OF pnvr'1
DISTANCE FROM WELL ^ MATERIAL 111---Cl4 G/, COMPARTME TS
/ aSv 5v&-17t� LIQUID
LIQUID CAPACITY GALLONS. INSIDE LENGTH INSIDE WIDTH DEPTH
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS / OUTSIDE DIAMETER OR WIDTH , LENGTH 2, DEPTH
LINING MATERIAL IBJ �TS . DISTANCE FROM WELL <, / , BUILDING FOUNDATION 1c'
/
NEAREST LOT LINE ' TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) v c
9 SO. FT.
TILE DRAIN FIELD:
TOTAL LENGTH
DISTANCE FROM WELL , FO , NEAREST LOT LINE . OF LINES ,
NUMBER O LINES STANCE BETWEEN LINES TRENCH WI IN. TOTAL EFFECTIVE
ABSORPTION ARE SO. FT. LENGTH OF EACH LINE
DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE
WELL;"/T% " `i7 C'/«� 'i DISTANCE FROM / WATER
TYPE DEPTH ,BUILDING FOUNDATION. I f- SAMPLE NEAREST
NEAREST SEPTIC C / SEEPAGE / OTHER
LOT LINE f'�'" • SEWER LINE rd� ,TANK •� , SYSTEM �f , CESSPOOL - , SOURCES_
DIAGRAM OF SYSTEM
DISTANCES: ;
� I �
I
I i 1
DATE �1
GAAB-}(D•2 GREATEN ANCHORAGE AREA("1OROUGH
IIEALTII DEPARTMENT
327 Eagle St. Anchorage, Alaska 99501
279-2511
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
� W_
NAME OF APPLICANi��o 1426— hAILING ADDRESSZ10 /SPHONt7 %S3S RESIDENCE ADDRESS LOCATION OF INSTALLATION fI/-SLitT CERf
LEGAL DESCRIPTIO
APPLICATION TO INSTALL: SEPTIC
TO SERVE THE FOLLOWING FACILITY
FINANCED THROUGH_/
-7o/L
P#,TEST RESULTS
SEEPAGE PIT_ , DRAIN FIELD , OTHER
TO BE INSTALLED BY
ANTICIPATED DATE OF COMPLETION -2 y 11Z- /V/C774r,&—
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS ". (_Izzzo—�_ -, PERMIT TO INSTALL A 5:571r -702r, ;%ys
AS DESCRIBED BELOW. SIZE OFUNTO BE SERVED — J �C21f• //r 16
SEPTIC TANK SIZE TYPE OCA(J . SEEPAGE AREA VC/LTYPE
DIAGRAM OF SYSTEM
DISTANCES: �Qi11/`�1�(/Yj�
�V&V o
JSCJ�r1c /f1/�� = Sa!
'74 t
s
HEALTH AVTHORITY
OR
LICENSED DESIGNER
I certify that I am familiar with the requirements of Greater Anchorage Area Borough
above described sys em is in accordance with
DATE O
said code.
APPLICANTS SIGNATU
(ante No. 28-68 and that the
?' OO/4 ?trT
n GREATER ANCHORASE AREA. P.OROUG1-^1
• HEALTH DEPARTMENT CASE A
327 EAGLE STREET
ANCHORAGE, ALASKA 99501
Performed For ,r rre, i�rnrrrp Date Performed — c
Legal Description: Lo y nlock�_Subdivision (; mak A
This Fort,- Re-orts a: Soils LOP ,/ Percolation Fest
Depth
Feet Soil Charatteristies Location Sketch
t1e. betfom he le:
sedimenfs represPnf av:
Gncten f 4op soil f ho f
has becy% buried Gy
cllat101 depcslls. 1 a5siyrted
t 1 a vn l u e, el a 7S"—'/bckm
Sim;lar }v fh't C1 M{-.
,qll shalt. had #-ela4i,:03
Sharp boundries. Fq f
inier4c4 a tt 1 there was
Ah Pt}rernely high mcisfure.
tcnleni almest to be
Ccnsidareb o, wt,ter f-a61e.
SCme tuct4Pr wes leauiny
}he sedimenf6 ai fhis
IOcu 1,'011 eu f t h,Y was
0-f c' minor amcUn'f`,
Sf
Was Ground Plater Encountered?jUn � o
A�
re arl(s�
If Yes, At What Depth
Proposed Installatjon; Seepage Pi
Depth Of Inlet u..c ne
Test Performed By: Pprre r
Data Certified By:
Date I / {--Z�19
1
N
,10'�
N
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received September 13, 1976
Time of Inspection k:30 p.m.
Date of Inspection 9-14-76 Tuesday
REQUEST FOR APPROVAL OF Pratt
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Con v.
1. Approval requested by: Alaska National Bank ,p�(..Y1c_-
Mailing Address: Pouch 7010 Phone: 277-5511 x 31
2. Property Owner: Jerry D. Crowe & Frankie C. Phone: non -working
Mailing Address: Curvell Drive
3. Legal Description: Lot 4 Block D Timberlux Subdivision
4. Location: Rabbit Creek to Longbow Drive, left on Curvell Drive
5. Type of facility to be inspected Single Family No. of bedrooms 3
6. Well Data: Individual
A. Type B. Depth
C. Construction D. Bacterial Analysis
7. Sewage Disposal System: On-site system, upgraded 1976
A. Installed B. Installer
C. Septic Tank: 1. Size 2. Manufacturer
D. Seepage Pit: 1. Absorption Area 2. Material
E. Disposal Field: Total length of lines
8. Distances:
A. Well to: Septic tank , Absorption area Sewer Lines
Nearest lot line Other contamination
B. Foundation to septic tank Absorption area
C. Absorption area to nearest lot line
EQ -034 (1/74)
Page 1 of two pages
Page 2 of two pages - Req At for Approval of Individual S�';r & Water Facilities
Legal Description
Comments
Approved
Lot 4 Block D TimberlAx Subdivision N1
Disapproved
Date
Approval,Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
EQ -034 (1/74)
Date
n
'GREATER ANCHORAGE ARIA BOROUGH
Department of Environmental Quality
Y' cr r�
3330 "C" St., Anchorage, Alaska 99503 - 274-4561
OF
INDIVIDUALS SEWER &FORPWATERLFACILITIES R E C EIL/E:��
1.
Type of Inspection:•
CMRO VA
FHA =V xx
2.
Property Owner:
CROWE, Jerry D. and Frankie C.
Location: Rabbit
Creeek
Road
to Longbow Drive .
Left
Mailing Address:
Unknown (Curvell Drive)
Day Phone Disconnected
3.
Name of Buyer: BAILEY, BERT R. and BONNIE J.
Mailing Address:
4325 MacAlister Drive
Day Phone 344-6810
4.
Name of Lending Institution:
Alaska National
Bank
Mailing Address:
Pouch 7-010
Phone 277-5511 Ext. 31
5.
Name of,Realtor or
Agent: Eugene W. Bates
Tast Realty
Mailing Address:
3050 Lake Shore Drive
Phone 274-5676
6.
Legal Description:
Lot 4,
Block
"D", Timberlux S/D
Add.
O1
Location: Rabbit
Creeek
Road
to Longbow Drive .
Left
on Curvell Drive.
7. .Type of Facility to be inspected: Single family No. Bdrms. 3
8. Water Supply
Type of Supply: Public Utility Individual xx
If Individual, number of dwellings presently served Unknown
If.Individual, depth of well Unknown .
9. Sewage Disposal -System
Type.of System:. Public Utility Individual (on-site) Ix
If Individual, date of installation Unknown
®r. GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
J3330 Street, Anchorage, Alaska 99503 274-4561
• Yt Date Received May 28, 1976
\ Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Conv.
1. Approval requested by: Peoples Bank and Trust
Mailing Address: 644 West 8th Avenue
3:00 p.m.
6-1-76 Tuesday
Les Buchholz
Phone: 279-7511
2. Property Owner: Jerry Crowe Phone: 505-988-6560
3.
4
Mailing Address: Post Office Box 2348, Santa Fe, New Mexico
Legal Description: Lot 4 Block D Timberlux Subdivision
Location: Rabbit Creek Road
5. Type of facility to be inspected Single Family
6.
Well Data:
A. Type Individual
C. Construction
B. Depth
87501
No. of bedrooms 5
D. Bacterial Analysis
7. Sewage Disposal System: On—site system
A. Installed 1970 B. Installer
C. Septic Tank: 1. Size
D. Seepage Pit: 1. Absorption Area
E. Disposal Field: Total length of lines
8. Distances:
2. Manufacturer
2. Material
A. Well to: Septic tank , Absorption area Sewer Lines
Nearest lot line Other contamination
B. Foundation to septic tank Absorption area
C. Absorption area to nearest lot line
EQ -034 (1/74) Page 1 of two pages
s Page 2 of two pages - Re ^st for Approval of Individual '"ler & Water Facilities
'Legal Description Lot 4 Block D Timberlux Subdivision
Comments
Approved
Disapproved
Date
Approval,Valid for one year from date sj[g ed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
'/ C��rluq
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
EQ -034 (1/74)
Date
•- ���� MUNICIPALITY OF ANCHOPAO-c
^ DEPT. OF HEP.LhI ..
l CQ�ri,CI JI'I" ENVOONMENTAL P:C%CTION
oit-
GREATER
MAY 23.0x1976 v,
ANCHORAGE AREA BOROUGHpECEIU_.EQ Department of Environmental Quality _
3330 "C" St., Anchorage, Alaska 99503 --244-45-61
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA FHA CONV t/
2. Property Owner: Jorra O fe'
PO..6a3Nd' 8�so/
Mailing Address:—,la22n Of-, d&_4w L�G' z� o Day Phone .5'0r- 4,566
3. Name of Buyer: WA fer F d- 112 A r Dnin'for tl,
Mailing Address: e,7la?G 6rrr// ' ket. Day Phone .3 i7-/9h'L
4. Name of Lending Institution: _P0r.nlo's gn-nlf C1 Tru_-)
Mailing Address: 6 -w &c ',rA Ove- _Phone o? 7 j- 7T11
5. Name of Realtor or Agent: -)rrl, fi ss rr 0brtNin
Mailing Address: �� L-. Firtl_t Fr/� h-ojtc, Phone _2j-2-r-71 Cl'Q.0
707'05"Pr &rj,37')L r%w 3'V-a9/'O
6. Legal Description: 11 / / b,1-AL�! S',. 64
Location: 0f� t1�C�G�IcE eatt_L' trail, )4twn cn
nn ° rc. w /n fti
/?Ytmt•c�lItc
J--j
7. Type of Facility to be inspected: S1iduNo. Bdrms.
8. Water Supply
Type of Supply: Public Utility Individual
If Individual, number of dwellings presently served _
If Individual, depth of well T
9. Sewage Disposal System
Type.of System: Public Utility Individual (on-site) v
If Individual, date of installation 19740
EQ -037 (1/74)
I
June 2, 1975
4.1
Totem Realty
I Barb Bliss
'515 bast Fireweed Lane
Anchorage, Alaska 99503
Subjecti Lot 4 Block D Timberlux subdivision
Dear He. Bliss:
The seepage pit at the time of inspection was within four
(4) toot of the ground surface. N, new absorpiton area is
requested before an approval can be granted by this
department.
The septic tank must be pumped for =aintenaace purposes.
The well is approved construction.
A new absorption tronch consisting the following specifications,
Depth 9.5 feet
Gravel depth 4.5 feet
Length S$U"t
A permit is required from this office. A copy of this letter
at the time pf permit applicatica would bo helpful.
if you have any further ". astions, please contact this office
at 27G-2221, extension 285.
sincerely,
Los V. Buchhola
Sanitarian,
LaZ/ljh
Municipality of Anchorag MAR
• / J 1
On -Site Water and Wastewater Program
--'`t (907)343-7904 -reek `dam
Certificate of On -Site Systems Approval P /
Parcel I.D. 018-271-18 Expiration Date: (0 —�cO
1. GENERAL INFORMATION
Complete legal description Timberlux #1; Block D, Lot 4
Location (site address) 15320 Curvell drive *Anchorage 99516
Current Property owner(s) Lorna Findley Day phone 303-818-0717
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: A J
4. TYPE OF WATER SUPPLY:
Individual Well
19
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
Waiver/Variance request for: NIA
Received by:
COSA to be relea
Day phone
TYPE OF WASTEWATER DISPOSAL
Individual
19
Holding Tank
❑
Community
❑
Public Sewer
❑
the e�eer, unless otherwise requested by the engineer.
COSA Fee $ 4yto l
Date of Payment 212,r 114,
Receipt Number ilri,, -
COSA# 65oi 162 to
Date:
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Garness Engineering Group, Ltd. (GEG) Phone (907) 337-6179
Address 3701 E. Tudor Road, Suite 101, Anchorage AK 99507-1259
Engineer's Printed Name Jeffrey A. Garness Date ,?dr e /16
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic
system in accordance with the guidelines and regulations established by the Municipality of
Anchorage and industry practices. The reported results describe the condition of the systems on the
date/s of the evaluation. Separation distances were measured to readily identifiable features.
Hidden defects or encroachments may exist that were not identified during the evaluation. The
operational life of all wells and septic systems depend on a variety of variables including, but not
limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of
construction (materials and workmanship), and the water usage of the family utilizing the system/s.
These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future performance of the system/s; therefore, GEG makes no warranty (express or
implied) regarding the future performance of the well or septic system. GEG makes no
representation whether an alternative well or septic system can be installed on the property in the
event either of the current systems fail. The content of this report is for the sole benefit of the
person1party who retained GEG. Reliance upon the information provided in this report by any other
person or party, including but not limited to subsequent property purchasers, is not authorized. In
short, GEG disavows any legal duty to anyone other than the person/party who paid for this report.
6. DSD SIGNATURE
0
System #1 Approved for bedrooms
System #2 Approved for bedrooms �Y OF,11V
Disapproved �O 5p .,
Conditional approval for bedrooms, with the following stip doSON-SITE ��'•,
CVATER AND r":
Original Certificate Date: - —_?, 2 ^ I
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
COSA Nue sheet 9-1-12.doc
Nitrate Advisory
Arsenic Advisory
Other
N more than 1 septic system is on the lot:
COSA Checklist # _of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description:
A. WELL DATA
TIMBERLUX #1; BLOCK D, LOI 4 Parcel ID: 018-271-18
*ASSUMED PER YEAR BUILT HOUSE AND ORIGINAL SEPTIC INSTALLATION DATE
**PER GEG INSPECTION ***ASSUMED PER SURROUNDING WELL LOGS - SEE ATTACHED
Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO
Date completed *1970 Sanitary seal (YIN) YES Wires properly protected (Y/N) All Y�
Total depth **45+ ft. Cased to ***40+ ft. Casing height (above ground) 12+ in.
FROM WELL LOG AT INSPECTION
Date of test 2/19/16
00
Static water level_ L ft. 31.1 ft,
N
Well production g.p.m. 2.2+ 9;p,m,
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mi. Nitrate 0.612 mg./L. Collected by: GEG. Ltd.
Arsenic: JI D ug./L. Date of sample: 2/18/16
B. SEPTIC/HOLDING TANK DATA *DOUBLE CLEANOUTS BEFORE TANK
TankType/Material SEPTIC/CONCRETE Date installed 5/20/70
Tank size 1250 gal Number of Compartments 1 Cleanouts (YIN) YES
Foundation cleanout (Y/N) *NO Depression over tank (Y/N) NO Hi h water alarm (Y/N) YES
Date of pumping a- 1 (O Pumper MC.CLY)OJ(
C. ABSORPTION FIELD DATA eELow exrsnNc cRAOE
Date installed - 2/5/14 Soil rating (g.p.d./Worq/bdo 0_7 System type BED
Length'
58 ft. Width 15 ft. Gravel below pipe 0.5 g,
Total depth --ti-41—ft. Eff. absorption area8�0 fe Monitoring tube YES Depression Qver field . NO
Date of adequacy test 2/19/16 Results (PaSS/Fail) PASS Fo.r- ` bedrooms
Fluid depth In absorption field before test E in. Watef added 501 gal. New depth E in.
Elapsed Time: E min. Final fluid depth E in. Absorption rate >= 4+450+ g,p.d_
Any reluvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date -
PER 2014 INSPECTION REPORT BY LARS SPURKLAND, P.E. 2" INSULATION OVER DRAINFIELD.
3�0-
*PER 2014 INSPECTION REPORTs s o
D. LIFT STATION THERE IS AN INTERIOR ALARM INSIDE ^ fie+ G F•G, TdSP°L�iO
Date installed 2/5/14 Size in gallons 500 . Manhole/Access (Y/N) YES
"Pump on" level at 75 in. "Pump off" level at 78 in. High water alarm level at 71
Datum TOP OF MANHOLE Cycles tested 3 Meets alarm & circuit requirements? *YES
E.. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot *50'+/100'+ On adjacent lots 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main 75'+ Public sewer manhole/cleanout 100'+
Sewer /septic service line 25'+ Holding tank 75'+
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption
:9
Water main 25'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+.
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
*50'+ TO 1970 SEPTIC TANK 100'+ TO 2014 LIFT STATION
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSH guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date 3) 1 I'l lb
(Rev. 11/05)
t
GARNESS ENGINEERING GROUP Ltdn - oe
. l
CIVIL&ENVIRONMENTAL ENGINEERS �::�� _-- �.----- _
March 22, 2016
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Timberlux #1; Block D, Lot 4 - Request COSA Approval for 4 Bedrooms
To whom it may concern:
I am writing this letter in regards to 15320 Curvell Drive Anchorage, AK (Timberlux #1;
Block D, Lot 4). Per the request of the agent, the system was originally inspected and
tested for 3 bedrooms. The home was confirmed by Anchorage Live to be a 3 bedroom
house. However, per MOA records, an appraisal of the home, and your staff the home is
actually 4 bedrooms. We are requesting your department issue the COSA as a 4 bedroom
approval to reflect the actual sizing of the septic system and house. Per MOA records,
the septic system is sized for 4 bedrooms. During our inspection/test, five -hundred and
one (501) gallons of water was introduced into the system over a period of 210 minutes,
causing no rise in the monitoring tube. Based upon this data, it is apparent that if an
additional ninety-nine (99) gallons of water were introduced the system would have been
capable of absorbing it. This would have resulted in a 4 bedroom passed test. It should
be noted that elevation shots were taken and the monitoring tube was shown to be at an
elevation of 101.7. Per the 2014 inspection report the bottom of the system elevation was
101.8. In short, the MT goes slightly below the bottom of the effective and still remained
dry throughout the test.
We understand that your department only considers these requests on a case-by-case
basis and is not something that your department will typically allow.
If you have any quos ions please call me at 337-6179.
E.. M. S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338.3246 * Website: www.garnessengineering.com
GuY� it '•
,o
,
m N
t`n
N
-3-
M
O
Sca /e:
l'r= 30'
�i�
8/63 R
/90.00
48°
N
j W/Dayl;yh�smf�
J
'"'36�TIL
t VEWT3
SEPn�t+�K�
6/° w
Ch.O HH
,a
V
34 f
1
W
O
20' Sc✓een h9 Fenc (Piq F-
10
10 `,Ute
4O "p187,72 NO CORNERS SET THIS DATE
EASEMENTS OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PLAT ARE NOf SHOWN HEREON. DOW L
�ta
r
0
I hereby certify that I have performed a Mortgagee's inspection
of the following described propertrv: �-o f4 /C" k
72 lb ev/u X .sub AGI H /VO l '
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines and
do not overlap or encroach on the property lying adjacent thereto,
that no improvements on property lying adjacent thereto
encroach on the premises in question and that there are no
roadways, transmission lines or other visible easements on said
property except as indicated hereon.
Dated at Anchorae, Alaska
this day of _ ✓a n . _,s U6
FRED WALATKA & ASSOCIATES
(907) 248.7666 Engineers and Surveyors
c
0
MUNICIPALITY OF ANCHORAGE jai
DEPARTMENT OF HEALTH li HUMAN SERVICES IkMa
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 •Anchorage,Alaska 99519-6650
_ .... - 343-4744
CERTIFICATE OF HEALTH AUTHORITY,
t.
APPROVAL FOR A SINGLE FAMILY DWELLING
fl Parcel I.D. # 0 I'S ^ 1-71 1 Y . _ - HAA ri 4i Q°1ifl �d l Lo
it
1 GENERAL INFORMATION --- v _ •?.. ..
-- Complete legal description Lot 4; Btock D: 7cm6entuz •Subdiv.isicn 01
• 15320 Cu2vett D2ive
Location (site address or directions,
"-Anchotag¢. 'AK
1• . \BQJLt b Bonnie Baeteu "
Pr9pe_rtyowner Day phone -
349 2685
+. Mailing address T5320 CunveLt Drive Anehonaae.' AK 99516
- 'kLending gency _ Day phone
Mailmgaddress --
- • • Agent Day phone
.:Address
r I' V`. v. .v,rsTl StM M, -i�,F ?' r4 , :. a w /. .! a _ r r 'a^ rf4t.' . '! ♦ . ', r r v'..' :.
� , ; ,_:,n.—,.U JF....I p', 'i Ir ♦: ...,r ,.. .. . 1 , .. % .: r „ � r, l is
'ti 4`Unlesjs.
otherwise requested HAA will be held for pickup' �:' t�*i-,`} t ti' °f+ , �; �,: � gt �• u,•,
w A luY L:i,l �,, ♦ ♦ r h1• ; \i - r .n a., •7 rf f A Ir r { r �..
2.*"+' NUMBER OF BEDROOMS t..: i�-3 •.....*.'— . ,. 3 -� . , ,.. , ,rte _. , ,t', �. , . ;;�.
�7 i -"•.r rr, r.: . .fi r =
:., 4 4/i sT^Ji:>7Q V.vtMr/1•P14 F Y•: i1 �ilT r,bL ), 'j 1 Y r d,
y 3. '`„TYPE OF WATER SUPPLY - `f'4
'.L _:.r.,�n�{4:.e..t...cai1'l:asb.k•D4cw.,:af.:.:lv.td'.:31.r ,�._. J.. ~�:f ,t .r �!, t rJ:l. r<�! .y..
r 'L 'h W .mv,�,4h M'-•{'91rw •rn r.r•-xv-v.•r .1.`. - l .. wr ti r Ate:.
v
t ) Individual well Xxx
y n ,Community ell.%
Public water. ... _ _ .
--.•-- NOTE: If community well system, provide written confirmation from State ADEC attest- .'
_ Ing to the legality and status of system.
r R s t c
4 .a TYPE;OF WASTEWATER DISPOSAL
Individual on siteXXX a 1 4. '�, 3
7 ) g
Holding tank-•..�.,-w,•�••-m T., , �., :,. , t-, {v y..; r.� Y
Ya\ � �w 4
R• 1 • 1, i M J I1 7 yr e o• , h ` , tf� •�`
_ � i !...r m.r ,1 ! .z.: ♦ x.M,1.^!i ...r a' .. a i.2..'�., arlwsi .. ,... 1' ' , r..t1 .f 1„ • < , L
i • � Community on-site 117:'
? 1
rCla r pr t �". ,7 J1.1r` � r . i�'Ji v)•.\4 t .
Tpn:4 ,} '^' rlµ'J( MT r ♦wn ,{i >'JY`.•1'rC/ ¢C - r' )" _ g1ti)j [`!i3ti
Public sewers • 1 �
..r,L A f'• l l..l• 1 7r'.Ma 'S 4r. . i' _.1 �1 .,'
V
_ . y u. - - - N, 1111 1t
NOTE If community wastewatersystemr provide written, confirmet�on from State ADEC ,
attesting to the legality and status o/system 7 1 r
72-M (F4r.141) Fr MOA m
5. STATEMENT OF INSPECTION BY ENGINEER
i .
As certified by my seal affixed hereto and as of the validation date shown below, l verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms -.
and type of structure indicated herein. I further verify that based onthe Information obtained from _4
the Municipality of Ancnorage,files and from my investigation and inspection; the"on-site water
supply and/or wastewaterr disposal system is in compliance withlall Municipal and State codes,
ordinances; and,regulations in effect on the date of this inspection
Name ofFlrm- SISENGINEERiNG _ ` --•'Phone''G'�y-- 979 -
17034 Eagle River Loop Rood No. 404
`Address -
�Engineersslgnature,• _ Date
-Er" r. .+
OR
17
t, i gni l2= enwic vii
17.
r, ft ROBERT G COW.W F rVr
ti
.� l�
,
DHHS SIGNATURE ftta
-Approved bedrooms.
n. t rY t w T'>- 7 I 4. t� Ls k •` '� Rt 1. .' ty tva .v4 ♦ wt w +p.
Disappro 1.
e.i r ^il+t
'Conditional approval for bedrooms 'with, e,Wowmg stipulabons
i tT. ii-
-AT,i< 2rt fi'r '�.vT i �. .L•_ . e YYi i'.• �.. { 'si%
.i ...�u � v _.•f w.a+tin'.., ,.1,,.>.�a4-. T1. .. .. ..i :AY .1' .. �5�+��Y`" �{S_ `,;.
' S - V - 1 moi: rs•
.rwG1 iJ J.. ... 1.,..r f,..'�C..f i a..::4_.. ..'♦...... '...-..b. a. .. w._r...'J..ai....J..�-...:..L ..w_
a...,_,. -_.+rn .: a-.�... Giro- ..:Y w,':."•."i A ... :._... ., ._-r .. o,a ,. ... -� __.m.. xi va.•vruz#mrrh v....w..vw cvv.u. r>,•. !.:. �.
w
::Additional Comments :
��1t; f .yw V•• •l9 O ,Llf �'.:"!t a i+'21./3t w•'Y l.La •1f ...
`Sy"� ,@ se,c i? �r3TacDate"r//ve >�JS .q�
.�.t
CAUTION
:�he•Munici li r!chora e ti .- r, _
_ pe tyi w g Department of Health and Human Services' (DHHS) issues Health Authority
`kAjrproval•Ce 'baled only upon the representations given in paragraph 5 above by an independent
,, proteswoirialengin8erregisteredintheStateofAlaska.TheDHHSdoesthisasacourtesytopurchasersofhomes
<andthelrlendinginstituttonsinorcJertosatistycertainfederalandstaterequ(remenb EmployeesofDHHSdonot
_,conduct lns
pections or analyze data before a certificate is issued The Municipality of Anchorage is not '
_..-.. , ... ..
responsible for errors or omissions in the professional engineees work
t:n-WsOt.aW) e.m ►lwm
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825"L" Street, Room 502 0 Anchorage, Alaska 995010 (907) 343-4744
/0 `--
Health Authority Approval Checklist r'r 1
Legal Description: "7- It 1144c. 1) T,mlft a to x irl
A. WELL DATA
Well type r2 , VA 7C
Log present (Yo
NJ
n
Parcel I. D.: o / 51 - a -7
0
m
If A. B. or C, auach ADEC letter. ADEC water system number
Date completed v / q 7 0
Total depth S- a Cased to ti
Sanitary seal (91N) Y £ S
f P4R hoot f--•..(
FROM WELL LOG
Ire.
U/K
Static water level U /K
Well production
V /K
t Casing height (above ground)
u
1 �4--
Wires properly protected y/N) %E I
AT INSPECTION
)�1eI96
g.p.m. g.p.m.
d Aer 4 wF
WATER SAMPLE RESULTS:
Coliform 0 Nitrate 0.1 Other bacteria D
Date of sample: I to r/ 9 (.. Collected by: S & S ENGINEERING
17034 Eagle Rive Loop Road Yo. 204
B. SE IOLDING TANK DATA Eagle River, Alaska 99577
Date installed S—/)`° / 7O Tack sire I a ro Number of Compartments I Cieanouts®/N) Y E S
Foundation cleanout (Y6 "0 Depression (Y/l1 N o High water alarm (YAW /' O
Date of Pumping `>' // r pumper /tit
C. A13SORPTION FIELD DXTA
S/>0/70 I- 'CR)l3 L
Date installed 1 Y 7 6 Soil rating (g. p.d./ft' or f System type 7 c c N
av' z at' f r' 1
Length S's ' WigW 3 ' Gravel thickness below pipe y -r ' Total depth 10 '/s. '
6r* 4
Effective absorption area 4 +r Monitoring Tube present&M Yf JJ Depression over field (YAIS5 N e
Date of adequacy test 1 It /61 b Results(Fail) P,+ rS For 3 bedrooms
DRY a4 41`0 L ri, S,
Fluiddepth in absorptign field before test (in.): H '9" immediately after at 7 gal. water added (in. ): y
a"ri.�� 4 -71 j 4 s o f-4
Fluid depth Ae P's " (ins.) Minutes later: a 3 q Absorption rate = 'y CO t a.p.d.
Peroxide treatment (past 12 months) (Y/N) ^ r" K new J If yes, give date
D. LIFT STATION
Date installed Size in gallons
Manhole/Access (YM)"Pump on" leve "Pump off' Ic%cl at* _
High water alarm level at* *Datum
Cvcles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
holding talc on lot 9 S ; On adjacent lots /0 J 'r'
Absorption field on lot /00 t ; On adjacent lots loo / f
Public sewer main N /A Public sewer manhole%leanoul v � A
Sewer /septic service line
Litt station N 14
SEPARATION DISTANCES FROh SEPfI HOLDING TANK ON LOT TO:
i t
Building foundation Property line S Absorption field S /
Water main/service line Y 0 t Surtax wateddrainage /0 a t Wells on adjacent Tots � S
n
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Budding foundation 1't7 t"t" Water maudservice line W 0 +
Surface water 10 0 Driveway, p ddng/vehicle storage area *0 '
Ctutain drain Nen £ K ti OW ni Wells on adjacent lots go Property line J n ' -)c
-w- %✓ R °la.0070
F. ENGINEER'S CERTIFICATION
I certify that I have determined thru field inspections and review ofUunfcipal records
in conformance wtt V 0.4 HAA Ruf Ines to effect on this date.
Signature -����
Engineer's Name /etlB�R,— C_ l owd✓ .�
Date
HAA Fee S 0166' 4D c� Waiver Fee S _
Date of Payment Date of Payment
Receipt Number % J�L1 �� Receipt Number
Rev. 9195 OSS: haawk.doc
aotnnr C. COWAN
CE•8801
are