CINERAMA TERRACE BLK 2 LT 16
Ci'onerama Terrace Block 2 Lot 16 #020-581-03 Municipality of Anchorage L On -Site Water and Wastewater Section • (907) 343-7904 49AV0Zd ofi2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201231 I PID Number: 020-581-03 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑® New ❑ Upgrade Name Brian Gehring & Mara Ostroot ABSORPTION FIELD ❑ Deep Trench OR Wide Trench El Bed El Mound Site Address 16930 Kings Way ❑ Other Phone Number of Bedrooms Soil Rating i Total depth from original grade 2 2.0 GPD/SF 1.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 0.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Cinerama Terrace 2 16 Fill added above original grade 2.0 Ft. Gravel length 30 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station I Tank Line 150 Ft;! 1 n/a Ft. Well 100'+ 96.9 100'+ f n/a 25'+ TANK ❑ Septic 9 S.T.E.P. ❑ Holding ❑ Other Manufacturer Orenco Capacity 1500 Gal. Surface water 50'+ 50'+ I 50'+ n/a Material Number of compartments Lot Line 5'+ 10'+ 5'+ n/a NA Fiberglass 2 Foundation 10'+ 10'+ 10'+ n/a LIFT STATION Manufacturer Capacity Remarks Orenco 250 Gal. Alarm location House Electrical installed by Capstone PIPE MATERIAL House to tank 3034 Tank to drainfiefd 3034 Installer A+ Home Services Drainfield 3034 Co/MT 3034 inspector Pannone Engineering BENCH MARK (Assumed elevation) 1432 fl Inspectio im 7/10/20 7/13/20 Location and description 2nd 3`d 7/13/20 4`h 7/20/20 Bottom Trim @ point B ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional F Oco Approval: Date �P� _. * 4 TH 1 � �� • Pd Steven R. Pannone �� � '. CE 8149 A-1�` Septic System (�� Approved ►\�� Date Note: this approval does not include well permit requirements. (Nev ubwz/i 6) mn0` �=CO D CD { O ;J C C r x x m< FTI v� mFpcnG moo omzZo=D m* zoomo O -+N Dc pm0 Com pz (n m z 0 0 m NOTES: RECORD DRAWING (n r `2 -1 Z D60 SD M0O�Zmm0U)z G7 in N) N -. Fri \7 GO mrnD D r- m m m <n O Z (� c m 0) a, A NOTES: RECORD DRAWING -- oPC r Cf) -1 D60 SD M0O�Zmm0U)z D \ in N) N -. D \7 0) -P -P, W N 10 0) a, A N co N o -P \J 6) -P -P N 0 00 U o 10 p0 w (O N cy) Ut iz 0 -- oPC > Z\�- omFxZ- DQ D`2 f rN Cf) D x z0�J(nm X D60 SD M0O�Zmm0U)z D \ .. O m wo Do w OOnpoNpF) D p 0 (Jl -Tl m ZOpo oN wpm �--i >a 'Ozy-'�� 0om� om S70 a o m �7 -t V O x Cn p m 0 to m O \ 2• \ \ \ ` Or `OO e ry m ` D N m _ m N \ — \ Or > 7 m \ \ r I m i � \ I / \ Y44 Nix rF) Q Q \ m \\ \ bbbt \ PANNONE ENG SVGLLC (G.I. 'IOSS) REVISIONS uH c P.O. BOX 1807 PALM�ER, AK 99645 _'PSE. �F ACgS+++ REV t: to/27/20 scn�F 7/2020 PHONE (07) 745-8200 FAX (907) 745-8201 =�. �i94 CINERAMA TERRACE B2 L16 DRAWN SITE: 16930 KINGS WAY ACP ft— BRIAN GEHRING & MARA LEE OSTROOT .5`�a° R ce-a149 ,,� . as 3915 LOCARNO DRIVE _ SITE PLANa;ap, — ANCHORAGE, AK 99508 1" = 60' P.I.D. NO 020-581-03 PERMIT NO. OSP201231 2 OF 2 to n \ — — D \ -- \ om z0 \ \ \ m, mo 0 iz 0 \ \ — — — — --• \- X m (� D v -t m -i > r _ rcz �' D - O co nc P1 m 0-40 co mvDo M. --o \ o z e24t \Z \ O \ 2• \ \ \ ` Or `OO e ry m ` D N m _ m N \ — \ Or > 7 m \ \ r I m i � \ I / \ Y44 Nix rF) Q Q \ m \\ \ bbbt \ PANNONE ENG SVGLLC (G.I. 'IOSS) REVISIONS uH c P.O. BOX 1807 PALM�ER, AK 99645 _'PSE. �F ACgS+++ REV t: to/27/20 scn�F 7/2020 PHONE (07) 745-8200 FAX (907) 745-8201 =�. �i94 CINERAMA TERRACE B2 L16 DRAWN SITE: 16930 KINGS WAY ACP ft— BRIAN GEHRING & MARA LEE OSTROOT .5`�a° R ce-a149 ,,� . as 3915 LOCARNO DRIVE _ SITE PLANa;ap, — ANCHORAGE, AK 99508 1" = 60' P.I.D. NO 020-581-03 PERMIT NO. OSP201231 2 OF 2 V V 6_ V L L'-. \..1 6 Development —Services Department Buildin _q Safety Division On -Site Water & Wastewater Pro rar o ., i 4700 Eltnore k.oad c P.O. Box 196650 Anchorage, AK 99507 s „ ; e r Y Mark Begich tesuwv.muni.org7onsiie Mayor (907)343-7904 Well Log Permit Number: OSP161210 Date of issue: 10/14/16 Date Started:7/18/17 Date Completed: 7/18/ 17 Is well located at approved pennit location? (x I Yes U No Legal Description: Cinerama Terrace blk2 Lt16 G:3341 Property Owner Name & Address: Gehringg Brian M 169301(ings Way Dr. Anchorage, AK 99516 Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To stickup 0 2 overburden 2 4 sandy gravel 4 11 gravel w/ some sand 11 41 clay 41 77 water & gravel 77 83 Water Sample Results: Arsenic: N p ug/L Nitrates: ao 31 mg/L Total Coliform Bacteria: ep, colonies/100mL t r r n Method of Drilling IJ air rotary U cable tool Casing type: steel Wall Thickness: .250 inches Diameter: 6 inches Depth: 83 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 25 feet Pumping level: feet after hours pumping gpm Recovery Rate: 10 gpm Method of Testing: airlift Well Intake Opening Type: Rx Open End n Open Hole Screened Start feet Stopped feet R Perforations Start feet Stopped feet Grout Type: entonite Volume:gran.ujes Depth: 20' Start 0 feet Stopped 20 feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? F 5fl Yes M No Method of chlorin tablets Comments: Well Driller: Hefty Drilling, Inc. 3540 Akula Dr. Anchorage, AK 99516 Attention: The well driller shall provide a well log to DSD within 30 days of completion. uedeiopmenT .services ueparrtaenT Ame Building Safety ©ivision On -Site Water & Wastewater Program 4700 Elmore Road Jx P.O. Box 196650 Mark Begfich Anchorage, AK 99507 s E Mayor www.mun:i.org/ (907) 343-7904 Pump Installation Log Well Drifting Permit Nunn bear: 4;w" q Date of Issue: .Parcel Identification Number: Legal Description o 611 I L -t /� G f 2> Property Dw ner Name & Address: 16cll i3 r 7,o ij,jj� leii is Pump installation Date: -7— I c1 _ I? Pump Intake Depth Below Top of Well Casing: 7C), feet Pump Manufacturer's Name: f �� Pump Model: 1 Q i=� - - 1 6 J, Pump Size '/a hp Pitless Adapter Burial Depth: feet Pi#less Adapter Manufacturer's Name: Pitiess Adapter Installer: iv)�, Well Disinfected Upon Completion? F� Yes ❑ No Method of Disinfection : C'4 ar art T Ab� Comments: Pump Installer Name: j P.O. Toxcilz'30 Andwrage, AK9951.1 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. BUILDING DETAIL 1°=20' 7 4' so'_ SCEP GVH G\- \ p ro S p \ 1V 1 -STORY FRAME \ HOUSE W/ \ DAYLIGHT 8 , BASEMENT c 0' < 7S6, O lb* 6.1' \ LOT 16 161,173 sq. ft. o. Z \ OF~�� u?�S7 76 TRACT D �ilk�� 6,>' 3 LOT 15 LOT 17 5��ga 3612, � 5 66° Q GAS METER EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (83-547) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. 0 30' 60' IT- .'A- 9 LH T-'A-9TH r B SaIii, �o �i s '- LS -14837 J` = �Fn SJR - it OFESSI JOB # 2015; IL' I i 30' C.) m C7 I O r m II � 0 E�: I I Im Z n z m Cn m Irn C I I0 O (> m '` m m z - ------------- - O -�-.� - ___-__^_, UNNAMED STREAM I I o �••� � I I I :tl C S�EO m NOP 5 I I ELECTRIC SEPTIC - METER ( LE STANDPIPES._ I SEPTIC _..��P„ WELL UTILITY T PEDESTALS LE CLEANOUTSSEE BUILDING BUILDINGS° DETAIL 234.5 5��ga 3612, � 5 66° Q GAS METER EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (83-547) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. 0 30' 60' IT- .'A- 9 LH T-'A-9TH r B SaIii, �o �i s '- LS -14837 J` = �Fn SJR - it OFESSI JOB # 2015; MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://wwrlv.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP201231 Work Type: WellSeptic Renewal Tax Code Number: 02058103000 Site Legal Address: CINERAMA TERRACE BLK 2 LT 16 G:3341 Site Mailing Address: 16930 KING'S WAY DR, Anchorage Owner: GEHRING BRIAN M 50% & Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date �r l�cparrmcuC Lot Size. in Sq Ft: Total Bedrooms: 7/10/2020 7/10/2021 161173 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: Date: Date: 7 1 O Io'7 o 9 MUNMPAUTY OF ANCHORAGE Development Services Department Phone: 907-343-7 On-Site Water & Wastewater Section - Fax: 907-343-7 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 020-581-03 Property owner(s) Brian Gehring Day phone Mailing address 3915 Locarno Dr, Anchorage AK 99508 Site address 16930 King's Way Dr Legal description (Sub'd., Block & Lot) Cinerama Terrace B2 L16 Legal description (Township, Range & Section) Lot Size 161173 Sq. Ft. Number of Bedrooms 2 APPLICATION 1S FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial ❑ Single Family (SF) Q Septic Tank ElUpgrade ❑ (w/wo ADU) Holding Tank ❑ Renewal P Duplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well P Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. ignature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: 7 LS 7.0W Date of Payment: Receipt Number:___ 0� 8 28 (S _ _ Receipt Number: Permit No. OSPz012 3 1 Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201231, Rebecca Carroll, 07/10/20 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 14700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://tivww.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP171325 Work Type: WellSeptic Renewal Tax Code Number: 02058103000 Site Legal Address: CINERAMA TERRACE BLK 2 LT 16 G:3341 Site Mailing Address: 16930 KING'S WAY DR, Anchorage Owner: GEHRING BRIAN M 50% & Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date: u Delmrtinent Lot Size in Sq Ft: Total Bedrooms: 712/2019 7/1/2020 161173 Q Disposal Field © Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 2 i o Tv Cill A Lo bi-C S , - ? t� e. 1/a z� i Received By: Issued By:Q�f'�('iC'���x Date: `21 Date: '7 a t UNMPAUTY OF ANCHORAGE 1:4��ns Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERM/ELL PERMIT APPLICATION Parcel I.D. O a 0- 581 0 3 Property owner(s) Bri on Ge,hr► r a -k M- ora Lee Os+roofDay phone Mailing address .3115 I-oco-rno twlve AY, 9950$ Site address j 693 o Kivna's U)"1j j �rtve Legal description (Sub'd., Block & Lot) C 1 NE Z AO1 A 1 ERRii C F_ E>2 L A 6 Legal description (Township, Range & Section) Lot Size 1 '� 7 3 Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field © Initial © Single Family (SF) Septic Tank Upgrade El(w/wo ADU) Holding Tank ElRenewal Duplex (D) ❑ X, ❑ Multiple Dwellings ElPrivy (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (5lgn2ture of property owner or authorized agent) Permit/Rush Fees: _ 1`{ d Date of Payment: Receipt Number: 5 "7 $ Permit No. _� 5 3 a Permit App_9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services uc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com October 17', 2017 Subject: Expired On -Site Water and Wastewater Permit Permit Renewal Request Permit Number: OSP161210 Legal Description: Cinerama Terrace 132 L16 �V�,5? 8 9 Ip1 7 ti OCTT 7 20,1 ti n 0zp1.9c' This is a request to renew the permit for the above mentioned lot. All site conditions remain the same. The construction still will not affect the health, safety, or development of the surrounding lots. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer 02b 5? J 63 Mailing: P.O. Box 100217, Anchorage, Al( 99510-0217 Physical: 332 East Manor, Anchorage, Al( 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 x� eobt - \Nq 2\- -\- n - ` t '-� PANNONE ENG SVC LLC (C.I. 1088) PHONE (907)X745-8200ALFAX (907R, AK)745-8201 4` ��,•�.� � ni :.. $seven annoae CE 8149 p DATE FOR CONSTRUCTION645 ��c„nn-h0� x A � O N In SNC �O TtDZ prn W C O olln �4c N D �7DIn <0m-'X0_mD0_� r D V Z QJ \ D -.D.� Dr, nZTW r�TI rg -N (n LOCDr nT C_n o U nm-o-i(r1 rri � p Dm r� m��� m Z D �(n0m -"-9 D t m --{ D n W D z�-GE---I ,�tn��� o zm mx A < �Dcn o 1 A.TJ-1 m OO O� �='I .D.{IV� -_i.. .. z mmp �N co moo O m pOa� �(V� -Icn.. �Z.. z m'TO (n z r o O x O Z Z 0 2 D ZOn — DrTl 2 -' G) O m D Z O D y m o oc o O m� d "'i cy zo \� WO NN ON o. o _ y O cn WO OOn�N Off' o O. O nD Fl m op Z O O � r ---i OW � QW r�ri --i>;0 6— �C > zm z �� m r*ID Ti o m �m D�� I ley O �mm J�� D0 = U) �� =-o M m;u -_+ O Z am Z-0 p -tom.. Z p za�l,� O Ln --j a- n A R n N m � (J X n cn O X O (l7 Cdr om. c') V) m O -I r*i O U) iA £ nn m x x� eobt - \Nq 2\- -\- n - ` t '-� PANNONE ENG SVC LLC (C.I. 1088) PHONE (907)X745-8200ALFAX (907R, AK)745-8201 4` ��,•�.� � ni :.. $seven annoae CE 8149 p DATE FOR CONSTRUCTION645 CHANGE ORDER / - 91b1 � \ ( fTl r/7 W DOD ^ Z D o I Z Z me Zo Z c r D r- ❑rX SITE PLAN \ \ 1J \ ,ZdjN'A r T1> Z Y rri n Am -Z= 10 RN _ ,\ mo eoA- m-1 �d-� <-A OA y =moi I d "'i cy zo Z tTlZ'-" d M cn Fl 82 Q � \ Ocz\ r t m - i x z rrl\ N m \ n A R \ I � o v \ Cdr om. c') V) \ qD to o D iA £ nn x ? n \ o L N v m \ \ 3 o ` � �d NOTES: PANNONE ENG SVC LLC (C.I. 1088) PHONE (907)X745-8200ALFAX (907R, AK)745-8201 4` ��,•�.� � ni :.. $seven annoae CE 8149 REVISIONS DATE FOR CONSTRUCTION645 CHANGE ORDER SCALE0200522 t" = 60' CINERAMA TERRACE B2 L16 SITE: 16930 KINGS WAY BRIAN GEHRING & MARA LEE OSTROOT 3915 LOCARNO DRIVE ANCHORAGE, AK 99508 P.I.D. NO 020-581-03 DRAWN JRA SITE PLAN PERMIT N0. OSP171325 SHEET 1 of 1 Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com March 15, 2019 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. 0. Box 196650 Anchorage, Alaska 99519 Subject: Cinerama Terrace, Block 2, Lot 16 Drain Field Under Driveway Waiver Request Ladies and Gentlemen: I am writing to request a waiver to install a drainfield under a driveway per 15.65.2106.5 Exception. See sheet 3 of plan set for section and calculations. As designed the D3034 PVC pipe will deflect no more than 0.5% under a live highway load of 20,000 lbs well within the limit of 7.5%. With 4 - inches of rigid insulation the frost protection will be equivalent to 7' of cover. The monitor tubes on the fields will be located on either side of the driveway and will not be affected. Granting this waiver will not pose a threat to the safety of this lot or the surrounding lots. Please contact me if you have any comments or concerns. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer March 5, 2019 Attachments: -Site Plan AriCI-"0ri:g% iv'lailing. P.O, B -ox 1100217, .-'micilora e, AK C-495'-10-02'17 P :Inter Mailing: P.O. Box 1807, Palmer, AK 99645 Te;ephorle: (907) 745-8200 FAX: (9017) 745-8210:1. JM ag1w 1311ilding e.>setttitds for it better tomorrow - JANUARY 2009 FL EX iBLE PIPE THEORY I AB`�% . I F-\ i.__ h t. J { 1r 1. - . 3 PVC pipes are classified as flexible pipes. They flex without breaking when loaded externally from soil weight and vehicular traffic. Rigid pipes, such as those made of concrete or clay, do not perceptibly flex when loaded and experience wall crushing when their load limit is reached. This mode of failure for rigid pipes has given rise to the terms "crush strength" and "D -Load", but these terms do not apply to PVC pipes. When a PVC pipe encounters external loading, its diameter will begin to deflect, meaning its sides will move outward and slightly downward. If the pipe is bur- ied in supportive soil, the stiffness of the soil will resist the deflection (see Figure 1). This action and reaction is the key to how a PVC pipe carries external loads. Figure I FLEXIBLE PIPE DEFLECTION UNDEFLECTED DEFLECTED FLEXIBLE PIPE FLEXIBLE PIPE TOTAL LOAD: SOIL + LIVE O nSl 9 � r � # a k 0 -- + A, 'Z`L I U Ow Cmn 2 (r I AB`�% . I F-\ i.__ h t. J { 1r 1. - . 3 PVC pipes are classified as flexible pipes. They flex without breaking when loaded externally from soil weight and vehicular traffic. Rigid pipes, such as those made of concrete or clay, do not perceptibly flex when loaded and experience wall crushing when their load limit is reached. This mode of failure for rigid pipes has given rise to the terms "crush strength" and "D -Load", but these terms do not apply to PVC pipes. When a PVC pipe encounters external loading, its diameter will begin to deflect, meaning its sides will move outward and slightly downward. If the pipe is bur- ied in supportive soil, the stiffness of the soil will resist the deflection (see Figure 1). This action and reaction is the key to how a PVC pipe carries external loads. Figure I FLEXIBLE PIPE DEFLECTION UNDEFLECTED DEFLECTED FLEXIBLE PIPE FLEXIBLE PIPE TOTAL LOAD: SOIL + LIVE VERTICAL SOIL REACTION FORCES — OD+.: -,x — The combination of the embedment soil stiffness and the pipe stiffness form a system that acts to support external loads. By itself, the pipe may not support much weight, but the soil/pipe system can have tre- mendous load capacity. A PVC pipe's resistance to deflection in an unburied state is measured by its "pipe stiffness". Pipe stiffness is usually less significant than soil stiffness in PVC pipe installations, but in general, a higher pipe stiffness results in a higher load capacity. Soil stiffness is most affected by the level of compac- tion achieved, and to a lesser extent by the soil type. Soil stiffness values for various conditions and soil types have been derived through extensive testing. CALCUL ATI e& IG i"`iL:.OA YSr..iL E Ss -.+MAL. 'DEQ TH Because a PVC pipe flexes rather than breaks when loaded, the failure criterion is not fracture strength. Instead, a limit is placed on pipe diametric deflection. This limit is expressed in terms of percentage reduction in diameter due to external loading. Industry recommen- dations for maximum deflection are shown in Table 1. MAXIMUM RECOMMENDED DIAMETRIC DEFLECTION PVC Pressure Pipes 5% PVC Sewer / Drain Pipes 71h% PVC Electrical Conduits 5% A "failure" of a flexible pipe system from external load- ing is defined by the point at which the top of the pipe begins to experience inverse curvature. Research has shown this point occurs at a minimum of 30% deflec- tion; recommendations for maximum deflection there- fore incorporate safety factors of 4:1 or 6:1. Page 1 of 4 O nSl J W OU 0 0 -- + Q) CD U Ow Cmn 2 (r VERTICAL SOIL REACTION FORCES — OD+.: -,x — The combination of the embedment soil stiffness and the pipe stiffness form a system that acts to support external loads. By itself, the pipe may not support much weight, but the soil/pipe system can have tre- mendous load capacity. A PVC pipe's resistance to deflection in an unburied state is measured by its "pipe stiffness". Pipe stiffness is usually less significant than soil stiffness in PVC pipe installations, but in general, a higher pipe stiffness results in a higher load capacity. Soil stiffness is most affected by the level of compac- tion achieved, and to a lesser extent by the soil type. Soil stiffness values for various conditions and soil types have been derived through extensive testing. CALCUL ATI e& IG i"`iL:.OA YSr..iL E Ss -.+MAL. 'DEQ TH Because a PVC pipe flexes rather than breaks when loaded, the failure criterion is not fracture strength. Instead, a limit is placed on pipe diametric deflection. This limit is expressed in terms of percentage reduction in diameter due to external loading. Industry recommen- dations for maximum deflection are shown in Table 1. MAXIMUM RECOMMENDED DIAMETRIC DEFLECTION PVC Pressure Pipes 5% PVC Sewer / Drain Pipes 71h% PVC Electrical Conduits 5% A "failure" of a flexible pipe system from external load- ing is defined by the point at which the top of the pipe begins to experience inverse curvature. Research has shown this point occurs at a minimum of 30% deflec- tion; recommendations for maximum deflection there- fore incorporate safety factors of 4:1 or 6:1. Page 1 of 4 In order to determine the suitability of a particular burial Table S depth, a system designer estimates the pipe deflection, , through the use of an empirical equation called the "Modi- fied Iowa Equation". A simplified conservative version of the equation is presented below: MODIFIED IOWA EQUATION 1 0.69 0.76 0.83 0.87 0.90 2 1.39 1.53 1.67 1.74 1.81 0.1 (W' + P) 100 /o = pDEFLECTION 3 2.08 2.29 2.50 2.60 2.71 0.149 (PS) + 0.061 E' 4 2.78 3.05 3.33 3.47 3.61 Where: 5 3.47 3.82 4.17 4.34 4.51 6 4.17 4.58 5.00 5.21 5.42 % DEFLECTION = predicted percentage of diametric 7 4.86 5.35 5.83 6.08 6.32 deflection. s 5.56 6.11 6.67 6.94 7.22 W'= Live Load (lbs/in2): pressure transmitted to the pipe 9 6.25 6.88 7.50 7.81 8.13 10 6.94 7.64 8.33 8.68 9.03 from traffic on the ground surface. Live Load values are -11 7.64 8.40 9.17 9.55 9.93 found in Table 2. 12 8.33 9.17 10.00 10.42 10.83 P = Prism Load (lbs/in2): pressure acting on the pipe from 13 9.03 9.93 10.83 11.28 11.74 the weight of the soil column above the pipe (also called 14 9.72 10.69 11.67 12.15 12.6415' "Dead Load"), Prism Load values are found in Table 3. 10.42 11.46 12.50 13.02 13.54 is ' 11.11 12,22 13.33 13.89 14.44 PS = Pipe Stiffness (lbs/in2): a flexible pipe's resistance 17 11.81 12.99 14.17 14.76 15.35 to deflection in an unburied state. Pipe Stiffness values for 18 12.50 13.75 15.00 15.63 16.25 JM Eagle products are found in Table 4. 19 13.19 14.51 15.83 16.49 17.15 20 13.89 15.28 16.67 17.36 18.06 E' = Modulus of Soil Reaction (lbs/in2): stiffness of the 21 14.58 16.04 17.50 18.23 18.96 embedment soil. Values for Modulus of Soil Reaction are 22 15.28 16.81 18.33 19.10 19.86 found in Table 5. 23 15.97 17.57 19.17 19.97 20.76 24 - ` 16.67 18.33 20.00 20.83 21.67 25 2 6 17.36 18.06 19.10 1,,O .86 20.83 21.67 21.70 22.57 22.57 23.47 s r r„ 27 18.75 20.63 22.50 23.44 24.38 28 19.44 21.39 23.33 24.31 25.28 1 12.50 29 ,' 20.14 22.15 24.17 25.17 26.18 2 5.56 26.39 13.14 30 20.83 22.92 25.00 26.04 27.08 3 4.17 23.61 12.28 31 21.53 23.68 25.83 26.91 27.99 4 2.78 18.40 11.27 32 22.22 24.44 26.67 27.78 28.89 5 1.74 16.67 10.09 6 1.39 15.63 8.79 33 22.92 25.21 27.50 28.65 29.79 7 1.22 12.15 7.85 34 23.61 25.97 28.33 29.51 30.69 8 0.69 11.11 6.93 35 24.31 26.74 29.17 30.38 31.60 10 7.64 6.09 36 25.00 27.50 30.00 31.25 32.50 12 5.56 4.76 37 25.69 28.26 31.67 32.12 33.40 14 4.17 3.06 38 26.39 29.03 32.50 32.99 34.31 16 3.47 2.29 39 ' 27.08 29.79 33.33 33.85 35.21 18 2.78 1.91 40 27.78 30.56 34.17 34.72 36.11 20 2.08 1.53 41 28.47 31.32 35.00 35.59 37.01 22 1.91 1.14 24 1.74 1.05 42 29.17 32.08 35.83 36.46 37.92 26 1.39 43 29.86 32.85 36.67 37.33 38.82 28 1.04 44 30.56 33.61 37.50 38.19 39.72 30 0.69 45 31.25 34.38 38.33 39.06 40.63 35 46 31.94 35.14 39.17 39.93 41.53 40 47 32.64 35.90 40.00 40.80 42.43 Simulates 20 ton truck traffic - impact. ` 48 33.33 36.67 41.67 41.67 43.33 Simulates KOM !b/ft railway load - impact. 180.000 ibs. due! tandem gear assembly; 26 -inch spacing between tires and 66 -inch center -to- - 49 34.03 37.43 42.53 42.53 44.24 center spacing between tore anti aft tires under a rigid pavement 12 inches thick - impact. tveglig b!e live toad inUuence. 50 34.72 38.19 43.40 43.40 45.14 Page 2 of 4 Tab le SOIL SOIL TYPE Slight < 85% Proctor Moderate 85% - 95% Proctor High > 95% Proctor, CLASSLoose (Unified Classification System)'. w a; 0 <40.Q relauve denstty 40,0 ,0.o . relaiwe density > 70;0 relative density Class V Fine-grained Soils (LL>50)b Soils ;with medium to high plasticity No data available; consult a competent soils CH, MH, CH -MH engineer; Otherwise use E' = C Class IV Fine-grained Soils (LL < 50)Soils with medium to no plasticity CL, MLML-CL, with less (hen 25% coarse-grained particles 50 200 400 1,000 Fine-grained Soils (LL < 50)Soils with medium to no plasticity CL, ML,ML-CL, Class III with more than 25°o coarse-grained particles 1004001,0002.000 Coarse- 100 400 1.000 2,000 grained Soils with Fines GM, GC, SM, SCC contains more than 1201. fines Coarse-grained Soils with Little or No Fines GkA1, GP, Sw, SPC Class 11 contains less than 12% tines 200 1.000 2,000 3,000 Class I Crushed Rock 1,000 3.000 3,000 3,000 Accuracy in Terms of Percentage Deflection --2 ±2 ; a.0.5 "ASTM Designation D 2487. USSR Designation E-3 'Ll_ = Liquid limit '= Or any borderline soil beginning with one of these symbols (i.e. GM -GC, GC -SC) For _ 1&; accuracy and predicted deflection of 3"u. actual deflection v,oUld be bet:veeh 2`T, and =55. Note: Values applicable only for fitly less than 50ft (15rn). Table does not include any safety factor. For use in predicting milial deflections only: appropriate DeOection Lag Factor must be applied for long- term deflections. It bedding faIs on the borderline between tv+o compaction categories, select lo:aer E' value or average tt•.e trio values. Percentage Proctor based on taboratory maximum dry density from :est standards using abcut 12,500 h4b,cu it (598.000 J/rn) (ASTM D 898, AASI ITO T-99, USSR Designation E-1 1). 1 psi = 6.9ktdhn'. Source: -Soil Reaction for Bured Flexible Pipe" by Amster K Howard. U.S. Bureau of Reclamation, Denver Colorado. Reprinted with permission hem American Society of Civil Engineers Journal of Geo- technical Engineering Division, Januar; 1977, pp. 33-43. A pipe system designer uses this equation to predict PVC pipe deflection given type of PVC pipe, burial depth, soil density, type of traffic, type of embedments oil, and compaction density of embedment soil. The designer then compares the predicted deflection to there commended maximum deflection in Table 1 to check if the burial depth is appropriate. -. Shallow Burial A pipe system designer is interested in using ASTM D3034 SDR 35 PVC sewer pipe in a shallow -burial installation with the following characteristics: -1 foot burial depth: - 120 pounds per cubic foot soil density - H2O highway traffic - sand embedment material - 90% Proctor density embedment soil compaction % DEFLECTION = 0.1 (P+W1) 100 0.149 (PS) + 0.061 E1 % DEFLECTION = 0.1 (0.83 + 12.5) 100 0.149 (46) + 0.061(2,000) % DEFLECTION = 1.0 ±1 % The maximum predicted deflection is 2.0%, well below the maximum recommended for PVC sewer pipe in Table 1 of 71/2%. Minimum Burial Depth: The minimum recommend- ed burial depth for PVC pipes beneath a highway is one foot. This recommendation assumes proper specifi- cation of embedment materials and compaction, and proper installation. Deep Burial A pipe system designer is interested in using ASTM D3034 SDR 35 PVC sewer pipe in a deep -burial instal- lation with the following characteristics: - 45 foot burial depth - 120 pounds per cubic foot soil density - H2O highway traffic (Note: Live loads are negligible for deep burials) - sand embedment material - 90% Proctor density embedment soil compaction % DEFLECTION = 0.1 (P+W') 100 0.149 (PS) + 0.061 E' % DEFLECTION = 0.1 (37.5 + 0) 100 0.149 (46) + 0.061(2,000) % DEFLECTION = 1.0 ±1 % The maximum predicted deflection is 3.9%, well below the maximum recommended for PVC sewer pipe in Table 1 of 71/2%. For more information, see the following JM Eagle Technical Bulletins: - PVC Pipe Trench Construction - Deflection Testing of PVC Sewer Pipe - PVC Sewer and Drain Pipe Burial Depth Charts - PVC Water Pipe Burial Depth Charts Page 3of4 T 2bsp 4 165 25 129 235 18 364 1 %2 600 2 300 3 300 4 200 6 120 EB -20 20 EB -35 35 DB -60 60 DB -100 100 DB -120 120 Y2 5,928 3/ 3,136 1 2,547 1 % 1,397 1 Y2 1,008 2 596 2 '/2 784 3 509 4 307 6 154 8 104 10 78 12 64 %2 17,066 3/ 9,078 1 6,995 1 1/4 3,930 1 Y2 2,911 2 1,846 2 %2 2,141 3 1,473 4 949 6 607 8 417 10 356 12 330 Page 4 of 4 Carroll, Rebecca M. From: Panilo, Mark M. Sent: Wednesday, June 5, 2019 11:50 AM To: Carroll, Rebecca M. Cc: Barganier, Tony A. Subject: Re: R16-1938 Follow Up Flag: Follow up Flag Status: Flagged Becca, H2O is a little light even for the engines, which are some of.the lightest apparatus. Another problem is the weight distribution. H2O doesn't put enough weight on the back axle group. E80 is overkill, but it works. More than likely, the tenders (the heaviest apparatus) will not be driving down the driveway anyways, but they can as it works. Mark M. Panilo Fire Inspector - Fire Prevention Anchorage Fire Department Office: (907) 267-4975 Cell: (907) 444-1199 panilommCc@muni.org On Jun 5, 2019, at 1:08 PM, Carroll, Rebecca M. <rebecca.carroll(@anchorageal<.gov> wrote: Mark, Here is a scan of the septic design site plan that shows the driveway (including what I believe is their proposed fire turn -around). I also included the section drawing and the pipe deflection calculation guide in case either of those are of interest. They are currently assuming Highway H2O live load. I'm not sure this is adequate for a fire truck, but the Railway E80 looks like it might be excessive. I did do the calculation assuming the Railway E80 live load and it still results in a pipe deflection less than 7.5%. Becca Carroll Onsite Water and Wastewater Municipality of Anchorage 343-7908 From: Barganier, Tony A. Sent: Wednesday, June 5, 2019 10:04 AM To: Panilo, Mark M. <mark.paniloPanchorageal<.gov> Cc: Carroll, Rebecca M. <rebecca.carroll@anchorageal<.gov> Subject: R16-1938 Mark, Please come and talk to me and Becca regarding the driveway for permit R16-1938. It is on my desk. 1 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this J Day of of 20 E0 , by and between ' .� - rf •xrerein the `'OWNER.." and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenantscontained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as AJ ug o+e-x located at (legal description) 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) VV Throughout the term of this Agreement, the Owner shall enter into a service agreement f with an AVXFWTS service and maintenance provider approved b}- the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (,-,, nvi g/2018) PAQP 1 rf I Owner acknowledges that the Municipality may request records of maintenanCe and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. _a Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing `guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. 'Perm. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the richt of the Municipality thereafter to enforce every provision hereof 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any Provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. _ . Page 2 of 3 OWNER: By: (signature) Date: 51131W W (print name) STATE OF ALASKA ) ) Ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument \Vas acknowledged before me this �'/5�,\day of , by PU I ALASKA C:M:] My Commission expires: 02-1-ly4/-7olzJ: MUNICIPALITY: By:(signature) elzv-r d Z (print name) Date:4,51Q70O Title: On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161210 Tax Code Number: 02058103000 Work Type: WellSeptic Initial Permit Effective Dates: October 14, 2016 to October 14, 2017 Design Engineer: Pannone Subdivision: CINERAMA TERRACE Site Legal Address: CINERAMA TERRACE BLK 2 LT 16 G:3341 Owner/Address: GEHRING BRIAN M 50% & OSTROOT MARA LEE 50% 3915 LOCARNO DRIVE ANCHORAGE AK 995085023 Site Mailing Address: 16930 KING'S WAY DR, Anchorage Lot Size in Sq Ft: 161173 Total Bedrooms: 2 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By: Is13 OM-)t%oo MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-79 g u) 11 Development Services Division Fax: 907-343 On -Site Water & Wastewater Program u ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-581-03 Property owner(s) Brian Gehring & Mara Lee Ostroot Mailing address 3915 Locarno Drive, Anchorage AK 99508 Site address NHN Kings Way Drive Day phone Legal description (Sub'd., Block& Lot) CINERAMA TERRACE 132.1-16 Legal description (Township, Range & Section) Lot Size 161,173 Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: Date of Payment: (N all that apply) Receipt Number: _ �O� Receipt Number: Absorption Field Initial ❑X Single Family (SF) ❑X (w/wo ADU) Septic Tank Upgrade ElDuplex (D) ElHolding Tank F1Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: q Waiver Fees: Date of Payment: Date"of Payment: Receipt Number: _ �O� Receipt Number: 1heN P/Permit No. Lv Waiver No. Permit App_::- : : Lac Pannone EngineerrintSaMces uc Steven R. Pannone, Principal Registered, Professional Engineer E-mail: steve(@Panenaak.com 2 September 2016 Subject: CINERAMA TERRACE B2 L16 Septic System Install Permit Request - - Design Narrative This is a design narrative to request a re -issuance of a permit to install an initial septic system and well for this property. We are changing the system from a 4 BR conventional system to a 2 BR conventional due to the change of building concept by the owner. The updated system is located within the area to Test Hale 2 originally submitted and all other design factors remain the same. Currently the lot is undeveloped. This lot and the surrounding lots are served by private wells. There are no wells within 100' of this system. 1. Soils. Two test holes were performed on this lot by PES in September of 2003, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 6.7' below the surface in the test hole 2 monitor tube after the 7 -day monitoring period. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of 0.45 gallons/day/square feet was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. - a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The topography of the property slopes from the east to the west. The ground around the proposed system slopes from the east to the west at approximately 5%-10%. — The proposed installation will not affect the future development of the surrounding or existing lots. There are no-wetfs within 100 feet of the proposed septic location. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 D INAG16 D 0 — � r / DRAINAG / M/ UE NOR SCA �.1 = 5 ' z 1 - J � /� / ERT 100' SURFACE 'I N H2O SETBACK N N � to OD 100/ IJ / // -WELL P (Oil O 100' URFAC I Cr H SETB K RESERVE FIELD BASED ON ADVANTEX (NIC) / 138.1 ) O INSTALL ABSORPTION FIELD. P I (3 EA)45.OLFx5.0'Ws0.5'E.D., 1.0'TD. 1 J 1.25"0 LINES W/ 0.125" HOLES 30"O.C. / 2BR W/ 1.3' SAND FILTER & MT AT BOTH �P) / ENDS. / r / 1 1 MAINTAIN 10' SEPARATION FROM 17.3 / WATER LINE TO ABSORPTION / FIELD AND TANK 7.8 1 / V A 1 INSTALL 1250 TANK (P) W/ FC, DCO & FS AFTER SEPTIC 100' SURFACE \ 1 \ I /�.� 50 1 H2O SETBACK ` \ 1 ` SD 1 SD I/ SDS �!! �/ / WELL E f 171 I i ( i �r NOTES: PANNONE ENG SVC, LLC Date FOR CONSTRUCTION. P.O. BOX 102954 ANCHORAGE, AK 99510 09/06/16 �••' PHONE (907) 272-8218 FAX (907) 272-8211Scale *.. •.• * 1.. — 60' ..... .. .. ... P.I.D. NO CINERAMA TERRACE B2 L16 020-581-03 seven R: anno ie DRAWN JRL BRIAN GEHRING & MARA LEE OSTROOT 8149 PERMIT NO. 3915 LOCARNO DRIVE OSP 161210 SITE PLAN ANCHORAGE, AK 99508 i`L/� J• Sheet ql. 1 OF 2 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: INSTALL NEW 1250g SEPTIC TANK, AND SOIL ABSORPTION SYSTEM. INSTALL WELL 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 6.7 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF ANAPPARENTWATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 6.7 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. - 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: - I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE - ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: TITLE.: DATE: DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 2(300 gpd) - - TANK SIZE: 1250g STEP PERC RATE: 40 MPI SOIL RATING: 0.45 GPD/SF - ABBREVIATIONS AREA ROD: 667 SF TH TEST HOLE SYS. TYPE: WIDE TRENCH 0.5'ED _w —w — WATER LINE / (p) PROPOSED MIN LENGTH: 134 LF WELL RADIUS (E) EXISTING USE: —ss —ss — NEW SEPTIC CO CLEAN OUT NO. (3EA)45.OLFx5.0'WxO.5'- E.D., 1.0' TO _ MT MONITOR TUBE NO. - W/ 1.3' SAND LAYER TYR TYPICAL TOTAL AREA: 675 SF - R&R REMOVE & REPLACE NOTES:Date PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 09/06/16 FOR CONSTRUCTION PHONE (907) 272-8218 FAX (907) 272-8211 * * .... ... ... .. ... Scale NTS P.I.D. NO CINERAMA TERRACE B2 L16... 020-581-03 BRIAN GEHRING & MARA LEE OSTROOT 3915 LOCARNO DRIVEOSPI61210 3ev°n 814"OR° DRAWN JRL PERMIT No. Sheet SITE PLAN ANCHORAGE, AK 99508 "Tf`' 2 OF pas.pas.read_only, 6/9/2008 00:00:00 "rM [at_ tklw RopkrkN MaRarw[• R«rt• Co. wn0oR uU••• � � w � � � •�,,, 1wR w a� PlW"i07.E-31155 CRNA 02MI0300001, CINERAMA TERRACE, Block Z, Lot 16, 169701 WAY Dii MRtR• vMTII Il w,aWre,e 9w[k• vW R CRF --!r jnow AwWirbn' . caRt�stl I . 9Jn,ltt•1• I' p«en:nr. ,' w•,N... TNiaeI l: ASeI-0lOU001 i RRon••k•n err Oi4Y2W) y FkRACE t LatBpax �s , .. C w `:WMI: wild t••*' 2a,Y� 1011 a. P WAV EW - bqv E � pM•: It tik4 - r tbv,q• ewRN.E f Pbc f Rlti• Wr« rRroK f Ptic - (� P,kra f Can�veY . Reba: I.. fComme,wlfAernin Rapo••e ti•r R-3 nESUEtltulFA V f'R«Iee:RW TYN a/wmk: �.c^ y�� ••`a •,� wake•«,pk 2NR Mp, iW Rv,1,wHe. B90«RO•rpe _ RweYke: o ••RkkV iIE ACIryE{1111511UM•Itl I - cco:j—iw co:m—uaam iaN—c- ,a _ 9o•tin•Rl:r—,Asttb•um. r�wou000 a !, [Nk•e:❑ v.Rr r«ro 0uroAiER,rpry A.. . . P.,". Aeu•iaq G✓q•9m W,.kM . 7 f i4� lhul(AC4A6 MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water Q Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW070071 Date Issued: May 22, 2007 Expiration Date: May 21, 2008 Parcel ID: 020-581-03 Legal Description: CINERAMA TERRACE BLOCK 2 LOT 16 Design Engineer: 0062 PANNONE ENGINEERING SERVI( Site Address: NHN KINGS WAY DRIVE Owner Name: ERIC SUOJA Lot Size: 161173 SO. FT. Owner Address: 3913 TOM WHITE CIRCLE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99504 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By: Date: fyhtFt�t Date: 05a1 19 Issued By: Date: S l 7 Municipality of Anchorage • Development Services Department Building Safety Division On -Site / Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. opb - _67 /- 03 Property owner(s) Mr. Eric Suoia Day phone 350.7296 Mailing address3913 Tom White Circle, Anchorage, AK Zip Code 99504 Site address NHN Kings Way Drive Zip Code 99516 Legal description (Sub'd., Block & Lot) Lot 16, Block 2 Cinerama Terrace Legal description (Township, Range & Section) Lot Size 161.173 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms 4 THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Pannone Engineering Services, LLC (Signature of property owner or authorized agent) Date of Payment: Date of Payment: Receipt Number: 41/C786 Receipt Number: (Rev. 11/05) Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (907) 272-8218 (907) 272-8211 Fax May Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot 16, Block 2 Cinerama Terrace Well & Septic System Permit Request Response to Review Comments Ladies and Gentlemen: I am writing in response to your review comments dated March 12, 2007 concerning the above referenced permit request. I will respond to your comments in the same order that you presented them. Comment: Does the following comments need to be on permit application?: "For MoA review, not to be used for construction" Response: Yes. This comment will remain on the drawings until your review is complete and I receive written notice that you have completed your review and that you have no more comments. At that time I will issue the drawings to you with the indication that they have been "Issued for Construction". Comment: Groundwater monitored for 3 years: Are there any groundwater readings from your testholes 1&2 in the spring time? Response: I have performed ground water monitoring through May 13, 2007. The highest ground water reading occurred on April 13, 2007 with the water depth at 6.7 feet below ground level. The water reading as on May 13, 2007 was at 7.4 feet below ground level. I have added this information to the soils report and detail sheet. The building, driveway and well location has changed due to comments from the MoA Zoning Department. I have modified the site plans to show these new locations. Once final review comments are received and written notification that your review is complete, I will issue "For Construction" drawings to be attached to the permit. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Civil Engineer Attachments: Pannone Engineering Services, LLC Consulting Engineers March 5, 2007 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot 16, Block 2 Cinerama Terrace Well & Septic System Permit Request Ladies and Gentlemen:. P.O. Box 102954 ge, Alaska, 99510 )071272-8211 Fax I am writing to request that a permit to construct a new well and septic system be issued for this property. The proposed systems will serve a proposed four-bedroom house. Currently the lot is undeveloped. The lot will be served by a private water supply. The surrounding developed lots are served by private water systems and septic systems. The private wells are located over 100 feet from the proposed soil absorption system. I. Soils. Two test holes were excavated. See the attached soils logs. Ground water was monitored for three years. Ground water was encountered in Test hole one at a depth of 12 feet below ground level and stabilized at a depth of eight and a half feet (8.5') after the monitoring period. Historical data indicates that the ground water tends to rise to within five feet (5') of the surface during the spring high water period for this area. The proposed system shall be installed at a total depth of one foot (1') to take into account the known presence of high ground water in this area. See the attached section on sheet 3 of 6. Bedrock was not encountered in the test holes. It is my opinion, based on the results of the percolation tests and overall soils appearance of the soils; an application rate of 2 gallons/day/square feet should be used, using a Class III advanced treatment system (Advantex). 2. Soil Absorption System Design. a. Percolation Rate: b. Application Rate: c. Design Flow: d. Min. Absorption Area: e. Total Depth: f. Effective Depth: g. Width: h. Reduction Factor: i. Minimum Length: j. Design Length: k. Effective Absorption Area: 1. Septic Tank Size: 30-60 Min Per Inch 2 600 gallons per day 300 sf 5 feet 0.5 feet 5 feet 0.0 60 feet 60 feet 300 sf 1,250 gallon STEP W/AX 20 Pod & Pump Vault 3. Surface Water: There is surface water on the lot. The proposed septic tank, treatment system and drain field will maintain at least 100 feet from all surface water and drainage ditches. Page 2 of 2 4. Topography: The average topography in the area of the proposed septic system is approximately seven to eight percent (7% to 8%) based on the survey plot plan. The proposed installation will be greater than 50 feet uphill from the shoulder of the steep slopes. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: C:\Work\Letters\16-2 Cinerama Terrace.001.doc 141 A EXI. w -15 THIS PROJECT kxlsr"G DRAINgCE 10 !4 160' CREEK—",--, OFFSET kPROPOSED ADD Its PRbPQS 1 Y ? SEPTIC ,SYSTEM YSTEM S 2 9 % 04 EXISTG QISTIG 2 1 1, 1 % CREEK ! WELL I EXIST'G S�PTICI AREA 17' / ( / '- z7 /A ISSUED FOR CONSTRUCTION 7— PANNONE ENG SVC, LLC REVISED Date P.O. BOX 102954 ANCHORAGE, AK 99510 03-05-07 (907) 272-8218 FAX (907) 272-8211 5 TMPHONE 1*-cale 100' Lot 16 Block 2 Cinerama Terrace P.I.D. NO • Steven Pon a Eric Suoja —20-581-03 PERMIT NO. CE 8149 3913 Tom White Cir. Anchorae, AK 99504 g SITE SW07xxxx Sheet (907) 350-7296 PLAN EXISTG SEPTIC AREA 15 ; 'I, NO WELLS OR SEPTIC W11N 100 FT. EXIS F'G DRAINAGE PROPOSED 15008 SEPTIC TANK If / PROPOSED W. ADVANTEX f., WELL AX20 S POD CREEK& AUX. PUMP VAULT 00 SET AK 2 10 14 r PROPOSED AY 4BR ✓11? .145.$L- ;4 HOUSE q, ss4 TA IN 10' BET 7. WATPP�INE & SEDT 11 ss wiv vRESERVE FIELD 2 TRENCHES 30LFx5'WxO.5'ED INSTALL ULA TE LINE PRIMARY FIELP--- FOUNDATION 'LINDER DRIVEWAY 2 TRENCV,5- CLEAN-OUT JOLFx5;60.5 'ED SEE StCTION A _A EXIST'G SEPTIC AREA ISSUED FOR CONSTRUCTION 5-19-07 OF A(. \kl ....... Aw .. ..... Steven R. .,e CE 8149 okk"O'5-19-07.- ....... PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 REMSED Dote 03-05-07 Scoie 1".60, Lot 16 Mock 2 Cineramo. Terrace Eric Suoja 3913 Tom White Cir. Anchorage, AK 99504 (907) 350-7296 -1 P.I.D. NO 20-581-03 DESIGN 'GN fSh PLAN PERMIT NO. W07mxmx L2 S W 't 2 of 6 e of 6 3 a --p.5}-- W _J it Lr LL ISSUED FOR CONSTRUCTION 5-19-07 REVISED Dote OF A( PANNONE ENG SVC, LLC �•"•' •g1�Sflll P.O. BOX 102954 ANCHORAGE, AK 99510 03-05-07 # 9 ykl� PHONE (907) 272-8218 FAX (907) 272-8211 Scale � Lot 16 Block 2 Cinerama Terrace P.I.D. NO Steven P • none j Eric SUo,ja 20-581-03 I1 4. CE 8149 .�w 3913 Tort White Cir. swo xxxx 11 s 0�-t9-oz_ Anchorage, AK 99504 rr1, DESIGN Sneel \ " C907> 350-7296 DETAILS 3ot6 3en1 11011NON �$ ONV OO GN •���/Q•J. � .oN r V fNU C O •�I. ,aV.".� VI r V C � 1n d l K , 'F r•�N Y ae ooeY- 38511 tlOLNON '1.j.. W N OW O = N 1 ep 0 i LO- P p0 6 F rL r7 Ln U $ W U \t z. a �_ bN J a. 310H.... 3 N c o 310HN 0 r,J � �3 � y jx N opz f Nf 1n0 N.310 8✓�F{ N g NO N.313 N011.ONno1 u 1•I 3 I NN W _J it Lr LL ISSUED FOR CONSTRUCTION 5-19-07 REVISED Dote OF A( PANNONE ENG SVC, LLC �•"•' •g1�Sflll P.O. BOX 102954 ANCHORAGE, AK 99510 03-05-07 # 9 ykl� PHONE (907) 272-8218 FAX (907) 272-8211 Scale � Lot 16 Block 2 Cinerama Terrace P.I.D. NO Steven P • none j Eric SUo,ja 20-581-03 I1 4. CE 8149 .�w 3913 Tort White Cir. swo xxxx 11 s 0�-t9-oz_ Anchorage, AK 99504 rr1, DESIGN Sneel \ " C907> 350-7296 DETAILS 3ot6 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: 4—BEDROOM HOUSE. NEW DRAIN FIELD AND NEW ADVANTEX TREATMENT SYSTEM W/ AUXIL. PUMP VAULT. 4. GROUNDWATER IS EXPECTED TO BE ENCOUNTERED DURING EXCAVATION. AS EVIDENCED BY THE SOIL TEST HOLE INFORMATION. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 5 FEET BELOW EXISTING GRADE. NOTIFY THE ENGINEER IMMEDIATELY. 5. DISTRIBUTION PIPING SHALL BE 1 1/4'0 PVC WITH 1/8-0 ORIFACE SPACED ® 30" O.C. 6' JIM SLIDE SECTION OVER THIS SHEER EXTEND TO BRIDGE EXCAVATION DESIGN CALCULATIONS Number of Bedrooms - 4 Total Bedrooms -4 Design flow - 150 gal/br/day, Total flow - 6009/day TANK SIZE: 1500g Steel Advantex tank ADVANTEX AX20 P00 24• INSULATED Advantex Tank Detail SOIL ABSORPTION SIZEI Advantex Sewer Treatment System Class III System - Perc Rate= 30-60 min/inch Application Rate= 2 GPD/SF Min Area: 600gpm/2gpd/sf = 300 sf Design Field 5 -Wide Trench, 0.5' ED, 60 LF Design Area: 601fx5'W=300 SF AUXILIARY PUM BASII PASSIVE AIR ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN—OUT T(/ TANK CLEAN—OUT NO. C(/ CLEAN—OUT NO. M# MONITOR TUBE NO. LEGEND WATER LINE/ —W—V— WELL RADIUS —ss—ss— EXIST'G SEPTIC —ss—ss— NEW SEPTIC 0 - CHAINLINK FENCE — — DRAINAGE/CREEK ISSUED FOR CONSTRUCTION 5-19-07 � -'QOF= (�h PANNONE ENGINEERING SVC, LLC REVISED o31-os-o� ��Pc� • ? f1�, P.O. BOX 102954 ANCHORAGE, AK 99510 � _ I .yt+�/ PHONE (907) 272-8218 FAX (907) 272-8211 Scale NTS •••• •• • Lot 10 Block 2 Cinerama Terrace P.I.D. NO 20-581-03 Steven 0he CER914091� � 3913ETom Whiric te Cir, PERMIT NO. ( Anchorage, AK 99504 xx DESIGN sheet 1�0`_= (907) 350-7296 NOTES a Or B 3 I b �' � nv\ SOILS LOG - PERCOLATION TEST iq`P�OFA(gs��1f PANNONE ENGINEERING SERVICES j*: TM ,tl� P.O. BOX 102954 ANCHORAGE, AK 99510 Steven 'norie (907) 272-8218 Il (�l-5-14-07-mo i PERFORMED FOR: Eric Suoja DATE PERFORMED: 09-29-03 LEGAL DESCRIPTION: Lot 16 Block 2 Cinerama Terrace S/D TEST HOLE 1 SITE PLAN 1 ` SLOPE 11 Brown silts �15� 1 ML W/ Organics I i r ; _ 5 IrI" 6 j I I I i i Gray Silty Gravelly Send I I r VD, Moist, 8 SM Cobblers and H LST E I I (I IH1,i .�.. Boulders, I I i +� r' 9 Gloclel Till 1 10 TH2 12 13 SLOPE WAS GROUND WATER la ENCOUNTERED? No IS IF YES, AT WHAT BOH DEPTH? - N/A- TEST HOLE 16 DFPTH TO WATER AFTER 17 MONITORING? -10 18 DATE 10-11-03 2/20/07 -8 6' 19 5/13/07 -3.5' WATER Note: water accumulated READING DATE CLOCK NET TIME LEVEL NET DROP 20 in sink hole that Is still TINE READING Frozen. 1 09-29-07 PRESOAK PERCOLATION RATE 60(min/inch) PERC HOLE DIAMETER bin TEST RUN BETWEEN 3FT TO 4FT E COMMENTS: Test hole excavated by Dan Beek. Test Hole was presoaked before pert test. M1 d r PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. a U - - - 12.07 —2 37— 0 17� 7+ � 123 6 lig 07 30 I/2 6 10 - 6 - 137 0 SOILS LOG - PERCOLATION TEST PANNONE ENGINEERING SERVICES P.O. BOX 102954 ANCHORAGE, AK 99510 (907) 272-8218 PERFORMED FOR: Eric Suoja DATE PERFORMED: 09-29-03 LEGAL DESCRIPTION: Lot 16 Block 2 Cinerano Terrace S/D l 2 3 4 5 6 7 8 9 IO 1I 12 13 14 15 16 17 18 19 20 TEST HOLE 2 Brown silts W/ Organics Gray Silty Gravelly Sand VD, Moist, Cobblers and Boulders, Glociel Till SLOPE $T H LE WAS GROUND WATER ENCOUNTERED?Yes TF YES, AT WHAT DEPTH? -12' DEPTH TO WATER AFTER MnNITORING? -10' DATE, 10-11-03 ?/20/07 -9.5' 4/13/07 -6.7' 5/13/07 -7.4' .1�« TEST HOLE READING DATE CLOCK TIME NET TIME A LEVEL READING NET DROP 1 09-29-07 PRESOAK - 1214 6 1/8 3 1244 0 4 1244 6 P14 30 1/4 3/4 6 114 6 44 30 5 1/4 3/4 PERCOLATION RATE 40(nin/inch) PERC HOLE DIAMETER bin TEST RUN BETWEEN 3FT TO 4FT COMMENTS: Test hole excavated by Dan Beek. Test Hole was presoaked before perc test.