HomeMy WebLinkAboutMATHIESON LT 3AMathi'seson Lot 3A #051-102-63 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161288 Tax Code Number: 05110263000 Work Type: Septic Upgrade Permit Effective Dates: September 30, 2016 to September 30, 2017 Design Engineer: PANNONE ENGINEERING SERVICES Subdivision: MATHIESON Site Legal Address: MATHIESON LT 3A G:1359 Owner/Address: LEWIS DEBORAH L 6500 E 16TH AVE ANCHORAGE AK 995040000 Site Mailing Address: 20757 OBERG RD, Chugiak Lot Size in Sq Ft: 42427 Total Bedrooms: 3 This permit is for the construction of: N Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By: ;�Py6 0//'4°! /201& {a Se L9 2 a i 6 MUNICIPALITY OF ANCHORAG Community Development Department Development Services Division QD On -Site Water & Wastewater Program_ Phone: 907=343-7904 Fax: 907-343-7497 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-102-63 BUSH Property owner(s) Deborah Lewis Mailing address 6500 E. 16th Avenue, Anchorage, AK 99504 Day phone Permit/Rush Fees: 344 Site address 20757 Oberg Road .4 Date of Payment: `� j3 iso Date of Payment: Legal description (Sub'd., Block & Lot) Mathieson, Lot 3A Receipt Number: Legal description (Township, Range & Section) Permit No. O5P14?1 b Waiver No. Lot Size 42,427 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (0 all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank Q Upgrade nX Duplex (D) El Holding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes, property owner or authorized agent) A — Permit/Rush Fees: 344 Waiver Fees: .4 Date of Payment: `� j3 iso Date of Payment: Receipt Number: O9a2gE Receipt Number: Permit No. O5P14?1 b Waiver No. Permit App_" > Pannone Engineering Services uc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@oanengak.com September 29, 2016 Subject: Mathieson, Lot 3A Tank Replace Permit Request Desigp Narrating This is a design narrative for a permit to install an upgrade 1,OOOg septic tank to be issued for this property. The existing 1,OOOg tank is collapsing. It will be decommissioned per code and replaced. Currently the lot is developed. The proposed system will utilize a replacement 1,OOOg septic tank that will be connected to the existing drain field. The existing tank was installed 97' from the well and a waiver was issued (OSP131329). The new tank will be installed 100' from the well. 1. Upgrade Tank Design. A double clean out will be installed after the tank, and a foundation clean out installed before The tank will be located: 5'+ from any property line or building foundation 10'+ from any water line 100'+ from any surface water 100'+ from any private well 200'+ from any public wells The proposed installation will not affect the future development of the surrounding or existing lots. There are no surrounding wells within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 907.272.8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ' ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 2644720 ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME u� A • Q P NE Eyy UPGRADE MAIONGAODRESS I LEGAL ESCRIPTION LOCyIIOrJ O / � � L/ lN/Well NO. OF BEDROOMS U Y DISTANCE TO: / Absorptwor'a Dwe mg yr PEgp 1_1 N6 � S 2 Manufacturet�' ' �,� C d LLsIJb Ma e;a1A No. of bom artments to Lip, ca acity in gallons IF HOMEMADE: Inside length Width I Liquid depth d Y J02 DISTANCE T0: Well Dwelling PERMIT NO. S 2 H Manufacturer Material Liquid capacity in gallons O W= DISTANCE TO: Well ��/ Foundation / n Nearest Iq� liA a Off/-f-.'4�.� PEHM H 2 W No. of line Length %rip line P o Total len f fines Trencl.Tth J �C inches Distance .en lines H O Top of the to finish grade Material beneath the ! inches Totalphon area W V Length Width Depth PERMIT NO. <t- W� Type of crib Crib diameter Crib depth Total eflecbva absorption area DISTANCE TO: Well Building foundation Nearest lot line J J Class Depth Driller Distance to lot line PERMIT NO. W DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MA RIALS SOIL TEST RATING INSTALLER / ,q'1'CS REMARK ,5iA7V ' 7d) - DATE LEGAL K" V;P43 (Rev. 3/)8) - / r•11-1 r -a I r_: I P r _ I -r fl F= F=1 r-4 C= H 1_1 y I j E - 51-19 •.,_ DEPARTMENT OF HEALTH AND ENVIROWENTAL PROTECTION Ilii • 125 'L' STREET. ANCHORAGE, AK. 93_01 9.zt) 264-4r72fl 11rJ— ITE Er-JEF PFEE F<:M I T RER.t1IT rJO. C 790204 )# -�.2i APPLICANT MADELYNN PIATHLESON BOX 511 E. R. 68^ 235: LOCATION GLENN/OBERG RD. LEGAL L 3A MATHKISON SLB LOT SIZE 40030 SOURRE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH rtA}:IP1UM NUMBER OF BEDROOMS 3 SOIL EATING (SC! FT/BR)= 125 THE FEOUIPED SIZE OF THE SOIL ABSORPTION SYSTEM IS: C•CF='TH— 7.- LEr4 Ci -F"= 4 s:3F=:F-9%.- EL C•E PTH= THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OP. DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE E}.CAVATION CIN FEET). THERE IS 110 SET WIDTH FOP. TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION CIN FEET). *E EPT I C TFir-JK S~ I E-- 4_� � GF iLLC►I1�5 PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFOF,•r•1 THIS DEPARTMENT DURING THE INS-TALLATION IN'=PECTIONS OF ANY WELLS ADJACENT TO THIS PP.OPERTY AND THE NUt•1EER OF RESIDENCES THAT THE WELL WILL SERVE. --- -y-WID t_ � 7 I rAS F=,EI:--T I Or -J=• HF?E F= 1_I I F='ELN --- BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETNEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATF•`LJELL: OF: 1_.0 TO 200 FEET FROM Ei PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PEFs:r1 I Z' E: :P I F2E- C•EC Er•1E:EF= =71s 1' : '_-+ I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOP. ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IPJ ACCORDANCE WITH THE CODES I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REtU1P.E ENLARGEMENT IF THE RESIDENCE IS V-10DELED TO INCLUDE r10RE THAN 3 BEDROOMS. S I GNED : '--------- APPL -; "JT MADELYNN MATHLESON ISSUE .�. - -- - --- ----- - �------DATEv -lb�f7 --- V- 2 - 0 Ft E GEOT�CHNI CAL Et DEVELOPMENT CO. what -'depth d aril L. Oyster n t_ • dOX 90, Davis St., Eagle River, Alaska 99577 Installation: Seepages Pit Drain'Field 694.2774 of 6M-2280 RusseAOyster --. ._..... _. - .•: ..... :.. EedElfis' . 634-2774 SOIL- LOG -- .-- ___.. _ emz?80 Soils Er Foundations 'Land Development Performed for: Name: r;.:; I va 1iTel No. 6 Mailing Address: r' o. ivl ail =:1+1R Riv+ Ai,r:%�= 9v977 Legal Description: -1 Ve♦'4t95C^ .i+IlYil`ri9i nn '�O Depth (feet) Soil Characteristics 1 silt t.c ,r] ;.it.77 a roots ara organics. „_ j 27 ft.�Er by: Date_: 6y"l 25. 3 ;'d - Savri_v Gray._ .ath cobbles to 12 inches. Clan a-.! _10.3e:" 1CG sq. ft:%o% 6 t 7 8 �_:.; - 3riv�1]y :.irl, very clown ani wail grade -i. at 9 r 4 p ,• 10 ll: - 15 !6 q .. / ..' } x. airyly C.:i el with acbbles to 12 inrhe... '-all rrcunt. of- silts. 1iZ Q At iotLom of pit. of ....................... Ground Water Encountered: Yes No tc If yes, what -'depth d aril L. Oyster Proposed Installation: Seepages Pit Drain'Field rt�r,A�oPROFESS��y�.�'�"? CC.^snents: T1,' ` t K'foat'in �� a-a.a. +.:1 s;din '6f'taliN_ � 6 Performed by: Date_: 6y"l 25. r- a,J- gwtJ Municipality of Anchorage° On -Site Water and Wastewater Program < (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-102-63 Expiration Date: 1. GENERAL INFORMATION Complete legal description MATHIESON LOT 3A Location (site address) 20757 OBERG ROAD, CHUG IAK, AK 99567 Current Property owner(s) RICHARD & NORMA MATHIESON Day phone Mailing address 1914 LAKE SHORE BLVD., JACKSONVILLE, FL 32210 Real Estate Agent Day phone 2. TYPE OF DWELLING: [)j Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 1 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual [X] Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Received by: + Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ {�j0 Waiver Fee $ Date of Payment OtI o h a C Date of Payment Receipt Number tSa 5 Receipt Number COSH# C&C 1�1�i30 Waiver# iiSi�J1&91 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm AHC; I LHRH CONSULTING; INC The operational life of all well and septic systems are subject to these various; septic system. Therefore, ArcTerra can not give any estimate of how long a sl guarantee that no unseen encroachments, deficiencies or discrepancies exist. 6. DSD SIGNATURE __L System #1 Approved for. bedrooms System #2 Approved for, bedrooms. Disapproved. Phone 868-3791 Date 9n✓12 hA regnlatioos. The asaaamentof thecandmouof the well and septic ' due tosubsurface comtitiow thA mavnnt hr i.l.m IA A.::.: 1- Conditional approval for bedrooms, with the following M, 13' Original Certificate Date: p — Th Munid a"y n.horage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory 3e_ Other COSA blue sheet 9-i-12.dee Municipality of Anchorage Development Services Department Building Safety Division < On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: MATHIESON LOT 3A Parcel ID: 051-102-63 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID # Date completed unk Sanitary seal (YM) Y Total depth unk ft. Cased to *40+ ft. FROM WELL LOG Date of test — Static water level ft. Well production Well Log (YM) N Wires properly protected (YIN) Y Casing height (above ground) 18 in. AT INSPECTION 8/29/12 155 ft. WATER SAMPLE RESULTS: Coliform NEG colonies/100mL Nitrate 1.57 mg/L Arsenic: ND mg/I Date of sample: 8/31/12 Collected by: ArcTerra B. SEPTICIHOLDING TANK DATA Tank Type/Material Septic/Fiberglass Date installed 61979 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (YM) *Y Depression over tank (Y/N) N High water alarm (YM) N Date of pumping Pumper Jk C. ABSORPTION. FIELD DATA Date installed 616/79 Soil rating (g.p.d./ft2 or ftz/bdrm) 125 System type Deep Trench Length 25 ft. Width 3 ft. Gravel below pipe 8 ft. Total depth 11.7 ft. (Measured 8/29112) Eff. absorption area 375 fl? Monitoring tube Y Date of adequacy test 8/29/12 Depression over field N Results (Pass/Fail) Pass For 1 bedrooms Fluid depth in absorption field before test 56.4 in. Water added 600 gal. New depth 87.6 in. Elapsed Time: 1380 min. Final fluid depth 58.8 in. Absorption rate >= 150+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date -- D. LIFTSTATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at _in. "Pump off' level at _in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 96'+/- On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 251+ Holding tank 1001+ Animal containment areas 5n'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 51+ Property line 51+ Absorption field 51+ Water main 101+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots loo'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 30'+ Water main Water Service line 101+ Surface water 100'+ Driveway, parking/vehicle storage 101+ Curtain drain 50'+ (None Known) Wells on adjacent lots 1001+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in {fi conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KENNETH M. DUEFUS ?1i Date 9/7/12 COSA Fee $490.00 Waiver Fee $ Date of Payment Date of Payment Receipt Number Receipt Number (Rev. 11105) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage. ak. us (907)343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # 121430 During a recent COSA on-site inspection and test of the potable water supply well on Block , Lot 3A of Mathieson subdivision, the well's productivity was determined to be 0.83 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 0.1 - bedroom residence is 1 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. —x OBERG } WELL 0 U Q N�53, 00 9-7•2g (r) 97 ROADD-�+ JEHOVAHIREH STREET I ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: MATHIESON SUBDIVISION LOT 3A PLAT 78-50 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. 12-022 16. 2012 JLS I NW1359 I 1201 R -50l ,2hnb 09 � lR �S � g (H) = HELD (C) = CALCULATED (M) =MEASURED OO = FND RED.AR = END ALUMINUM MONUMENT ���� OF...... .4 'S01 49TH ......... .. .. OHN L. �.N �SCHULLERr o : LS -10408 z \- fessiono\ o PDL NDRp�.f' Tn � 1831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax N00°0215311E 139.47'(M) N00°00'00"E 140.00'(R) 10' UTILITY EASEMENT x � � x X I w LOT 3A �I w x G W } � x J M 00 SEPTIC r� � VENTS CJ ^ la—I x (' 2.01 • ^� x _ I 30.8' LLI o M pa Kdi x GP O 70 vMlI Op a � W x n C) Q O 066.4' O 0> l yr Q wm w O 0 I �� 322, O cel Z}�'P o ��� 40.5' o CD ass• .,� O ryQ W x OBERG } WELL 0 U Q N�53, 00 9-7•2g (r) 97 ROADD-�+ JEHOVAHIREH STREET I ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: MATHIESON SUBDIVISION LOT 3A PLAT 78-50 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. 12-022 16. 2012 JLS I NW1359 I 1201 R -50l ,2hnb 09 � lR �S � g (H) = HELD (C) = CALCULATED (M) =MEASURED OO = FND RED.AR = END ALUMINUM MONUMENT ���� OF...... .4 'S01 49TH ......... .. .. OHN L. �.N �SCHULLERr o : LS -10408 z \- fessiono\ o PDL NDRp�.f' Tn � 1831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax ARCTIC PUMP & WELL INC. Jun Sullivan _ PO Box 770197 nm wn srsi ) Eagle River, AK 99577 sons a e'iarKi (907) 688-2510 (907) 258-2510 (907) 745-2510 atw-7i:eci llo Pump Installation Log Well Drilling Permit Number: SW Parcel Identification Number: Date of Issue: Arctic Pump & Well, Inc. Page 1 of I Legal Description:Mathieson Lot:3A Property Owner Name & Address: Richard Mathieson Block: 20757 Oberg Rd �'hn oiak AK 90577 Pump Installation Date: 09-15-12 Pump Intake Depth Below Top of Well Casing: Feet Pump Manufacturer's Name: Dempster Pump Model: Pump Size: hp Pitless Adapter Burial Depth: feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: U/K Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Casing 40'+ with no perforations Pump Installer Name: Arctic Pump & Well, Inc, Arctic Pump & Well, Inc. Page 1 of I c>+oRgG ANCHORAGE WELL & PUMP SERVICE, INC. 330 E. 76TH AVENUE ��--- ANCHORAGE, ALASKA 99518 PHONE (907) 243-0740 FAX (907) 243-0742 FEDERAL I.D. 92-0153194 No GREAT LANG REALITY -KATHY GEP,ACI 11411 OLD GLENN HVOY EAGLE RIVER, AK 99577 invoice* 20121554 Awp Via: GREAT LAND REALITY NANCY STAHLY 20757 CIBERG RD PETERS CREEK Irfvoicz �RCTERRR re s`o ARC 1m lrHRAa Y € ? CONSULTING, INC z 212 E. 51" Ave, Anchorage, AK. 99503 m,�� Office (907) 868-3791, Fax (907) 868-3793 September 7, 2012 Jeff Poet, On -Site Engineering Technician Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: MATHIESON LOT 3A – WELL - SEPTIC TANK WAIVER Dear Jeff, Per your request, we are submitting a waiver request for the separation distance between the septic tank to the well located on the referenced lot. Per the John Schuller, LS as - built survey dated August 16, 2012—the septic tank first compartment cleanout was measured at 97'+/- to the subject property's well. Additionally, the 1979 Municipality of Anchorage (MOA) inspection report record documents show that the MOA approved the lesser separation distance. This well is located up gradient from the septic field. The well and septic are located on opposite sides of the house and have been in operation for over 30 years. Water quality results are acceptable. We are therefore requesting that a waiver to 95' feet between the referenced well and septic tank be granted at this time. We respectfully request that the waiver and the Certificate of On -Site Systems Approval be granted. If you have any questions or require additional information, please contact me at 868-3791 / FAX 868-3793. Respectfully, Arc Terra Consulting, Inc. Il/ Kenneth M. Duffus, P.E. Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907)343-7904 • Fax (907) 343-7997 http://Www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program pzenr .S' O C rye' Q . � epartm.ent **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP121329 PID#:051-102-63 COSA#:OSC121430 Permit#: Legal Description: Mathieson, Lot 3A Engineer: ArcTerra Applicant: Richard & Norma Mathieson Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 95.0 feet. This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. .................................................................... 0.......... Waiver is Granted: X Waiver is not Granted: Date: CIL5 / aZ Approved by: Name of Reviewer ..................... ................ ......................................... Rec#: N/A Amount: Waived Date Paid: N/A **** VARIANCE/WAIVER REVIEW ****