Loading...
HomeMy WebLinkAboutGRECIAN HILLS BLK 1 LT 1Onsite File Aff Mir f �� MOA has confirmed that the 2016 onsite systeml On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161077 Tax Code Number: 01707429000 Work Type: Septic Renewal Permit Effective Dates: April 28, 2016 to April 28, 2017 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: GRECIAN HILLS Site Legal Address: GRECIAN HILLS BLK 1 LT 1 G:2940 Owner/Address: COVINGTON CHARLES ALBERT 7761 MCLURE CIRCLE ANCHORAGE AK 995076232 Site Mailing Address: 8161 COX DR, Anchorage This permit is for the construction of: Lot Size in Sq Ft: 18473 Total Bedrooms: 4 Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By MUNICIPALITY OF Community Development Department Development Services Division 6 On -Site Water & Wastewater Program ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-074-29 Property owner(s) Charles Covington Day phone Mailing address 7761 Mclure Circle, Anchorage, AK 99507 Site address 8161 Cox Drive, Anchorage Legal description (Sub'd., Block & Lot) GRECIAN HILLS B1 L1 Legal description (Township, Range & Section) Lot Size 18,473 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑x Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal R Multiple Dwellings ❑ _ Privy ❑ (SF and/or D) Private Well ❑ _ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. authorized agent) Permit/Rush Fees: Ho Date of Payment: —1 Wit" Receipt Number: Oy01�4 61 Permit No. OSP 110101-1 Permit App_'_ ::L.:c: Waiver Fees: Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services LLC Steven R. Pannone, Principal g y 7 0 Registered Professional Engineer - (.rAIP',R 77 4)E -mail: steve(@panengak.com 2 0 2016 Subject: Expired On -Site Water and Wastewater Permit`° << 01 Permit Renewal Request 6 Permit Number: OSP131290 Legal Description: GRECIAN HILLS B1 L1 April 21, 2016 This is a request to renew the permit for the above mentioned lot. All site conditions remain the same and the construction still will not affect the health, safety, or development of the surrounding lots. Sincerely, Steven R. Pannone, P.E: Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 &%-& SpuMand Engoimearkg Environmental Consulting and Design _a SEPTIC SYSTEM DESIGN Grecian Ifills SID Block 1 Lot 1 Municipality of Anchorage July 9, 2009 Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 Subject: Well & Septic Permit Revisions 8161 Cox Drive Ladies and Gentlemen: We are revising the permit application for the proposed septic system at the above referenced property. Since the original application the wells on lots 2 & 3 block 2 Grecian Hills have been installed. Their zone of influence extends into our original septic system location. In order to maintain 100 feet of separation from these wells the reserve site is now the proposed location. The proposed system has been changed from an IDSF system to and Advantex system. Both the original site and reserve site will be around test hole #1. System: 1500 gallon Advantex tank with AX20 pod and a 15' by 20' bed. Soils: Two test holes were excavated on June 18, 2007. See the attached soil logs. Ground water was monitored for through June 27'", 2007. Ground water was not observed. Surface Water: There are no surface waters within 100 feet of either the proposed septic system arca or the reserve site. Topography: The average topography in the area of the septic system slopes to the south at approximately 10 %. Waivers: A waiverofthe 150 foot separation distance between aseptic system and a Class "C" well has been applied for from the Alaska Department of Environmental Conservation. 203 West 15'k Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net 001(910' -'+ -1- SpaMand Conga aewoonp Environmental Consulting and Design The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. I f you have any questions or concerns, please contact me at 279-3916. Sincerely, Lars Spurkland, P.E. Civil Engineer 203 West 15"Avenue Suite 203, Anchorage, AIC 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, LspurklandQQ gei.net 1 I t I I LOT 6 L III LO1 I I T5 ® '— I I III / I 1 III I E ® -t) (11 LOT 9 OT 10 ECORDS OE A KU WERE. MW FOR LOT f0. 1 14,\ COX RJvr I I LOT Qinr I C LOT I lyi LOT 2 I RI00,0', I � I I MOM, THIS IS NOT A SLAW WD W. WELL & SEPTIC LOCAM6 TAaN fM OM -SITE WATER AND WASTE WAIF DEPARTMENT DOMMENTAMY. ALL LOCAIMMS SHOW ARC APPROXWAIL LOT I LOT 1 i I 49th �• �.............st.. ."5.. jI 50 0 50 ix 150 Pal 250 300 -'■••••-- SCALP+ 1' = 100 Ft REV/S£D JULY 9, 2009 SPURKLAND ENGINEERING GRECIAN HILLS BLOCK 1 LOT 1 SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE ANCH. AX 99501 ADAM ALSORN DAM JULY 30, 2007 907 279-3916 8161 COX DRIVE SHEET • 1/3 GRID: 2630 PERMIT f OS Lb! 77 PIB k XXXXXXX GRECIANHILLSBIL1walM 1 ' I LOT 10 I I � I I I P �,► 1 ' G ' Q I I INSTALL 1500 CAL ADVANTEX TANK v W/ AX20 POD AND 13' X 20' OrD I LENGTH 20 fEET PIDIN 15 MT I TOTAL DEM 1.0 ffET ROCK DEPTH .5 fEET INSNLAAON 2 INCHES I _ 1 LOT 2 I I I Proposed hell-� wLOT I , R100.0' C*" - ' _ i RI .0' rAlXW Dow>ANK COOL I I REODIRL7IfN y tiI •5 .' I— a Assume base ova .+L° -r'14-a ® 140 el 111 a2l-A VIC -� -- T s I i ¢ Well �I1P 111 ��a�aaap,+ ' LOT 3 i ' i ` `� PSE �.„ '••.• I I • 49th • • ............ . LOT 2 `..(. R t^ A I I y a .� _: I i LOT 1 •0• : No. CE- iogou �C i5 D 25 7s , ,SU •.• .�, �. SCAL + -4 50 SON ISM , REV/S£D JULY 9, 2009 "IRKLAND ENGINEERING GRECIAN HILLS BLOCK 1 LOT I SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DATE. JULY 30, 1007 ANCH. AK. 99501 ADAM ALBORN 907 279-3916 6161 COX DRIVE SHEET: 2/3 GRID. 2940 PERMIT #QS 1(p107? PID # GRECIANHILLSBILIUV6 6' P �0121R01 SLIDE SEC Of 6' OVER THIS CONNEC TO PRC SHEER PROTECTI EXTENI BRIDGE IXCAVA. 11 I SPURKLAND ENGINEERING I I GRECIAN NILLS BLOCK I LOT I I I SEPTIC SYSTEM DESIGN I 8161 COX DRIVE DATE,IULY 9, 2009 203 W15th Ave Anchorage Ak 99501 SHEET: 3/1 GR1Di 2710 PERMIT / Q8P1G/0)LI PARCEL 10 / GrecianH111s8fLfD4revdwg RISTALL ORE! LFT STATION T25- DG 1 OR SCN 40 cr150' 5.0' a/16- HOLU AT 24- ON CENTER MONnoe nw 20.0' WTALL MON= TUBE CONSTRLCT TO' LONG BY 15' NVE SOL ABSORPTION BLD W/ Q5' ETTECDVE DEPTH SEWER ROCK #MALL MONITOR TUBE 2 FEET COVER (MRL) RTSTALL 2-AKH MULAIIOH RISTALL JLTER i'ABR/C 15,0' RISTALL ORENCO 1500 GALLON ADVANTEA' TANK AL1 Ono AX 20 1REATMENT UNIT ETTECW WASHED SEWER ROCK 1 125- DK SCH-40 PVC W/ J/16- 110L£S ?4. ON CENTER Xrvu arvutrvtcKtrvu I I GRECIAN HILLS BI Ll I I SEPTIC SYSTEM DESIGN ANCHORAGE, 20303 O W. 115th AVERAGE, AK 995Q2 8161 COX DRIVE DATE+ JULY 9, 2009 279-3916 SHEET, 4/4 GRIDt 2630 PERMIT j 11S)Plb%d-?-? PARCEL ID / GRECIANN/LLSB1L1D5REV.M Municipality of Anchorage Development Services Department Building Safely Division OnSde Water and Wastewater Program 4700 South Sragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Www a anchorage ek.us t9M 343-7904 Soils Log - Percolation Test Periom,ed For. Am h6rn Date Perk Legal Description: _ Gtt,EC1 AtV q iil5 RIM Lr 1 Township, Range, Section: 1 P D( 0 r I hard n WAS GROUND WATER A/0 , 9- 0 ENCOUNTERED4 NO o B 1D- IFYES,A7WHATDEPTHT —' L GODpMbw~AMr r 11- aro„ aonngT E 12- Da,.:' L 0.4 13- 1 1 ..... , p' LARS E SFU9KLA ell i Reading Date Gross Tane Net Tme Depth to Water Net Drop ('L1910-+ 1.05 O nl,. 3 q 8 Ole I1 1:35 , , 30 ,�, , 8 I(y it V4 „ to 2.O5 foo ; $ 3 N ZIA I 2:35 0 2' PERCOLATION RATE (5, 3 0W**m4a) PERC HOLE O"ETER W COMMENTS R'.. L ` TEST RUN BETWEEN ��FT AND FT &1Md {y� PERFORMED BY: _-Af5 SPVAA11A() I CERTIFY THAT THIS TEST W SS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINILt IN EFFECT ON THIS DATE. DATE: fp 2 0 nsPI G/03qL s Perfomred For. Legal Description: -NAL r;;70 1 1 Municipality of Anchorage Development Services Department Building Safety Division O"Ite Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519 -USO www cI.anchoraae.sk.us (907) 343-7904 Alam Soils Log - Percolation Test _A am Alborn Date Perk Garcim Wis 131K 1 41- Township, Range, Section: lltt A \W15Dme Gr���� WAS GROUND WATER ENCOUNTERED? a IFYE5,ATWHATDEPTH? L BA.N DpN to Wsr.r Am. P r Monaonng? E Darr b 2l 0 CC.' �s 9'1 ....S E.S.....PURKL. LAR11 SJo `V� Reading Date Gross Tine Net Tine Depth to Water Net Drop 1:11 rn O enrtn 111 15/140 143 is 1,.q70m 30 15 !/8 3f " !q 3/ 14 2:r3 GO ;n 15, 31,101 IIS NIP= i0,,1;� it It PERCOLATION RATE 'IV (Mft"~) r PERC HOLE DIAMETER kD PM '� I� 1` TEST RUN BETWEEN a FT AND 3 FT COMMENTS P(',, So�t"�t?cl PERFORMED BY: bm ufh�O,�—+ ttfR�Qr1� I 1rAIM CERTIFY THAT THIS TESTW S PERFORMED IN ACCORDANCE AND MUNICIPAL GUIDELI ES IN EFFECT ON THIS DATE. DATE: Gr Zl 0 0sPl (oID-13t,;z On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131290 Tax Code Number: 01707429000 Work Type: Septic Permit Effective Dates: August 29, 2013 to August 29, 2014 Design Engineer: SPURKLAND ENGINEERING Subdivision: GRECIAN HILLS Site Legal Address: GRECIAN HILLS BLK 1 LT 1 G:2940 Owner/Address: COVINGTON CHARLES ALBERT 7761 MCLURE CIRCLE ANCHORAGE AK 995076232 Site Mailing Address: 8161 COX DR, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 18473 Total Bedrooms: 4 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By, MUNICIPALITY OF ANCHORAGE njapi Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERNVELL PERMIT APPLICATION Parcel I.D. 017-074-29 Property owner(s) Charles Covington Day phone 223-2779 Mailing address Site address 8161 Cox Dr., Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Grecian Hills Block 1 Lot 1 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field El Initial ❑ Single Family (SF) 0 (w/wo AD U) Septic Tank El Upgrade ElDuplex (D) ❑ Holding Tank ❑ Renewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: NONE Distance: I certify that the above information is correct. I further certify that this is in accordance with Permit/Rush Fees: */e36 Date of Payment: g/,a3//5 Receipt Number: o:' sy98�!C? Permit No. Permd App_9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. mea spwmand Engomsflimg Environmental Consulting and Design SEPTIC SYSTEM DESIGN Grecian Hills S/D Block 1 Lot 1 Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 Elmore Rd Anchorage, Alaska 99519 Subject: Ladies and Gentlemen: Well & Septic Permit 8161 Cox Drive August 20, 2013 I am writing to request a renewal of permit for the construction of a new septic system and well for this property. The original permit was issued in October of 2009 and expired 12 -months later. A site visit was conducted on August 15`h, 2013. No changes have been made to the above referenced property and there does not appear to have been any changes in the development of the neighboring properties. If you have any questions or concerns, please contact me at 279-3916. Sincerely, L parkland, P.E. Civil Engineer 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Oct 07, 2009 Expiration Date: Oct 07, 2010 Permit Number: SW090205 Parcel ID: 017-074-29 Legal Description: GRECIAN HILLS BLOCK 1 LOT 1 Design Engineer: 0007 SPURKLAND ENGINEERING Site Address: 8161 COX DRIVE Owner Name: JACK ANDERSON Lot Size: 18473 SQ. FT. Owner Address: 10120 SALIX CIRCLE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99507 - This permit is for the construction of: Q Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: —� Issued By: Date: 6 Date: 1,0171,2 e Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907) 343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 611 -024"o"I Property owner(s) I _Day phone Mailing address Ib 120 �y 6V R _Zip Code g9S03 Site address gib 0 ZiD Code Legal description (Sub'd, Block & Lot) Grec)an Alb 13)KI t11 I Legal description (Township, Section & Range) Lot Sizeg, L%3 Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of pr6perty owner or authorized agent) Permit/Rush Fees: quo Waiver Fees: Date of Payment: ' Date of Payment: Receipt Number. �0� Receipt Number: (Rev. 11105) Environmental Consulting and Design _a SEPTIC SYSTEM DESIGN Grecian IIills S/D Block 1 Lot 1 Municipality of Anchorage July 9, 2009 Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 Subject: Well & Septic Permit Revisions 8161 Cox Drive Ladies and Gentlemen: We are revising the permit application for the proposed septic system at the above referenced property. Since the original application the wells on lots 2 & 3 block 2 Grecian Hills have been installed. Their zone of influence extends into our original septic system location. In order to maintain 100 feet of separation from these wells the reserve site is now the proposed location. The proposed system has been changed from an 1 DSF system to and Advantex system. Both the original site and reserve site will be around test hole #1. System: 1500 gallon Advantex tank with AX20 pod and a 15' by 20' bed. Soils: Two test holes were excavated on June 18, 2007. See the attached soil logs. Ground water was monitored for through June 27", 2007. Ground water was not observed. Surface Nater: There are no surface waters within 100 feet of either the proposed septic system arca or the reserve site. Topography: The average topography in the area of the septic system slopes to the south at approximately 10 %. Waivers: A waiver of the 150 foot separation distance between a septic system and a Class "C" well has been applied for from the Alaska Department of Environmental Conservation. 203 West 151h Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net Spars ORd Enaonewong Environmental Consulting and Design The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. 1 f you have any questions or concerns, please contact me at 279-3916. Sincerely, 60-t) Lars Spurkland, P.E. Civil Engineer 203 Nest 15i° Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, LspurklandCagci.net SWE OF ALASKA 555 CORDOVA ANCHORAGE, AK 99501 DEPARTMENT OF ENVIRONMENTAL CONSERVATION Phone: (907)269-7519 DIVISION OF WATER Fax: (907) 269-3487 WASTEWATER DISCHARGE AUTHORIZATION PROGRAMS http://www.state.ak.us/dec/ August 8, 2008 Lars Spurkland, P.E. Spurkland Engineering 203 West 15th Ave, Suite 203 Anchorage, Alaska 99501 Re: Grecian Hills Subdivision, Block 1, Lot 1 -South Anchorage - Separation Distance Waiver- ADEC PlanTracking Number 6675 Dear Mr. Spurland: On August 2, 2007 the Department received an engineering plan submittal for the reduction of the separation distance between a Class "C' Public Water System on Lot 2, Block 1 Grecian Hills Subdivision and an on -lot wastewater disposal and treatment system planned for Lot 1 of this same block and subdivision. The required separation distance was requested to be reduced to 100 feet from 150 feet. Drinking water sample results did not detect bacteria and the results were 2.43 mg/1 for total nitrate. The soil investigation indicated silt and silty gravel layers between the planned soil absorption system and the water table. Slopes of both the ground surface and the subsurface layers appear to direct any wastewater flows away from the source well, off the property toward natural drainages. The engineer recommends the reduction in separation distance based upon the information listed above, and the belief that public health is protected even with a reduction to 100 feet. The Department has reviewed the information provided and grants the requested reduction from 150 feet to 100 feet for this location per Wastewater Regulation 18 AAC 72.020. The distances in this waiver are from the submittal. It appears that the distance of 100 feet is from the nearest edge of the wastewater disposal system components to the nearest edge of the existing Class C public water system well. If this wastewater disposal system fails or contamination is traced back to the system, this waiver will be invalid. The wastewater system is for a single family home a new 1,500 gallon septic tank and a new soil absorption system for up to a five bedroom dwelling is being planned for this site. The wastewater system approval for the single family home will be provided by the City of Anchorages Onsite Program. This approval does not imply the granting of additional authorizations nor obligate any state, federal or local regulatory body to grant required authorizations. Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division Director, 555 Cordova Street, Anchorage, Alaska 99501, within 15 days of receiving the decision. Adjudicatory hearings requests must be delivered to the Commissioner of the Department of Environmental Conservation, 555 Cordova Street, Anchorage, Alaska 99501, within 30 days of the decision. If a hearing is not requested within 30 days, the right to appeal is waived. Thank you for your cooperation. If you have any questions please do not hesitate to contact me at 269-7519. Respectfully, William R Rieth, P.E. Environmental Engineer cc: William Smyth, WW, w/o enc. :CORDS Or A KU WR& EOUND FOR LOT 10. COX DRlVE i ®� SII I LDT 4 1 i i LDT 1 ET I I I --- --J L INOM THIS IS NOT A SURnYrD PUT. KU R SEPTIC LOCATIONS TAKEN EROW ON-SITE WATER AND WASTE WATT DEPARTMENT DOCUMENTAMW ALL LOUPOW SHOWN ARC APMOXAU7r, ly i N LET 2 1 t -_ LOS' LOT 1 LOT I 1 � � I 49th } .............. a...� 50 0 50 Ix 150 200 250 300 SCALEr P = 100 FT REVISED JULY 9, 1009 SPURKLAND ENGINEERING GREMN HILLS BLOCK 1 LOT 1 SEPTIC SYSTEM DESIGN 103 W 15TH. AVENUE ADAM ALBORN DATE.• JULY 30, 1007 (NCH. AK. 99501 (907) 179-3916 8161 COX DRIVE SHEET.• 1/3 GRID. 1630 PERMIT #SV070XXX PID A XXXXXXX GRECIANHILLSB1LIwal.DV6 I � ' I LOT 10 I I , I I P III I ' G ' Q I I INSTALL 1300 CAL ADVANT£X TANK V W/ AX20 POD AND 15' X 20' BLD , LENGTH 20 TER WIOTH 15 TEET I TOTAL DEPTH 1.0 TEET , ROCK DEPTH .3 T£ET INSULA770M 2 INCHES I COVER 2 EE£T (MLN) i Ls cl*l LOT 2 I I Proposed hell-�- I� 1 {1� LOT 1 ; i DON LXlSTINC Lata , TANK P£R MOA COOC 1 RCOUIR£M£ � . No COX DRIVE --- r r—� Well III 111 LOT 3 I III i i l i LOT L? I R100.0' LOT 1 i REVISED JULY 9, 2009 SPURKLAND ENGINEERINGGRECIAN HILLS BLOCK 1 LOT 1 SEPTIC SYSTEM DESIGN ANC H. AKK..99501 TH. AVENUE UrADAM ALBORN DATE: JULY 30, 2007 NC (907) 279-3916 11 8161 COX DR/VE SHEET.- 2/3 GRID. 2940 PERMIT # PID # GRECIANHILLSBILI1DV6 V F A 5 M • SLIDE SEI OF 6' OVER THIS CONNEI TO PRI SHEER PROTECT om BRIDGE EXCAV ..._.. SPURKLAND ENGINEERING SEPTIC SYSTEM DESIGN 203 W15th Ave GRECIAN HILLS BLOCK 1 LOT 1 Anchorage Ak 99501 8161 COX DRIVE DATE, JULY 9, 2009 ___ __.. 9 SHEET: 3/4 GRID 2740 I PERMIT / SWO80OXX PARCEL ID / GrecianHll1s8ltlD4rev.dwg I 5.0' 15.0' 5.0' MONITOR WALL ORENCO LIFT SlA11A4 115' OR SC 3/16' HOLES AT 21' ON CENTER 20.0' AVSTALL MONITOR TUBE CONSTRUCT 20' LONG BY 15. 07DE SOK ABSORPnON BED W/ 0.5' ETTECMT DEPTH SEWER ROCK LNSTALL MONITOR TUOC 2 FEET COVER (MLN.) ATTALL 2-BKW WSLRABON WSIALL fXnR 1•A8R1C WSULL ORENCO 1500 GALLON ADVAN71X TANK 1NS1A/1 ORENCI7 AX 20 TREATMENT C/N/T 0.5' EFTECTTVE WASHED SCNTR ROCK 1 115' DG. SCH-40 PVC W/ 3/16' MOLES 24' ON CDM SPURKLAND ENGINEERING I I GRECIAN HILLS BI LII I SEPTIC SYSTEM DESIGN 203 V. 15th AVE 8161 COX DR/VE ANCHORAGE, AK 99501 DATE, JULY 9, 2009 279-3916 SHEET, 4/4 GRID, 2630 PERMIT if SWO90OXX PARCEL ID f GRECIANHILLSSIL1D5W..DWG Municipality of Anchorage Development Services Department Buliding Sa" Division y1 OnSde Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www d anchorage ek. us (907) 3437904 Soils Log - Percolation Test Pertomled For. Alai, A\6re\ Date Perk Legal Description: (;P E0Aty 11iil5 'Rlk\ LT 1 Township, Range, Section: D`1 Vw�J UKWNU Yw1ntH �1 / 9- 0 ENCOUNTERED? /yO o S i IF YES, AT VNMAT DEPTH? L B O,H depth m WSWAmr _ a 11- MmItorina? E 12- Daft: An O� i y,�P • �S� 1/ 49TH A . LARS E. SFU9KLA%'E) 11500 She Plan Reading Date Gross Time Net Time Depth to Water Net Drop (611910-+ 1.05 r.. O nor. B 7 n 0 IleI1 1'35 rN 30 M:n $It2" Z1 ,r (0'�4 " 2'DS foo OW, N Z1/4 1 fr I. 2:35 0 2 PERCOLATION RATE (3, 3 (niftom&a) PERC HOLE DWIETER (O \\ TEST RUN BETXEEN I FT AND_FT COMMENTS Wt S+'>,1(Gd PERFORMED BY: Lws SpVf AAAr1 I _ PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL CERTIFY THAT THIS TEST W4S off THIs DATE. DATE: 6 2 0 Municipality of Anchorage Development Services Department Building Safety Division y1 Onsite Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 w ci anct�orace.ak. us (907) 343-7904 A II Soils Log - Percolation Test Perform d For. Ad am Al lbrrl Date Perk Legal Desaiption: GRECIAN Wis 131k 1 r...1 1 Township, Range, Section. TN#4L Depth (Feet) 1 2- -3- I ENCOUNTERED? 3- 4- Net Drop 5- 5-6 S IF YES, AT WHAT DEPTH? 6- 7. 7. I I , Grade, 1L o r dunitsdrq? 15 V9 E Dab: 11 2:13 X00 ;n WAS GROUND WATER Date Gross Time ENCOUNTERED? p Net Drop 6 rq o � S IF YES, AT WHAT DEPTH? 14 'S/Icp L 6A.N D.PInlsw.wAm._ 1L o r dunitsdrq? 15 V9 E Dab: 11 2:13 _ 1 C�TN � .S�91f 49 �� LARS E. PURSLAND. W Reading Date Gross Time Net Time Depth to Water Net Drop 6 rq o � 1:11 O nl,r, 14 'S/Icp I0 1L (+43 r., 30 M*'N 15 V9 N " 14 3/ja 11 2:13 X00 ;n 151/6 Al it PERCOLATION RATE -JU (nn+ ) PERC HOLE DIAMETER to P1 11,, TEST RUN BETWEEN of FT AND 3 FT COMMENTS Pte, So;t"�P.\ PERFORMED BY: L��i -•rnUr ic1Q�r1b I IIA 4M CERTIFY THAT THIS TEST PERFORMED IN A IH ALLSTATE AND MUNICIPAL GUIDELI ES IN EFFECT ON THIS DATE. DATE: (0 Z! 0 ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE AND iouina loe\ TI IIS MEMORANDUM OF UNDERSTANDING made and entered into as of this Day ofof 20A, by and between C Cou..K1o✓1 , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AW WTS), described as A26.4- located at Grecian N411< Rik 1 (64 1 —,Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an AW WTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals certify that the systems arc adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On -Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On -Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of Sa ($_�_.00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for the life of the AWWTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations, Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. G. Owner agrees to grant the Municipality reasonable access to test and inspect the AW WTS upon 24 hours wTitten notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for AWWTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AW WTS. 7. Nonwaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: Purchasing Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Low. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: By: Date: 11 Q— 1 ci_P-er—� STATE OF ALASKA THIRD JUDICIAL DISTRICT MUNICIPALITY: By: Title: Date: ) ss. The foregoing instrument was acknowledged before me this \Wday of �- 20LR, by (' hnrV n C tat iMIoDn Cay\u� ki&a�M' NO ARY PUBLIC FORIALASKA My Commission expires: Notary Public S.LADENBURC State of NasM My Commission Expires May 7, 2013