HomeMy WebLinkAboutMCMAHON BLK 3 LT 14McMahon
lock
Lo1' :1.4
· / 017-042
-14
o
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page of
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: 0sP101102 PID Number: 017-042-14
Name:
Merit Homes, Inc. Wastewater System: [] New [] Upgrade
Address:
P.O. Box 111982 Anchorage, AK 99511 ABSORPTION FIELD
Phone: Number of Bedrooms:
334-9233 5 [] Deep Trench {7~ Shallow Trench [] Bed [] Mound [] Other:
LEGAL DESCRIPTION Soil Rating: Total Depth from odginal grade:
.9 GPD/Ft2 6.3-7.8 Ft.
Block: 3 Lot: 14 Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe:
McMahon 2.3-3.8 Ft. 4.0 FL
Township: Range: Section: Fill added above original grade: Gravel Length:
1.5-2.5 Ft. 93 Ft.
Well: [] New [] Upgrade Gravel width: Number of lines: Distance between Ii ....
5 Ft. 2 > 10 Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
Private 253 Ft. 253 Ft. 930 Ft2 ASTM D3034 PVC
Ddller: Date Drilled: Static Water Level: Installer: Date Installed:
Alpine Drilling 7/11/2010 141 Ft. Red Dog Excavating 7/22-26/2010
Yield: GPM Pump Set at: Ft. Casing Height Above Ground:
50 183 >1.5 Ft. TANK
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other:
T~To Septic Absorption Lift Holding =ublic/Private Manufacturer: Capacity:
Tank Field Station Tank Sewer Line Anchorage Tank 2,000 GaL
Material: Number of Compartments:
we, >100' >100' N/A N/A >25' Steel Two
Su~aceVVater >100' >100' N/A N/A % ~ LIFT STATION
Size: Manufacturer:
Lot Line >5' >1 0' N/A N/A Gal.
"Pump on" level at; "Pump off" level at: in. High water alarm at:
Foundation >5' > 10' N/A N/A in. in,
Cu[tain Drain None Noted Pump Make & Model Electrical Inspections performed by:
Remarks:
2" Insulation Over North Absorption Trench. BENCH MARK
Location and Description:
Garage Slab
Assumed Elevation:
100.00 Ft.
Inspections performed by: A. Harala Dates: 1st 7/23/2010
Development Services Department Approval 49 r_l:t
Conditional Approval Date:
Reviewed and approved by: ~)//r-' ~/bilE~,,,,~,~ Date: j//:Z..?.~/~,
(Rex' 04/06) - ~' ~ / t !
/
Permit Number: OSP101102
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 -.343-7904
Page 2 of 3
PID No. 017-042-14
FURROW CREEK ROAD
TH7
TH6 TH3
~TH5
S1
I
Alternate Site
Advantex Treatment System
w/25' Long x 3' Wide x 6'
Effective Depth N3sorpUon
Trench.
"E 163.27'
Five Bedroom
Home
Sl 11A. 1'
S2 20,6'
C5 24.2'
C6 56.2'
M1 28.1'
SV 28.0'
C7 39.6'
C8 69.3'
M3 42.6
B
55.6'
60.5'
49.0'
95.0'
56.9'
64.4'
53.9'
99.8'
63.6'
McMAHON SUBDIVISION
LOT 14, BLOCK 5
31,597 S,F.
10' UT1L ESMT.
S 88'05'00"E 163.09'
PLAN
AS
BUILT
SCALE 1' = 30'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP101102
Page 3 of 3
PID No. 017-042-14
99.7
Odginal Grade
97.5
/
/-
Finished Grade
93.7 - --~
89.7 ---/
t
72.5
NO Groundwater
6/28/10
89.7---~
Geotextile Fabric
Drainfield Rock
46' (Trench Length)
SOUTH TRENCH
97.9
93.7
97.9
Finished Grade
93.9 --~
89.9-2
96.2
2" Insulation
Geotextile Fabric
97.6
Odginal Grade
Drainfield Rock
89.9---/
72.5 --"t
No Groundwater
6/28/10
47' (Trench Length)
NORTH TRENCH
PROFILE AS-BUILT
No Scale
93.9
ROM
:Alpin~ Drillin9
FAX NO. :907 345 0202
Nov. 21 2010 10:1?AM P1
Alpine Drilling & Enterprises
Well Log
Permit Number: #SWosp101102 Date of Issue: 7-9-10 Parcel Identification Number: 01704214000
Date Started: 7-10-10 Date Completed: 7-11-10 Is well located at approved permit location? x Yes [] No
Legal Description: McMahon BIk 3 Lot 14
Property Owner Name & Address: Merit Homes LLC
PO Box 111982
Anchorage, Alaska 99511
Borehole Data: Depth (f0
Sell Type, Thickness & Wa~er S~xata From To
Stick-up 0 2
Organics & silt 2 4
Gravelly silt 4 80
sandy silty ~rravel wet 80 91
silt 91 J 02
gravelly silt' 102 179
sandy silty, gravel h20 179 186
silt 186 190
sandy silty gravel h20 190 209
gravelly silt 209 218
.~andy Mlty gravel h20 218 224
silt, 224 238
silty water sand & gravel 238 246
Mit 246 250
water sand & gravel 250 253
Method of Drilling x air rotary [] cable tool
Casing type: steel
Wall Thickness: .250 inches
Diameter: 6 inches Depth: 253 feet
Liner Type: __
Diameter:__ inches Depth: ~ feet
Casing stlckup_abo.ve ground: 2 feet
Static water level (from ground level): 141 feet
Pumping level: 250 feet after
2 hours pumping 50 gpm
Recovery Rate: 50 gpm
Method of Testing: air I~
Well Intake Opening Type:
x Open End [] Open Hole
[] Screened Start __ feet Stopped ~ feet
[] Pertbrations Start __ feet Stopped ~ feet
Grout Type: bentonite gT, qnules
Depth; Start 0 feet
Pump: Intake Depth ~ feet
Pump size __ hp Brand Name
Volume: 2
Stoooed ? fee~
Well Disinfected Upon Completion? x Yes [] No
Method of Disinfection: chlorine tablets
Comments:
Well Drille~.
Alpine Drilling & Enterprises
PO Box 110496
Anchorage AK Alaska
Mark Begich
Mayor
Development Services Deportment
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orq/onsite
(907) 343-7904
Pump Installation Log
9
Well Drilling Permit Number: SWIOll02
Date of Issue: 11/22/10
Parcel Identification Number: O17-042-14
Replacement Only: YES NO
Legal Description
Lot 14, Block 3 McMahon
Property Owner Name & Address:
Merit Homes
Pump Installation Date: 10/9/2010
Pump Intake Depth Below Top of Well Casing: 183 feet
Pump Manufacturer's Name: Grundfos
Pump Model: 15SQE10-220
Pump Size 1 hp
Pitless Adapter Burial Depth: 12 feet
Pitless Adapter Manufacturer's Name: Campbell
Pitless Adapter Installer: Red Dog
Well Disinfected Upon Completion? [] Yes [] No
Method of Disinfection: Recirc
Comments:
Pump Installer Name:
:tarow Pump & Well Service LLC
PO Box l10496,Anchorage, AK. 99511
(907) 346- 9355
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP101102
PID No. 017-042-14
/
88.9J
6" Steel Pipe Pile
Foundation
100.9
_~2,000 Gallon ~9
Septic Tank
96.3 6.1
92.0 /
84.2
TANK LOCATION
ANALYSIS
No Scale
~ ..' ~ -..,. ~
~-......, ................. ~ ......... ~.....~
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchora.qe, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww.muni.or.qlOnsite
Development Services Department
On-Site Water and Wastewater Proqram
**** VARIANCE/WAIVER REVIEW ****
Waiver/t: OSP101276 COSA#:
PID#: 017-042-14
Legal Description: McMahon Block 3 Lot 14
Engineer: Anderson Engineering
Permit: OSP101102
Applicant: Merit Homes.
Your request for a waiver of the required 5 feet horizontal separation fi:om the septic tank to the
foundation has been approved. The approved separation distance is 4.7 feet.
This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
Waiver is Granted: X Waiver is not Granted:
Date:
Name of Revieyv~r
Rec4¢: Amount: Date Paid:
**** VARIANCE/WAIVER REVIEW ****
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP101102
Tax Code Number: 01704214000
Work Type: WellSeptic Initial
Permit Effective Dates: July 09, 2010 to
Design Engineer: ANDERSON ENGINEERING
Subdivision: MCMAHON
July 09, 2011
Site Legal Address: MCMAHON BLK 3 LT 14 G:2835
Owner/Address: MERIT HOMES LLC
PO BOX 111982 ANCHORAGE AK 995111982
Site Mailing Address: 3840 Furrow Creek RD, Anchorage
Lot Size in Sq Ft: 31597
Total Bedrooms:
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Parcel I.D. 017-042-14
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www. muni.org/onsite
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Property owner(s) Merit Homes, inc.
Mailing address P.O. Box 111982 Anchorage, AK
Site address Furrow Creek Road
Day phone 334-9233
Zip Code 99511
Zip Code 99516
Legal description (Sub'd., Block & Lot) McMahon Subdivision, Block 3, Lot 14
Legal description (Township, Range & Section)
Lot Size 31,597 Sq. Ft. N umber of Bedrooms ,.,Fc~cr'CT-/" ¢")
THIS APPLICATION IS FOR ([~ all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. 11/05)
? ~ C) waiver Fees:
~- - ~ ~-¢,/(_~ Date of Payment:
(? /~/'7 ~' ~ ~ Receipt Number:
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
June 28,2010
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 14, Block 3, McMahon Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 14, Block 3, McMahon Subdivision intends to construct a new five-
bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new well and septic system to accommodate the home. The attached
Site Plan and backup documentation identify the location and configuration of the
proposed well and septic system along with the alternate site. Also identified on the
plans are the existing wells and septic systems on surrounding lots. No conflicts exist
between the proposed well and septic system and wells or septic systems on adjacent
lots. Drainage arrows are shown on the site plan showing the grade and direction of
flow on the lot. The drainage pattern will not be changed as a result of this project.
The test holes recently placed on the lot in the area of the absorption trench and
alternate site indicate poorly graded to silty gravel (GM/GP). The percolation rate of the
soil was determined to be 2 to 3 minutes per inch. Siltier material was found at the 7'
level which percolated at 44 minutes per inch. No groundwater was found during the
placement of the test holes and none was noted during the monitoring period. An
application rate of 1.2 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,500-gallon septic tank and 2
new 37' long by 5' wide by 3' effective depth absorption trenches to treat and dispose of
the effluent generated in the house. The elevation of the distribution line in the
absorption trench will be 2.0' below the surface and the total .depth will be 5.0'. A
minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption
trench and 4' over the septic tank. A flow splitter valve will be placed to assure even
flow to each trench.
The ground surface on the lot in the area of the septic system slopes to the north at
approximately 6%. The new trenches will be constructed parallel with the slope as
much as possible in conformance with Municipal requirements. The new septic system
Lot 14, Block 3, McMahon Subdivision
June 29, 2010
Page Two
will be constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
17
Exlstln9
Is'"ti° I
Xistin9~ Well 1 5
/
\\ Existing Well
1
15
12
AREA
MAP
SCALE 1' = 100'
McMAHON SUBDIVISION
LOT 1~-, BLOCK ,.5
51,597 S.F.
FURROW CREEK ROAD
hallow, Ditch Along Roa~
r~o Water ' ~
S 86'40'11"E 163.27'
I I~ 2-4.~. ,on~ x 5' W,deL ~ ~
I I x 4' Effective Depth I~ h~ ~
,il,,,, Im~ ~"~ t~ ~',, ...... 1
~. ~~., i~__w I~ ......
.I J co(2) xFco o sub
~'1 ~'eS?t'Oc GT:iir(~n~)T,4 x~ EL. : 104'
~ I Alternate Site t
~1 Advontex Treatment System/~
w/25' Long x 3' Wide x 6'
Effective Depth Absorption
Trench.
TH2
LEGEND
TH - Test Hole
MT - Monitor Tube
CO - Cleon Out
FSV - Flow Splitter Vmlve
FCO - Foundation Cleon Out
10' UTIL ESMT.
S 88'05'00"E 163.09'
Proposed
Well
11-11
SITE
PLAN
SCALE 1' = 30'
4700
DEPTH
(feet)
1
2
3
4
5
6
7--
8
9
11
20.
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT Iz., E3LOCK 5, MCMAHON SUBDIVISION
PERFORMED FOR: MERIT HOMES
DATE: 5/28/2010 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. HARALA
TEST HOLE 3
OB/OG
SLOPE
SILTY GRAVEL
GM/GP
SILTY GRAVEL
SILTIER W/DEPTH
WAS GROLTND WATER ENCOUiN~i%,I~BD? No
IF YES ~ WHAT DEPTH2
DEPTH OF WATER AFTER MONITORING: NONE
DATE OF MONITORING: 6/29/2010
POORLY GRADED SAND
SP
BOH @ 18'
SITE PLAN
SEE SITE PLAN
&% ___---
ATE
5/2~
GROSS TIHE NET TIHE DEPTH
ToI
READING (MINUTES) (MINUTES)(INCHEs)WATERI NET(iNCHEs)DROP
TEST HOLE PRESOAKED PRIOR TO TESTING:
1 13:20/13:30 l0 8.38/12.82 4.44
2 13:32/13:42 10 8.25/13.00 4.75
3 13:44/13:54 10 8.19/13.44 5.25
4 14:26/14:36 10 8.38/12.88 4.50
5 14:43/14:53 10 8.25/12.88 4.63
6 15:02/15:12 10 8.12/12.69 4.57
i
PERCOLATION RATE: 2.2 (MrS/rNCH) PERC. HOLE DIA. 8
TEST RUN BETWEEN: 4.0 FT. and 5.0 FT.
(iNcI-mS)
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED. BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 6/28/2010
&700
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
11
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST /
LOT iz+, BLOCK ,_~, MCMAHON SUBDIVISION
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 5/28/2010
PARCEL ID#:
MERIT HOMES
PROJECT No.:
TECHNICIAN:
TEST HOLE 3
OB/OG
SILTY GRAVEL
GM/GP
SILTY GRAVEL
SILTIER W/DEPTH
A. HARALA
GM
SLOPE
SITE PLAN
SEE SITE PLAN
WAS GROUND WATER ENCOUNTERED? NO
DEPTH OF WATER AFTER MONITORING: NONE /-4- % ----------'
DATE OF MONITORING: 6/29/2010 ID
POORLY GRADED SAND
SP
BOH @ 18'
DEPTH TO
DATE READING GROSS TIME NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
6/28 1 13:58/14:28 30 !6.31/7.06 0.75
2 14:29/14:59 30 6.19/6.88 0.69
3 15:17/15:47 30 6.25/7.00 0.75
PERCOLATION RATE: 40 (MIN~CH) PERC. HOLE DIA. 8 .(INCHES)
TEST RUN BETWEEN: 7.0 FT. and 8.0 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 6/28/2010
~700
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
11
1
1
1
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 5/28/2_010
PARCEL ID#:
LOT I&, BLOCK ,5, [vlCMAHON SUBDIVISION
MERIT HOMES
PROIECT No.:
TECHNICIAN: A. HARALA
TEST HOLE 4
OB/OG SLOPE
SILTY GRAVEL
GM/GP
SITE PLAN
SEE SITE PLAN
SILT/SILTY GRAVEL
ML/GM
WAS GROUND WATER ENCOUNTERED? No
IF YES @ WHAT DEPTH?.~ S
DEPTH OF WATER AFTER MONITORING: NONE i ~'% -'---'-----
DATE OF MONITORING: 6/29/2010 ~
DEPTH TO
DATE READING GROSS TIME NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
6/28 1 14:42/14:52 10 8.63/14.19 5.56
2 14:55/15:05 10 8.50/13.50 5.00
3 15:06/15:16 10 8.56/14.12 5.56
4 15:19/15:29 10 8.25/13.88 5.63
5 15:32/15:42 l0 8.31/13.94 5.63
6 15:45/15:55 10 8.44/13.94 5.50
POORLY GRADED SAND
SP
BOH @ 18'
PERCOLATION RATE: 1.8 (MIN/INCH) PERC. HOLE DIA. 8 (INCHES)
TEST RUN BETWEEN: 4.0 FT. and 5.0 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST .PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 6/28/2010
z, 7 0 0
13[!P-l'l-{
(feet)
1
2
3
4
5
6
7
8
9
11
MUNICIPALITY OF ANCI-4ORAGE
DEVELOPMENT SERVICE...; DEPAR1-PIEN'F
BRAGAW STREET ANCHORACSE, AK c:)951c)-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: Lo]- I/q-, BLOCK ~5, NlCNIAHON SUBDIVISION
PERFORMED FOR: MERIT HOMES
DATE: 7/22/2010
PROJECT No.:
TECHNICIAN:
PARCEL ID#:_
A. HARALA
0B/OG SLOPE
S,I TY GRAVE_
GN/GP
SiLT/SiLTY GRAVEL
NL!Gh'I
WAS GROUND WATER ENCOUNTERED? ,. ,%0
IF YES ~ WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING:
DATE OF MONITORING:
300RLY GRADED SAND
SP
NIONE
,,~_% Vx. .~. ......... :..~..4c~,~
--" %'--'"'
................. ......
I".:...'
~HICHAEL E. ANnE~SDN
Professional Ensinee~ Stamp:
SITE PLAN
SEE E;-E --'LAN
E
DATE READING GROSS TI, HE NET T NE DEPTHwA.i FRTO NE ¥ DROP
_ (PIlNUTES) { (MINUTES) (rNCH~S) ':INCHES)
i I TEST HOLE PRESOAKED PRIOR T0 TEST!i~:
6/28 [ 1 14:42/14:52 10 8.63/14.19
b'-- I 2 14:55/15:05 10 8.50/13.50
[ {3 15:06/15:16 10 8.56/14..12
( /4 15:19/,15:29 10 8.25/1o.88
PERCOLATION RATE: _(MIN/INCH) PERC. HOLE DIA. 8 fINCHES)
TEST RUN BETWEEN:12.0 FT. andl3.0 FT.
B0H @ 2_5'
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERC. ~ATE I TO ,53 MINUTES PER INCH.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCOI~_DANCE WITtt ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 7/22/2010
4700
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
11
1
1
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-(::)650
LEGAL DESCRIPTION:
PE~ORMED FOR:
DATE: 7/25/2010
?ARCEI, ID#:
I
SOILS LOG - PERCOLATION TEST I
LOT 1/-,., BLOCK 3, [vlCHAHON SUBDIVISION
OB/OG
SILTY GRAVEL
GM/GP
MERIT HOMES
PROIECT No.:
TECHNIC~N:
TEST HOLE 6
I
WAS GROUND WATER ENCOUN~D? I
· ~S ~ WHAT DE.H?
DEP~ OF WA~R ~TER MON~O~NG:
DATE OF MON~O~NG:
A. HARALA
SLOPE
No
NONE
SITE PLAN
SEE SITE PLAN
4% -------
DEPTH TO
DATE READING GROSS TildE NET TildE WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
7/23 1 10:09/10:19 10 2.13/6.25 4.12"
2 10:20/10:30 10 2.25/6.38 4.13"
3 10:31/10:41 l0 2.06/6.06 4.00"
4 10:42/10:52 10 2.13/6.13 4.00"
5 10:53/11:03 10 2.25/6.25 4.00"
6 11:04/11:14 10 2.13/6.13 4.00"
PERCOLATION RATE: 2.5 .~N~CH) PERC. HOLE D~. 6 (rNCHES)
TEST RUN BETWEEN:7.0 FT. and8.0 FT. ~
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERC; RATE I TO 5 MINUTES PER INCH.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 11/22/2010
4700
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
11
1
1
1
1
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 9951c)-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 14, BLOCK ,5, MCMAHON SUBDIVISION
PERFORMED FOR: MERIT HOMES
DATE: 7/24/2010 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. HARALA
OB/OG
TEST HOLE 7
SLOPE
SILTY GRAVEL
GM/GP
WAS GROUND WATER ENCOUNTERED? No
IF YES ~ WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING: NONE
DATE OF MONITORING:
SITE PLAN
SEE SITE PLAN
------
DEPTH TO
DATE READING GROSS TIME NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
7/24 1 1:14/1:24 10 1.56/6.13 4.57"
2 1:25/1:35 10 1.50/6.00 4.50"
3 1:36/1:46 10 1.38/5.50 4.12"
4 1:47/1:57 10 1.50/5.62 4.12"
5 1:58/2:08 10 1.38/5.50 4.12"
6 2:09/2:19 10 1.50/5.62 4.12"
PERCOLATION RATE: 2.4 (MIN/rNCH) PERC. HOLE DIA. 6 .(rNC}-mS)
TEST RUN BETWEEN:7.5 FT. and8.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERC. RATE I TO 5 MINUTES PER INCH.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 11/22/2010
Municipality of Anchorage
Devalopment Services Department
Building ,Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
5~t Anchorage, AK 99519-6650
~ www. muni.org/onsite
i~F~0 (907) 343-7904'
APPROVAL
CERTIFICATE OF ON-SITE SYSTEMS
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-042-14 COSA# ~_..
Expiration Date:
1. GENERAL INFORMATION
Complete legal description Lot 14, Block 3, McMahon Subdivision
Location (site address) 3840 Furrow Creek Road Anchorage, AK 99516
Current Property owner(s) Merit Homes, Inc.
Mailing address P.O. Box 111982 Anchorage, AK 99511
Day phone 334-9233
Lending agency
Day phone
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, COSA will be held by DSD for pickup.
NUMBER OF BEDROOMS: Five (5)
TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class __ Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding Tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify.~hat based on the information
obtained frorg~b~ Mun c pality of Anchorage files and from my investigation an~ih~pection, the on-site water
supply and~':W~tewater d sposal system is(are) in compliance with all applicabl~,~Jni~ipal and State codes,
ordina ,.r~.~.a~d regulations in effect at the time of installation. "~.:~,.'
N~ Firm Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
bedrooms.
DSD SIGNATURE
~ Approved for ~'
Disapproved.
Conditional approval for
Date 11/21/2010
,,,~ :~'~. . . ..... ..q
~, ~;. ~.~1 .'.~
bedrooms, with the following stipulations:
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
By:
(Rev. 11/05)
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
Municipality of Anchorage'
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description:
A. WELL DATA
Well type Private
Date completed 7/11/10
Total depth 253 ff.
Lot 14, Block 3, McMahon Subdivision
IfA, B, or C provide PWSID #
Sanitary seal (Y/N) Y
Cased to 253 ft.
FROM WELL LOG
Parcel ID: 017-042-15
Date of test 7/11/10
Static water level 141
Well production 50
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL
Arsenic: N/D ug/I
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 2,000 gal.
Foundation cleanout (Y/N) Y
Date of pumping New Const.
C. ABSORPTION FIELD DATA
Date installed 7123-25/2010
Length 93 ft.
Total depth 7.7-10 ft.
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) >18 in.
AT INSPECTION
g.p.m.
Nitrate 8.43 mg/L
Date of sample: 11/12/10
Number of Compartments Two
Depression over tank (Y/N)
Pumper
Soil rating (g.p.d./~ or ft2/bdrm) .9 GPD/SF
Width 5 ft.
Eft. absorption area 930 ft2 Monitoring tube
g.p.m.
Other bacteria o colonies/100 mL
Collected by: A. Harala
Date installed 7/23/2010
Cleanouts (Y/N) Y
High water alarm (Y/N)
Date of adequacy test New Const. Results (Pass/Fail) __
Fluid depth in absorption field before test in. Water added
Elapsed Time: · min. Final fluid depth in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date
N
System type 5' Wide Trench
Gravel below pipe 4 ft.
Y Depression over field N
For bedrooms
~ gal. New depth in.
g.p.d.
LIFT STATION
Date installed
"Pump on" level at
Datum
in.
E. SEPARATION DISTANCES
Fo
Size in gallons
"Pump o~ level at__
Cycles tested
in.
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot >100'
Absorption field on lot >100'
Public sewer main N/A
Sewer/septic service line >25'
Animal containment areas >50'
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
in.
On adjacent lots >100'
On adjacent lots >100'
Public sewer manhole/cleanout
Holding tank N/A
Manure/animal excrete storage areas
N/A
>100'
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main N/A Water service line >10'
Wells on adjacent lots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >10' Building foundation >10'
Water Service line >10' Surface water >100'
Curtain drain None Noted Wells on adjacent lots >100'
COMMENTS:
Absorption field >5'
Surface water >100'
Water main >10'
Driveway, parking/vehicle storage 2'
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 11/21/2010
COSA Fee $ _~._~ '/' ~> C~
Date of Payment /I/~.'7../~ ~
Receipt Number {~ {~ ~'7 7 ~
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
PLAT NO. 65-86
McMAHON SUBDIVISION
LOT 14, BLOCK $
31,597 S.F.
FURROW' CREEK ROAD
S 86°40'11"F 163.27,
SEPTIC SYSTEM
55,2'
WELL
43.5'
10' UTIL. ESMT.
S 88°05'00.E 163.09'
1"=20'
~ I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED.
SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO
JEFF A. GASTALDI, R.I-S. DETERMINE THE EXISTENCE OF ANY EASEMENTS,
'2000 E. DOWUNG RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-54-54- UNDER NO CIRCUMSTANCES SHOULD ANY DATA
(;RID DATE HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABUSHIN(~ BOUNDARY OR FENCE UNES.
2835 10/25/2010
.... ANCHORAGE RECORDING DISTRICT, ALASKA
F.B. JOB NO.
NOTE: NO CORNERS SET THIS DATE,
10-08 MS143
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Nitrate Advisory
Certificate of On-Site Systems Approval # OSC 101315
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 3, Lot 14 of
McMahon subdivision. This inspection revealed a nitrate concentration of
8.43 milligrams per liter (mg/L) was reported for the property's well water
sample. The Environmental Protection Agency (EPA) has established a
maximum contaminant level (MCL) of 10.0 mg/L for public drinking water
systems. While private wells are not subject to this regulation, EPA
standards are based on existing health information and can therefore be used
to gauge the relative quality of water from private wells. Please see the
attached "Nitrate Fact Sheet" for important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.