Loading...
HomeMy WebLinkAboutCHUGACH PARK ESTATES BLK 2 LT 17Chugach Park states lock 2 Lot [7 051-481 -12 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSPl11060 05148112O00 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: May 17, 2011 to May 16, 2012 Design Engineer: NORTH RIM ENGINEERING Subdivision: CHUGACH PARK ESTATES Site Legal Address: CHUGACH PARK ESTATES BLK Owner/Address: BERGERON PAUL L 19823 TULWAR DR CHUGIAK AK 995676353 2 LT 17 G:1161 Site Mailing Address: Lot Size in Sq Ft: 54501 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. ,.,,,ell Date: Date: 05/10/20~ 09:03 90769~7026 NR~MENG PA~£ 01 Municipality of Anchorage Developmant Servicas Departmant Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P,O. BOX 196650 Anchorage, Alaska 99507 www.muni,o~glonsite (907) 343~7904 ON-SITE SEWEPJVVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O~ I "H ~ I.- I'Z.- Legal description (Sub'd., Block & Lot) ~--W~ Legal description (Township, Range & Section) Prope~y owner(s) MailingaddressZ~~~oSS ~ ~'~ O~.~ZipCode Zip Code Number of Bedrooms Lot Size ~q,_~OI Sq. Ft. THIS APPLICATION IS FOR ([] all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN.' Initial Upgrade Renewal I certify that the above information is correct, I further certify that this application is being made for a Single Family Dwelling and is in ac~cor_dance w~h applicable Municipal Codes. (Signature of property owner or authorized agent)/~7 Permit/Rush Fees: Receipt Number: (Rev. ~ U05) Waiver Fees: Date of Payment; Receipt Number: TP, RIM ' E~[NEER NG MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel northrimeng@aol.com Date: 5/9/11 To: MOA On-Site Services Subject: Chugach Park Estates, Block 2, Lot 17 Septic System Design Number of Pages: A new house, water well and wastewater system are planned for the subject lot. The test hole showed excellent sandy gravel to 14', and no groundwater. The design calls for a new water well, trench, new septic tank & private sewer lines. Private water wells serve the area lots and are shown in drawings. Please review the wastewater system design & water well location for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Thanks-Steve Chugach Park Estates, Block 2, Lot 17 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a new 3-bedroom, single family home. This is an established subdivision and most of the neighboring lots are developed. These lots are large and are served by private water wells. No adverse impacts are expected from development. No conflicts to the other lots will take place by this septic system and water well construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed sandy gravel soil. An application rate of 1.2 GPD/FT2 with 0.5 reduction factor for utilizing a 5' wide trench. Trench Length = 375 FT2/5 'x .5 reduction factor = 37.5'; 1 line ~ 38'. No bedrock was encountered. Monitoring revealed no groundwater. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. · Two compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. · 5' minimum between the tank and bed. 10' to property lines. · 3' of cover or insulation is required for trench; an equivalent of 1" insulation for 1' foot soil cover. · Tank & solid pipe must be set on well compacted, stable soil. · 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. · All cleanouts must extend to at least ground level. · In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. · Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain- rock. · Drain rock to be ½ inch to 2 1/2 inch screened. Drain rock to be distributed uniformly throughout the trench. · Perforated pipe to be installed level with perforations down. · Silt barrier (filter fabric) to be installed above the drain rock. · Smeared trench sides must be raked or scarified before drain rock placement. · The finish grade must be mounded to promote drainage over the trench. · Insulation must be placed over any pipe installed under driveways or parking areas. · Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, · Sewer Service Line is minimum 2% slope. · Septic Tank to be pumped every two years or when required. · Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel northrimeng@aol.com Date: 6/7/11 To: MOA On-Site Services, J. Crewdson, PE Subject: Chugach Park Estates, Block 2, Lot 17 Septic System Design Revision Number of Pages: 3 Jay, During the 1st inspection, it was discovered that excessive clean gravel was present in the trench lower 3 feet. We are submitting the following revision which was coordinated by MOA field representative Jeff Poet. The maximum depth is 4.5 feet which will place the absorption field in the sandier soil strata. The new trench length was calculated ~ Trench Length = 375 FT2/5 'x .7 reduction factor = 52.5'; 1 line ~ 53'. Please issue the approval of the revised design. Thanks-Steve E '9- Z 0 0 C 0 c- +~ ~ S .._1 o£ ~ 05 x= > z~_~ C.9 0 E 'T' %1.-- C 0 ¢ o~ Q) o~ > 0 O~ 0 C~ OW i, ~ 0 U E o~ Y U 0 U 0 0 0 0 [ ~ ~J 0 0 E 0 II Z Z Z Z IxL-RT ?IM ~ E.N,G_,~?EERING SDILS LOG - PERCOLATION TEST Date PerFormed: 5/2/10 PerFormed For: Leanndra Ross Lega[ Description~ Chugach Park Estates, BEock 2 Lot 17 p - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 1E~ - 13 - 14 - 15 - 16 - 17 - 18 - 19 - PO - Pi - DEPTH (FEET) F///////~ Or 9anic '...... ;...'.:. ':.::. ':. ,,.: :' .'~ .',~,]' .,' T.H. Location: See Attached Design Gpave( Groundwater? No Depth Water Depth AFter Monitorinq,None Dote: 5/9/il ~ Date Gross Time Net Time Depth Ne~c Drop 1 5/E: 0 5,5' -- P 5/2 10 10 rain, 10,5" 5,0" 3 5/~ 12 5,5# -- 4 5/P ~P 10 rain, 10,5" 5,0" 5 5/2 25 -- 5,5,, -- 6 5/E~ 35 10 min, 10,5" 5,0" 7 5/P 37 -- 5,5" -- 8 5/~ 47 10 min, 10,5# 5,0" 9 5/2 50 -- 5,5" __ 10 5/~ 60 10 mir, 10,5" 5,0" PepcoEotion Rote B min,/inch Pepc HoEe Diameter 6" Test Run Between 3' ond 4' Comments: Pr'eso~ked, PerFormed ByNorthRim Eng, I -~% CERTIFY THAT THIS TEST WAS PerFormed in Accordance with A~( 3tate/Municipa~ Guide(ines in EFFect BN THIS DATE, DATE: 4/13/11 iWO~ THRIM ~.;'....',~,"..~,, i TESTHDLELDG ~.*...*?i~..~:..*.~ T H 1 ENGINEERING ~ ..... ~i ' ' ~o~.~,.~o~ '"~~"~ GEOTECHNICAL ~'~ ~ 5/s/ii June 7, 2011 Municipality of Anchorage Building Safety Division On-Site Water and Wastewater 4700 Elmore Drive Anchorage, Alaska 99507 Dear Sirs, I would like your consideration and approval to owner install the sewer system for my new single family residential construction project on Lot 17, Blk2, Chugach Park Estates. I have over 40 years of residential construction experience to include the installation of on-site septic systems. I have a friend helping me with equipment and a qualified engineer. I would also appreciate your review of the revised wastewater plan which includes a sand liner for the septic. Please call me if you have any questions 907 351 6514. Thank you, Paul L. Bergeron