HomeMy WebLinkAboutCHUGACH PARK ESTATES BLK 2 LT 17Chugach Park
states
lock 2
Lot [7
051-481
-12
Permit Number:
Tax Code Number:
Work Type:
On-Site Water & Wastewater System Permit
OSPl11060
05148112O00
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: May 17, 2011 to May 16, 2012
Design Engineer: NORTH RIM ENGINEERING
Subdivision: CHUGACH PARK ESTATES
Site Legal Address: CHUGACH PARK ESTATES BLK
Owner/Address: BERGERON PAUL L
19823 TULWAR DR CHUGIAK AK 995676353
2 LT 17 G:1161
Site Mailing Address:
Lot Size in Sq Ft: 54501
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
,.,,,ell
Date:
Date:
05/10/20~ 09:03 90769~7026 NR~MENG PA~£ 01
Municipality of Anchorage
Developmant Servicas Departmant
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P,O. BOX 196650
Anchorage, Alaska 99507
www.muni,o~glonsite
(907) 343~7904
ON-SITE SEWEPJVVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O~ I "H ~ I.- I'Z.-
Legal description (Sub'd., Block & Lot) ~--W~
Legal description (Township, Range & Section)
Prope~y owner(s)
MailingaddressZ~~~oSS ~ ~'~ O~.~ZipCode
Zip Code
Number of Bedrooms
Lot Size ~q,_~OI Sq. Ft.
THIS APPLICATION IS FOR ([] all that apply):
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
THIS APPLICATION IS AN.'
Initial
Upgrade
Renewal
I certify that the above information is correct, I further certify that this application is being made for a
Single Family Dwelling and is in ac~cor_dance w~h applicable Municipal Codes.
(Signature of property owner or authorized agent)/~7
Permit/Rush Fees:
Receipt Number:
(Rev. ~ U05)
Waiver Fees:
Date of Payment;
Receipt Number:
TP, RIM
' E~[NEER NG
MEMO
Steve Eng, PE, PH
P.O. Box 770724, Eagle River AK 99577
(907) 694-7028 tel
northrimeng@aol.com
Date: 5/9/11
To: MOA On-Site Services
Subject: Chugach Park Estates, Block 2, Lot 17
Septic System Design
Number of Pages:
A new house, water well and wastewater system are planned for the subject lot. The test hole
showed excellent sandy gravel to 14', and no groundwater. The design calls for a new water well,
trench, new septic tank & private sewer lines. Private water wells serve the area lots and are
shown in drawings.
Please review the wastewater system design & water well location for the single family home. I
have included design plans & specs, design guidelines, & soil tests. If there is need for additional
information or clarification please give me a call.
Thanks-Steve
Chugach Park Estates, Block 2, Lot 17
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: This is a new 3-bedroom, single family home. This is an
established subdivision and most of the neighboring lots are developed. These lots are
large and are served by private water wells. No adverse impacts are expected from
development. No conflicts to the other lots will take place by this septic system and water
well construction. The easements are located on the drawing and are not encroached
upon. Soil tests revealed sandy gravel soil. An application rate of 1.2 GPD/FT2 with 0.5
reduction factor for utilizing a 5' wide trench. Trench Length = 375 FT2/5 'x .5 reduction
factor = 37.5'; 1 line ~ 38'. No bedrock was encountered. Monitoring revealed no
groundwater.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
· Two compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet.
· 5' minimum between the tank and bed. 10' to property lines.
· 3' of cover or insulation is required for trench; an equivalent of 1" insulation for
1' foot soil cover.
· Tank & solid pipe must be set on well compacted, stable soil.
· 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation
wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two
adjacent opposing cleanouts between the tank and the absorption field, not more than
10' from the tank positioned to provide cleanout access towards the tank and towards
the absorption field.
· All cleanouts must extend to at least ground level.
· In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
· Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain-
rock.
· Drain rock to be ½ inch to 2 1/2 inch screened. Drain rock to be distributed uniformly
throughout the trench.
· Perforated pipe to be installed level with perforations down.
· Silt barrier (filter fabric) to be installed above the drain rock.
· Smeared trench sides must be raked or scarified before drain rock placement.
· The finish grade must be mounded to promote drainage over the trench.
· Insulation must be placed over any pipe installed under driveways or parking areas.
· Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
· Sewer Service Line is minimum 2% slope.
· Septic Tank to be pumped every two years or when required.
· Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal)
MEMO
Steve Eng, PE, PH
P.O. Box 770724, Eagle River AK 99577
(907) 694-7028 tel
northrimeng@aol.com
Date: 6/7/11
To: MOA On-Site Services, J. Crewdson, PE
Subject: Chugach Park Estates, Block 2, Lot 17
Septic System Design Revision
Number of Pages: 3
Jay,
During the 1st inspection, it was discovered that excessive clean gravel was present in the trench
lower 3 feet. We are submitting the following revision which was coordinated by MOA field
representative Jeff Poet. The maximum depth is 4.5 feet which will place the absorption field in
the sandier soil strata. The new trench length was calculated ~ Trench Length = 375 FT2/5 'x .7
reduction factor = 52.5'; 1 line ~ 53'.
Please issue the approval of the revised design.
Thanks-Steve
E
'9-
Z
0
0
C
0 c-
+~
~ S
.._1
o£ ~
05 x= >
z~_~
C.9 0
E
'T'
%1.--
C
0 ¢
o~
Q) o~
>
0
O~
0 C~
OW
i,
~ 0
U
E
o~
Y
U
0
U
0
0
0
0
[
~ ~J 0
0
E
0
II
Z
Z
Z
Z
IxL-RT ?IM
~ E.N,G_,~?EERING
SDILS
LOG - PERCOLATION TEST
Date PerFormed: 5/2/10
PerFormed For: Leanndra Ross
Lega[ Description~ Chugach Park Estates, BEock 2 Lot 17
p -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 -
1E~ -
13 -
14 -
15 -
16 -
17 -
18 -
19 -
PO -
Pi -
DEPTH
(FEET)
F///////~ Or 9anic
'...... ;...'.:. ':.::.
':. ,,.: :' .'~ .',~,]' .,'
T.H. Location: See Attached Design
Gpave(
Groundwater? No
Depth
Water Depth
AFter Monitorinq,None Dote: 5/9/il
~ Date Gross Time Net Time Depth Ne~c Drop
1 5/E: 0 5,5' --
P 5/2 10 10 rain, 10,5" 5,0"
3 5/~ 12 5,5# --
4 5/P ~P 10 rain, 10,5" 5,0"
5 5/2 25 -- 5,5,, --
6 5/E~ 35 10 min, 10,5" 5,0"
7 5/P 37 -- 5,5" --
8 5/~ 47 10 min, 10,5# 5,0"
9 5/2 50 -- 5,5" __
10 5/~ 60 10 mir, 10,5" 5,0"
PepcoEotion Rote B min,/inch Pepc HoEe Diameter 6"
Test Run Between 3' ond 4'
Comments: Pr'eso~ked,
PerFormed ByNorthRim Eng, I -~% CERTIFY THAT THIS TEST WAS
PerFormed in Accordance with A~( 3tate/Municipa~ Guide(ines in EFFect
BN THIS DATE, DATE: 4/13/11
iWO~ THRIM ~.;'....',~,"..~,, i TESTHDLELDG
~.*...*?i~..~:..*.~ T H 1
ENGINEERING ~ ..... ~i ' '
~o~.~,.~o~ '"~~"~ GEOTECHNICAL ~'~
~ 5/s/ii
June 7, 2011
Municipality of Anchorage
Building Safety Division
On-Site Water and Wastewater
4700 Elmore Drive
Anchorage, Alaska 99507
Dear Sirs,
I would like your consideration and approval to owner install the sewer system for my
new single family residential construction project on Lot 17, Blk2, Chugach Park Estates.
I have over 40 years of residential construction experience to include the installation of
on-site septic systems. I have a friend helping me with equipment and a qualified
engineer.
I would also appreciate your review of the revised wastewater plan which includes a sand
liner for the septic.
Please call me if you have any questions 907 351 6514.
Thank you,
Paul L. Bergeron