MUNICIPALITY OF ANCHORAGE
Development Services DepartmentPhone: 907-343-7904
On -Site Water & Wastewater Section i : _ ]
Fax: 907-343-7997
Well Drilling Permit Number:
Pump Installation Log
Date of Issue:
Parcel Identification Number: 015 272 - 18
FLegal Description Block Lot Property Owner Name & Address:
MCCORMICK. TAMMY
SIEFKER 42 B-1 4101 E 112TH AVENUE
W2 ANCHORAGE, AK 99516
Pump Installation Date: 06 - 13 - 2022
Pump Intake Depth Below Top of Well Casing: 155 feet
Pump Manufacturer's Name:
MYERS
Pump Model: 3NFL72-8-P4-02
Pump Size: .75 hp
Pitless Adapter Burial Depth: 14
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer:
feet
CAMPBELL
Well Disinfected Upon Completion?Yes ElNo
Method of Disinfection: PELLETS
Comments:
Pump Installer Name:
ANCHORAGE WELL & PUMP SERVICE
Company: 7640 KING STREET
ANCHORAGE, AK 99518
_Mailing Address: _ 907-243-0740
City: State: Zip:
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
3 +, 7.w. 11+ ae
SWI# id a J-1
nen n � nn.n
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP111081 PID Number: 015-272-18 ❑ New ❑✓ Upgrade
Name:
John and Tami McCormick
ABSORPTION FIELD
❑ Deep Trench ❑✓ Shallow Trench E] Bed ❑Mound
Address
4101 E. 112th Avenue Anchorage, AK 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
748-4863
5
1.2GPD/SF
8.6 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4.5 Ft.
Gravel depth beneath pipe
4�OFt.
Subdivision Block Lot
Siefker No. 2 W2 B-1
Fill added above original grade
0-1 Ft.
Gravel length
63 Ft.
Township Range Section
Gravel width
S.OFt.
Beds: Number of Lines
Distance between lines
I Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
630 Ft'
1
Ft.
Well
>100'
>100'
N/A
N/A
125'
TANK O Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,50OGal.
Surface water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
Steel
Two
NA
Foundation
>5'
>10'
N/A
NIA
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
None
Noted
Remarks
Pump on level at
irr
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL HousetotankD3034 Tank.to D3034
Installer
drainfield
Willie's Trucking and Excavcation
Drainfield HDPE GO/MT D3034
Inspector A. Harala
BENCH MARK (Assumed elevation) 100.Oft
Inspection 1�619/11 619111
Location and description
dates: 2"d
Back Deck. Northeast Corner.
3,a 4,„
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
ME...,....,<,� +e
Conditional Approval: Date
49n
.................................. r
s
4381 LS.,
��f r�•
� >
+�IfB
Approved Date ��'�
PROrissio
ti'A��"�e�
Inspection Report_1-1-,F2.0c �
I Permit Number. OSP111081
4xK:1101
S1 — Septic Vent
C4 — Clean Out
MI — Monitor Tube
TH — Test Hale
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT Page 2 of 4
4700 South Bragaw Street Anchorage. AK. 99519-6655 — 343-7904
On—Site Wastewater Disposal System or Well Inspection Report
PID No. 015-272-18
SIEFKER SUBDIVISION NO. 2
LOT B1
0 E. 112TH AVENUE
POWER LINES M r— 10' UTILITY EASEMENT
O Afternate site
TH1
0 e TH P1
C5 ca
M1
LOT B-1
Sl
A I B
S1 15.4 35.8
Ne; S2 30.0 34.7
Existing Septic System C5 35.5 35.9
Deconniesioned on
November 23, 2010. C4 41.1 42.1
Mobile Home M1 38.9 36.7
. .. • Gam9e
GRAVEL DRIVEWAY 0OTECT WELL RADIUS
Existing
Well
LOT B -1A
UTIlLfr
LOT 12 1 LOT 11 1 LOT 10 1 LOT 9
PLAN AS BUILT
SCALE 1' = 60'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP111081
93.3
a
U
89.3—
Gallon
Tank
92.7
a
97.8
Finished Grade
Existing Ground
Geotextile Fabric
Drainfield Rock
/81.8
f No Groundwater
6-9-11
63' (Trench Lenqth)
PROFILE AS -BUILT -
NO SCALE
Page 3 of 4
PID No. 015-272-18
U
49th
AEL E. ANDERSON
No. CE -4381
..9-V-rAw`F
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSPl11081
01527218000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 EImore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
U pg rade
Permit Effective Dates: June 03, 2011 to June 02, 2012
Design Engineer: ANDERSON ENGINEERING
Subdivision: SIEFKER #2
Site Legal Address: SIEFKER#2 LT B-1 W2 G:2635
Owner/Address: OLSON FAMILY TRUST
OLSON M C & V E/TRUSTEES PO BOX 211521 ANCHORAGE AK 995211521
Site Mailing Address: 11215 JEROME ST, Anchorage Lot Size in Sq Ft:
Total Bedrooms:
93308
5
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The well must be documented prior to Final Inspection Report approval.
Received
Issued By:
Date: '
Date: -~ ~-~/"~'/~/"'
UNICIPALITY
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
OF ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. .¢.~i'~'-
Propertyowner(s) ~"~'N-~i..,- ~t ~ ~1~ Dayphone
Mailing address
Site address
Legal description (Sub'd., Block & Lot) Lo-r' 1~" J, ~ ~..
Legal description (Township, Range & Section)
Lot Size c7'~ 3~; ~, Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR: THIS APPLICATION IS AN:
(~;~ all that apply)
Initial
Absorption Field '~
Septic Tank [~ Upgrade ,~
Holding Tank [] Renewal []
Privy
Private Well
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
'P'br~i~/Rush Fees: .............. Waiver Fees:
Date of Payment: ,"'~ , ;:.'~-:' , ,, Date of Payment:
Receipt Number: ' ' .:"::;": "ii::. Receipt Number:
Permit No. ~',,':',. ~,- ,,, ' .... :' '. Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 )
ANDERSON ENGINEERING
P,O. BOX 240773
ANCHORAGE, AK 99524
522.7773 677.7766 (FAX)
May 25,2011
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot B-l, Siefker Subdivision No. 2
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot B-l, Siefker Subdivision No. 2 intends to construct a new five-
bedroom home on the lot at some point in the future. The lot is currently occupied by a
mobile home. We are therefore requesting a permit be issued for the construction of a
new septic system to accommodate the home and the existing mobile home. An
existing well is currently in use on the lot. The attached Site Plan and backup
documentation identify the location and configuration of the proposed septic system
along with the alternate site. No existing wells or septic systems are closer than 100'
from the proposed septic system. Drainage arrows are shown on the site plan showing
the grade and direction of flow on the lot. The drainage pattern will not be changed as
a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated poorly graded gravel with sand and silt (GP/SP). The percolation rate of the
soil was determined to be between 1 and 5 minutes per inch. Groundwater was found
during the placement of the test holes at 13' to 15' below the surface and remained at
that elevation during the monitoring period. An application rate of 1.2 gallons per day
per square foot was used in the design of the absorption system. We are proposing to
place a new 1,500-gallon septic tank and a 63' long by 5' wide by 4' effective depth
absorption trench to treat and dispose of the effluent generated in the house. The
elevation of the distribution line in the absorption trench will be 5' below the surface and
the total depth will be 9'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be
placed over the absorption trench and 4' over the septic tank. The existing mobile
home will be connected to the septic system until the new home is constructed.
The ground surface on the lot in the area of the absorption trench slopes gently to the
Lot B-l, Siefker No. 2
May 25, 2011
Page Two
north at a grade approximating 3%. The new trench will be constructed parallel with the
contours of the slope as much as possible in conformance with Municipal requirements.
The new septic system will be constructed a minimum of 100' from all wells and any
surface water and 10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
I I
LOT A-gB
LOT A-go
~( E. 112TH AVENUE
LOT 12 LOT 11 LOT 10 LDT ~
I--lA
AREA NAP
SCALE 1' = 100'
,_q~FP-KFR, ~. SUBDIVISION NC. ,_ '~
LOT B 1
152,199 S.F.
~ E. 112TH AVENUE
POWER UNE
-~ N 90'O0'O0'E: 314.42'
i0' U~lUl'Y
~l [ 7~-~,- ~r ................... -7 ..................................................
1~ ., ......... ~
33.0, = I~ ~ ~ P1 t ~1 ~omi~lon~
+ I ~ ....... T':~ F' sh~ ..~
o ~ i~..:..~.~ :, ..: ~.:.. /
I ', :-:'.' .--.. -- -'- /
I ~ ' - ~ - .',-'--"' -- /
~',,,~-*-,. - . - .: /
I
I
lo' ~
N ~'42"E 314.~' I
LOT 12 LOT 11 LOT 10 LOT
I-lA
LEGEND
SV - Septic Vent
CO Cleon Out
MT - Monitor Tube
TH - Test Hole
NOT, E:
No Slopes Oreoter Than 25% Are Located Within 50'
of the Absorption Trenches.
SITE
PLAN
SCALE 1' = 60'
LOT B1, SIEFKER SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Five Bedroom Home 5' Wide Trench System
Perc. Rate: 1-5 Min./Inch 1,500 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
5 Bedrooms * 150 GPD/Bedroom = 750 SF Absorption Area
750 SF/1.2 GPD/SF/5 SF (Width) *.5 (Red. Factor)= 62.5 LF Trench Length
THEREFORE: Construct a 63' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 5' Below Original Ground Surface. Total Depth to be
9' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
ell
keotextile Fabric
4" Perforated
PVC (Holes Down)
Coarse ~r~i;fi~ide~;i;cification)
TYPICAL 5' WIDE TRENCH SECTION
-- ~ ~.--~c~ .... ---~.;~,~
NOTE: Grade Are~ Over Trench to Drain Away. ~ 49th
Minimum 6 Separation From Bedrock. ~.....~ ........................... ~....~
M'nimum 4' Separation From Groundwater. ~l~
Minimum 100' Separation From Private Wells in the Area. ~'"~;;;;;';;'~;;;;;~;'"'~
Minimum 100' Separation From Su~ace Water or Streams: ~%~ No cs-.~
SOILS LOG - PERCOLATION TEST
TEST HOLE
SLOPE SITE PLAN
OR ROOT MASS
1
112th AVENUE
2--
~ 1 O' Util Esmt
~ ~ , /SEPTIC SYSTEM
7 SP/GP BROWN SAND/ I ~
8-- GRAVEL '" ' 1
9- ~ WELL
I
14 -- BROWN WAS GROUND WATER SLOPE
GM/SM SAND/SILT/ ENCOUNTERED? ~
15 ~ GRAVEL
MIXTURE IF YES, AT WHAT TH
~6 DEPTH? -0-' X
BOH
17 -- DEPTH TO WATER AFTER
MONITORING? -DRY-
~8 DATE: 11/30/10
~ WATER
DATE PERFORMED: 11/23/10 READING ' DATE CLOCK NETTIME LEVEL NETDROP
TIME
READING
1 11/23/10 10:49 --- 3.30 ---
2 10:59 10 MIN 6.92 3.62
3 11:00 --- 3.30 --
4 11:10 10 MIN 6.81 3.51
5 11:11 --- 3.30 --
6 11:21 10MIN ! 6.76 3.46
CLOCK WATER
READING DATE TIME NET TIME LEVEL NET DROP
READING
1 11/23/10 10:49 --- 3.30 ---
2 10:59 10 MIN 6.92 3.62
3 11:00 .-. 3.30 -_
4 11:10 10 MIN 6.81 3.51
5 11:11 __. 3.30 ._
6 11:21 10 MIN 6.76 3.46
PEROLATION RATE 2.9 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 3.5 FT AND 4.5 FT
COMMENTS: Test hole excavated by A+ HOME SERVICES. Prec hole was presoaked.
Test run for one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC, LLC oF ",,
FOR REVIEW ONLY P.0. BOX 102954 ANCHORAGE, AK 99510 __.~.'~?..~., .......... ~,,.9/¢?~, 12/16/10
PHONE (907) 272-8218 FAX (907)272-8211 y~.-' ~7.tT?,z Scgle
~ :' ~9th ~ ~ ~ NTS
Siefker ~2, Lot B-1 W2 ............. ~o.~ } ~.~ 015-272-18
OIson Fomily Trust
~'~ CE-8~49 ~.'~ PERMIT NO.
11215 Jerome ST
SOILS LOG ANCHORAGE, AK 99516 ~,~ss~(...~ Sheet
~x~ 1 OF 1
Performed For:
Legal Description:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
www. ci.anchoraqe.ak.us
(907) 343-7904
Soils Log - Percolation Test
Seifker Subd., No. 2, L B1
I '~;~ ........
Date Pedormed: April 26, 201
Township, Range, Se~ion:
Slope Site Plan
2-
3-
4-
5-,
6-
7-
8-
9-
10-
11
12
1
14-
15-
16-
17-
18-
19-
20-
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT DEPTH?
Depth to Water After
Monitoring?
Yes
s
-13.0' L
O
-13.0' P
E
Date: 5 14/11
Reading Date Gross Time Net Time Depth to Water Net Drop
PERCOLATION RATE ~ ~1~ (minutes/inch)
TEST RUN BETWEEN - 4.0 FT AND
Perc Test Cavity was pre-soaked
PERC HOLE DIAMETER 9"
- 4.5 FT
PERFORMED IN ACCORDANCE With ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Performed For:
Legal Description:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
www. ci.anchoraqe.ak.us
(907) 343-7904
Soils Log - Percolation Test
Seifker Subd., No. 2, L B1
Slope
Township, Range, Section:
Site Plan
2,
3-
4-
5-
8-
9-
10-
12-
14-
15-
16-
17-
18-
20-
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT DEPTH?
Depth to Water After
Monitoring?
Date:
Yes
-15.5'
P
-15.0' E
5/14/11
Reading Date Gross Time Net Time Depth to Water Net Drop
PEROO~TION ~TE ~,O~ ~/i~ch) PERC HOLE D~METER 9"
TEST RUN BETWEEN
Perc Test Cavity was pre-sOaked
- 5.0 FT AND - 5.5 FT
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~"- ~.- iv