400%
200%
100%
75%
50%
25%
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T14N R2W SEC 11 LT 60 N2
T14N R2W Sec. 11 Lot 60 N2 #050-261-22 01 MunicipaRy oTAnchorage Development Services Department Building Safety Division = -m On-Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.el.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: OSP1 11301 PID Number: 050-261-22 Noma: RALPH SHIPMAN Wastewater System: ❑ New ■ Upgrade Address; VFW ROAD *EAGLE RIVER, AK 99577 ABSORPTION FIELD Phone: No. of Bedrooms: (907) N/A 3 ❑Deep Trench ■Shallow Trench ❑Bed ❑Mound 1:1 Other LEGAL DESCRIPTION Soil Rating: O c � Total Depth from anginal grade: 9. CPD/Sq. Ft. 6 MAX Ft. Block: lot: Subdivision: Depth to pipe bottom from original grade: Grovel depth beneath pipe: — N2 OF LOT 60 — 4.43 Ft. 2.17 Ft. Township: 14N Range: 2W Section: 1 1 Fill added above original grade: Gravel length: SEE DWG. Ft 21+ e, WELL: ❑ New ❑ Upgrade Grovel width: 5 Number of lines: 1 Distance between fines: — FL FL Classification (Private, &S,C): Total Dep • Cased To:(eEOROCK) Total absorption area: Pipe material: *\r Ft Ft. 150+ SO. FL D 3034/ F-81 O/SCH 40 Driller. V Date Drilled: Static Water Level: FL Installer. Data installed: SOUTH FORK CONSTRUCTION 10/27-28/11 TAN K Yield:Pump Set At: Casing Haight Above Ground: GPM Ft. Ft. SEPARATION DISTANCES []Septic ❑ Holding H S.T.E.P. ❑ Other* To Septic Absorption Lift Holding Public/Private Manufacturer. GREER Capacity in gallons: 1500 From Tank Field Station Tank Sewer Unes Well 100'+ 100'+ 100'+ — 25'+ Material: STEEL Number of compartments: 2 Surface Water *75' 100'+ *75' - - LIFT STATION Lot Line 5'+ *1' 10'+ — — Size In gallons: Manufacturer. 1500 QUANICS STEEL Foundation 51+ 10'+ 5'+ — — 'Pump on' level at: Pump off' at: High water alarm at: 1 TIMER TIMER 46" Curtain Drain NONE KNOWNP—SE-41—T Pump Make & Model: Electrical Inspections performed by: �l Sln�{r SOS {g�-A.., Remarks: THIS IS A QUANICS AEROCELL SYSTEM BENCH MARK Location and Description: *WR # OSP111302 SCREEN DOOR THRESHOLD OLD TANK WAS PUMPED, CRUSH, AND COMPLETELY ABANDONED PER UPC. Assumed Elevotiom 100.00 Inspections performed by: G EG, Ltd. Dates: 1st 1x/27/11 ENGINEERS SM QooboO 2nd 10/28/11 3rd 10/28/11 Q-• Development Services Department Approval. -s��� - .. ............� Conditional approval: Date: • • • • • • • • • • • • • • • • • •p OQ f re A. G rness,. ,J oQ �po CES Reviewed and approved b OS" Date: % �4ea °rot{eSS�od�o (Rev. 4/06) ��Opp000 C o'l Ves-s)`o,-, -Pn) n 6k /JG9 T� -�z �k Gq T � �pn.�ved f Q //1 / 1 & /3 (JLt'<2A GARNESS ENGINEERING GROUP, Ltd ENGINEERING = SALES - CONSULTING November 2, 2018 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O, Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 On an_ cs, Advanced Tm7tmenr Sys[cm D - - Ref: T14N, R2W, Section 11, Lot 60 N2 (10247 VFW Road, Eagle River, AK) Memo concerning converting CAT III AWWTS to CAT II AWWTS septic system To whom it may concern: The permitted septic system was installed on the referenced property and started up in 2011. ARM Septic Services, LLC, has recently checked the monitoring tube in the drainfield and found it to be dry. In order to simplify the operation and maintenance of the system, we are proposing that this unit be permanently configured as a CAT I I system, Our justifications are as follows: • The receiving soil had percolation rate of 9.2 minutes per inch. Given this percolation rate, a 3.0 gpd/sq.ft. application rate is required for a Cat II system. The home has 3 bedrooms, so 150 sq./ft. of absorption area is required for a CAT II system (450 gpd / 3.0). The existing 2008 drainfield has 150+ sq./ft. of absorption area. The following information should supersede the application rates outlined in GEG's original design dated 10/17/2011 and the approved On-site Wastewater Inspection Report dated 6/28/2012: - Allowable application rate (for Cat ll system): 3.0 gpd/sq.ft. At this time. we request that your department approve a CAT II configuration to be used at the referenced property. Upon your concurrence, we will have ARM Septic Service, LLC, either leave the Jandy valve actuator in the discharge position; or have them completely remove the actuator from the valve and leave it in the open position. We will also have them place a CAT II sticker on the control panel. In addition to this, we are also recommending that ARM add an aeration system to the lift station to 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Page 2 of 2 oxygenate the wasNwater prior to the Aerocell unit. This will enhance the performance of the system arld uld provide long term benefits to the longevity of the system. Si Jiff P�! G ` m6s.5. P E., M.S. Presidedt 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. garnessengineering.com Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSPl11301 05026122000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: October 25, 2011 to October 24, 2012 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T14N R2W SEC 11 Site Legal Address: T14N R2W SEC 11 LT 60 N2 G:0051 Owner/Address: SHIPMAN RALPH S 10247 VFW ROAD EAGLE RIVER AK 995778032 Site Mailing Address: 10247 VFW RD, Eagle River Lot Size in Sq Ft: 31200 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Original signed and notarized maintenance agreement required for final inspection report approval. Received B~~~.- / .'~ Issued By: :~. V~;' 't / Date: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907- 343-7997 Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. Property owner(s) RALPH SHIPMAN (C/O SOUTHFORK CONST.) Mailing address 10247 VFW ROAD *EAGLE RIVER, AK 99577 Day phone 694-4351 Site address 10247 VFW ROAD *EAGLE RIVER, AK 99577 Legal description (Sub'd, Block & Lot) T14N, R2W, SEC 11, N2 OF Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms LOT 60 THIS APPLICATION IS FOR: ( [] all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: 75' WAIVER- SURFACE WATER TO PROPOSED 1500 GALLON STEP TANK. 1' WAIVER- LOT LINE TO PROPOSED DRAINFIELD. I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) ~ ~ .~z~© -- Waiver Fees: ~r ayment: i~'l,[.~( 1/ Date of Payment: Receipt Number: L/'..)~ .~k_~ ~ Receipt Number: Permit No. ~" ¢/~ ~0 ~ Waiver No. (Rev. 01/11) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GiENERAL CONTRACTORS October 17, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for T14N, R2W, Sec 11, N2 of Lot 60 To whom it may concern: The existing 3 bedroom house is served by a private well and septic system. The existing septic system was installed prior to the formation of the Municipality of Anchorage. For the purpose of selling the house in the future, the owners are requesting to upgrade the septic system to meet current MOA standards. We are proposing to that a new 1500 gallon STEP tank, a 650 Aerocell unit with Quanics controls, and a 5-wide trench type drainfield be installed. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There is a surface water within 100 feet of the proposed septic system. See Section 5 requesting a waiver. 4. TOPOGRAPHY: As can be seen on the attached design and detail drawing the proposed drainfield is located at the toe of a steep slope but the topography around the drainfield is relatively flat. In short, there are no slope concerns. 5. WAIVER REQUESTS: As can be seen on the attached design drawing, the proposed 1500 gallon STEP tank is to be located 75+ feet from a surface water (Meadow Creek). We are requesting your department grant a 75 foot waiver from the proposed STEP tank to surface water. The following are mitigating factors for the issuance of this waiver: · The S.T.E.P. tank will be a 3/16" deep burial tank. The S.T.E.P. tank will be equipped with a high water alarm that will alarm audibly if there is an elevated condition in the tank. The control panel for the tank will also be equipped with a remote alarm system that will notify a certified service provider if an alarm condition occurs. · The area for the new S.T.E.P. tank is in a very visible area with heavy vegetation and a driveway between the tank and the surface water. If an overflow did occur, the condition would be noticed immediately and the problem resolved quickly. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.garnessengineering.com Based upon these mitigating factors, it is our opinion that there is minimal risk with the granting of this waiver. ~ As can be seen on the attached design drawing the proposed drainfield is located near the south lot line. Due to site constraints and setbacks from surface water we are requesting your department grant a one (1) foot lot line waiver to the south lot line. We are unaware of any adverse impacts this installation and the granting of these waivers would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Th~nk you for your assistance. Sincerely, "--geff'~:ef/A~cGarhess, ,]P. E., M.S. Pres'i/dent .? ~ NO TE: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 9950%1259 Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.garnessengineering.com SCALE: 1' = 100' EXISTING SEPTIC (APPROXIMATE / / / L / / N 1/2 OF LOT 54; T14N, R2W, SEC. 1 // NO ENCROACHMENT CONCEI:~IS / / / / / / / / S 1/2 OF LOT 54; / T14N, R2W, SEC. 11 / NO ENCROACHMENT CONCERNS / / / / L MEADOW HO__US__E__ N 1/2 OF LOT 55; I T14N, R2W, SEC. 11 J NO ENCROACHMENT CONCERNS I /I /I s or T14N, R2W,/~EC. 11 NO ENCROACHMENT COI~CERNS / / / / - /__/ /..J ,,/ ~'~' / / SEPTIC UPGRADE. SEE DESIGN, PAGE 2 OF 4 S 1/2 OF LOT 60; T14N, R2W. SEC. 11 \ I 100' WELL RADIUS APPROX. LOCATION \ \ I / / LOT 59; T14N, R2W, SEC. 11 GAR.NESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENi E. 'RJBOR R~3~Do SUITE 101 * ~%'HORAGF., N( 99507 ~' PHONE (907)337-6179 * FAX (907)338-3246 * WI~SITF.: ,~.gomes~lneeflng.cem PREPARED FOR: IPHONE NUMBER: RALPH SHIPMAN (C/O SOUTHFORK CONSTo)I 694-4551 LEGAL DESCRIPTION: T14N, R2W, SEC 11, N2 OF LOT 60 TYPE OF WORK: SITE PLAN FOR SEPTIC SYSTEM UPRGADE PAGE NUMBER: 1 OF4 IDI~WN BY: J.L.M. DATE: 10/17/2011 NO ENCROACHMENT CONCERNS "A-T,-GOrn esso: DESIGN CRITERIA: NOTE: THE CONTRACTOR SHALL HAVE THE NUMBER OF BEDROOMS: ;3 SOUTH LOT LINE, THE 75 FOOT SURFACE GALLONS PER DAY (GPD): 450 WATER SETBACKS, THE 1 O0 FOOT PERCOLATION RATE/S: 9.2 MIN./INCH SURFACE WATER SETBACK AND ALL WELL PROPOSED APPLICATION RATE: .3.0 ALLOWABLE APPLICATION RATE: 5.0 RADII FLAGGED BY A REGISTERED LAND MINIMUM DRAINFIELD SQ.FT.: 150 SURVEYOR PRIOR TO CONSTRUCTION. DRAINFIELD DESIGN: MAXIMUM DEPTH: 6 FEET MAX. O ANY POINT WIDTH: 5 FEET LENGTH: 21 FEET M.O.A. APPROVED SAND FILTER: N/A NOTE: THE AREA AROUND THE DRAINFIELD EFFECTIVE: 2 FEET Lot 54 SHALL BE GRADED AND MOUNDED SO THAT THE REDUCTION FACTOR: 0.7 DRANFELD S NOT ABLE TO BE DRIVEN ON. ACTUAL SQ.FT.: 150 GEG, Ltd. HAS A 7 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN, TO OBTAIN A COPY OF THE LETTER / CONTACT GEG. BY PROCEEDING FORWARD CONSTRUCTION AND MAINTENANCE WITH THIS INSTALLATION, THE ENGINEER, FA.~FMFNT---~ WELL DRILLER, CONTRACTOR AND / \ PROPERTY OWNER AGREE THAT tHEY 50' BI-bi ROADWAY I~ESERVATION HAVE READ THESE SPECIFICATIONS AND ! ~ ~-'"~ ~ ~ AGREE TO ACCEPT THE TERMS AND / ....~ ~ E XISTING WELL 100' CREEK SETBACK 650 AEROCELL UNIT ~ ~ ~ .GAYNESS ENGINEERING GROUP, Ltd. C/O SOUTHFORK CONSTRUCTION 694-4.351 I 2 OF 4 ~'f/~ ~ LEGAL DESCRIPTION: DRAWN BY: SEPTIC SYSTEM UPGRADE DESIGN 10/17/2011 GARNESS ENGI'NEERIN G GROUP, Ltd CONSULTANTS & :GENERAL CONTRACTO1R~ 5701 E. TUDOR ROAD, SUITE 101 · ANCHORAGE, AK. 99507 * PHONE: (907)337-6179 * FAX: (907)358-5246 * WEBSHE: gomessenglneering.com LEGAL DESCRIPTION: PERFORMED FOR: ISOIL LO(; - PERCOLATION TESTI T14N, R2W, SEC 11, N2 OF LOT 60 RALPH SHIPMAN (C/O SOUTHFORK CONST.) DATE: TEST HOLE #1 ORGANICS AND LOAM MIX SOIL CLASSIFICATIONS 9/,30/11 GM (HARDER WITH DEPTH) ON GC ~ SW SP SC ORG NL CL OL NH CH OH DEPTH TO GROUNDWATER DATE 11' 9/50/11 11' 10/4/11 I1' 10/10/11 SCALE: I I 1" = 100' SEE ATTACHED SITE PLAN DATE READING CLOCK NET TINE WATER LEVEL NET DROP TINE (HINUTES) READING (INCHES) 10/4/11 1 2:10 - 6.00- - 2 2:40 50 2.75" 3.25" 3 2:40 - 6.00,, _ 4 5:10 30 2.75" 3.25" 5 5:10 - 6.00- - 6 5:40 50 2.75" 5.25" PERCOLATION RATE 9.2 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES TEST RUN BETWEEN 3 FT. AND 4 FT. A FOUR HOUR PRESOAK WAS PERFORMED: [~YES SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: COMMENTS:PERCOLATION READINGS ARE EQUAL TO OR BETTER THEN 1/16 OF AN INCH. [~]NO JODY MAUS PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERF~)RMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: l~:/I 7/~i 113 -13 -q C 113 Z '13 C -0 r- rrl --I Z I L I 0 C -0 0"0 O< Z(3 Z mO (3O I-- {~ .-~ ~ c O~ [ z -> x m --I ~ 0 0 C Z ~ 0 Z C DATE: IDRAWN BY: 10/17/2011 IJ.L.M. LEGAL DESCRIPTION: T14N, R2W, SECTION 11, N2 OF LOT 60 TYPE OF WORK: DESIGN OF QUANICS AEROCELL SYSTEM PREPARED FOR: IPHONE NUMBER: C/O SOUTHFORK CONSTRUCTION I 694-4,351 'IUOO~ R~qO. SUI~ 101. AN(340P, A0~ ~ g9,~07 PHONE: (gO7) 337-et7O/FAX: (907) 338 324~ * ~ TEST HOLE 4' MONITORING TUBE 650 AEROCELL 4" CLEANOUT-~ FINAL GRADE---,X~ GRAVEL DRIVEWAY 2 FEET 01 EFFECTIVE 5 FEET WIDE .I GRADE 6 FEET DIEEP MAX. AT ANI POINT GROUNDWATER O 11' ON 10/10/2011 B.O.H, AT 12' (NO BEDROCK) GARNESS ENGINEERING GROUP, Ltd. --.. - .... '. '~'~ CONSULTANTS & GENERAL CONTRACTORS ~701 F- TUDOR ROAD, surl~ 101 * ANCHORAGe, AK 99507 * PHONE (g07)~37-6179 * FAX (907)3~8--3246 * ~ wtre.garne~en~ineerin~cern PREPARED FOR: RALPH SHIPMAN ~PHONE NUMBER: PAGE NUMBER: C/O SOUTHFORK CONSTRUCTIONI 694-4551 4 OF 4 LEGAL DESCRIPTION: I DRAWN BY: T14N, R2W, SEC 11, N2 OF LOT 60 I J.L.M. TYPE OF WORK: ' - J DAT~"I 0/17/2011 DETAIL OF DRAINFIELD / / / ! I CONSTRUCTION AND MAINTENANCE I MISC. BOOt< 102, PAGE 55 I BLM ROADWAY RESERVATION ----' - -'--- ~ I MEADOW CLF. ANOUT DRIVEWAY REsInENC£ WfI'H FUU,. DECK 34.3' S~rS~K / $ 152,8' Lof'~,~O J I I PLOT PLAN AS BUILT X SCALE 1" = ;50' GRID NW 51 ProJeof No. 11-150 / & Associates, inc. (go7) 522-647 Phone Reglsfered Land Surveyors (907) 522-4625 Fax k.e.n.,,Ol?,ng, eurvey.com / JonathanOlangeurvw. com , I hereby oerllfy that i have surveyed the following described property: B.L.M. LOT 60, SECTION 11, T14H, R2W, S.M., ALASKA, LESS THE SOUTH 152.8' Anchorage Re~ordlng District, Alaska, and thef fha imprevemenfa ~lfuafed thereon are within the properly line, and do not encre~ch onto the properly adjacent thereto, that no Improvements on the pmperl7 b/lng adjacent thereto enoroaoh on the surveyed premise, and fhaf them are no m~dwaye, fl~nsmlsalon lines or other visible easemenf~ on said prepeHy exeapf as Indl~fed hereon. Dated this fha .-&~-~h Day of ~.'.'.'.'.'.'.'.'.'~l~- , "4/~, at ~J~horaga, Alaska If la fha responsibility of fha owner fo defermlna tho existenoe of any easements, oovsnonfs, or reatrlaflone whioh do not appear on fha reeo~ed subdivision plat, 11500 Daryl Avenue, Anehorage~ Alaeka 99515-3049 Page 1 of 1 Crewdson, James A. From: Sent: To: Cc: Subject: Attachments: Jay, Jody Maus [Jody@garnessengineering.com] Tuesday, October 25, 2011 12:41 PM Crewdson, James A. Jeff Garness; Pierce Blewett; Sonja Blewett RE: T14N R2W SEC 11 LT 60 N2 L11150a1_2000v2 PlotPlan (1).pdf Attached is the as-built survey performed by Lang and Associates. I talk to Jonathan Lang today and he said he did a thorough research of the property and assured me that the survey is correct. In regards to the Maintenance agreement, based upon our phone conversation today, you stated that you would accept a signed (but not notarized) copy of the agreement for now so the permit could be issued, but that you would an original, notarized agreement must be sent to you in the near future. The owner's daughter who has power of attorney lives near Fairbanks, but is an hour away from the nearest notary. Her husband has stage 4 cancer and can't be left alone. They have a doctor appointment on Thursday and should be able to get this notarized at this time. In the meantime, they will fax a signed copy into Southfork Constructions office and we will make sure you get a copy of this. The original maintenance agreement should be mailed and into your office by the end of next week. We request the permit be issued today so that the system can be installed at this time. Thank you, Jody Maus Consultant/Senior Engineer Technician Garness Engineering Group, Ltd. 3701 East Tudor Road, Suite 101 Anchorage, Alaska 99507-1259 Ph: 907-337-6179 Fax: 907-338-3246 email: iodv@~arnessengineering.com From: Crewdson, James A. [mailto:CrewdsonJA@ci.anchorage.ak. us] Sent: Monday, October 24, 2011 1:33 PM To: Jody Maus Subject: T14N R2W SEC 11 LT 60 N2 10/25/2011