HomeMy WebLinkAboutHIGHLAND TERRACE LT 6Highland
Terrace
Lot 6
#050-312-13
Municipality_ of Anchorage -
- —
-Ory-Site Water and Wastewater Program (907) 343-7904 Page ` of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: 05P13y3311 PID Number: 050 31Z-13
Dwelling: 2 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ( New ❑ Upgrade
Name:
EW H a ABSORPTION FIELD
Address Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
1073r)r, N 1: 81_3L P: nR ❑ Other
7.2 GPD/SFJ 30
D pipe invert from original grade Gravel depth beneath pipe
"1 cr h
i Ft.] 'I Z
SEPARATION DISTANCES
I z Ft.
—
Ft.
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total absorption area
5X F1'
Number of trenches
I
Dist. between trenches
Ft.
well
106+
JW4
TANK I@ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
2 /�WIK
Capacity
3S Gal.
Surface Water
NA
Material
FbL'rMf LEVE
Number of compartments
Z
Lot Line
5 r
(Ji 1
FoundationS*
q
10}
LIFT STATION
Manufacturer
/VA
Capacity
Gal.
Curtain Drain
1 50+
1 Sp+
1
Remarks
Pump on level at
Pump off level at
High water alarm at
make and model jElectrical Inspections performed by
PIPE MATERIAL Housetotank '"""`°
Installer
Ata$ drainfield 46$
S6NuETrER TTZrnGKi/✓6 Drainfield�� CO/MT °"
Inspector PE7E7rhfE6/ky� BENCHMARK (Assumed elevation) ft
Inspection Location and description
dates: I";.-:? Zia Z—% 1 N c�C GO/�Nclz �� l ��ItiCj�
3id JO -j.4 0
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Approval:
Approved
Date
Date /1-3-/q
CLEANOUT 1 (FOUNDATION)
TANK CLEANOUT 1
MONITORING TUBE 1
TANK CLEANOUT 2
CLEANOUT 2 \
DOUBLE
CLEANOUT 3 I
CLEANOUT
5
MONITORING TUBE 2
CLEANOUT
4
�P2JALG(tADE
0
I
�
0
I
fo
V
fl7�.iGiNALGRRDE
-
4-:70
2" INSULATION
TRENCH PER DESIGN
6�}7 T
i3oT�innOF: 7ES14C(E
INVERT ELEVATION
POINT I.E. DEPTH
CLEANOUTI 97'-0"
TANK INLET 99E"
TANK OUTLET 96'-5"M0NITORING
WELl1
CLEANOUT2 96'J"
CLEANOUT3 96'-3"CLEANOUT4
78'-0"
MONITORING TUBE 2 10'-0"
CLEANOUTS 76'-0
NOTES: 1. REFERENCE ELEVATION IS 100'-0" AT SE CORNER OF HOUSE.
2. NO GROUNDWATER WAS PRESENT IN EITHER MONITORING TUBE.
3. DRAWING IS NOT TO SCALE.
TITS
DESIGN
DRAWING No.
HEWKO HOUSE
DRAWN
HIGHLAND TERRACE, LOT 6
AB2
AS-BUILTPROFILE
PH
DATE
10-31-2014
"
100' WELL RADIUS
-
WELL
CLEANOUT 1
TANK CLEANOUT 1
POINT 1
MONITORING TUBE 1
POINT
TANK CLEANOUT 2
CLEANOUT 2
- - -
CLEANOUT 3
MONITORING TUBE 2
TH 2A
0.� TEST HOLE #1
TH 2 CLEANOUT
4
CLEANOUT 5
FUTURE ALTERNATE
DRAINFIELD
SWING
TIES
POINT
MT1 metz
TPNHG NGUT1
YO'd` 19'd'
TMK CLE DIJT2
me za'.rc
GI MT2
.I WT3
B1'-0' 3V-V
CLEMWT•
73'ti' 81--V
MONNCRINGTUW2
PW 19B'd'
ML MT
fl9'd` 111$
XWL Ill N9E94IX6 ASE N MEIFA@ e.
O
TIRE:
DESIGN
DRAWING No.
HEWKO HOUSE
DRAWN
HIGHLAND TERRACE, LOT 6
q
AB
AS-BUILTPLAN
PH
1
DAT
10-31/2014
ARCTIC PUMP & WELL INC.
R r- Jim Sullivan
PO sox 770197
eruusvn as Eagle River, AK 99577
crus e tt - (907) 688-2510
(907) 243-2282
Pump Installation Log
Well Drilling Permit Number: osp121205
Parcel Identification Number: 05031213000
Date Of Issue: 9/2112012
Tuesday, September 10, 2013
Legal Description Highland Terrace L6
Property Owner Name Address:
Peter Hewko
Lot: 6
3831 Boek Cir
Block:
Anchorage AK 99507
Pump Installaion Date: 8/26/2013
Pump Intake Depth Below Top of Well Casing: 390 Feet
Pump Manufacturer's Name Franklin
Pump Model: 10JS1P4-2W230
Pump Size: 1
Pitless Adapter Burial Depth: 12 Feet
Pitless Adapter Manufacturer's Name Harvard
Pitless Adapter Installer: ulk
Well Disinfected Upon Completion? Yes
Method of Disinfection: Chlorine
Comments:
Pump Installer Name:
Arctic Pump & Well, Inc.
Tuesday, September 10, 2013
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131334
Tax Code Number: 05031213000
Work Type: Welseptic
Permit Effective Dates: September 20, 2013 to September 20, 2014
Design Engineer: HEWKO" PETER D.
Subdivision: HIGHLAND TERRACE
Site Legal Address: HIGHLAND TERRACE LT 6 G:0155
Owner/Address: HEWKO PETER
3831 BOEK CIRCLE ANCHORAGE AK 995073059
Site Mailing Address: 19355 HIGH BLUFF DR, Eagle River Lot Size in Sq Ft: 74899
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The permit includes waiver OSP121317, allowing the drainfiled to be
constructed on a 30 percent slope.
Special Provisions: C01 revises the septic tank location.
Special Provisions: PRIOR TO CONSTRUCTION: At least one of the test holes shall be deepened
to substantiate there is no impermeable soil within 6 vertical feet of the bottom of the drainfield and
7 -Day groundwater monitoring shall be completed. If the results require a design change, an
approved chnge order shall be issued prior to constructing the drainfield.
'�Th:S ii a. vicetntwa) rlf t7S�1al�Of,
Received By
Issued By:
I
MUNICIPALITY OF ANCHORAGE
e0k.-C
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcell.D. 050-31_2-J3
Property owner(s) _I C� 9EWK0 Day phone 3q6 —1 Vit
Mailing addre
Site address
Legal description (Sub'd., Block & Lot) �1T/i��
,1 a 6
Legal description (Township, Range & Section)
Lot Size _77W �W Sq. Ft. Number of Bedrooms
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field 91' Initial
Single Family (SF)
❑
(wlwo ADU)
Septic Tank Ell'Upgrade ElDuplex
(D)
ElHolding
Tank ElRenewal
Multiple Dwellings
❑
Privy ❑
(SF and/or D)
Private Weil
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
of property owner or authorized agent)
Permit/Rush Fees: NUFeP PPti I-og ,
Date ofd: �i I Ile 113
Receipt Number:
Permit No. os i°13133`�
Permit App_"-: -
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
September 13, 2013
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Watewater Program
PO Box 196650
Anchorage, Alaska 99519
Subject: Renewal of sewer/well permit for Highland Terrace, Lot 6
Dear Sir or Madam:
I would like to request a renewal of the well and septic permit for Lot 6, Highland Terrace. There are no changes to
the proposed system. If you have any questions, please contact me at 346-1616.
Respectfully,
Peter Hewko, PE
3831 Boek Cir
Anchorage, AK 99507
Certified Drilling Log
BILL Sc COLE OC CO dba
�P.O.Box 670269,
ULLIVAN91WATER WELLS, AK 99567 GBII-2759
OWNER OF LAND: Peter Hewko
ADDRESS: 3831 Boek Circle Anchorage 99507
Bore Hole
Data
Depth
From
To
LEGAL DESCRIPTION Highland Terrace Lot 6
DATE: 7/1/13
0
2
Casing Stickup
PERMIT NUMBER: 121205 DATE OF ISSUE: 9/21/12
TAX IDENTIFICATION NUMBER 05031213000
Is well located at approved permit location: ® Yes ❑ No
Method of Drilling: Zair rotary ❑ cable tool
Depth of Well: 400ft
Casing Type: Steel Wall thickness ,250 inches
Diameter: 6 inches, depth 44ft
Static Water Level: 42 feet
Recovery Rate 5 ® gpm ❑ gph
Method of Testing
Well Intake Opening Type: ❑ open end ® open hole
❑Screened Start feet Stopped
Grout Type: Bentonite Chip's Volume:
Depth: from 0 feet, to 20 feet
Well Disinfected Upon Completion: ® yes ❑ no
Method of Disinfection: Chlorine 50PPM
Comments:
Well Hydrofraced
2
4
Overburden
4
21
Hardpan
21
43
Silty Sand & Gravel Tight
43
140
Bedrock Gray
140
260
Bedrock Green
260
307
Bedrock Gray w/ Quartz
307
320
Bedrock Green
320
345
Bedrock Gray w/ Quarts
345
400
Bedrock Gray
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
Matsu Borough: Department of Environmental Conservation.
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121205
Tax Code Number: 05031213000
Work Type: WellSeptic Initial
Permit Effective Dates: September 21, 2012 to September 21, 2013
Design Engineer: HEWKO` PETER D.
Subdivision: HIGHLAND TERRACE
Site Legal Address: HIGHLAND TERRACE LT 6 G:0155
Owner/Address: HEWKO PETER
3831 BOEK CIRCLE ANCHORAGE AK 995073059
Site Mailing Address: 19355 HIGH BLUFF DR, Eagle River Lot Size in Sq Ft: 74899
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: PRIOR TO CONSTRUCTION: At least one of the test holes shall be deepened Q
to substantiate there is no impermeable soil within 6 vertical feet of the bottom of the drainfield
and 7 -Day groundwater monitoring shall be completed. If the results require a design change, an
the drainfield to be
constructed on a 30 percent slope.
Received
Issued By:
OIV406Q Kl-
�j'3/�a Ctl+e 1c�
s%evid kA q p
dated }/3/i3•i.f-
July 3, 2012
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Watewater Program
PO Box 196650
Anchorage, Alaska 99519
Subject: Special Provisions of Permit OSP 121205
Dear Sir or Madam:
In accordance with the special provisions of Permit OSP121205, an additional test hole was excavated adjacent to
test hole 2. This test hole was excavated on June 25, 2013, to a depth of 16' (6' below bottom of drainfield). No
impermeable layers were encountered, and no groundwater was observed. Ground water monitoring was conducted
for 7 days from June 25 through July 2; no ground water was observed in the hole during this time. This additional
information should satisfy the requirements of this special provision associated with this permit.
If you have any questions, please contact me at 346-1616.
Respectfully,
Peter Hewko, PE
3831 Boek Cir
Anchorage, AK 99507
Attachments: Soil Log
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
www. ci.anchorage, ak.us
(907) 343-7904
Soils Log - Percolation Test
. . 6 W ././µ"1 V.
y PCIER DAVID HIEV;10
�j�•
NO. 1'aE'JJWT • �'w,
Performed For: Peter Hewko Date Performed: 6/25/201
Legal Description: Lot 6, Highland Terrace Township, Range, Section:
__2A
Depth
�1�t1<� DIZG't7VTy
o
5rn
w/G KAVEL
0
0
I
12-
13-
14-
15-
16 -
2-13-
14-
15-
16- a
17-
18-
19-
L36 -10F FOO
Site Plan
WAS GROUND WATER
ENCOUNTERED? NO
5
IF YES, AT WHAT DEPTH? N/A
L
Depth to Water After
P
P
Monitoring? NONE
E
Date: 7/2/2013
PERCOLATION RATE (minuteslinch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
COMMENTS Test hole 2A excavated to verify separation to groundwater and impermeable layers. See test hole 2 for percolation test.
PERFORMED BY: Peter Hewko i Peter Hewko CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7/2/2013
Municipality of Anchorage
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.muni.oM/Onsite
Development Services Division
On -Site Water and Wastewater Program
pent 000"t""'10
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSP121317 COSA#: Permit#:OSP121205
PID#:050-312-13
Legal Description: Highland Terrace, Lot 6
Engineer: Peter David Hewko, P.E.
Applicant: Peter Hewko
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the 25% or greater slope has been approved. The approved separation distance is 0.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
..................................................................... a.........
Waiver is Granted: X Waiver is not Granted:
Date: Cia 1/u Approved by: 'A_
Name of Reviewer
............................................•..................................
Rec#: 01558C Amount: $200.00 Date Paid: 9120/2012
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
Mayor Dan Sullivan
ON-SITE SEWERIWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel l.D.fp.W —3q-2 -y-5
+SY"'�\iC YOAAGd.Ct�
Propertyowner(s) tlaETER HEwKO Dayphone 3H616f6
Mailing address 3632 r30EK LL2 A1i6µolzq6,, 4k 9951D9t
Siteaddress 1.932-6 otK 9R- Lc !zWL_7-e
Legal description (Sub'd., Block & Lot) N-LGHI-AAID Mm f;) A _ LoT f2
Legal description (Township, Range & Section)
Lot Size jgjg9 Sq. Ft. Number of Bedrooms_
THIS APPLICATION IS FOR: THIS APPLICATION IS AN:
(® all that apply)
Absorption Field ® Initial
Septic Tank [itj Upgrade ❑
Holding Tank ❑ Renewal ❑
Privy ❑
Private Well
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or
Permit/Rush Fees:
Waiver Fees: O =�
Date of Payment: �`�
Date of Payment: ct
Receipt Number:
Receipt Number: 0 1 5' S` C
Permit No. 5 /��� (aUS
Waiver No. OSpot I 13 f i
G:\Building\On Site\Forms\Client Forms\Permil App_010411.doc (Rev. 1/11)
September 20, 2012
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Watewater Program
PO Box 196650
Anchorage, Alaska 99519
Subject: New sewer/well permit for Highland Terrace, Lot 6
Dear Sir or Madam:
On June 10, 2011 two test holes were excavated on the subject property. Percolation test were performed at these
locations on June 13, 2011. The results of these tests and water monitoring are attached. No groundwater has been
observed in either hole at any point.
We propose to install a 2' wide deep trench septic system on this property. The percolation rate for the test hole
adjacent to the proposed primary drainfield is 5 min/inch, which is within the range allowed for a deep trench
system. For the proposed 4 bedroom house and a 6' deep trench, a length of 42' is required
((4xl50/l.2)/(2x6)--41.7'). The system will have a minimum cover of 4'-0". The proposed site slopes 30%; a
request for a slope waiver is attached.
Due to system depth, we request a special provision to probe the test holes to 16' (6' below drainfield) prior to
construction to verify separation to groundwater and impermeable layers. Probed holes will be monitored for
groundwater for 7 days in accordance with AMC 15.65.06084. Based on well logs and test holes documented on
Lot 5 (South), Lot 7 (West), and Lot 12 (East) of the site which show the nearest impermeable layer 20.5 to 37 feet
below grade and no groundwater encountered to at least 15' below grade (the deepest test hole is on Lot 5 at 15'
with no groundwater encountered), we do not anticipate encountering either groundwater or impermeable layers,
however we understand that proceeding under a special provision is at our risk.
The septic tank for the system will be a 1250 gallon insulated polyethylene tank.
The system will be inspected by a registered engineer 1) when all excavation is completed, and 2) when the septic
system is installed and the system is ready to be backfilled.
The proposed well is West of the house and Northwest and uphill from the septic drainfield. There are no public or
private wells or surface water within a 100' radius of the proposed location. There are no known curtain drains near
the site. We do not expect that there will be any adverse effect on adjacent lots by the development of this system.
If you have any questions, please contact me at 346-1616.
Respectfully,
�V
F '1�
Peter Hewko, PE
3831 Bock Cir
Anchorage, AK 99507
Attachments: On -Site Well and Sewer Application
Request for Slope Waiver for Septic Disposal Field
Site Plan and Absorption Field Detail
Soil Log/ Percolation Test
September 20, 2012
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Watewater Program
PO Box 196650
Anchorage, Alaska 99519
Subject: Request for Slope Waiver for Septic Disposal Field at Highland Terrace, Lot 6
Dear Sir or Madam:
We propose to install a 2' wide deep trench septic system on this property. The slope conditions on the site will not
allow the wastewater disposal field to be located 50' horizontally up gradient from a change in slope to greater than
25%. We propose to install the disposal field in accordance with MOA memorandum dated April 7, 2004. Per this
memorandum, a line at a 25% slope beginning 2.5' above the distribution pipe invert must intersect actual grade a
minimum of 35' horizontally from the point 2.5' above the pipe invert.
The proposed site slopes at 30%. We propose to locate the pipe invert 4'-0" below grade, which will cause the
hypothetical line at 25% slope to intersect the actual slope 36'-0" horizontally from the point above the invert. This
is shown on the wastewater disposal field trench section of the drawing.
Based on the above, we request a slope waiver of zero (0) feet.
If you have any questions, please contact me at 346-1616.
Respectfully,
F;tr_4��
Peter Hewko, PE
3831 Bock Cir
Anchorage, AK 99507
i
/. Tract C
^\\-,.Basis of Bearing
�N8V56'00 -� "•'-
/ 300.02'
PP
C`40'_UTES�
I =T',
jN,� zea „53
I .; -250
• �- PROPOSED
�•1.� `"• �`"�^-'t\I HOUSE
1
1 I � 540' 15 I -•,
a _
I
Lot?
L
PROPOSED 3 = A '�,� '" �• 8
GRAVEL t i •�.. �.� 1-. 1 i \ },�
DRIVEWAY.
`�pROPOSED SEPTIZ,"\ ALTERNATE SEPTIC
`.Lot 6 � � •,..� �- _ \_
6"y.SlA t, 78,222 S.F. 182.3'1
1.80 AC.
Lot 12
PP
246,97,
50°00.1§•W
LUFF E
PP
�OHE M
_ O
Finish Floor Elevation
Upper-914.00' LEGEND
Lower--902.00'
O FOUND PLASTIC CAP ON REBAR �_ g
/ • FOUND 5/8- REBAR
='s
Zone R-S Setback TEST PIT LOCATION
--
comer Lot 0 50' 100' OF A� /1111
Front 50'
Sides 25'
Back 25' Vertical Datum is NAVD88 CORS(98), Geoid12
Survey Date Sept. 2012 •
i * • lli
Plot Plan Lot 6, Highland Terrace Subd., SE 1/4, NE 1/4, S 7, T14N, R1W, S.M. !.-'�
I hereby certify that 1 have surveyed the i ..••• •• ••• .
Del Norte Surveying, Inc. property shown and described hereon and that i9g • G GREER a`4-
no visible encroachments exist except as i°i LS-8033
indicated. It is the responsibility of the owner to �i�/ems'•. g—Z— l2 .••�A��
P.O. am 110%3c
anT oq. unite 99511 determine the existence of any easements, to a .•
(907)5.5 seat Rte. - (907) �5 �2 FAX covenants,
rants, o r restrictions subd which
do not appear `/ 1Pot //41q��N���%%
on
Drawn G. Greer Grid NW0155 Scale 1"=50' Date SEPT. 7, 2012 File No. HEWKO_PP_L6.dwg
O
> O
O
N3V13SV3
kmLLn
mss.
00.0-.031
000+ 33,_0. ,0 -.OZ
m S `0• 33.00
o
rnA
0
I o
5'_0. A
z 5.00 F
ts
w -"1 F" o = 0 38.00 N
m o Z
J Iq � .ZOI O ITI
o
d m Z 5:0, oa < o
s� � Soo 0 0 0
m
32'-0°
Fm
$ Qgp Sz �s 32.00
o z
z
�c c "' c
,g "Q-�40X � v
S
0�
oC 1
,o
m 0
m
m
rn
N z
-i
f
10'-0°
4'-0"
gg
2'-6"
��g A
O
N /
a4 N OpA
., w cNi-'mm>� o c11�TT� NZZ000Dz "mm
y 2 m e m r�nmmz� M22 WEI
z wm r� rloz y�� nr^ aim oy
crn �x m � omz 1n 6 citCW8 / p
i M. _ ON oZm yNo�om omo��rn /
A9 moo N�"Ss z M.2 F
m� .00OL O—mml
m C� r 2 Eam.1 m/ O
�O vOzmN Cr"i Z
N 55 _
7 4 mW �? 47 O O Amm A4 Z O R�1 >A l m
m � /
O DNDm mp
��T`I�m / m
�-4Ed A /
o m
a +
mS > M010
FS
�A
� F` r
sow'
moo
zs'-io 1/2"
S
UMM
un in
o
o -,oz
s oa
28.88
•oa
ro
v
A
m
zzc� 5.00
n
309 �
�
o
czi rrn a �
9�a
A m O O
ITi
m
6�D�
6B.i
oo aoo
o
m k--7
SOO
O�
x o
So
a
o A
z
n>
m
8.00
sed
o
09
O a
—aQp
`dos
X40
~
S Op 30%
OP
Gl
Z Z
mN
S
O9
~ �
m
D
n
S0 iz
D
C
N ~ o
O
I
m O O
O
m r�
z
W
-I
O)
N
Z
41
ID
N
O
'Or -Or
2r_srr
- 0
7
V 4
$
N GJNT
T z�nv
O OOA
O AT1
Z -C IT~1
N�ODZ �
�"c•FiN
10�➢
O
/ �
Y
inNN�
�
n ohm
N
mmmcziz
m<m
cnm Z
D�OOO
O? O> U I V l w
I D
nN
�Zm
a
-
N mfT
NN
F T<
rn O
O
2A�1"-G
0 m
fi
AOZAO
m
D
� ZN
m
o4 e9A T
K m
m T
.14
I
j•
m D�
T A> �
OmA
Z A •A
y�TO�
y Z Z
(n
f T I
AOO�ry
Z I
r N
_
a
� F
Nin N
NN ��rIp
A
TO�mN
:ClA
(-J
A y T
m
Z O
T
ti
O m0
Z Z LZ] O
y
m�
Amm AOI'm
Z
Om n I
m
y T
q'S
- W
47 (rJ
C
-im
y m�C
r /
MO
o
o
zrp
o�:gym
2.4
J
Im-A
z
mm
z,c'�mO
I
rn
rn
00 O N
N m
m m
$ $
A
s
z
ti
K
��
rn
A
oy z➢ A
I
➢
N < O
4
A
o
/
ro
O
D p Z 0
I
/
K i
4
N A
m m
n➢m
I
m�
S=
O
4
m
m
�
o
�o
mm
s
3YY3SV3
�c Allmn
mss oa•a- oz
$o. 33'-0" .0 -,Oz
�s10• 33.00
v
o
N y
�F`o �5.0o p F
�JO,$ z o o -
m yy�^� O 38.00 N
E
zO+�a '�0000
fTl Z s� ,A o
8� � 5�0� EC
o 0
0 it j
S° m
o g�O . o rn o r p rz 321-0,
Fi
.00
x
mmrD
o
OX
p
o _
m o
m V
m
rn
N Z N
- V
10'-0'
4'-0"
pp a
2-6
�v -
Ot
O y G)2 yy�V Dmf�_ m yO
(* p .. 6 1 p
2 m AOrn to tnW /
f 2 mfm py AZm U
-
~om
m �g� p
m000•'• F yoo =Av g n
mcg I I o o—m o�^ 2 z Azz / o
gg 2S m C m rn
z 09 K m c_z Vl � x m zn /
voz rZ^'$n m zp�> y/ m
R o m � We omr^� O om m �/ y m
Z x
MM
p O Z S O_ p � E m / b4 W
CIL
� Nmq
z Azb m
?z�+S2� /
mo m c z
m
rn O m�m
9�.9 •, /
> s pin
lid PC
cc
mm
J ®tel ca
SOILS LOG - PERCOLATION TEST
TH IRM Date Performedi 6/10/11
W INEERING
Performed For: Peter Hewko
Legal Description) Highland Terrace S/D, Lot 6
DEPTH
(FEET)
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 -
12 -
13 -
14 -
15 -
16 -
17 -
18 -
19 -
20 -
Organic T,H, Location, West Test Hole
SM
Silty Sand
w/ Gravel
Groundwater? No
Dense Depth --
Water Depth
After Monitorino.None Datej 6/13/11
#
Date
Gross Time
Net Time
Depth
Net Drop
1
6/13
0
--
5.0'
--
2
6/13
10
10 min.
7,0'
2'
3
6/13
12
--
5.0'
--
4
6/13
22
1 10 min.
7.0'
2'
5
6/13
25
--
5.0'
--
6
6/13
35
10 min.
7,0'
2'
7
6/13
37
--
5.0'
--
8
6/13
47
10 min.
7,0'
2'
9
6/13 1
50
--
5.0'
--
10
6/13 1
60 1
10 min. 1
7,0' 1
2'
21 Percolation Rate 5 min./inch Perc Hole Diameter 6'
Test Run Between 3' and 4'
Comments PrPsnaked. Measurements made to nearest 1/16 inch.
Performed By NorthRim Eng, I CERTIFY THAT THIS TEST WAS
Performed in Accordance with All State/Municipal Guidelines in Effect
ON THIS DATE. DATE; 6/10/11
NOR THRI M
ENGINEERING
PO Box 770724
Eagle Rlx .. Alaska 99577
907.694. 7025
'TESTH❑LE LOG
GEOTECHNICAL
T, H, 2
DOW
6/10/11
S❑ILS
.a
�N INEERING
LOG - PERCOLATI❑N TEST
Performed For; Peter Hewko
Date Performech 6/10/11
Legat Descriptions Highland Terrace S/D, Lot 6
DEPTH
(FEET)
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 -
12 -
13 -
14 -
15 -
16 -
17 -
18 -
19 -
20 -
Organic
SM
Silty Sand
w/ Gravel
Dense
T,H, Location; East Test Hole
Groundwater? No
Depth --
Water Depth
After Monitorina,None Date; 6/13/11
#
Date
Gross Time
Net Time
De th
Net Drop
1
6/13
0
--
5.5'
--
2
6/13
10
10 min.
7,0'
1.5'
3
6/13
12
--
5,5'
--
4
6/13
22
1 10 min.
7,0'
1.5'
5
6/13
25
—
5.5'
--
6
6/13
35
10 min,
7,0'
1.5'
7
6/13
37
--
5.5'
--
8
6/13
47
10 min.
7.0'
1.5'
9
6/13
50
--
5.5'
--
10
6/13
60
10 min.
7.0'
1.5'
21 Percolation Rate 7 min./inch Perc Hole Diameter 6'
Test Run Between 3' and 4'
Comments; PrPsnakPd. MPasurementa made to nParPst 1/16 Inch,
Performed By NnrthRim Fng, I igf CERTIFY THAT THIS TEST WAS
Performed in Accordance with All State/Municipal Guidelines in Effect
ON THIS DATE, DATE; 6/10/11
NOR THRIM syP�E..... '"�, TESTH❑LE LOG
ENGINEERING•i •*• T, H. 1
PO Sox 770724 i'i '9'."''w'•'( ....
Eagle fttwr, Alaska 99577 -
9O7.694.702B
GEOTECHNICAL DOW'
6/10/11 r
EPIRAI
MUNICIPALITY OF ANCHORAGE
Development Services Department ` Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 050-312-13
Certificate of On -Site Systems Approval
Expiration Date: _1(-7-19
1. GENERAL INFORMATION
Complete legal description Highland Terrace, Lot 6
Location (site address) 19355 High Bluff Drive, Eagle River, AK
Current property owner(s) Peter HeWkO Day phone 907-691-5688
Mailing address 11935 Broadwater Dr, Eagle River, AK 99577
Real estate agent Day phone
2. TYPE OF DWELLING:
El Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic
0
Water Storage
❑
Holding Tank=
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 515D
Date of Payment V/ G Q
Receipt Number d0LI690
COSA# 05Cl9135q
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site_to verify the information submitted.
Name of Firm Forge Engineering Phone 907-522-7773
Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503
Engineer's Printed Name Michael E. Anderson, P.E. Date 7/31/19
6. DSD SIGNATURE
4— System #1 Approved for �' bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms, with the following stipulations:
ITY<<r(�(6i
Com%
WqTSITE c
SrF� p
-- m
ter' p�
GRAM
r�
GRA
•J M �o
)110
By: i �'`' Original Certificate Date: 17—
The
—
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Highland Terrace, Lot 6
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 7/1/13
Total depth 400 ft
Cased to 44 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 26 in.
Date of flow test for COSA 7/24/19
Static water level at beginning of test 17 ft.
Comments
B. TANK DATA
Age of tank(s) 5 years
Tank type/material Septic/Plastic
Measured operating fluid level in septic tank 55
❑ Standpipes/foundation cleanout per record drawing
Date of pumping 7/30/19 - JRs Pumping
D. ABSORPTION FIELD DATA Deep Trench
Which system tested (date installed) 1/7/14
❑ ALL standpipes present per record drawing
Total measured depth from grade 9.9 ft (max)
Measured depth to pipe invert from grade 3.7 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced 2,030 gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 050-312-13
Structure served by this system
Well production at time of test 5.4 gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes ❑ No
❑ Coliform bacteria is Negative
Nitrate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by Forge Engineering
Date of Sample 7/23/19
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments: N/A
Adequacy test date 7/24/19
Results ❑✓ Pass For 4 bedrooms
Fluid depth prior to test 26.5 in
Water added 1,169 gal
New depth 54 in
Elapsed time 1200 min
Final fluid depth 24 in
Absorption rate '600 gpd
Any rejuvenation treatment (past 12 months) No
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
0 Yes
if No
Community Sewer Manhole/Cleanout > 100'
✓Q Yes
if No
ft
r7,/ Yes
if No
Neighboring Tank > 100' F/� Yes
if No
ft
Private Sewer/Septic Line > 25' 0 Yes
if No
Absorption Field on Lot > 100' M Yes
if No
ft
Holding Tank > 100' F,71 Yes
if No
Neighboring Absorption Fields > 100'
Yes
if No
Animal Containment > 50' 0 Yes
if No
7 Yes
if No
ft
if No
ft
F. ENGINEER'S COMMENTS
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' F/� Yes
if No
ft
21 Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' F-/� Yes if No ft Surface Water > 100'
ft
ft
ft
ft
ft
F Yes if No ft
Property Line > 5'
0 Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
El Yes
if No
ft
Private Wells > 100' Fv Yes if No _
Water Main > 10'
0 Yes
if No
ft
Community Wells > 200' 0✓ Yes if No_
Water Service Line > 10'
F✓ Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
E]
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
✓�
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
0
Yes
if No
ft
Private Wells > 100' Yes if No
Water Service Line > 10'
Q✓
Yes
if No
ft
Community Wells > 200' ❑✓ Yes if No
Surface Water > 100'
✓�
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
certify that l have determined through field inspections and review '�;;:•" °i.,
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date."`s` 49th
MICHAEL E. ANDERSON
No CE -4381
7/31/19 .*•°°Ct�r
COSA Checklist yellow sheet •...,"'°"°°Y,
f'VESSySt®.
ft
ft
ft
ft
T/1 I'0=PI1jLda; ussaw�yI=lolaafoad�xoqu!/t/o/n/I!Lw/woo•a13oo2•lieuT//:sduq
-51
t ISE � ;�` _`"' •r'� !
' P p \
IN
tion ot the Structure('s
8�00 n n this mord dr,a r
$hilt a?l EES
i I Sl thT'
By; i� �
ASSUILi
SUTARD & ASSOCIATES LAI\TD SURVEYING 694--0829
1 HEREBY CEwniry THAT I HAVE SURVEY€`L) THERAT�L
SCALE.�
FOLLOWING DESCRIBED PROPERTY: OF A
AND THAT €it6 EI�CR6ACH 6,V-"S, E)CIST iD(CEP1 A» � �� • •ter x
INDICATED.
IT IS THE RESPONSIBILITY OF THE
OWNER is RETE i�iEk tE Ti f EXISTENCE (P EKY d K Y ,
4- W
EASEMEf� TS, COVENANTS.. CR RESTRICTIONS
GREP�' � y s
WHICH DO NOT A FE R 0�� THE RECv^i�Dt� Si1Si7E-
VISION PLAY". UNDER No CIRCUNESTANCES SE�iULb 'EB
ANY DATA HEREON BE USED �'oR COEtit ai1�UCTEC}i� %x?� i� �? �� J LS 5 ,? z,
OFFENCE LIMES; Cts FOR ES`�AE3LI rf-1IEt(G 80UI�ED- —D
ARY LINES. RAWN, h,
A'i�uo-•.+dm.d...,.....�.�,�,�m...wrw,�sz., ..w,..;�.�ar..maa�-..�
2df• I00 jpngsL-llnlq-g2iq
6l OZ/6i/L
• Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 0-50-5J2-1-3
1. GENERAL INFORMATION
Expiration Date: .2 - � /_�-
Complete legal description F4_10IL-Ii D `ter L'.
Location (site address) 1"%35C, iiSff130,iFF' L>r'?
Current Property owner(s) Day phone _3 r1;; -ye?v
Mailing address
Real Estate Agent
'3G -
.5i l3OF K r i 1� f}n/LNORA . A K f /,W)l
2. TYPE OF DWELLING:.
[�J' Single Family (w/wo ADU)
❑ Duplex
❑ Multiple. Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public M1 f, System
❑
Public Sewer
❑
WaiverNariancerequestfor: 5LoPE (>Z� T�r,2 �r-rI}N Zr5°'a Distance: "
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date:
COSA Fee $ 6' 'AD Waiver Fee $ _
Date of Payment Ct 2�l y C Date of Payment
Receipt Number Receipt Number
COS A# O aCAWi Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below; I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal add State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Phone
Address
Engineer's Printed Name BI t;L-11kO Date
OFAt
6. DSD SIGNATUREi�'° t`d,
System #1 Approved for bedrooms •* �// u
a!_ l rt�yFi i;
System #2 Approved for _bedrooms � • , � • � r,
Disapprovedj
_a,rNO.t..l..,t:...r
Conditional approval for bedrooms, with the following �4+' jpions: o
i r hi41";iiC;•;f ;i; ::
jTi...... u.
OF
MTC
:g WATER AND
BY7 �ii/ / Original Certificate Date:_ 3
Th " uni pal7t of Drage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSH) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet ( - : c
6
If more than 1 septic system is on the lot:
. COSA Checklist # 1 of 2 .
Structure served by this system =
Certificate of On -Site Systems Approval Checklist
Legal Description: 41-6141 410n 71Z rM irk t.QTti Parcel ID: 050
A. WELL DATA
Well type T171 V If A, B, or C provide PWSID # Well Log (Y/N)
Date completed Sanitary seal (YIN) Wires properly protected (Y/N) Y _
Total depth �_ft. Cased to Casing height (above ground) ? `t . in.
FROM WELL LOG AT INSPECTION
Date of test -1-23
Static water level q'2- ft. ft.
Well production 5 g,p.m, g.p.m.
WATER SAMPLE RESULTS:
Coliform A59Wcolonies/100 mL Nitrate V,: %% mg/L
Arsenic 0433 ug/L Date of sample: &t Collected by: -fes !' PFwkO
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material F7LVE7NV/ ENE Date installed 7--7 -2 q
Tank size -1250 . gal. Number of Compartments z Cieanouts (Y/N)
Foundation cleanout (YIN) rlonroccinn nvcr tanL NlAll w H1g t I (Y'N) Al
( ) �_ �r ���.� - -rte. • k •i i h wa er a arm ,
Date of pumping IVA -niBti Pumper
C. ABSORPTION FIELD DATA
Date installed rating (g.p.d./ftZ or ftZ/bdrm) -1,i System type TC6NCH
Length k 2 ft. Width a ft. Gravel below pipe 6 ft
Total depth 2 W ft. Eff. absorption area 200 ftZ Monitoring tube r Depression over field N
Date of adequacy test ryR-1v6i✓ Results (Pass/Fail) For H bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Date installed 1v,4 - NONE Size in gallons Manhole/Access (YIN)
"Pump on" level at in. "Pump off" level at in. High water alarm level at' in.
Datum
Cycles tested
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot 10D*
Absorption field on lot 100'r
Public sewer main SVA
Meets alarm & circuit requirements?
On adjacent lots VO It
On adjacent lotsO t
Public sewer manhole/cleanout N'A
Sewer /septic service line -100 1" Holding tank VQ
Animal containment areas 49-106-t- Manurelanimal excrete storage areas
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 51 Property line 5-r Absorption field S t
Water main A'A Water service line 0* 10- . Surface water 10a -f'
Wells on adjacent lots 100 t
ABSORPTION FIELD ON LOT TO:
Property line 10 t Building foundation 10f Water main IV14
Water Service line Aft Surface water 100 4, Driveway, parking/vehicle storage 50
Curtain drain SOY. Wells on adjacent lots j0Q
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that t have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name tPl� Ht;Wkt?
Date %-20 -1't
COSA brown sheet 10-10-12.doc
• 49TH
sE•^ PETERDAVI :Eda q
tffB F n cosy .n 4
,9z