HomeMy WebLinkAboutEND OF THE ROAD LT 3End of the P-oad Lot 3 #041-033-25 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 7 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP-141343 PID Number: 041-033-25 Dwelling: X Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: H New ❑ Upgrade Name: Susan Kruse ABSORPTION FIELD X Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 10400 Blackwolf Cr., Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-337-4165 5 1.2 GPD/SF 9.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4,7 Ft. Gravel depthbeneathpipe 5.1 Ft. Subdivision Block Lot End of the Road, Lot 3 Fill added above original grade 0 Ft. Gravel length 68 Ft. Township Range Section 12N 2W 6 Gravel width 3 Ft. Beds: Number of Lines 1 Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 693 Ftp 1 0 Ft. Well 140' 170' >100' >100' 76' TANK ®Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity I 1500 Gal. Surface Water 100'+ 100'+ >100' >100' Material Number of compartments Lot Line 60'+/- 46'+/- >100' >100' STEEL 2 Foundation 35' 56' >100' >100' LIFT STATION Manufacturer Capacity Curtain Drain >100' >100' I >100' >100' I Gal. Remarks Ground surface graded to drain and Pump on level at r . Pump off lev in. High water alarm at in. stabilized. Seeding will be completed in spring Of 2016. Pump make odel Electrical Inspections performed by `There are no known lift stations, holding tanks, or curtain drains. Installer PIPE MATERIAL House to tank PVC -133034 Tankto PVC -D3034 drainfeld GLW Enterprises Drainfield PVC -133034 CO/MT PVC -133034 Inspector Dee High BENCHMARK (Assumed elevation) 1275.77 ft Insp10 9/8/14 9/10/14 Co- cation and description dates: 2nd 3'o 9/12/14 4" 10/28/15 FINISH FLOOR GARAGE COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp ♦wlil % ♦�F, OFA4 ��� Conditional Approval: Date i P,.•''••••'••qS �� %.. .. ..... 00! , �♦0 '0 NNIS EE H; v f / CE 5807 �; 'SAr Approved t tm. Date Inspection Report-9-1-12.doc Permit No OSP-141343 Legal Description: Municipality of Anchorage Page 2 of 7 Development Services Department Date 11/23/15 BUILDING SAFETY DIVISION P.O. Bog 196650 • Anchorage, AK 99519-6650 • Tel: 343-7904 Well & On—Site Wastewater Disposal System LOT 3, END OF ROAD SUBDIVISION Parcel ID No. 04103325 NOTES 1. ALL CONSTRUCTION WAS COMPLETED IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS OF THE MUNICIPAL CODE. 2. CONTRACTOR INSTALLED 1500 GAL, TWO COMPARTMENT, STEEL SEPTIC TANK. 3. ALL PIPE IS PVC CONFORMING TO ASTM D3O34. 4. LOT 3, END OF THE ROAD IS BORDERED ON THE NORTH BY A PUBLIC ROAD, (BLACKWOLF CIRCLE), ON THE EAST BY A 12.7 ACRE LOT WITH A SINGLE FAMILY HOUSE; ON THE SOUTH BY CHUGIAK STATE PARK; AND ON THE WEST BY AN UNDEVELOPED RESIDENTIAL LOT (4.6 ACRES). 5. LOT 3, END OF THE ROAD HAS A 6" RESIDENTIAL WELL DRILLED TO A DEPTH OF 247 FEET. THE WELL IS REPORTED TO PRODUCE 3 GPM. 6. THERE ARE NO EXISTING SPETIC SYSTEMS WITHIN 200 FEET OF THE PROPERTY LINE. THE PROPOSED SYSTEM WILL NOT ADVERSELY IMPACT THE ADJACENT PROPERTIES. 7. THERE ARE NO STREAM, PONDS OR OTHER WATER BODIES ON OR WITH 150' OF THIS LOT OR SEPTIC SYSTEM DRAWMG .... Fa! �P ••. .•• ,;�9 TH ;DENNIS DE IGF{, ♦ ♦�9••• CE 58 •:.� Profes500o�� DATE 1 � � IL W.O. 101038 C. FILE 1O38CSPlR Permit No.OSP-141343 Page 3 of 7 Municipality of Anchorage W.O. 131038 Development Services Department Date 11/23/15 BUILDING SAFETY DIVISION P.O. Bog 196650 • Anchorage, AK 99519-6650 • Tel: 343-7904 Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS = 5 2. USE DEEP TRENCH SYSTEM PID No. 04103325 3. REQUIRED ABSORBTION AREA = (# BEDROOMS)(150 GPD/BR) TRENCH APPLICATION RATE (5)(150) = 625 SF 1.2* 4. ACTUAL ABSORPTION AREA, TRENCH LENGTH= ABSORPTION AREA/(2 X DEPTH OF GRAVEL) DEPTH OF GRAVEL = 5.0' INSTALLED 5_1' QA LENGTH OF TRENCH = 62.5 L.F. INSTALLED 68 L.F. Q ACTUAL ABSORBTION AREA = 693 S.F.QA PERCOLATION RATE PIT & TRENCH APPLICATION RATE MOUND & BED APPLICATION RATE MIN/INCH GPD/SF GPD/SF 0-1 NOT SUITABLE NOT SUITABLE * 1-5 1.2 0.8 6-15 0.8 0.5 16-30 0.6 0.4 31-60 0.45 0.3 GREATER THAN 60 NOT SUITABLE NOT SUITABLE FILTER LAYER 1.0 .7 I.-.. A 12 11 MOA . F Rx 10.Y N Permit No.OSP-141343 Page 4 of 7 Municipality of Anchorage W.O. 131038 Development Services Department Date 11/23/15 BUILDING SAFETY DIVISION P.O. Box 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION PID No. 04103325 N LOT 2 12.7 Ac DRIVEWAY \\ \� EXISTINGNW RAVEL LOT 3 F+ ' 3.57 AC.CR \ \ 94 100PROTECTIVE — I-0, w \ \ PQ WELL RADIUS a \ \ O LOT 4 �7 4.6 Aco / \ \ 124 bu)� \ \ PROPOSED SEPTIC \ \ \ SYSTEM TH#2 \THJ1 144.L N89'58'30"E 412.00 lftgi_ 1 � t ; CHUGACH STATE PARK SM PLkN - OVIM YIR* SCAM 1 = LOW ]2-01] A (2/91) MW W G i 10J0 m CURVE TABLE CURVEI RADIUS I LENGTH CENTRAL ANGLE TANGENT CHORD CHORD BEAR. C71 50.00 109.12 125'02 49 96.15 88.72 S 34'22 09 W C74 1 50.00 1229.35 1 262'49'09" 1 75.00 IS 09'45'11" E C76 1165.54 1282.75 1 97'51 48 189.97 1249.61 IN 67'29 00 W ]2-01] A (2/91) MW W G i 10J0 m Permit No OSP-141343 Legal Description: Municipality of Anchorage Development Services Department BUILDING SAFETY DIVISION Page 5 of 7 W.O. 131038 Date 11/23/15 P.O. Box 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 Well & On—Site Wastewater Disposal System LOT 3, END OF THE ROAD PID No. 04103325 I ®WELL N LOT 3 30' TEST 11 3.57 AC. HOLE RADIUS i SCALE: 1" = 30' / \ INSTALLED / FOUNDATION / CLEAN OUT / � TH#2 \1 / I� C.O. O I \ \ O M.T. O \ 1 PLACED 2 LAYERS OF 2" INSULATION OVER / \ PIPE (60 PSI) WIDTH=4' / p O 100' PROTECTIVE C.O.'S WELL RADIUS �w O o O� C.O.'S � INSTALLED 1500 GAL, O M.T. 2 COMPARTMENT w w TH#1 C O SEPTIC TANK WITH (if4" OF INSULATION LU U} \ / -ov m j N89'58'30"E 412.00 _ _ CORD DRAWDiG CHUGACH STATE PARKAr • F, �FqG �� P�,.........qs PROPOSED SITE PLAN':.'*L SCALE: 1"=30' 0. 0 ..............0.0..., Permit No. OSP-141343 Page 6 of 7 Municipality of Anchorage W.O. 131038 Development Services Department Date 11/23/15 BUILDING SAFETY DIVISION P.O. Box 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION PID No. 04103325 28' 7 f 15' 34' 34' HOUSE C.O.'S C.O. M.T. a FUTURE FINISH GRADE 1268.51 INSTALLED FOUNDATION 2 C.O. ORIGINAL GROUND/ FINISHED GRADE PLACED 4" INSULATION --__4t PLACED 4" 09 INSULATION PVC M T. CLEAN OUT DRAIN 7 END OF FROM 1271.3 1266.2 TRENCH HOUSE 1266.1 0.0% SEPT. TAN 1500 GAL 4" PVC PIPE 1263.8 1263.8 4" PERF. PVC PIPE *ALL ELEVATIONS ARE TO INVERT OF PIPE UNLESS OTHERWISE NOTED PROFILEOF NJ TRENCH M SCALE: NTS RECORD DRAWING OF AtqS*� Ar `?:49TH yt; 0(. .... ...s........0 ...� ........ ..•.......0 ♦ _)P,3;DENNIS E HIGH' ��� �•.� CE 5807 '4,' iof s6c& w u�i DATE Permit No. OSP-141343 Page 7 of 7 Municipality of Anchorage W.O. 131038 Development Services Department Date 11/23/15 BUILDING SAFETY DIVISION P.O. Box 196650 • Anchorage, AK 99519-6650 • Tel: 343-7904 Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION PID No. 04103325 ORIGINAL GRADE TH#1 r, --FINISH GRADE— ORGANIC/OVER BURDEN (PT) I 1.5' N INSTALL 2 LAYER OF 2" INSULATION FROM HOUSE TO TANK (60 PSI) GEOTEXTILE FABRIC SILTY SANDY GRAVEL 12% SILT (GP) 0Ug4" PERFORATED PIPE SEE NOTE 3, SHEET 2 5 di SEPTIC ROCK PER M.O.A. SPECIFICATIONS SLIGHTLY SILTY 10.0' SANDY GRAVEL (GP) Z r:. TO � WA 16' B.O.T. RECORD DRAWING �..., TO BEDROCK OR IMPERMEABLE LAYER cF, � ... 'd k. SCALE-- NM 103BCSP5R W.O.# 131038 DHI CONSULTING ENGINEERS 800 E. DIMOND BLVD. SUITE 3-545 ANCHORAGE, ALASKA 99515 SOILS LOG -PERCOLATION TEST TEST HOLE LOG #2 *'*�%vk\ 4P 01 OFAt � • ..�...0 ;DENNI DE I H; �& 9• l CAr PERFORMED FOR: SUSAN KRUSE DATE PERFORMED: 9/8/14 �I;�erP.,C::•.:,.'= LEGAL DESCRIPTION: LOT 3, END OF THE ROAD SUBDIVISION 44 °�'rofess+ol`O�� 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TH #2 ORGANIC/OVER BURDEN (PT) SLIGHTLY SILTY SAND GRAVEL (GP) B.O.H. SLOPE Dote: _9/10/14 SITE PLAN WAS GROUND WATER S ENCOUNTERED ? NO L 0 IF YES, AT WHAT P DEPTH ? E #449 DEPTH OF WATER AFTER MONITORING ? NONE DATE: _ 8/1/13 READING DATE GROW TME NET TME DEPTH NET DROP PERG RATE 1. 9/8/14 7:45 MIN 6. 6. 1.29 2. 9/8/14 7:48 MIN 6. 6' 1.30 3. 9/8/14 7:47 MIN 6" 6' 1.30 PERCOLATION RATE: 1.30 (MINUTES/INCH.) PERCHOLE DIAMETER: 6.. TEST RUN BETWEEN: 3.0 FT. AND 3.5 FT. COMMENTS: THE SOILS WERE PRE-SOAKED PRIOR TO STARTING THE PERCOLATION TEST. PERFORMED BY: DHI CONSULTING ENGINEERS. I DEE HIGH CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 09/08/14 1038CSS1D M -w arguing, rte. OP -0. Box 110389*Anghorage, AK 99811• •907-345-4000 • 907-345-3287 Foxe Job No. 14-127 Well Owner. Hall, Hobert KnW, Susan Ube of WWI: Domestic Iegal DOWPtlant End of the ftoid Lot moots Dr1N Metho& Air rota Hft Dapft 247' OeaingSim- 8' Ceeadto 1 74• Mauft 87 AB Vale Well OwVWtlon: OPsnend X Brien - - Patfmated Method SwwVPirforition deco *don — -- QmM laxse: ( ) SaCWA) or Banton gran Wen Oeieelopntent r and water well DkWdittocL YMOM= meach ftcltsitat 3 GPMror 14 afdmwdown NNlhed: SubmerolerLaim 1-0D' StaRDatx —� nt)ii-M !DOW _9!4134 Tan PMP Deft9/ /" F#ql PumphnNNN Deix . ..evelopment Services Departmel, Building Safety Division On -Site Water & Wastewater Program M! 4700 Elmore Road P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor www.muni oro/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP141343 Date of Issue: 08/27/14 Parcel Identification Number: 041-033-25 Legal Descrip End of the Road Lt 3 Pump Installation Date: 9/16/14 Pump Intake Depth Below Top of Well Casing: 234.3 feet Pump Manufacturer's Name: Goulds Pump Model:105BO5411 Pump Size .5 hp Pitless Adapter Burial Depth: 13.3 feet Pitless Adapter Manufacturer's Name: MAASS Pitless Adapter Installer: MW Drilling, Inc. Well Disinfected Upon Completion? R] YesEl No Method of Disinfection: Bleach Comments: Pump Installer Name: MW Drilling, Inc. rroperty Owner Name & Address: Robert Hall & Susan Kruse 9875 Middle Rock Road Anchorage AK 99507 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. EXISTING GRAVEL DRIVEWAY \ \ " / '//\-15' T&E \ \ \ / ESM'T \ 5' SNOW ESM'T LOT 3 \ \ LEGEND SYMBOL DESCRIPTION CUM TAM BOUNDARY LINE CURVE -- -" ADJACENT PROPERTY LINES -- CENTERLINE OF R.O.W. ------- EASEMENT LINES T & E TELECOMMUNICATIONS S 34'22 T9W & ELECTRICAL F 3.57 AC. GRAVEL DRIVE- \ \ 0 ' WAY UNDER y \ CONSTRUCTION \ \ Q ' 100' PROTECTIVE � W WELL RADIUS a LOT 4 4.6 Ac STEEL WELL z M k, CASING \ ' o \ I FOUNDATION / 0' \ \ CLEANOUT / o \ \ 'R \`/ UN y E \ �� \ /%` FOUNDATION -HOUSE UNDER CONSTRUCTION _ ABSORPTION SEE DET. 1 SHT 2 - FIELD � LOT 2 _ N89'58'30"E 412.00 CHUGACH STATE PARK MONITORING - TUBE -2 TYP 1 -WELL \ CLER _ OUT T•1.yho : (07p"-1306 r x (9071000-1383 MS R. Da1Wa - e7Ri s"M% ANCOMILM AtAM MHS 131038 FUMY. rat 1038CSPiSIsCALE 1"=100' JDATE 11/20/15 2143 F.B: • "STE cASEL WELLN NOTES 1. THE PROPERTY BOUNDARY IS SHOWN PER THE PLAT OF "END OF THE ROAD" SUBDIVISION. PLAT NO. 2010-39 2. DRIVEWAY, PARKING PAD AND HOUSE ARE UNDER CONSTRUCTION AT THE TIME OF THIS SURVEY. FA VE WELL PRAADTIUS � I i & OF AZ,q DEE("GH J/ i• •. LS -968 � r DATE arm++++11/24/5 CERTIFICATION L Dee High. a Registered Professional Land Surveyor, do hereby eertify that a survey of the property described hereon hu been performed by me or under my direct the thus of h1 that existing improvements visible at Murray are shown hereon. It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions. Under no circumstances should any data hereon be used for construction or for establishing fence or boundary lines. LOT 3, END OF ROAD AS -BUILT SURVEY 2015 SWING = CUM TAM NO CURVE RADIUS LENGTH 1 CENTRAL ANGLE ITANGENTI CHORD CHORD BEAR. C1 50.00 109.12 125'02 49 96.15 88.72 S 34'22 T9W C2 50.00 1229.35 1 26249'09" 1 1 75.001S 09'45'11 E C3 165.54 1 282.75 1 97'51'48- 189.97 1249.61 IN 67'29 W' MONITORING - TUBE -2 TYP 1 -WELL \ CLER _ OUT T•1.yho : (07p"-1306 r x (9071000-1383 MS R. Da1Wa - e7Ri s"M% ANCOMILM AtAM MHS 131038 FUMY. rat 1038CSPiSIsCALE 1"=100' JDATE 11/20/15 2143 F.B: • "STE cASEL WELLN NOTES 1. THE PROPERTY BOUNDARY IS SHOWN PER THE PLAT OF "END OF THE ROAD" SUBDIVISION. PLAT NO. 2010-39 2. DRIVEWAY, PARKING PAD AND HOUSE ARE UNDER CONSTRUCTION AT THE TIME OF THIS SURVEY. FA VE WELL PRAADTIUS � I i & OF AZ,q DEE("GH J/ i• •. LS -968 � r DATE arm++++11/24/5 CERTIFICATION L Dee High. a Registered Professional Land Surveyor, do hereby eertify that a survey of the property described hereon hu been performed by me or under my direct the thus of h1 that existing improvements visible at Murray are shown hereon. It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions. Under no circumstances should any data hereon be used for construction or for establishing fence or boundary lines. LOT 3, END OF ROAD AS -BUILT SURVEY 2015 SWING = TABLE NO A B C DESCRIPTION 1 144.1 92.9 CLEANOUT 2 148.2 94.9 MONITURING TUBE 3 46.6 50.1 AN 4 109.0 29:1 NXr- 5 32.9 67.9aCLEANOUT6 36.3 69.47 44:0 73:68 47.9 75.89 53:1 79.110 56.6 80:411 MONITORING - TUBE -2 TYP 1 -WELL \ CLER _ OUT T•1.yho : (07p"-1306 r x (9071000-1383 MS R. Da1Wa - e7Ri s"M% ANCOMILM AtAM MHS 131038 FUMY. rat 1038CSPiSIsCALE 1"=100' JDATE 11/20/15 2143 F.B: • "STE cASEL WELLN NOTES 1. THE PROPERTY BOUNDARY IS SHOWN PER THE PLAT OF "END OF THE ROAD" SUBDIVISION. PLAT NO. 2010-39 2. DRIVEWAY, PARKING PAD AND HOUSE ARE UNDER CONSTRUCTION AT THE TIME OF THIS SURVEY. FA VE WELL PRAADTIUS � I i & OF AZ,q DEE("GH J/ i• •. LS -968 � r DATE arm++++11/24/5 CERTIFICATION L Dee High. a Registered Professional Land Surveyor, do hereby eertify that a survey of the property described hereon hu been performed by me or under my direct the thus of h1 that existing improvements visible at Murray are shown hereon. It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions. Under no circumstances should any data hereon be used for construction or for establishing fence or boundary lines. LOT 3, END OF ROAD AS -BUILT SURVEY 2015 On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141343 Tax Code Number: 04103325000 Work Type: WellSeptic Renewal Permit Effective Dates: August 27, 2014 Design Engineer: DEE HIGH Subdivision: END OF THE ROAD to August 27, 2015 Site Legal Address: END OF THE ROAD LT 3 G:2143 Owner/Address: HALL ROBERT J & KRUSE SUSAN L 9875 MIDDLE ROCK ROAD ANCHORAGE AK 995071287 Site Mailing Address: 10400 BLACKWOLF CIR, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Lot Size in Sq Ft: 155602 Total Bedrooms: 5 Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By: MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcell.D. 041-033-25 Property owner(s) Susan Kruse Day phone 907-344-1385 Mailing address c/o Dee High 800 E Dimond Blvd. Ste. 3-640, Anchorage, AK 99515 Site address Legal description (Sub'd., Block & Lot) Lot 3, End of the Road Subdivision Legal description (Township, Range & Section) Lot Size 155509 Sq. Ft. APPLICATION IS FOR: (® all that apply) Absorption Field 19 Septic Tank IN Holding Tank ❑ Privy ❑ Private Well 0 Water Storage ❑ Number of Bedrooms 5 APPLICATION IS AN: TYPE OF DWELLING: Initial =EiL_ Single Family (SF) ❑X (w/wo ADU) Upgrade ❑ Duplex (D) ❑ Renewal Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. authorized agent) Permit/Rush Fees: AE�F_ Waiver Fees: Date of Payment: Receipt Number: Permit No. ose 1413 5(3 Permit App_-'-: - ::...:c: Date of Payment: Receipt Number: Waiver No. On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131247 Tax Code Number: 04103325000 Work Type: WellSeptic Permit Effective Dates: August 20, 2013 to August 20, 2014 Design Engineer: DHI CONSULTING ENGINEERS Subdivision: END OF THE ROAD Site Legal Address: END OF THE ROAD LT 3 G:2143 Owner/Address: HALL ROBERT J & KRUSE SUSAN L 9875 MIDDLE ROCK ROAD ANCHORAGE AK 995071287 Lot Size in Sq Ft: 155602 Site Mailing Address: Total Bedrooms: 'A" S This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By MUNICIPALITY OF Community Development Department Development Services Division (O*D On -Site Water & Wastewater Program ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Paroel I.D.— Property owner(s) SusA L,� FLuuse_ Day phone _ J° t - k las Mailing address % �,� Arlo L Site address„ Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) L,ur I EHdmGe„sci rule/ Lot Size y. to Re Sq. Ft. Number of Bedrooms yL 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (0 all that apply) Absorption Field 21� Initial Single Family (SF) Septic Tank Upgrade ❑ (w/wo ADU) Holding Tank ❑ Renewal ❑ Duplex (D)_ ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well y(� Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. or authorized Permit/Rush Fees: I?& Date of Payment: 2W8 Receipt Number: 016-233' Permit No. 05 IP 131A1 Permit App_9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit No. OSP-131247 Go Page 1 of 7 Municipality of Anchorage 9 Development Services Department Date 6/18/14 BUILDING SAFETY DIVISION P.O. Boa 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 Proposed Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF ROAD SUBDIVISION Parcel ID No. 4103325 SITE NARRATIVE LOT 3, END OF THE ROAD IS BORDERED ON THE NORTH BY A ROAD, (BLACKWOLF CIRCLE), ON THE EAST BY A 12.7 ACRE LOT WITH A SINGLE FAMILY HOUSE; ON THE SOUTH BY CHUGIAK STATE PARK; AND ON THE WEST BY AN UNDEVELOPED RESIDENTIAL LOT (4.6 ACRES). LOT 3 IS BEING DEVELOPED WITH A FFIVE (5) BEDROOM SINGLE FAMILY HOME. WELLS: THE DEVELOPMENT CALLS FOR ONE, 6" RESIDENTIAL WELL. WELLS IN THE AREA HAVE BEEN FINDING WATER AT ABOUT 150 FEET. BASED ON THE PAST RESULT WE EXPECT THE WELL TO PRODUCE IN EXCESS OF 5 GPM. THE ONLY LOT THAT HAS BEEN DEVELOPED HAS A WELL WHICH SETS MORE THAN 200 FEET EAST OF THIS BOUNDARY. IT PRODUCES ABOUT 15 GPM. A WELL ON THIS LOT IS NOT EXPECTED TO IMPACT EXISTING OR FUTURE WELLS. SEPTIC SYSTEMS: THERE ARE NO EXISTING SPETIC SYSTEMS WITHIN 200 FEET OF THE PROPERTY LINE. THE PROPOSED SYSTEM WILL NOT ADVERSELY IMPACT ANY OF THE ADJACENT PROPERTIES. DRAINAGE: THERE ARE NO STREAM, PONDS OR OTHER WATER BODIES ON OR WITH 150' OF THIS LOT OR SEPTIC SYSTEM. OFq�q��� gyp••. .• �s�� �# Ar TH %. 600660 6... 00090 .000008 goo* 6.0 .DENNIS D E HIG f •.o CE 5807 a •••......•••\ 4& Vg DATE V%k -ib- W.O. 101038 C. FILE 1038CSP1D SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS = 5 2. USE DEEP TRENCH SYSTEM 3. ABSORBTION AREA = (# BEDROOMS)(150 GPD/BR) TRENCH APPLICATION RATE (5)(150) = 625 SF 1.2* 4. TRENCH LENGTH= ABSORPTION AREA/(2 X DEPTH OF GRAVEL) IF DEPTH OF GRAVEL = 5' THEN LENGTH OF TRENCH = 62.5 L.F. PERCOLATION RATE PIT & TRENCH MOUND & BED APPLICATION RATE APPLICATION RATE MIN/INCH GPD/SF GPD/SF Permit No.OSP-131247 NOT SUITABLE Page 2 of 7 1.2 Municipality of Anchorage W.O. 131038 0.5 Development Services Department Date 6/18/14 31-60 BUILDING SAFETY DIVISION 0.3 GREATER THAN 60 P.O. Bog 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 NOT SUITABLE Proposed Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION PID No. 4103325 SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS = 5 2. USE DEEP TRENCH SYSTEM 3. ABSORBTION AREA = (# BEDROOMS)(150 GPD/BR) TRENCH APPLICATION RATE (5)(150) = 625 SF 1.2* 4. TRENCH LENGTH= ABSORPTION AREA/(2 X DEPTH OF GRAVEL) IF DEPTH OF GRAVEL = 5' THEN LENGTH OF TRENCH = 62.5 L.F. PERCOLATION RATE PIT & TRENCH MOUND & BED APPLICATION RATE APPLICATION RATE MIN/INCH GPD/SF GPD/SF 0-1 NOT SUITABLE NOT SUITABLE * 1-5 1.2 0.8 6-15 0.8 0.5 16-30 0.6 0.4 31-60 0.45 0.3 GREATER THAN 60 NOT SUITABLE NOT SUITABLE FILTER LAYER 1.0 .7 M-011 A (2/2) " 0 6 A 101l0�0 Permit No. OSP-131247 CO # Page 3 of 7 Municipality of Anchorage W.O. 131038 Development Services Department Date 6/18/14 BUILDING SAFETY DIVISION P.O. Box 196650• Anchorage, AK 99519-6650• Tel: 343-7904 Proposed Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION PID No. 4103325 EXISTING GRAVEL -_' `'DRIVEWAY -Uj� !� TABLE CURVE RADIUS LENGTH CENTRAL ANGLE TANGENT CHORD CHORD BEAR. 1 50.00 109.12 125'02 49 96.15 88.72 15 34-22-09-' W C74 1 50.00 1229.35 U� 1 1 75.00 IS 09'45'11" E C76 1165.54 p ; 1282.75 1 97'51 48 fN. 0 4a EL .� OW LOT 4 W. 4.6 Ac #0 w W I I lnW � I rO 1 1 f 1� \ f 1 iii \i o I 8llE PUN — 0M TM SCIi V = low N89'58' 0"E 412.-00 _ CHUGACH STATE PARK PER OF A�qS Ar TH • ;DENNIS DFWP113Ft*g �'••. CE 7 .".Cri 'SXPi` ' ., p AV � •�••......••� . DATE 12-03 A 02/111) MM 0 F ills 1W z !� TABLE CURVE RADIUS LENGTH CENTRAL ANGLE TANGENT CHORD CHORD BEAR. 071 50.00 109.12 125'02 49 96.15 88.72 15 34-22-09-' W C74 1 50.00 1229.35 1 262'49'09" 1 1 75.00 IS 09'45'11" E C76 1165.54 1282.75 1 97'51 48 189.97 1249.61 IN 67'29'00" W PER OF A�qS Ar TH • ;DENNIS DFWP113Ft*g �'••. CE 7 .".Cri 'SXPi` ' ., p AV � •�••......••� . DATE 12-03 A 02/111) MM 0 F ills 1W z Permit No OSP-131247 CO "tI Municipality of Anchorage Development Services Department BUILDING SAFETY DIVISION Page 4 of 7 W.O. 131038 Date 6/18/14 P.O. Boa 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 Proposed Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD PID No. I 1 LOT 3 -' 3.57 AC. 100' PROTECTIVE / \ WELL RADIUS' 4" MONITURING_ 4103325 PROPOSED N WELL SITE SCALE: 1" = 30' STALL 2 EA 4" CL UTS� / 30' TEST HQLE R IUB � INSTALL CLEAOU N \ M PLACE 2 LAYERS 6 INSULATION N PIPE (60 PSI) WIDTH= -AP ALL1500 a i SEPTIC TANK COMPARTMENT N ro CHUGACH 0 N 5 L.V. DEEP TRENCH PTIU SYSTEM STATE PARK PROPOSED SITE PLAN SCALE: 1"=30' C0-#/ Permit No. OSP-131247 Page 5 of 7 Municipality of Anchorage w.o. 131038 Development Services Department Date 6/18/14 BUILDING SAFETY DIVISION P.O. Boa 196650 • Anchorage, AK 99519-6650• Tel: 343-7904 Proposed Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION PID No. 4103325 34't 20' 1 62.5 HOUSE C.O.'S C.O. FINISH GRADE 1268.0 + - 2' ORIGINAL GROUND FOUNDATION C.O. 4" PERF. LACE 4" INSUL. PVC M.T. CLEAN OUT FROM HOUSE TO END OF 0 TANK -------,MIN TRENCH DRAIN 27 SLOPE o.og - FROM HOUSE EPT. TAN 4" PIPE 1500 GAL *ALL ELEVATIONS ARE TO INVERT OF PIPE UNLESS OTHERWISE NOTED M PROFILEOF TRENCH SCALE: NTS G ,&,Ws 1 OFA. ••0000.... S % AN 9 TH # % ... 000 . 0.0 0000 /...� 0000 .8...0 ;DENNIS DEE GOF •g�is CE 580 .' s • 44 der '•.......•'•� � DATE i[li•ITi 0191 Permit No. OSP-131247 CD-4�l Page 6 of 7 Municipality of Anchorage W.O. 131038 Development Services Department Date 6/18/14 BUILDING SAFETY DIVISION P.O. Box 196650 • Anchorage, AK 99519-6650 • Tel: 343-7904 Proposed Well & On—Site Wastewater Disposal System Legal Description: LOT 3, END OF THE ROAD SUBDIVISION M 1.5' 5' r, 16' ORGANIC/OVER BURDEN (PT) LO 4 SILTY SANDY GRAVEL 12% SILT (GP) SLIGHTLY SILTY 10.0' SANDY GRAVEL (GP) 0 LO TO BEDROCK OR IMPERMEABLE LAYER PID No. 4103325 AL GROUND YER OF 2" INSULATION TO TANK (60 PSI) )TEXTILE FABRIC " PERFORATED PIPE C ROCK PER M.O.A. SPECIFICATIONS 1038CSP50 Permit No. OSP-131247 DHI CONSULTING ENGINEERS Legal Description: LOT 3, END OF THE ROAD SUBDIVISION NOTES: c'0 '4-1 Page 7 of 7 W.O. 131038 Date 6/18/14 1 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS OF THE MUNICIPAL CODE, AND MOA STANDARD SPECIFICATIONS FOR STREETS, DRAINAGE, UTILITIES AND PARKS (MASS) 2009 AS CURRENTLY AMENDED, AND ALL APPLICABLE STATE AND FEDERAL REGULATIONS. 2 CONTRACTOR TO INSTALL 1500 GAL, TWO COMPARTMENT, STEEL SEPTIC TANK 3 SITE TOPOGRAPHIC SURVEY WAS PREPARED BY AERIAL TOPOGRAPHY EXISTING STRUCTURES, WELLS, SEPTIC SYSTEMS OBSERVED WITHIN 200 FT. OF THE PROPOSED SYSTEM SITE ARE SHOWN ON DESIGN DRAWINGS. 4 ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO ITS INCORPORATION INTO THE SYSTEM. 5 CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATERWAYS, SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. 5 CONTRACTOR TO STAKE PROPOSED SYSTEM & NOTIFY THE ENGINEER OF ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION. STAKE LOCATION OF EACH TRENCH END. NOTE DEPTH OF CUT ON LATH. CONTRACTOR SHALL HAVE SURVEY LEVEL AND ROD SET UP ON SITE DURING CONSTRUCTION. 6 CONTRACTOR TO NOTIFY THE ENGINEER AND DHHS 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF THREE SITE VISITS ARE REQUIRED. THE FIRST VISIT SHALL BE OF THE SUBGRADE PRIOR TO PLACING THE SEWER ROCK. THE SECOND VISIT SHALL BE AFTER THE PLACEMENT OF SEWER ROCK, DISTRIBUTION PIPING, STANDPIPES, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD VISIT SHALL BE AFTER THE WORK IS COMPLETED. 7 CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED -LINED, AS -BUILT DRAWINGS SHOWING ALL DATA AS SPECIFIED IN SEC. 15.65.F.2, 3, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN FIVE DAYS OF THE FINAL VISIT. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE AS-BUILTS SHALL BE USED BY THE ENGINEER TO PREPARE AND SUBMIT RECORD DRAWINGS TO DHHS. 8 ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN. 9 BOTTOM OF TRENCH EXCAVATION SHALL BE LEVEL. SIDEWALLS SHALL BE SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE, AND END OF TRENCH BOTTOM. 10 PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK. LEVEL ROCK SURFACE TO t 0.1' PRIOR TO INSTALLING THE PERFORATED PIPE. 11 ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034. ALL JOINTS SHALL BE SEALED WITH APPROVED GLUE. CLEANOUTS SHALL BE INSTALLED AT THE END(S) OF THE TRENCH(S). 4" MONITORING TUBE(S) SHALL BE INSTALLED AT THE END OF TRENCH, AS SHOWN ON PLANS. 12 COVER THE DISTRIBUTION PIPE WITH MIN 2" SEWER ROCK, BEFORE PLACING INSULATION AND/OR GEOTEXTILE, FILL, AND TOPSOIL. 13 MINIMUM SOIL COVER SHALL BE 4 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER, BUT THERE MUST BE A MINIMUM OF 2' OF SOIL COVER OVER THE INSULATION. ALL INSULATION BOARD SHALL BE 2" THICK POLYSTYRENE, DOW HI -35 OR ENGINEER -APPROVED EQUAL. CENTER BOARD WIDTH OVER PIPE. 14 AN APPROVED GEOTEXTILE FABRIC SHALL BE INSTALLED BETWEEN THE SEWER ROCK AND THE BACKFILL. 15 MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 16 SLOPE ALL FILL MATERIAL AND TOPSOIL TO DRAIN AWAY FROM IMPROVEMENT AT 2% MIN. SLOPE, AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD & WELL DOES NOT OCCUR. THE FILL SHALL BE LEFT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. THE TOP 4" OF COVER SHALL BE TOPSOIL. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MUNICIPAL SPECS. 17 CONTRACTOR TO BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF CONTAMINATED MATERIAL FROM THE EXISTING TRENCHS, IF ENCOUNTERED. n -M3 A (2/0) YW 0 G f 10.TL9lD 10 •i• W.O.# 131038��� \ \ \ DHI CONSULTING ENGINEERS ,�F, OFA � 800 EDIMOND BLVD. SUITE 3-545 i P•.'..*00-4.4 ANCHORAGE, ALASKA 99515 Ar�• SOILS LOG -PERCOLATION TEST TEST HOLE LOG #1 0:0.0000 ••• .6000. •00 O IS D HI PERFORMED FOR: SUSAN KRUSE DATE PERFORMED: 7/12/13 ,�4�1� •.� CE 5807 LEGAL DESCRIPTION: LOT 3, END OF THE ROAD SUBDIVISION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TOP EL=1268 ORGANIC/OVER BURDEN (PT) SILTY SANDY GRAVEL, 12% t SILT (GP) SLIGHTLY SILTY SAND GRAVEL (GP) B.O.H. EL=1252 SLOPE SITE PLAN WAS GROUND WATER S ENCOUNTERED ? NO L 0 IF YES, AT WHAT P DEPTH ? E DEPTH OF WATER AFTER MONITORING ? NONE DATE: 8/1/13 a AV mem®gym PERCOLATION RATE: 1.28 (MINUTES/INCH.) PERCHOLE DIAMETER: 6" TEST RUN BETWEEN: 5.0 FT. AND 5.5 FT. COMMENTS: THE SOILS WERE PRE-SOAKED PRIOR TO STARTING THE PERCOLATION TEST. PERFORMED BY: DHI CONSULTING ENGINEERS. I DEE HIGH CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 07/12/13 1038CSSlD PERCOLATION RATE: 1.28 (MINUTES/INCH.) PERCHOLE DIAMETER: 6" TEST RUN BETWEEN: 5.0 FT. AND 5.5 FT. COMMENTS: THE SOILS WERE PRE-SOAKED PRIOR TO STARTING THE PERCOLATION TEST. PERFORMED BY: DHI CONSULTING ENGINEERS. I DEE HIGH CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 07/12/13 1038CSSlD