HomeMy WebLinkAboutREBISCHKE LT 50ERebischke
Lot 50E
#050-252-18
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSP141291
05025218000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: August 25, 2014 to August 25, 2015
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: REBISCHKE
Site LegalAddress: REBISCHKE LT 50E G:0051
Owner/Address: DEPARTMENT OF HUD
34 CiViC CENTER PLAZA RM 7015 SANTA ANA CA 927014003
Site Mailing Address: 16323 POPPY LN, Eagle River
Lot Size in Sq Ft: 10747
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:,~._,
Issued By:
Date: ~:~ ~-~"~
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchoraqel Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww,muni.orqlOnsite
Development Services Division
On-Site Water and Wastewater Program
Department
**** VARIANCE/WAIVER REVIEW ****
WaiverS: OSPt4'1292 COSA#:
PID#: 050-252-18
Legal Description: Rebischke Lot $0E
Engineer: Garness En.qineerinR Group
Permit~: OSPt4t292
Applicant: Jordan Woods
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 5.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require ali separation distances be met or another
approval from this department.
[] The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
[] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
[] Adjacent properties are not affected by this waiver.
Waiver is Granted: X Waiver is not Granted.'
^ roved : _
.....
........................ L ?,..rn¥,~, .'~,v2t~,e:, ,,~ ......... ...,
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907- 343-7997
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. 050-252- 18
Property owner(s) JORDAN WOODS
Mailing address 16525 POPPY LANE * EAGLE RIVER, AK 99577
Day phone 529-6201
Site address 16525 POPPY LANE * EAGLE RIVER, AK 99577
Legal description (Sub'd, Block & Lot ) REBISCHKE; LOT 50E
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms
APPLICATION IS FOR: APPLICATION IS AN:
( [] all that apply) Initial []
Absorption Field []
Septic Tank [] Upgrade []
Renewal []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
LOT LiNE WAIVER
TYPE OF DEWELLING:
Single Family (SF) []
(w/wo ADU)
Duplex (D) []
Multiple Dwellings []
(SF and/or D)
Distance: 5 FEET
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No. (~-'~
Waiver Fees: ~"[~'~' --
DateofPayment: -flM'
Receipt Number: 0 {~"~H & -
Waiver No. 05 ¢l~l~'~'
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
July 25, 2014
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System Upgrade for Rebischke Subdivision; Lot 50E
To whom it may concern:
The existing 4 bedroom house is served by a private well and septic system. We are proposing
that a Quanics Aerocell treatment system (CAT II) be installed on this properly which includes
the installation of a 1500 gallon S.T.E.P. tank and trench type drainfield. Attached are a site plan
and a design drawing showing the proposed septic system. One test hole was excavated on the
property. The drainfield will be designed around the 30 foot radius of this test hole. Comments
regarding the design are summarized as follows:
1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring,
and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: As can be seen on the attached design, the average topography below the
drainfield is relatively flat. In shod, there are no slope concerns.
5. LOT LINE WAIVER: Due to site constraints, we are requesting a 5 foot lot line waiver from
proposed drainfield to the north lot line. There are no adjacent septic systems within 10 feet of
the proposed drainfields.
6. DRAINFIELDS TO CLASS "C" COMMUNITY WELL WAIVER: A 120 foot waiver is
required from a class "C' well on the adjacent property to the proposed septic system. This
waiver is being requested to ADEC. Once the waiver is issued we will provide you with a copy.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
Presid
P.E., M.S.
3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.c0m
Municipality of Anchorage
P.O Box 196550 4700 Elmore Road
Anchorage, Alaska 99519-6650 (907) 343-7904 Fax (907) 343-7997
http:llwww.muni.orglonsite
Planning and Development Services Department
On-Site Water and Wastewater Program
On-Site Sewer/Well Submittal Comment Sheet
=ngineer:
.egal Description:
GARNESS ENGINEERING GROUP LTD
REBISCHKE Lt 50E
8/14/2014
~ermit: OSP141291 Septic Completed By:
{eport Type: On-Site Review
D.Wockenfuss
'he attached paperwork has been reviewed and is being returned for the following reasons:
1. The foundation cleanout appears to be under a deck. Is it accessable? If not, please address.
2. Since the existing system is undocumented, an alternate site is required.,~-'--- .,.
3. Missing the AWWTS Maintenance Agreement. AMC 15.65.36~B ~
~ ~ .,~ ~ ~,~rL ?~-~,'4~.- C-~¢~;J~,'ri~'~r~ 'T'i'Yp¢~
LOT 4; SCHULTZ S/D" -~ LOT 3; SCHULTZ S/D
\\ BUILDING PER OWNER
SCALE:
LOT 51, SECTION
UN~ILTHATDAYCHURCH
PA~SONAGEPEROWNER
WATER
/
LOT 53C,
MCGANN
LOT 53D,
MCGANN S/D
LOT 536, I LOT 53A,
MCGANN S/D MCGANN S/D
LOT 53E,
MCGANN S/D
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL
PREPARED FOR: ~ PHONE NUMBER: PAGE NUMBER:
JORDAN WOODS I (907) 529-6201 1 OF4
LEGAL DESCRIPTION: DRAWN BY:
REBISCHKE S/D; LOT 50E J.L.M.
TYPE OF WORK: DATE:
~. SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM 7/25/2014
NOTE: THERE ARE NO EXCESSIVE
SLOPES WITHIN 50 FEET OF THE
PROPOOSED DRAINFIELD.
/
DESIGN CRITERIA:
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPD) : 600
~ERCOLATION RATE/S: <1 MIN./INCH
~ROPOSED APP. RATE: 4,0 GPD/SQ. FT.
~41NIMUM DRAINFIELD SQ.FT.: 150 SO.FT.
DRAINFIELD DESIGN:
MAXIMUM DEPTH: 6FEET
WIDTH: 5 FEET
LENGTH: 30 FEET
M.O.A APPROVED SAND FILTER: 2FEET
EFFECTIVE: 0,5 FEET
ACTUAL SQ,FT,: 150
LOT 50C
NOTE: THE CONTRACTOR SHALL
HAVE TH E 100 FOOT WELL RADII.
THE 120 FOOT WELL RADIUS. THE
NORTH LOT LINE AND THE EAST
LOT LINE FLAGGEB BYA
REGISTERED LAND SURVEYOR
PRIOR TO ANY CONSTRUCTION,
LOT 50B
SCALE:
1"=30'
(SEE DESIGN CRITERIA)
650 AEROCELL
MT
LOT 50D
EXISTING
EXISTING
WELL
EXISTING
GARAGE
EXISTING
4 BEDROOM
HOUSE
POPPY LANE
GARNESS uI ,.G E ROUP, Ltd
PREPARED FOR: I PHONE NUMBER: PAGE NUMBER:
JORDAN WOODS 529-6201 2 OF 4
LEGAL DESCRIPTION: DRAWN BY:
REBISCHKE S/D; LOT 50E J,L,M.
tYPE OF WORK: [ DATE:
~ DESIGN OF SEPTIC SYSTEM UPGRADE 7/25/2014
/ LOT 50A //
FOUNDATION
CLEANOUT
i LOT 50F \
PROPOSED 100' WELL RADIUS
STANDARD TANK CONFIGURATION
DIAMETER
TOTAL LENGTH
SHELL
COMPARTMENT A
~COMPARTMENT B
iNLET INVERT
HIGH WATER ALARM
OVERRIDE FLOAT
1500
07"
34" (
24" ( 36'1
NOTE: FLOAT LEVELS ARE FROM BOSOM OF PUMP ( ¢~ tS FROM BOI~OM OF TANK
ELECTRICAL WIRE/S (SUPPLIED BY CONTRACTOR)
SEE iNSTALLATION MANUAL FOR
24" iNSULATE
SIM/TECH PRES
UL L~STED SPLICE BOX
WITH 5 CORD CONNECTOR:
*
2" UL LISTED [
24" RISER. TOP 4 FEET
INSULATED WITH 2 INCHES
URETHANE W
PVC CONDUIT FOR ELECTRICAL
CONNECTIONS ( FLOATS & PUMP) ~
2" OF INSULATION OVER TANK ~
IS RECOMMENDED ON ALL
INSTALLATION REGARDLESS
OF BURIAL DEPTH
1500 GALLON S.T.E.P, TANK
SUPPLIED BY GREER TANK
10 GAUGE, RATED FOR 10' BURIAL
BAFFLE (SEALED) -WELDED
AROUND ENTIRE PERIMETER
QUANICS AEROCELL CAT. II
QUANICS AEROCELL SYSTEM
CATEGORY II CONFIGURATION
(3 TO 4 BEDROOM SYSTEMS)
3NTROL PANEL
WITH SENSAPHONE REMOTE MONITORING
SYSTEM AND OPTIONAL JANDY VALVE
ACTUATOR SWITCH (NO LOW LEVEL
ALARM TERMINALS) ,
qDE RIGID
INSULATION CENTERED
OVER PIPES
i QUANICS AEROCELL 650 TREATMENT MODULE
WITH INTERNAL DIVIDER WALL AND CLEANOUTS
· 4" BY 4'V ;iD
INSULATIC f CENTERED
OVER PIPE
/ - 4"VISUAL PORE
3E LINE
'; D DRAINFIELD
2" DISCHARGE LINE
DRAINFIELD. SEE APPROVED
ENGINEERED DESIGN DR,~ WING/S
HIGH WATER FLOAT
OVERRIDE FLOAT
~-1.25" SUPPLY LINE
~2" RECIRCULATION LINE
LOW LEVEL CUTOFF Fi. OAT (ON/OFF)
GOULDS PE51M OR EQUIVALENT
NOTE: ALL PIPE IS TO BE E- HEDULE
40 PVC UNLESS NOTED O, HERWiSE.j
INOTE: ALL PIPING FROM S.T.E.I I'ANKTO
AEROCELL MODULE SHALL BE PLACED ON
SUITABLE BEDDING MATERIAL 7HAT IS
MECHANICALLY COMPACTED. ALL LINES SHALL
BE GRADED SO THAT THEY WILL DRAIN AFTER
EACH PUMP CYCLE AND WILL NOT RETAIN ANY
STANDING WATER,
DESIGN CRITERIA: DRAINFIELD DESIGN:
NUMBER OF BEDROOMS: 4 MAXIMUM DEPTH OF EXCAVATION: 6 FEET
GALLONS PER DAY (GPD): 600 WIDTH: 5 FEET
PERCOLATION RATE/S: <1,0 MIN./INCH LENGTH: 50 FEET ~~~:_~°--~/
~v--....
MINIMUM DRAINFIELD SQ.~.: 150 EFFECTIVE: 0.5 FEET
*THIS IS A CAT II QUANICS SYSTEM ACTUAL SQ. ~.: 150
ORIGINAL GRADE ~ 4" OF INSU~TION BY 4
~ ' / FE~ WIDE OVER FEED LINE
~(HIGHEST POINT' / ' AND REC,RCU~TiON LiNE
~ ., 650 AEROOELL UNIT~ /
~ ~4 .CL~NOUT X / ~4' MONITORING TUBE
X / ;4 MONITORING TUBE ~" CL~NOUT2 5 / /~4" CL~NOUT
/ ~FILTER FABRIC ~ ~ ~
DEEP MAX. ~:~~ ~--~
": ..""C':-: ...~,. :::-....:::.;':.w' :.: .":.~..'..~,. ::.~ :.'":. ', .~.....:-.c..:',:':'c..:..:..,,.::<.'::. ';.::.:.', :~ :.., :.: .::: ~:~.'., .:.::,?... :,..:..::..,., :.., ~::..-,.:..-..: . :.,:......: ~
';..: "A.:' .;'0.5 EFFECTIVE~ ~ '.,[ ti: ,E,.,:,:::,':' .. ,.%. ,:.: .':; '.,'... '..:',:;:. :...:. '.:.:"',..' L.:'~ '.t.:;,:¢.' C: .", W....'.:::"::"'"..'"L, t,' .;..., :':~ .~::.."."': :.. '..'. '.:~::~1' / / / -
:...,..,~.,:.:..,.:'.~: ..... ,~.,,.:,:.:-,,..':.:.: ,...::,..,-.:....,'.,-~ o~ ~A., ~,,T~.:'.'::...':,,:~'.:' :: .~': ~,.:',.,'~,":::: ". :.:",: ,':,:":' :'..:,':'.:'. :"~ ':' '.~:~ / / /
,.1.~ "....;'"::L".;':,:~),::..:~. ~..: :.' ','.? L.:..::'.....'.::::t.:::::.:tt 1',.', ..:: :t.,z:.::;-.:'.'~,';:',': :: ~: -..:.':., ,.:.':':, t~ L .".?t;.:.'~ ~: ?:~ .:2, ,)L:.'c:z.::'?,",'::"::..:' .::,': :.':.':. ~Fq '"':· L:;L?C~::'.'~.,.,i :.: :'...'
.'."'....'~ ....... :-..., ~,.. ....... ~`:~:~`~:~:`~:~``~``~`~``:~:`~`~`~:~`:~~:.~ / / I
.
~30 FEET LON~ -~
SHALL BE INSULTED WITH 4" OF INSU~TION BY
4 FE~ WIDE AND CENTERED OVER PIPE. THESE PROPOSED 1500 GALLON
LINES SHALL BE INSTALLED SO THAT THERE ARE S,T.E.P. TANK WITH
NO BELLIES ON ANY PORTION OF THE LINES. QUANICS COMPONENTS
AND CONTROL PANEL
GARNESS ENGINEERING GROUP, Ltd
[SOIL LOG - PERCOLATION TEST[
LEGAL DESCRIPTION: REBISCHKE S/D; LQT 50E
PERFORMED FOR: JORDAN WOODS DATE: 7/18/2014
ORGANICS ITEST HOLE #1 I
LOAN (SM) SOIL CLASSIFICATIONS SITE PLAN
CL
OL
CH Ox&~
OH
SC
GP TO SP x,~t~'tJ'
DEPTH TO
GROUNDWATER DATE
DRY 7/18/2014
DRY 7/25/2014
WITH SOME
LARGE COBBLES
& BOULDERS
SCALE;
1" = 100'
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TildE (MINUTES) READING (INCHES)
7/18/2014 1 6"
2 <2 0" 6"
4 <2 0" 6"
6 <2 0" 6"
? 6"
8 <2 0"
9 6"
10 <2 0" 6"
PERCOLATION RATE <1 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 6 FT. AND 7 FT.
A FOUR HOUR PRESOAK WAS PERFORHED: [~YES 'NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JODY MAUS
COMMENTS: PERCOLATION READINGS ARE WlTHIN1/16OFINCH.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE~FOR.MED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:~·'---[~,~/' [.Iq
D}vision of ?stet
Waste,rater Discharge M~:horiza~ion ?rogram
~5,5 Co~cloYa Sit ool
Anchorage, A[asXa 99501
Main: (5'07)-269 7.519 Fclx:{907) 269-348/
July 3!, 2014
Jeffi:ey Garness, P.E.
Garness Engineering Group
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Re~
Eagle River - RebiscKke Subdivision, Lot 50B-Class "C" Well Separation Distance Waiver Application
from 150 Feet to 120 Feet from the Source Well to the Soil Absorption System-ADEC Plan Tracking
Number 10902
Dear Mr. Garness,
On May 29, 2014 the Deparm~ent received an engineering plan submittal requesting a waiver of the separation
distance to the existing Class "C" Source Well on Lot 50B to the planned new wastewater treatment plant and
disposal system being replace for the single family development on lot 50E of Rebischke Subdivision. The new
system on lot 50E will be within the Class "C" 150 foot well radius which is waivered to 120 feet. The older septi6
tank and field must be removed and properly disposed of off site. (per UPC, Appendix K).
Based upon the Engineer's recommendation and the submitted information a waiver for this application has been
determined to be protective of public health.
found to be failing or determined as endangering public health, the waiver is rescinded and corrective engineering
action will be require&
This approval does not imply the granting of additional authorizations nor obligate any state federal or local
regulatory body to grant required authorizations.
Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18 AAC
15.195 - 18 AAC 15.340 or an informal review by the Division Director in accordance with 18 AAC 15.185.
Informal review requests must be delivered to the Division Director, 555 Cordova Street, Anchorage, Alaska
99501, within 15 days of receiving the decision. Guidance information on the informal review process may be
found at http://www.dec.state.ak.us/commish/ReviewGuidance.htm. Adjudicatory hearings requests must be
delivered to the Commissioner of the Depm~nent of Environmental Conservation, 410 Willoughby Avenue, Suite
303, P.O. Box 111800, Juneau, Alaska 99801, within 30 days of the decision. Ifa hearing is not requested within
30 days, the right to appeal is waived.
Thank you for your cooperation. If you have any questions please do not hesitate to contact me at 269-7519.
Respectfully,
William R. Rieth, P.E.
Environmental Engineer