Loading...
HomeMy WebLinkAboutT15N R1W SEC 8 LT 215TISN RIW c. 8 #051 - 154- 38 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161098 Tax Code Number: 05115438000 Work Type: Septic Renewal Permit Effective Dates: May 16, 2016 to May 16, 2017 Design Engineer: ARC TERRA CONSULTING INC Subdivision: T15N R1 W SEC 8 Site Legal Address: T15N R1 W SEC 8 LT 215 G:1257 Owner/Address: WALISER ANTHONY 1919 SPENARD RD APT 2 ANCHORAGE AK 995030000 Site Mailing Address: 19649 SUNSET BLVD, Chugiak Lot Size in Sq Ft: 108900 Total Bedrooms: 1 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: A test hole shall be completed to verify the reserve drainfield design prior to construction. If the results require design revisions, an approved change order shall be issued prior to construction. The test hole results shall be submitted with the final inspection report. Receiv Issued MUNICIPALITY OF Community Development Department Development Services Division 0* On -Site Water & Wastewater Program Parcell.D. O$ / Property owner(s) Mailing address _ Site address Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERNVELL PERMIT APPLICATION Legal description (Sub'd., Block & Lot) T/ S N J�e ( L(' Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms APPLICATION IS FOR: (® all that apply) Absorption Field TYPE OF DWELLING: Septic Tank Single Family (SF) Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES Day phone 6 APPLICATION IS AN: TYPE OF DWELLING: Initial Single Family (SF) Upgrade ❑ (w/wo ADU) Renewal X Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above infHfidafion is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date n° t: 5haJ/¢ Date of Payment: Receipt Number: ` Receipt Number: Permit No. Waiver No. Permit App_9-1-12.doc Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP141246 05115438000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: August 26, 2014 to August 25, 2015 Design Engineer: ARC TERRA CONSULTING INC Subdivision: T15N R1W SEC 8 Site Legal Address: T15N R1W SEC 8 LT 215 G:1257 Owner/Address: WALISER ANTHONY 6931 HOWARD AVE ANCHORAGE AK 995041867 Site Mailing Address: 19649 SUNSET BLVD, Chugiak Lot Size in Sq Ft: 108900 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: If the owner elects to do the septic system installation himself, he shall first submit a signed letter to On-site stating: 1.His experience installing septic systems, 2.Who owns the equipment used for the installation, 3.That no one will be paid to help with the installation, and 4.That the owner will be present during the installation. Special Provisions: PRIOR TO CONSTRUCTION: A test hole shall be completed to verify the reserve drainfield design prior to construction. If the results require design revisions, an approved change order shall be issued prior to construction. The test hole results shall be submitted with the final inspection report. MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program ON-SITE SEWERfWELL PERMIT APPLICATION 051-154-38 Parcel I.D. Property owner(s) ANTHONY WALISER Day phone 6931 HOWARD AVE., ANCHORAGE, AK 99504 Mailing address Phone: 907-343-7904 Fax: 907-343-7997 SUBMITTAL JUL ] 4 2014 Site address 19619 SUNSET BLVD., CHUGIAK, AK 99567 T15N RIWSEC8 LOT215 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size 108,900 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: ([] all that apply) Absorption Field r)rI Septic Tank Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: TYPE OF DWELLING: Initial ~XI Single Family (SF) (w/we ADU) Upgrade [] Duplex (D) Renewal [] Multiple Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Sign~y owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. O5~ Waiver Fees: Date of Payment: Receipt Number: Waiver No. Perm Jr App_9-1-12.doc AI ¢TERI A CONSULTING~ INC 212 E. 51st Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 July 8, 2014 Mtmidpality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New Sewer Permit - T15N R1W SEC8 LOT 215 The owner has requested we proceed forward to obtain a septic permit to serve the proposed 3-bedroom house. The general slope of this lot is from southeast to northwest at a grade of approximately 15-20% over the septic area. On June 26, 2014 a testhole was performed to investigate soils and groundwater. The results of this test are attached for your review and show adequate soils to support a primary convenfional field or primary and reserve fields with an advanced wastewater system. Prior to construction, an additional testhole will be performed for a conventional or advanced reserve. We propose to install two 5-Wide 66' long trenches. Groundwater was not encountered at excavation or at monitoring. The property and adjacent lots are served by private water. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868- 3791 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Attachments: On-Site Sewer Applicafion Wastewater Absorption System Details/Site Plan Soils Log / Percolafion Test 20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 · PH (907) 868-3791 · FAX (907) 868-3793 WELL WASTEWATER DISPOSAL T15N SYSTEM DETAILS/SITE PLAN ]T 215 Z FLAG PROPERTY LINES WELL RADII & EASENENTS PRIOR TO CONSTRUCTION SccLe~ 1'= 100' DESIGN DETAILS PAGE 1 OF 2 3 BORN X 150 GPO = 450 GPO 450 GPI]/,60 GPI] PER SQ, FT, (23 HIN/IN,)= 750 SQ, FT (750 / 5 × ,87 RF (1' GRAVEL) = 138,5 FT. TRENCH USE 8 TRENCHES - 66' (L) X 5' (W) X I' (ED) Tomcat dep:ch oF sys:ceM is 8,5' Cron orlgln~t grade, To~t dep:~h o? gr~vei below distribution pipe Is 1' , NBTES~ i, INSTALL lO00 GAL SEPTIC TANK & INSULATE TANK IF <4' COVER, B, INSULATE TRENCHES WITH 8' HI] BURIAL FOAM IF < 3' OF FILL. MIN. B' FILL WITH INSULATION. >3' COVER NB INSUL REQ. 3. CONTRACTOR WILL ENSURE HINIMUH 2Z SLOPE INTO SEPTIC TANK, 4, CONTRACTOR WILL ENSURE ALL SEPARATIONS TO AI]JACENT WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC.., 6931 HDWAR'n AVE ANCHDRAGE, AK 99504 FIELD BOOKS .ou~. BOUNDARY s'r~i~e STAKING ~L~ JLS ~,e m~ FILE WASTEWATER DISPnSAL SYSTEM DETAILS T15N Ri~ SEC8 LOT 815 ADDI'flONAL BE FOR 11-114-1 T STALL NEW CO IO00-GAL SEPTIC ;NT NO. 1; 7701 BOC 414 PA( EXIS'nNG WELL ® FLAG WELL PRIOR PROPERTY LINES RADII & EASEMENTS TO CONSTRUCTION ~^w~: BMW cwEc~ KMD 08/07/09 NW1155 09-012 ~-~ O~P · PREPARED FOR' ~m .i ' I '".i~I~, ANTH[3NY ~/ALISER '" ~ ANCH~RA~[, AK 99504 ~ ~ FILE Scale, 1'= 30' PAGE 8 DF 8 /! , rSD%TiNO ~ CONSULTING, INC 212 E. 5la Ave, Anchorage, AK. 99503 office (~7) SOILS PERCOLA~ON ~ST Performed for: Anthony Waliser Date Performed: 6/26/2014 Project: Depth (Feet) T15N RIW SEC8 LOT 215 ORG/OL TEST HOLE # TH 14-1 SEE ATTACHED SITE PLAN FOR HOLE LOCATION GM Was Ground water encountered? NO What depth? NA Depth to water after monitoring? DRY Date? 7/5/14 Reading Date Gross Net Depth to Net Time Time Water Drop 1 6/27/14 1:00 6" 2 1:30 30 min 4 10/16" 1 6/16" 3 * 1:31 6" 4 2:01 30 min 4 11/16" 1 5/16" 5 * 2:02 6" 6 2:32 30 min 4 11/16" 1 5/16" 7 8 9 10 11 12 · Water Added 10- 11- 12- 13- 14- 15- 16- 17- 18- B.O.H. - BEDROCK 19- 20- HOLE PRESOAKED PRIOR TO TESTING Percolation Rate 23 (mirdin) Perc Hole Diameter__ Test Run Between 2 feet and 3 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Munidpal guidelines in effect on this date. MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 On -Site Water & Wastewater Program Fax: 907-343-7997 Septic System Owner -installer Agreement A real estate property owner (Owner) may install their own septic system. The department may issue an approval for a homeowner to perform work on a conventional (not AWWTS) on-site wastewater disposal system to serve that individual's owner -occupied, single-family or duplex home if the homeowner satisfies and agrees to the following requirements. The property owner and excavation equipment operator may perform work on no more than one owner installed pr%ect in a 12 -month period. As owner of (legal description) _:E/S-A/ (W SE c, J, I j- I agree the following items are true and accurate. My experience installing septic systems is as follows. The name of the excavation equipment operator is. ky0, h ,wd Wa (. fe, ( f-1-1 a) 3. There will not be compensation for installation services rendered. 4. 1 will be actively involved with the septic system installation at all times. The name of the inspecting engineer is 14r, e/d 6. 1 agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.150. C. 2 -hour minimum advance notice given to the On-site Water & Wastewater Program for all required municipal inspections. 7. 1 agree any changes I make to the items listed above will require a new approval before performing work. 8. 1 agree to have the project -specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. Owner's printed name: Yat - Owner's signature: 42!x Date: 114.rle IF Septic System Owner Installer Agreement_Feb2015.doc - by A & 1_, DRILLING COMPANY BOX 97, EAGLE RIVER, ALASKA 99577 · TELEPHONE 694-2588 OWNER OF LAND /.)r:],a~ ~ . ADDRESS LEGAL DESCRIPTION DATE - Started PERMIT NUMBER '-~?'7 S ¢.3 DEPTH OF WELL STATIC LEVEL OF WATER FT. Ended GALS. PER HR KIND OF CASING KIND OF FORMATION: From ~- _Ft. to From ~,:~ Ft. to From [ / Ft. to~TM From ~i~3 Ft. to ,From~ -~ Ft. to _Ft. From_ Ft. to From Ft. to Ft. From Ft. to Ft. From__Ft. to Ft. From__Ft. to _Ft. From__ Ft. to Ft. From__ Ft. to Ft. From Ft. to__Ft. From Ft. to Ft From Ft. to Ft. From Ft. to Ft. From_ Ft. to__ Ft. .Ft. 0 d&'~ t{ d~_~¢~J From Ft.~.'g/? ff 6Ac~q'/F~ q'/~o §' a.,:, ~ ~0 Ft. to Ft Ft. to From __ Ft. to__ Ft From Ft. to_ Ftc_ From Ft. to__ Ft. From Ft. Frmn__ Ft. to___Ft. From Ft. to___Ft. From__.Ft. to __Ft. From__ Ft. to_ Ft.__ From__Ft. to. Ft, From_ Ft. to __Ft. From Ft. to Ft From_ Ft. to Ft. From Ft. to Ft. From___Ft. to Ft. From_ Ft. to___.Ft MISCL. INFORMATION: DRILLER'S NAME ' ' ' ' : ......... t...I ....I,I I I:::1 'F' I I'., I...IE GI:::tl ....