Work Type:
On-Site Wastewater Disposal System Permit
OSP141448
01614116000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Depadment
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: November 05, 2014 to November 05, 2015
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: SNOW CREST VIEW
Site Legal Address: SNOW CREST VIEW LT 16 G:2630
Owner/Address: THOMPSON TYSON W
11430 LILLIAN LN ANCHORAGE AK 995150000
Site Mailing Address: 11430 LILLIAN LN, Anchorage
Lot Size in Sq Ft: 8910
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Qpen and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 016-141-16
Property owner(s) Tyson Thompson
Mailing address 11430 Lillian Lane, Anchorage, AK 99515
Day phone
Site address 11430 Lillian Lane
Legal description (Sub'd., Block & Lot) Snow Crest View, Lot 16
Legal description (Township, Range & Section)
Lot Size 8,910 _Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
([~ all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
APPLICATION IS AN:
TYPE OF DWELLING:
Initial [] Single Family (SF)
(w/we ADU)
Upgrade []
Duplex (D)
,Benewal [] Multiple Dwellings
Privy [] ~t~,~lil~/~4z (SF and/orB)
Private Well []
Water Storage [] ('/~'/' ,,
.
THIS APPLICATION INCLUDES A~VAR ANCE / WAIVER REQUEST FOR:
-~C~ ¢~-r~¢,(-¢~0) LC' &,~,'~"cz~ -r-~ ~ ~.., . Distance:
I certify that the above information is correct. I fudher c8rtify that this is in accordance with
applicable Municipal Codes.
(Signature of properly owner or authorized agent)
Permit/Rush Fees: ~,~ '"
Date of Payment: lo1 1,'
Receipt Number: O~. (,,.'~ ~. (~
Permit No. 6)"PCI~ i~"~t~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_£- :. :2..:c.'
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-maih steveC~panengak.com
September 30, 2014
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P. O. Box 196650
Anchorage, Alaska 99519
Subject:
Snow Crest View, Lot 16
Septic System Permit Request
Ladies and Gentlemen:
I am writing to request a permit to install an upgrade septic system be issued for this property. The
proposed systems will serve an existing three bedroom (3) bedroom house. Currently the lot is developed.
The existing drain field and tank are in failure and will be decommissioned per code. A new upgrade
1000g septictank and drain field will be installed. The surrounding lots to the north, south, and west are
developed and served by private septics with a community class 'A' well PWSID# 2210891 that is located
150' from the proposed tank and 170' from the proposed drain field. PES has applied for a separation
distance waiver from the ADEC for this system to the class'A' well.. The lots to the east are served by
private wells and septics. The private wells are located over 100' from this system.
Soils. One test holes were performed by Pannone Engineering Services in September of 2014, and
groundwater was monitored for seven days. Ground water was not observed after the seven day
monitoring period. It is my opinion, based on the results of the percolation tests and overall soils
appearance; an application rate of 0.8 gallons/day/square feet should be used for a conventional
wastewater system.
Soil Absorption System Design.
a. See Sheet 2 of the design package.
2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
3. Topography: The existing topography slopes from the south to the north at approximately 3%.
There are no steep slopes in the vicinity of the drain field.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Pa§e 2 of 2
4. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On-Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no surrounding wells within 100 feet of the proposed septic location. We have applied to the ADEC for
a separation distance waiver from the class 'A' well.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
'~ ~ WELL (E) J -~ 92 ~
~ SEPTIC AREA (E)
150.5 170.5
TO CLASS 'A' WELL
/
"~~ RESERVE DRAIN FIELD (NIC)
. ~ . ~ ' .30LFx 3'W x 100'EDx !50'TD
~ ' i- A Vv'AWER FROM ADEC MUST BE OBTAINED
I ~ ~ ~ X, ~ P~IOR TO RESERVE SITE PERMITTING
~ /I J/ / ~ ~ k / AND CONSTRUCTION.
u] ~ ~ ~ ," , TH I' '
~ 3DR '~ ~~ ~ / I REPLACEMENT DRAIN FIELD (P) .
~ ~ ~ / N230/ / I', ~ ' X, 153.7
ABANDON PER CODE ~ ,ORIGINAL UNDOCUbIENTED ORAIN FIELD
IN2TALL SEPYIC TANK (P) ~ ~. AB.,NDON PER CODE '
WITH - ,CLEAN OUT i I
~DOUBLE
iL ~TURN AROUND
x~ ~- I EASEMENT
-' ~ l
W ~ ~-~ -SEPTIC AREA (E) SEPTIC AREA
~*.'4 ~ '.*l
SNOW CREST VIEW, LOT 16 ~
S~even R. Ponno~e~
TYSON THOMPSON ~.. CE 8~9 ..~ PEeM~
11~30 LILLIAN LANE ~Ii -. ...... .
PLAN ANCHORAGE, AK 99515 ~?e0rESS~0~ Sh~
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS.
2. SCOPE OF WORK: ABANDON EXISTING UNDOCUblENTED SEPTIC SYSTEM PER CODE. INSTALL 10009 SEPTIC TANK WITH
DCO, AND SOIL ABSORPTION BYSTEM.
5 GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF~ 21 FEET BELOW EXISTING GRAOE AS EVIDENCED BY THE SOIL
TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 21 FEET BELOW
EXIBTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
~ ~0.0 ~
bg ,
I
SECTION
~= o o~o o 8 8 o
I
PROFILE '='~'~ a~¢s'~ ~'~ ~ ~ ABBREVI&TIONS
DESICN PARAMETERS :. ~-.~s¢~;:x.~;~.:~¢:;a¢-, A DIP DUCTILE IRON PIPE
NO. BEDROOM: 3 (450 gpd) LEGEND FC FOUNDATION CEEAN OUT
TANK SIZE: 10009 T~ TANK CLEAN OUT NO.
PERC RATE: 2.9 MPI W WATER LINC/ C~ CLEAN OUT NO
SOIL RATING: 08 6PD/SF ~ELL RADIUS bi{ MONITOR TUBC NO.
AREA ROD: 562 SF RI RIGID INSULATION
SYS TYPE: DEEP TRENCH 100'ED -- SS -- NEW SEPTIC BCD DOUBLE CLEAN OUT
DSE: FS FLOW SPLITTER
~0 LFx3 0'WxlO 0' ED, 15.0' TD BFG BELOW FINISH GRADE
TOTAL AREA: 600 SF GO ORIGINAL GRADE
FO FINISH GRADE
TSaV TOPSOIL ~ND VEGETATE
,oxs: ENG LLC I,
FOR CONST~UCTaON P.0. BOX 100217 ~NCHORAGE, AK 995~0 " " ~a sco~v~
N0
SNOW CREST VIEW, LOT 16 ~ --
TYSON THOMPSONr~-~i~'.. CE 8149 ..~ PERMIT NO
114.50
LfLLIAN
LANE
f~.i '. ...... .
DESIGN DETAILS ANCHORAGE, AK 99,515 ti. taPBOFESSt¢~~.~_ -~ Sheet
TESTHOLE1
FILL SANDY FILL
ORGANICS AND
OR/GL ORGANIC SILTS
SW VERY FINE SAND
BOH
DATE PERFORMED: 9/12/14
SLOPE
iX TH
SOILS LOG - PERCOLATION TEST
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH? -DRY
DEPTH TO WATER AFTER
MONITORING? -DRY
DATE: 9/24/14
SLOPE
TH
X
WATER
READING DATE CLOCK NET TIME LEVEL NET DROP
TIME READING
1 9/12/14 10:20 j --- 4-1/4
2 10:30 10 MIN 8-3/4 4-1/2
3 10:30 ... 4-1/4 .__
4 10:40 10 MIN 8-0 3-3/4
5 10:40 ... 4-1/4 ___
6 10:50 10 MIN 7-3/4 3-1/2
PEROLATION RATE 2,9 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 8 FTAND 9 FT
COMMENTS: Test hole excavated by A+ HOME SERVICES, Prec hole was presoaked.
Test run for at least one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC, LLC
FOR CON%T*UCTION P.O. @0X 102954 ANCHORAGE. AK 99510 ~?' '~'¢, Scae
PHONE (907) 272-8218 FAX (907) 272-8211
~*.' 49 m [ NTS
SNOW CREST VIEW, LOT 16 ~ ~16-141-16
I ~teven R. Pannoae~
TYSON THOMPSON ~., CE 8149 ..~ PERMIT
11430 LILLIAN LANE ~ .. ...... .
SOILS LOC ANCHORAGE, AK 99515 *~?8oEsa~ Sheet
Well 1~o..
Department of Environmental
Conservation
DIVISION OF ENVIRONMEN FAL HI~ALT}t
Drinking Water Program
700 E Bogotd ~d, g[dg B S~e 103
November 5, 2014
Steven Pannone, P.E.
P.O. Box 100217
Anchorage, AK 99510
RE: Snowcrest View South Separation Distance Waiver
PWSID #: 2210891; Community Water System; Source: Ground Water
Dear Mr. Pannone:
On October 23, 2014 this office received a separation distance waiver request for the Snow Crest View South
community water sys tern. 712qe on-site wastewater disposal system serving the home located on Lot 16 Snow (;rest
Viexv South subdivisinn bas recently failed and a new system has been designed to replace it. The waiver request is
for the following lesser separation distances:
150 feet between the septic tank and the community water source (50 feet less than the required separation
distance of 200 feet); and
170 feet betxveen the drainfield and community water source (30 feet less than the required ~ninimum
separation distance of 200 feet).
In your enginee£mg report you provided the following justifications for the lesser separation distances:
I. The well has a total depth of 74 feet, and is cased the entire depth. The static water level is approx/mately
30 feet below the ground surface;
2. Groundwater in the area typically flows from the southwest to the northeast which would direct potential
contamination at the site away from the welt;
3. The new wastewater disposal system serving Lot 16 will be located further away from the xvell than the
system it is replacing; and
4. Because the water system is a community water system, it is tested regularly for contaminants. ~llqe
sampling records for this water system show that k has been consistently free of total coliform bacteria and
as of October 25, 2013 the nitrate/nitrite levels are undetectable.
Although the separation distance between the well and the wastewater system components is less than the distance
prescribed by regulation, based on specific site conditions and the mitigating factors listed above, the potential for
contamination due to the lesser separation distance appears to be low. Therefore, a waiver for the lesser
separation distance described above is approved in accordance with the provisions of the State's Drinking
Water Regulations.
Approval Limitations
Tbis waiver is valid only for the proposed use and the system described in the waiver request on file hq this office,
This approval does not imply the granting of additional authorizations, nor obligate any federal, state or local
regulatory body m grant required authorizations. 21tis is not an approval of onfissions or oversights by this office
Steven Pannone, P.E. 2 November 5, 2014
or noncompliance with any applicable regulation. The Dep~tment's ~vaiver approval does m,t guarantee
correcmess of the functional design or waive the ow'net's responsibility for continued compliance xvith State
regulations.
Appeal Process
Any person who disagrees with fi'ds decision may request an adjudicatory hearing in accordance with
I8 AAC 15.I95 ~ 18 AAC 15.340 or an informal review by the D/vision Director in accordance with
18 AA(; 15.185. Requests for an adjudicatory hearing or informal review may be made by mail, electronic mail, or
facsimile. Informal review requests must be delivered to the Division Director, [';tame Busse Floyd, 555 Cordova
St., Anchorage, AK 99501, within 15 days of receipt of this decision. Adjudicatory heating requests must be
dehvered to the Commissioner of the Department of Environmental Conservation, Larry Hartig,
410 Willoughby Ave., Suite 303, Juneau, AK 99801, within 30 days of this decision. If a hearing is not requested
within 30 days, the tight to appeal is waived. More reformation on the Departmear's admimstrative appeals process
can be fotmd at http://www.dec.state.ak.us/commish/Review(}uidance.htm.
If you have any immediate questions regarding this waiver review, please don't hesitate to contact me at 3764846,
or via email at jacob.dilley@,ala~ka.gov. Although this approval is being granted from the ADEC Drinlmag Water
Program's Wasllla office, please refer all fnmre correspondence regarding projects in the vicimty of Anchorage to
the Anchorage Office at 269-7623.
Slncerely,
Jacob Dilley
Environmental Engineering Associate
Alaska Department of Environmental Consercation
Drinking Water Program, Wasllla Office
cc: Roy Robertson, DE(;, Drinking Water Program - via email