Well Log
Permit Number:OSP151044 Date of Issue: 3/10/15 Parcel Identification Number:
Date Started: 3 23 15 Date Completed: 3/23/15 Is well located at approved permit location? (xJ Yes U No
Legal Description: Galatea Estates blockl Lot21 G:2133
Property Owner Name & Address: McKinley Builder, Inc.
1120 Huffman Rd STE 24-530
Anchorage, AK 99515
Borehole Data: Depth (ft)
Soil Type, Thickness & Water Strata From To
Stickup
0
2
overburden
2
6
silt & gravel
6
25
moist silt & gravel
25
30
dry silt & gravel
30
42
moist silt/clay w/ gravel
42
60
silty gravel w/ H2O
60
65
clay/ gravel layer
65
72
72
81
coarse gravel w/ H2O
Water Sample Results: t
Arsenic: Zlug/L
Nitrates: ��tt-VDmg/L
Total Coliform BacteriaktRANI colonies/100mL
Other Bacteria: kkq—oa ✓2col/IOOmL
Method of Drilling U air rotary U cable tool
Casing type: steel
Wall Thickness: .250 inches
Diameter: — 6 inches Depth: 81 feet
Liner Type:
Diameter: inches Depth: _ loot
Casing stickup above ground: 2 feet
Static water level (from ground level): 14 feet
Pumping level: 3 feet after
4 hours pumping 10 gpm
Recovery Rate: 30 gpm
Method of Testing: airlift
n Open F,nd ❑ Open Hole
® Screened Start 76 feet Stopped 81 feet
n Perforations Start feet Stopped feet
20' Start 0' feet Stormed 20' feet
Pump: Intake Depth feet
Pump size hp Brand Name
Well Disinfected Upon Completion? 91 Yes ❑ No
Method of Disinfection: chlorine
Comments:
Well Driller: Hefty Drilling, Inc.
3540 Akula Dr.
Anchorage, AK 99516
Attention: The well driller shall provide a well log to DSD within 30 days of completion.
Development Services Department
Building Safety Division
' On -Site Water & Wastewater Program `` e°
4700 Elmore Road
P.O. Box 196650 <Ira 0"
Mark Begich Anchorage, AK 99507
Mayan www.muni.org/onsite
(907)343-7904
Pump Installation Log
Well Drilling Permit Number:4w- W 15I 01{q Date of Issue:
Parcel Identification Number:
Legal Description /' C O 0.,}C0. K� ` G 1 ' @
v L �` Tv7
Cie"s�
133
Property Owner Name & Address:
M - C -K i h k X31~; r aces Vic,
1 r10 14 ol, U • 4i 24-
211's
Pump Installation Date: S- 31- 15
Pump Intake Depth Below Top of Well Casing: 7o feet
Pump Manufacturer's Name: l rte 445
Pump Model: 10 506 0710- 2 V V
Pump Size YZ hp
Pitless Adapter Burial Depth: /0 feet
Pitiess Adapter Manufacturer's Name: %3-10
Pitless Adapter Installer: w� 0YA11..5 c.
1
Well Disinfected Upon Completion? ( Yes n No
Method of Disinfection:
Comments:
Pump Installer Name:
r
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
On-Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151044
Tax Code Number: 01410346000
Work Type: Well
Permit Effective Dates: March 10, 2015 to
Design Engineer: ANDERSON ENGINEERING
Subdivision: GALATEA ESTATES
Initial
March 09, 2016
Site Legal Address: GALATEA ESTATES BLK 1 LT 21 G:2133
Owner/Address: MCKINLEY BUILDER INC
1120 HUFFMAN RD STE 24-530 ANCHORAGE AK 995150000
Department
Site Mailing Address:
Lot Size in Sq Ft: 7766
Total Bedrooms: 4
This permit is for the construction of:
N Disposal Field N SepticTank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343~7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: t. Date
Issued By: t ~ ,,'" v.~. ~_- - ,Date:
V
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
~ Phone:907-343-7904
Fax:907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 014-103-46
Property owner(s) McKinley Builder, Inc.
Mailing address 1120 Huffman Road, Suite 24-530
Day phone
site address Zurich Street Anchorage, AK 99507
Legal description (Sub'd., Block & Lot) Galatea Estates, Block 1, Lot 21
Legal description (Township, Range & Section)
Lot Size 7,756 .Sq. Ft. Number of Bedrooms Four
APPLICATION IS FOR:
([~ all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Pdvate Well []
Water Storage []
APPLICATION IS AN:
TYPE OF DWELLING:
Initial [] Single Family (SF)
(wlwo ADU)
Upgrade []
Duplex (D)
Renewal []
Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Dis tance:
certify that the above information is correct. I further certify that this is in accordance with
(SignatL~re of property wner or authorized agent)
PermitJRush Fees:
Date of Payment:~
Receipt Number:
Permit No. ~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Mamh 9, 2015
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 Elmore Road
Anchorage, AK 99519-6650
Su~e~:
Lot 21, Block 1, Galatea Estates Subdivision
Well Construction Permit
Dear Onsite Services Engineer:
The owner of the subject lot intends to construct a new home on the site. No water
main fronts the lot and now water service is available. We are therefore requesting a
permit be issued to construct a pdvate well on the lot. The location of the well is shown
on the attached Site Plan. The lot is surrounded by the AWWU sewer system and a
new service will be extended to the home. The lot is small however and the location of
the well is critical.
The well will be placed at back of the house near the middle of the lot. At this location it
is more than 100' from the sewer main and all sewer man holes, it is also more than
25' from the sewer service to be constructed on the lot. The lot to the south is currently
vacant and cannot be developed until Zurich Street is constructed.The lots to the
north and west are served by the AWWU sewer and water systems.
The location of the well and the proposed location of the house and sewer service on
the lot will not impact adjacent properties. If the well and sewer service are constructed
in accordance with our design the following statements apply:
The well, if constructed as designed, will have no adverse impact on the wells in
the area or those to be constructed in the future.
The well, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The well, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
Lot 21, Block 1, Galatea Estates
March 9, 2015
Page Two
The well, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
Zurich Street
8" DIP Sewer
NOTE:
NO Conflicts with Sewer or
Woter on This Lot. LOT 1