HomeMy WebLinkAboutRAPTORS KNOLL LT 2Raptors Knolls Lot 2 #017-101-59 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151049 Tax Code Number: 01710159000 Work Type: Septic Initial Permit Effective Dates: April 30, 2015 to April 29, 2016 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: RAPTORS KNOLL Site Legal Address: RAPTORS KNOLL LT 2 G:3037 Owner/Address: RAPTOR PROPERTIES LLC 5725 YUKON CHARLIE LOOP ANCHORAGE AK 995020000 Site Mailing Address: 14135 RAPTORS KNOLL CIR, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Lot Size in Sq Ft: 49953 Total Bedrooms: 6 N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: The primary drainfield shall have design verification test holes (including USC classification, 7 -day groundwater monitoring and percolation testing) in accordance with the code completed prior to construction. If the test hole results do not support the permitted design, an approved change order shall be obtained prior to construction. Test hole results shall be submitted with the final inspection report. eon v�ev:ses uhf 6V'K%"'�C1a. f j Received By: Date: f/I 1 -7ci Issued By: Date: sd SUBMITTAMUNICIPALITY OF ANCHORAE MAR 17 2015 ® Gretchen StUller Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-101-59 Property owner(s) Raptor Properties LLC Day phone Mailing address 5725 Yukon Charlie Loop, Anchorage, AK 99502 Site address Raptor's Knoll Circle Legal description (Sub'd., Block & Lot) Raptor's Knoll, Lot 2 Legal description (Township, Range & Section) Lot Size 49,953 Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (E all that apply) Absorption Field ❑X Initial ❑x Single Family (SF) ❑X (w/wo ADU) Septic Tank 19Upgrade EJDuplex (D) ❑ Holding Tank F1Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. property owner or autnorizea Permit/Rush Fees: q _ Waiver Fees: Date of Payment: Date 1/Jr Date of Payment: Receipt Number: Receipt Number: Permit No. �S/��5loy Waiver No. Permit App_.::L..:c. Pannone Engineering Services uc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(@ioaneneak.com March 16, 2015 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. O. Box 196650 Anchorage, Alaska 99519 Subject: Raptor's Knoll, Lot 2 Septic System Permit Request Ladies and Gentlemen: I am writing to request a permit to install a new septic system be issued for this property. The proposed systems will serve a proposed six (6) bedroom house. Currently the has a well installed, but is otherwise undeveloped. The proposed system will utilize a 20008 septic tank with a conventional drain field. The surrounding developed lots are served by private wells. There are no wells on surrounding lots within 100 feet of this system and there are no septic systems installed on the surrounding lots within 100 feet of the proposed well. Soils. Two test holes were performed on this lot by Michael E. Anderson in May of 2013, and groundwater was monitored for seven days. Ground water was not observed below the surface in the test hole monitor tube in May of 2013. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 0.6 gallons/day/square feet should be used for a conventional wastewater system in the area of these test holes. Due to the proposed location of the house and the existing test hole's location in the central portion of the lot I request that the permit for this system be issued with the condition that a permit be issued with the condition that a test hole and ground water monitoring be performed in the location of the proposed drain field before construction is begun. The septic system is designed in the location of the septic reserve area and is based on a conservative application rate of 0.45 GPD/SF. The surrounding test holes in the area all show similar soil to the holes on this lot and the percolation rate is less than 30 minutes per inch in all nearby test holes. Additionally if adverse conditions are found in the proposed test holes the reserve drain field shown in the vicinity of TH-3 can be constructed based on CAT III. 1. Soil Absorption System Design. a. See Sheet 2 of the design package. 2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 3. Topography: The existing topography is relatively flat in the area of the proposed drain field and slopes from the east to west at approximately 20%-25% in the western portion of the lot. There are no steep slopes within 50' of the proposed drain field. The proposed drain field will maintain 50' separation all steep slopes. 4. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no surrounding wells within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 C0� \ \ \ WELL (P) A i \ BY OTHERS ( ) \\ u + a 0 J M '\ J M �- \ AA J �+ \ \ \ � -tl SEPTIC AREA (P) i BY OTHERS (NIC) \� WELL (P) 1 BY OTHERS (NIC) DRAIN FIELD (P) a \ �`'' � � WELL',(E) 70LF x 25•W x 8S`ED u 13.0'TD I <z a I �w . TH-4 LOT 2 wl l �w �� o 34 6 BR HOUSE U O O w�� 1�1/ W t (P) Y � d 24.4 Qv``'i V Iz 2 O Q PARKING \ SPACES TH-3 TH—PES-1 3: DRIVEWAY RESERVE DRAIN FIELD (P) _ 151-F x 2.5'W qx 8.0'EnD x 1113.0'TD 2000g SEPTIC TA� 3D�SQ0 OI N l P� WITH DCO AND FLOW SPLITTER / \' RIGID INSULATION (P) �` \ UNDER DRIVEWAY/ _ \ M M -inn _ `• � SEPTIC AREA (P) BY OTHERS (NIC) NOTE: \ `\ WELL (P) ANY SLOPE WITHIN 50' OF BY OTHERS (NIC) \ E\ DRAIN FIELD WILL BE 4:1 OR FLATTER. �, A V �� A I NOTES: PAMONE ENG SVC, LLC P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 _—��� N> �(G QF Al_j> sj 1 J l %6j�P �y+f TH .. .. ... .... Date 4/29/2015 CHANGE ORDER Scole RAPTOR'S KNOLL, LOT 2...../ P.I.D. NO 017-101-59 RAPTOR PROPERTIES LLC RAPTOR'S KNOLL CIRCLE S'te'ven R. Pa'n' CE 8149 �r�/ S PERMIT NO. osP1s1o49 Sheet 1 OF 4 PLAN ANCHORAGE, AK 99516 (�lo ► 1>1SS10NP• � '\� `��� SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS. 2. SCOPE OF WORK: INSTALL NEW 2000g SEPTIC TANK WITH DOUBLE CLEAN OUT, FLOW SPLITTER, AND SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 19 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE (TH-3) AND TH-PES-1. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 19 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. RIGID INSULATION UNDER DRIVEWAY 2000g SEPTIC TANK (P) DESIGN PARAMETERSa� PRIMARY SEPTIC SYSTEMF-PI-0�'M NO. BEDROOM: 6 (900 gpd) TANK SIZE: 2000 PERC RATE: 3.7 MPI - SOIL RATING: 0.8 GPD/SF ABBREVIATIONS R.I. RIGID INSULATION AREA ROD: 1125 SF CU COPPER _ DCO DOUBLE CLEAN OUT SYS. TYPE: DEEP TRENCH 85E DIP DUCTILE IRON PIPE DV DIVERTER VALVE MIN LENGTH: 66 LF TH TEST HOLE FS FLOW SPLITTER FC FOUNDATION CLEAN OUT BEG BELOW FINISH GRADE USE: - T# TANK CLEAN OUT N0. OG ORIGINAL GRADE 70 LFx2.5'Wx8.5' E.D., 13' TD FG FINISH GRADE TOTAL AREA: 1,200 SF C# CLEAN OUT NO. _ TS&V TOPSOIL AND VEGETATE - - M# MONITOR TUBE NO. NIC - NOT IN CONTRACT NOTES: �� T T _���� �� Dote CHANGE ORDER PAMOoNE7 EN ORALE CK 9 5,10 '���F'A`gStt) 4/29/2015 Aw . •. F I Scale PHONE (907) 272-8218 FAX (907) 272-8211 '0" ,49 *��, rs ... ... ..... P.LD. NO RAPTOR'S KNOLL, LOT 2/ a—m1-59 RAPTOR PROPERTIES LLC 5'te've'n 'R"n 5an''6nW PERMIT NO. �^ OSP151049 RAPTOR'S KNOLL CIRCLE �� cs,�� DESIGN DETAILS ANCHORAGE, AK 99516 111\\ OESSION Sheet OF 4 TH-3 FILTER FABRIC 4" m DRAIN PIPE DRAIN ROCK S" ABOVE PIPE INV TH-PES-1 -1.0 OR OL _ OR/OL —20 4.5 LEGEND J W WATER LINE/ WELL RADIUS GM GM 8.5 — SS NEW SEPTIC L - 6.0 6.0 -19-D � m a Or 7 O 0 O p s O p O ¢� pZ Z w� Z Z N Z w Z Z Z Q 7w w W mw J .� O O OV V U QU 4 n n n n RIGID INSULATION UNDER DRIVEWAY 2000g SEPTIC TANK (P) DESIGN PARAMETERSa� PRIMARY SEPTIC SYSTEMF-PI-0�'M NO. BEDROOM: 6 (900 gpd) TANK SIZE: 2000 PERC RATE: 3.7 MPI - SOIL RATING: 0.8 GPD/SF ABBREVIATIONS R.I. RIGID INSULATION AREA ROD: 1125 SF CU COPPER _ DCO DOUBLE CLEAN OUT SYS. TYPE: DEEP TRENCH 85E DIP DUCTILE IRON PIPE DV DIVERTER VALVE MIN LENGTH: 66 LF TH TEST HOLE FS FLOW SPLITTER FC FOUNDATION CLEAN OUT BEG BELOW FINISH GRADE USE: - T# TANK CLEAN OUT N0. OG ORIGINAL GRADE 70 LFx2.5'Wx8.5' E.D., 13' TD FG FINISH GRADE TOTAL AREA: 1,200 SF C# CLEAN OUT NO. _ TS&V TOPSOIL AND VEGETATE - - M# MONITOR TUBE NO. NIC - NOT IN CONTRACT NOTES: �� T T _���� �� Dote CHANGE ORDER PAMOoNE7 EN ORALE CK 9 5,10 '���F'A`gStt) 4/29/2015 Aw . •. F I Scale PHONE (907) 272-8218 FAX (907) 272-8211 '0" ,49 *��, rs ... ... ..... P.LD. NO RAPTOR'S KNOLL, LOT 2/ a—m1-59 RAPTOR PROPERTIES LLC 5'te've'n 'R"n 5an''6nW PERMIT NO. �^ OSP151049 RAPTOR'S KNOLL CIRCLE �� cs,�� DESIGN DETAILS ANCHORAGE, AK 99516 111\\ OESSION Sheet OF 4 4" JIM 4" PUMP - SLIDE SEC - OF 6" 1 OVER THIS CONNEC TO PROS SNEER PROTECTIU11— EXTEND TO BRIDGE EXCAVATION ADVANTEX DESIGN (2EA) ADVANTEX �h„ PASSIVE AIR VENT 10 GAUGE 2500 GALLON ANCHORAGE TANK ADVANTEX TANK Per D.M - NO. BEDROOMI 6 (900 gpd) ATA K SIZE: 00 ADVANTEX TANK IT A) AX20 PODS PERC RATE: 29 MPI - SOIL RATING: 4 GPD/SF AREA ROD: 225 SF SYS. TYPE: DEEP TRENCH 8.0'ED MIN LENGTH: 14.1 LF USE: 15 LFx2.5'Wx8.O' E.D., 13.0' TD TOTAL AREA: 240 SF NOTES: P,oNaOt0NE7 ENG'SVC, 99510 PHONE (907) 272-8218 FAX (907) 272-82116j�P T�������\\ OF AC kkk1 Ny ��� • •' .. P teveR 8149 Pannone CEm % I c^••, �/ l\��___ �? Date 4/29/2015 FOR CONSTRUCTION Scale NTS• P.LD. NO on -101-59 PERMIT NO. OSP151049 RAPTOR'S KNOLL, LOT 2 RAPTOR PROPERTIES LLC RAPTOR'SKNOLL CIRCLE ANCHORAGE, AK 99716++'l1E�FDNF5510�N�� SITE, SECTION Sheet 3 OF 3 TEST HOLE 1 ORIOL ORGANICS/ 1 ORGANIC SILTS 2 3 4 5 6 7 8 9 GM SILTY GRAVEL 10 11 12 13 14 15 16 17 18 19 BOH DATE PERFORMED: 5/22/15 COMMENTS: col SOILS LOG - PERCOLATION TEST SLOPE 'P SITE PLAN O I TH'-4 T X TH O 6 BR / HOUSE f / (P) WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -DRY DEPTH TO WATER AFTER MONITORING? -DRY DATE: 5/29/15 TH-3 DRIVEWAY i SLOPE TH X TH—PES-1 1. � READING DATE CLOCK WATERTIME NETTIME LEVEL READING NET DROP 1 5122/15 10:45 --- 5.40 2 10:55 - 10 MIN 8.63 3.23 3 10:55 --- 5.40 --- 4 11:05 10 MIN 8.13 2.73 5 11:05 --- 5.40 --- 11:15 10 MIN 1 8.10 2.70 PEROLATION RATE 3.7 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 5 FT AND 6 FT Test run for at least one hour. Last 3 readings reported - PERFORMED BY: Steven R. -Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES:ate PANNONE ENG SVC, LLC OF A� V>, 40/29/2015 CHANGE ORDER P.O. BOX 102954 ANCHORAGE, AK 99510 J �� qS �) Scale PHONE (907) 272-8218 FAX (907) 272-8211 j �, 9 �� NTS / .. RAPTOR'S KNOLL, LOT 2 .. .. .W 917-101-59 Steven R. Pannone PERMIT NO. RAPTOR PROPERTIES LLC y. CE 8149 '0,.'/ RAPTOR'S KNOLL CIRCLE j ./� OSP151049 SOILS LOG ANCHORAGE, AK 99516 +�liF��o�Esso�P�� Sh4eett 4 \� `PO OF Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci. anchorage. ak. us (907) 343-7904 Soils Log - Percolation Test Performed For: Ray Nickel Date Performed: Feb B, 2013 Legal Description: Timber Trail Subdivision, Lot 2 Township, Range, Section: SIope I I I I I Site Plan 1- 2-. (Feet) b ie Net Thune Depth to Water 3- 1 2/14/2013 4- t" D •r 5- 2 r� ` M �`�i 6- 7- 8 3 WW 9- 10- aii)� 11- 30 `` 1125u 12- 5 13- G�D�ie 15-I 1I'm 1') 16- Abp r 17- f 18- 19 T -NA WAS GROUND WATER d ENCOUNTERED? . 5 IF YES, AT WHAT DEPTH? L Depth to Water Atter o P Monitoring? e Date: Reading Data Gross Time Net Thune Depth to Water Net Drop 1 2/14/2013 [Pre t" D •r 2 '0;!'U 3 aii)� 30 `` 1125u (,14 5 s O G�D�ie 6 Il a n° -71i2" ,fib YEKUUI IIUH KATE (minuiesrnch) PERC HOLE DIAMETER '7n TEST RUN BETWEEN_ FT AND ? Fr COMMENTS Perc Cavity was presoaked PERFORMED BY: A• Harala I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Performed For: Ray Hickel Legal Description: 1 �r CSM Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.d.anchorage.ak.us (907) 343-7904 Soils Log - Percolation Test Date Perf Timber Trail Subdivision, Lot Township, Range, Section:. 13-I I M e4I d µ^ 14- J 15- 17 EMUR Reading Date �j WAS GROUND WATER 9 -ENCOUNTERED? Depth to Water /o ENCOUNTERED? 1 2/14/2013 5 10- 7• A ' I f� IF YES, AT WHAT DEPTH? t 2 y (ri Depth to Water After P 11- .m6" Monitoring? E 12- Date: 13-I I M e4I d µ^ 14- J 15- 17 EMUR Reading Date Gross Time Net Time Depth to Water Net Drop 1 2/14/2013 ` f'♦1%i 7• A 2 10141 MI .m6" 3 lotSZ 1,1%`� 4 II' 7-v 3o mob 'Q,�f 5 trti -7,Iv 6 t s3 Mt f g rcRuuu.nun HattyrI (mmutesfinch) PERO HOLE DIAMETER "'�•• TEST RUN BETWEEN —4--t5r FT AND 9• D FT COMMENTS Pere Cavity was presoaked PERFORMED BY: A. Harala I - CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: On-Site Water System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141501 Tax Code Number: 01710155000 Work Type: Well Initial Permit Effective Dates: November 12, 2014 to November 12, 2015 Design Engineer: ANDERSON ENGINEERING Subdivision: TIMBER TRAIL Site Legal Address: TIMBER TRAIL TR lA G:3037 Owner/Address: RAPTOR PROPERTIES LLC 5725 YUKON CHARLIE LOOP ANCHORAGE AK 995020000 Department Site Mailing Address: 14100 GOLDEN VIEW DR, Anchorage Lot Size in Sq Ft: 334105 Total Bedrooms: 4 This permit is for the construction of: N Disposal Field N SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Aecial Provisions: EN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS N DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL PPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. Received By: Issued By: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parce' I.D. 017-101'55 'RUSH!D' Propertyowner(s) Raptor Properties LLC [ ,phone 830-2052 Mailing address 5725 Yukon Chadie Loop Anchorage, AK 99502 Site address 14100 Golden View Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Timber Trail, Tract lA (Lot 2) Legal description (Township, Range & Section) Lot Size 49,932 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: (~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: Initial [] Upgrade [] NOV l ~ 2014 TYPE OF DWELLING: Single Family (SF) [] (w/wo ADU) Duplex (D) [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES.A VARIANCE / WAIVER.REQuEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. r ~I , RUSH! j (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Num bet: Waiver No. Permit App_9-1-12.doc November 11, 2014 Building Safety Division On Site Water and Wastewater Program . 4700 Elmore Street Anchorage, AK 99507 Attention: On Site Services Engineer Su~e~: Raptors Knoll Subdivision Proposed Lot 2 Aquifer Study Well Permit Dear Jay: Raptors Knoll Subdivision is composed of 6 Lots and is located off of East 142nd Avenue near Goldenview Drive in Anchorage. It is surrounded bY developed lots served by private wells and on site septic systems. The lots proposed for the subdivision are in excess of 40,000 square feet and are proposed to have on site wells and septic systems. Three wells are proposed for placement in the subdivision on proposed Lots 2, 5 and 6. The wells will be placed at sites which will represent standard locations relative to septic system sites and home sites on typical lots in the subdivision. Each well will be pumped in accordance with AMC 15.55.060F1 to establish the sustained yield as determined by the well driller.. Water quality testing from each well will be accomplished in accordance with AMC 15.55.060F2. A formal report including sustained yield results for each well will be submitted once all data is gathered and analyzed. A permit application is attached for placement of the well on Lot 2 in the subdivision. The location of the well and the proposed reserve area for the septic system on the lot are shown on the attached Site Plan and will not impact adjacent properties. If the well and proposed septic system is constructed in accordance with our design the following statements apply: The well, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The well, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. Lot 2, Raptors Knoll Subdivision November 11,2014 Page 2 The well, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The well, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments S 89'55'50"E 660.71' 550. 6' 20' TENL ESMT. 310.55' 10' UTIL LOT 5 ~ LOT 4 (55.2~5 S.r.) / /~ Proposed (54,625 S.F.) / LOT 5 Well -.~ 54,075 $.F'. LOT 2 49,932 S.F. (54.612 N 89'57'33"[ 280.16' , 0 60 120 SCALE 1" = 60' [,,.~- ............ -..~, ,..~, ..-~.> TEST WELL PLAN LOT 1 44,517 S,F, (58,966 N 00'05'17"W 0 g m 156.02' I i tld1 !l Tf.,� IP.I `62016 ® Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-79044'' Certificate of On -Site Systems Approval Parcel I.D. 417-101-59 Expiration Date: 1. GENERAL INFORMATION Complete legal description Raptors Knoll, Lot 2 Location (site address) 14135 Raptor's Knoll Cir. Current Property owner(s) Spine[] Homes, Inc. Day phone Mailing address 1900 W Northern Lights Blvd. #200 Anchorage, AK 99517 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well lx Individual Q Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNadance request for:, Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment / Date of Payment Receipt Number O/1 6-"n Receipt Number COSA# 65V 6 1 b62, Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply . and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, 1 attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Alk. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE System #1 Approved for (o bedrooms System #2 Approved for bedrooms Disapproved Date 1/5/2016 Conditional approval for bedrooms, with the following stipulations: By: "I 1W t Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSAblueshe t (-- ., c If more than I septic system is on the lot: COSA Checklist # 1 of Structure served by this system 1 Certificate of On -Site Systems, Approval Checklist Legal Description: Raptor's Knoll, Lot 2 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 11/29/2014 Sanitary seal (YIN) Y Total depth 296 ft. Cased to 244 ft. Parcel ID: 017-101-59 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 11/29/2014 N/A Static water level IlRkrrown /z"5 ft. N/A ft. Well production 10+ 9 -P.M. N/A 9 P.m WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate 01 07 mg/L Arsenic ND ug/L Date of sample: 12/22/2015 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 2,000 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Date of pumping New Depression over tank (Y/N) N Pumper N/A Collected -by: PES Date installed 8/22/2015 Cleanouts (YIN) Y High water alarm (Y/N) N C. ABSORPTION FIELD DATA Date installed 8/22/2015 Soil rating (g.p.d./ftz or f?/bdrm) 0.8 GPD/SF System type Deep Trench Length 73 _ft. Width 2.5 ft. Gravel below pipe 8.5 ft. Total depth 13 ft. Eff. absorption area 1,241 fe Monitoring tube Y Depression over field N Date of adequacy tesp New Results (Pass/Fail) Pass For 6 bedrooms Fluid depth in absorption field before test New in.. Water added New gal. New depth New in. Elapsed Time: New min. Final fluid depth New in. Absorption rate >= 900+ g.p,d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) No If yes, give date D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons _ in. "Pump off' level at Cycles tested _ Manhole/Access (Y/N) in. High,water alarm level at Meets alarm & circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer /septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Water main 10+ Water service line 10+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION / certify that .i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven Pannone Date 1/5/2015 COSA canary sheet_2-6-15.doc Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 10+ in.