Permit Effective Dates: July '17, 2015
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box '196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to July 16, 2016
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: KASILOF HILLS
Site Legal Address: KASILOF HILLS BLK 8 LT '11 G:2541
Owner/Address: VECERA NEZ ALICE TRUST
VECERA NEZ ALICE/TRUSTEE 3000 DAWSON ST ANCHORAGE AK 995033842
Site Mailing Address: '10200 Stroganof DR, Anchorage
Lot Size in Sq Ft: 46'194
Total Bedrooms: 6
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Ddnking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October '15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions:
The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation
test. The Engineer needs to do an additional percolation test prior to the construction of the septic
field. Please submit stamped and signed results with the As-built Inspection Report. If the results
require a design change, construction of the system will stop pending Qn-Site review and
approVal. AMC '15.65.060.B.3
./
Municipality of Anchorage
P.O. Box '196650 · 4700 Elmore Road
Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:l/www.muni.or;llO nsite
Develor)ment Services Division
On-Site Water and Wastewater Proflram
tmen~
VARIANCE/WAIVER REVIEW ****
Waiven~: OSVt5t084 COSA#: Permit: OSP15t174
PID#: 015-132-04
Legal Description: Kasilof Hills Block 8 Lot 1t
Engineer: Pannone En¢fineerinQ SerVices
Applicant: Alice Vecera
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the excessive slope has been approved. The approved separation distance is 30.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposai system will require all separation distances be met or another
approval from this department.
[] The affected adjacent .property owner(s) have been given a 7 day notice regarding this
waiver.
[] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacem property.
[] Adjacent properties are not affected by/his waiver.
Waiver is Granted: X Waiver is not Granted:
Date: 7v~'7~'- Approved by:, _/~..~_/~_.~_~'.~r/~, ~,~_.--
· . ....(' 'd... .... ' - .~m. ~f Reviewer/ -
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-132-04
Property owner(s) Alice Vecera
Mailing address 3000 Dawson St., Anchorage, AK 99503
Day phone
Site address Stroganof Drive
Legal description (Sub'd. Block & Lot) Kasilor Hills, Block 8, Lot 11
Legal description (Township, Range & Section)
Lot Size 46,194 .Sq. Ft. Number of Bedrooms 6
APPLICATION IS FOR:
([~ all that apply)
Absorption Fierd []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
TYPE OF DWELLING:
Singre Family (SF) '
(w/wo ADU)
Duplex (D)
Multiple Dwerlings
(SF and/or D
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I Certify that the above information is correct. I further Certif~ that this is in accordance with
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No. O'D¢ t5
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_~- .. ,_.~c.
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-maih steve~, panengak.com
June 4, 2015
Subject:
Ka~ilof Hills, Block 8, Lot 11
Well and Septic System Permit Request
Design Narrative
This is a design narrative for a permit to install a new well and septic system to be issued for this property. The
proposed Systems will serve a proposed six (6) bedroom house. Currently the lot is undeveloped. The proposed
system will utilize a 2000g septic tank with a conventional drain field. The surrounding developed lots are served by
private wells. There are no wells on surrounding lots within 100 feet of this system and there are no septic systems
installed on the surrounding lots within 100 feet of the proposed well.
Soils. One test hole was performed in the vicinity of this system by Pannone Engineering Services in May of 2015,
and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 14.0'
below the surface in the test hole monitor tube in May of 2015. Bedrock was not encountered in the test hole. It
is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of
1.2 gallons/day/square feet should be used for a conventional wastewater system in the a rea of these test holes.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The
proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches.
4. Topography: The existing topography slopes from the east to the west at approximately 20% in the area
of the septic system. There are no steep slopes within 50' of the proposed primary drain field. The proposed
primary drain field will maintain 50' separation all steep slopes. The proposed reserve drain field will be located
approximately 38' east of the road cut slope. A waiver for the reserve field will be applied for when lhe system is
upgreaded.
5. Drawing Markings:The Drawings are marked "For MoA Review Only". When writen notification that the review
is complete and that there are no further comments is received from MoA OmSite Department, the note will be
removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There are no
surrounding wells within 100 feet of the proposed septic location or septics within 100 feet of the proposed well
location.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
DESIGN PARAMETERS ax ,' / ~/ / I/ ?o,-,~.~ .... ,~,~'J// /
PRIMARY SEPTIC SYSTEM ~ WL4LL (~.__lx . ,? /, ~u- ....... ~>~] /~ /
NO. BEDROOM: 6 (900 gpd) ~ ~ ,~~
TANK SIZE: 2000 ~. ~'~ ) T~'
PERC RATE: 1 MP[ ~b~ x / ~ / /. /~/ ~/~ /TH TEST HOLE
a~A ~aD: sS0 SE ~> ~ ~ ~ ~, /' A~ 'xt" ~ N. ~3(p) P~O~OS~D
SYS ~PE' DEEP TRENCH 6'ED ~ /~ ~ / / /A '~ k ~ . .
· - _ · ' / ~ ,~ ~ (E) EXISTING
USE: : / , / '
TOTAL AREA: 7~6 SF / , / .~-- ,' ~
. ~ , '~ - / ,' .f / ' ' ~ :' , ' SPD GALLONS PER DAY
N X ~. , I ~ '--. ~/' / Z '
~ SE~,c A~E~ (O / .,,~/ ; /' / ' ' ' J I ' I
,,~~ '~ ' I ~ , ~ I I
~ /~ ~z ,' / f' ', ' ' ' ~ SEPTIC AREA (E)~- L
, ~ i~ ~ NI ' , . /
~ / / / ~ , r~ : LOT11: r
~ / '~ ~W~
6ZLFx 2.5'Wx 6.0'EDx 80'TD~ ~ N' ,/
PROVIDE 3' OF COVER OR RGID INSULATION .; ~20' . ~ '
> " ~ ' / , /
~ 20009 SEPTIC TANK (P) ~ ,, '
~ ~ WITH DOUBLE CLEAN OUT 'x ',, I
.' 3 , ~ , ,~ ~ ~ .. ~ ' .
o ,~ . , , ,, ,, /
%'PECIAL PROVSIONS' TO SPEC'IFICATIONS'/~_ '
~ ~~----: - ~ , ' . ', ' x · ,
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED N THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR'COMPONENT PARTS AND MATERIALS USED IN CONSTRUC?ION OF
~ ON-SITE WASTEWATER DISPOSAL SYSTEMS
2. SCOPE OF WORK: INSTALL NEW 2000g SEPTIC TANK AND SOIL ABSORPT ON SYSTEM INSTALL WELL.
3 GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 14.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL
- TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 14.0 FEET BELOW
EXISTING GRADE NOT[~ THE ENGINEER IMMEDIATELY.
NOTES. P~O~ ENG ~C, L~
FOR CONSTRUCT~ON P.O. BOX 100217 ANCHORAGE, AK 99510 ...... '
PHONE (907) 272-8218 FAX (907) 272-8211 ': P~.o. NO
KASILOF HILLS, BLOCK 8, LOT 11
ALICE VECCERA
C.G. SPINELL HOMES ~.. CE 8149 ,~ PERMIT NO.
STROGANOF DRIVE ~I " .... "
PLAN ANCHORAGE, AK 99516 i~O~{s~ Sheet
TESTHOLEI
ORGANICS/
OR/GL
ORGANIC SILTS
GM/ SILTY GRAVEL
SM AND SAND
BOH
DATE PERFORMED: 5/15/15
SLOPE
SOILS LOG - PERCOLATION TEST
X
TH
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH? -DRY
DEPTH TO WATER AFTER
MONITORING? -DRY
DATE: 5/28/15
6 BR
HOUSE
SLOPE
TH
X
WATER
CLOCK
READING DATE NET T~ME LEVEL NET DROP
TiME
READING
I 5/15/15 10:55 _._ 2.30 ___
2 10:45:45 ;.75 MIN(DRY 8.30 6.00
3 10:46 --- 2.30 ' ---
4 10:51:54 5.9 MIN(DRY) 8.30 6.00
5 10:52 ... 2.30 ...
6 10:58:01 6 k41N(ORY) 8.30 6.00
PEROLATION RATE 1 (min/inch) PERC HOLE DIAMETER 6 inches
tEST RUN BETWEEN 3 FT AND 4 FT
COMMENTS: Test hole excavated by POMRANING EXCAVATION. Prec hole was presoaked.
Test run for at least one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pan~0ne, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
,OTES: PANNONE ENG SVC, LLC
FOR CONSTRUCTION P,O, BOX 102954 ANCHORAGE, AK 99510
7/8/2015
PHONE (907) 272-8218 FAX (907) 272-8211 ~... ~..~
N *.' 49 ~ ".* ~ NTS
KASILOF HILLS, BLOCK 8, LOT 11 ~_~.~~ ~I.D. NO
ALICE VECCERA~"~";'"'"~~¢~EKo~ om-~32-o4
C.O. SPINELL HOMES r¢~'. CE 8149 ..~ ~ERM*T NO
f~.. , .~ 3SP151174
STROGANOF DRIVE -~(~¢~'. ..... ~ Sheet
SOILS LOG ANCHORAGE, AK 99516
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve~panenRak corn
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99519
July 15, 2015
Subject:
KasilofHills, Block 8, Lot 11
Reserve Absorption Field to Slope
Ladies and Gentlemen:
1. Slope Waiver: I request a waiver to the code requiring a minimum distance to a slope
over 25% of fifty feet (50') to a distance of thirty feet (30'). Due to topographical constraints on
the lot, it is not possible to achieve the required separation distance. As shown in the attached
section any effluent moving at a 4:1 slope beginning 2.5' above the pipe invert of the reserve
field at the lower side of the field will not daylight within 38.5' of the system. This is extremely
unlikely though du~ to the well percolating nature of the soil. The primary system will be
located 44.6' from the slope, and an infiltration line at 4:1 will not daylight within 50' of the field.
The proposed installation will not affect the future development of the surrounding or existing
lots. If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
~.....~....~.-~....~.~, ..~....~
Steven R. P~one, P.E.
Owner/Cidl Engine~
Attac~ents:
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 1/2 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
NOT~S: PANNONE ENG SVC, LLC
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 995~0 ~."
SLOP~ WArVER SECTaON PHONE (~07) 272-S21a tax (007) 272-~2~ ~..
KASILOF HILLS, BLOCK 8, ~OT 11 . ~~~:~..~~ 015-132-04
AUCE VECCERA ~ · e . o o e
C.O. SPINELL HOMES i~'. CE
PERMIT
DESIGN DETAILS ANCHORAGE, AK 99516
OF