Loading...
HomeMy WebLinkAboutRAPTORS KNOLL LT 5Raptors Knolls Lot 5 #017-101-62 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP161023 PID Number: 017-101-62 Dwelling: X Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: W New ❑ Upgrade Name: Harding Homes of Alaska, Inc. ABSORPTION FIELD *Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 5771 Heritage Heights Drive Anchorage, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 350-1860 6 1.2 GPD/SF 11.6 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.6 Ft. Gravel depth beneath pipe 8 Ft. Subdivision Block Lot Raptors Knoll 5 Fill added above original grade 0-,5 Ft. Gravel length 50 FL Township Range Section Gravel width 3 FL Beds: Number of Lines Distance between lines FL SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 800 Ft' One Ft. Well >100' >100' >100' NQ >25' TANK O Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 2,000 Gal. Surface Water >100' >100' >100' NA Material Steel Number of compartments Two Lot Line >5' 10' >5' NA NA Foundation >5j' >10' >5' NA LIFT STATION Manufacturer Capacity Gal. Curtain Drain None Noted Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to drainfeld D3034 Installer Harding Homes Grainfield D3034 CO/MT Q 034 Inspector W. Roberts BENCHMARK (Assumed elevation) 100.0 It Inspection1" 5/18/16 5/19/16 Location and description 2•a dates: 3°' 5/19/16 41" Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL ® P��OF 44°444Ao 1,+- '•.� Conditional Approval: Date ®G� I® non m 0 MICANDERSON•,' 4 s :• CE - 4331 _ o L •�. V� e AAa4f0 �J pROFEssioA�OO� 0S Approved adt Date Sao"voo Inspection Report _9-1-12.doc Permit No.: OSP161023 0 0 a 3 0 0 0 Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report PID No. 017-101-62 S 89"55'50"E 350.16' 20' TRAIL ESMT. 1 I ------------------------ ------------- 23 T & -ESMT. ------------------- E. ----------------------- 10' UTIL ESMT.-------------------------I ----------------------- --------------------------------I- A B 5' TRAIL ESMT S z2.a 25.7• 1 S2 zzs 40.6' 1 C5 48.8' 53.7' 1 C6 36.5' 72.8' m1 48.9 547 TH10 I m Alternate I n LEGEND S1 - Septic Vent TH - Test Hole M1 - Monitor Tube C5 - Clean Out 2CO - Double Clean Out FCO - Foundation Clean r 49th MICHAEL E. ANDERSON VA SCALE 1 " = 40' 30' SLOPE & DRAINAGE 10' U.G. RIGHT OF WAY ESM -ft' ` RAPTORS KNOLL (2014-043192-0)®E Weling CIRCLE Site — -I- Six Bedroom o� I N I C6 A Home 1 TH 1 1 c��i I o I 9 s3• �3s6•• S 1 S2 FCO I z I I 33) 2Co TH9 ._ s7• / M1 I Out C5,,- 5/RAPTORS RAPTORS KNOLL / I LOT 5 / - I ®E Weling 54,075 S. F. q PLAN A S I BUILT so �' — Existing .50.00• Well SCALE 1 " = 40' 30' SLOPE & DRAINAGE 10' U.G. RIGHT OF WAY ESM -ft' ` RAPTORS KNOLL (2014-043192-0)®E Weling CIRCLE Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP161023 PID No. 017-101-62 1.7 98.6 U U) / cn 2CO 2,000 Gallon Septic Tank M r _LO 96.7 OG and Finished Grade 2" Insulation & Geotextile Fabric _ 93 1 Drainfield Rock 93.1 85.1 77.7 No Groundwater 50' (Trench Length) 5-15-13 "Xxgo0 OF '.. .4.,q •��OP�E ..Y .•. 49th �..... ............... i.�s-� PROFILE AS -BUILT ��MICHAEL E. NO.CEQg3BRSON •��1'f' No Scale No ......•�%N`• a. DATE MUNICIPALITY OF ANCHORAGE GROSS TIME NET TIME WATER DEVELOPMENT SERVICES DEPARTMENT ��pP-�E 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 9:18 `; 0.75" SOILS LOG - PERCOLATION TEST 49th 0 i • . 9:48 30 7.25" .........................................:... MICHAEL E. ANDERSON ; j LEGAL DESCRIPTION: LOT 5, RAPTORS KNOLL SUBDIVISION ♦sr'••.• NO. CE -4381 PERFORMED FOR: HARDING HOMES INC.O,;p4O..ESSl����� 0.50" K....L�... DATE: 5/18/16 PROJECT No.: 10:10 rrrrr���� PARCELID#: TECHNICIAN: W. ROBERTS orossfonalE ineenStamp: DEPTII TEST HOLE l 1 10:11 (feet) OB/OG SLOPE SITE PLAN 2 a SILTY GRAVEL 3 WITH SAND GM 4 a a 5 a N o SEE SITE PLAN 6 7 8 9 1 O WAS GROUND WATER ENCOUNTERED'? No IF YES @ WHAT DEPTH? S 2% DEPTH OF WATER AF'1'EI(MONITORINC: O 11 DATE OF MONITORING. P E 12 DEPTH To 13 (MINUTES) (MINUTES) (INCHES) (INCHES) 14 15 16 17 18 BOH @ 18' 19 6 10:41 30 7.13" 6.38" 20 PERCOLATION RATE: 4.7 (MIN/INCH) PERC. HOLE DIA. 611 (INCHES) TEST RUN BETWEEN: 6.0 FT. and 7.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/16/16 DATE READING GROSS TIME NET TIME WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: 6/7 1 9:18 0.75" 2 9:48 30 7.25" 6.50" 3 9:50 0.50" 4 10:10 30 6.88" 6.38" 5 10:11 0.75" 07/02/2016 21:11 907-345-0202 ALPINE DRILLING Alpine Drilling & Enterprises Well Log PAGE 01/03 Permit Number: #SW141499 Date of Issue: 11-10-14 Parcel Identification Number: 01710155000 Date Started: 11-13-14 Date Completed: 11-14-14 Is well located at approved permit location? x Yes ❑ No Legal Description; Timber Trail Lot 5 Property Owner Name & Address: Raptor Properties LLC 5725 Yukon Charlie Loop Anchorage, Alaska 99502 Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) From To Method of Drilling x air rotary ❑ cable tool Casing type: steel Stick-up 0 2 Wall Thickness: .250 inches silt gravelly cobbly silt 2 9 9 38 Diameter: 6 inches Depth: 235 feet Liner Type: 4 Diameter: inches Depth: feet sandy silt 38 57 Casing stickup above ground: 2 feet Static water level (from ground level): 148 feet cobbly silty gravel 57 65 silt 65 76 Pumping level: 230 feet after gravelly cobbly silt 76 155 2 hours pumping 20+ gpm Recovery Rate: Q gpm cobbly gravel 155 163 Method of Testing: Aar li t sandy silt 163 173 Well Intake Opening Type.- ype:gravelly gravellysilt 173 228 x Open End ❑ Open Hole silty water sand & gravel 228 235 ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite Volume: Zbes Depth: Start 0 feet Stopped ? feet Pump: Intake Depth feet Pump size — hp Brand Name Well Disinfected Upon Completion? x Yes ❑ No WATER QUALITY TESTM Method of Disinfection: chlorine tablets Cditm Neu C MMM Comments: Mrstm q Af> lic 0) UO& Well Driller; Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 Oct.21, 2016 8:28AM Development Services Department Building Sqfety bivision On -Site Water et Wastewpter Program 4700 Elmore Road P,O, Bolt 196650 Mark Begich Anchorage, AK 99507 Mayor w ,munixrg/onsite (907)943-7904 P�utmp Installation Log f Well Drilling Permit Number: SW ) J 4 1411 YL1 1 Date of Issue: Parcel IdenfiBcation Number: ®1 14v 16 6000 Pyr gni 6(. r Pump Installation Date: L1I 1201 `91 ( Pump Intake Depth Below ITop of Well Casing! c�,qA feet Pump Manufacturer's Name: Pump Model: 5 I Pump Size I A hp '' \\ Pitless Adapter Burial Depth: O� feet Pltless Adapter Manufacturer's Name: I Pitless Adapter Installer: jV Wes Disinfected Upon Completion? Yes ❑ No Method Comments; Please save for your engineer. This is needed for your COSA. Pump Installer Name: .Aarow PMP & Well Sttn+lee P.O. Ux 110496 AmcharW, AK %511 -DG" NOU No.4206 P. 1 Attention: Tho pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Wockenfuss, Deborah M. From: Frost, Jack L. Sent: Monday, October 24, 2016 11:03 AM To: Wockenfuss, Deborah M.; Packard, Michael D.; McGee, Lynn M. Cc: Snelson, John W., Walters, Michael S. Subject: Letter of Non -Objection not required for Lot 5, Raptor's Knoll Subdivision, commonly known as 14070 Raptors Knoll Circle, Anchorage, Alaska; 017-101-62-000 Attachments: Raptor's Knoll, Lot 5.JPG Good mornin-, This e-mail is to document for the purposes of issuing a Certificate of Occupancy; Right of Way Enforcement/Zoning Plan Review will not require a Letter of Non -Objection for the well head located in the drainage and slope easement or CEA UG easement adjoining Raptors Knoll Circle for Lot 5, Raptors Knoll, commonly known as 14070 Raptors Knoll Circle. The well was legally installed per On -Site Permit OSP161023, issued February 16, 2016. A photograph of the subject property is attached. Regards. 1 .lack L. Frost Chief, Code Enforcement 907.343.8033 (Main) 907.727.7632 (Cell) On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161023 Tax Code Number: 01710162000 Work Type: Welseptic Initial Permit Effective Dates: February 16, 2016 to February 15, 2017 Design Engineer: ANDERSON ENGINEERING Subdivision: RAPTORS KNOLL Site Legal Address: RAPTORS KNOLL LT 5 G:3037 Owner/Address: EGELAND GREGORY & TIFFANY 12090 LOWER HERITAGE CIR ANCHORAGE AK 995160000 Site Mailing Address: 14070 RAPTORS KNOLL CIR, Anchorage Lot Size in Sq Ft: 54075 Total Bedrooms: 6 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. The entire subsurface disposal field is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.8.3 2. The Engineer needs to do an additional test hole for the alternate site prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. 3. Prior to inspection report approval, the pump install log and water samples are to be submitted for review. 4. An MOA Encroachment Permit is required for the well located in the Slope and Drainage Easement prior to inspection report approval Received Issued By: �/N� Date: MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-101-62 Property owner(s) Harding Homes of Alaska Day phone 350-11860 Mailing address 5771 Heritage Drive Anchorage, AK 99516 Site address 14070 Raptors Knoll Circle Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Raptors Knoll, Lot 5 Legal description (Township, Range & Section) Lot Size 54,075 Sq, Ft. Number of Bedrooms Six (6) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Q Initial R Single Family (SF) El Septic Tank Q (w/wo ADU) Upgrade 11Duplex ❑ (D} ElRenewalTank Renewal El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Absorption Trench to Slope Waiver Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. owner or Permit/Rush Fees: -5-C,94 ZIWaiver Fees: Z I S Date of Payment: ZI S 116 Date of Payment: Receipt Number: g Y �R G Receipt Number: Permit No. OSP f6 /0 Z 3 Waiver No. 0 SV(ti /DO 6 Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX February 5, 2016 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 5, Raptors Knoll Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 5, Raptors Knoll Subdivision intends to construct a new six -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the existing well and proposed septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench indicate silty gravel with sand (GM). We are assuming the soils at the alternate site are the same and subsurface soils throughout the subdivision have been consistent. The percolation rate of the soil at the test holes was determined to be 1 to 5 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 2,000 -gallon septic tank and an oversized 50' long by 3' wide by 8' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 11'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. We are requesting a condition to the permit requiring additional test holes and percolation tests to insure the continuity of soils for the alternate site and other areas of the absorption system that do Lot 5, Raptors Knoll Subdivision February 5, 2016 Page Two not fall within the 30' radius of Test Hole No. 9. All subsurface soils in the subdivision have been found to be consistent. The ground surface on the lot in the area of the septic system slopes to the southwest at a shallow grade with some cross sloping from the east. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, n Michael E. Anderson, P.E. Attachments th MICHAEL E ANDERSON -0"O o Vl ���•519 ",s��1 00<rl �•a� N AV I a N' N a N N 00'05'17"W 45.00' i allo Le h i>� 0 -n nom (DZ x - %`mm, :S n% coQ3�� �N�� i I 92 0 CL z• o o m rt I I I cn C: 0 I l I o CA O Pw l l I z w- �^ — a= " / I I I N D O a�`' oo I I _ r C W _ o T Q — � I c ��� �� > ^� Z r fV O m x� � rn cn \ / T� // IrlLn I N CA / n x w riE O 47 N U O I I 6i A_ z \ c° < O /w z N m ° � m = C I I Ln OD LO i� 3 ° " � Un C/) I I I CD0 �p 0 l m �S� N F— > D o I u I I I ` I A m fTl O—— r N r N 08 0 _ r =� x 89'33 E 22 .39' L _ �U --- 0i LOT 5, RAPTORS KNOLL SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Six Bedroom Home Perc. Rate: 15 Min./Inch Application Rate: 1.2 GPD/SF Deep Trench System 2,000 Gallon Septic Tank 8' Drainfield Rock 6 Bedrooms X 150 GPD/.1.2 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/16 SF/LF = 46.875 LF Trench Length THEREFORE: Construct a 50' Long x 3' Wide x 8' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Natural Backfill 2'6" Geotextile Fabric 6" Q 4' Perforated PVC (Holes Down) M 3' Drainfield Rock TYPICAL DEEP TRENCH 0E1-%T1nKl (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. ----------- _.---- ------ -- - Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 _ www.ci.anchoraae.akus (907) 343-7904 Soils Log - Percolation Test Performed For. Ray Hickel Performed: reD u,.&Uia Legal Description: Timber Trail Subdivision, Lot 5 Township, Range, Section: 4 Date Gross Time Depth Depth to Water Net Drop (Feet) p� .1- 1 o Mldlh O 3- 4- 3-4 5- n /taZS ?.7tA t 6.Dfo - 5-6 7 7 l y(� 8- 7-8 9- d 7 3e IV. 17% 10- 9-10 11- tt 'T W 10.14" Site Plan WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? t Depth to Water After D Monitoring? /VOL t E Date: 5-11;"-(3 Reading Date Gross Time Net Time Depth to Water Net Drop 1-2 2115!2013111,14/11-*I� 1 o Mldlh 7.3 %i•o$" 3-4 I :3 tI�LC{,pt n /taZS ?.7tA t 6.Dfo Q r7 5-6 l 7 `Ei. la.l• 147- 7-8 d 7 3e IV. 17% ,19" 9-10 2 Z3 t2 3: tt 'T W 10.14" I.Sl ' 11-12 It '1.3811a•Db '2�`�" PERCOLATION RATE (MbAeerarh) PERC HOLE DIAMETER 9y �• TEST RUN BETWEEN FT AND__�; aF-r COMMENTS Pero Cavity was presoaked PERFORMED BY: A. Harala I T/U%uJfr.GQ^ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10'-1`1-1)( Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchoraoe.ak.us (907) 343-7904 Soils Log - Percolation Test Performed for. Ray Hicks] Date Z-4 -•/ L Legal Description: Timber Trail Subdivision, Lot 5 Township, Range, Section: 0 eVv 69 67t me,' �t)� Site Plan WAS GROUND WATER ENCOUNTERED? 5 IF YES, AT WHAT DEPTH? L Depth to Water After D Monitoring? No IJ Dale: `S_t5 i.3 Reading Date Gross Time Net Time++.' to Water Net Drop 1-2 2/15/2013 (�'1$jl(�''I�•' h'(IIWi ,rDepth �{.G3 Ila,6" 3-4 N •�t9 (2:0� u ,y o r. 5-6 (T. (I Avv t' fflO.rr 7-8 (Zi2 7i! tr `F�iL�(ori8 .SI 9-10 11-12 rtKUULA I IVN KA It 'liV, (mlwemtrt) PERC HOLE DIAMETER {j TEST RUN BETWEEN �,'J FT AND �Cp Fr COMMENTS Perc Cavity was presoaked —r—�— PERFORMED BY: A. Harala I " r—tld- CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10-17-IY February 6, 2016 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 5, Raptors Knoll Subdivision Absorption Trench to Slope Waiver Dear Onsite Services Engineer: The subject property is relatively flat except for a steep slope near the southwest property line. We have located an area with acceptable soils for the absorption trench upgrade, but it is located 30' from a break in grade greater than 25%. The end of the alternate site is 37' from the break. We are therefore applying for a waiver allowing placement of the absorption trench and the alternate site at the designated locations. The attached drawing shows the absorption trenches in relation to the slope. The imaginary 25% slope when extended downward from 2' above the distribution line does not daylight for the primary trench less than 50' from the sidewall and 45' for the alternate site. We therefore request a waiver be issued allowing placement of the new absorption trench within 30' of a slope greater than 25%. We also request a waiver allowing the alternate trench to be 37' from the slope greater than 25%. Sincerely, Michael E. Anderson, P.E. MICHAEL E. ANDERSON No. CE -4381 a 0 fi a e m D ;ET ® MVlunicipaUty of Anchorage . On -Site Water and Wastewater Program Y „ <'r r (907) 343-7904 r_¢, i Certificate of On -Site Systems Approval Parcel I.D. 017-101-62 Expiration Date: i Z 4 % 7 1. GENERAL INFORMATION Complete legal description Raptors Knoll, Lot 5 Location (site address) 14070 Raptors Knoll Circle Anchorage, AK Current Property owner(s) Harding Homes of Alaska, Inc. Day phone 350-1860 Mailing address 5771 Heritage Heights Drive Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS:''Six 4. TYPE OF WATER SUPPLY;,'., Individual Well Individual Water Storage' ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual Holding Tank ❑ Community ❑ Public Sewer ❑ Waiv&Nariance request for: Distance: - pnl r i COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 6 % sy f ^r ��_ Waiver Fee $ Date of Payment /0 — 2/-- 46 Receipt Number Q� COSA# Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name _Michael E. Anderson, P.E. 6. DSD SIGNATURE Phone 522-7773 Date 10/21/tq �VOF <w. 491H K System #1 Approved for bedrooms?`,+JICH''a e aNOEeso+ U C� �3SI o System #2 Approved for bedroomsYf pF°,, �' Zr-�(:•°���;� Disapproved s aR�pc ^S`IO�mer Conditional approval for bedrooms, with the following stipulations: By: Lz� Original Certificate Date: %0 Z The Municipality of Anchora/ Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f 1: e If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system - Certificate of ®n -Site Systems Approval Checklist Legal Description Raptors Knoll, Lot 5 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 11-14-14 _ Sanitary seal (Y/N) Y Total depth 235 ft. Cased to 235 ft. FROM WELL LOG Date of test 11-14-14 Static water level 148 ft. Well production 20 g.p.m. WATER SAMPLE RESULTS: Parcel ID: 017-101-62 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >18 in. AT INSPECTION ft. Coliform 0* colonies/100 mL Nitrate •902 mg/L Arsenic N/D ug/L Date of sample: 9/28/16 Collected by: And. Engineering *Retest 10/11/16 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 2,000_ gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Date of pumping New Pumper Construction C. ABSORPTION FIELD DATA Date installed 5/18/16 Cleanouts (Y/N) Y High water alarm (Y/N) N Date installed 5/19/16 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD System type Deep Trench Length 50 ft. Width 3 ft. Gravel below pipe 8 ft. Total depth 11,6 ft. Eff. absorption area 800 ft2 Monitoring tube Y Depression over field N Date of adequacy test New. Const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed _ "Pump on" level at Datum Size in gallons in. "Pump off" level at Cycles tested _ E. SEPARATION DISTANCES WELL ON LOT TO: Manhole/Access(Y/N) in. High water alarm level at Meets alarm & circuit requirements? > 100' Septic tank/lift station on lot On adjacent lots Absorption field on lot >100' On adjacent lots >100' Public sewer main >75 Public sewer manhole/cleanout >100' Sewer /septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >51 Property line >51 Water main >10, Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10, Building foundation >10' Water Service line >10' Surface water >100' Curtain drain Nolle Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 10/21/16 COSA brown sheet 10-10-12.doc Absorption field >51 Surface water >100' Water main >10' Driveway, parking/vehicle storage >10, e®domo®maen . :MICHAEL E. DER OL�urv;�'y 41 s CE -4331 :� m dddr�9fo to tPRO FESS Q®`3,®®d�y�A in. PLAT NO. 2014-128 RAPTORS KNOLL SUBDIVISION LOT 5 54,075 S.F. S 89°55'50"E 350.16' .11 20' TRAIL ESMT. 23' T. do E. ESMT. o ------- - ------ - - _- 10'UTIL.ESMT._ I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - +1 BUILDING DETAIL SCALE: I"=20' GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 2000 E. DOWLING RD., SUITE 6 ANCHORAGE, ALASKA 99507 PHONE 248-5454 GRID SW3037 F.B. 16-03 DATE 9/23/2016 JOB NO. RAPTORS �� G 5' TRAIL ESMT.—f' I H SQ n. I ti M M 30' SLOPE & DRAINAGE ESMT. 10' U.G. RIGHT OF WAY ESMT (2014-043192-0) I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. R IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE RAPTORS KNOLL CIRCLE +*%SUN** OO POF1� te........ A� I s �� 49THAr y e ...........T. , ......... .........1 '. Jeffery A. Gastaldi g LS -6091 A AV m �ap .....•• aid O °ressiona\ \- o• 1 11=40'