HomeMy WebLinkAboutROSEBERRY HIGHLANDS LT 8Ros berry Highland Lot 8 #0§0-31 §-66 On -Site Wastewater Disposal System Permit Permit Number: OSP161041 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907)343-7904 Tax Code Number: 05031566000 Work Type: Septic Initial Permit Effective Dates: March 24, 2016 to March 24, 2017 Design Engineer: NORTH RIM ENGINEERING Subdivision: ROSEBERRY HIGHLANDS Site Legal Address: ROSEBERRY HIGHLANDS LT 8 G:0155 Owner/Address: QUINN MICHAEL CONSTRUCTION LLC PO BOX 77264 ANCHORAGE AK 995777264 Site Mailing Address: This permit is for the construction of: Y Disposal Field Y Septic Tank Lot Size in Sq Ft: Total Bedrooms: N Holding Tank N Privy N Private Well N Water Storage 73782 All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. AWWiS Maintenance Agreement shall be submitted prior to inspection report approval. 2. PRIOR TO CONSTRUCTION: Test Holes substantiating the alternate drainfield design and an approved change order if required shall be completed and obtained prior to construction. Test hole results shall be submitted with the inspection report. 3. PRIOR TO CONSTRUCTION: Percolation tests shall be completed for both the primary and alternate drainfields such that all portions of both drainfields are within 30 feet of a percolation test, and an approved change order if required, prior to construction. Test results shall be submitted with the inspection report. 4. All percolation test results shall be reporting the water drop using a tolerance of 1/16" or better. Receiv Issued Jam, T�e /Ye Se.v� Girea is #v ba 6tme4Q on fA-1,91at Ae / /af dote Prior a"O Z� exarovo 1. Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907)343-7904 • Fax(907)343-7997 htti)://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program Ment �� SN J n Department **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV161026 COSA#: Permit#: OSP161041 PID#: 050-315-66 Legal Description: Roseberry Highlands, Lot 8 Engineer: North Rim Engineering Applicant: Quinn Your request for a waiver of the required 50 feet horizontal separation from the absorption field to a 25% or greater slope has been approved. The approved separation distance is 23.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted:: /X Waiver is not Granted: Date: / / `* Approved b Nameo evi.wer ............................................................................. RAUNUPALITY OF Community Development Department\� Development Services Division On -Site Water & Wastewater Program AmCHORAGE ON-SITE SEWER/WELL PERMIT APPLICA Parcel I.D. C� 4p— 315— 66 Property owner(s) 01 -)AAI t/ Mailing address _ 2 Day phone e 90� 3�3-7904 Site address /)// i r "R. Legal description (Sub'd., Block & Lot) /�Z 41-t F,Bf{i A(=e FA JA G Legal description (Township, Range & Section) Lot Size 3 �ZSq. Ft. APPLICATION IS FOR: 0 all that apply) Absorption Field TYPE OF DWELLING: Septic Tank Initial Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms APPLICATION IS AN: TYPE OF DWELLING: Initial Single Family (SF) R / Upgrade F-1(w/wo ADU) F1 Duplex (D) El Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: 1 Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Permit/Rush Fees: .!2&q Waiver Fees: Date of Payment: 39!/&_ Date of Payment: Receipt Number: bReceipt Number: d I Permit No. X35 PZ( q1 Waiver No. DQE,/ Z ro4a ic�' Permit App_9-1-12.doc �C;2TN I�- ENGINEERING Date: 3/18/16 To: J. Crewdson PE MOA On -Site Services MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel SteveEngPE@gmail.com Subject: Roseberry Highlands Lot 8 Your Comments 3/17/16 Number of Pages: 3 This is a new subdivision. Neighbor lots are undeveloped. A new Advantex & shallow trench is being utilized to conform with Category III plat requirements. Private water wells serve the area lots- an existing well remains from the subdivision aquifer test. A maintenance agreement to be provided with Record Drawings. 2. See above statement. 3. Alternate field test hole to be completed during construction. 4. Additional perk tests to be completed during construction. 5. Cleanouts & monitor tube identified. 6. A slope waiver is requested per the attached Slope Waiver, Sheet 4. At the 35 -foot point downslope, the slope is above the 25% slope line. 7. New perk tests to be conducted during construction. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Thanks -Steve 2Tf- I� M ENGINEERING 3/8%6 Roseberry Highlands, Lot 8 SPECIFICATIONS/&_DESIGN GUIDELINES Wastewater System Sizing: This is a new 4 -bedroom, single family home, in a new subdivision. Most of the neighboring lots are undeveloped. The 5-10% slope at the site will accommodate this design. The soil test from the subdivision was used for design. The subdivision plat requires an Orenco System, AdvanTex. This system requires a 1500 gallon processing tank and 1-AX20 filter pod. Separation to bedrock and groundwater is being maintained. The easements are located on the drawing and are not encroached upon. Soil tests revealed silty sandy soil. A Category III System drain field will allow an application rate of 6 GPD/FTI. Length =100 FTI/5'x 0.5 reduction factor = 10' trench, say 15'. Specification Requirements: All components and work must comply with the MOA Specifications (AMC) & State DEC, Orenco Systems Regulations • Installation by an Authorized AdvanTex Installer only; approval issued by Orenco Systems & Anchorage Tank & Welding, Inc. • 1500 gallon, two compartment AdvanTex processing tank, 1-AX20 filter w/50 gpm pump, VeriComm Monitoring System & Mode la standard package per AdvanTex Treatment System Manual. • Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' minimum to property lines. • 3' of cover or insulation is required for trench; an equivalent of 1" insulation for l' soil cover. Minimum 2" insulation. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required F to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, prior to the processing tank. • All cleanouts must extend to at least ground level • Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock. • Drain rock to be %I" to 2 ''/2' screened. Drain rock to be distributed uniformly. Perforated pipe to be installed level with perforations down. • Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • The finish grade must be mounded to promote drainage away from trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope • Maintenance agreement for the AdvanTex Treatment System is required for approval. • Insulation board shall be extruded direct burial polystyrene (Dow Styrofoam HI or equal) L DESIGN NOTES1 1. New Trench Depth At 7'. 2. 5' -Wide Shallow Trench. 3, 3' Cover Over Trench, 4' Over Tank, 4. Lots Served by Private Water Wells. 5. No Conflicts Within 200'. 6. TH3 From Subdivision Soils, Undeveloped NOR THRIM ENGINEERING PO Box 770724 Eagle River, Alaska 99577 907.694. 7028 500 Gallon AdvanTex Unit 1 AX -20 Filter _ift Station ���, P��.OF -v Sk4� R❑SEBERRY HIGHLANDS asmi��* LOT 8 ;PLAN ft= LAYOUT jh ° WASTEWATER DESIGN ,UPGRADE SEPTIC 3/18/16 V = 100' EET: 2 of 3 0 U W 75 a 3 L Uo M 0 U u C N - L 4 L O o U7 x41 Cl. �O a 0 U n �Z N� ZW nx �W Q �?0 OZ 0Q: ZW am 0 W W 75 N 3 L Uo M C f L7 d W W S � �O a a, L El > Q u uU z QJ U U Q 4 Q J W v Qj v > > d d l� u U C5 O U L O H O £ L U O M L I U 06 aZ 0 O a O O T v u Ud + c a > U LN Q d O a 3 W N £ U UI 1� UIwM v 5 5 �D L 0 W O F4QJ �_ d N W O dL N UI mQj S £ u Qj 0 � r� 0 6-,7 v v� e q- o o nf� U g a°6 3 Q, W N U d U UI H => u +1 S U O L H ~ W X (%1 pij 01 U £ Y O N [/1 N N o+,C50aiw H H z z C7 v Obi z C,) rte¢ N d ai v3v¢ W p ri N M V U7 �o n �Z N� ZW nx �W Q �?0 OZ 0Q: ZW am 0 W W N M C �O Q u z Q J l� H I yyN n LL/ Q i, p 1� UIwM �D W MM W � N W 0 � r� E e nf� J g 3 w H H H z z LLJ w z = x U W z � w z U � Q � �- > Q U Q m n �Z N� ZW nx �W Q �?0 OZ 0Q: ZW am 0 W Ln m W J L� 0 w r 0 J I � Ln QJ C5 L- W, SOILS LOG - PERCOLATION TEST ��2TI iZM _ [NG-INEERI iG Date Performed: 8/15/07 Performed For:L-eP Cov �,c)al 7Pscriptior: Roseberry Highlands Lot $ DErTH (Previously Roseberry Ridge Highlands Lot 5) (FEET) ❑rganic SP Sand W/ Gravel Low Silt Cobbles Refusal Large Cobbles See Location Map Slope < 10% Groundwater? No Depth none Water Depth Ater Monitorino.12' Date: 10/17/07 # Date_ Gross Tine Net Time Depth Vet Dr, ,- i 1 8/15 0 -- 5' -- 2 8/15 1D 10 mir, 10" 3 8/15 10-- 4 8/15 20 10 mir, 10' S" 5 8/15 20 -- 5" -- 6 8/15 30 10 mir 10" 5' Percolation Rate 2 min./inch Rerc Hole Diameter Test Run Between 4' and 5' Five- 5Ll Sar 2rtorned By NorthRim- Lng. I CERTIFY THAI THIS TEST WA Performed in Accordance with All State/Municipal Guidelines in U-,-,C--T ]v ;HIS DATE, DATE: 8/15/07 ?��++OF • ij 1 NORTH A4 :�P�E....�c ENGINEEF?INc `(;4981 TESTHOL.E LOG T, H. 3 �' GEOTECHNICAL PC? Rox 770724 F1 =.°A., Pi,Nr. ^.+� ka 99577 : RoseberryHighlands Lot � �j8/15/07 3Eol _, O(,"L 17 08 07:69a Sullivan Water Wells 907 685 2759 SULLIVAN WATER WELLS BOX 670272, CHUGtAK, ALASKA 9~$67 *TELEPHONE 66;~2TS9 p,l OWNER OF LAND: ____ _ ADDI:~ESS: Me~ of Dri~:~ ro~ Depth of w~l: ~lng Type~[ r,,,W~ll ~kress_ , '~ _imPs ~ Ty~ ~i~ 511ckup A~e G~d: ~ ~ f~t R~ Ral~ ~, ~ gpm Meth~ ~ Well lnlake O~ni~ 8ORE HOLE DATA DEPTH Comments: Driller's Name ,~TTENTION: it is, the resp~nsibillty of ti9 pmp~/y o~er to ~bmit a copy of ~e ~1 Icg to the pmp~ aut~orit~ Mu~paliW ~pad~n~ of Enviro~enlal Cons~ion. MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Sep 11, 2008 Expiration Date: Sep 11, 2009 Permit Number: SW080'194 Parcel ID: 050-315-22 Legal Description: ROSEBERRY RIDGE ESTATES #1 TRACT A Design Engineer: 0000 ZZ - NONE NEEDED Site Address: NHN MOUNT MAGNIFICENT CIRCLE Owner Name: ROSEBERRY RIDGE ESTATES, LLC Lot Size: 649452 SQ. FT. Owner Address: '10230 RONALD PLACE Total Bedrooms: 0 Permit Bedrooms: 0 EAGLE RIVER, AK 99577- This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. Tl'jg,~l~.wing,special provisions. Municipality of Anchorage Development Services Department Building Safely DnnS~On On-Site Water and Wasteweler Program 4700 Bragaw Slmet P.O. Box 196650 Anchorage. Alaska 99519-6650 www. muni.org/onS~te (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 05031522-000 Property owner{s) Roseberry Ridge Estates, LLC Day phone (907) 360-7157 Ma lin-' address 10230 Ronald Place, Eagle River, AK Zi- Code 99577-8769 Site address Mount Magnificent Circle, Eagle River Zip Code 99577 Legal description (Sub'd., Block & Lot) _R~;_e_..b.~y~._R._~_d~.~ E~_tates #1, Tra._c_t_..A__ Legal description (Township, Range & Section) T14N R1W Lot Size 649~_5~ .... Sq. Ft. Number of Bedrooms ..~_~._N/.~A. THIS APPUCATION IS FOR ([] all that apply): Absorptio~ Field [] Septic Tank ~ Holding Tank ~ Pdvy ~ Private Well [] Water Storage ~ THIS APPMCA'rlON IS AN: Initial Upgrade Renewal [] This Application is forWell f 3wells required for the Aquifer Test for Preliminary Plat S-11628-3 Roseberry Ridge Highlands. I certify that the above information is correct. I further certify that this application is being made for a Singla Family Dwelling and is in accordance with applicable Municipal Codes. (Signature o~ property owner or ~ &gent} Permit/Rush Fees: Date o~ Payment: Receipl Number: Waiver Fees: Date o! Payment: R~;eipt Number: ~Z