Municipality of Anchorage
Community Development Department
On -Site Water and Wastewater Program
4700 Elmore St. • P.U. Box 196650 Anchorage, AK 99519-8650 • hltp:!lwww.muni.orgfonsite • (907) 343-7904
Well Decommissioning tog
legaldivis i l�li� ?r� r.1%
Subdivision c'l Bioak Lot
T� R ) Seedion—L(-- Lot
Onnalira rWator & Wastewater Program certified contractor performing the well deconnmWelonInM
Na • $' F.r fT.fi r'td.E V
Signature:Y • /7 C ��`i'�74�Y
Well decommissionUig date =.1 �o Method of derormnissiwting: AMC 15.55.060L1 e. Q b. Q C.
Location: Woes space belowto protide a drawing of the property showing the fdlwp term;
• Ndtth arrow
• DeonmtnlWomd wail,
• Other water wells on the property,
Two separate swing4e distances rrx each well ehopm on the drawing,
Note: The swing-tia distances shall ba measured hart either pennanentabudures or the property corners. [ V
i
Oecml7�k �-"Itlo �eJ utaaft
xxarer And xuaewwaxeru-armou„liem tormawVeg necommlefomng form.doo
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP161055
Tax Code Number: 01123104000
Work Type: Septic Upgrade
Permit Effective Dates: March 29, 2016 to March 29, 2017
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: T12N R4W SEC 16
Site Legal Address: T12N R4W SEC 16 LT 1 G:2423
Owner/Address: KOBUK INVESTMENTS LLC
3317 MT VIEW DRIVE ANCHORAGE AK 995010000
Site Mailing Address: 5500 W DIMOND BLVD, Anchorage Lot Size in Sq Ft: 1798953
Total Bedrooms: 6
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued
I&AIN .�
���� RUSH�y9 8'y 70
..J
MUNICIPALITY OF ANCHORAG ti RUSFff
MRR 2 g Z01
QD
Community Development -Department Phone: 91 43-7904
43-7904
Development Services Division Fax: 90
On -Site Water &Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 011-231-04
Property owner(s) Kobuk Investments- LLC Day phone
Mailing address 3317 Mt. View Drive, Anchorage, AK 99501
Site address 5500 W. Dimond Blvd
Legal description (Sub'd., Block &Lot)
Legal description (Township, Range &Section) T12N, R4W, Sec 16, Lot 1
Lot Size 1,798,953 Sq. Ft. Number of Bedrooms 6
APPLICATION IS FOR: - APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply) _
Absorption Field _ Q Initial ❑ Single Family (SF) Q
(w/wo ADU)
Septic Tank � Upgrade 0 Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES AVARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment: 51dY//So
Receipt Number: 061TJr*
Permit No. 0s11?1110 105T
Permit App_- :-:'-._c,
'//0 ' Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@t)anengak.com
March 23, 2016
Subject: T12N, R4W, Sec 16, Lot 1
Septic System Upgrade Permit Request
Design Narrative
This is a design narrative for a permit to upgrade a septic system to be issued for this property. The
proposed systems will serve an existing six (6) bedroom house. Currently the lot is developed. This lot and
the surrounding developed lots are served by private wells that are over 200' from the proposed
development on this lot. There are no wells within 100' of the proposed septic system.
Soils. One test hole was performed on this lot by PES in -March of 2016, and groundwater was
monitored for at least seven days. Ground water was not observed to a depth of 19.0' below the
surface in the test hole monitor tube in March of 2016. Bedrock was not encountered in the test hole.
Based on the results of the percolation tests and overall soils appearance; an application rate of 1.2
gallons/day/square feet was used for a conventional wastewater system in the area of the test hole.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100' of the proposed septic system. The system
will maintain 100' of separation to all surface water.
4. Topography: The existing topography generally slopes from the north to the south in the area
surrounding the septic system at approximately 5%. There are no steep slopes within 50' of the proposed
drain field. The proposed drain field will maintain 50' separation all steep slopes.
S. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that
the review is complete and that there are no further comments is received from MoA On -Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
DRAIN FIELD (P)
(2EA) 35LF x 2.5'W x 6.0'ED x 13.0' TD
INSTALL MONITOR TUBE AND CLEAN OUT
AT EACH END
NO SURROUNDING WELLS OR SEPTICS WITHIN 200'
50' SECTION LINE EASEMENT
DRIVEWAY (TO WEST DIMOND)
55.0
ss
T12.0
DECOMMISSION EXISTING
DRAIN FIELD PER CODE
TH-1
DECOMMISSION SEPTIC TANK (E) PER CODE
INSTALL 2000g SEPTIC TANK (P)JC" HOUSE
INSTALL FOUNDATION CLEAN OUT, DOUBLE (E)
CLEAN OUT AND FLOW SPLITTER
133.3
B( LFF
\
DESIGN PARAMETERS
UPGRADE SEPTIC SYSTEM
NO. BEDROOM: 6 (900 gpd)
TANK SIZE: 2000g (P)
PERC RATE =. 3.9 MPI
SOIL RATING: 1.2 GPD/SF
AREA ROD: 750 SF
SYS. TYPE: DEEP TRENCH 6.0'ED
MIN LENGTH: 62.5 LF
USE:
(2EA) 35 LF X 2.5' WIDE, 6.0' E.D., 13.0' TO
TOTAL AREA: 840 SF
LEGEND
W WATER LINE/
WELL RADIUS
SS NEW SEPTIC
ABBREVIATIONS
Cu
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN C
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R. 1.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BEG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
NOTES: PANNONE ENG SVC, LLC+— of a� lk Date
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r '(� •" gsll, 3/zs/zots
PHONE (907) 272-8218 FAX (907) 272-8211 %aj�P9�r Scale
t.._50,
.... .. .. ... P.I.D. NO
T12N, R4W, Sec 16, LOT 1 31-04
/••Steven •R. Pannone•
KOBUK INVESTMENTS LLC / / PERMIT No.
/ PND BLVDH.', CE 81495500 W .fir OSP161055
PLAN ANCHORAGE, OAK 99567 +��1>,�OoEESSio�P Sheet
i,�ROFESS �' 1 OF 3
READING
SOILS LOG - PERCOLATION TEST
CLOCK
TIME
TEST HOLE 1
WATER
LEVEL
READING
NET DROP
OR ORGANICS
SLOPE SITE PLAN
1.
--
6.45
2
2
2:30
10 MIN
9.53
3.08
a
N
3
--
6.45
4
4
6
10 MIN
9.06
- 8 - -
X TH-1
2:40
TH
6.45
7
s
8
10 MIN
68R
SM/ SILTY SAND TO
HOUSE
9 SW SAND
(E)
10
11
12
13
WAS GROUND WATER
SLOPE
14
ENCOUNTERED? N
15
IF YES, AT WHAT
TH
DEPTH? -DRY
X
16
17
DEPTH TO WATER AFTER
MONITORING? -DRY'-
18
DATE: 3/23/2016
1s
BOH
20
DATE PERFORMED: 311612016
PEROLATION RATE 3.8 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 5 FT AND
6 FT
COMMENTS: Test hole excavated by BEEK'S CONTRACTING. Pree hole was
presoaked.
Test run for at least one hour. Last 3 readings reported
PERFORMED BY: Steven R.
Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE
OF THIS TEST.
NOTES:
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
: 'oF a �V
��•..•..Cgsl�'
j rij�p �yf�'
Tt:
Date -
3 25 2016
FOR CONSTRUCTION
Scale
NTS
/
%.... ... ... ...•..
P.I.D. NO
T12N, R4W, Sec 16, LOT 1
...•.......• ••.. ....
31-04
KOBUK INVESTMENTS LLC
Steven R. annoRe /
PF.'. CE 8149
PERMIT NO.
5500 W DIMOND BLVD
ANCHORAGE, AK 99567
. c`t�
I+c .
�l�lFpN�OESSOPP�+�
OSP161055
SOILS LOG
Sheet
S90
2 OF 3
READING
DATE
CLOCK
TIME
NET TIME
WATER
LEVEL
READING
NET DROP
1
3/16/16
2:20
--
6.45
--
2
2:30
10 MIN
9.53
3.08
a
2:30
--
6.45
--
4
2:40
10 MIN
9.06
2.61
s
2:40
--
6.45
--
s
2:50
10 MIN
9.03
2.58
SPECIAL PROVISIONS TO SPECIFICATIMS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55.
2. SCOPE OF WORK: INSTALL NEW SEPTIC TANK AND SOIL ABSORPTION SYSTEM.
3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 19 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE
SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 19. FEET
BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
4. THE CONTRACTOR (BOTH WELL AND SEPTIC: SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC
LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED
SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. _
5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED.
1 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.
7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING
AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER.
I 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE
CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN.
9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE
ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND
TANK ELEVATIONS.
10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF
EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING.
11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE
PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE
ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN
DEFECTS BY THE CONTRACTOR.
12. THE CONTRACTOR SHALL SIGN THE FOLLOWING:
I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE
ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS
CONSTRUCTED.
CONTRACTOR:
BY: TITLE:
NOTES: PANONE ENG SVC, LLC ' N Date
FOR CONSTRUCTION ,�- L
P.O. BOX 100217 ANCHORAGE, AK 99510 r '�. • " "' q5' l( 3/25/2016
PHONE (907) 272-8218 FAX (907) 272-8211irg�P �yTo Scale
*Ir NTS
.... .... ... .. P.I.D. NO
T12N, R4W, Sec 16, LOT 1 011-231-04
KOBUK INVESTMENTS LLC r Steven 'R. Pannone'% PERMIT NO.
5500 W DIMOND BLVD % CE 8149�r OSP161055
,
DESIGN DETAILS ANCHORAGE, AK 99567 �1�•..•...PEG sheet
lid\ oFEss+ 3 OF 3