HORIZON ESTATES LT 1
Horizon Estates Lot 1 #051-324-21 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151269 PID Number: 051-324-21 Dwelling: H Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: X New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench N Bed ❑ Mound Address 1689 Knik Goose Bay Rd. #400 Wasilla, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 357-9394 3 .5 GPD/SF 2-3 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.5-2.5 Ft. Gravel depth beneath pipe .5 Ft. Subdivision Block Lot Horizon Estates 1 Fill added above original grade .5-1.5 Ft. Gravel length 65 Ft. Township Range Section Gravel width 12-24 Ft. Beds: Number of Lines 3 Distance between lines 6 Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1,000 Fe Ft. Well >100' >100' >100' >75' >25' TANK ❑ Septic N S.T. E.P. []Holding ❑Other Manufacturer Anchorage Tank Capacity 1,250 Gal. Surface Water >100' >100' >100' NA Material Number of compartments Lot Line >5' 3.5'* >5' NA Steel Three NA Foundation >5' >10' >5' NA LIFT STATION Manufacturer capacity Curtain Drain None Noted Anchorage Tank/Orenco 250 Gal. Remarks 2" Insulation Over Entire Absorption Pump on level at 42 Pump off level at 38 High water alarm at 44 Bed. *See lot line waiver. In. In. in. Pump make and model OSH P2005-11 Electrical Inspeclions performed by Commercial Electric Inc. Installer Tankto PIPE MATERIAL House to tank D2665 d ainfield D3034 Northern Excavation Dainneld F810 CO/Mr Inspector MEA BENCHMARK (Assumed elevation) 100.0 ft Inspection1e' 4/19/16 4/20/16 Location and description dates: 2.a 3b 4/24/16 4'" Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 4�0 �4k gs�oo` Conditional Approval: Date �Q:�•• e,� : 49TH 4 AMICHAEL E. ANDERSON JL• CE-4381 ; •__� �I rfj•., 5-3 r6.•���� e,+�o�e Approved47 Date S C ®e®oo® Fo, T• E. Inspection Rep rt_9-1-12.doc 1 Permit Number: OSP151269 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 9_9519-6655 - 343-7904 PID No. 051-324-21 Lot 3 1 S 89'56'55"E 147.33' Lot 4 rj TRACT B 2 ;+ : 49th mttl... . �.. ......................................... . :•MICHAEL E. ANDERSON ^ 4 No. CE -4381 ;'r.ti'�, / /75.0' ! pRore�r Boa, n. I e RgOj�S I 1 Existing Well LOT 1 1 HORIZON ESTATES 1 \ 40,129 sq.ft. TH16 p3Bedroon ALTERNATE SITE Advantex Treatment System with 10' Long x 10' Wide x .5' Effective Depth Absorption Bed. 5 GPD/SF Absorption Rate. Alternatd\e Hi 5.' 5Q. 43 MULDROW STREET ,000 SF Bed 10.74' PLAN AS BUILT SCALE V = 40' T & E EASEMENT DIM LEGEND MT — Monitor Tube FCO — Foundation Clean Out TH — Test Hole CO — Clean Out FSV — Flaw Splitter Valve / 1 1 / 1 / / r 1 I I I I I I I / 1 w / Well � o / / 1 N 1\ m Lot 2 / W N \ / S1 \ S2 \ MH — MI1 10.1' 12.3' T{14.1' *S2 34.1' ,000 SF Bed 10.74' PLAN AS BUILT SCALE V = 40' T & E EASEMENT DIM LEGEND MT — Monitor Tube FCO — Foundation Clean Out TH — Test Hole CO — Clean Out FSV — Flaw Splitter Valve Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP151269 98.4 N 105.3 1,250 Gallon STEP Tank 1/01.5 = Finished Grade i ~ 2" Insulation & Geotextile Fabric Drainfield Rock 97.91 o Groundwater@93.9 u 4-27-16 86.9---' 30 - 16" Diameter Holes @ 5' Spacing 100.4 Page 3 of 3 aI1715XII-YIESYZ6'l�I 0 97.91 Groundwater @ 93A 91.4--' 10-15-15 PROFILE AS -BUILT No Scale 98.4 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT I, HORIZON SUBDIVISION PERFORMED FOR: TROY DAVIS HoMEs DATE: 10/21/13 PROJECT No.: PARCEL ID#: TECHNICIAN: W. ROBERTS DEPTH TEST HOLE A (feet) 1 OB/OG SILTY GRAVEL 2 a d WITH SAND GM 3 BOH @ 3' - BED LEVEL 4 5 6 7 8 9 1 O WAS GROUND WATER ENCOU F YES @ WH. DEPTH OF WATER AFTER MOL I I DATE OF MO: 12- 13- 14- 15- 16- 17- 18- 19- SLOPE 213141516171819 SLOPE No SITE PLAN SEE SITE PLAN 9 IA ,T DEPTHS ITORING: 0 JITORING: P EGROSS 2% DATE READING TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/11 1 2:15 1.63" 2 2:45 30 4.88" 3.25" 3 2:46 1.50" 4 3:16 30 4.75" 3.25" 5 3:17 1.75" 6 3:47 30 5.00" 3.25" PERCOLATION RATE: 9.2 (MINANCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 3.0 FT. and 4.0 FT, COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 4/28/16 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1- 2 - 3- 4 - 5- 6- 7- 8- 9- 10- 11 1 17 18 19 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT I, HORIZON SUBDIVISION PERFORMED FOR: TROY DAVIS HOMES DATE: 4/19/16 PROJECT No.: PARCEL ID#: TECHNICIAN: W • ROBERTS TEST HOLE B OB/OG � d a a 7 d A a 1 d SILTY GRAVEL WITH SAND GM BOH @ 14' SLOPE SI I E PLAN SEE SITE PLAN WAS GROUND WATER ENCOUNTERED? YES IF YES( a WHAT DEPTH? 7.5' S DEPTH OF WATER AFTER MONITORING: 7.5' O 2% DATE OF MONITORING: 4/26/16 GROSS TIME NET TIME DEPTH To NET DROP DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: PERCOLATION RATE(MIN/1NCH) PERC. HOLE DIA. INCHES) TEST RUN BETWEEN: FT. and FT. COMMENTS: TEST HOLE FOR WATER MONITORING ONLY. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 4/28/16 To whom it may concern, Horizon lot 1 lift station is to NEC electrical code and acceptable in the state of Alaska. Sincerely, William Regallo Electric Administrator #1904 Commercial Electric Inc. Development Services beportment Ruilding Safety Division Ott=Sitt WGtCr A WOSteweter• Pi f'piP11 4'7M Eirtcre Road P 0 Box 186659 Anchorage, AK 94347 ;9M 3<3-7904 Well Log Permit Ramber:,O 2tM21 hate of Issue. q�j�t5 P plIde3!tiflcsdonptMtenaS1-324-2i DMeStarttil:1003M15 Date _ tad:lntt4rm13 tswellk"ictlatapproaedppemutlocation7EI Yes d No I Agal Des ription. Lot ! lwarlwn ea"" sirs low Muirtrow 6t €atpe Prmpoly Owner Nasse & Addrre L Ttav 0ataa E onwo 168 E Paft fMy Sts 204 Vftaiv. Ail 9981 Borehole Data: beptb (R) SGil Type, Thicko & WhiOu.Sista From TO Water Gravad WALT Resmalra nrswk �U� 6 Vg"L Nwaws_ YEN mg -l- Tt"i +C'nliferm gaactia culoaic& I0©mL r,.7 Wall TMcltaress..25 iwhct Vianwtcro inches :61foes Llnerr Type: Nam Diwiwwr: inches NO, _ r=ent tCaaing tadutp above gromml: 3 ftct Stacie water kers! (hum ground leveli`i8 fest Pumping kwel:D fed of cr hiknns$_Spin Recovery (Rate: 6 go _Metkod afTesdp.g_ laskklo" A I)epih_27 Slartot it" 5"TL4fed Pump- labia Depth 3E— fed Pump size i bp Brawl Nam qoLft Wes, wiofected up" i`otrNpittkw-? 21 yes 0 Nis Method of llismfitirWn. Chkdm Tablets Cuu®enist YWtar.9arrtpla tMw - raftft rOmred to TM liF'sll flrilleT= a4oa Wakbr V!i4is lt10 ratmp Attention, Tate w4l driller droll p9rvide a wtil loll to DSD wtthin M clays ofcrinoctioa. Mayor Development Services Department Building Safety Division On -Site Water & Wastewater Program *AE 4700 Elmore Road P.O. Box 1.96650 Anchorage, AK 99507 www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP151268 Parcel Identification Number: 051-324-21 Date of Issue: 09/04/2015 Legal Description Property Owner Name & Address: Lot 1 Horizon Troy Davis Homes I 11 18036 Muldrow 165 E. Parks Hwy Ste 200 Eagle River Wasilla, AK. 99654 Pump Installation Date: 10/15/2015 Pump Intake Depth Below Top of Well Casing: 50 Pump Manufacturer's Name: Goulds Pump Model: Bruiser Pump Size 1/2 hp Pitless Adapter Burial Depth: 122" feet feet Pitless Adapter Manufacturer's Name: Not installed by this contractor Pitless Adapter Installer: unknown Well Disinfected Upon Completion? Q Yes ❑ No Method of Disinfection: chlorine tablets Comments: Water Sample taken - results returned to Troy Davis Homes Pump Installer Name: Ace Water Wells and Pump Works P O Box 520090 Big Lake, AK. 99652 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. On -Site Water & Wastewater System Permit Permit Number: OSP151269 Tax Code Number: 05132421000 Work Type: WellSeptic Initial Permit Effective Dates: September 04, 2015 to September 03, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: HORIZON ESTATES Site Legal Address: HORIZON ESTATES LT 1 G:0553 Owner/Address: TROY DAVIS HOMES INC 165 E PARKS HIGHWAY STE 200 WASILLA AK 996540000 Site Mailing Address: 18093 MULDROW ST, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 40128 Total Bedrooms: 3 Y Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.B.3 CO#2 4/14/16 Constructed bed built in the wrong location, change order submitted to rebuild with a redesign. Received Issued By 11111 Ill MUNICIPALITY OF ANCHORAGE ' Development Services Department On -Site Water & Wastewater Program + I 4700 Elmore Road, PO Box 196650 1)charunent Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151269 Tax Code Number: 05132421000 Work Type: WellSeptic Initial Permit Effective Dates: September 04, 2015 to September 03, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: HORIZON ESTATES Site Legal Address: HORIZON ESTATES LT 1 G:0553 Owner/Address: TROY DAVIS HOMES INC 165 E PARKS HIGHWAY STE 200 WASILLA AK 996540000 Site Mailing Address: 18093 MULDROW ST, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 40128 Total Bedrooms: 3 Y Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.B.3 CO#2 4/14/16 Constructed bed built in the wrong location, change order submitted to rebuild with a redesign. Received Issued By C-0 Z Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907)343-7904 • Fax(907)343-7997 http:llwww.mu ni.ong1O ns ite Development Services Division On -Site Water and Wastewater Program went S i G. r N Depni tment **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV161118 COSA#: PID#: 051-324-21 Legal Description: Horizon Estates Lot 1 Engineer: Anderson Engineering Applicant: Troy Davis Homes Permit#: OSP151269 Your request for a waiver allowing 2:1 side slopes on the proped mound is approved. Ll.eflag . This waiver approval applies to the proposed absorption field only. Any future upg e to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ..............................................................................1 Waiver is Granted: x Waiver is not Granted: Date: I �� r' Approved by: ame of Reviewer ............................................................................... C� / L rl /1y�6 ��j11SorPi 'on �(ela r alpow6 4-o 6L '-l' �-ro �unUaiibr � �jec{ ap✓//D�Nf� -fry �jegreater i%lan LTJ' � wr��� MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I. D. 051-324-21 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654 Site address 18093 Muldrow Street Eagle River, AK 99577 Legal description (Sub'd., Block & Lot) Horizon Estates, Lot 1 Legal description (Township, Range & Section) Lot Size 40,128 Sq. Ft. Number of Bedrooms Three APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X (w/wo ADU) Septic Tank NUpgrade ❑ Duplex (D) ❑ Holding Tank F-1Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. C (Signature of property owner or authorized Permit/Rush Fees: '%q -t 245 'J Date of Payment: 0-11m G� +�- Receipt Number: d2J-59'X (1 Permit No. 0SP1 5 %7-601 Permit App_ .::L�c Waiver Fees: 0o Date of Payment: gIe2 9// Receipt Number: ��/1S 7� 67— Waiver No. OW (S( t IS C CZ ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 4, 2016 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Horizon Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Horizon Estates Subdivision intends to construct a new three- bedroom home on the lot. We are requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the proposed and existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and the well or septic systems and wells on adjacent lots. Drainage arrows and ground contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. No surface water is currently seen in the easements and no evidence of past drainage was noted. The test holes placed on the lot indicated silty gravel with sand (GM). The percolation rate of the soil was determined to be 9 to 11 minutes per inch. Groundwater was found during the placement of the test holes and stabilized during the monitoring period at 7' below the surface on October 14, 2015. An application rate of .5 gallons per day per square foot was used in the design of the absorption bed. We are proposing to place a new 1,250 -gallon STEP tank and a 900 square foot absorption bed in the configuration shown on the Site Plan to treat and dispose of the effluent generated in the house. The total absorption area for the bed will be 900 square feet. The elevation of the distribution line in the absorption bed will be 2.5' below the existing ground with a total depth of 3.0' from existing ground at the north end which will be the basis of elevation control. The existing ground surface in the area of the bed slopes 1' from north to south. Total depth of the bed will be 3' below existing ground at the north end as stated above and 2' at the south end due to the slope of the existing ground. Coarse sand will be utilized to level the bottom of the absorption bed as required. A minimum of 2" of insulation and 2' of fill will be placed over the absorption bed and 4' over the septic tank. No fill may be placed on the adjacent Lot 2. C 0'&j Lot 1, Horizon Estates April 4, 2016 Page Two The existing segment of the absorption bed which falls within the protective well radius of the well on Lot 7A, Block 1, Fire Lake Subdivision and within the cul-de-sac easement will be removed. The pipe currently in place and all drainfield rock will be removed and replaced with in situ silty gravel material. The material will be compacted to the same density as the surrounding material. The ground surface on the lot in the area of the septic system slopes to the south and southeast at a shallow grade. The new absorption bed will be constructed slightly off parallel with the contours of the slope due to the limited area available for the bed. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water service lines in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments wl�".• �! 49th n*lei MICHAEL E. ANDERSON . No. CE -4381 LD -4z ♦♦♦♦� irrr1® ♦ ;: Am i o P c c :°•�ff '' N • 4 m a ° O% f✓, �� a zi ��p/J t ..aauax E.cxsa.,. /a �L®-L_ AV Ar ♦�� yin w� ♦ �♦♦ TRACT B 2 RECREATION CRNTER 'SUgC,) ZL'66Z cn \ / o � Xr V1 in r X ti✓�, N _ t9 of C7 3 � Cli LTi N D-P, cz F9 D D r ri C D 11.002 ]"00,20.00S TRACT C OF Go"ZRNME 6 NT LST AND c (-00'9-6) 6, TRACTS A. Lot 3 S 89'5655"E 1-47.33 Lot 4 0 49t" . MULDROW STREET ............................................ 3, : MICHAEL E. ANDERSNN LEGEND MT — Monitor Tube r �.. No. GE -4381 : = •, •� Vti� SITE P LAN TG° TH —Test - toundehon Cleon o�t Hole �Jj, �F�'•. ,y -ll ...• ��� �� � CO — F5V Cleo, out —Flow Sputter Valve ��� 1R�EESS ..____ SCALE 1° = 40' - © Existing Well TOT 1 HORIZON ESTATES/ - Z 0 40;129 sq.ft. i o "Val 0 o CID no :9 ? Lot 2 ALTERNATE SITE F Adventex Treatvlenl System with 10 ' W Leag x 10' Wide x 5 Effective Deptn_ .W N sorption, Bed. 5 GPO/ST W N Abs teri Rate. W z Q _ 7 ti••=/ U > T t& T _ 1,250 Callon / 3;Bedroofrl STEP Tank House 12 TI Q zz IM _,_ - Revise Alignment L ' - .. - Necessary Su Necessary to Provide Sufficient Area for Absorption Bed Fill Slope Shall Not Exceedeed 2:1. ' ' Al temat�Sit@/ H15'_ P,e 900 Sq/uore Sq/ore toot x .5' Effective Depth D Absorption bed z<MT� ------- - ------------------ ---------- TRACT B 2 ` S NOTE: �`. 4�S2 Op• 1 T k E EASEMENT DTM 43. $9*58�28°W No Areas of Excessive Slope or 1 �0.74� .\, ,� (�F r )�- Surface Wet, ere Within 100' of Any Part of the New Septic System. o 49t" . MULDROW STREET ............................................ 3, : MICHAEL E. ANDERSNN LEGEND MT — Monitor Tube r �.. No. GE -4381 : = •, •� Vti� SITE P LAN TG° TH —Test - toundehon Cleon o�t Hole �Jj, �F�'•. ,y -ll ...• ��� �� � CO — F5V Cleo, out —Flow Sputter Valve ��� 1R�EESS ..____ SCALE 1° = 40' C,o � LOT 1, HORIZON ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS 3 Bedroom Home Shallow Bed System Perc. Rate: 6-15 Min./Inch 1,250 STEP Tank Application Rate: .5 GPD/SF 1' Total Depth Drainfield Rock (.5' Effective Depth) 3 Bedrooms X150 SF/Bedroom/.5 GPD/SF = 900 SF Absorption Area See Site Plan for Bed Dimensions = 900 Square Feet THEREFORE: Construct an Absorption Bed to the Dimensions Shown on the Site Plan. Effective Depth of the Bed to be .5'. Total Depth to be 3' at the North End and 2' at the South End. Distribution Line to be Placed at 2.5' Below the Surface at the North End and 1.5' Below the Surface at the South End. Maintain 100' Separation from all Components of the Septic System and all Private Wells on This and Adjacent Lots. Existing Ground 2.2' .5' .5' 3 O O Z (n Finished Grade 3 �1 1.2' 7Geo�textile ackfill Existing Ground abric 1&2Insulation 5' 1" PVC -{1— 5' �rairtirefdi2o �5%I6' 0140(-'s Underlying GM3v Ho(es 'o{a( a'i 55paunq 58' J TYPICAL BED SECTION (NO SCALE) NOTE: Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH ((cel) 1- 2 3 4 5 6 7 8- 9 10- 11 12- 13- 14- 15- 16- 17- 18- 19- 20 - SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 1, HORIZON SUBDIVISION PERFORMED FOR: TROY DAVIS HOMES DATE: 10/11/13 PROJECT No.: PARCEL ID#: T'ECHNICIAN: A. HARALA TEST BOLE 15 ............. n OB/OG 52 SILTY GRAVEL WITH SAND GM a BOH @ 9' SLOPE MICHAEL E. ANDERSON Y rofceslo nal SITE PLAN SEL Sire PIAN s --J WASGROUNDWAfERENCOUNIGRED?- YES IF YES (fid WHAT DEPTH?_' S DEPTH OF WATER AF EFR MONITORING:0 2°='-_ _. DAL E Of NION17 ORING. -1 15/15 p �----' DATE READING GROSS TIME (MINUIES) NET TIME (MINUTES) DEPTH TO NgTER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/11 1 13:13 1.75" 2 13:43 30 4.75" 3.00" 3 13:44 1.50" 4 14:14 30 4.38" 2.88" 5 _ 14:15 1.50" 6 14:45 30 4.38" 2.88" PERCOLATION RATE: 10.4(MIN/INCH) PERC. HOLE DIA.. 6�� (INCHES) TEST RUN BETWEEN: 3.5 FT. and 4.5 FT. COMMEN"FS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1. MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECTON THIS DATE: 10/20/13 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT I, HORIZON SUBDIVISION PERFORMED FOR: TROY DAVIS HOMES DATE: 10/11/16 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA DEPTH TEST HOLE l 6 (feet) SLOPE N .�;c l'�5� i• 49th_ - .* MICHAEL E. ANDERSON SITE PLAN SEE SITE PLAN a 1 READING OB/OG 1 DD jPTER 0 (INCHES) IFYES@WHATDEP7'H? S 2 a DEPTH OF WATER AFTER MONITORING: 4' SL 2% 3 a SILTY GRAVEL 3.2511 WITH SAND 4 a GM 5 3.2511 6 n 7 a 8 14:26 30 9 3.2511 BOH @ 9' SLOPE N .�;c l'�5� i• 49th_ - .* MICHAEL E. ANDERSON SITE PLAN SEE SITE PLAN a 1 READING WAS GROUND WATER ENCOUNTERED? YES W NET TIME (MINUTES) DD jPTER 0 (INCHES) IFYES@WHATDEP7'H? S TEST HOLE PRESOAKED PRIOR TO TESTING: DEPTH OF WATER AFTER MONITORING: 4' SL 2% 11 13:25 DATEOFMONITORMG 10/18/13 I 1 1 1 1 1 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DD jPTER 0 (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/11 1 13:25 3.2511 2 13:55 30 6.5011 3.2511 3 13:56 3.0011 4 14:26 30 6.2511 3.2511 5 14:27 3.13" 6 14:57 30 6.13" 3.2511 PERCOLATION RATE: 9.2 (MIN/INCH) PERC. HOLE DIA. 6H (INCHES) TEST RUN BETWEEN: 2.5 FT. and 3.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/20/15 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX August 6, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Horizon Estates Subdivision Trench Side Slopes Dear Onsite Services Engineer Absorption system sites on Lot 1, Horizon Estates Subdivision are limited by the presence of groundwater with few areas acceptable for the placement of an absorption trench. The most suitable area to place the new absorption is approximately 10' from the western lot line. The fill above the trench will be approximately 4' above ground. The 3:1 side slope will encroach on the neighboring property. We therefore request a waiver allowing the slope to be 2:1. The slope will be covered with topsoil and seeded with grass. Maintenance will be provided until a flourishing stand of grass is achieved. The 2:1 slope is standard for fill slope requirements in the Municipality. No erosion of the slope is anticipated once revegetation is complete. Sincerely, Michael E. Anderson, P.E. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX October 15, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 1, Horizon Estates Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: Very little surface area is available for a septic system on Lot 1, Horizon Estates Subdivision. An area suitable for effluent disposal has been found within 2' of the east lot line common to Lot 2, Horizon Estates. He new absorption bed will not impact either the well or septic system on Lot 2 as it is more than 100' from all wells in the area and more than 75' from the septic system or alternate site on Lot 2. We hereby request a waiver be issued allowing the new absorption bed to be 2' from the east property line. Sincerely, Michael E. Anderson, P.E. �; 49th •.•.� MICHAEL E ANDERSON . No. CE -4.351 . ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 9, 2016 CC) 4z - Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Horizon Estates Subdivision Absorption Bed Width Dear Onsite Services Engineer: The area available for a septic system on Lot 1 is limited by several factors including the presence of groundwater, location of wells on this and surrounding lots and the placement of the house and driveway. An absorption bed must be placed to insure the separation from groundwater can be met. The width of the bed must be 24' at the south end and 12' at the north to provide the necessary absorption area to meet the design. The ordinance governing septic systems states the bed width can be greater or lesser than 15' with approval from the department. We hereby request that approval. The bed will be accessed with a pressure distribution system. Effluent will therefore be dispensed uniformly over the area. In addition, the subsurface soils are very good for the treatment and disposal of effluent. A minimum of .5' of drainfield rock will be placed. A bed width as noted above and shown on the Site Plan will not adversely affect the operating characteristics of the absorption system. Sincerely, /J Michael E. Anderson, P.E. 1 49th MICIIAEL E. ANDERSON C D *2 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766(FAX) April 9, 2016 Municipality of Anchorage Development Services Department Building Safety Division 4700 Bragaw Street Anchorage, AK 99507 Attention: Plan Review Engineer On -Site Water and Wastewater Subject: Lot 1, Horizon Estates Subdivision Foundation to Absorption Bed Waiver Dear On Site Engineer: The house foundation wall on Lot 1 Horizon Estates Subdivision varies from 4' to 6.5' from the edge of the proposed absorption bed. The attached drawing illustrates the absorption bed and its location in relation to the house foundation. The influence line of the footing and foundation when projected down at a 1:1 slope remains well below the bed and does not encroach into the absorption bed area. It is unlikely that the location of the bed will have any influence on the foundation. We hereby request a waiver be issued allowing the absorption bed to be 4' from the foundation wall at its closest point. Sincerely, � a � _ Michael E. Anderson, P.E. 49th •••i MICHAEL E ANDERSON I Nn C -41R1 C, o -;tz HORIZON ESTATES SUBDIVISION LOT 1 FOUNDATION TO ABSORPTION BED WAIVER SCALE 1" = 3' Ad by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate' of On -Site; Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of betlrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water_ 'supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson'Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 En ineer's Printed Name Michael E. Anderson, P.E.Date 4127116 9 .Qr, .... r�P /� s���, W �4 A'* 49TH 01 6. DSD SIGNATURE _System #1 Approved for bedrooms /••• •••••••••:,,.�� •••• aMICHAEL E. ANDERSON •. System #2 Approved for _ r bedrooms �♦ ��•• GE -4383 Disapproved .. ®Dpseas w• �. O $QOFESStb�ps� Conditional approval for bedrooms, with the following stipu��uWZ-.%:%- If more than t septic system is on the lot: COSA Checklist # _of em _ Structure served by this syst Certificate of On -Site Systems Approval Checklist Legal Description: Horizon Estates, Lot 1 Parcel ID: 051-324-31 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (YIN) Y Date completed 10/3/15 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 64 ft. Cased to 61 ft. Casing height (above ground) >18 in. FROM WELL LOG AT INSPECTION Date of test 10/3/15 Static water level 18 Well production 5 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 4/04/16 Collected by: Anderson Engrg. B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEP/Steel Date installed 4/19/16 Tank size 1,250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA Date installed 4/19-22/16 Soil rating2 .5 GPD/SF Bed (g.p.ci./ft or ftz/bdrm) System type Length 65 ft. Width 12 - 24 ft. Gravel below pipe .5 ft. Total depth 2 - 3 ft. Eff. absorption area 1,000 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fall) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. N Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION Date installed 4/19/16 "Pump on" level at 42 in. Datum Bottom of Tank E. SEPARATION DISTANCES WELL ON LOT TO: Size in gallons 250 "Pump off" level at 38 Cycles tested 2 Septic tank/lift station on lot >100, Absorption field on lot >100, Public sewer main >75' Sewer /septic service line >25' Animal containment areas >50' SEPTIC/HOLDING TANK ON LOT TO: >5' Building foundation Property line >5f Absorption fiel Water main >10, Water service line >10, Surface water Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line •5 Building foundation >10 Water main Manhole/Access (Y/N) _ in. High water alarm level at Y 44 in. Meets alarm & circuit requirements? Y On adjacent lots >100, On adjacent lots >100, Public sewer manhole/cleanout >100, Holding tank >75' Manure/animal excrete storage areas >100, d >5' >100, Water Service line >10 Surfacewater >100, Driveway,parking/vehicle storage >101 Curtain drain None Noted Wells on adjacent lots >100, F. COMMENTS **See Lot Line Waiver. G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 2/23/16 COSA brown sheet 10-10-12.doc .. E. ANDERSON: -4381 �.. a w I M J w J J � m J ^ / g / t N to U cz F I I U, g Q � o a a v' t i I w a a D to O U U Uol S F- m Q W W 70 (N g to N a. N i R 00r Zo ai l r t 2 0 c me° y�Uty� 55.5 X45 I LLJ LJ 9e0;._6 21.8•` t' 0. O N 8�Fcp 3 w ° m -o m I O o a o m Z m E a L! m dh- ..m OC — W vo mm c c a C o°htom p ac ` o mm' El CL g a o M. MQ� N v 1. FALL-: Q dpt �0�0000� Y n r t 2 0 c mome .c cC4.0-E'v me° o C C44 ° 9e0;._6 C ;' 0. O h o z P c w ° m -o m �' o a o m Z m E a L! m dh- ..m OC — W vo mm c c a C o°htom p ac ` o mm' a v401 l E � 5. .0 a 0.0 0HN u. 0 46 C cm o m°�� c£a o m o o n n a m ma E m m Ln 00 m O Q c c 444 m o e CJ ��> am= •r m r t 2 0 c mome .c cC4.0-E'v me° 11 ~-L Cr o C C44 9e0;._6 C ;' .t-�CmoJ3m OO j,OpC—ES v w ° m0 Cc.00 I -o m �' o a o.Cz p N 0 c E T L; o�..°a°ECogra tNoC.0E ..m OC — W ° °zrO.•v a a p ac ` o EMmc0co :m=wE a �g0cE-E a c m m 0 s <3cao C ..-a