HomeMy WebLinkAboutGOULD LT 1Gould
Lot 1
#050-273-41
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP161143
Tax Code Number: 05027341000
Work Type: Septic Initial
Permit Effective Dates: June 20, 2016 to June 20, 2017
Design Engineer: ANDERSON ENGINEERING
Subdivision: GOULD
Site Legal Address: GOULD LT 1 G:0052
Owner/Address: ADAMS KENNETH A & AMANDA L
17040 FOOTHILL AVE EAGLE RIVER AK 995778145
Site Mailing Address: 17030 FOOTHILL AVE, Eagle River Lot Size in Sq Ft: 49467
Total Bedrooms: 5
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Receivec
Issued B)
Cui reVi" 4he dtvo\`AP`()ld..1411
rm wlot
rare )(1 ja?r^fd. 1 m > } vtk � "� C- h ✓`e pr'
MUNICIPALITY OF ANCHORA
MAY 31 2016
Community Development Department Phon ' 7-343-7904
Development Services Division Fax: - 5
On-Site Water & Wastewater Program 1 6 9
ON-SITE SEWER/WELL PERMIT APPLICATION
O<vo-
Parcell.D.4469`273-41
Property owner(s) Kenneth and Amanda Adams
Mailing address 17040 Foothill Drive Eagle River, AK 99577
Site address
Same
Legal description (Sub'd., Block & Lot) Gould, Lot 1
Day phone 350-0603
Legal description (Township, Range &.Section)
Lot Size 49,467 Sq. Ft. Number of Bedrooms Five (5)
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field E]
Initial 0 Single Family (SF)
El
Septic Tank ElUpgrade
(w/wo ADU)
❑
Duplex
Duplex (D)
El
Tank El
Renewal El
Dwellings
❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES
A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information
is correct. I further certify that this is in accordance with
applicable Municipal Codes.
li^DDTT
(Signature of property owner or authorized agent)
Permit/Rush Fees: 155 4 Waiver Fees:
Date of Payment: (0-1—A0 Date of Payment:
Receipt Number: 0581�(A Receipt Number:
Permit No. oe2PI (,PUL0 Waiver No.
Permit App_9-1-12.doc
C0.1
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 " 677-7766 FAX
May 31, 2016
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 1, Gould Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 1, Gould Subdivision intends to construct a new five -bedroom home
on the lot. We are therefore requesting a permit be issued for the construction of a new
septic system to accommodate the home. An existing Class C Well is located on the
P11trtor-twhich will remain in service. The attached Site Plan and backup documentation
Pidentify the location and configuration of the existing well and proposed septic system
along with the alternate site. The existing septic system on the lot will be
decommissioned in accordance with Municipal Code. Also identified on the plans are
the existing wells and septic systems on surrounding lots. No conflicts exist between the
proposed septic system and existing well or septic systems and wells on adjacent lots.
Drainage arrows are shown on the site plan showing the grade and direction of flow on
the lot. The drainage pattern will not be changed as a result of this project.
A test hole was placed on the lot in the area of the absorption trench and alternate site.
The logs indicate poorly graded sand with some gravel (SP) in the zone specified for
the absorption trench. The percolation rate of the soil was determined to be 1 to 2
minutes per inch. A test hole placed in 2007 indicates similar results but with a
percolation rate faster than 1 minute per inch. No groundwater was found during the
placement of the test hole and none developed during the monitoring period. An
application rate of 1.0 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,500 -gallon septic tank and and
a 75' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 2' below the surface and the total depth will be 6'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the
septic tank.
Lot 1, Gould Subdivision ,e,
May 31, 2016 C 01
Page Two
The ground surface on the lot in the area of the septic system slopes to the northwest.
The new trenches will be constructed parallel with the contours of the slope as much as
possible in conformance with Municipal requirements. The new septic system will be
constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
Lot 13
,,Lot 16
Existing
ss C Well
FOOTHILL AVENUE
�115' TELEPHONE & ELECTRICAL EASEMENT
C
� 75 Long x 5 Wide x
4'-Effective_De h--'
/,Absorption Trenh .
MT
1,500 Gallo,
Septic Tank
r/ , Oc
G
10
v Ex
- �THSS
Five Bedroom
Home
JuI
LOT 1
GOU41) SUBDIVISION
1 49,467 SF
ExistinggI�
Class C Well
�\ 5
a \ 0 �
i
U�
\
\
\
— — — — — — — — — — — — — — —
O
Existing
Septic
Lot 2
Lot 17 /
1 /
/
1 /
1 /
I '
I r'
I '
r
I r
I '
I �•
---t
SITE PLAN
SCALE 1° = 50'
LGN
THSS - Test Hole S&S
SV - Septic Vent
CO - Clean Out
FCO - Foundation Clean
MT - Monitor Tube
2CO - Double Clean Out
0
\
\
Out \\
�1
/\
MICHAEL E. ANDERSON
No. CE -4361
�
/ r
/
1
/
NOTE:
1
Decommission Existing Septic
System in Accordbnce With
II
Municipal Code,
No Conflicts B¢tween Proposed
I
Weeps i syhem�ea. Existing
1
No Excessive (Slopes within 50'
I
or Surface W8ter
within 100'
rl
of Proposed teptic System.
r
r
1
1
r
t
Lot 17 /
1 /
/
1 /
1 /
I '
I r'
I '
r
I r
I '
I �•
---t
SITE PLAN
SCALE 1° = 50'
LGN
THSS - Test Hole S&S
SV - Septic Vent
CO - Clean Out
FCO - Foundation Clean
MT - Monitor Tube
2CO - Double Clean Out
0
\
\
Out \\
�1
/\
MICHAEL E. ANDERSON
No. CE -4361
LOT 1, GOULD SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Five Bedroom Home 5' Wide Trench System
Perc. Rate: 2 Min./Inch 1,500 Gallon Septic Tank
Application Rate: 1.0 GPD/SF 4' Drainfield Rock
5 Bedrooms ' 150 GPD/Bedroom = 750 SF Absorption Area
750 SF/1.0 GPD/SF/5 SF (Width) *.5 (Red. Factor)= 75 LF Trench Length
THEREFORE: Construct a 75' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be
6' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
5'
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Private Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: Lot 1, Gould Subdivision
PERFORMED FOR: Amanda Adams
DATE: 5/10/2016 PROJECT No.:
PARCEL ID#: TECHNICIAN: W Roberts
DEPTH TEST HOLE 1
(feat)
I OB/OG
2
3
4
5
6 SP/SM
7
8
9
10 WAS GROUND WATER ENCOUNTERED? NO
1F YES @ WHATDEPTH? 0
11 DEPTH OF WATER AFTER MONITORING: None
17DATE OF MONITORING: 5/17/16
__-
1
SITE PLAN
See Site Plan
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
5/10
TEST HOLE PRESOAKED PRIOR TO TESTING:
1
1:16/1:26
10
0.25,/7.50"
7.25"
2
1:27/1:37
10
0.50"/7.75"
7.25"
3
1:38/1:48
10
0.25"/7.50"
7.25"
4
1:49/1:59
10
0.50'/7.75"
7.25"
5
2:00/2:10
10
0.38"/7.88"
7.25"
6
2:11/2:21
10
0.25"/7.50
7.2511
PERCOLATION RATE: 1.4 (MIN/INCH) PERC. HOLE DIA.--L--(INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 6/10/16
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page of
www. ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: :~f~O~OO.,~-7 PID Number: O;~O-~.-'/~
Name:~...~ Ol~.l'~,~k. ~--------.'~0 O'[ ~ WastewaterSystem: [] New ~'Upgrade
Address:
11~0[ ~e¢~.,.~ ~¢ u ~&¢~ q~ ABSORPTION FIELD
Phone: Number of Bedrooms:
~0--~5~ & ~ Deep Trench Shallow Trench DBed ~Mound ~Other:
LEGAL DESCRIPTION So, Rating: ~' O GPD/Ft2: Total Depth from o~nal grade; Ft.
Block: Lot: ~ Subdivision: Depth ,o pipe bottom from origin~de: Gravel depth bene~pe:
Ft. Ft.
Township:~ Range: 2~ So.ion: t~ Fill added above original grade: GravelLength:
0' ~ Ft. ~ Ft.
Well: ~ New ~ Upgrade ~v~ width: ~ Ft. Number~of lines: ~Distance between lines:Ft.
Class~(Private. A. B. C): Total Depth: Ft. Cased to: Ft. [ Total absorption area: ~ Ft2 ~T~Pipe Material:
Dri~ ¢] Date Drilled: Static Water Level: Installer:
Yield:~ump Set at: Ft. Casing Height Above Ground:
~"~1 ~,. TANK
SEPARATION DISTANCES ~Septic ~ Holding ~ S.T.E.P. ~ Qther:
T~ Septic Absorption Lift Holding )ublic/Private M~n~acturen Capacity:
Tank Field Station Tank SewerLine ~C ~]~ ~]~S ~ ~ t ~00 GaL
Well ¢~ , ~ ~1 ' ~5 /+ Material:~E Number o,~Compa~ments:
SuCaceWater ~ ~ ~1~ ' ~ / ~ LIFT STATION
Lot Line ~,~ ~1~ ~ Size; ~ MaRufacturer:
Foundation 5f+ lO' * /1 "Pump o~" ,evet at: * ¢'~-'% in.II High water alarm at: in.
Cu*ainDrain , ~*~ ~ '~ / t ~ Electrical lnspectionspedorme~
Remarks:
BENCH MARK
Location and Description:
~ ~0~ O~ ~ O~ Assumed Elevation:
Inspections pe~ormed by: !~1 ~. ~f~ ~. ~d, Dates: 1 ff/~
Conditional Approval Date:
Reviewed and approved by' Date. ~ ~
PERMIT NO. SW080057 PAGE 3 OF 4
bdunimipaki~sy o¢ Anchonage
DEVELOPMENT SERVICES DEPARTMENT - BUILDING SAFETY DIVISION
ON-SITE WATER AND WASTEWATER PROGRAM, &700 BRAGAW STREET
P,B, }Box 196650 I anchoro9e, ALoska 99519-6650 t Tetephone,, (907) 343-7904 ·www,ci,oncho~-(~9e,(~k,us
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL T1 4N R2W SEC 12 LOT 12 P.I.D. NO. 050--273--07
PERMIT NO. SW080057 PAGE 2 OF 4
PluniciF~cLi~y oF Ancho~cge
DEVELOPMENT SERVICES DEPARTMENT - BUILDING SAFETY DIVISION
ON-SITE WATER AND WASTEWATER PROGRAM, /-,700 BRAGAW STREET
P,D, ~}ox 196650 t Anchora9e, /~ska 99519-6650 I Te~ephone~ (907) 343-7904 ·www,ci,enchorage,al<,us
ON-SITE WASTEWATER DISPOSAL SYSTEPI AND/OR WELL INSPECTION REPORT
LEGAL T14N R2W SEC 12 LOT 12 P.I.D. NO. 050--275--07
?ERMr? NO. SW080057 ?^CE 4 07 4-
MunicipcxLity oF Anchomege
DEVELOPMENT SERVICES DEPARTMENT - BUILDING SAFETY DIVISION
ON-SITE WATER AND WASTEWATER PROGRAM, /-+700 BRAGAW STREET
P,B, ]3ox 196650 I anchoeage, Ataska 99519-6650 ®le~ephone, (907) 343-7904 ·www,ci,anchor'age,ok,us
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
ggaAg T14N R2W SEC 12 LOT 12 P.I.D. NO. 050--275--07
FINAL GRADE% ST1 ST~...-96.1
F1 - /-2" INSULATION
TOP OF ,TANK~[ ........................... ii.......7. ....
SEPTIC TANK ~
ORIGINAL
A B
FCO 4.5' 20.5'
CO3 84.0' 65.5'
TMT 1,.58.0' 123.5'
ST1 141.0' 126.5'
ST2 145.0' 130.5'
DBL1 148.0' 133.5'
DBL2 149.0' 134.5'
C01 178.5' 162.0'
MT1 170.0' 154.0'
C02 148.0' 136.5'
MT2 150.5' 137.5'
FINAL GRADE~,
GRADE~
95.6
V/Ill/
MT1 =89.6'/
MT2=89.6'
C01 =96.2'
[.~C02=94.7'
"fNSULATfON
C01 =92.6'
C02--92.6'
NO
·
WATER FOUND
77.7' B.O.H.
ENG
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 09519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: May 23, 2008
Expiration Date: May 23, 2009
Permit Number: SW080057
Legal Description: T14N R2W SEC 12 LOT 12
Design Engineer: 0003 S & S ENGINEERING
Owner Name: DONNA GOULD
Owner Address: 11801 OLD SEWARD HWY
ANCHORAGE, AK 99515-
Parcel ID: 050-273-07
Site Address: 17040 FOOTHILL DRIVE
Lot Size: 108900 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] DisposalField [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DaD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:.
Issued By:.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
_ · · www.muni.orglonsite
lSl'l: (go7)34,.7904
~'~ ON-SITE SEWERJ~NELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
- V3-o'7
Pro p e rty owne r(s) c"~,~),~,~
Mailing address H~/ ~) ~
Site address /?OqD ~~ ~,~E
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
Lot Size /0~ q~ Sq. Ft. ~
Day phone
Zip Code __
Zip Code
Number of Bedrooms
THIS APPLICATION IS FOR (~:~ all that apply): THIS APPLICATION IS AN:
Absorption Field '{~ Initial []
Septic Tank [~ Upgrade ~
Holding Tank [] Renewal
'D
Priw []
Private Well []
Water Storage []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
PermitJRush Fees:
Date of Payment:
Receipt Number:.
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number.
May19,2008
ROBERT C. COWAN, P.E.
CML ENGINEERS
(9O7) 694-297g
FAX (907) 694-12
MUNICIPALITY OFANCHORAGE
Development Services Department
P.O. Box 196650
Anchorage, AK99519
REFERENCE: Lot 12; Section 12; TI4N; R2W; S.M.
It is requested that you issue a permit to install a ne~v septic system to serve the
existing storage building with a bathroom on the referenced property.
A test hole was excavated and a pemolation test performed. The approximate location of
the test hole is located on the attached site plan. At the time of excavation (2/12/2008)
water was not found. After seven days of monitoring, no ground water was found.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
Ifyou require additional information, please contact us.
Sincerely,
Enclosure
15681 S. Blrchwood Lp. Rd.- Chuglak, AK 99567
25' ACCESS DRIVEWAY
/I
NOI$30
NY]d-4115
Mu,lclpallly of Anchorauo
Developme,I Se~vlces Deparlmeid
I]utkll,g Safely Dlvhlol~
P.O. Uox 196650 Anchorage, AK 90519 6050
(907) 343-7~4
~--~Soils Log - Porcolation Test
- Sp
13-
14-
t5-
16-
I?-
10-
20-