HomeMy WebLinkAboutRAPTORS KNOLL LT 3Raptors Knolls
Lot 3
#017-101-60
Permit Number: OSP161163
Tax Code Number: 01710160000
Work Type: WellSeptic
Permit Effective Dates: June 21, 2016
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to June 21, 2017
Design Engineer: ANDERSON ENGINEERING
Subdivision: RAPTORS KNOLL
Site LegalAddress: RAPTORS KNOLL LT 3 G:3037
Owner/Address: WINFREE MICHAEL ALEX &
PAULA JEAN 3504 VASSAR DR ANCHORAGE AK 995080000
mrtment
Site Mailing Address: 14093 RAPTORS KNOLL CIR, Anchorage
Lot Size in Sq Ft: 54066
Total Bedrooms: 5
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Si~ Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
tjS¢~ O PERMIT APPLICATION~ UBMITTA
~SlTE SEWER/VVEL~ I,/ JUN ! ? ~016~ ~'
ParcolI.D.017-101--6' __ i RUSH!
Property owner(s) Harding Homes of Alaska, Inc. ~ay phone 350-1860
Mailing address 5771 Heritage Heights Drive Anchorage, AK 99516
Site address 14070 Raptors Knoll Circle Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Raptors Knoll, Lot 3
Legal description (Township, Range & Section)
Lot Size 54,075 .Sq. Ft. Number of Bedrooms Five (5)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
([~ all that apply)
Absorption Field [] Initial [] Single Family (SF) []
(w/wo ADU)
Septic Tank [] Upgrade []
Duplex (D) []
Holding Tank [] Renewal []
Multiple Dwellings []
Privy [] (SF and/or D)
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_9-1-12.doc
ANDERSON ENGINEERING J
p,O, BOX 240773
~NCHORAGE; AK 99524
5227773 ~77,7766 (FAX)
June 16,2016
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage. AK 99519-6650
Subject:
Lot 3. Raptors Knoll Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 5. Raptors Knoll Subdivision intends to construct a five bedroom
home on the lot. We are therefore requesting a permit be issued for the construction of
the well and septic system to accommodate the home. The attached Site Plan and
backup documentation identify the location and configuration of the proposed well and
the proposed septic system along with the alternate site. Also identified on the plans
are the existing wells on the lots surrounding this lot. No conflicts exist between the
proposed septic system and well or septic systems and wells on adjacent lots.
Drainage arrows and slope surface contours are shown on the site plan showing the
grade and direction of flow on the lot. The drainage pattern will not be changed as a
result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated silty gravel with sand (GM). The percolation rate of the soil was determined to
be 6 to 15 minutes per inch. No groundwater was found during the placement of the
test holes and none developed during the monitoring period. An application rate of .8
gallons per day per square foot was used in the design of the absorption system. We
are proposing to place a new 1.500-gallon septic tank with an absorption trench 60'
long x 3' wide x 8' effective depth. The elevation of the distribution line in the
absorption trench will be 3' below the surface and the total depth will be 11'. A
minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption
trench and 4' over the septic tank.
The ground surface on the lot in the area of the septic system is neady flat with slight
slopes to the southwest at a shallow grade. The new trench will be constructed parallel
to the contours of the slope as much as possible in conformance with Municipal
Lot 3, Raptors Knoll
June 16, 2016
Page Two
requirements. The new septic system will be constructed a minimum of 100' from all
wells and any surface water and 10' the proposed and existing water services in the
area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
........ ~o' u~ ~. __~_ ............ - .........
/ t ~ I
o I
< I
EAST 142ND AVENUE
LOT 3, RAPTORS KNOLL SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Five Bedroom Home Deep Trench System
Perc. Rate: 6-15 Min./Inch 1.500 Gallon Septic Tank
Application Rate: .8 GPD/SF 8' Drainfield Rock
5 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 937.5 SF Absorption Area
937.5 SF/16 SF/LF = 58.59 LF Trench Length
THEREFORE: Construct a 60' Long x 3' Wide x 8' Effective Depth Absorption Trench atthe
Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth
to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption
Trench. Maintain 100' Separation from Wells in the Area.
Natural
Backfill
Geotextile
-- Fabdc
4" Perforated
PVC (Holes Down)
Drainfield Rock
TYPICAL DEEP TRENCH SECTION
NOTE Grade Area Over Trench to Dra~n Away . ~
.
Minimum 6' Separation F~m Bedrock. ~....~;.~.~h......~..
M n mum 4' Separation From Groundwater ~ ~'~"~"'~' ~"~]~"~
....... , ~ . , - ~..;.....~.....,~
i~lnl~u~ 1uu ~epa~tlon From Wells In the Area. ~ MIONAELE. ANDER~N
Minimum 100'Separation From Sudace Water or Streams. ~:~,~ No.
4700
DEPTH
(~¢0
1
2--
3--
4--
5--
6--
7--
8
9
11
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LOT 3, RAPTORS KNOLL SUBDIVISION
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 6/7/16
PARCEL ID#:
HARDING HOMES. INC.
PROJECT No.:
TECHNICIAN:
TEST HOLE A ]
OB/OG
SILTY GRAVEL
WITH SAND
WAS GROUND WATER ENCOUNTERED?
IF YES ~ WHAT DEPTH9
DEPTH OF WATER AFTER MONITORING:
W. ROBERTS
SLOPE
NO
DATE OF MONITORING: 6/16/16
BOH @ 18'
SITE PLAN
SEE SITE PLAN
TEST HOLE PRESOAKED PRIOR TO TESTING:
6/7 1 5:14 2.13"
2 5:44 30 5.38" 3.25"
3 5:45 2.25"
4 6:15 30 5.50" 3.25"
I 5 6:16 2.00"
' I6 6:4630 5.25",3.25"
PERCOLATION RATE: 9.2 0VliNflNCH) PERC. HOLE DIA. 6" _¢NCHES)
TEST RUN BETWEEN: 4.5 FT. and 5.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE. 6/16/16
Municipality of Anchorage
Development Services Department
BuiJding Safety Division
On-Site Water and Wastewater Program
4700 Eimore Road
P.O. Box 196650 Anchorage, AK 99507
www.ci, anchor aqe.a k.us
(907) 343-7904
Soils Log - Percolation Test
Performed For: Ray Hi~kel
LegaJ Description: Timber Trail Subdivision, Lot 3
Slope
I
Date Performed: Feb 8,
Township, Range, Section:
Site Plan
WAS GROUND WATER
ENCOUNTERED?
F YES, AT WHAT DEPTH? L
Depth to Water After O
Monitoring? 0 ~J I~ E
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
Reading Date Gross Time Net Time Depth to Water Net Drop
PERCOLATION RATE ,.~ (minu~es/inch) PERC HOLE DIAMETER
TESTRUNBETWEEN ~,~ FT AND ~.~" FT
COMMENTS Perc Cavity was presoaked
PERFORMED BY: A. Harala [ CERTIFY THAT THiS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNiCiPAL GUIDELINES iN EFFECT ON THIS DATE. DATE:
Municipality of Anchorage ~,~....F,.b~'~ ..S~..~,~,}.
H Development Services Department ·
On-Sire Water4700 E{moreand WastewaterRoad Program /
Soils Log - Percolation Test , ,,
Pe~ormed For: mckel Date Pe~ormed: Feb 8, 201~
Legal Oesori~iJon2 Timber TmiJ SubdMsion, Lot 3 Township, Range, Sec[bn:
Slope S{te Pman
WAS GROUNDWATER
ENCOUNTERED?
F YES, AT WHAT DEPTH?
Depth to Water After
Monitoring? J~J~ ~'
Reading Date Gross Time Net Time Depth to Water Net Drop
PERCOLATION RATE I I (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN +~'FT AND ~1~"'~ 0 PT
COMMENTS Perc Cavity was presoaked
PERFORMED BY: A. Harala [ CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL. GUIDELINES IN EFFECT ON THIS DATE. DATE: