ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP161156 PID Number: 041-021-75 0 New ❑ Upgrade
Name:
BRIAN MILLER
ABSORPTION FIELD
■ Deep Trench ❑ Shallow Trench []Bed ❑ Mound
Address:
9970 MIDDLEROCK ROAD *ANCHORAGE, AK 99507
❑ Other
Phone: No. of Bedrooms:
Soil Rating:
Total Depth from original grade:
231-5828 4
0.8 GPOSq Ft.
*10 (MAX.) Ft
LEGAL DESCRIPTION
Depth to pipe invert from original grade:
Gravel depth beneath pipe:
SEE DWG. a
7.0 Ft
Subdivision: Block: Lot:
Fill added above original grade:
Gravel length:
HILLSIDE NORTH #7 5 1
SEE DWG.
55
F<
Ft.
Township: Range: Section:
Gravel width:
Beds Number of lines:
Distance between lines:
2.5 FL
-
- Ft.
SEPARATIONDISTANCES
Total absorption area:
750+
Number of trenches:
-
Dist. between trenches:
-
To
Septic
Absorption
Lift
Holding
Public/Private
From
Tank
Field
Station
Tank
sewer Lines
90. R
Ft.
Well
100'+
100'+
-
254
TANK N Septic ❑ S.T.E.P. ❑Holding ❑Other
Manufacturer.
Capacity:
Surface Water
1004
1004
-
-
ANCHORAGE TANK
1250
N/A
Gal,
Lot Line
5'+
104
-
-
Material:
Number of compartments:
STEEL
2
LIFT STATION
Foundation
10'+
104
-
Manufacturer:
C
Gal.
Curtain Drain
NONE KNOWN
Remarks: SEE ATTACHED LETTER REGARDING INSPECTIONS
'Pump on" level at
"PumpofNlevelac
High water alarm at:
SEE ATTACHED SLOPE WAIVER REQUEST
Pump Make & Model
77 1
Electrical Inspections performed by:
PIPE MATERIAL
House to tank D3034 Tank to D3034
drainfield
Installer WILCO EXCAVATION
Drainfield D3034 CO/MT D3034
Inspector GEG, Ltd.
BENCH MARK (Assumed elevation)
100.00 Ft.
Inspection
Location and Description:
Dates: 1st 7-13-2016 2nd 7-14-2016
3rd - 4th -
BOTTOM OF TRIM AT SW CORNER OF HOUSE
ENGINEER'S SEAL
Community Development Department Approval
.� SF `A� J.
w444
41,
Conditional approval: Date: Zz 17 6
°•:Y ��
Al
0 . .... .... 0
0
./ .. ;.•.........................4: •. 10
y rn ss �: �
CE 795 AV
Approved: Date:
��FESS���:•�
LICENs! ,11 \��L��
#AECC884
Incna�linn RnnnA 1_1_t�Ann
Engineer:
Legal Description
Parcel ID:
Permit:
Report Type
Municipality of ch®rage
On -Site Water and Wastewater Program
P.O. Box 196550 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
Review Comments
GARNESS ENGINEERING GROUP LTD
HILLSIDE NORTH #7 BILK 5 LT 1
04102175000
OSP161156 WellSeptic
As Built Review
11/13/2019
Completed By: R.Carroll
The application has been reviewed and the following comments have been generated. These are to be satisfactorily
addressed prior to MOA approval:
As -built survey originally submitted was dated 7/25/19, but was not printed to scale. The survey that was submitted
with the resubmittal was dated 5/31/19 and is missing standpipes. Please provide a to -scale as -built survey with all
standpipes identified to match the record drawing. %Z .$ D L vim_ C)
2. According to the photos provided, the septic tank is not adequately protected from traffic. Either additional barriers
need to be provided or calculations submitted to demonstrate the structural integrity of the tank, accounting for the
potential that a vehicle could be parked over it.
3. Please address the structural stability and protection of cleanouts/monitoring tubes for the drainfield located in the
driveway.
/�-o D 0-,(-S.S
C C)SA
C-
t z7-/2-to
0
L 1 ``'` _tee •:-_•�zh--° �' ` - - - 5= ' p: r �" - _- _
1
TY'"'`e � � �s Fi i' J• -��z 1 �':( � 'F.-F<� ���L \l� �S ti Y, ,<.. �r
c.� K y� 'ti,. ..r 'Y ? c ♦��`f{ lit 1\- -
wJ'C'11, �{'P •rf�, r ��$'! t �pq. :Y4'
. 'S-1 .. . a' Y.`�(4�• .� �3' �'�s�ii�`Y tL�a.uC rj - �� " `4.��iY�AI •y`�c �.l'►1. - - • . �,�i� �� ���' S�`:.:`�eS�y� � .-1.
ml
to
W
- ' f , , !A'�"
, -'z ,, ". ' I Ml u
100' WELL RADIUS
APPROXIMATE LOCATION
OF WATER SERVICE LINE
PER CONTRACTOR
A.
7n.
THE RESERVE DRAINFIELD WILL
NEED TO BE THE EXISTING
DRAINFIELD RE -BUILT OR NEW•TESTHOLES PERFORMED TO THE .16
WEST OF THE PROPERTY. 's
NEW DRAINFIEL
oc,
C0 -MT
NEW 4 BEDROOM
B HOUSE
'.+T H # 1
DBL1 & DBL2
TiCO
C
NEW 1250 GALLON
STEEL SEPTIC TANK
A-41 A IV, f14 cl
GARNJVJ�513 ENGINEERING G"RIC)OUPLtd
CIVIC. & ENVIRONMENTAL ENGINEERS ,
3701 F MAW RWD. SWE 101 0 ANCHORWL AK 99507 PWK W-0179 - FAX (907) WEBSrrFwaw
-
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
BRIAN MILLER (907)231-5828 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
HILLSIDE NORTH #7; BLOCK 5, LOT 1 PNB
TYPE OF WORK: DATE:
._ SEPTIC SYSTEM RECORD DRAWING 11 /A / 1 q(RFviRFr)
"i "1111111PIIIIIII
FCO
62.8
47.6
25.8
ST1
-
31.4
67.7
ST2
-
26.2
75.4
DBL1
-
25.0
77.1
DBL2
-
24.7
77.9
C01
39.8
20.9
-
MT1
32_220.3
jr2
135.9
1 66.2
1119.21
1 MT2 135.3
165.8
1119.01
A
Si:
QFJ
e
.......... . ................
....... .... ; .... 0
s Q5 m �yafrne
1P �•fill, 1,7 AV
4•
1�71 or
.............. !�,\, 4W
a—itIFESS
IN YA TA I
PERMIT NUMBER: OSP161156 RECORD D RAW I N G
SEE ATTACHED ENGINEERING LETTER
REGARDING ELEVATIONS
FINAL GRADE = 98.82-98.83
TOP OF TANK ST1 ST2
AT INLET = 92.32 TOP OF TANK
/ AT OUTLET = 92.33
INVERT OF BUNG / I
I NEW 1250 GALLON I
I IN OUTLET = BUNG
AT INLET = 91.89 SEPTIC TANK INVERT OF BUNG
MT CO FINAL GRADE = 99.43-99.69
ORIGINAL GRADE @
HIGHEST POINT = 88.86
\� FILTER FABRIC
INVERT OF PIPE = 85.92 - 85.89 PER
ELEVATION SHOT IN THE C/O
7.0+ FEET (PER GEG
INSPECTION REPORT)
PARCEL ID NUMBER:
041-021-75
4 OF TRENCH = 78.86-79.09 PER ELEVATION
SHOT AT THE BOTTOM OF THE MTS
RELATIVE ELEVATION @ BOTTOM OF T.H. = 72.86(T.H. DRY ON 5/24/16)
CIVIL & E N V I R 0 N M E N TA L ENGINEERS
3701 E. TUDOR ROAD, SUITE 101 . ANCHORAGE, AK 99507 - PHONE (907) 337-6179 - FAX (907) 338.3246' WEBSITE: www.gamessengineenng.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
BRIAN MILLER 231-5828 3 OF 3
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
HILLSIDE NORTH #7; BLOCK 5, LOT 1 D.J.G.
TYPE OF WORK: DATE:
PROFILE DRAWING 6/20/2019
li
Municipality of Anchorage "A6
I h•purnncnt
P.O. Box 196650 0 4700 Elmore Road
Anchorage Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Department
On -Site Water and Wastewater Section
X*X* VARIANCE/WAIVER Xx*X
Waiver#: OSV191091 COSA#:OSC191336 Permit#:OSP161156
PI D#: 041-021-75
Legal Description: Hillside North #7 Block 5 Lot 1
Engineer: Garness Engineering Group
Applicant: Brian Miller
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the excessive slope has been approved. The approved separation distance is 0.0 feet. See
engineer's waiver request for justifications.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on -
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
Date: c2(� I Approved by:
Name of Reviewer
November 4, 2019 (REVISED)
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Hillside North #7; Block 5, Lot 1, Waiver Requests
To whom it may concern:
During the installation of the drainfield, the lot was vacant. When our firm was contacted
and informed that the home had been completed, we made another site visit to confirm
separation distances and perform a well adequacy test. During our site visit it had been
discovered that a second driveway had been excavated below the drainfield, creating a
cutbank, and additional fill (approximately 10 feet) had been placed over the drainfield.
This new driveway and imported fill, has created slopes greater than 25% at the
drainfield location. We are now requesting a zero (0) foot slope waiver because of this
development. As can be seen on the attached drawing, at a 25% slope (starting 2.5 feet
above the drainfield) the potential point of daylighting is greater than 50 feet horizontally
from the drainfield.
The orientation of the home and driveway was altered during construction which led to
the tank and drainfield being located underneath the driveway. We are requesting a
waiver for these variances and justifications are as follows; � c e
• The contractor has placed concrete blocks in front of the septic tank to help
prevent any vehicles from driving or parking over the tank.
• It is likely that because of the placement of the concrete blocks, snow removal
over the tank is unlikely which will help prevent any freezing. It should also be
noted that the tank has 6.5 feet of cover.
The drainfield has approximately 14 feet of cover and is unlikely to experience
aes.
., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
.J/-
Jung, 2019
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Hillside North #7; Block 5, Lot 1
To whom it may concern:
The subject lot septic system was designed and installed in 2016. The septic system
was inspected by Garness Engineering and installed by Wilco Excavation in July 2016.
The septic tank was later moved and inspected by GEG. Our field notes for the tank
relocation have been misplaced, so the date of this inspection is unknown. During the
installation, there were no permanent structures to serve as a "Benchmark", so a "Nail in
Tree" was used. During the construction of the home, the benchmark (three with nail)
was removed by the contractor; therefore, the elevation control point for the record
drawings/final grading is no longer present. A benchmark elevation of 100.00 was
establish as the bottom of trim at the house corner and all elevation were back
calculated. It should be noted that GEG still has our field notes for the drainfield
installation and the original tank installation; therefore, we know the system was
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
lfel ime t Services Diepartnerzt
Suilding Safety Division
t
l on-sfte Water & Wastewater pr r xnn
-fir;00 Eitiioic fiGtid
P.O. -po% 196650 Anchorage, AK 99507
Mark Begich SA r r Yssts e.m23tti.t2 Jon i�€
Mayor _
(90'7) 3 43-790
Well Log
Permit Number-:OSPI61156 Date of Issue: tune 28, 2016
Date Started: 8-19-16 gate Completed: 8-24-16 Is well located at approved permit location? Ix I Yes L j No
Legal Description: Hillside North #7 block5 lotl G:2043
Property Owner Name & Address: Brian Miller
8580 Brookridge Dr
Anchorage, AK 99504
Borehole Data:
Soil Type, Thickness & Water Strata
Depth
From
(ft)
To
Method of Drilling W air rotary 0 cable tool
Casing type: steel
�
Wall Thickness: .250 inches
Diameter: --_ 6 inches Depth: 28 feet
Liner Type: PVC
Diameter 4.5 Inches Depth: 20' - 300`
Casing stickup alcove around: 2 feet
-
stickup
0
2
sift w( gravel
2
18
silt wl rock N
18
28
bedrock
28
300
Static water level (from ground level): 17 feet
Purnping level:- _ feet after
hours pumping _- gym
Recovery hate- 4 gpm
Method of Testing: airlift
_._
_
Well Intake Openmg- Type:
n Open End n Xn open Bale
Q screened Start feet Stopped feet
n Perforations Start__._feet Stopped feet
—
t trout Type: nton #? 'a olaalne:grantaleS
20` Start 0 feet Stopped 20 feet
-
—Depth:
Pump: IntakeDepth_ feet
Pump size hp Brand Ni ame
Well Disinfected Upon Completion? nx Yes n No
Method oflDisind'eet onTchlorcne tablets
Comments:grouted 4.5 liner into bedrock per muni
Well Drifter: hefty Drifting, Inc.
3540 Akula Dr.
Anchorage, AK 99516
Water Sample Results:
Arsenic: N 1>
Nitrates- iv `�
Total t_;oliform Bacteria: �8• ._ "
Other Bacteria.
uglL -
L���
colontes(l00mL.w
covloomd.
Attention: The well driller shall provide a well fog to DSD within 30 days of completion.
It"Ievelopment Services txpartnnent
Buildiing Safety Division
. . . . .........
On -Site Water Wastewater Program <
H
A-700 R-norc-Road
P 0. Box 196657,0
Mark Begich
An c: III o, r a 9
Mayor
v., w rn u n i _c.ro./onsi t e
(907) 343-7904
Pump Installation Log
Well Drilling Permit Number: 8W— 05PJG1115 4 Date of issue:
Parcel Identification Number:
—
Legal Description dillydt 1%rA-, -7t 7 Property Owner Name & Address:
K
Pump Installation Date: 1(2- 9-
Pump Intake Depth Below Top of Well Casing:d6o feet
Pump Manufacturer's Name:
Pump Model:, /0 50E /9 - 3 31>
Pump Size i. 7 hp
Pitless Adapter Burial Depth: /0 feet
Pitless Adapter Manufacturer's Name: CC1#VbVt1 k)jo
Pitless Adapter Installer: tj ('I co
Well Disinfected Upon Completion? X Yes F No
Method of Disinfection: CAIDrk;G tt(os
Comments:
Pump Installer Name: (EE�
P.O. BoXLU130
Awhorage, AK99511
Attention: The pump installer shall provide a pufnp installation log to the DSD within 30 days of pump installation.
V)
m ::E
0
V)
C/) 0
m X
K >
rrl 0
Z m
rrl
K
M
Amid
0
0
ca (A
m
0
M
61)
C/)
MO
Zju
Q
m
7,�o
0
0
z
C)
7
.0,
L71
m
0
m
rT
C)
-><
x
Ci
x
m
0
x
Permit Number:
Tax Code Number:
Work Type:
On-Site Water & Wastewater System Permit
OSP161156
O4102175000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: June 28, 2016 to June 28, 2017
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: HILLSIDE NORTH #7
Site LegalAddress: HILLSIDE NORTH #7 BLK 5 LT 1 G:2043
Owner/Address: KREPS KEVIN W & LYNDA L
8580 BROOKRIDGE DR ANCHORAGE AK 995044193
Site Mailing Address:
Lot Size in Sq Ft: 405979
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:~~
Issued
MUNICIPALITY OF
Community Development Department ~,,~ '~//-'~._h_Phone.~.9~2'~3-7904
Development Services ~ ~ 343-7997
On-Site Water & Wastewater Program
Mayor Dan Sullivan
On-Site Sewer/VVell Permit Application
For A Single Family Dwelling
Parcel I.D. 041-02-175
Property owner(s) BRIAN MILLER Day phone 251-5828
Mailing address 7915 PORT ORFORD DR. *ANCHORAGE, AK 99507
Site address NHN MIDDLE ROCK ROAD *ANCHORAGE~ AK
Legaldescription (Sub'd, Block&Lot) HILLSIDE NORTH #7; BLOCK 5, LOT 1
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING:
( [~;~11 that apply) Initial [] Single Family (SF) []
Absorption Field [] (w/wo ADU)
Septic Tank [] Upgrade []
Renewal [] Duplex (D) []
Holding Tank [] Multiple Dwellings []
Privy [] (SF and/or D)
Private Well [~]
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A Distance: -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment: (0 I' h
Receipt Nur ber: C)'5
Permit .o. 0 S P 1 0115 I~
Waiver Fees:
Date of Paymer~:
Receipt Number:
Waiver No.
(Rev. 0~/~)
June 9,2016
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System for Hillside North #7; Block 5, Lot 1
To whom it may concern:
The subject lot is vacant. The property owner is proposing to build a four (4) bedroom
home that will be served by a private well and septic system. We are proposing to install
a new 1250 gallon septic tank and deep trench type drainfield. Two testholes were
excavated on the property and the drainfield is designed around the 30 foot radius of
testhole #2. Comments regarding the design are summarized as follows:
1. SOILS: See the attached 2016 logs which show the soil classifications, groundwater
monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: See the attached 40 scale design drawing which shows
topography. The average topography around the proposed drainfield is 17%. There is a
cutbank towards the west property line, however, the proposed drainfield is >50 feet
away from the cutbank.
We are unaware of any adverse impacts this installation would have on adjacent wells
or septic systems. If you have any questions, please contact us at 337-6179. Thank
you for your assistance.
jeffre/'~/
Presi~'E
I, P.E., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.corn
HILLSIDE NORTH ~7; I~CT C
100' WELL RADIUS DOES
NOT ENCROACH ON THE
PROPOSED SEPTIC SYSTEM
HILLSIDE NORTH ~7; BLOCK 5, LOT 1
1" = 100'
HILLSIDE NORTH #7;
LOT 6
I
\
/
/
NORTH 1~7;
BLOCK ~-, LOT 1
HILLSIDE NORTH #7;
BLOCK 5, LOT 2
100' WELL RADIUS DOES J
NOT ENCROACH ON THE
PROPOSED SEPTIC SYS1EM
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
PREPARED FOR:
BRIAN MILLER
LEGAL DESCRIPTION:
HILLSIDE NORTH ~7; BLOCK 5, LOT 1
3YPE OF WORK:
SITE PLAN 6
NUMBER OF BEDROOMS: ~-
GALLONS PER DAY (GPD): 600
PERCOLATION RATE/S: 5.2 ~¢ 8.6
=ROPOSED APPUCATION RATE: 0.8
~IINIMUM DRAINFIELD SQ.FT,: 750 FT~
~RAINFIELD DESIGN:
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 2.5 FEET
LENGTH: 55 FEET
EFFECTIVE: 7 FEET
ACTUAL SQ.FT.: 770 FT~
LETTER THAT PERq'NNS TO THIS DESIGN.
TO OBTAIN A COPY Of THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERqY OWNER AGREE THaT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT 7HE TERMS AND
CONDiTIONS OUTUNED.
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPO): 600
PERCOLATION RATE/S: 5.2 MIN/INCH
PROPOSED APPUCATION RATE: 0.8
MINIMUM DRAINFIELD SO. FT.: 750 FI~
SITE DRNNFIELD DESIGN:
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 2,5 FEET
LENCrH: 55 FEET
EFFECTIVE: 7 FEET
ACTUAL SO. FT.: 770 FT=
PROPOSED
ALTERNATE
PROPOSED 100' WELL RADIUS
PROPOSED 1250 GALLON
SEPTIC TANK
PROPOSED
30X60 4
BEDROOM
HOUSE
HOFFMAN, P,I~S. WTH LANTECH
TESTHOLE LOCATIONS WERE
PROFESSIONALLY SURVEYED IN
BY SHANE HOLT, P.L.S.
/
/
'INSTALL FCO DURING
HOME CONSTRUC310N
OCATION OF
10' CUT TO ROAD
DOUBLE CLEANOUTS
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
PREPARED FOR: I PHONE NUMBER: PAGE NUMBER:
BRIAN MILLER 907~)251-5828 2 OF 2
LEGAL DESCRIPTION: DRAWN BY:
HILLSIDE NORTH ~7; BLOCK 5, LOT 1 D.J.G.
3YPe OF WORK: DATE:
~. 40 SCALE SEPTIC SYSTEM DESIGN 6/27/2016
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS~
[SOIL LOG - PERCOI_~TION TESTI
LEGAL DESCRIPTION: HILLSIDE NORTH #7; BLOCK 5, LOT 1
PERFORMED FOR: BRIAN MILLER
DATE: 5/17/16
ORGANICS/LOAM
GW/GN
]TEST HOLE #1 ]
SOIL CLASSIFICATIONS
ORG
ML
CL
OL
MH
CH
OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 5/17/2016
DRY 5/24./2016
SITE PLAN
SCALE:
DATE READING CLOCK NET TINE WATER LEVEL NET DROP
TIME (HINUTES) READING (INCHES)
5/18/16 I 2:22 6"
2 2:52 30 2 1/8" 3 7/8"
3 2:52 6"
4 3:22 30 2 1/2" 3 1/2"
5 3:22 6"
6 3:52 30 2 1/2" 3 1/2"
7 3:52 6"
8 4:22 30 2 1/2" 3 1/2"
PERCOLATION RATE 8.57 (MIN./INCH) PERC. HOLE DIA. (INCHES)
TEST RUN BETWEEN 6 FT. AND 7 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: YES · NO []
SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIKWlDGER
COMMENTS: PERCOLATION READINGS ARE WlTHIN1/16OFINCH.
PERFORMED BY GEG, Ltd, I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PF::~FOF~MED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
ISOIL LOG - PERCOLATION TESTI
LEGAL DESCRIPTION: HILLSIDE NORTH #7; BLOCK 5, LOT 1
PERFORMED FOR: BRIAN MILLER
DATE: 5/17/16
ORGANICS/LOAH
GW/GM
ITEST HOLE #2 I
80IL CLASSIFICATIONS
ORG
ML
CL
OL
NH
CH
OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 5/17/2016
DRY 5/2&/2016
SITE PLAN
DATE READING CLOCK NET TINE WATER LEVEL NET DROP
TINE ' (HINUTES) READING (INCHES)
5/18/16 1 2:20 6"
2 2:50 30 1/4" 5 3/4"
3 2:50 6"
4 3:20 30 1/4" 5 3/4"
5 3:20 6"
6 3:50 30 1/4" 5 3/4"
PERCOLATION RATE 5.2 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES
TEST RUN BETWEEN 6 FT. AND 7 FT.
i A FOUR HOUR PRESOAK WAS PERFORMED: YES · NO []
SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIKWIDGER
CONHENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER~:ORMi~D IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 5/~¢/, ~