Permit Number:
Tax Code Number:
Work Type:
On-Site Water & Wastewater System Permit
OSP161156
O4102175000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: June 28, 2016 to June 28, 2017
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: HILLSIDE NORTH #7
Site LegalAddress: HILLSIDE NORTH #7 BLK 5 LT 1 G:2043
Owner/Address: KREPS KEVIN W & LYNDA L
8580 BROOKRIDGE DR ANCHORAGE AK 995044193
Site Mailing Address:
Lot Size in Sq Ft: 405979
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:~~
Issued
MUNICIPALITY OF
Community Development Department ~,,~ '~//-'~._h_Phone.~.9~2'~3-7904
Development Services ~ ~ 343-7997
On-Site Water & Wastewater Program
Mayor Dan Sullivan
On-Site Sewer/VVell Permit Application
For A Single Family Dwelling
Parcel I.D. 041-02-175
Property owner(s) BRIAN MILLER Day phone 251-5828
Mailing address 7915 PORT ORFORD DR. *ANCHORAGE, AK 99507
Site address NHN MIDDLE ROCK ROAD *ANCHORAGE~ AK
Legaldescription (Sub'd, Block&Lot) HILLSIDE NORTH #7; BLOCK 5, LOT 1
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING:
( [~;~11 that apply) Initial [] Single Family (SF) []
Absorption Field [] (w/wo ADU)
Septic Tank [] Upgrade []
Renewal [] Duplex (D) []
Holding Tank [] Multiple Dwellings []
Privy [] (SF and/or D)
Private Well [~]
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A Distance: -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment: (0 I' h
Receipt Nur ber: C)'5
Permit .o. 0 S P 1 0115 I~
Waiver Fees:
Date of Paymer~:
Receipt Number:
Waiver No.
(Rev. 0~/~)
June 9,2016
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System for Hillside North #7; Block 5, Lot 1
To whom it may concern:
The subject lot is vacant. The property owner is proposing to build a four (4) bedroom
home that will be served by a private well and septic system. We are proposing to install
a new 1250 gallon septic tank and deep trench type drainfield. Two testholes were
excavated on the property and the drainfield is designed around the 30 foot radius of
testhole #2. Comments regarding the design are summarized as follows:
1. SOILS: See the attached 2016 logs which show the soil classifications, groundwater
monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: See the attached 40 scale design drawing which shows
topography. The average topography around the proposed drainfield is 17%. There is a
cutbank towards the west property line, however, the proposed drainfield is >50 feet
away from the cutbank.
We are unaware of any adverse impacts this installation would have on adjacent wells
or septic systems. If you have any questions, please contact us at 337-6179. Thank
you for your assistance.
jeffre/'~/
Presi~'E
I, P.E., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.corn
HILLSIDE NORTH ~7; I~CT C
100' WELL RADIUS DOES
NOT ENCROACH ON THE
PROPOSED SEPTIC SYSTEM
HILLSIDE NORTH ~7; BLOCK 5, LOT 1
1" = 100'
HILLSIDE NORTH #7;
LOT 6
I
\
/
/
NORTH 1~7;
BLOCK ~-, LOT 1
HILLSIDE NORTH #7;
BLOCK 5, LOT 2
100' WELL RADIUS DOES J
NOT ENCROACH ON THE
PROPOSED SEPTIC SYS1EM
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
PREPARED FOR:
BRIAN MILLER
LEGAL DESCRIPTION:
HILLSIDE NORTH ~7; BLOCK 5, LOT 1
3YPE OF WORK:
SITE PLAN 6
NUMBER OF BEDROOMS: ~-
GALLONS PER DAY (GPD): 600
PERCOLATION RATE/S: 5.2 ~¢ 8.6
=ROPOSED APPUCATION RATE: 0.8
~IINIMUM DRAINFIELD SQ.FT,: 750 FT~
~RAINFIELD DESIGN:
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 2.5 FEET
LENGTH: 55 FEET
EFFECTIVE: 7 FEET
ACTUAL SQ.FT.: 770 FT~
LETTER THAT PERq'NNS TO THIS DESIGN.
TO OBTAIN A COPY Of THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERqY OWNER AGREE THaT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT 7HE TERMS AND
CONDiTIONS OUTUNED.
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPO): 600
PERCOLATION RATE/S: 5.2 MIN/INCH
PROPOSED APPUCATION RATE: 0.8
MINIMUM DRAINFIELD SO. FT.: 750 FI~
SITE DRNNFIELD DESIGN:
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 2,5 FEET
LENCrH: 55 FEET
EFFECTIVE: 7 FEET
ACTUAL SO. FT.: 770 FT=
PROPOSED
ALTERNATE
PROPOSED 100' WELL RADIUS
PROPOSED 1250 GALLON
SEPTIC TANK
PROPOSED
30X60 4
BEDROOM
HOUSE
HOFFMAN, P,I~S. WTH LANTECH
TESTHOLE LOCATIONS WERE
PROFESSIONALLY SURVEYED IN
BY SHANE HOLT, P.L.S.
/
/
'INSTALL FCO DURING
HOME CONSTRUC310N
OCATION OF
10' CUT TO ROAD
DOUBLE CLEANOUTS
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
PREPARED FOR: I PHONE NUMBER: PAGE NUMBER:
BRIAN MILLER 907~)251-5828 2 OF 2
LEGAL DESCRIPTION: DRAWN BY:
HILLSIDE NORTH ~7; BLOCK 5, LOT 1 D.J.G.
3YPe OF WORK: DATE:
~. 40 SCALE SEPTIC SYSTEM DESIGN 6/27/2016
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS~
[SOIL LOG - PERCOI_~TION TESTI
LEGAL DESCRIPTION: HILLSIDE NORTH #7; BLOCK 5, LOT 1
PERFORMED FOR: BRIAN MILLER
DATE: 5/17/16
ORGANICS/LOAM
GW/GN
]TEST HOLE #1 ]
SOIL CLASSIFICATIONS
ORG
ML
CL
OL
MH
CH
OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 5/17/2016
DRY 5/24./2016
SITE PLAN
SCALE:
DATE READING CLOCK NET TINE WATER LEVEL NET DROP
TIME (HINUTES) READING (INCHES)
5/18/16 I 2:22 6"
2 2:52 30 2 1/8" 3 7/8"
3 2:52 6"
4 3:22 30 2 1/2" 3 1/2"
5 3:22 6"
6 3:52 30 2 1/2" 3 1/2"
7 3:52 6"
8 4:22 30 2 1/2" 3 1/2"
PERCOLATION RATE 8.57 (MIN./INCH) PERC. HOLE DIA. (INCHES)
TEST RUN BETWEEN 6 FT. AND 7 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: YES · NO []
SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIKWlDGER
COMMENTS: PERCOLATION READINGS ARE WlTHIN1/16OFINCH.
PERFORMED BY GEG, Ltd, I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PF::~FOF~MED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
ISOIL LOG - PERCOLATION TESTI
LEGAL DESCRIPTION: HILLSIDE NORTH #7; BLOCK 5, LOT 1
PERFORMED FOR: BRIAN MILLER
DATE: 5/17/16
ORGANICS/LOAH
GW/GM
ITEST HOLE #2 I
80IL CLASSIFICATIONS
ORG
ML
CL
OL
NH
CH
OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 5/17/2016
DRY 5/2&/2016
SITE PLAN
DATE READING CLOCK NET TINE WATER LEVEL NET DROP
TINE ' (HINUTES) READING (INCHES)
5/18/16 1 2:20 6"
2 2:50 30 1/4" 5 3/4"
3 2:50 6"
4 3:20 30 1/4" 5 3/4"
5 3:20 6"
6 3:50 30 1/4" 5 3/4"
PERCOLATION RATE 5.2 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES
TEST RUN BETWEEN 6 FT. AND 7 FT.
i A FOUR HOUR PRESOAK WAS PERFORMED: YES · NO []
SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIKWIDGER
CONHENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER~:ORMi~D IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 5/~¢/, ~