Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 16TI2N W Lo1' 16 #018-191-04 Permit Number: OSP161203 Tax Code Number: 01819104000 Work Type: Septic Permit Effective Dates: July 21, 2016 On-Site Wastewater DisPosal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade to July21, 2017 Design Engineer: ANDERSON ENGINEERING Subdivision: T12N R3W SEC 33 Site Legal Address: T12N R3W SEC 33 LT 16 G:3034 Owner/Address: YUN HYON N 3298 MORGAN LOOP ANCHORAGE AK 995160000 epartment Site Mailing Address: 2640 DE ARMOUN RD, Anchorage Lot Size in Sq Ft: 16488 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. For the Inspection Report approval, the documentation of the existing field and tank are to have MOA approval. 2. The proposed trench is too deep for the soils information submitted. An additional test hole is to be done prior to construction. Construction may proceed at your own risk before the 7 day water monitoring is complete. Submit results with the Inspection Report. MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Parcel I.D. Property owner(s) Yurt Hyong Nang Mailing address 3298 Morgan Loop Anchorage, AK 99516 ~ Phone:~~ i RUSH! ] 018-191-04 ~*;~^ 3~01-~ Day phone Site address 2640 De Armoun ROad Ar~chorage, AK 99516 ' Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T12N R3W Section 33 Lot 16 Lot Size 16,486 Sq. Ft. Number of Bedrooms Three APPLICATION IS FOR: ([] all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: TYPE OF DWELLING: Initial [] Single Family (SF) [] (w/wo ADU) Upgrade [] Duplex (D) [] Renewal [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_~- :. ',',-.Cc ~' July 19, 2016 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Su~e~: T12N R3W Section 33 Lot 16 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The absorption system on the subject lot is undocumented and undersized and must be upgraded before a COSA can be issued for resale of the property. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the three-bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic systems. The existing septic tank will be exposed and inspected and verified suitable for continued use. It will be replaced if found defective. A portion of the existing absorption trench will be decommissioned in accordance with Municipal Code. Also identified on the plans are the locations of the existing well on this lot and adjacent lots. A waiver to allow the septic tank and absorption trench to be constructed in the planned location has been obtained from ADEC and is attached. No conflicts exist between the proposed septic system and the wells on adjacent lots. Drainage arrows are shown indicating the current drainage patterns. The ground surface in the area of the proposed trench is virtually fiat. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Silty Sand with Gravel (SM) in the absorption zone of the trench. The percolation rate was determined to be between 1 and 5 minutes per inch. No groundwater was encountered during the placement of the test hole and none has developed to date. We have designed the new trench with an application rate of 1.2 gallons per day per square foot. We are proposing to verify the existing 1,000 gallon septic tank and construct an extension to the existing trench 15' TI2N R3W Section 33 Lot 16 July 19, 2016 Page Two long trench by 3' wide with a 6.5' effective depth. The total depth of the system will be 10.5' with the distribution line at 3.5' below the existing surface. The existing absorption trench will be decommissioned 10' from the south property line and the new extension will be constructed parallel to the line. The ground surface on the lot in the area of the new trench is flat. The trench will be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments // / / / 0 Z T12N RSW SECTION 33 LOT 4-0,051 S.F. 16 S 87'49'12" W 79,01' Three Bedroom Home Mobile Home has been Removed from the Property. o garage Z FCO Expose and Inspect Existing Tank. Replace with new 1,000 Gallon Septic Tank if found to be unsuitable for continued use. Abandon and Plug Existing Absorption Trench 10' From the South Property Line. Construct New 15' Absorption Trench Parallel to Property Line. Approximat of Service Line. Line at This Point. Verify Existing sv Septic Tank is Suitable for Continued Use. Extend Existing Absorption Trench 15' to the west. T~ 14' Wl 15' -10' WI S 89'50'24" E 109.93' NOTE: No Conflicts Between the Septic System and the Wells on Neighboring Lots. LEGEND FCO - Foundation Clean Out CO - Clean Out MT - Monitor Tube TH - Test Hole SV - Septic Vent FSV - Flow Splitter Valve T12N R3W SECTION 33 LOT 16 DESIGN FACTORS: Three Bedroom Home Perc. Rate: 1-5 Min./Inch Application Rate: 1.2 GPD/SF 3 Bedrooms * 150 GPD/Bedroom = 450 GPD Total Flow SYSTEM REQUIREMENTS: Deep Trench System 1,000 Gallon Septic Tank 6.5' Drainfield Rock 450 GPDI1.2 GPDISF/13 SF/LF (Width) = 28.8 LF Trench Length THEREFORE: Abandon and Plug Existing Absorption Trench at 10' From South Property Line. Construct a New 15' Long x 3' Wide x 6.5' Effective Depth Absorption Trench Parallel to the South Property Line and Connect to Existing Trench for a Total Length of 29'. Total Depth of Trench to be 10.5' Below Existing Grade. Provide 3' of Cover Over Absorption Trench Flow Line. 6.5 ..,~eotextile Fabric ~ 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION - (NO SCALE) ~~.-~.....~.....~ . ~,~...-?. NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams: CE-12592 4700 1 DEPTH 1 2 3 4 5 6 7 8 9 11 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT E3RAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST BLM LOT 16, TI2N, R3W, SECTION ~,.~ LEGAL DESCRIPTION: PERFORMED FOR: DATE: 5/I/2016 PARCEL ID~:. OB/OG SILTY GRAVEL WITH SAND GM BOH @ 16' JASON MCKEEL PROJECT No.: TECHNICIAN: WAS GROUND WATER ENCOUNTERED? IF YES ~t WHAT DEPTH9 DEPTH OF WATER AFTFA~ MONITORING: NONE DATE OF MONITORING' 5/15/16 [vi. ANDERSON SLOPE No SITE PLAN SEE SITE PLAN DATE READ NG GROSS TIMEINET T'MEI ~%TTHERTO NET DROP I (MI"UTES> I("'NUTES) I ('"0"ES) I('N°HES) TEST HOLE PRESOAKED PRIOR TO TESTING: 15/2I, 2:09 0.38. I 2 2:3930 7.63" 7.25" I 3 2:40 0.50" 4 3:20 30 7.75" 7.25" / 5 3:21 0.50" J 6 3:51 30 7.75" 7.25" PERCOLATION RATE:4.2 .(MIN/1NCH) PERC. HOLE DIA. 6" .(tNCEmS) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/19/16 GOVERNOR BILL X~ALK~It Department of Environmental Conservation Division of Water Wastewatvr Discharge Authorizatim~ Pro.am 555 Cordova Street Anchorage, AK 99501 Main: (907)269-7519 F~x: (907)334-2415 K/Ii~l E. Anderson, ?.~. july 15, 2016 Anderson Engineering P.O. Box 240773 Anchorage, Alaska 99524-0773 Re: South Auchorage-T I2 N, R 3 W, Sec. 33, Lot 16, and Doan Subdivision, Lot [ ~2- Waivers of Separation Distances for a Class C Public Water System-ADEC Plan Tracking NUmber 16 DWW 197 Deer Mr. Anderson, On July 15, 2016 a request for a Class C public water system locaWxl at 2640 DeArmoun Road was submitted for review for waivrs to the wastewater systems that eneroaeh near the source well. You are recoramending these waivers and feel that public health will not be impacted from the existing site conditions. A review of the resent samples and the well log and it's soils information along with the placement of the house between the source well and the wastewater systems of concerns have been evaluated. The following waivers based upon the engineer's recommendation are herein listed. Thc separation distance to the existing septic tank on thc same lot as thc source well is established as 85 feet reduced from thc 150 foot requirement. Caution the septic tank is older and may have reached it's effective live if this unit is in need of replacement it is advised to provide more separation distance than has been provided. The separation distance to the existing soil absorption field on the same lot as the source well is established as 98 feet reduced fi'ora the 150 foot requirement. Caution the older field should it require replacement would again need to be reviewed to assure the concerns related to public health are still in place. The separation'distances to the wastewater system serving the next door property Doan S/D, Lot 1 are an existing 118 feet and ere also reduced from the 150 foot requirement, Should they be fo~md to be in need of replacement or upgrading a farther separation distance needs to be a part of any new development or connection to the Municipal utilities. These waivers are based upon thc engineer's recommendation and the engineering controls established upon the lot which assured the protection of public health. Should it be found that the site conditions endanger public health or are a public health concern, the waiver will be rescinded. This approval does not imply the granting of additional authorizations nor obligate any state, federal or local regulatory body to grant required authorizations. Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18 AAC 15.195- 18 AAC 15.340 or an infmmaal review by the Division Director in accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division Director, 410 Willoughby Avenue, Suite 303, P.O. Box 111 g00, Juneau, Alaska 99801, within 15 days of receiving the decision. Guidance information on the informal review process may be found at http://www.dee.state.ak.us/eommish/Review- Guidanco.htm. Adjudicatory hearings requests must be delivered to the Commissioner of the -Department o~Enviroun~ental ~onservation,-4-}0-Wi-lloughby-Avenue, Suite~303;-, P:.O=. Boxy1 H~800, )uneau, Alaska 99801, within 30 days of the decision. Ifa hearing is not requested within 30 days, file right to appeal is waived. Thank you for your cooperation. If you have. any questions please do not hesitate to contact me at 269- 7519. Respectfully, William R. Rieth, P.E. Environmental Engineer