T12N R3W SEC 33 LT 36B
TI R3W c 33 Lot 36B #018-182-05 Municipality of Anchorage On -Site Water and Wastewater Program ° (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181336 PID Number: 018402-05 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade Name: Craig and Donna Huffman ABSORPTION FIELD ❑ Deep Trench ® Shallow Trench ❑ Bed ❑ Mound Address 3848 E. 142nd Avenue Anchorage, AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade Four (4) 1.0 GPD/SF 4.5-5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4-4.5 Ft. Gravel depth beneath pipe •5 Ft. Subdivision Block Lot 36B Fill added above original grade 0 Ft. Gravel length 120 Ft. Township Range Section 12N 3W 33 Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 Ft 3 > 6 Ft. Well N/A >100' >100' N/A >25' TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity I Gal. Surface Water N/A i >100' >100' N/A Material Number of compartments Lot Line N/A >10' >5' N/A NA Foundation N/A >10' >10' N/A LIFT STATION Manufacturer Anchorage Tank/Orencxo Capacity 500 Gal. Curtain Drain None Noted Remarks Pump on level at 42 in. Pump off level at 38 in. High water alarm at 44 in. Pump make and model Electrical Inspections performed by MOA PIPE MATERIAL House to tank Tank to F81 O drainfield Installer A Plus Drainfield D3034 CO/MT Inspector im BENCH MARK (Assumed elevation) 100 ft Inspectiones: 151 10/24/18 10/25/18 Location and description 2�d 3`d 10/29/18 4"' Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp ®®�� ®0F Conditional Approval: Date �P°.••°`°°°' °•°.°°S,�®p 49th a...,.� ' ..:., . ...°°.ems.. ................................................ a MICHAEL E. ANDERSON No. CE -4381 ®�®TFj�`°°•., 1/31/20 Approved �1� Date Niar pROF ESS 0%P®®® Inspection Report-9-1-12.doc M 0 J co 6 0 U rW�� VJ co ry z N LO I 1 N 00 O W N Z 1 ,t W 0 > V- wa O O F- U) to O C) Q D l'M/ M T- oo M fT- V) �0.yy, W n IN '8nS NOON 'VSE 101 opD G� i= - ------- --------- 7 ------------------- h Z J W W o Q W =_ E- C� wwU Z 0- Q) t= QZ� CO x 2E � p W W O w W p Q) z _ 0-0 CO U W Z >- Cn O Z 2\ 0 (A Q [n \ CO 2i S O �2 elf m zOLL. 2i m 'U o QoLL- LU O W m U 0 Q O p -� -�h m�Q CD ��co CL J Z F - 0U F- ZZ N W 0 (n O Z ow w OO Z Lw z Z F - Z Q o Co F->- Q O W O U- W 0�� P: Q J N Cn O J Z F— O z Q Q ~ m M Whom JJ /� O W 'S --------------------------- ---- �w E— W z aoLL, Q co ~ 3: O W F— F-- 0 O Z O :E LLI(-j�.UW Cl V 0� "30 o Ni =oou>) z t- Y :�E cn U u Q ao v v v M O V WU') C� M cl� (O c0 U� O V (O m O co IT co N LO - o N V U 2 1 2 1 :E . 75; J� Li z z O O z U) SO W W Cl) w m W p U Z F- Z F- O CD �z Q1-- L- U� z z w- Z W > Q O m z O = Op~IU-OU=i- p w0O0wdcn�U W W w W OO O ' OU UF ->=D-= Lli 0 C tL:Eu)E-(L� S H Cn � U w J F- LL N z >-O 0 U U_ O ~ Z w W Z U) p O W S Cl) F- W � Q W n' >- oo LL w F- S � � w LL O O (i O � U) z = O o Ln U_- o It O O of J O (D LO Z � 2! LLI 0 0� S zU)E- } w U Cn [i A O CwU LU U) O CL w O H U) J W 00 Q T12N R3W SECTION 33 LOT 36B PERMIT # OSP181336 EXISTING N 75 1500 GAL SEPTIC TANK 99.5 FINISH GRADE P I D # 018-182-05 > _ c 91.9 1.25" HDPE 500 GAL 86.9 LIFT STATION 86.1 2 95.5 :1�' '- :tior{IrvPiE�r7eu; ,• •:�• :;,:. :.- '^ 95.5 95.0 95.0 MOA APPROVED SAND 93.0 93.0 50' GROUNDWATER @ 90.0 — 9/24/18 Q 88.5 NORTH TRENCH PROFILE AS -BUILT (NO SCALE) 4©�E OF q'U°oo •TT•�.�•4•�•�(9tv�hy((//a�,� °� :MICHAEL E. ANDERSON g� o NO. CE -4381 foo ©pROFESSNC�A ©© T12N R3W SECTION 33 LOT 36B PERMIT # OSP181336 99.7 FINISH GRADE PID # 018-182-05 M 95.5 # ;. ` ; ,,` :.pRriINFaELElRAEK; , t. .:;:. ,'. r , ..' 95.5 95.0 95.0 MOA APPROVED SAND 93.0 93.0 50' GROUNDWATER @ 90.0 - 9/24/18 - 88.5 MIDDLE TRENCH co 100.0 FINISH GRADE o 75 OG H 95.5 DRAINFIELD ROCK 95.5 95.0 95.0 MOA APPROVED SAND f- 93.0 93.0 20' GROUNDWATER @ 90.0 - 9/24/18 Q 88.5 SOUTH TRENCH PROFILE AS -BUILT (NO SCALE) b z I I I I I I 3' ROAD ESMT. BLM LOT 36A PLAT NO. 71-235 S 89059'30"E 299.74' s SEPTIC SYSTEM • SEPTIC SYSTEM PLAT NO. 71-235 BLM LOT CONTAINING 49,502 S.F. ACCESS TO E. 142ND AVE. (2016-028652-0) S 89059'45"E 299.74' REVISED 4/21/2020 NEW SEPTIC SYSTEM PER ANDERSON ENGINEERING, ADDITIONAL IMPROVEMENTS EXIST. AS -BU 121.2' I HEREBY CERTIFY THAT I HAVE SURVEYED THE � I ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO c6 (6 N I 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 M Ie UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR SW3035 1/23/2017 ESTABLISHING BOUNDARY OR FENCE ONES. ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. GRp,VE�- NOTE: NO CORNERS SET THIS DATE 16-02 BLM36B m N I in c) z O .- M m r N I Lo to I Ir U) � I w O o WELL I 1 O O (o ( z O (6 N S 89059'45"E 299.74' REVISED 4/21/2020 NEW SEPTIC SYSTEM PER ANDERSON ENGINEERING, ADDITIONAL IMPROVEMENTS EXIST. AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPS ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR SW3035 1/23/2017 ESTABLISHING BOUNDARY OR FENCE ONES. ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. NOTE: NO CORNERS SET THIS DATE 16-02 BLM36B OF q4 ar co 49TH •;10 ... �-ff-" ............ 10 .10 .... m :A. Gastaldi : o a LS -6091 i yam+AV % 4/21 /2020 •e° �J �P • ••. yo d ••as•• Pa 'ot"Ossiona\ �o UIL I O DETAIL SCALE: 1 "=20' MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP181336 Work Type: Septic Upgrade Tax Code Number: 01818205000 Site Legal Address: TI 2N R3W SEC 33 LT 36B G:3035 Site Mailing Address: 3848 E 142ND AVE, Anchorage Owner: HUFFMAN CRAIG D & DONNA L Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: r1617 --f Deparnucnt 9/25/2018 9/25/2019 49502 Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: l ,� ` Date: -I l �i Issued By: fizeeC.r, (a Vt� Date: 4 MUNICIPALITY OF ANCHORAGE . Community Development Department o Phone: 90 . -•a4 Development Services Division Fa. ,1Y - a - 47' On-Site Water & Wastewater Program SW �o ON-SITE SEWER/WELL PERMIT APPLICATION c _ ti Parcel I.D. 018-182-05 < artC' Property owner(s) Craig and Donna Huffman Day phone °l 6 Mailing address 3848 E. 142nd Avenue Anchorage, AK 99516 Site address Same Legal description (Sub'd., Block & Lot) Lot 36B Legal description (Township, Range & Section) T12N R3W Section 33 Lot Size 49,502 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field ❑X Initial Single Family (SF) X (w/wo ADU) Septic Tank ❑ Upgrade Duplex (D) U Holding Tank ❑ Renewal I Multiple Dwellings Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. e (Signature of property owner or authorized agent) Permit/Rush Fees: //��51/ Waiver Fees: Date of Payment: `t 1/90 Date of Payment: Receipt Number: (267402 Receipt Number: Permit No. DSP/X33(0 Waiver No. Permit App_ • ::.,c I. GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) September 18, 2018 MOA Development Services Dept, On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: T12N R3W Section 33 Lot 36B—3848 E. 142" Avenue Septic System Design and Permit Application Dear On-Site Services Engineer: The septic system on the subject lot has failed and must be replaced. We are submitting this design and permit application for the construction of a new septic system to serve the house on the lot. The attached site plan identifies the location of the home and the existing well and the existing well and septic system. No conflicts exist between this proposed system and any other well or septic system,whether on this lot or adjacent lots. The ground surface on the lot is virtually flat in the area of the proposed absorption trenches. Storm water drainage will not impact this septic system. The new trenchess will be constructed parallel to the slope as much as possible. The new septic system will be a minimum of 100' from all wells and surface water, and more than 5' from the septic tank. The existing absorption trench on the lot will be abandoned in place and all aboveground pipes will be removed. Please refer to the attached test hole log, laboratory gradation and plan and profile sheets for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, n n �P��pF A(gst990i *: 49 . Michael E. Anderson,PE 114, -'1 E d Attachments �+ %Mic 94 E. AEderso� � • t,>>�PROFa 4";; LLi 11.9nS NOOA'VgC iOl 0 U) 0 Lli Uj CO w W r) < GRAv W 0 (D 0 <z WWLIJ �- -j W < > -j < _j o 0 -j 0 C) 0 -, w M:z 0 < -- 7- ----------------- CO CO C:l W 0 0 0 LU r) LL LU LIJ W LU (LD IJ 6 ( o) 8) FL i CIII LL. � cl) z ui LLJ U) w o z D < ui F- Cl) " z WF-- LLJ 3: a 3: 2 C) me P k C3 Lu Uj U w ui z r -K C) L-jL- F- < Cl) z U)< > zo U) 0w 0 C) UJ z LLJ 0- C) W\ (D co azo 0 LU 7; C) C/) < c) U- Lo -i < ILI 0 0- W7- LU Z w Co 0 0 ui < WW W Of ED ui 2i 0 d CD 0 2i � ui 2: 0 — 0 < c) b wCO W — a_ LL- < 0 LL 0 C) 0 Cf) Lu ::D o 0 U) LU 0 z ,-jCD < LO 0 U, 75; 03 F-- 0- Z r- ui C) 0 CD m W ry 0 :D < 0- z z (-) z ui C) 0a < �: z w (D :> M W w U) U) W:5 Z W Uj LLJ LLI -r z cc W ;z w w F-- U) :�; t- C) F- 0 < -r U) CL Lu �- IU) U) >- UJ U) A- LO 0 — z < Co z w 0- T< < Z 0 w w 0 (f) CD w 0 p w ::D Fes -- m 0- w 0 Q CO 0 w Z Q Z > 0 r'j 0 < 0 Z Q- < U) 0 W w C� 0 rK w > ry < o Q_ < ry 0 (D w m (n , z uj ry < co 0 C) Iwo co LO 25 :5 U) Lu 0 < co co 0 co z Z ui --J < ZD I-- 0 LIJ 0 U) 5: = CE Lw ---------- �— UJ - >- Z �r) ry w U) 0 '0 z z ry _j X0 LU w to b < <1m~ f) LO '00 < w co C"i z a - A UJ 3: 0 LJ U) �- U) o U) 0 z 0 LIJ r1l oj 0 UJ a_ -j --j 0 U) < LIJ CIMJ �"3(]NnHi 0Z) 0 o cin 0 J) j ��: z LLJ U) _j 0 0= < -1 T12N R3W SECTION 33 LOT 36B DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW S WIDE TRENCH SYSTEM PERK RATE: <1 MIN/IN EXISTING 1,250 -GAL SEPTIC TANK APPLICATION RATE: 1.0 GPD/SF 500 GALLON LIFT STATION 600 GPD / 1.0 GPD/SF /5' WIDE* 1.0 RED. FACTOR = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) BOTTOM OF TRENCH: 4.5' BELOW GRADE FLOW LINE ELEVATION: 4' BELOW GRADE TOP OF TRENCH:.5' ABOVE GRADE a 3.5'1= I I �I TIMI �I�. ISI I I I �T�I 6" 6" 1.25" PERFORATED PVC (HOLES DOWN) 16" DIAMETER HOLES 2' 30 TOTAL @ 4' SPACING DRAINFIELD ROCK IkU•7_t_TJJZ•]TIIZ.�_�r•��� A� D �► o NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 ELMORE ROAD ANCHORAGE, /-\,K 99519-6650 SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: T12N R5W SECTION 35 LOT 56B PERFORMED FOR: A PLUS HOME SERVICES DATE: 1012Z,118 PROJECT No.: PARCELID#: 018-182-05 TECHNICIAN: J. MILLETTE DEPTH FERC. TEST I (feet) 7 8 9 10 11 12 13 14 15 16 17 18 19 20 WAS GROUND WATER ENCOUNTERED? NO m S1 E FLAN SEE SITE PLAN IF YES @) WHAT DEPTH? SL GROSS TIME (MINUTES) DEPTH OF WATER AFTER MONITORING: 0 1' OB DATE OF MONITORING: r 1 2 6/12 6 2 3 6/12 SILTY GRAVEL FILL 3 4 6/12 6 POORLY GRADED GRAVEL 5 GP 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 WAS GROUND WATER ENCOUNTERED? NO m S1 E FLAN SEE SITE PLAN IF YES @) WHAT DEPTH? SL GROSS TIME (MINUTES) DEPTH OF WATER AFTER MONITORING: 0 NET DROP (INCHES) DATE OF MONITORING: r 1 DATE READING - GROSS TIME (MINUTES) NET TIME (MINUTES) WATER DEPTH TO (INCHES) NET DROP (INCHES) 10/24 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 <3 6/12 6 2 <3 6/12 6 3 <3 6/12 6 PERCOLATION RATE: <1 (MINANCH) PERC. HOLE DIA. §—(INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST COMPLETED IN ABSORPTION TRENCH UNDER M.O.A. SUPERVISION. 44'. MUNICIPALITY OF ANCHORAGE •.�P ... �r q,•..;+ •♦ DEVELOPMENT SERVICES DEPARTMENT fid• 4��"••. 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 N r.rA'• 49th p �� •° �� SOILS LOG AND PERCOLATION TEST -o ;MICHAEL E ANDERSON: • i�•t NO. CE-438t •.4._'= .S�TF, . .ctC'd LEGAL DESCRIPTION: T12 N R3W SECT I ON 33 LOT 36B # 0.,pROfESS,�P:4• 4 PERFORMED FOR: A PLUS HOME SERVICES ,'1Itwas" DATE: 9/13/18 PROJECT No.: Professional Engineers Stamp: PARCEL ID#: 018-182-05 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE A (feet) 1' OB SLOPE SITE PLAN 3 .'., }. x:2. .7 SILTY GRAVEL FILL 4 —I?'. •... 5 •:J :�' ';! SEE SITE PLAN k ;:,..1 .;,..,•.7.:;-;- 6 -:•::1•':44.4.:,!',.!t. •� ,,fN: 7 ;' ;_' POORLY GRADED SAND SP 8 .V-..:!.•i- -.-‘'i 10 . +': WAS GROUND WATER ENCOUNTERED? YES r'!:.::. ;::..:?;.;:::: IF YES,a,WHAT DEPTH? 9.5' S 1 1 y.:•,.•' ••.< DEPTH OF WATER AFTER MONITORING: 9.5' DATE OF MONITORING: 9-24-18 12 GROSS TIME NET TIME DEPTH To NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 9/13 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 3:00/3:03 <3 6/12 6 16 2 3:04/3:07 <3 6/12 6 • 3 3:08/3:11 <3 6/12 6 17 4 3:12/3:15 <3 6/12 6 18 5 3:16/3:19 <3 6/12 6 19 6 3:20/3:23 <3 6/12 6 20 PERCOLATION RATE: <1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 5 FT. and 6 FT. COMMENTS: • r NORTHERN GEOTECHNICAL ENGINEERING, INC./ TERRA FIRMA TESTING Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis PROJECT CLIENT: Forge Engineering %GRAVEL 34.9 USCS SP PROJECT NAME: 3848 E.142nd Ave %SAND 61.0 USACOE FC N/A PROJECT NO.: 4914-18 %SILT/CLAY 4.1 %PASS.0.02 mm N/A SAMPLE LOC.: %MOIST.CONTENT 3.9 %PASS.0.002 mm N/A NUMBER/DEPTH: UNIFORMITY COEFFICIENT(Cu) 22.5 DESCRIPTION: Poorly-graded sand w/gravel COEFFICIENT OF GRADATION(Ce) 0.4 DATE RECEIVED: 9/17/2018 ASTM D1557(uncorrected) N/A TESTED BY: CH ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422/C136 uS.WYE OPENING 117!HMS I US.SIEVE1111A01ERS 1 11YMI0.UF.rFR SIEVE ANALYSIS RESULT lI 3f11 - II .�0 10 N 10 .So.140 #2po 100 1 I I SIEVE SIEVE TOTAL% SPECIFICATION 90 SIZE(mm) SIZE(U.S.) PASSING (%PASSING) ♦ I 80 4 152.40 6" 70 —.__.. 76.20 3" ♦ - 38.10 1.5" 100 cn 60 - 19.00 3/4" 98 50 • 12.70 1/2" 87 9.50 3/8" 80 � 40 .--- • ( ------ 4.75 #4 65 -- "-- -`- 2.00 #10 52 30 • f 0.85 #20 41 20 . it - 0.43 #40 27 -- -- - 0.25 #60 17 10 - • 0.15 #100 9 ---- -- ♦ I --i 0 --....... 0.075 #200 4.1 100 10 1 0.1 0.01 0.001 GRAIN SILL(mm) HYDROMETER RESULT I I GRAVEL SAND ELAPSED DIAMETER IO'fALV. PASSING COBBLES SILT or CLAY TIME(MIN) (mm) Comae Fine Coarse Medium Pine 0.5 I MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 8 -- - — — 15 140 -- - — 30 - -- --. — 60 3135 ----'— 250 >-, —1 - L-. 1440 7 130 — Q • 1 . HYDRAULIC COND. 125 —� (ASTM D2434) NIA e4 . ; _- ...._-..._ (ATM T-313) N/A 120 ._----- -- I- -- -- PLASTICITY INDEX N/A 115 1 i — — -— . ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGE-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 - Phone:907-344-5934 • Fax:907-344-5993 • svwiI'.nge-lft.conl Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP161214 018182O5OOO WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343~7904 Initial Permit Effective Dates: August 01, 2016 to August 01, 2017 Design Engineer: ANDERSON ENGINEERING Subdivision: T12N R3W SEC 33 Site LegalAddress: T12N R3W SEC 33 LT 36B G:3035 Owner/Address: CROWN POINTE INC PO Box 112313 ANCHORAGE AK 99511 Site Mailing Address: 3840 E 142ND AVE, TRLR, Anchorage Lot Size in Sq Ft: 49502 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Araska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. s Special Provisions: 7 day ground water monitoring is to be done pdor to construction. Submit ults with the Inspection Report. Received By: Issued By: MUNICIPALITY OF ANCHORAGE Community Development Department ~,//m ~. Phone: 907-343-7904 USH! Development Services Division , j Fax: 907~7 On-Site Water & Wastewater Program k J ON-SITE SEWER/WELL PERMIT APPLICATION /'7(~-( JUL ~ .~ 2016 Parcel I.D. 018-182-05____ Property owner(s) Crown Pointe Inc. Day phone 2~ 9~1,~86 Mailing address P.O. Box 112313 Anchorage, AK 99511 Site address 3848 E. 142nd Avenue Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T12N R3W SEC 33 Lot 36B Lot Size 49,502 Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: __ Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_2- :, ~'.-.Cc ~' ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 27, 2016 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~e~: Lot 36B T12N R3W Section 33 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 36 intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Ground surface contours and drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not change as a result of this project. The test hole placed on the lot in the area of the absorption trench and alternate site indicated organic material to 1' underlain by well graded gravel (GW) with minor amounts of silt. The percolation rate of the soil was determined to be 4 minutes per inch. No groundwater was found during the placement of the subdivision test hole and none developed during the monitoring period. Ap application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and a $0' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 5' below the surface and the total depth will be 9'. To prevent frost penetration 4' of fill must be placed over the septic tank and 3' over the absorption trench. In lieu of fill 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the west at shallow grades. The new trench will be constructed parallel with the contours of the Lot 36B T12N R3W Section 33 July 27, 2016 Page Two shallow grades. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments E. 142ND AVENUE .OT 37B :)T 36A BLk~ LOT 35B BLM LOT 60 '" BLM BLM LOT 36B T12N RSW SECTION AREA IvlAp SCALE 1' = 100' 55 Z // I I / I I I I I I I I I I I I I I I // iI iI iI THUNDER ROAD '"""'-,.., o N O0'07'O0"W 165,16' x · oo9.m. =_x. 1 O' UTILITY ESMT. N O0'07'O0"W 165.14' LOT 36B T12N R3W SECTION 33 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 4 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 SF/LF*.5 (Red. Factor) = 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 5' Below Original Ground Surface. Total Depth to be 9' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Natural Backfill Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION NOTE: Grade Area Over Trench to Drain Away. ~/ Minimum 6' Separation From Bedrock. ~.~.~'.,...~.T.,,~.,~.,..~ Minimum 4' Separation From Groundwater. ~ ~'~ Minimum 100' Se aration From Wells in the Area ~'~ U~*~LE *~'"'"""""'"""";';~SO'~'"'~ Minimum 100' Separation From Sufiace Water or Streams. ~% No. CE~ 4700 DEPTH (feet) 1 2 3 4-- 5 6 7 8 9 11 20- MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST ] LEGAL DESCRIPTION: BLH LOT 06B PERFORMED FOR: DATE: 7/27/16 PARCEL ID#: CROWN POINTE. INC. PROJECT No.: TECHNICIAN: I TEST HOLE1 I 0G WELL GRADED GRAVEL WITH SOHE SILT GW WAS GROUND WATER ENCOUNTEKED? __ IF YES ~ WHAT DEPTI42__ DEPTH OF WATER AFTER MONITORING: DATE OF MONITORING: BOH @ 16' W. ROBERTS SLOPE NO 0 Professional EA¢~ Stamp: SITE PLAN SEE SITE PLAN DATE READING GR. OSS TIH. E .NET TIM.E %.~.~RTO N,ET DRQF I tHINUTES; It"'"UTES) I ('NCHES) IuNcHEs; TEST HOLE PRESOAKED PRIOR TO TESTING: 7/26 1 10:19 1.13" 2 10:49 30 8.63" 7.50" 3 10:50 1.00" 4 11:20 30 8.50" 7.38" 5 11:21 1.25" 6 11:51 30 8.75" 7.38 PERCOLATION RATE: 4.0 .CMiNf!NCH) PERC. HOLE DIA. 6" .(INCHES) TEST RUN BETWEEN:. 5.0 FT. and 6.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THiS DATE: 7/27/20[6