ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP161132 PID Number: 015-282-56
Dwelling:* Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑■ New ❑ Upgrade
Name:
Spinell Homes, Inc.
ABSORPTION FIELD
EJ Deep Trench •Q hallow Trench [M Bed E] Mound
Address
1900 W. Northern Lights, Anchorage, AK 99517
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
344-5678
Four
.5 GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+.5 Ft.
Gravel depth beneath pipe
•5 Ft.
Subdivision Block Lot
Woodhaven No. 3 11
Fill added above original grade
4.8-5 Ft.
Gravel length
40 Ft.
Township Range Section
Gravel width
30 Ft.
Beds: Number of Lines
5
Distance between lines
6 Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
1,200 Fe
Ft.
Well
>100'
>100'
>100'
>75'
>25'
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding X Other
Manufacturer
Advantex/Anchorage Tank
Capacity
1 1,500 Gal.
Surface Water
>1
>100'
NA
NA
Material
Fiberglass/FAP
Number of compartments
Two
Lot Line
>5'
>10'
NA
NA
NA
Foundation
>5'
>10'
NA
NA
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
None
Noted
Remarks Final Grading to be Completed by
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
June 15, 2017.
Pump make and model
Electrical Inspections performed by
MOA
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
Installer
Pomranning Excavation
Drainfield F810 CO/Mr
Inspector MEA
BENCHMARK (Assumed elevation) 100.0 ft
Inspeecttiones: 15` 12/12/16 12/13/16
Location and description
2^d
3rd 12/15/16 41h
Finished Floor.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
`rn�'
OF
�1
Conditional Approval: � (!�, l�� r� �;-L t �^ Date
° oS
49 TIA
1"C.J 6V1 6/I 5 I-7
�oee ceor.oeee•o,/o° `�ee e'' o
oeeoeso.aeeoese.. .o.. .............
hNCHAEL E. ANDERSON: e
Ct-4381
Approved"'--, I v� � � Date � J~!
��� "OROfESS\O' G" �d
Inspection Report_9-1-12.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
MEMORANDUM
DATE: April 18, 2017
TO: Tim Ecklund
FROM: Mike Anderson, P.E.
SUBJECT: Lot 11, Woodhaven Subdivision No. 3
Certificate of On Site System Approval
The absorption bed for Lot 11 , Woodhaven Subdivision No. 3 will require substantial
grading before it is acceptable. The surface conditions on the site are not suitable to
complete the grading at this time. We are therefore requesting a Conditional COSA be
issued so the property can be transferred. The grading will be completed no later than
June 15, 2017. The grading will have no impact on the operation of the septic system.
The surface of the lot is basically flat in the area of the new absorption bed. The
configuration of the bed is rotated 90 degrees from the design to allow additional
grading and landscaping area in the back yard. Placement of the bed in this
configuration does not impact wells or septic systems planned for the subdivision.
Municipality of Anchorage Permit Number: OSP161132
DEVEOPMENT SERVICES DEPARTMENT
PID No.: 015-282-56 4700 Elmore Road Anchorage, AK. 99519-6655-343-7904 Page 2 of 3
A B / N 8 28 25?"E
MH1 23.9'20.6' G\�
MH2 28.5'28.1' \�
C4 63.0'29.5' G�� Ng"QO6 •r _�
M1 64.2'52.6' ��/ 0-, .
C5
-
C6 70.2'39.1' l(�� / /// `1 r
� / WELL 1 0
C773.7' 43.6' /� U� / /
4/
v P`�P / / N
C8 77.7' 48.6' 't 1 / 'A/ 1 tg
M2 61.6' 29.2' / tiO /// r o
/ 711-
:3
// / 11N�r" 11I 111rn to/ \ 1j10 LA-
/
I o I I. ; 11
o 11
o I 4.--
1
`. / /
it 4 / l
4,./`' 1 ,�4,./`' / / ®2 Four Bedroom \rn
/ �, ,, / / Home
/ �-
cb' 0 / / a
'S' �v / /
•
u .6.j / / c0
/ / 0 N
/ / FCO Q
//// / AIHI , N
1/ / f� m 0,
< FAH2 w
/ \ 2C0 W
S \ Alternate 1 LJ N
A \ Site u2'/C4 TH22 d'
�A9, \\ THA ---.. __.__._ _..�C5® 0
\ ~ 4C6 O
Cn \ *Si CCB — 7
9& \
6Z9' \ J
10' T. & E. ESMT.
•
S 89'59'13"E 151.83'
al'c-,.... ,:"••v'•, WOODHAVEN SUBDIVISION,
a ' 49th " ` '� % AD D N . NO. 3, LOT 1 1 LEGEND
% �*r • 40,704 S.F. MT Monitor Tube
ToOkBENJAMIN J. SCHILLE •� FCO — Foundation Clean Out
r- PLAN AS BUILT TH — Test Hole
�.�(›:,. No. -CE-12592 '•) CO - Clean Out
♦�#i,�.�~/ �Q.4.„ �~� SCALE 1' = 40' 2 0 -SD ubleVent
Clean Out
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655-343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit No.: OSP161032 PID No. 015-282-56
0
U
N
97.8— - -
U cn 2
_Finished Grade
Existing Grade
94.1-1
21,500
Gallon
Advantex Tank
93.8
1\:'f\e1
N
98.0 98.0
Finished Grade
Geotextile Fabric
Original � lJ Original
Ground 93.7-2 Drain Field Rock 93.7 Ground
93.2 / MOA Approved Sand 93.2—/
92.0
40'Bed Length
Groundwater @ 89.2'
10-15-13
82.2 �-
PROFILE AS - 3UILT
Scale: NONE '
49t I\ * t0.
r
MICHAEL E. ANDERSON
4,+417OFESSITnie,
MUNICIPALITY OF ANCHORAGE .voe.iir►rtitkii,,
DEVELOPMENT SERVICES DEPARTMENT .mss*\-- YF "a/�♦.
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 �,•����� .,„1,- •0
i 49th 1� •
I.
SOILS LOG - PERCOLATION TEST Js4JLL ,
00.MICHAEL E. ANDERSON•:G,_
WOODHAVEN SUBDIVISION No. 3, LOT I I �. '•. No. CE-438ti�
LEGAL DESCRIPTION:
.;*"44-.1.6.71' .2..... 4°
PERFORMED FOR: SPINELL HOMES 44 P ;; .
DATE: 1/2 2/13 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. H A RA L A Professional Engineers Stamp:
DEPTH TEST HOLE No. 22
(feet)
SLOPE SITE PLAN
0
OB/OG
•j �
"i•„` SILTY SAND
4 — WITH VARYING SILT SEE SITE PLAN
5
6 ..• • SM
•
7 >.•”
8
WAS GROUND WATER ENCOUNTERED? YES
9 .•`..:.<'" IF YES @ WHAT DEPTH', 9
• DEPTH TO WATER AFTER MONITORING: 3.
1 0 .1"!< .• DATE OF MONITORING: 5/15/13
:::4:<:''.. :
,.: 5/15/14 3.
11 v BOH @ II'
GROSS TIME NET TIME DEPTH TO NET DROP
12 DATE READING (MINUTES) (MINUTES) WATER (INCHES)
(INCHES)
13 1/25 TEST HOLE PRESOAKED PRIOR TO TESTING:
14 1:18 2.50"
2 1:48 30 2.88" .38"
15
3 1:49 2.50"
16 4 2:19 30 2.82" .32"
17 5 2:20 2.50"
1 S 6 2:50 30 2.82" .32"
19
PERCOLATION RATE: 94 (MIN/INCH) PERC.HOLE DIA. 61t (INCHES)
TEST RUN BETWEEN: 2 FT. and 3 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I,MICHAEL E.ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 4/18/17
Certified Drilling Log
DOC CO dba
BILL 8. COLE
11► ULLIVAN WATER WELLS
'0P.O. Box 670269, Chugiak,AK 99567 688-2759
OWNER OF LAND: Spinel) Homes Bore Hole Data
ADDRESS: 1900 W Nrthn Lights Blvd #200 A/A 99517 Depth
LEGAL DESCRIPTION Woodhaven #2 TR D-1B-A From To
DATE: 10-27-16 0 2 Casing Stickup
PERMIT NUMBER: OSP161132 DATE OF ISSUE: 8-5-16
TAX IDENTIFICATION NUMBER 01528187000 2 4 Overburden
Is well located at approved permit location: Eyes No 4 22 Silty Sand &Gravel
Method of Drilling: ®air rotary ❑cable tool 22 24 Silty Sand &Gravel Wet
Depth of Well: 121' 24 72 Silty Sand & Gravel w/Clay
Casing Type: Steel Wall thickness _250 inches 72 79 Tight Sand & Gravel 3 GPM
Diameter: 6 inches, depth 120 feet
Liner type 79 115 Silty Sand & Gravel w/Clay
Static Water Level: 65 feet 115 121 Sand & Gravel Water
Recovery Rate 15 gpm ❑ gph
Method of Testing
Well Intake Opening Type: ®open end ❑open hole
❑ Screened Start feet Stopped
❑ Perforations Start feet Stopped
Grout Type: Bentonite Volume: 50 lbs
Depth:from 2 feet,to 42 feet
Well Disinfected Upon Completion: Eyes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments:
WATER QUt ("Y TESTING
Cd CoU100mL
Nitrates 2 . 3 5` mall.
Arsenic t1l D ualL
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
MatSu Borough: Department of Environmental Conservation.
DOC CO dba
IP
00111* ULLI8.VAN WATER WELLS
OP.O. Box 670269, Chugiak,AK 99567 688-2759
www.sullivanwaterwells.com
Pump Installation Log
Well Drilling Permit Number:SW OSP161132 Date of Issue 8-5-16
Parcel Identification Number: 01528187000
Legal Descrpio,n Property Owner Name &Address
Woodhaven Lot 11 Spinel) Homes 1900 W. Northern Lights Blvd#200
Anchorage,AK 99517
Pump Installation Date: 1-31-17
Pump Intake Depth Below Top of Well Casing: 110 feet
Pump manufacturer's Name: F&W
Pump Model: 4F07P053015
Pump Size: 1/2 hp
Pitless Adapter Burial Depth: 10 feet
Pitless Adapter Installer: Pomraning Excavation
Disinfected Upon Completion? ® yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments: Pitless Manufacturer: Martinson
Pump Installers Name: Sullivan Water Wells
Attention:The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Q
Municipality of Anchorage
Development Services Department
P.O. Box 196650-4700 Elmore Road
Anchorage,Alaska 99519-6650
Info and Help: (907)343-8211
INSPECTIONS:
Voice:(907)343-8300 Fax: (907)249-7777
4/17/2017 Inspection Report
License/AP#: E14-1295
Parent AP#: R14-1223
Inspection #: 450179
Type: RES
Status: Issued
Address:
Parcel: 01528187000
Inspector: M.Green
Project:
Resp Party:
Descr: 2571 Sq Ft Living and 714 Sq Ft Garage
-BWP
Inspection ElecFin (Final Electrical)
Item:
Evaluation: Approved
Result Notes: Electrical final approved.
Inspection Item Item Description Evaluation
PLAT NO. 2016-76
WOODHAVEN SUBDIVISION , ADDN . NO. 3
LOT 1 1
40,704 S.F.
� N 82°05'22'1E
28,25
� %
4<>',/ 400 l _ T
O• ti� — \ f
, - \
4 / / M 1 Z .
N6 / / o \ S.
! / A \ O -.
I i \ r' r,
1 � \ S w
I , 0
Ii
/ t
•
1
/ ' ! / ��i'/S'>> 45.9' \t`'
ilo
'`a L'' / !
v h / io
• 70.6' 1 " =40'
/ / a I
. �
�. I w w
Sri,. \ SEPTIC SYSTEM •• I . ?
`fS?. \ •
I
�6 a 8
r z
s�
ti
ss \
1
\ 10' T. & E. ESMT,
•
S 89°59'13"E 151.83'
4.0.
6
,Q
6
.0% cofr a
6
/ 80
. ?J%y r?i'
O 4
4, l'.O•
/
BUILDING DETAIL
73:0, SCALE 1"=20'
4 4
As-/00 h kp
AY
fB
•O•
4
'V BS.O
(V. f3
�S.
/� p REVISED 4/13/2017 ADDED MISSING SEPTIC VENTS.
H S --B U I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO �t�,
GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. *s ori,
SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO �.,V� .OF•• ,q� I,
JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, tib';:'• ��•'•;�`' •
2000 E. DOWUNG RD., SURE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT i �. 491 *i
ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT, •
PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA • r
GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR • . Jeffery A. Goatoldi ; o all
ESTABLISHING BOUNDARY OR FENCE ONES. ♦% % 41/1/1.-./...alb •
SW2735 12/28/2016 DISTRICT, ALASKAw1 °a•.. . • 5�.#
ANCHORAGE RECORDING STRIC , .� Prof, 6�
F.B. JOB NO, NOTE : NO CORNERS SET THIS DATE +Illttls'
16-02 WHS11
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY OF ANCHORAGE
AND p,„.,04 tc4 �InhSark
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
5 Day of fkpr i 1 of 2011 ,by and between v�v�Sor� ,
herein the"OWNER,"and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein,the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as
located at (legal description).
L.0 R oOek VC v.
2. Definitions.
Alteration. Any change to the design or function of an AWWTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On-Site Systems Approval(COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included
in the original design which would allow the AWWTS to continue to
perform as designed.
Permit. An On-Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AWWTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AWWTS is in use or is operational or until the
property is sold or title is transferred by the owner and a new COSA is issued to the
new owner or transferee of the property.
4. Alterations, Installation and Removal of Additional Equipment. Prior to
performing any alterations to an AWWTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AWWTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AWWTS
service and maintenance provider approved by the municipality and the
manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it
shall be the responsibility of the Owner during the term of this Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay
for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and(5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules
and orders for the AWWTS.
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to this
information.
D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On-Site Systems Approval.
H. Owner agrees that the AWWTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AWWTS.
6. Nonwaiver. The failure of either party at any time to enforce a provision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to enforce each and
every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended,modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
a. Owner: at-t f -i- -Tr-e, i bhV�Sfl�'
b. Municipality: Director. Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
9. Severability. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
OWNER:
By: (signature) Date: 21-5'/ 7
Vortua4 (print name)
STATE OF ALASKA )
) ss.
THIRD JUDICIAL DISTRICT )
The foregoing instrument was acknowledged before me this S day of Ay( 1
201-k-, byt2G�6\1 -56hr‘(-NoY.
011110.
4.• SSI 04r. i
oF-F,o.
•
NOTAR PU O
IC FOR ALASKA y `TY
.— m:
My Commission expires: CZ C1 � . �ust�o • •
•
• Ncil .•
•
1?-1:$;2°•..41•%
Area re OF PL ,••
•81111 '
MUNICIPALIT .—
y: wv- (signature) Date:
(print name) Title:
Permit Number:
Tax Code Number:
Work Type:
On-Site Water & WasteWater System Permit
OSP161132
01528187000
WelISeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: August 05, 2016 to August 05, 2017
Design Engineer: ANDERSON ENGINEERING
Subdivision: WOODHAVEN #2
~Site LegalAddress: WOODHAVEN #2 TR D-1B-A G:2735
Owner/Address: SPINELL HOMES INC
1900 W NORTHERN LTS BLVD #200 ANCHORAGE AK 995173342
Site Mailing Address: 11740 ELMORE RD, Anchorage
Lot Size in Sq Ft: 861890
Total Bedrooms: 4
epartment
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
I S
pecial Provisions: At least 2 new perk tests are required prior to construction in order to have
both fields within 30' of a perk test.
Received By:
Issued By:
Date: S15/I
May 25, 2016
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Tract D-lB-A, Woodhaven Subdivision No. 2
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
Tract D-1B-A of Woodhaven Subdivision No. 2 is currently being subdivided into 13
lots. The owner of the tract intends to construct a four bedroom home on what will
eventually be Lot 11. The tract is currently undeveloped so we are requesting a permit
be issued for the construction of a new well and septic system for the entire tract to
accommodate the home. The attached Site Plan and backup documentation identify
the location and configuration of the proposed well and septic system along with the
alternate site. No existing wells or septic systems are within 200' of the proposed
systems nor are wells or septic systems proposed for the adjacent lots that will conflict.
Drainage contours are shown on the site plan showing the grade and direction of flow
on the lot. The drainage pattern will not be changed as a result of this project.
A test hole was recently placed on the lot in the area of the absorption bed. It indicated
the presence of silty gravel with some sand (SM/ML). The percolation rate of the
material was determined to be 120 minutes per inch. The characteristics of the
underlying soil was found to be similar to the test hole placed dudng the eadier phase
of the subdivision project and identified as TH12 on the Site Plan. Groundwater was
found during the placement of that test hole at 10' and rose to 4' during the monitoring
period which included October 13, 2013. This again was similar to groundwater
measurements in the new THA. An application rate of .5 gallons per day per square
foot was used in the design of the absorption system. An Advantex Treatment System
designed for a four bedroom home will be placed on the lot along with a pump vault.
Effluent will be discharged into a 40' long by 30' wide absorption bed. The distribution
line in the bed will be placed at .5' above the surface. Existing organic matedal will be
removed to 1' below the surface and replaced with coarse sand to the existing ground
surface where drainfield rock will be placed. A minimum of 2" of insulation and 2' of fill
will be placed over the absorption bed and 4' over the septic tank.
Tract D-lB-A, Woodhaven Subdivision No. 2
May 25, 2016
Page Two
The ground surface on the lot in the area of the absorption bed slopes at a shallow
grade to the west. The new bed will be constructed parallel with the slope as much as
possible in conformance with Municipal requirements. The new septic system will be
constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
/ \
-~ !
',,4/
/
/
z
// ¢4:)
N O0'O0'IO"E 4-78.16'
0
3> 0
C~ C~
/
/
o
o CO_I
N 00' 12'03"W
F
// ///
F
Z
TRACT D-lB-A, WOODHAVEN SUBDIVISION NO. 2
(PROPOSED LOT 11 WOODHAVEN SUBDIVISION NO. 3)
DESIGN FACTORS:
4 Bedroom Home
Perc. Rate: 60-120 MinJInch
Application Rate: .5 GPD/SF
SYSTEM REQUIREMENTS:
Shallow Bed System
1,500 Gallon Advantex Treatment Tank
1' Total Depth Drainfield Rock
Pump Vault
4 Bedrooms X150 SF/Bedroom/.5 GPD/SF(Application Rate) = 1,200 SF Absorption Area
1,200 SF/30 LF (Width) = 40 LF Bed Length
THEREFORE: Construct a 40' Long x 30' Wide Shallow Absorption Bed as Shown Below. Place
Distribution Piping at .5' Below Original Ground Surface. Remove Organic Material and Replace
with Coarse Sand Meeting the Municipal Specification. Place 2" of Insulation and 2' of Cover Over
Bed. Place Topsoil and Revegetate the Completed Mound to Prevent Erosion.
Existing Ground
Topsoil and Revegate Finished Mound
Natural Backfill 2
2" Insulation & ~--] 1
~..........#................................................G..e. o t e xt il e Fabr ....................... ~
0 0 0 0 0 ""'" ~
Drainfield Rook ~, '~
~ Existing Ground
Coarse Sand (See Specification) '~-- -- 1" PVC
Underlying ML 3/16" Holes @ 6' Spacing
6 Per Lateral
3' 6' 6' 6' 6' 3'
NOTE:
TYPICAL BED SECTION
(NO SCALE)
Grade Area Surrounding Bed to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
Minimum 10' Separation From Water Service Line.
DEPTH
(fee0
1
2--
3--
4--
5--
6--
7--
8
9
11
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
z. 700
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: WOODHAVEN SUBDIVISION
PERFORMED FOR: SPINELL HOMES
DATE: I / 2 5 / 13 PROJECT No.:
PARCEL ID#:. TECHNICIAN:
OB/OS
TEST HOLE No. 121
SILTY SAND
WITH VARYING SILT
SM/ML
DAMP TO WET
B OH @ I I. 0' DATE OF MONITORINe:
DATE
/25
A. HARALA
SLOPE
YES
SITE PLAN
SEE SITE PLAN
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
I 12:05 1.25"
2 12:35 50 1.56" .51"
3 12:36 I. 125"
I 4 1:06 30 1.435" .31"
5 1:07 1.25"
6 [:57 30 1.56" .31"
PERCOLATION RATE: 97 (mm/nqCH) PERC. HOLE DIA. 8"
TEST RUN BETWEEN: 3 FT. and 4 FT.
__fINCHES
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. CATEGORY III SEPTIC SYSTEM REQUIRED.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE:. 5/24/16
4700
DEPTH
(feet)
1
2--
3--
4--
5--
6--
11
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519 6650
SOILS LOG - PERCOLATION TEST
LEGALDE$CRIPTION: WOODHAVEN SUBDIVISION No.
PERFORMED FOR:
DATE: 6/I/16
PARCEL ID,g:.
OB/OG
SPINELL HONES
PROIECT No.:
TECHNICIAN:
SILTY SAND
WITH VARYING SILT
SM/ML
DAMP TO WET
WAS GROUND WATER ENCOUNTEKED?
iF YES ~ WHAT DElrDt?
DEPTH TO WATER AFTER MONITORING:
DATE OF MONiTORING: __
BOH @ 1,5.0'
ROBERTS
SLOPE
YES
SITE PLAN
SEE SITE PLAN
DATE READING GROSS TIME NET T,MEI
DwE% ' TOINET DROF
I (MINUTES) I(i~INUTES) I (INCHES) I(INcHEs)
6/I TEST HOLE PRESOAKED PRIOR TO TESTING:
I 1:09 0.65.
2 1:59 ,50 0.88, .25"
,5 1:40 0.50,' ,,
4 2:10 50 0.75, .25
5 2:11 0.65,
J. 6 2:41 30 0.88' .25"
PERCOLATION RATE: 120 (MINtDtCH) PERC. HOLE DIA. 8" .(INCHES)
TEST RUN BETWEEN: 3 FT. and 4 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. CATEGORY III SEPTIC SYSTEM REQUIRED.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 8/I/16/16
August 1,2016
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~e~:
Woodhaven #2, Tract D-1B-A
Absorption Bed Width
Dear Onsite Services Engineer:
The area available for a septic system on the subject lot, which is proposed Lot 11 of
Woodhaven Subdivision No. 3 is limited by several factors including the presence of
groundwater, location of wells on this and surrounding proposed lots and the placement
of the house and driveway. An absorption bed must be placed to insure the separation
from groundwater can be met. The width of the bed must be 30' to provide the
necessary absorption area to meet the design. The ordinance governing septic
systems states the bed width can be greater or lesser than 15' with approval from the
department. We hereby request that approval.
The bed will be accessed with a pressure distribution system. Effluent will therefore be
dispensed uniformly over the area. Effluent will be discharged after undergoing
treatment through an Advantex Treatment System. A minimum of .5' of drainfield rock
will be placed. The bed will be constructed without any ddving or compaction of the bed
by equipment or labor. A bed width as noted above and shown on the Site Plan will not
adversely affect the operating characteristics of the absorption system.
Sincerely,
Michael E. Anderson, P.E.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677,7766 (FAX)
August1,2016
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Woodhaven #2, Tract D-1B-A -( Proposed Lot 11 )
Trench Side Slopes
Dear Onsite Services Engineer:
Absorption system sites on proposed Lot 11, Woodhaven Subdivision No. 3 are limited
by the presence of groundwater and tight soils with few areas acceptable for the
placement of an absorption bed. The most suitable area to place the new bed is
approximately 8' from the 10' easement parallel to the southern lot line. The total
height of the fill for the absorption bed will be approximately 3' above existing ground.
The 3:1 side slope will encroach onto the easement. We therefore request a waiver
allowing the slope to be 2:1. The slope will be covered with topsoil and seeded with
grass. Maintenance will be provided until a flourishing stand of grass is achieved. The
2:1 slope is standard for fill slope requirements in the Municipality. No erosion of the
slope is anticipated once revegetation is complete.
Sincerely,
Michael E. Anderson, P.E.
· ~ 49th ~ ~
•
co-
•-
9�
Municipality of Anchorage _
''` - On-Site Water and Wastewater Program <.;:BA •
(907)343-7904 SAE ETY
Certificate of On-Site Systems Approval
Parcel I.D. 015-282-56 Expiration Date: JLA ity 0 1, ,a 01 7
1. GENERAL INFORMATION
Complete legal description Woodhaven No. 3, Lot 11
Location (site address) 4042 Marcelle Circle Anchorage, AK 99517
Current Property owner(s) Spinell Homes, Inc. Day phone 344-5678
Mailing address 1900 W. Northern Lts. Blvd., #200 Anch., AK 99518
Real Estate Agent Day phone
2. TYPE OF DWELLING:
E Single Family(w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: Four
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: t9 ,I(Ai(,//A M/2() Date: qt2-0
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 36-1g Waiver Fee $
— DateofPayment - la/1M --DateofPayment
Receipt Number 08q7-,3 K 7-3 Receipt Number
COSA# (JW/ , Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E. Date 4/18/2017
DSD SIGNATURE
��`s:r} ms's • g "
�,�000 edu'a i:ie s:'e'ai°o-aav°rva +svori
System #1 Approved for bedrooms
�H I
� tem #2 Approved for bedrooms �rs�J�� �� �- /
Disapproved " 3 pROFFSS10Ra-�
Conditional a tQ3�'4,
approval for y bedrooms, with the following stipulations:
i'n o I A: a rl'� r� �O �� cA rv� I -� c� 1 e 1 a O t
�P2
en a nee r'S n\en�or, 8L11" ed APr;
J
WATER AND
WASTEWATER
1-n r).0nGRAM
By: ► �-V �C,Cz GUc �c� l i nA F_c ,1 u4, J Original Certificate Date:q1211201-7
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet r '• 1. c
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Legal Description: Woodhaven No. 3, Lot 11 Parcel ID:015-282-56
A. WELL DATA
Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y
Date completed 10-27-16 Sanitary seal (Y/N) Y Wires properly protected (YIN) Y
Total depth 121 ft. Cased to 120 ft. Casing height(above ground) >24 in.
FROM WELL LOG AT INSPECTION
Date of test 10-27-16
Static water level 65 ft. ft.
Well production 15 g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate 2.35 mg/L
Arsenic NDug/L Date of sample: 4-5-17 Collected by: Anderson Engrg.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Advantex/FAP/Septic Date installed 12/12-15-16
Tank size 1,500 gal. Number of Compartments 2 Cleanouts(Y/N) Y
Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) Y
Date of pumping New Const. Pumper
C. ABSORPTION FIELD DATA
Date installed 12/12-15/16 Soil rating (g.p.d./ft2 or ft2/bdrm) .5 GPD/SF System type Raised Bed
Length 40 ft. Width 30 ft. Gravel below pipe 'S ft.
Total depth 4.8 ft. Eff. absorption area 1,200 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Const. Results(Pass/Fail) For 4 bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment(past 12 mo.)(Y/N &type) If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (YIN)
"Pump on" level at in. "Pump off' level at in. High water alarm level at in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100'
On adjacent lots >100'
Absorption field on lot >100 On adjacent lots >100
Public sewer main X75 Public sewer manhole/cleanout >100
Sewer/septic service line >25' Holding tank >75'
Animal containment areas >j Manure/animal excrete storage areas ��00
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation Property line Absorption field >j
>10' >10' >100'
Water main Water service line Surface water
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line Building foundation Water main
Water Service line >10Surface water 100 Driveway, parking/vehicle storage >10'
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS
G. ENGINEER'S CERTIFICATION 44.4OF AL 94
I certify that I have determined through field inspections and ,�Q;• .,A • `r`+*�j
review of Municipal records that the above systems are in L'J••• � . ,� ••,� 4�y
conformance with MOA COSA guidelines in effect on this date. ci
s++.• • f,
Michael E. Anderson, P.E.
Engineer's Printed Namep•••• ••••"••' •°
4/18/2017 01 V".•MICHAEL E. ANDERSON . '
Date Y CE-4381 .-
c, .e,.
41.
+4eb,$�f� \�` 4 i
COSA brown sheet 10-10-12.doc