COSA may not be approved without the
berm/swale in place that is required for
the surface water waiver.
Permit Number: 0SP141272
Tax Code Number: 02056139000
Work Type: WelISeptic
Permit Effective Dates: July 22, 2016
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to July 22, 2017
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: RABBIT CREEK VIEW & HEIGHTS
Site Legal Address: RABBIT CREEKVIEW & HEIGHTS BLK 6H LT 2A G:3341
Owner/Address: STEFFENS CLAIRE
PO BOX 101847 ANCHORAGE AK 995101847
Site Mailing Address: 8415 DENISE ClR, Anchorage
Lot Size in Sq Ft: 32978
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to Apd115, a subsurface soil absorption system under construction during.freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions:
1. The driveway must be creating a barrier to overland flow of effluent and the swale between the
house and field must be in place prior to Inspection Report approval.
2. The Engineer needs to do 2 test holes prior to the construction of the septic field to satisfy ERS
requirements. Please submit stamped and signed results with the As-built Inspection Report. If
the results require a design change, construction of the system will stop pending On-Site review
and approval.
3. The finished grade around the septic system is to be graded so that water does not pond.
Received By:
Issued By:
\ `urnr S
Municipality of Anchorage r
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV151150 COSA#: Permit#:OSP141272
PID#: 020-561-39
Legal Description: Rabbit Creek View and Heights Bilk 6H Lt 2A
Engineer: Pannone Engineering Services
Applicant: Claire Steffens
Your request for a waiver of the required 100 feet horizontal separation from the
absorption field and septic tank to the surface water has been approved. The approved separation
distance is 60.0 feet. In addition, the use of Engineered Receiving Soil has been approved.
This waiver approval applies to the proposed absorption field and septic tank only. Any future
upgrade to the on-site wastewater disposal system will require all separation distances be met or
another approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
............................................... ■ ............................. ■ 1
Waiver is Granted: X Waiver is not Granted:
Date: Approved by:
Name of Re wer
....................................................... ■ ................... ■ 1
**** VARIAN C E/WAIVER REVIEW ****
MUNICIPALITY OF 'ANCHORAGE
Community DeveloPment Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE-SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-561-39
Property owner(s) Claire Steffens
Mailing address P.O. Box 101847, Anchorage, AK 99510
Site address 8415 Denise Circle
Day phone
Legal description (Sub'd., Block & Lot) Rabbit Creek View & Heights, Block 6H, Lot 2A
Legal description (Township, Range & Section)
Lot Size 32,976 .Sq. Ft. Number of BedrOoms 3
APPLICATION IS FOR:
([~ all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage ~
APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
TYPE OF DWELLING:
Single Family (SF) []
(w/wo ADU)
Duplex (D) []
Multiple Dwellings []
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUESTI:oR:
Septic to surface Water Distance: 50'
I certify that the above information is correct. I further certify that this is in accordance with
app~licable Mun~C.~, ~ ~ OK ~
(Signature of property owner or authorized agen-'~-~: -
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No. O~IH
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_J- :.: 2.Cc ~'
MUNICIPALITY OF ANCHORAGE
Community Development Department
Mayor Ethan Berkowitz
Phone:907-343-7931
Fax: 907-343-7927
Title 21 Code Selection
For review and approval of my project, ¢CV~H ~3/~
I choose to be regulated by:
[] "Old" Title 21 (expires December 31, 2015)
[] "New" Title 21 (becomes effective January 1, 2014)
I understand that my application will be reviewed and acted on using the provisions of the code version I
have selected, and that this selection is final.*
Printed Name
*Should the petitioner wish to switch the applicable version of code at any time after this form is
subnfitted, a new application is required and new application fees will be assessed. The case will then
be scheduled as a new application in accordance with the cut-off date schedule.
For office use only:
Pemfit/Case Number
10/07/] 5
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-maih steve(~panenRa~<.com
O~tober 07, 2015
Subject: Rabbit Creek View arid Heights, Block 6H, Lot 2A
Well antiseptic System Permit Request
Design Narrative
This is a design narrative for a permit to !..r)stall a well and septic system to be issued for this property. The
proposed systems Will serve an prol~0sed three bedroom (3) bedroom house. Currently the lot is
undeveloped. The surrounding developed lots are served by private wells. There are no wetJs within 100' '
of the proposed septic system.
'Soils. One test hole was performed on this lot by PES in June of 2014, and groundwater was monitored
for at least seven days. Ground water was observed at a depth of 2.6' below the surface in the test
hole monitor tube in October of 2014. Bedrock was not encountered in the test hole. Based on the
results of the percolation tests and overall soils appearance; an application rate of 6
gallons/day/square feet was used for a CAT III wastewater system in the area of the test hole.
2. Soil Absorption System Design.
a. See S~heet 1 of the design package.
3. Surface Water: There is surface water in the form of a creek approximately 50 feet from the proposed
septic tank and 72 feet from the proposed drain field. See waiver request.
4. Topography: The existing topography generally slopes from the south to the north in the area
surrounding the septic System at approximately 8%. There are no steep slopes within 50' of the proposed
drain field. The proposed drain field will maintain 50' separation all steep slopes.
5. Drawing Markings:The Drawings are marked "For MoA Review Only". When written notification that
the review is complete and that there are no further comments is received from MoA On-Site
Department, the note will be removed and "issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of th is o} the surrounding lots.
Mailing: P.O. Box 100~217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272~8218 FAX: (907) 272-8211
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E~maih steve@panengak eom
Subject:
July 25, 2016
Rabbit Creek View and Heights, B6H L2A
Surface Water Waiver and ERS Wgive'r Request
Surface Water Waiver Request. I am requesting a waiver for the separation distance from the septic
system to surface water of approximately 60'. The surface water is approximately 72.8'_+ from the fiekt
and 60.9'+ from the tank. Construction of an earthen berm system in the form of a raised pad for the
house and driveway will extend the overland sheet flow distance to 100'+ from tee proposed system
to the surface water.
2. Waiver Request for use of Engineered Receiving Soil (ERS). I am requesting a w~iver to the 1992 Code to
use the proposed Code Update Section of Engineered Receiving Soils (ERS). Below I will detail my request
justifying the use of ERS:
a. One test hole was excavated by PES in 2014. The soils log is at~ached. Ground wat~? Was monitored :for
through the fall seasonal h'igh a,~d stabilized at 2.6 feet below g¢ound level in October of 2014.
b. This design proposes to use MoA Type II. This interface will be approximately 2.5 feet in depth and will
be compacted to approximately 80 percent to allow free flow of the effluent through it into the native
soil using MoA Waste Water Code application rates. The infiltration area of the interface between the
ERS and the in-situ soil was based on the 30-60 minute per inch percolation rate of the in-situ receiving
soil. A two foot thick filter sand layer will be placed over the MoA Type II material to act as an interface
between the SAS and ERS.
c. The SAS is sized assuming a percolation rate of the ERS soil, assumed 16-30 MPI, which gives an
application rate of 4 GPDSF.
d. The system will protrude above the ground surface. The cover of the system will produce a mound,
which will have at a minimum, three to one side slopes and six inches of organically rich soil to promote
the growth of vegetation. The mound will be vegetated.
e. The in-situ receiving soils were attempted to be percolated, but due to heavy rains, we were unable to
perform an accurate percolation test.. PES did have a sieve analysis performed on the material bya
Certified Geotechnical Engineer, Crowther and Associates. The Sieve Analysis classified this materiat as a
Silty gravelly SAN D (or SM under the Unified Soils Classification system.) The proposed ERS COde limits
the use of ERS in soils classified as GP, GW, SP, or SV~L. The application rate for an SM soil per 18 AAC
72.035(6) Table B is 275 square feetper bedroom (0.55 gpd/sf- Do the math. See Table C 18AAC72) for
a conventional system (which equates to a percolation rate range of 16-30 mpi ur~der Title J.5.65.350).
PES proposes using a Category Ill advanced wastewater system on this property. Based on the assumed
percolation rate of 16-30 mpi, an application rate can be used up to 4 gpd/sf. PES is proposing using a
conservative rate of 2.0 gpd/sf for a CAT Ill system (percolation rate range of 30 to 60 m~i) and a wide
tre. nch.
co~q~ ·
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
The 'proposed installation will not affect the future development of this or the surrounding lots.
Sincerely,
SteYen R. ~annone,
~ner/Civil [ngineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
C 0.4f
\ WELL (P)
1� (NIC)
I � i
ir
Cn
\� Awl ri
BERM (P)
CONSTRUCT BERM / CHANNEL
` 116.6 6� - TO DIRECT ACCIDENTAL EFFLUENT
TH-1
SEPTIC AREA (P) ` 12.7•
DENISE CIRCLE
DRAIN FIELD (P)
-M 25LF x 5.0'W x 0.5'ED x +1 .5 TD
WITH 2' SAND AND 2.5' MoA TYPE II /
REMOVE AND REPLACE FOR RESERVE
�r
A)
V
z- /
0
WELL (P) I /
NOTES:
CHANGE ORDER
DRAWN BY:
DRM
PLAN
USE OVERFLOW MIN. 100' BEFORE
NO - POSSIBLE CONTACT WITH STREAM
20 s" L T 2A/ /
7s-7
60.9 I I
Q,
150 g ADVANTEx TANK (P) 3AB
WITH AX20 POD
& AUX PUMP VAULT
SEPTIC AREA (P)
PANNONE ENG
P.O. BOX 100217 ANCHOR,
PHONE (907) 272-8218 FAX
LLC
99510
272-8211
RABBIT CREEK VIEW & HEIGHTS, BLOCK 6H, LOT
CLAIRE STEFFENS
DENISE CIRCLE
ANCHORAGE. AK 99516
I
M —AA_—\
HLA.o11, 17/25/2016
.... ... . .. ... P.I.D. NO
-561-39
81
Steven 88149 one PERMIT N0.
CE 49 / OSPI 41272
'�tiF�PROfES9pNP Sheet
1 OF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIER IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ·
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USER IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS AND IN ACCORDANCE WITH AMC 15.65.
2. SCOPE OF WORk;: INSTALL NEW 15009 ADVANTEX TANk; WiTH AX20 POD, AND SOIL ABSORPTION SYSTEM. INSTALL WELL.
5. GROUNDWATER WAS MONITORED AT 2.6 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. NO
APPARENT WATER TABLE WAS OBSERVED IN ANY OF THE EXCAVATIONS kESS THAN 2.6 FEET BELOW EXISTING GRADE.
WEIGHT CALCULATIONS / . / / ~FILTER ~ABRIg
Buoyant Force: Weight of Wate~isplaced · / / /~1.25" ~ PERF PIPE W/
Assume water ~ -2 ff f~ Seasonal High x o[*~4 s~ ~~
Assume tank hcno weight - I , ql. - -
Weight of 2' ~saturated Soil 120 PCF $o ~ 2~ -
(2'x4.83x1~120 PCF = 13,910 ~ Down / ~o~4/~;
(120 P~ - 62.4 PCF)=57.6 p~ M~Nt~U~ Zs' MC TYPE, riLL i 7/8/~4
(2'X4~3X12)X57.6 PCF = 6,6~ ¢ Down EDPTI~M ~ 10 0
/ z ~
% UI~ 2' ~NO FILTER
j 15009ADVANTEX r --
TANK W/~20/ MfN 2.5' MOA ~PE II
DESIGN PARAMETERS ABBREVIATIONS
DESIGN PARAMETERS ERS - IN-SITU INTERFACE CU COPPE.R
PRIMARY SEPTIC SYSTEM NO. BEDROOM: 5 (450 9pd) DiP DUCTILE IRON PiPE
DRAIN FIELD - ERS iNTERFACE PERC RATE: 30-60 MPI TH TEST HOLE
NO. BEDROOM: 5 (450 gpd) SOIL RATING: 2 OPD/SF FC FOUNDATION CLEAN OUT
TANK SIZE: 15009 ADVANTEX AREA RQD: 225 SF T~ TANK CLEAN OUT NO,
W/ AX20 ~ AUX PUMP VAULT C~ CLEAN OUT NO.
PERC RATE: 6-15 MPJ USE: M~ M~NITOR TUB~ NO
SOIL RATING: 4 GPD/SF 27 LF X 9.0' WIDE x 2.5' THICK RJ. RIGID INSU~TION
AREA RQO: ~ 12.5 SF TOTAL AREA: 2~3 $F
SYS. TYPE: WIDE TRENCH 0.5'ED DCO DOUBLE CLEAN OUT
MIN LENGTH: 22.5 LF DV D[VERTER VALVE
LEGEND FS FLOW SPUTTER
USE: ~W~ WATER LINE/ BFO BELOW FINISH GRADE
25 LF X 5.0' WIDE, 0.5' E D;, +1,5' TD WELL RADIUS OG ORIGINAL GRADE
WITH 2.0' SAND PG FiNiSH GRADE
TOTAL AREA: 125.0 SF ~ SS ~ NEW SEPTIC TS~V TOPSOIL AND VEGETATE
CHANCE
ORDER
P.O.
PHONE (907) 272-8218 FAX (907) 272-821~ ~... ~..~ ¢~ sce~e
PLD. NO
DRM RABSIf CREEK VIEW a HEIGHTS, 8LOCK 6H. LOT 2A- ~"~¢~k'~&'~ as0-869-59
CLAIRE STEFFENS i,~' CE a~49 .~ PERMIT
DESIGN DETAILS ANCHORACE, AK 99516 ~Sg~S~{X~,,._-.,~,~ Sheet
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
3 ~ 10~4/2014 [ X,
~ 6~0/2014
GM SIL~ GRAVEL /~ ·
WAS GROUND WATER SLOPE
14 ~ ENCOUNTERED? Y
15 ~ IF YEs, AT WHAT TH
DEPTH? SEEP ~ -4.5' X
17 -- DEPTH TO WATER AFTER
MONITORING? :4.1'-
18 DATE: 7/8114
WATER
DATE PERFORMED: 6/30/14 DEPTH T~ WATER AFTER CLOCK NETTIME LEVEL NETDROP
MONITORING? -2.6'- READING DATE TIME
READING
BATE: 10/24/14
~ 6/30/14 ! 2;16 --- 3.65 ---
2 2:26 10 MIN 6.82 3.17
3 2:28 --- 3.67 ~ ---
4 2:38 10 MIN 6.81 3.14
5 2:40 --- 3.41 --
s 2:50 10 MIN 6.51 3.10
PEROLATIQN ~TE 3.2 (mi~/i~ch) PERC HOLE DIAMETER 6 inches
TEST RUN BE~EEN 2 FT AND 3
COMMENTs: Test hole excavated by the Lot Owner. Prec hole was preso~ed.
Test ~n for one hour. ~st 3 readin~ reposed
PERPORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCO~CE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
ENG
I I/~ 9/2o~ 5
FOR CONSTRUCTION P.0. 80~ 102954 ANCHORAGE, AK 99510~ -' '-
PHONE (907)272-8218 FAX (907)272-8211
NTS
RABBIT CREEK VrEW & HEIGHTS, BLOCK 6H, LOT 2A~ ~'~; ~W6&b'~ 020-561-39
CLAIRE STEFFENS r~,~L~ CE 8~9 ..~ PERMIT NO
DENISE CIRCLE ,~... . ...~
READING DATE CLOCK WATER
TIME NET TIME LEVEL NETDROP
READING
I 6/30/14 2:16 --- 3.65 --.
2 2:26 10 MIN 6.82 3.17
3 2:28 ..- 3.67 ...
4 2:38 10 MIN 6.81 3.14
5 2:40 ___ 3.41 .-
$ 2:50 10 MIN 6.51 3.10
ADVAN TEX DESIGN ,.
ABVANTEX
24" PASSIVE
4" JIM CAP AX20 POD~ INSULATED .
SLIDE SECTION
. OF 6" PIPE
OVER THIS CONNECTION
TO PROVIDE
SHEER PROTECTION 10'
EXTEND TO
BRIDGE EXCAVATION
TANK BEDDING DETAIl_ BUOYANCY CALCULATION
20' ~ /--RISER
~,~R E POS E // POD WEIGHT CALCULATIONS
/ / Buoyont Force = Weigh( of Weter Displ<]ced
/,//-
NATIVE: 560CF-RISER 8.16CF-POD 65.3CF= 286 5CF (((Plx(5.5)~2/4)xlO)+17.6)x62 ¢ PCF = 15,059 #Up
4, ~,'t~/'~//,I ! ~/~'~//',~,/ - COUNTER WEIGHT
~' ~,'5~./1 i (~t¢ Assume w<]ter @ surfoce - ell soil sotoroteO
' :', ",: ' , -. ,' . ' Assume ongle of repose = 20 Degree (WORSE CASE)
_..~I~ ~'~ .-~ ~ TYPE I1:159CF-RISER 6,28CF = 152.7CF Assume bedding does not odd to force down
~J-¢~' ~ .~ , ~ Weigh[ of tonk = 1,~00 #
0¢'6 ~ ~ i ~ ~BED TANK W/ Weigh[ of MoA Type II (188 PCF - 62.4 PCF)=72.6 pcf
' ~ ]:~ SEWER ROCK 182.7CF x 72.6 PCF = 11,086 ~ Dow~
Weight of Not(ye Soil (120 RCF - 62.4 PCF)=57.6 pdt
/J ~'- 2' TYP.. : 286.5CF x 57.6 PCF = 16,502 # Down
Tot¢l Weight on Tenk = 28,988 # OK!
~- 1500 ADVANTEX TANK '
,O,ES: PANNONE ENG SVC, LLC
CHANGE ORDER P,0. BOX 100217 ANCHORAGE, AK 99510 ~'~ 8/1/2016
PHONE (907) 272-8218 FAX (907) 272-8211
',*'/,
RABBI~ CREEK VIEW & HEIGHTS, BLOCK CH, LOT 2~ ~--~~__~ P.hD. NO
r _~.~..~.%,,.~.~.. .._.~-%. ........... ~ 020-561-59
r~ -Steven R. Pdnnome
CLAIRE STEFFENS ;~-. CE 81~9 '~,~- :ERMIT NO.
DENISE CIRCLE
SITE SECTION ANCHORAGE, AK 99516 ll{?~0~ddo~x?~ Sheet
~'~._~. 4 OF 4
040. 002 Crowther Associates
Client: Pannone Engineering Seryices
Project: Rabbit Creek View and Heights Block 6H Lot 2A
Date: July 24; 20t6
Particle Size Distribution Table
Sample Source
Block 6H
Lot 2A
Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer
3 inch 100
1-1/2 inch 100
h inch 89
~t 70
#10 62
#40 52
#100 41
#200 37
0.02 mm
Classification
Silty Sand
(SM)
1632 Bellevue Circle/Anchorage, Alaska 99515
Telephone (907) 349-2198 / E mail: crowther~alaska net
TEST HOLE 2
OR ORGANICS
1
2
3:1
7/8/2014
4 7
SOILS LOG - PERCOLATION TEST
SLOPE
5
GM SILTY GRAVEL
6 W/ TIVER ROCKS X
TH
7
8
9 BOH
10
11
12
13
14
15
16
17
18
DATE PERFORMED: 6/30/2014
WAS GROUND WATER
ENCOUNTERED? Y
IF YES, AT WHAT
DEPTH? SEEP () -4.5'
DEPTH TO WATER AFTER
MONITORING? -4.1'-
DATE: 7/8/14
WEIGHT CALCULATIONS
Buoyant Force = Weight of Water Displaced
((Plx(4.83)^2/4)xl2)x62.4 PCF = 13,720 # Up
COUNTER WEIGHT
Assume water @ -2 ft for Seasonal High
Assume angle of repose = 0 Degree
Assume bedding does not add to force down
Assume tank has no weight
Weight of 2' Unsaturated Soil 120 PCF
(2'x4.83x12)x120 PCF = 13,910 # Down
Weight of 2' of Saturated Native Soil
(120 PCF - 62.4 PCF)=57.6 pcf
(2'x4.83x12)x57.6 PCF = 6,674 # Down
Total Weight on Tank = 20,584 # OK!
TH
X
READING DATE
CLOCK
TIME
NET TIME
WATER
LEVEL
READING
NET DROP
1 6/30/14
2:16
---
3.65
---
2
2:26
10 MIN
6.82
3.17
3
2:28
---
3.67
---
4
2:38
10 MIN
6.81
3.14
s
2:40
---
3.41
---
6 1 1
2:50
1 10 MIN
6.51
3.10
PEROLATION RATE 3.2 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 2 FT AND 3 FT
COMMENTS: Test hole excavated by the Lot Owner. Prec hole was presoaked.
Test run for one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES:
PANNONE ENG SVC' LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE PHONE (907) 272-8218 FAX (907) 272-8211
-�oF A� ��l
q l)
r �. S
j �. � +�
A'
..... .%. JJ
teven ...... R .. .. ... /
R. Pannone
CE 8149
s -SAW
,�ITF�'FOp �`��'r
1, ROFESSQO
Date
8/14/2014
For Construction
Scale
NTS
P.I.D. NO
- 61-39
RABBIT CREEK VIEW & HEIGHTS, BLOCK 6H, LOT 2AS
CLAIRE STEFFENS
DENISE CIRCLE
ANCHORAGE, AK 99516
PERMIT NO.
SOILS LOG
sheet
3 OF 3
2016 029522
Recording District 301 Anchorage~
07/22/2016 10:16 AU Page 1 of
GRANT OF EASEMENT
This easement agreement is made between Claire Steffens, whose address P.O.Box
101847, Anchorage, Alaska (Grantor), owner of the land described as Lot lA, Block 6H,
Rabbit Creek View and Rabbit Creek Heights Subdivision, (herein Property) according to the
Plat No. 2004-91, records of the Anchorage recording District, Third Judicial District, State of
Alaska, for good and valuable consideration, the receipt whereof is hereby acknowledged,
and does hereby grant unto Claire Steffens, whose address P.O.Box 101847, Anchorage,
Alaska (Grantor), owner of the land described as Lot 2A, Block 6H, Rabbit Creek View and
Rabbit Creek Heights' Subdivision, according to the Plat No. 2004-91, records of the
Anchorage recording .District, Third Judicial District, State of Alaska, the following grant of
easement: described as:
, A perpetual, non-exclusive right of way, to provide access by a trail not to exceed ten
(10) feet in width for the construction, maintenance, repair, removal and inspection of a
water well serving exclusively Lot 2A, Block 6H, Rabbit Creek View and Rabbit Creek
Heights Subdivision, Anchorage: and
A perpetual right to construct, install, operate, maintain, repair, inspect, use and
remove a water well, including all facilities ( eg. casing, pumps, water line and electric line)
needed to operate said well, in, under, upon, about, over and through Lot lA, Block 6H,
Rabbit Creek View and' Rabbit Creek Heights Subdivision, Anchorage, Alaska,said well to
serve only Lot 2A, Block 6H, Rabbit Creek View and Rabbit Creek Subdivision.
Said easement more particularly described as:
An easement depicted on the attached survey prepared by Lee Karabelnikof, Reg.
Land Surveyor No. 3143-S, dated July 21, 2016, having the dimensions as indicated by the
line data thereon, an area of approximately 770 square feet.
1. The easement granted hereby shall not in any manner be dedicated for, or subject
to, use by the public. The use of this easement shall be exclusive to Lot 2A, Block 6H,
Rabbit Creek View and Rabbit Creek Heights Subdivision. Within this easement, rock, soil,
sand, gravel, and vegetation may be excavated and removed to construct, improve, maintain
and repair the trail area.
2. Grantee may maintain, at Grantee's sole expense, the well access trail descibed with
particularity above, for the purpose of effectuating the Grant. Grantor may not place
permanent structures over such trail or otherwise make access to the well impracticable.
The trail may not exceed 10 feet in width and may be permanently
surfaced only with vegetative material.
3. The Easement granted and created is intended to and shall run with the land, with
the benefit of the easement appurtenant to the respective dominant parcel and the burden of
the easement appurtenant to the servient parcel. This Easement shall be binding upon and
inure to the benefit of the parties successors and assigns, heirs, beneficiaries and personal
representatives and be perpetual.
4. This Easeme.~t shall be governed by, and construed and enforced in accordance
with the laws of the State of Alaska.
SIGNED on this the~ I day of July 20'16
GRANTOR: Claire Steffens
GRANTEE: Claire S.;I;effens
THIRD JUDICIAL DISTRICT ) ss.
STATE OF ALASKA )
The foregoin~(~l~l//~ment was acknowledged before me this ?-.t ~T day of July 2016, by
~- i NOTARY i ~ NOTARY ,rOI. lC ,N ANO ,OR THE STATE O, ALASKA
THIRD J~J~,~iCT ) SS.
STATE OF A~RSR,~' )
The foregoing instrument was acknowledged before me this ~'[ 5q-. day of July 2016, by
NOT d ,N AND ,OR THE STATE O, A AS A
~ ('~Oq¢~-~} ~ M~ommJssionExpires'
Return t~~. ~0~847, Anchorage, AK 995~0-~847
Page 2 0f 3
2016 - 029522 - 0
?
/
/
/
,/
~J SO9'(
.ON
b
,¢
,0£
I
I
II I--
"T"
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY OF ANCHORAGE
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this .
~ Dayof /[~te~L*-~ of20/--q, byandbetween(r?,/~ I? e ~te:~tOj
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration ofthe mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as
located at (legal description).
2. Definitions.
Alteration. Any change to the design or function of an AWWTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On-Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code(hereinafter, "AMC") 15.65. These approvals certify that
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included
in the original design which would allow the AWWTS to continue to
perform as designed.
Permit. An On-Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AWWTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance ora
COSA, and shall continue ~vhile the AWWTS is in use or is operational or until the
property is sold or title is transferred by the owner and a new COSA is issued to the
new owner or transferee of the property.
4. Alterations, Installation and Removal of Additional Equipment. Prior to
performing any alterations to an AWWTS, the owner agrees to obtain an On-site
· Wastewater Disposal Permit fi:om the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the OWner shall
maintain their AWWTS in a satisfaCtOry condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service a~reement with an AW~VTS
service and maintenance provider approved by the muincipality and the
manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it
shall be the responsibility of the Owner during the term of tins Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay
for any and ali: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and (5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, roles
and orders for the AWWTS.
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to tins
information.
D. Owner acknowledges that the frae for failing to maintain and repair an AWWTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner age_es to gran~ the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On-Site Systems Approval.
H. Owner agrees that the AWWTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Murficipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AWWTS.
I. Owner agrees to provide and maintain a telephone connection to the AWWTS as
required by the AWWTS approval.
6. Nonwalver. The failure of either party at any time to enfome a provision of th/s
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to ~nforce each and
every provision hereof.
7, Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
b. Municipality: Director, Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising fi:om this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anch6mge. The laws of the State of Alaska shall
govern the rights and obligatinns of the parties under this Mainte~}ance and Repair
Agreement.
9. Severabilit¥. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
O~R ~
_-..4 ,/3/
By: ~------~'-'~ ~~--4:::~ (siguature)
(print name)
STATE OF ALASKA
THIRD JUDICIAL DISTRICT
The foreg~
20 I,r, ~(
'x
My.
MUBIICIPALITY:
)
tg instrument was acknowledged before me this ~0 day of ~J/~.,
.,- ~ ............. ~Z ~..
'
',,,,,5~ [~,~,,'
(signature) Date:
(prim name) Title:
Register 163, July 2002 ENVIRONMENTAL CONSERVATION
Co* l
TABLE B. ABSORPTION FIELD AREA REQUIREMENTS
FOR UNIFIED SOIL CLASSIFICATION
Minimum inf'dtrative area,*
Unified Class Description measured in square feet per
bedroom
GW* Well-graded gravels 85
GP* Poorly-graded gravels 115
SW Well-graded sands 125
SP Poorly-graded sands 150
GM** Silty gravels 225
SM** Silty sands 275
*GW and GP soils are unsuitable for use in absorption areas unless a two-foot thick layer of
sand, meeting the requirements of 18 AAC 72.260(a)(4)(D), Table C, Noie 1, is placed
between the distribution rock and the receiving soil; the department will waive this
requirement if a waiver does not threaten public health, public and private water systems, or
the environment, and in accordance with 18 AAC 72.060.
** Use of these soils in absorption areas require a percolation test by a registered engineer,
conducted in accordance with 18 AAC 72.265(9).
(7) the system complies with the separation distances set out in 18 AAC 72.020;
(8) the ground surface slope is less than 25 percent for trenches, and less than
five percent for beds;
(9) as shown in Figure 1 of this subsection, at least 50 feet separates any part of
the soil absorption system from any slope greater than 25 percent, whether man-made or natural,
with a drop in the shrface height greater than 10 feet; and
12