Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 6H LT 2ARabbit Creek View & Heights Block 6H Lot 2A #020-561-39 COSA may not be approved without the berm/swale in place that is required for the surface water waiver. Permit Number: 0SP141272 Tax Code Number: 02056139000 Work Type: WelISeptic Permit Effective Dates: July 22, 2016 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial to July 22, 2017 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: RABBIT CREEK VIEW & HEIGHTS Site Legal Address: RABBIT CREEKVIEW & HEIGHTS BLK 6H LT 2A G:3341 Owner/Address: STEFFENS CLAIRE PO BOX 101847 ANCHORAGE AK 995101847 Site Mailing Address: 8415 DENISE ClR, Anchorage Lot Size in Sq Ft: 32978 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to Apd115, a subsurface soil absorption system under construction during.freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. The driveway must be creating a barrier to overland flow of effluent and the swale between the house and field must be in place prior to Inspection Report approval. 2. The Engineer needs to do 2 test holes prior to the construction of the septic field to satisfy ERS requirements. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. 3. The finished grade around the septic system is to be graded so that water does not pond. Received By: Issued By: \ `urnr S Municipality of Anchorage r P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV151150 COSA#: Permit#:OSP141272 PID#: 020-561-39 Legal Description: Rabbit Creek View and Heights Bilk 6H Lt 2A Engineer: Pannone Engineering Services Applicant: Claire Steffens Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank to the surface water has been approved. The approved separation distance is 60.0 feet. In addition, the use of Engineered Receiving Soil has been approved. This waiver approval applies to the proposed absorption field and septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ............................................... ■ ............................. ■ 1 Waiver is Granted: X Waiver is not Granted: Date: Approved by: Name of Re wer ....................................................... ■ ................... ■ 1 **** VARIAN C E/WAIVER REVIEW **** MUNICIPALITY OF 'ANCHORAGE Community DeveloPment Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE-SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-561-39 Property owner(s) Claire Steffens Mailing address P.O. Box 101847, Anchorage, AK 99510 Site address 8415 Denise Circle Day phone Legal description (Sub'd., Block & Lot) Rabbit Creek View & Heights, Block 6H, Lot 2A Legal description (Township, Range & Section) Lot Size 32,976 .Sq. Ft. Number of BedrOoms 3 APPLICATION IS FOR: ([~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage ~ APPLICATION IS AN: Initial [] Upgrade [] Renewal [] TYPE OF DWELLING: Single Family (SF) [] (w/wo ADU) Duplex (D) [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUESTI:oR: Septic to surface Water Distance: 50' I certify that the above information is correct. I further certify that this is in accordance with app~licable Mun~C.~, ~ ~ OK ~ (Signature of property owner or authorized agen-'~-~: - Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. O~IH Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_J- :.: 2.Cc ~' MUNICIPALITY OF ANCHORAGE Community Development Department Mayor Ethan Berkowitz Phone:907-343-7931 Fax: 907-343-7927 Title 21 Code Selection For review and approval of my project, ¢CV~H ~3/~ I choose to be regulated by: [] "Old" Title 21 (expires December 31, 2015) [] "New" Title 21 (becomes effective January 1, 2014) I understand that my application will be reviewed and acted on using the provisions of the code version I have selected, and that this selection is final.* Printed Name *Should the petitioner wish to switch the applicable version of code at any time after this form is subnfitted, a new application is required and new application fees will be assessed. The case will then be scheduled as a new application in accordance with the cut-off date schedule. For office use only: Pemfit/Case Number 10/07/] 5 Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-maih steve(~panenRa~<.com O~tober 07, 2015 Subject: Rabbit Creek View arid Heights, Block 6H, Lot 2A Well antiseptic System Permit Request Design Narrative This is a design narrative for a permit to !..r)stall a well and septic system to be issued for this property. The proposed systems Will serve an prol~0sed three bedroom (3) bedroom house. Currently the lot is undeveloped. The surrounding developed lots are served by private wells. There are no wetJs within 100' ' of the proposed septic system. 'Soils. One test hole was performed on this lot by PES in June of 2014, and groundwater was monitored for at least seven days. Ground water was observed at a depth of 2.6' below the surface in the test hole monitor tube in October of 2014. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of 6 gallons/day/square feet was used for a CAT III wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See S~heet 1 of the design package. 3. Surface Water: There is surface water in the form of a creek approximately 50 feet from the proposed septic tank and 72 feet from the proposed drain field. See waiver request. 4. Topography: The existing topography generally slopes from the south to the north in the area surrounding the septic System at approximately 8%. There are no steep slopes within 50' of the proposed drain field. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings:The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "issued for Construction" drawings will be issued. The proposed installation will not affect the future development of th is o} the surrounding lots. Mailing: P.O. Box 100~217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272~8218 FAX: (907) 272-8211 Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E~maih steve@panengak eom Subject: July 25, 2016 Rabbit Creek View and Heights, B6H L2A Surface Water Waiver and ERS Wgive'r Request Surface Water Waiver Request. I am requesting a waiver for the separation distance from the septic system to surface water of approximately 60'. The surface water is approximately 72.8'_+ from the fiekt and 60.9'+ from the tank. Construction of an earthen berm system in the form of a raised pad for the house and driveway will extend the overland sheet flow distance to 100'+ from tee proposed system to the surface water. 2. Waiver Request for use of Engineered Receiving Soil (ERS). I am requesting a w~iver to the 1992 Code to use the proposed Code Update Section of Engineered Receiving Soils (ERS). Below I will detail my request justifying the use of ERS: a. One test hole was excavated by PES in 2014. The soils log is at~ached. Ground wat~? Was monitored :for through the fall seasonal h'igh a,~d stabilized at 2.6 feet below g¢ound level in October of 2014. b. This design proposes to use MoA Type II. This interface will be approximately 2.5 feet in depth and will be compacted to approximately 80 percent to allow free flow of the effluent through it into the native soil using MoA Waste Water Code application rates. The infiltration area of the interface between the ERS and the in-situ soil was based on the 30-60 minute per inch percolation rate of the in-situ receiving soil. A two foot thick filter sand layer will be placed over the MoA Type II material to act as an interface between the SAS and ERS. c. The SAS is sized assuming a percolation rate of the ERS soil, assumed 16-30 MPI, which gives an application rate of 4 GPDSF. d. The system will protrude above the ground surface. The cover of the system will produce a mound, which will have at a minimum, three to one side slopes and six inches of organically rich soil to promote the growth of vegetation. The mound will be vegetated. e. The in-situ receiving soils were attempted to be percolated, but due to heavy rains, we were unable to perform an accurate percolation test.. PES did have a sieve analysis performed on the material bya Certified Geotechnical Engineer, Crowther and Associates. The Sieve Analysis classified this materiat as a Silty gravelly SAN D (or SM under the Unified Soils Classification system.) The proposed ERS COde limits the use of ERS in soils classified as GP, GW, SP, or SV~L. The application rate for an SM soil per 18 AAC 72.035(6) Table B is 275 square feetper bedroom (0.55 gpd/sf- Do the math. See Table C 18AAC72) for a conventional system (which equates to a percolation rate range of 16-30 mpi ur~der Title J.5.65.350). PES proposes using a Category Ill advanced wastewater system on this property. Based on the assumed percolation rate of 16-30 mpi, an application rate can be used up to 4 gpd/sf. PES is proposing using a conservative rate of 2.0 gpd/sf for a CAT Ill system (percolation rate range of 30 to 60 m~i) and a wide tre. nch. co~q~ · Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 The 'proposed installation will not affect the future development of this or the surrounding lots. Sincerely, SteYen R. ~annone, ~ner/Civil [ngineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 C 0.4f \ WELL (P) 1� (NIC) I � i ir Cn \� Awl ri BERM (P) CONSTRUCT BERM / CHANNEL ` 116.6 6� - TO DIRECT ACCIDENTAL EFFLUENT TH-1 SEPTIC AREA (P) ` 12.7• DENISE CIRCLE DRAIN FIELD (P) -M 25LF x 5.0'W x 0.5'ED x +1 .5 TD WITH 2' SAND AND 2.5' MoA TYPE II / REMOVE AND REPLACE FOR RESERVE �r A) V z- / 0 WELL (P) I / NOTES: CHANGE ORDER DRAWN BY: DRM PLAN USE OVERFLOW MIN. 100' BEFORE NO - POSSIBLE CONTACT WITH STREAM 20 s" L T 2A/ / 7s-7 60.9 I I Q, 150 g ADVANTEx TANK (P) 3AB WITH AX20 POD & AUX PUMP VAULT SEPTIC AREA (P) PANNONE ENG P.O. BOX 100217 ANCHOR, PHONE (907) 272-8218 FAX LLC 99510 272-8211 RABBIT CREEK VIEW & HEIGHTS, BLOCK 6H, LOT CLAIRE STEFFENS DENISE CIRCLE ANCHORAGE. AK 99516 I M —AA_—\ HLA.o11, 17/25/2016 .... ... . .. ... P.I.D. NO -561-39 81 Steven 88149 one PERMIT N0. CE 49 / OSPI 41272 '�tiF�PROfES9pNP Sheet 1 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIER IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF · ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USER IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND IN ACCORDANCE WITH AMC 15.65. 2. SCOPE OF WORk;: INSTALL NEW 15009 ADVANTEX TANk; WiTH AX20 POD, AND SOIL ABSORPTION SYSTEM. INSTALL WELL. 5. GROUNDWATER WAS MONITORED AT 2.6 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. NO APPARENT WATER TABLE WAS OBSERVED IN ANY OF THE EXCAVATIONS kESS THAN 2.6 FEET BELOW EXISTING GRADE. WEIGHT CALCULATIONS / . / / ~FILTER ~ABRIg Buoyant Force: Weight of Wate~isplaced · / / /~1.25" ~ PERF PIPE W/ Assume water ~ -2 ff f~ Seasonal High x o[*~4 s~ ~~ Assume tank hcno weight - I , ql. - - Weight of 2' ~saturated Soil 120 PCF $o ~ 2~ - (2'x4.83x1~120 PCF = 13,910 ~ Down / ~o~4/~; (120 P~ - 62.4 PCF)=57.6 p~ M~Nt~U~ Zs' MC TYPE, riLL i 7/8/~4 (2'X4~3X12)X57.6 PCF = 6,6~ ¢ Down EDPTI~M ~ 10 0 / z ~  % UI~ 2' ~NO FILTER j 15009ADVANTEX r -- TANK W/~20/ MfN 2.5' MOA ~PE II DESIGN PARAMETERS ABBREVIATIONS DESIGN PARAMETERS ERS - IN-SITU INTERFACE CU COPPE.R PRIMARY SEPTIC SYSTEM NO. BEDROOM: 5 (450 9pd) DiP DUCTILE IRON PiPE DRAIN FIELD - ERS iNTERFACE PERC RATE: 30-60 MPI TH TEST HOLE NO. BEDROOM: 5 (450 gpd) SOIL RATING: 2 OPD/SF FC FOUNDATION CLEAN OUT TANK SIZE: 15009 ADVANTEX AREA RQD: 225 SF T~ TANK CLEAN OUT NO, W/ AX20 ~ AUX PUMP VAULT C~ CLEAN OUT NO. PERC RATE: 6-15 MPJ USE: M~ M~NITOR TUB~ NO SOIL RATING: 4 GPD/SF 27 LF X 9.0' WIDE x 2.5' THICK RJ. RIGID INSU~TION AREA RQO: ~ 12.5 SF TOTAL AREA: 2~3 $F SYS. TYPE: WIDE TRENCH 0.5'ED DCO DOUBLE CLEAN OUT MIN LENGTH: 22.5 LF DV D[VERTER VALVE LEGEND FS FLOW SPUTTER USE: ~W~ WATER LINE/ BFO BELOW FINISH GRADE 25 LF X 5.0' WIDE, 0.5' E D;, +1,5' TD WELL RADIUS OG ORIGINAL GRADE WITH 2.0' SAND PG FiNiSH GRADE TOTAL AREA: 125.0 SF ~ SS ~ NEW SEPTIC TS~V TOPSOIL AND VEGETATE CHANCE ORDER P.O. PHONE (907) 272-8218 FAX (907) 272-821~ ~... ~..~ ¢~ sce~e PLD. NO DRM RABSIf CREEK VIEW a HEIGHTS, 8LOCK 6H. LOT 2A- ~"~¢~k'~&'~ as0-869-59 CLAIRE STEFFENS i,~' CE a~49 .~ PERMIT DESIGN DETAILS ANCHORACE, AK 99516 ~Sg~S~{X~,,._-.,~,~ Sheet SOILS LOG - PERCOLATION TEST TEST HOLE 1 3 ~ 10~4/2014 [ X, ~ 6~0/2014 GM SIL~ GRAVEL /~ · WAS GROUND WATER SLOPE 14 ~ ENCOUNTERED? Y 15 ~ IF YEs, AT WHAT TH DEPTH? SEEP ~ -4.5' X 17 -- DEPTH TO WATER AFTER MONITORING? :4.1'- 18 DATE: 7/8114 WATER DATE PERFORMED: 6/30/14 DEPTH T~ WATER AFTER CLOCK NETTIME LEVEL NETDROP MONITORING? -2.6'- READING DATE TIME READING BATE: 10/24/14 ~ 6/30/14 ! 2;16 --- 3.65 --- 2 2:26 10 MIN 6.82 3.17 3 2:28 --- 3.67 ~ --- 4 2:38 10 MIN 6.81 3.14 5 2:40 --- 3.41 -- s 2:50 10 MIN 6.51 3.10 PEROLATIQN ~TE 3.2 (mi~/i~ch) PERC HOLE DIAMETER 6 inches TEST RUN BE~EEN 2 FT AND 3 COMMENTs: Test hole excavated by the Lot Owner. Prec hole was preso~ed. Test ~n for one hour. ~st 3 readin~ reposed PERPORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCO~CE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ENG I I/~ 9/2o~ 5 FOR CONSTRUCTION P.0. 80~ 102954 ANCHORAGE, AK 99510~ -' '- PHONE (907)272-8218 FAX (907)272-8211 NTS RABBIT CREEK VrEW & HEIGHTS, BLOCK 6H, LOT 2A~ ~'~; ~W6&b'~ 020-561-39 CLAIRE STEFFENS r~,~L~ CE 8~9 ..~ PERMIT NO DENISE CIRCLE ,~... . ...~ READING DATE CLOCK WATER TIME NET TIME LEVEL NETDROP READING I 6/30/14 2:16 --- 3.65 --. 2 2:26 10 MIN 6.82 3.17 3 2:28 ..- 3.67 ... 4 2:38 10 MIN 6.81 3.14 5 2:40 ___ 3.41 .- $ 2:50 10 MIN 6.51 3.10 ADVAN TEX DESIGN ,. ABVANTEX 24" PASSIVE 4" JIM CAP AX20 POD~ INSULATED . SLIDE SECTION . OF 6" PIPE OVER THIS CONNECTION TO PROVIDE SHEER PROTECTION 10' EXTEND TO BRIDGE EXCAVATION TANK BEDDING DETAIl_ BUOYANCY CALCULATION 20' ~ /--RISER ~,~R E POS E // POD WEIGHT CALCULATIONS / / Buoyont Force = Weigh( of Weter Displ<]ced /,//- NATIVE: 560CF-RISER 8.16CF-POD 65.3CF= 286 5CF (((Plx(5.5)~2/4)xlO)+17.6)x62 ¢ PCF = 15,059 #Up 4, ~,'t~/'~//,I ! ~/~'~//',~,/ - COUNTER WEIGHT ~' ~,'5~./1 i (~t¢ Assume w<]ter @ surfoce - ell soil sotoroteO ' :', ",: ' , -. ,' . ' Assume ongle of repose = 20 Degree (WORSE CASE) _..~I~ ~'~ .-~ ~ TYPE I1:159CF-RISER 6,28CF = 152.7CF Assume bedding does not odd to force down ~J-¢~' ~ .~ , ~ Weigh[ of tonk = 1,~00 # 0¢'6 ~ ~ i ~ ~BED TANK W/ Weigh[ of MoA Type II (188 PCF - 62.4 PCF)=72.6 pcf ' ~ ]:~ SEWER ROCK 182.7CF x 72.6 PCF = 11,086 ~ Dow~ Weight of Not(ye Soil (120 RCF - 62.4 PCF)=57.6 pdt /J ~'- 2' TYP.. : 286.5CF x 57.6 PCF = 16,502 # Down Tot¢l Weight on Tenk = 28,988 # OK! ~- 1500 ADVANTEX TANK ' ,O,ES: PANNONE ENG SVC, LLC CHANGE ORDER P,0. BOX 100217 ANCHORAGE, AK 99510 ~'~ 8/1/2016 PHONE (907) 272-8218 FAX (907) 272-8211 ',*'/, RABBI~ CREEK VIEW & HEIGHTS, BLOCK CH, LOT 2~ ~--~~__~ P.hD. NO r _~.~..~.%,,.~.~.. .._.~-%. ........... ~ 020-561-59 r~ -Steven R. Pdnnome CLAIRE STEFFENS ;~-. CE 81~9 '~,~- :ERMIT NO. DENISE CIRCLE SITE SECTION ANCHORAGE, AK 99516 ll{?~0~ddo~x?~ Sheet ~'~._~. 4 OF 4 040. 002 Crowther Associates Client: Pannone Engineering Seryices Project: Rabbit Creek View and Heights Block 6H Lot 2A Date: July 24; 20t6 Particle Size Distribution Table Sample Source Block 6H Lot 2A Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 1-1/2 inch 100 h inch 89 ~t 70 #10 62 #40 52 #100 41 #200 37 0.02 mm Classification Silty Sand (SM) 1632 Bellevue Circle/Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: crowther~alaska net TEST HOLE 2 OR ORGANICS 1 2 3:1 7/8/2014 4 7 SOILS LOG - PERCOLATION TEST SLOPE 5 GM SILTY GRAVEL 6 W/ TIVER ROCKS X TH 7 8 9 BOH 10 11 12 13 14 15 16 17 18 DATE PERFORMED: 6/30/2014 WAS GROUND WATER ENCOUNTERED? Y IF YES, AT WHAT DEPTH? SEEP () -4.5' DEPTH TO WATER AFTER MONITORING? -4.1'- DATE: 7/8/14 WEIGHT CALCULATIONS Buoyant Force = Weight of Water Displaced ((Plx(4.83)^2/4)xl2)x62.4 PCF = 13,720 # Up COUNTER WEIGHT Assume water @ -2 ft for Seasonal High Assume angle of repose = 0 Degree Assume bedding does not add to force down Assume tank has no weight Weight of 2' Unsaturated Soil 120 PCF (2'x4.83x12)x120 PCF = 13,910 # Down Weight of 2' of Saturated Native Soil (120 PCF - 62.4 PCF)=57.6 pcf (2'x4.83x12)x57.6 PCF = 6,674 # Down Total Weight on Tank = 20,584 # OK! TH X READING DATE CLOCK TIME NET TIME WATER LEVEL READING NET DROP 1 6/30/14 2:16 --- 3.65 --- 2 2:26 10 MIN 6.82 3.17 3 2:28 --- 3.67 --- 4 2:38 10 MIN 6.81 3.14 s 2:40 --- 3.41 --- 6 1 1 2:50 1 10 MIN 6.51 3.10 PEROLATION RATE 3.2 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 2 FT AND 3 FT COMMENTS: Test hole excavated by the Lot Owner. Prec hole was presoaked. Test run for one hour. Last 3 readings reported PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC' LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE PHONE (907) 272-8218 FAX (907) 272-8211 -�oF A� ��l q l) r �. S j �. � +� A' ..... .%. JJ teven ...... R .. .. ... / R. Pannone CE 8149 s -SAW ,�ITF�'FOp �`��'r 1, ROFESSQO Date 8/14/2014 For Construction Scale NTS P.I.D. NO - 61-39 RABBIT CREEK VIEW & HEIGHTS, BLOCK 6H, LOT 2AS CLAIRE STEFFENS DENISE CIRCLE ANCHORAGE, AK 99516 PERMIT NO. SOILS LOG sheet 3 OF 3 2016 029522 Recording District 301 Anchorage~ 07/22/2016 10:16 AU Page 1 of GRANT OF EASEMENT This easement agreement is made between Claire Steffens, whose address P.O.Box 101847, Anchorage, Alaska (Grantor), owner of the land described as Lot lA, Block 6H, Rabbit Creek View and Rabbit Creek Heights Subdivision, (herein Property) according to the Plat No. 2004-91, records of the Anchorage recording District, Third Judicial District, State of Alaska, for good and valuable consideration, the receipt whereof is hereby acknowledged, and does hereby grant unto Claire Steffens, whose address P.O.Box 101847, Anchorage, Alaska (Grantor), owner of the land described as Lot 2A, Block 6H, Rabbit Creek View and Rabbit Creek Heights' Subdivision, according to the Plat No. 2004-91, records of the Anchorage recording .District, Third Judicial District, State of Alaska, the following grant of easement: described as: , A perpetual, non-exclusive right of way, to provide access by a trail not to exceed ten (10) feet in width for the construction, maintenance, repair, removal and inspection of a water well serving exclusively Lot 2A, Block 6H, Rabbit Creek View and Rabbit Creek Heights Subdivision, Anchorage: and A perpetual right to construct, install, operate, maintain, repair, inspect, use and remove a water well, including all facilities ( eg. casing, pumps, water line and electric line) needed to operate said well, in, under, upon, about, over and through Lot lA, Block 6H, Rabbit Creek View and' Rabbit Creek Heights Subdivision, Anchorage, Alaska,said well to serve only Lot 2A, Block 6H, Rabbit Creek View and Rabbit Creek Subdivision. Said easement more particularly described as: An easement depicted on the attached survey prepared by Lee Karabelnikof, Reg. Land Surveyor No. 3143-S, dated July 21, 2016, having the dimensions as indicated by the line data thereon, an area of approximately 770 square feet. 1. The easement granted hereby shall not in any manner be dedicated for, or subject to, use by the public. The use of this easement shall be exclusive to Lot 2A, Block 6H, Rabbit Creek View and Rabbit Creek Heights Subdivision. Within this easement, rock, soil, sand, gravel, and vegetation may be excavated and removed to construct, improve, maintain and repair the trail area. 2. Grantee may maintain, at Grantee's sole expense, the well access trail descibed with particularity above, for the purpose of effectuating the Grant. Grantor may not place permanent structures over such trail or otherwise make access to the well impracticable. The trail may not exceed 10 feet in width and may be permanently surfaced only with vegetative material. 3. The Easement granted and created is intended to and shall run with the land, with the benefit of the easement appurtenant to the respective dominant parcel and the burden of the easement appurtenant to the servient parcel. This Easement shall be binding upon and inure to the benefit of the parties successors and assigns, heirs, beneficiaries and personal representatives and be perpetual. 4. This Easeme.~t shall be governed by, and construed and enforced in accordance with the laws of the State of Alaska. SIGNED on this the~ I day of July 20'16 GRANTOR: Claire Steffens GRANTEE: Claire S.;I;effens THIRD JUDICIAL DISTRICT ) ss. STATE OF ALASKA ) The foregoin~(~l~l//~ment was acknowledged before me this ?-.t ~T day of July 2016, by ~- i NOTARY i ~ NOTARY ,rOI. lC ,N ANO ,OR THE STATE O, ALASKA THIRD J~J~,~iCT ) SS. STATE OF A~RSR,~' ) The foregoing instrument was acknowledged before me this ~'[ 5q-. day of July 2016, by NOT d ,N AND ,OR THE STATE O, A AS A ~ ('~Oq¢~-~} ~ M~ommJssionExpires' Return t~~. ~0~847, Anchorage, AK 995~0-~847 Page 2 0f 3 2016 - 029522 - 0 ? / / / ,/ ~J SO9'( .ON b ,¢ ,0£ I I II I-- "T" ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MUNICIPALITY OF ANCHORAGE THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this . ~ Dayof /[~te~L*-~ of20/--q, byandbetween(r?,/~ I? e ~te:~tOj herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration ofthe mutual covenants contained herein, the parties to this Maintenance and Repair Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description). 2. Definitions. Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Certificate of On-Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code(hereinafter, "AMC") 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. Permit. An On-Site Wastewater Disposal Permit as required by AMC 15.65 to construct and operate an AWWTS. 3. Term. The term of this Maintenance and Repair Agreement shall begin on the date of approval by the Municipality to operate the installed system or issuance ora COSA, and shall continue ~vhile the AWWTS is in use or is operational or until the property is sold or title is transferred by the owner and a new COSA is issued to the new owner or transferee of the property. 4. Alterations, Installation and Removal of Additional Equipment. Prior to performing any alterations to an AWWTS, the owner agrees to obtain an On-site · Wastewater Disposal Permit fi:om the Municipality in accordance with AMC 15.65. 5. Maintenance and Repairs. A. Throughout the term of this Maintenance and Repair Agreement, the OWner shall maintain their AWWTS in a satisfaCtOry condition capable of producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. The owner shall enter into a service a~reement with an AW~VTS service and maintenance provider approved by the muincipality and the manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it shall be the responsibility of the Owner during the term of tins Maintenance and Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay for any and ali: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws, regulations, roles and orders for the AWWTS. C. Upon request by the Municipality, the owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor, the owner agrees to allow the Municipality access to tins information. D. Owner acknowledges that the frae for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. F. Owner age_es to gran~ the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. H. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Murficipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. I. Owner agrees to provide and maintain a telephone connection to the AWWTS as required by the AWWTS approval. 6. Nonwalver. The failure of either party at any time to enfome a provision of th/s Maintenance and Repair Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Maintenance and Repair Agreement or any part hereof, or the right of such party thereafter to ~nforce each and every provision hereof. 7, Amendment. A. This Maintenance and Repair Agreement shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality that this Maintenance and Repair Agreement was executed with, and such writing shall be attached to this Maintenance and Repair Agreement as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this agreement, the only authorized representatives of the parties are: b. Municipality: Director, Community Development or designated authority C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 8. Jurisdiction: Choice of Law. Any civil action arising fi:om this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anch6mge. The laws of the State of Alaska shall govern the rights and obligatinns of the parties under this Mainte~}ance and Repair Agreement. 9. Severabilit¥. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Maintenance and Repair Agreement. O~R ~ _-..4 ,/3/ By: ~------~'-'~ ~~--4:::~ (siguature) (print name) STATE OF ALASKA THIRD JUDICIAL DISTRICT The foreg~ 20 I,r, ~( 'x My. MUBIICIPALITY: ) tg instrument was acknowledged before me this ~0 day of ~J/~., .,- ~ ............. ~Z ~.. ' ',,,,,5~ [~,~,,' (signature) Date: (prim name) Title: Register 163, July 2002 ENVIRONMENTAL CONSERVATION Co* l TABLE B. ABSORPTION FIELD AREA REQUIREMENTS FOR UNIFIED SOIL CLASSIFICATION Minimum inf'dtrative area,* Unified Class Description measured in square feet per bedroom GW* Well-graded gravels 85 GP* Poorly-graded gravels 115 SW Well-graded sands 125 SP Poorly-graded sands 150 GM** Silty gravels 225 SM** Silty sands 275 *GW and GP soils are unsuitable for use in absorption areas unless a two-foot thick layer of sand, meeting the requirements of 18 AAC 72.260(a)(4)(D), Table C, Noie 1, is placed between the distribution rock and the receiving soil; the department will waive this requirement if a waiver does not threaten public health, public and private water systems, or the environment, and in accordance with 18 AAC 72.060. ** Use of these soils in absorption areas require a percolation test by a registered engineer, conducted in accordance with 18 AAC 72.265(9). (7) the system complies with the separation distances set out in 18 AAC 72.020; (8) the ground surface slope is less than 25 percent for trenches, and less than five percent for beds; (9) as shown in Figure 1 of this subsection, at least 50 feet separates any part of the soil absorption system from any slope greater than 25 percent, whether man-made or natural, with a drop in the shrface height greater than 10 feet; and 12