Loading...
HomeMy WebLinkAboutAUDUBON HILLS #1 BLK 1 LT 10AAudubon Hills Block Lot IOA #015-235-08 Permit Number: Tax Code Number: Work Type: Permit Effective Dates: Design Engineer: Subdivision: Site Legal Address: Owner/Add ress: On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 OSP161016 01523508000 WellSeptic Initial Februaw 18,2016 to February 17, 2017 PANNONE ENGINEERING SERVICE AUDUBON HILLS #1 AUDUBON HILLS#1 BLK 1 LT 10A G:2739 LAMPMAN CAM 7200 HUFFMAN RD ANCHORAGE AK 995162453 Site Mailing Address: 6693 DOWNEY FINCH DR, Anchorage Lot Size in Sq Ft: Total Bedrooms: 53602 5 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Pdvate Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ///~ ~ MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 9(}7~-343-7904 Fax: 907-343-7997 ON-SITE SEWER/VVELL PERMIT APPLICATION Parcel I.D. 015-235~08 . Property owner(s) Cam Lampman Mailing address 7200 Huffman Road, Anchorage, AK 99516 Day phone Site address NSN Downey Finch Drive Legal description (Sub'd., Block & Lot) Audubon Hills #1, Block 1, Lot 10A Legal description (Township, Range & Section) Lot Size 53,602 _Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: ([~ all that apply) Absorption Field [] Initial [] Septic Tank [] Upgrade [] Holding Tank [] Renewal [] Privy [] Private Well [] Water Storage [] TYPE OF DWELLING: Single Family (SF) (w/we ADU) Duplex- (D) Multiple Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or autherized agent) Permit/Rush Fees: Date Of Payment: Receipt Number: Permit No. (~_O Waiver Fees: Date of Payment: Receipt Number; Waiver No. Permit App_£- :-: '.Jr. ~' Pannone Engineering ServiceS LLC Steven R. Pannone;l~rincipal Registered Professional Engineer E-maih steve(~panenAak.com ' February'2, 2016 Subject: Audubon Hills #1, Block 1, Lot 10A Well and Septic System Permit Request Design Narrative This is a design narrative for a permit to install a well and septic system to be issued for this property. The proposed systems will serve an proposed five bedroom (5) bedroom house. Currently tee lot is undeveloped. The surrounding developed lots are served by private wells. There are no wells within 100' of the proposed septic system. Soils. Two test holes were performed on this lot' b~]~ES ~n'November of 2015, and groundwater was monitored for at least seven days, Ground water was observed at a depth of 3.0' below the surface in the tes~ hole monitor tube in November of 2014. Bedrock was not encountered in the test hole, Based on the results of the percolation tests and overall so]l~ aPpearance; an application rate of 2 gallons/day/square feet was used for a CAT III wastewater system in the'area of the test hole. 2. Soil Absorption System Design. a. See Sheet I of the design packag~i 3. Surface Water: There is a mapped "unclassified drainageway" approximately 60' from the drain field, but no surface water has been observed in the feature at the time of the test hole. There is ~o surface water within 100' of the proposed septic system. 4. Topography: The existing topography generally slopes from the east to the west in the area surrounding the septic system at approximately 12%, There are no steep slopes within 50' of the proposed drain field. The proposed drain field will rn~Jntain 50' separation all steep slopes. 5..Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued, The proposed installation will not ~ffect the future development of th is or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-malE steve@panerrRak corn February 4, 2016 Subject: Audubon Hills #1, Block 1, Lot iOA Water Monitoring Ground water in Test Holes 1 and 2 on Audubon Hills #1, Block 1, Lot 10Awas monitored at 3 feet in the month of November in 2015. The fall of 2015 was extremely wet, with the wettest period during the month of November rather than October. It is my opinion that high ground water monitored during the month of November on the subject lot is acceptable and as accurate as possible. Additionally the original test holes performed for the subdivision of this lot (attached) show ground water no shallower than 11.0 feet in 2005. The soils log from Lot 8 just to the east of this system found water at 10.0 feet in the month of May. Based on all information available using 3 feet as high ground water will not impact the 2 feet of unsaturated material required by the MoA beneath the drain rock of a wide trench drain field. The proposed installation will not affect the health or safety of this lot or the surrounding lots.' If you have any questions or concerns, plea_se contact me at 272-8218. Sincerely, .......... Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-82tl CO- I ~ "UNC~SSIFIED DRAINAGEWAY' X NO EVIDENCE OF SURFACE WATER / " - / k. ~%AT TIME OF TEST HOLE ' / / '--~7--" O' UT LITY EASEMENT / ~¥ / ' WELL (*) ~ / / / % I ~ . / V / _. WITH (2LA) AX20 PODS ~?'- i ~ ~ ~ ,~/ (' ~ / / AND AUX, PUMP VAULT / / ~_ ¢~_~/k~-,..~ I '~¢~/ / ' BED 25LF x 15'W x 0.5'ED x +270 l/ /{ / ~ REMOVE ORGANICS AND PLACE ~ ./ ~; ,/ ' ..... / . ~:,~~~ , .': : ,,: I:-- / / / /,/ ~ ~:' ~ /% / ~ ' ,. i :'~ ~ - ~ , / NOTES: P~O~ ~G ~C, ~C ~ OF ~L~ 8/19/16 PHONE (907) 272-8218 FAX (907) 272-8211 · · f'=5o' AUDUBON HILLS ~1, BLOCK 1, LOT 10A ~ 315-235-o8 SPINELL HOMES I~.. CE ~149 .'~ PERMIT NO PLAN ANCHORAGE, AK 99516 t~(?~0~SN~. Sheet 20' ~ /-RISER ~.~EPOSE //POD WEIGHT CALCULATIONS Buoyant Force = Weight of Water Displaced (((PIx(5.5)^2/4)xlYi+17.6)x62.4 PCF = 24,797 # Up ~ ~ ~ ~PE I]: 641 ..3CF COUNTER WEIGHT Assume water ~ surface - all soil soturoted 4.0 ~2~~ -RrSER 12.56CF ~ ~, "~,' ~A' '/ Assume angle of repose = 20 Degree (WORSE CASE) 56.25C~ (X2) Assume bedding does not add [o force down ~ ~ ~ED TANK W/ Weight of MoA Type II (135 PCF 62.4 PCF)=72.6 pcf ~} ~ SEWER CK R0 Total Weigh( on Tank = 12,682 ~ OKi ~ ~2' TYP. ~ 2500 ABV~NTEX TANK BUOYANCY CALCULATIONS ~ ~ 2 ~ -- X ~DRArN o~/ SECTION ABBREVIATIONS DESIGN PARAMETERS TH TEST HOLE PRIMARY SEPTIC SYSTEM NO. BEDROOM: 5 {750 9pd) LEGEND EA EACH FCO FOUNDATION CLEAN OUT TANK S~ZE: 25009 ADVANTEX ~ W- WATER LINE/ T~ TANK CLEAN OUT NO. W/ (2LA) AX20 PODS WELL RADIUS PERC RATE: 50-60 MPI C~ CLEAN OUT NO. SOiL RATING: 2 GPD/SF SS ~ NEW SEPTIC MC MONITOR TUBE NO. AREA ROD: 575 SF R.I. RIGID INSULATION SYS. TYPE: 8ED 15'W DCO DOUBLE CLEAN OUT MIN LENGTH: 25 LF DV DIVERTER VALVE FS FLOW SPLITTER USE: (E) 'EXIST[NO 25.0LFxlS'WxO.5' E.B., +2.0' TO (P) PROPOSED WITH 5' OF SAND TYP WPICAL TOTAL AREA: 575 SF PHONE (907) 272-8218 FAX (907) 272-8211~:~i~ Sco,e SPINELL HOMESra'~l~".l CE 8149 ...~ =ERMIT NO. DOWNEY FINCH DR~VE DESIGN DETAILS ANCHORAGE, AK 99516'~(, ~0~9~%~ Shee( SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.5.5. 2. SCOPE OF WORK: INSTALL NEW 2bOOg ADVANTEX TANK WITH 2EA AX20 PODS, AND SOIL ABSORPTION SYSTEM. INSTALL WELL 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 3 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 5 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY· 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION' AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. B. THE CONTRACTOR IS RESPONSIBLE FOR ALL R,O,W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES· 7. THE CONTRACTOR SHALL PROVIDE 2¢ HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN· 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-GUILT DRAWINGS TO THE ENGINEER· THE RED LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS· 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11 THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED· THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY TIlE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR· 12, THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS-PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL dHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED· CONTRACTOR: BY: TITLE: DATE: NOTES: PANNONE ENG SVC, LLC FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ~'.~.~. ...... PHONE (907) 272-8218 FAX (90V) 272-82,1 ~' ¢,~ ~'. CE $149 .'~, DOWNEY FINCH DRIVE DESIGN DETAILS ANCHORAGE, AK 99516 Sheet SOILS LOG - PERCOLATION TEST TEST HOLE 1 SLOPE / s TE PLAN / L~J OR / / / 10 -- ,'/ . WAS GROUND WATER SLOPE 14 ~ ENCOUNTERED? Y 15 ~ IFYES, ATWHAT TH DEPTH? -3J X 17 ~ DEPTH TO WATER AFTER MONITORING? -3'- 18 DATE: 11/10/15 CLOCK READING BATE NET TIME LEVEL NET DROP DATE PERFORMED: 11/03/15 TIME READING ~ 5/22/15 11:00 --- 8.15 --- 2 11:30 30 MIN 8.84 0.69 3 11:30 --- 8115 --- 4 12:00 30 MIN 8.75 0.60 5 12:00 ~ --- 8.15 --- 6 12:30 ~ 30 MIN 8.74 0.59 SOIL TEST RESULTS/ANALYSIS * PERCOLATION RATE 50.8 (rain, rich) . PERC HOLE DIAMETER 6" * TEST RUN BE~EEN 4 FT AND 5 FT. ~ TEST RUN FOR OVER AN HOUR. LAST THREE READINGS PROVIDED. COMMENTS: Test hole excavated by POMRANING EXCAVATING. Test Hole was presoaked before Perctest. PERFORMED BY: Joseph Lawendowski. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINE5 IN EFFE~ ON THE DATE OF THIS TEST. FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, AK 99510 .. PHONE (907) 272-g21B F~X (~07) 272-8211 ~... ~:.~ P.ID. NO AUDUBON HILLS ~1, BLOCK 1, LOT 10A SPINELL HOMES SOILS LOG ANCHORAGE, AK 99516 lli~?~b~i~s{~ Sh~t CLOCK WATER READING BATE TIME NET TIME LEVEL NET DROP READING 1 5/22/15 11:00 ... 8.15 ... 2 11:30 30 MIN 8.84 0.69 3 11:30 --- 8115 --- 4 12:00 30 MIN 8.75 0.60 5 12:00 ___ 8.15 ___ 6 12:30 30 MIN 8.74 0.59 SOILS LOG - PERCOLATION TEST TEST HOLE 2 SLOPE 2 SW SILTY SAND -- ML AND SILT TH-2 WAS GROUND WATER SLOPE 14 ENCOUNTERED? ~ IF YES, AT WH~T TH DEPTH? -3-' X DEPTH TO WATER AFTER MONITORING? -3'- CLOCK WATER READING DATE NET TIME LEaL NET DROP DATE PERFORMED: 11103115 TIME READING 2 12:15 30 MIN 7.29 1.02 4 12:45 30 MIN 7.27 1.00 s 12:45 j --- 6.27 -- 6 1:15 ] 30MIN 7.26 0,99 SOIL TEST RESULTS/ANALYSIS · PERCOLATION RATE 30,3 (min/inch) · PERC HOLE DIAMETER 6" · TEST RUN BE~EEN ].5 FT AND 2,5 FT. · TEST RUN FOR OVER AN HOUR, LAST THREE READINGS PROVIDED. COMMENTS: Test hole excavated by POMRANING EXCAVATING. Test Hole was presoaked before Perc test. PERFORMED BY: Joseph Lawendowski, I CERTIFY THAT THIS TEST W~ PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. PHONE (907) 272-8218 F~X (gO7) 272-g~H ~.'~--- ~--~ SPINELL HOMES PER~ SOILS LOC ANCHGRAGE, AK 99516 5OF5 CLOCK WATER READING DATE NET TIME LEVEL NET DROP TIME READING I 5/22/15 11:45 ... 6,27 ___ 2 12:15 30 MIN 7.29 1.02 3 12:15 ___ 6.27 .- 4 12:45 30 MIN 7.27 1.00 s 12:45 ... 6.27 -. 6 1:15 30 MIN 7.26 0,99 g910 0 • 4;° \' A G"p i Municipality of Anchora =- ��°Q, On-Site Water and Wastewater Progra N (907) 343-7904 •.I '4010- f 1 s F E T Y a- N Certificate of On-Site Systems App << OL68L � Parcel I.D. 015-235-08 Expiration Date: 'RCL�.A\ 03, 01c,1 1. GENERAL INFORMATION: Complete legal description AUDUBON HILLS#1; BLOCK 1, LOT 10A Location (site address) 6693 Downey Finch Drive*Anchorage,AK 99516 Current Property owner(s) Anthony Rivas Day phone Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: __ — Date:/O4/ ,3/1# COSA to be rele- ed to the enginss otherwise requested by the engineer. COSA Fee $ 52.f Waiver Fee $ Date of Payment 1 11210111 Date of Payment Receipt Number (131Q5Cq Receipt Number COSA# 85Ci?110t-1 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that The on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: 1( 1 ZOOS 0000��\ In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system o4 OF I /�N in accordance with the guidelines and regulations established by the Municipality of Anchorage and o �..• ` �/' ).'i--‘1()1) 0n� industry practices. The reported results describe the condition of the system/s on the date/s of the Qom V. .•' II •7 U 1) evaluation. Separation distances were measured to readily identifiable features. Hidden defects or Q ' ' • - encroachments may exist that were not identified during the evaluation. The operational life of all wells / '6" .• 4 4., T� 1� �� VA and septic systems depend upon a variety of variables, including but not limited to, soil conditions, VA groundwater levels (that may fluctuate during the year), quality of construction (materials and 4 vA workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and / are outside the control of GEG. Satisfactory test results do not guarantee future performance of the / '• -4 :•, • Corn ss. system/s; therefore, GEG makes no warranty(express or implied) regarding the future performance of 170 9 •• . CE-795 QQ the well or septic system. GEG makes no representation whether an alternative well or septic system 04's` .• I1 l2b c '`O, can be installed on the property in the event either of the current systems fail to perform adequately in 4 P, . • ... . co the future. The content of this report is for the sole benefit of the person/party that retained GEG to ��Papro f e s s oIN o\F' perform the evaluation. Reliance upon the information provided in this report by any other person or ��p�.Opoo party (including subsequent property purchasers) is not authorized, nor will it confer any legal l h whatsoever. f'`�-ltd ��f '�VVt, �v� �C. #AECC884 6. DSD SIGNATURE g ON-SITE '? WATER AND I System #1 Approved for 5 bedrooms 5 WASTEWATER O System #2 Approved for bedrooms ;‘ PROGRAM S� Disapproved ��9'��/T \I1�Gcc� Conditional approval for bedrooms, with the following stipulations: By: I Original Certificate Date: .i c 0 3/ a 01 i( The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. --.•1 7. ATTACHMENTS: COSA Checklist X Nitrate Advisor• ;, C', ,_.. • Septic System Advisory Arsenic Advisory . , Well Flow Advisory Other COSA blue sheet 10-10.12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: AUDUBON HILLS#1; BLOCK 1, LOT 10A Parcel ID: 015-235-08 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 4/2/16 Sanitary seal (YIN) YES Wires properly protected (Y/N) YES Total depth 160 ft. Cased to 84 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 4/2/16 11/8/18 Static water level 30 ft. 30.1 ft. Well production 6 g.p.m. 4 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 ml. Nitrate ND mg./L. Collected by: GEG, Ltd. Arsenic: <5.0 ug./L. Date of sample: 11/8/18 B. SEPTIC/HOLDING TANK DATA Tank Type/Material ADVANTEX/STEEL Date installed 8/23/16 Tank size 2500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout(Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping - Pumper SEE ATTACHED MAINTENANCE REPORT C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE AT MONITORING TUBE Date installed 8/23/16 Soil rating ( .p.d./ft r ftZ/bdrm) 2.0 System type BED/Mo u"ii)/ Length 25 ft. Width 15 ft. Gravel below pipe 0.5 ft. Total depth *3.4+ ft. Eff. absorption area 375 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 11/8/18 Results(Pass/Fail) PASS For 5 bedrooms Fluid depth in absorption field before test 0 in. Water added 967 gal. New depth 0 in. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 750+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) NO If yes, give date - CA "SEE ATTCHED MAINTENANCE REPORT D. LIFT STATION "ELECTRICAL INCE ECTION COMrLCTCO BY-totOA Date installed 8/23/16 Size in gallons 250 Manhole/Access (Y/N) YES "Pump on" level at in. "Pump off' level at • in. High water alarm level at in. Datum • Cycles tested • Meets alarm &circuit requirements? * * E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 50'+ On adjacent lots 100'+ Absorption field on lot 50'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank75'+ )4e.--r CSE "r -�`ne- v` t..1 s-i-Na-u. Animal containment areas '" Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 50'+ Wells on adjacent lots 50'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 50'+ Driveway, parking/vehicle storage 10'4- Curtain 0'+Curtain drain *10'+ Wells on adjacent lots 50'+ F. COMMENTS *PER 11/1/16 MOA INSPECTION REPORT"T12N R3W; SECTION 23, PARCEL 12 HAS A FENCED AREA WITH A BARN LOCATED IN THE EASTFRN PORTION ALTOUGH THE BARN IS 100'AWAY THE FENCED AREA THAT SPANS MOST OF THF LOT MAY BRIFFLY HARBOR HORSES ON ANY GIVFN DAY APPROXIMATI FY 25'TO CI OSFST POINT OF FFNCE .looms• 11 ♦ ` /� G. ENGINEER'S CERTIFICATION ••�P�.`,. �. . ��. • I certify that I have determined through field inspections and ' 4•�i ist *•�• review of Municipal records that the above systems are in • • conformance with MOA COSA guidelines in effect on this • date. • �:.. i-f 'ey •. Gam-.s;Lk//= Engineer's Printed Name JEFFREY A.GARNESS O.%5 /. CE— ° . ��&a Date ) i e ••1;Fp PROFES 1�' --••• ` LICENSE ,'\ FESS * #AECC884 r��%%w� (Rev. 10/12/12) 09/11/2018 15:55 8686770 APLUS PAGE 02 - -- -- -'- —. (fAX907 277 3715 r.1J10t/Loy08/2812018 11:42 Anchorage Tank 3'3 383 F N ■■ ■U111M■■ ■ III. I 1 ■■ ■ I 111 I II 1 1 i - mi ■ o I 1111101• ■ Of • I f■■ Ill S' A 1. .?--mvairilimex6 Field Maintenance Report AnchorageTank Annual Inspection907-272-3543 ngorF:L, a.,�e„aM,«n syw• Larry Betts Anthony Rivas - comms Mono eaadrtss 07)556.555 6693 Downey Finch Drive,Anchorage AK 99516 (9 (9c 7) Po AX Sao In g Couinr r.7 d!! RN dPJL N Del��/05/2017 of Loo.flopcooko ' AX 140034 05P161016 424432 423881 R7U132106 _, Retrieve O&M Into Measure Sludge/Scum Day flow. Sludge --- 1st Compartment — �Cvrr4nJ,rl` ous Current Previous Rer.irrsrtic, -, �� 7ryngratltngc: 2nd Compartment Current Previous Current Pr.roua l Inspect/Clean AdvenTax Filter Map4tt Clean Odor. /Normal LI Pungent Laterais/Oriloos/" XI Perform Field SaritPin9/AltsaJrxatians Biomat- /Normal L Excessive Pod Bottom /f nay 05 s Wilk) pH i6-9) OO(2-51 Bridgiriq/Pending'x Nene/Minor L Exceeeria intake Vent / J/J 113,1 6 3 _ Inspect/Clean Discharge Ptanp System Inspect inspect clean Odor of Sample Riser/14 ;/ Roars 7 / IcaS /i Muaty ,Earthy ��Moldy YP — Split-A.BoxoxPump Nonrtyplcal Sui?Ce D Cabbage E Decay Float cords ' Oily like in l :Yes /No Inspect/Service Other System Components Poser In lank L Yes NO Inspect CleGn hsp2et Clean Cheek Control Panel Disdn:ecticn Equipment ?' dispersal t..terabJOtilirarr Jer RcIrcc //6/_Amps Discharge Ames Observations i 1 tI Additional Services Rendered - — 9. TJ Cleaned textile sheets? Repleeed UV Items? Audible sod visual Awns I�dK 7 R�ao�sad other'Rams? Dial bone(telemetry only) it!Yes No Parts Used:W=Warranty.B=Bitable;d appropriate selection) inspect/Diem Pump System w a Item Number Cenetlotlan Inspect Clean - Rlser/Ud a Splice Bcx Mat Cords Y �— Floats 7Final/Safety Inspection • Pump J �. {7f 7I,]'RSV rahr�d ds beted On HiotvbP."'eller � ,Maniteld reconnected;flush valves dosed Blotubo Pump Vault StIllinterg/R900mme tdatlonS / control panni feaetivrod RecirCrialtna Splitter ware.. ii71 L]System performing:no IurtMr action needod L.Tana needs pumping Cre ter novice • Others Comments--------- — .•�"' Date_Jr_ Signature Fax Completed form to 1-868-384-7404 • SG$ SGS Ref.# 1186402001 Client Name Garness Engineering Group,Ltd Printed Date/Time 11/21/2018 11:35 Project Name/# Audubon Hills#I,B I,LI0 A Collected Date/Time 11/08/2018 11:00 Client Sample ID Audubon Hills#1,B1,L 1 A Received Date/Time 11/08/2018 16:17 Matrix Drinking Water Technical Director Stephen C.Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Total Dissolved Solids 166 10.0 mg/L SM21 2540C A (<500) 11/09/18 EWW Metals by ICP/MS Hardness as CaCO3 ND 5.00 mg/L SM2I 2340B D 11/09/18 11/12/18 DSH Waters Department Total Nitrate/Nitrite-N ND 0.100 mg/L SM21 4500NO3-F C (<10) 11/14/18 DMM Microbiology Laboratory E.Coli Negative 1 100mL SM21 9223B B 11/08/18 A.L Total Coliform Negative 1 100mL SM21 9223B B 11/08/18 A.L Private Individual Analysis Chloride 18.5 0.200 mg/L EPA 300.0 A (<250) 11/19/18 11/19/18 DMM Conductivity 288 1.00 umhos/cm SM21 2510B A 11/13/18 DMM Fluoride ND 0.200 mg/L EPA 300.0 A (<2) 11/19/18 11/19/18 DMM Sulfate 18.1 0.200 mg/L EPA 300.0 A (<250) 11/19/18 11/19/18 DMM Alkalinity 90.0 10.0 mg/L SM21 2320B A 11/13/18 DMM Aluminum ND 20.0 ug/L EP200.8 D 11/09/18 11/12/18 DSH Antimony ND 1.00 ug/L EP200.8 D (<6) 11/09/18 11/12/18 DSH Arsenic ND 5.00 ug/L EP200.8 D (<10) 11/09/18 11/12/18 DSH Barium ND 3.00 ug/L EP200.8 D (<2000) 11/09/18 11/12/18 DSH Cadmium ND 0.500 ug/L EP200.8 D (<5) 11/09/18 11/12/18 DSH Calcium ND 500 ug/L EP200.8 D 11/09/18 11/12/18 DSH Chromium ND 2.00 ug/L EP200.8 D (<100) 11/09/18 11/12/18 DSH Sonja Blewett From: Sonja Blewett Sent: Thursday, November 29, 2018 11:34 AM To: 'Leif Herrington' Cc: DAVID J. PARKS Subject: Comments from the MOA on Audubon Hills#1 B1 L10 (6693 Downey Finch) Attachments: doc04614420181129113040.pdf Hello, please see attached comment#2 from the MOA.There is an open residential permit for this property to finish the unfinished basement that all parties need to be informed of.Thank you! Sincerely, Sonja Blewett Corporate Secretary/Treasurer Garness Engineering Group, Ltd. 3701 E.Tudor Road,Suite 101 Anchorage,Alaska 99507 Phone: (907) 337-6179 Fax: (907)338-3246 Mobile: (907) 748-6179 Website:www.garnessengineering.com Original Message From:Scan<Scan@garnessengineering.com> Sent:Thursday, November 29,2018 11:31 AM To:Sonja Blewett<Sonja@garnessengineering.com> Subject: Garness Scans DO NOT REPLY TO ADDRESS 1 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the"AGREEMENT" made and entered into as of this 2/41t" Day of i\U ri`YIbei7 of 20 ' , by and between 4itiM knt° , herein the"OWNER,"and the Municipality of Anchorage,herein the"MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as G L dl 3 ]�olut(P 3 ,,c L I,z A..,,/....y.„ ? ? TI , located at(legal description) Atk L In` ;1\S - 1 LibA -t 1 2. Maintenance,Repairs and Alterations. T(Owner is required to read, understand and initial each section) :1'1-67 Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in 4 accordance with the equipment's approval for operation in the Municipality. GIt shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee(typically $400 to $600). A Owner agrees that only maintenance and personnel repair a roved p pp by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces theotentia p ! failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 i(9 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. t, Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. --/ft2 Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. d Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. 14; Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing j() guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof,or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev.05/18/2018) Page 2 of 3 Off: (signature) Date: OD ' v. — cC)\ zevi � r �,c.c_ (print name) STATE OF ALASKA ) )ss. THIRD JUDICIAL DISTRICT ) The foregoingc rume acknowledged before me thisay of N��'niib(�V 201.,by , QWi 4 a 9 ```�t� r���� 0WIALVO4 'ter NOTARY PUBLIC FOR ALA • wedge My Commission expires: ~ • � A 1 • MUNICIPALITY: QQUt5Q9By: JUt & (signature) Date: 111 a 8118 R-00e.c c l n.r r o H (print name) Title: (rev. 05/18/2018) Page 3 of 3 • 4 " •