Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 7H LT 29ARabbit Creek View & Heights Block 7H Lot 2S)A #020-571-30 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP161247 02057130000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: September 16, 2016 to September 16, 2017 Design Engineer: C&M ENGINEERING SERVICES Subdivision: RABBIT CREEK VIEW & HEIGHTS Site Legal Address: RABBIT CREEKV]EW & HEIGHTS BLK 7H LT 29A G:3340 Owner/Address: ALBRECT JOHN 1515 OTTER STREET ANCHORAGE AK 995040000 Site Mailing Address: Lot Size in Sq Ft: 26239 Total Bedrooms: 2 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private WelI N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at Ieast 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: A complete soils test is to be completed for the alternate field prior to construction. Construction may proceed at your own risk prior to 7 day ground water monitoring. Received By: Date: ¢ Issued By: ~//// /,~E~/r~"...-~.~-- Date: ~/6/'~/' Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 e (907) 343-7904 · Fax (907) 343-7997 http:llwww.muni.orqlOnsite Development Services Division On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** Waive~: OSV16111'1. COSA#:__ Permit#: OSP16'1247 PID#: 020-571-30 Legal Description: Rabbit Creek View & Heiqhts B7H L29A Engineer: C&M En.qineerin.q Services Applicant: John Albrecht Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 40.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. [] The affected adjacent propei~y owner(s) have been given a 7 day notice regarding this waiver. [] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. [] Adjacent properties are not affected by this ;vaiver. Waiver is Granted: X Waiver is not Granted: Date: q/~/'~'" Approved by: ~ ~Y~ffd~f~.~._~ Name of Reviev~r"- **** VARIANCE/WAIVER REVIEW **** UN]CIPAL]TY'OF ANCHORAGE Community Development Department Phc Development Services Division On-Site Water & Wastewater Program ON-SITE SEWERNVELL PERMIT APPLICATION Par0e i.D. %o Property owner(s) ',~/L/' ,/~. 'i~i'~ Y' Mailing address i.~il',~½ e'--p~. ~ Site address Dayphone .-~? ~ '~ 7 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size i/~t,~¢~¢j Sq. Ft. Number of Bedrooms APPLICATION IS FOR: ([~] ali that apply) Absorption Field Septic Tank HoMing Tank ' Privy [] Private Well '~' Water Storage [] APPLICATION IS AN: Initial Upgrade Renewal TYPE OF DWELLING: Single Family (SF) (~wo ADU) Duplex (D). Multipie Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: pate'of Payment, Receipt Number: Waiver No. Permit App_g-1-12.doc C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Proposed Septic System for RABBIT CREEK VIEW AND HEIGHTS BLOCK 7H LOT 29A Dear Reviewer, The above referenced property is currently vacant and the owner plans to develop the lot and construct a new 2 bedroom home served by onsite water and wastewater utilities. We are requesting approval to install a well, septic tank, and leachfield. We are proposing to install a new 1000 gallon tank, and a new 2 bedroom shallow trench system. Replacement leachfield sites are also shown. The soils are silty sand material with some clay. A sand~'~g~l approximately 2' thick overlays the silty soils. The organics have been stripped from the lot at the test hole and leachfield location. The silty soils could be considered marginal for septic system installation, however the system will be installed high in the soil column to maximize use of the good soils. The system is sized for 2 bedrooms and is oversized. A sand liner will be installed to provide some filtration prior to effluent reaching and plugging the sitly soil. Surveyed contours indicate a steep slope approximately 40' down slope from the lower leachfield trench. We are requesting that the separation distance from the leachfield to the steep slope be waived from the required 50' to 40' minimum. A cross section included with this submittal details the slopes, and how fill will be placed. Included with this letter is a permit application and design package, including plans, specifications, calculations, and soils logs. The installation of the proposed septic system will not adversely impact adjacent lots, which are currently undeveloped. Changes to drainage patterns are not anticipated. Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cqbalzariniC, qmail.com with any questions or concerns. Sincerely, Charles Balzarini, PE RABBIT CREEK BLOCK 2REEK ~EW AND HEIGHTS 7H LOT 30A (UNDEVELOPED)  BALZARIN/ ~ 3854 .' ~ ~ BLOCK 1OH LOT 2A ~,~¢~,~,. ~ ~ (UNDEVELOPED) S~'~ :~ 0 BLOCN 1OH LOT 3A SEE ~ INTERFERE W/PROPOSED PROdECT) ~E,~S w/~ ~ ~ ~ ~ rlo00 GAL i PROPOSED PROPOSE DRIVEWAY 2 BR PER PLOT PLAN HOME I REEK VIEW ANO HEIGHTS BLOCK 7H LOT 29A I PAINE R~AOAD o CLEANOUT · MONITOR TUBE [] TEST HOLE 0.5~ \ SLOPE INDICATOR CLOUD 9 LOT 2 / NOTES; 1. 3HE PROPOSED SEP~C SYSTEM IS GREATER 3HAH: 100' FROM ANY PRIVATE WELLS 200' FROM ANY PUBEC WELLS 100' FROM ANY SURFACE WATER 50' FROM ANY STEEP SLOPES 10' TO ANY PROPERTY UNE OR FOUNDA310N 5' TO ANY TEST HOLES SCALE: 1' = 40' LEGAL DESCRIPTION: RABBIT CREEK VIEW AND HEIGHTS BLOCK 7H LOT 29A CAM ENGINEERING SERVICES OWNER: JOHN ALBRECHT IDATE:B/25/161REV:O IDRAWN: CBIREF: 907- 854- 5558 SITE PLAN NoIm03s Bcjgg-'l,~B-/..06 :_43~ ]BO :NMV~tO J O :A3a ] gt/cJ~/B ::mmva J J. HO3~ImV NHOP :ht3NMO $301A~3S ONI~I33NION3 I/4~0 ¥6~ J.09 H/. )t0098 SJ. FIOI3H aNY M31A )t33~t0 J. IBBYU :NOLLdI~O$30 9V03'1 C&M ENGINEERING SERVICES 907-854-5558 Septic Desi§n Calculations Residence: Rabbit Creek View & Heights Block 7H I RESIDENCE/LOT INFO number of bedrooms 2 br Water usage/bedroom 150 gpd/br Water Usage 300 gpd Percolation Rate 60 min/incb Groundwater Depth 11 ft bgs Test Hole Depth 14 ft bgs from original grade from original grade DRAINFIELD system type: Conventional type: Shallow Trench Application Rate 0.45 gpd/sqft required absorption area 666.666667 sqft trench width (W) 5 ft gravel depth (D) 3 ft ShallowTrench Factor 0.58333333 Min Required Length: 78 ft Total Excavation Depth: See cross section Filter Sand Depth 2 ft Cover: 3 ft min Insulation: 2" blueboard Use Length: 80 ft Effluent Pipe: 4" ASTM 3034 below distribution pipe (Shallow trench factor * Required absorption area/W) Design Summary System type: ConventionaJ Tank: :1000 gal New Drainfield: 5'Xa0'X3' W'xL'xD' shallowtrench Total absorption area: 686 sqft See cross section prior to excavating Calc By: CGB Date: 8/25/20:16 C&M ENGINEERING SERVICES Ph: 907-854-5558 SPECIFICATIONS FOR ONSITE SEPTIC SYSTEM - MOA CERTIFIED INSTALLER LEGAL: Rabbit Creek View and Heights Block 7H Lot 29A September, 2016 A. GENERAL 1. The septic design is for a 2 bedroom, single family residence only. 2. The site plan and drawings shall be a pad of this specification. The Wastewater system shall be installed by a certified installer in accordance with moa requirements. All materials and workmanship shall meet the Municipality of Anchorage's, and the State Department of Environmental Conservation requirements. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. The engineer shall pedorm percolation tests and groundwater monitoring prior to finalizing design. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environment of Conservation requirements. It is the responsibility of the owner to obtain all necessary permits or easements. A licensed surveyor should locate all nearby lot lines, easements, exact 100' radius from the existing and neighboring on-site wells, and any nearby surface water. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed, after construction of the drainfield. 9. The contractor shall provide the engineer with adequate notice to perform inspections. 10. Insulate the sewer line if it passes under the driveway or parking area, with a minimum of 2" extruded board insulation, rated for burial, and on the moa approved list. SEPTIC TANK 1. Septic tank shall be a fiberglass or steel, lO00-gallon capacity tank of MOA approved construction. Installed to meet MOA requirements. 2. Install a foundation cleanout within 5' of the foundation. A combination of soil and 2" minimum of insulation shall be placed over the tank, to prevent ponding and promote drainage. The insulation shall be rated for burial and meet moa requirements. C. DRAINFIELD 1. The Drainfield is to be located as shown on the site plan. Notify Engineer of any changed site conditions. The total depth of the initial drainfield excavation is to be at maximum 8' deep from original grade. Note that 1-2' of material has been removed in some places. Leach field Shall be installed as shown on cross section. Bottom of excavation shall be level +/- 1.5" max. If bedrock or inconsistent soils are encountered, notify the engineer immediately. The bottom of the excavation shall be filled with 2' of moa approved filter sand. In the event of over-excavation, a moa filter sand shall be used to maintain the 6' separation distance from the bottom of each trench to the bottom of the test hole(s).The top of the sand layer shall be level, plus or minus 1.5", and raked, prior to placing sewer rock. Care shall be taken to not compact the sand. A 3 foot effective layer of sewer rock is to be placed in the each trench. The effluent piping is to be set on top of this layer, buried with sewer rock, with 2" of sewer rock cover over the piping. 5. The Distribution pipe shall be 4" sch. 40 pvc pipe conforming to ASTM D3034.holes shall be placed facing down. 6. The complete Drainfield gravel and piping is to be covered with a geotextile filter fabric. Soil or combination of soil and extruded board insulation to a depth of 4' or equivalent is to be placed over the drainfield. Mounded side slopes shall not to exceed 3:1. The minimum insulation thickness shall be 2". Insulation shall be moa approved and rated for burial. 8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200' to any community well. Design Summary: MAX Excavation Depth: 8'(see cross section) Gravel Depth: 3' under distribution pipe, 2" over pipe. Sand Liner: 2' Drainfield Length: 80' (2@40) Drainfield Width: 5' Soil Rating: 0.45 gpd/sqft System Capacity: 2 Bedrooms Municipality of Anchorage Development Services Department Building Safety Division ~J' '~,.:;,~',o*_~*~*~*~*~*~*~*~_ ~,,..~..o.o.,~ .... On-Site Water and Wastewater Program 4700 E~more Road P.O. Box 196650 Anchorage, AK 99507 www. ci.anchoraqe.ak.us I ~... Soils Log - Percolation Test Pedormed For: JOHN ALBRECHT Date Pedormed:8/16/201~ Legal Description: RABBIT CREEK VIEW AND HTS B7H L29A Township, Range, Section: Slope Site Plan 1- 4- WAS GROUND WATER 9- ENCOUNTERED? YES S L 10- IF YES, AT WHAT DEPTH? 1~ O  Depth to Waler After 1 1- Monitoring? 1 1 P E ¢~/5 Dad: 8/25/16 13- 14- 15- 16- 17- 18- 19- 20- Reading Date Gross Time Net Time Depth to Water Net Drop 0 8/16/16 2:02 0 5 0 1 8/16/16 2:32 :30 5-7/16 9/16 2 8/16/16 2:35 0 5 0 3 8/16/16 3:05 :30 5-8/16 8/16 4 8/16/16 3:07 0 5 0 5 8/16/16 3:37 :30 5-8/16 8/16 8/16/16 PEP, COLATION RATE 60 (mfnutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN 4 FT AND5 FT COMMENTS 1' '10 2' OF NATIVE MATERIAL REMOVED FROM GROUND SURFACE AT PART OF SEPTIC LOCATION. PERC HOLE PRESOAKED OVERNIGHT, ~'?f~,EP~ ~".4-,¢~...zC,y£/~./C/>.P~./~-,r2.~ "re /~_~' 1~.~5 PERFORMED BY: CHARLES BALZARINI I CHARLES BALZARINI CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 8/'16/16 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 On -Site Water & Wastewater Program Fax: 907-343-7997 A real estate property owner (Owner) may install their own septic system. The department may issue an approval for a homeowner to perform work on a conventional (not AWWTS) on-site wastewater disposal system to serve that individual's owner -occupied, single-family or duplex home if the homeowner satisfies and agrees to the following requirements. The property owner and excavation equipment operator may perform work on no more than one owner installed project in a 12 -month period" As owner of (legal description) J_F 3 T Gl 7C Jteti/ 1��I�,Hi3 I a ree the following items are true and accurate. r= " g fc�"M Lr i�. �P j io 1247 1. My experience installing septic systems is as follows. t4p-vc IN 'T°lLE �j P''1lC �j�rj'j —ulS irJ OL CJ;[cU S cTC� �. Ca A L7Ec�1 G' �t5—JPi'r�Tu►� 1C�iiI /C ac•r 9`li`f S� 2. The name of the excavation equipment operator is. DA+J Eg&. 2 1, >4P. In 14A t 3. There will not be compensation for installation services rendered. 4. 1 will be actively involved with the septic system install tion at all times A Jc) W +Lt W Zfun�� `i_uS�L ( w� r+i �s+� a EN It f <�r D+Ji2 NCi Lai re i7 4�0 $t 5. The name of the inspecting engineer is GSM ✓; ie- 6. 1 agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.150. c. 2 -hour minimum advance notice given to the On-site Water & Wastewater Program for all required municipal inspections. 7. 1 agree any changes I make to the items listed above will require a new approval before performing work. I agree to have the project -specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. Owner's printed name: 01-0,J Owner's signature: Date: Septic System Owner Installer Agreement_Feb2015.doc